Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Grating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

An ultraviolet polarimeter for the Solar Maximum Mission

The Solar Maximum Mission experiment contingency will include one instrument originally designed and built for OSO-8. The engineering model of the OSO-8 High Resolution Spectrometer has been rebuilt to make it lightworthy and to encompass several new functions, including solar ultraviolet polarimetry. The rebuilt package is designated as the High Resolution Ultraviolet Spectrometer/Polarimeter. The device that enables polarimetry is a dual channel rotating waveplate system. The waveplates are magnesium fluoride and will allow measurements to be made ranging from the Lyman alpha line to near visible ultraviolet. One wavelength channel will use the polarization characteristics of the spectrometer diffraction grating as the analyzer. The second channel has a built-in four-mirror polarizer. This paper describes the polarimeter design, operation, and calibration.

Calvert, J.↗

High resolution spectrograph for the Space Telescope

The high resolution spectrograph (HRS) for ultraviolet astronomy with the Space Telescope will provide a spectral resolution of approximately 120,000 over a nominal wavelength range of 110-320 nm, together with a spatial resolution of about 0.25 arc seconds. The two detectors will consist of 512-element Digicons with cesium telluride and cesium iodide photocathodes, respectively. Photoelectrons in transit between the photocathodes and the diodes within the Digicons can be deflected in two axes with 12-bit resolution. This feature facilitates a design that emphasizes reliability since (once a hermetic seal is opened in orbit), only two moving parts, a grating carrousel and a shutter, are required for regular operation of the HRS. The instrument will be controlled by a computer in the spacecraft. The scientific objectives of the HRS investigation relate to interstellar matter in our own and nearby galaxies, physical processes of stellar mass loss and mass transfer, chemical abundances, bright quasars and Seyfert galaxy nuclei, and solar system phenomena.

Brandt, J. C.↗

Electrographic instrumentation for ultraviolet imaging and spectrography

The latest results in the NRL program of far-UV electrographic camera development, and application of these cameras to astrophysical and upper-atmospheric investigations, are presented. A new large electrographic Schmidt camera, of 15 cm aperture and f/2 focal ratio, has been successfully used in two sounding rocket flights, one for direct imagery in the 1230-2000 A wavelength range and the second for objective spectrography in the 950-2000 A range, of stars and nebulae in the Cygnus region of the sky. The camera has an 11 deg field of view and better than 30 arcsec resolution (2 A spectral resolution with 600 line/mm objective grating). A nebular spectrograph, based on a microchannel-intensified electrographic Schmidt camera, is the payload of a May 1979 rocket flight. It will reach emission line features as faint as 5 Rayleighs in 100 second exposures in the 1050-2000 A range, with 5 A spectral resolution.

Carruthers, G. R.↗

Some recent results in quiescent prominence spectrometry

This paper describes some recent results of a quiescent-prominence spectrometry program. The observations were made with a 25-cm coronagraph/coude spectrograph system using a silicon vidicon detector. This detector consists of 500 contiguous channels covering approximately 6 or 80 A, depending on the grating used. The instrument is interfaced to a computer system and has the important advantages of wide spectral response, linearity, and signal averaging with real-time display. Its principal drawback is the relatively small target size. For the present work, the aperture was about 3 x 5 arcsec. Absolute intensity calibrations were made by measuring quiet regions near the center of the sun.

Landman, D. A.↗

Iodine imaging using spectral analysis

Existing radiographic imaging systems provide images which represent an integration or averaging over the energy spectrum. In order to provide noninvasive angiography it is necessary to image the relatively small amounts of iodine which are available following an intravenous administration. This is accomplished by making use of the special spectral characteristics of iodine. Two methods will be presented. One involves a special grating for encoding the iodine information in the form of a fine line pattern. This is subsequently decoded to provide images of iodinated structures which are otherwise almost invisible. The second method utilizes a scanned X-ray beam which is rapidly switched in the high energy region. In this region, iodine experiences significant variations in the attenuation coefficient while bone and soft tissue do not. An efficient and accurate X-ray detector can be used with scanned X-ray beams. This provides a high degree of sensitivity enabling the visualization of small vessels containing relatively dilute iodine.

Macovski, A.↗

Computer modeling for a space power transmission system

The paper summarizes the development of a computer program that simulates the performance of a large phased array antenna composed of 7220 smaller subarrays, each made up of klystron modules which act as individual radiators. The purpose of this program is to: (1) study the far-field pattern near the rectenna, (2) calculate the beam efficiency, and (3) observe the grating lobe behavior. Attention is given to the computer program which consists of a main program and four subroutines, as well as to the system configurations. The effects of amplitude, phase and random subarray failures are examined and an error budget was specified for 10 to the 0 phase error, + or - 1 dB amplitude error, and a 2% random failure rate.

Rathjen, S. M.↗

Microwave system performance for a solar power satellite during startup/shutdown operations

The paper investigates the system performance and antenna characteristics under startup/shutdown conditions for the high power beam from a solar power satellite. Attention is given to the present microwave system reference configuration together with the dc power distribution system in the solar array and in the antenna. The pattern characteristics for the main beam, sidelobes, and grating lobes are examined for eight types of energizing configurations which include: random sequences, two types of concentric circles, and three types of line strips. In conclusion, it is noted that a proper choice of sequences should not cause environmental problems due to increased microwave radiation levels during the short time periods of energizing and de-energizing the antenna.

Arndt, G. D.↗

Image Properties of an X-Ray Telescope of the Wolter-1 Type with Emphasis on Contrast Reduction by Diffuse Reflection

Theoretical and experimental results are presented on the geometrical-optic imaging properties of a Wolter-1 type paraboloid-hyperboloid X-ray telescope. Particular consideration is given to the effect of microroughness of the mirror on the imaging properties. Experiments were conducted in which scattering properties were determined as a function of wavelength, incidence angle, and roughness of the plane mirrors. Results indicate the need for optimization of mirror material and polishing technology as well as the development of improved mirror manufacturing techniques. The use of transmission gratings along with the Wolter-1 type telescope in spectroscopy applications is discussed.

Lenzen, R.↗

Diagnostics and control of wavenumber stability and purity of tunable diode lasers relevant to their use as local oscillators in heterodyne systems

Initial operation of the tunable diode lasers (TDL) showed that it was not possible to adjust the wavenumber to one selected a priori in the TDL tuning range. During operation, the operating point would change by 0.1/cm over the longer term with even larger changes occurring during some thermal cycles. Most changes during thermal cycling required using lower temperatures and higher currents to reach the former wavenumber (when it could be reached). In many cases, an operating point could be selected by changing TDL current and temperature to give both the desired wavenumber and most of the power in a single mode. The selection procedure had to be used after each thermal cycling. Wavenumber nonlinearities of about 10% over a 0.5 cm tuning range were observed. Diagnostics of the single mode selected by a grating monochromator showed wavenumber fine structure under certain operating conditions. The characteristics due to the TDL environment included short term wavenumber stability, the instrument lineshape function, and intermediate term wavenumber stability.

Poultney, S.↗

Development and performance of a laser heterodyne spectrometer using tunable semiconductor lasers as local oscillators

A diode laser based IR heterodyne spectrometer for laboratory and field use was developed for high efficiency operation between 7.5 and 8.5 microns. The local oscillator is a PbSSe tunable diode laser kept continuously at operating temperatures of 12-60 K using a closed cycle cooler. The laser output frequency is controlled and stabilized using a high precision diode current supply, constant temperature controller, and a shock isolator mounted between the refrigerator cold tip and the diode mount. Single laser modes are selected by a grating placed in the local oscillator beam. The system employs reflecting optics throughout to minimize losses from internal reflection and absorption, and to eliminate chromatic effects. Spectral analysis of the diode laser output between 0 and 1 GHz reveals excess noise at many diode current settings, which limits the infrared spectral regions over which useful heterodyne operation can be achieved. System performance has been studied by making heterodyne measurements of etalon fringes and several Freon 13 (CF3Cl) absorption lines against a laboratory blackbody source. Preliminary field tests have also been performed using the Sun as a source.

Glenar, D.↗

Single-mode laser studies: Design and performance of a fixed-wave length source and coupling of lasers to thin-film optical waveguides

A module developed for the generation of a stable single wavelength to be used for a fiber optic multiplexing scheme is described. The laser is driven with RZ pulses, and the temperature is stabilized thermoelectrically. The unit is capable of maintaining a fixed wavelength within about 6 A as the pulse duty cycle is changed between 0 and 100 percent. This is considered the most severe case, and much tighter tolerances are obtainable for constant input power coding schemes. Using a constricted double heterostructure laser, a wavelength shift of 0.083 A mA is obtained due to laser self-heating by a dc driving current. The thermoelectric unit is capable of maintaining a constant laser heat-sink temperature within 0.02 C. In addition, miniature lenses and couplers are described which allow efficient coupling of single wavelength modes of junction lasers to thin film optical waveguides. The design of the miniature cylinder lenses and the prism coupling techniques allow 2 mW of single wavelength mode junction laser light to b coupled into thin film waveguides using compact assemblies. Selective grating couplers are also studied.

Ladany, I.↗

Video techniques in comet-debris studies

The paper describes techniques for examining comets and meteors. Data was obtained on four nights around the peak of the Geminid shower, using SEC Vidicon equipment at Mount Hopkins Observatory in Arizona at a latitude of 31 deg 41.9 north, longitude 110 deg 52.7 west, and 2320 meters above sea level. The TV employed, was mated to an f/0.75 lens of 105 mm focal length, and agove the lens a transmission diffraction grating was fixed with 300 lines/mm. Attention is given to the calibration curve of the seven-pixer means and to the contour lines drawn by the Image Data Processing System (IDAPS).

Millman, P. M.↗

Faint-object spectrograph for Space Telescope

The paper presents the Faint Object Spectrograph (FOS) for the Space Telescope to provide a digitized spectra of faint astronomical objects over the 115 to 700 nm wavelength range at resolving powers of 1000 and 100. A variety of concave gratings and prisms is employed to form nearly stigmatic spectra on one of the two Digicon photon counting detectors which are optimized for two different but overlapping ranges. The scientific goals associated with quasars, active galaxies, and objects within our solar system are discussed, and the FOS optical design features, including detectors, electronics, signal processing, power supplies, and data handling are examined. The FOS structural system, mechanism, and controls are described, along with the predicted performance capabilities in the spectral and spectropolarimetry modes. Finally, system performance parameters, including spatial resolution, time resolution, noise, and efficiency are discussed.

Harms, r. J.↗

X-ray spectrometer spectrograph telescope system

A new sounding rocket payload that has been developed for X-ray spectroscopic studies of the solar corona is described. The instrument incorporates a grazing incidence Rowland mounted grating spectrograph and an extreme off-axis paraboloic sector feed system to isolate regions of the sun of order 1 x 10 arc seconds in size. The focal surface of the spectrograph is shared by photographic and photoelectric detection systems, with the latter serving as a part of the rocket pointing system control loop. Fabrication and alignment of the optical system is based on high precision machining and mechanical metrology techniques. The spectrograph has a resolution of 16 milliangstroms and modifications planned for future flights will improve the resolution to 5 milliangstroms, permitting line widths to be measured.

Bruner, E. C., Jr.↗

Portable high-resolution laser monochromator-interferometer with multichannel electronic readout

A high-resolution 0.4-m monochromator is described for use in wavelength diagnosis of tunable pulsed and CW laser sources in the 3000-10,000-A region. The f/20 design uses an echelle grating in an over-and-under Ebert configuration with a scanned photodiode array to provide a real-time multichannel display of spectral output. Absolute wavelength may be determined to 0.1 A with the monochromator, and a Fabry-Perot interferometer attachment extends linewidth measurement capability to 0.01 A or better. Spectra are displayed on a storage oscilloscope, and calculation of laser parameters is explained. The instrument measures 70 cm long x 15 cm wide x 20 cm high.

Morris, M. B.↗

Photoelectric scanning /6.65-m/ spectrometer for VUV cross-section measurements

A 6.65-m normal incidence vacuum spectrograph has been provided with a photoelectric scanner that is easily interchangeable with the original plate holder. The scanner consists essentially of a photoelectric detector and an exit slit that scans mechanically along the focal surface while the grating and entrance slit remain stationary. The design and construction of the 6.65-m scanning spectrometer, which operates in the 120-300-nm wavelength region, are discussed. The wavelength resolution of 0.001 nm obtained photoelectrically is better than that of any existing vacuum monochromator. The performance of the instrument is illustrated with vacuum ultraviolet scans of the (1, 5) band of fourth positive system of CO in emission, and the (14, 0) band of the Schumann-Runge system of O2 in absorption.

Yoshino, K.↗

Rocket instrument for far-UV spectrophotometry of faint astronomical objects

A sensitive sounding rocket instrument for moderate (about 10-A) resolution far-UV (1160-1750-A) spectrophotometry of faint astronomical objects has been developed. The instrument employes a photon-counting microchannel plate imaging detector and a concave grating spectrograph behind a 40-cm Dall-Kirkham telescope. A unique remote-control pointing system, incorporating an SIT vidicon aspect camera, two star trackers, and a tone-encoded command telemetry link, permits the telescope to be oriented to within 5 arc sec of any target for which suitable guide stars can be found. The design, construction, calibration, and flight performance of the instrument are discussed.

Hartig, G. F.↗

Densities and mass motions in transition-zone plasmas in solar flares observed from Skylab

The electron densities and bulk motions in the transition-zone plasma of a solar flare are investigated by an analysis of EUV emission line spectra taken on Skylab. Spectra of three flares were obtained with the NRL normal incidence grating slit spectrograph in the ranges 1100-1940 and 1940-3940 A. The line ratios of transition-zone Si III lines and the intensity of the forbidden O IV 1401-A lines during flare maximum indicate electron densities on the order of 10 to the 12th/cu cm, decreasing by a factor of 2 to 3 in the flare decay phase. Line broadening of the transition-zone ions such as Si III, O IV, C IV and N V is noted, and the observed asymmetrical N V line profiles are approximated by a bi-Gaussian model of a stationary and a moving plasma component with a bulk velocity of 12 to 70 km/sec. Turbulent velocities of from 45 to 85 km/sec and from 20 to 40 km/sec are also indicated for the moving and stationary components of the transition-zone plasma, respectively.

Cheng, C.-C.↗