Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Floating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Shear flow and drift wave turbulence dynamics in a cylindrical plasma device

The experimental observations of the dynamics of the coupled drift wave turbulence (DWT)/sheared zonal flow (ZF) system in a cylindrical plasma device using a combination of Langmuir probe and fast-framing imaging measurements are reported. The results show the presence of an azimuthal ZF that exhibits low frequency (approx250 Hz) fluctuations. The envelope of the higher frequency (above 5 kHz) floating potential fluctuations associated with the DWT, the density gradient, and the turbulent radial particle flux are all modulated out of phase with the strength of the ZF. The divergence of the turbulent Reynolds stress is also modulated at the same slow time scale in a phase-coherent manner consistent with a turbulent-driven shear flow sustained against the collisional and viscous damping. The radial turbulence correlation length and cross-field particle transport are reduced during periods of strong flow shear. The results are qualitatively consistent with theoretical expectations for coupled DWT-ZF dynamics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

LARGE SCALE REFRIGERATION PLANT FOR GROUND TESTING THE JAMES WEBB TELESCOPE AT NASA JOHNSON SPACE CENTER

The James Webb Telescope is the successor to the Hubble Telescope and will be placed in an orbit of 1.5 million km from earth. Before launch in 2014, the telescope will be tested in NASA Johnson Space Center's (JSC) space simulation chamber, Chamber A. The tests will be conducted at deep space conditions. Chamber A's helium cryo-panels are currently cooled down to 20 K by two Linde 3.5 kW helium refrigerators. The new 12.5 kW, 20-K helium coldbox described in this paper is part of the upgrade to the chamber systems for this large test program. The Linde coldbox will provide refrigeration in several operating modes where the temperature of the chamber is being controlled with a high accuracy due to the demanding NASA test requirements. The implementation of two parallel expansion turbine strings and the Ganni cycle—Floating Pressure process results in a highly efficient and flexible process that minimizes the electrical input power. This paper will describe the collaboration and execution of the coldbox project.

42 ENGINEERING↗

Measurement of electron temperature and ion density using the self-bias effect in plasmas

For novel plasma diagnostics, the rf floating probe was revisited. For inducing the self-bias effect, ac bias voltage (approxkilohertz) was applied through a dc blocking capacitor between a probe and a signal generator. The dc self-bias potential was changed not only with ac bias voltages but also with electron temperatures, and therefore, the electron temperature was derived from the variations in the self-bias potential with and without ac bias voltage. The harmonic component of the probe contains information about the ion flux, and using a fast Fourier transform analysis of the probe current, the ion density was derived from the first harmonic current of the probe. The experimental results were compared with a single Langmuir probe. The electron temperature and the ion density were in good agreement with those from the Langmuir probe. Because the amplitude of the ac bias voltage is very low (<3 V), local ionizations affected by a high bias-voltage can be neglected.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental investigation of edge-to-center density ratio in inductively coupled plasmas

Edge-to-center density ratios were measured by using a floating harmonics method in inductively coupled plasma (ICP) and were compared to the theoretical model. As the gas pressure increased, the plasma density at the center increased. However, plasma density at the edge showed a different trend; it had a maximum value at 10 mTorr with increasing gas pressures, regardless of ICP powers. This unexpected result could be explained by a global power balance equation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Drift-Alfven waves induced optical emission fluctuations in Aditya tokamak

In Aditya tokamak [S. B. Bhatt et al. Indian J. Pure Appl. Phys. 27, 710 (1989)], an increase in the H{sub a}lpha and C{sup 2+} intensity fluctuations from the edge region is observed with an increase in the magnetohydrodynamic (MHD) activity. Very small fluctuation amplitudes of H{sub a}lpha and C{sup 2+} intensity are observed in discharges where there is no MHD activity compared to the discharges with MHD activity. These fluctuations in the H{sub a}lpha and C{sup 2+}, measured by optical filter--photomultiplier tube combination--are modulated by Mirnov oscillations having a dominant peak with a common frequency approx7-10 kHz. Further investigation reveals the presence of strong coherent fluctuations in density and floating potential at same frequency as well. These observations indicate the existence of a nonelectrostatic instability, which may be based on the coupled mode of the drift mode and the Alfven mode. The coherent density fluctuations give rise to the experimentally observed coherent H{sub a}lpha and C{sup 2+} intensity fluctuations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Potential formation in front of an electron emitting electrode immersed in a plasma that contains a monoenergetic electron beam

A one-dimensional fluid model of the sheath formation in front of a large, planar electron emitting electrode (collector) immersed in a plasma that contains a monoenergetic electron beam is presented. Expressions for the Bohm criterion, the total electric current to the collector, and for the zero electric field at the collector are derived. When there is no electron emission, the model predicts, in some cases, up to three different solutions. The low and the high solutions correspond to the fact that the presheath potential drop can be determined either by thermal or by the beam electrons. The middle solution between them has no physical meaning. When the electron emission is space charge limited, the model may have up to five solutions because the low solution can sometimes split into three parts. The current-voltage characteristic of the collector that exhibits triple floating potential is calculated and it shows qualitative similarity with experimental ones [C.-H. Nam et al., J. Appl. Phys. 63, 5674 (1988)]. When the emission is below the space charge limit, the model again exhibits up to five solutions, which are the low, middle, high, and two additional 'singularity solutions'. These two appear because of the singularity in the Bohm criterion. Regions of validity of the low and high solutions are determined from numerical solutions of the Poisson equation [T. Gyergyek et al., Plasma Sources Sci. Technol. 18, 035001 (2009)] and with the maximum positive ion flux test [J. I. Fernandez Palop et al., J. Appl. Phys. 91, 2587 (2002)]. In the case of no or small emission, both methods give the same results. If the emission is space charge limited, the numerical solution method is much more reliable.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dust jets produced by a dust-discharge instability

We report observations of an instability that occurs in a dc glow discharge (anodic plasma) dusty plasma when a floating plate with a 5 mm aperture is placed in front of the anode. The instability is characterized by periodic quenching and reignition of the discharge. When the discharge is quenched, the dust is ejected from the aperture at speeds on the order of the dust-acoustic speed. The ejected dust remains partially charged and retracts back to the aperture when the discharge spontaneously redevelops.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A new large area lanthanum hexaboride plasma source

A new 18x18 cm{sup 2} active area lanthanum hexaboride (LaB{sub 6}) plasma source for use in a dc discharge has been developed at UCLA. The cathode consists of four tiled LaB{sub 6} pieces indirectly heated to electron emission (1750 deg. C) by a graphite heater. A molybdenum mesh anode 33 cm in front of the LaB{sub 6} accelerates the electrons, ionizing a fill gas to create a 20x20 cm{sup 2} nearly square plasma. The source is run in pulsed operation with the anode biased up to +400 V dc with respect to the cathode for up to 100 ms at a 1 Hz repetition rate. Both the cathode and anode ''float'' electrically with respect to the chamber walls. The source is placed in a toroidal chamber 2 m wide and 3 m tall with a major radius of 5 m. Toroidal and vertical magnetic fields confine the current-free plasma which follows the field in a helix. The plasma starts on the bottom of the machine and spirals around it up to four times (120 m) and can be configured to terminate either on the top wall or on the neutral gas itself. The source typically operates with a discharge current up to 250 A in helium making plasmas with T{sub e}<30 eV, T{sub i}<16 eV, and n{sub e}<3x10{sup 13} cm{sup -3} in a background field of 100 G<B{sub o}<320 G, giving a magnetized plasma with 0.1<{beta}<1.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Potential High Resolution Dosimeters For MRT

Microbeam Radiation Therapy (MRT) uses highly collimated, quasi-parallel arrays of X-ray microbeams of 50-600 keV, produced by 2nd and 3rd generation synchrotron sources, such as the National Synchrotron Light Source (NSLS) in the U.S., and the European Synchrotron Radiation Facility (ESRF) in France, respectively. High dose rates are necessary to deliver therapeutic doses in microscopic volumes, to avoid spreading of the microbeams by cardiosynchronous movement of the tissues. A small beam divergence and a filtered white beam spectrum in the energy range between 30 and 250 keV results in the advantage of steep dose gradients with a sharper penumbra than that produced in conventional radiotherapy. MRT research over the past 20 years has allowed a vast number of results from preclinical trials on different animal models, including mice, rats, piglets and rabbits. Microbeams in the range between 10 and 100 micron width show an unprecedented sparing of normal radiosensitive tissues as well as preferential damage to malignant tumor tissues. Typically, MRT uses arrays of narrow ({approx}25-100 micron-wide) microplanar beams separated by wider (100-400 microns centre-to-centre, c-t-c) microplanar spaces. We note that thicker microbeams of 0.1-0.68 mm used by investigators at the NSLS are still called microbeams, although some invesigators in the community prefer to call them minibeams. This report, however, limits it discussion to 25-100 {mu}m microbeams. Peak entrance doses of several hundreds of Gy are surprisingly well tolerated by normal tissues. High resolution dosimetry has been developed over the last two decades, but typical dose ranges are adapted to dose delivery in conventional Radiation Therapy (RT). Spatial resolution in the sub-millimetric range has been achieved, which is currently required for quality assurance measurements in Gamma-knife RT. Most typical commercially available detectors are not suitable for MRT applications at a dose rate of 16000 Gy/s, micron resolution and a dose range over several orders of magnitude. This paper will give an overview of all dosimeters tested in the past at the ESRF with their advantages and drawbacks. These detectors comprise: Ionization chambers, Alanine Dosimeters, MOSFET detectors, Gafchromic registered films, Radiochromic polymers, TLDs, Polymer gels, Fluorescent Nuclear Track Detectors (Al{sub 2}O{sub 3}:C, Mg single crystal detectors), OSL detectors and Floating Gate-based dosimetry system. The aim of such a comparison shall help with a decision on which of these approaches is most suitable for high resolution dose measurements in MRT. The principle of these detectors will be presented including a comparison for some dosimeters exposed with the same irradiation geometry, namely a 1x1 cm{sup 5} field size with microbeam exposures at the surface, 0.1 cm and 1 cm in depth of a PMMA phantom. For these test exposures, the most relevant irradiation parameters for future clinical trials have been chosen: 50 micron FWHM and 400 micron c-t-c distance. The experimental data are compared with Monte Carlo calculations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Potential structure around the Cassini spacecraft near the orbit of Enceladus

We present the results of numerical simulations of the potential structure around an object in a streaming plasma with parameters relevant for the Cassini spacecraft passing through Saturn's plasma disk near the orbit of Enceladus. Two- and three-dimensional particle-in-cell codes have been used allowing the potential of the simulated spacecraft body to develop self-consistently through the collection of charge by its surface. The dependence of the density and potential profiles on ambient plasma density, electron temperature, and ion drift speed is discussed. The spacecraft floating potential values, found in the simulations, are compared to those deduced from the analysis of Cassini Langmuir probe characteristics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Biasing, acquisition, and interpretation of a dense Langmuir probe array in NSTX

A dense array of 99 Langmuir probes has been installed in the lower divertor region of the National Spherical Torus Experiment (NSTX). This array is instrumented with a system of electronics that allows flexibility in the choice of probes to bias as well as the type of measurement (including standard swept, single probe, triple probe, and operation as passive floating potential and scrape-off-layer SOL current monitors). The use of flush-mounted probes requires careful interpretation. The time dependent nature of the SOL makes swept-probe traces difficult to interpret. To overcome these challenges, the single- and triple-Langmuir probe signals are used in complementary fashion to determine the temperature and density at the probe location. A comparison to midplane measurements is made.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cr-doped TiO{sub 2} (rutile): Ferromagnetism in bulk form?

Cr-doped rutile samples in powder and single crystal form have been prepared and studied with particular emphasis on their compositional, structural, and magnetic properties. Both powders and single crystals were characterized using x-ray diffractometry and vibrating sample magnetometry, while crystals were also studied using the x-ray Laue technique, scanning electron microscopy, and energy dispersive x-ray analysis. The results indicate weak ferromagnetic behavior at room temperature (RT) in Cr-doped TiO{sub 2} powders having 2 at. % Cr, while powders with higher amounts of Cr (e.g., 8 or 12 at. %) showed no evidence of ferromagnetism. Following successful floating zone crystal growth of Cr-doped rutile crystals in argon, magnetic measurements taken from the as-grown crystals revealed no indication of RT ferromagnetism over the composition range 2 to 12 at. % Cr. A solubility limit for Cr into the rutile matrix of 3 at. % Cr at RT is suggested.

36 MATERIALS SCIENCE↗

Multichannel Langmuir probe for turbulence study in Heliotron J

New multichannel Langmuir probe system was developed and installed to Heliotron J. The objective of the new probe is to characterize basic turbulence property and the resulting transport in advanced helical configuration. The probe developed here consists of four sets of triple probe and one pin for floating potential measurement. Initial experiments in neutral beam heating plasma were conducted and fluctuation profile of radial and poloidal electric fields and Reynolds stress were estimated. For precise evaluation of the electric fields and Reynolds stress, a technique to compensate radial change of tilt angle between probe array and magnetic surface was proposed and applied to the initial results obtained in edge region of Heliotron J where the complicated magnetic structure exists.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Central Difference Interval Method for Solving the Wave Equation

This paper presents path of construction the interval method of second order for solving the wave equation. Taken into consideration is the central difference interval method for one-dimensional partial differential equation. Numerical results, obtained by two presented algorithms, in floating-point interval arithmetic are considered.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Novel Solid Electrolyte Oxygen Sensor System for In-Situ Measurement and Process Control

In 1993 the oxygen partial pressure was firstly measured inside a plasma wind tunnel using conventional {lambda}-probes. Since then, a considerable amount of knowledge has been gained in using these sensors in ground test facilities and space. However, these commercially available sensors were too large in scale and weight. Consequently, a new development of solid electrolyte sensors called FIPEX more feasible for space was initiated. Due to space driven benefits, interest arose to use FIPEX technique in terrestrial applications e.g. to monitor sputter plants for float glass coating. Therefore, the VacuSen registered sensor was developed. The characterization of VacuSen registered at nominal sensor temperature T{sub S} = 680 deg. C resulted in a sensor current according to I{sub S} = b{center_dot}p{sub O2}{sup 0{center_dot}8{+-}0{center_dot}05} I[{mu}A] in the operation range between p{sub tot} = 1{center_dot}10{sup -3} to 5 Pa. From pulse width modulation (PWM) temperature control, additional information allows to measure ptot according to p{sub tot} = a{center_dot}RPWM{sup 0{center_dot}107{+-}0{center_dot}005} thus enlarging the operation range to p{sub tot} = 1{center_dot}10{sup -3} to 1{center_dot}10{sup 5} Pa. A one point calibration routine with air, ideally at p{sub tot} = 5 Pa in order to determine both calibration parameters a and b simultaneously, is proposed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A numerical method for determining highly precise electron energy distribution functions from Langmuir probe characteristics

Electron energy distribution functions (EEDFs) were determined from probe characteristics using a numerical ac superimposed method with a distortion correction of high derivative terms by varying amplitude of a sinusoidal perturbation voltage superimposed onto the dc sweep voltage, depending on the related electron energy. Low amplitude perturbation applied around the plasma potential represented the low energy peak of the EEDF exactly, and high amplitude perturbation applied around the floating potential was effective to suppress noise or distortion of the probe characteristic, which is fatal to the tail electron distribution. When a small random noise was imposed over the stabilized prove characteristic, the numerical differentiation method was not suitable to determine the EEDF, while the numerical ac superimposed method was able to obtain a highly precise EEDF.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electrical double layers at shock fronts in glow discharges and afterglows

This paper examines the propagation of spark-generated shockwaves (1.0<Mach<2.0) into argon and nitrogen glow discharges and their afterglow. Diagnostic methods were employed and expanded in order to capture the dynamics of the shock front in these weakly-ionized, nonmagnetized, collisional plasmas. We used a microwave hairpin resonator to measure the electron number density, and, for all cases, we measured an increase in the electron number density at the shock front. By comparing the increase in electron number density at the shock front in the active discharge and in the afterglow, we conclude that electrons with a temperature much greater than room temperature can be compressed at the shock front. The ratio of electron number density before and after the shock front can be approximately predicted using the Rankine-Hugoniot relationship. The large gradient in electron density, and hence a large gradient in the flux of charged species, created a region of space-charge separation, i.e., a double layer, at the shock front. The double layer balances the flux of charged particles on both sides of the shock front. The double layer voltage drop was measured in the current-carrying discharge using floating probes and compared with previous models. As well, we measured argon 1s{sup 5} metastable-state density and demonstrate that metastable-state neutral species can be compressed across a shock front and approximately predicted using the Rankine-Hugoniot relationship.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spherical plasma oscillations in a reversed-polarity inertial-electrostatic confinement device

A pulsed reversed-polarity inertial-electrostatic confinement device has been investigated experimentally using voltage and spectroscopic diagnostics. Large-amplitude oscillations were observed in the floating potential of the plasma immediately following the initiation of the discharge. It is postulated that the observations were the result of coherent ion oscillations within a harmonic potential well formed by a uniform electron density in the center of the device. A simple model of the system predicts the depth of this transient potential well to be approximately 100 V. Observations of the relative occupation of the third and fourth energy levels of hydrogen in the plasma indicated the formation of a Maxwellian electron energy distribution after 20 {mu}s. The results suggest a promising avenue toward a net fusion power gain by utilizing these oscillations to periodically compress and heat the plasma to thermonuclear densities and energies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗