Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fire”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Evaluation of electroexplosive devices by nondestructive test techniques and impulsive waveform firings

Special requirements of the space industry for more detailed knowledge of the quality and reliability of each electroexplosive device (EED) selected for use aboard a spacecraft are described. Statistical methods do not practically demonstrate the high reliability needed. To close this gap, nondestructive test techniques and instrumentation for 1-W/1-A no-fire devices have been developed. Several lots of squibs have been evaluated using these techniques and instrumentation. They yield data as to the quality and normal behavior of each electroexplosive device without firing or degrading the unit. Performance data were obtained by initiating the EED's with an impulsive waveform and sensing the initiation characteristics, sensitivity, and output.

Menichelli, V. J.↗

Systematic control of nonmetallic materials for improved fire safety

The elements of a systematic fire safety program are summarized and consist of fire safety criteria, design considerations, testing of materials, development of nonmetallic materials, nonmetallic materials information systems, design reviews, and change control. The system described in this report was developed for the Apollo spacecraft. The system can, however, be tailored to many industrial, commercial, and military activities.

Source record↗

Flash and fire test: Evaluation of the behavior of nonmetallic materials in hydrogen

Tests conducted to evaluate the behavior of nonmetallic materials in hydrogen are described. The results of the flash and fire test are presented. The flash and fire test is used to evaluate the tendency of heated materials to ignite in a hydrogen atmosphere when subjected to an ignition source. The test represents a hydrogen parallel to a hazard condition known to exist in oxygen systems. Ten nonmetallic materials were evaluated to establish baseline data on the behavior of the materials and to characterize one mode of material failure considered to be a factor pertinent to the safe use of a material in hydrogen.

Source record↗

Operation and maintenance, fire rescue air-pack. Volume 2: Communications

The operation and maintenance procedures are described for the development model of the fire rescue air pack (FRAP) voice amplifier assembly, including the battery charger. Operational instructions include a general description of the assembly, specifications, and installation and operation. Maintenance instructions include theory of operation, preventive maintenance, repair, adjustment, and a parts list. The FRAP is intended to permit fire rescue personnel to enter a smoke-filled, toxic or oxygen depleted environment carrying their own source of breathing air. The voice amplifier assembly permits the wearer to communicate by voice with other persons in the vicinity. The battery charger assembly provides a means of keeping the amplifier batteries fully charged.

Source record↗

The application of an ultraviolet sensitive fire detector in a manned space vehicle.

Description of a detector which is sensitive to the ultraviolet molecular emissions of flames and has been selected as the basic element of the NASA Skylab fire-detection system. This detector is sensitive to approximately 10 to the minus 12th watts of ultraviolet radiation and will detect small flames at distances in excess of three meters. Its response to a variety of burning spacecraft materials has been investigated both in one-gravity and zero-gravity. The results of experiments conducted in an aircraft flying zero-gravity parabolas in an attempt to simulate the characteristics of a fire which the detector must sense are cited.

Linford, R. M. F.↗

Proceedings of the NASA Conference on Materials for Improved Fire Safety

The Manned Spacecraft Center was pleased to host the NASA Conference on Materials for Improved Fire Safety which was held on May 6 and 7, 1970. This document is a compilation of papers presented at the conference and represents the culmination of several years of effort by NASA and industry which was directed toward the common objective of minimizing the fire hazard in manned spacecraft and in some other related areas. One of the more serious problem areas in the Apollo program was the flammability of nonmetallic materials. The effective and timely solution of this problem area resulted from much of the effort reported herein and contributed greatly toward the successful achievement of landing men on the moon and returning them safely to earth.

Source record↗

Fail-safe fire detection system

Fire detection control system continually monitors its own integrity, automatically signals any malfunction, and separately signals fire in any zone being monitored. Should be of interest in fields of chemical and petroleum processing, power generation, equipment testing, and building protection.

Bloam, E. T.↗

Fire-resistant aircraft materials development and evaluation program

The overall objectives of this program are to provide a more fire-resistant commercial aircraft interior and to improve the fuselage insulation barrier between the cabin interior and an exterior fuel fire. Significant secondary objectives are to reduce the smoke and toxic gas production of the materials and to meet the end item use requirements pertaining to wearability, color fastness, and aesthetic appeal. It is shown that the fuselage insulation materials must meet stringent requirements pertaining to acoustic attenuation, low density, and water repellency.

Bricker, R. W.↗

Development of lightweight fire retardant, low-smoke, high-strength, thermally stable aircraft floor paneling

Fire resistance mechanical property tests were conducted on sandwich configurations composed of resin-fiberglass laminates bonded with adhesives to Nomex honeycomb core. The test results were compared to proposed and current requirements for aircraft floor panel applications to demonstrate that the fire safety of the airplane could be improved without sacrificing mechanical performance of the aircraft floor panels.

Arnold, D. B.↗

A composite system approach to aircraft cabin fire safety

The thermochemical and flammability characteristics of two polymeric composites currently in use and seven others being considered for use as aircraft interior panels are described. The properties studied included: (1) limiting oxygen index of the composite constituents; (2) fire containment capability of the composite; (3) smoke evolution from the composite; (4) thermogravimetric analysis; (5) composition of the volatile products of thermal degradation; and (6) relative toxicity of the volatile products of pyrolysis. The performance of high temperature laminating resins such as bismaleimides is compared with the performance of phenolics and epoxies. The relationship of increased fire safety with the use of polymers with high anaerobic char yield is shown. Processing parameters of one of the baremaleimide composites are detailed.

Kourtides, D. A.↗

An Investigation of Size-Dependent Concentration of Trace Elements in Aerosols Emitted from the Oil-Fired Heating Plants

Aerosols emitted from two oil-fired heating plants were aerodynamically separated into eight size groups and were analyzed using the photon-induced X-ray emission (PIXE) technique. It was found that Zn, Mo, Ag, and Pb, and (to a lesser extent) Cd, have a tendency to concentrate preferentially on the smaller aerosols. All of these elements, in certain chemical forms, are known to be toxic. Zinc and molybdenum, although present in low concentrations in the parent fuels, show the strongest tendencies to be concentrated in finer aerosols. Selenium, previously reported to show a very strong tendency to concentration in finer fly ash from coal-fired power plants shows little preference for surface residence. Vanadium, which occurs in significant concentration in the oil fuels for both plants, also shows little preference for surface concentration. Even though the absolute concentrations of the toxic elements involved are well below the safety levels established by the National Institute for Occupational Safety and Health (NIOSH), it would be advisable to raise the heights of the heating-plant exhaust chimneys well above the neighborhood buildings to insure more efficient aerosol dispersal.

Singh, J. J.↗

Mathematical model of fires

Model allows predictions of future development of fire and can be used to evaluate different control methods at particular stages of fire. Five constraints considered are flame-spread rate, fuel-surface limit, airflow limit, quantity of fuel, original quantity of air.

Coulbert, C. D.↗

Gaseous emissions and toxic hazards associated with plastics in fire situations: A literature review

The hazards of plastics in fire situations, the gases emitted, the factors influencing the nature of these emissions, the characteristics of toxic gases, and the results of laboratory studies, are discussed. The literature pertaining to the pyrolysis and oxidation of plastics was reviewed. An effort was made to define the state of the art for determining the toxic gases emitted by plastics under fire conditions. Recommendations are made and research needs defined as a result of this review.

Junod, T. L.↗

Materials research for aircraft fire safety

The thermochemical and flammability characteristics of two polymeric composites currently in use and seven others being considered for use as aircraft interior panels are described. The properties studied included: (1) limiting oxygen index of the composite constituents; (2) fire containment capability of the composite; (3) smoke evolution from the composite; (4) thermogravimetric analysis; (5) composition of the volatile products of thermal degradation; and (6) relative toxicity of the volatile products of pyrolysis. The performance of high-temperature laminating resins such as bismaleimides is compared with the performance of phenolics and epoxies. The relationship of increased fire safety with the use of polymers with high anaerobic char yield is shown. Processing parameters of the state-of-the-art and the advanced bismaleimide composites are detailed.

Kourtides, D. A.↗

Study of coatings for improved fire and decay resistance of mine timbers

The purpose of this program was to find a fire- and rot-retardant polymer/fungicide reaction product for coating mine timbers. Fire-retardant polymers were screened as films and coatings on fir wood. Curable polyimide appeared to be flame retardant and evolved a minimum of fumes when exposed to a flame. Several organic and metal, low toxicity, fungicides were reacted with the polyimide in-situ on the wood. These coated samples were screened for fungus resistance. All formulations rated well - even the polyimide film without additives was fungicidal. The fir wood control itself resisted internal damage during the ten weeks of fungus exposure. A more severe test for fungus resistance will be required.

Baum, B.↗

System studies of coal fired-closed cycle MHD for central station power plants

This paper presents a discussion of the closed cycle MHD results obtained in a recent study of various advanced energy conversion (ECAS) power systems. The study was part of the first phase of this ECAS study. Since this was the first opportunity to evaluate the coal fired closed cycle MHD system, a number of iterations were required to partially optimize the system. The present paper deals with the latter part of the study in which the direct coal fired, MHD topping-steam bottoming cycle was established as the current choice for central station power generation. The emphasis of the paper is on the background assumptions and the conclusions that can be drawn from the closed cycle MHD analysis. The author concludes that closed cycle MHD has efficiencies comparable to that of open cycle MHD and that both systems are considerably more efficient than the other system studies in Phase 1 of the GE ECAS. Its cost will possibly be slightly higher than that of the open cycle MHD system. Also, with reasonable fuel escalation assumptions, both systems can produce lower cost electricity than conventional steam power plants. Suggestions for further work in closed cycle MHD components and systems is made.

Zauderer, B.↗

Systems for animal exposure in full-scale fire tests

Two systems for exposing animals in full-scale fire tests are described. Both systems involve the simultaneous exposure of two animal species, mice and rats, in modular units; determination of mortality, morbidity, and behavioral response; and analysis of the blood for carboxyhemoglobin. The systems described represent two of many possible options for obtaining bioassay data from full-scale fire tests. In situations where the temperatures to which the test animals are exposed can not be controlled, analytical techniques may be more appropriate than bioassay techniques.

Hilado, C. J.↗