Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Finite Element Modelling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Critical Evaluation of a Novel Analysis Technique for Assessment of Printed Circuit Heat Exchangers in High-Temperature Nuclear Service

Application of printed circuit heat exchangers (PCHEs) to very high-temperature reactors (VHTRs) requires mechanical performance assessment methodologies. The PCHE morphology consists of thousands of millimeter-scale channels, for enhanced thermal efficiency, enclosed in a meter-scale PCHE core. PCHE geometry under thermomechanical creep-fatigue transients results in multi-axial interactions between its different segments, such as channeled core, walls, and headers. These global-level interactions influence the local channel-level responses. Hence, developing a PCHE performance assessment methodology, following the ASME Code, Section III, Division 5 provisions, is a critical gap to be filled. There is no analysis or design methodology available in ASME Code to assess a PCHE for its global and local level performances under high temperature and pressure loadings. This paper critically evaluates a recently proposed two-step analysis technique to estimate global interactions and local channel-level responses of PCHEs. In this novel analysis technique, the channeled PCHE core is replaced with orthotropic solid blocks of representative stiffness properties for the global thermomechanical analysis. Here, subsequent channel scale submodel analysis with detailed channel geometry, loading, and elastic-perfectly plastic (EPP) material model estimates the local responses for PCHE performance assessment. This paper critically evaluates this novel technique for its effectiveness in PCHE performance assessment. Finite element (FE) models imitating various analysis issues are developed, and FE analysis results are scrutinized. An important outcome of this study is the validation of the novel two-step PCHE analysis technique for application to the performance assessment of PCHEs in VHTRs.

42 ENGINEERING↗

Crystal plasticity modeling for the strengthening effect of multilayered copper–graphene nanocomposites

The paper explores plastic deformation mechanisms in metal–graphene nanocomposites, illustrating their material strengthening effects through a crystal plasticity finite element (CPFE) model. This model is compared with published experimental results, which have previously shown that the two-dimensional shape of graphene effectively controls dislocation motion and significantly enhances the strength of metals. Simulated nanopillar compression tests, using a physics-based CP model that incorporates surface nucleation and single-arm source dislocation mechanisms, help us understand dislocation motions at submicron length scales. The crystal plasticity models are applied to nanolayered composites with copper grain layers and monolayer graphene, featuring repeat layer spacings of 200 nm, 125 nm, and 70 nm, respectively. This study quantifies the accumulation of dislocations at the graphene interfaces, contributing to the ultra-high strength of copper–graphene composites. Furthermore, a Hall–Petch-like correlation is established between yield strength and the number of embedded graphene layers.

36 MATERIALS SCIENCE↗

Modeling of coal stockpiles using a finite elements method

In the case of coal stockpiles finding suitable environmental conditions, spontaneous combustion phenomenon will be unavoidable. In this study, an industrial-sized stockpile having a shape of triangle prism was constituted in a coal stockyard of Western Lignite Corporation (WLC), Turkey. The parameters of time, humidity and temperature of air, atmospheric pressure, velocity and direction of wind values that are effective on coal stockpile were measured in a continuous manner. These experimental works were transferred into a computer media in order to obtain similar outcomes by carrying out 2-dimensional analysis of the stockpile with Finite Elements Method (FEM). The performed experimental studies and obtained results were then compared.

01 COAL, LIGNITE, AND PEAT↗

Numerical and Experimental Investigations of Polyurethane Foam for Use as Cask Impact Limiter in Accidental Drop Scenarios - 12099

Rigid, closed-cell polyurethane foams are frequently used as cask impact limiters in nuclear materials and hazardous waste transport due to their high energy-absorption potential. When assessing the cask integrity in accidental scenarios based on numerical simulations, a description of the foam damping properties is required for different strain rates and for a wide temperature range with respect to waste heat generation in conjunction with critical operating and environmental conditions. Implementation and adaption of a respective finite element material model strongly relies on an appropriate experimental data base. Even though extensive impact experiments were conducted e.g. in Sandia National Laboratories, Savannah River National Laboratory and by Rolls Royce plc, not all relevant factors were taken into account. Hence, BAM who is in charge of the mechanical evaluation of such packages within the approval procedure in Germany, incorporated systematic test series into a comprehensive research project aimed to develop numerical methods for a couple of damping materials. In a first step, displacement driven compression tests have been performed on confined, cubic specimens at five loading rates ranging from 0.02 mm/s to 3 m/s at temperatures between +90 deg. C and -40 deg. C. Materials include two different polyurethane foam types called FR3718 and FR3730 having densities of 280 kg/m{sup 3} and 488 kg/m{sup 3} from the product line-up of General Plastics Manufacturing Company. Their data was used to adapt an advanced plasticity model allowing for reliably simulating cellular materials under multi-axial compression states. Therefore, an automated parameter identification procedure had been established by combining an artificial neural network with local optimization techniques. Currently, the selected numerical material input values are validated and optimized by means of more complex loading configurations with the prospect of establishing methods applicable to impact limiters under severe accidental conditions. The reference data base is provided by experiments, where weights between 212 kg and 1200 kg have been dropped from heights between 1.25 m and 7 m on confined 10 cm cubic foam specimens. By presenting the deviations between experimental values and the corresponding output of finite element simulations, the potentials and restrictions of the resulting models are highlighted. Systematic compression tests on polyurethane foams had been performed at BAM test site within the framework of a research project on impact limiters for handling casks for radioactive waste. The experimental results had been used to adapt numerical models for simulating the behaviour of different foam types at different temperatures. The loading speed, however, turned out to have a major influence on their flow curves that can not be captured by simple strain-rate dependent multipliers. Especially for guided drop tests that come close to real accidental scenarios there is a significant gap between experimental and numerical results even when applying such advanced material models. Hence, the extensive data base is currently deployed for expanding the standard algorithms to include adequate dynamic hardening factors. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A method to determine the onset voltage of single and arrays of electrospray emitters

This paper reports on an accurate and rapid method to compute the onset voltage of a single or an array of electrospray emitters with complex geometries and on the correlation of the simulation with experimental data. This method permits the exact determination of the onset voltage based only on the surface tension of the sprayed liquid and on the emitter geometry. The approach starts by determining the voltage at which electrostatic forces and surface tension forces are equal for a sharpening conic surface at the tip of a capillary as a function of the apex radius of the liquid. By tracing the curve of this computed equilibrium voltage as a function of the apex radius, the onset voltage for a liquid surface with the Taylor half-angle of 49.3 deg. or larger can be determined. For smaller cone half-angles the method is only applicable to ionic sprays as an approximate knowledge of the critical field for ion emission is necessary. The combination of analytical models and finite element tools used to compute the necessary parameters is described. The method is validated on a complex microelectromechanical system emitter geometry as well as on a linear array of electrospray emitters. Finally an empirical model of the behavior of the electric field near the apex of a conic surface with asymptotes at a fixed half-angle is proposed, which allows establishing a simple method for onset voltage determination.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Validation of the Modelling of Corrosion Driven Expansion in Grouted Waste-forms - 16125

One of the current preferred solutions for the disposal of Intermediate Level radioactive waste in the UK is grout encapsulation inside steel boxes for long term storage. These boxes are then to be entombed in a Geological Disposal Facility once one is available. However, both prior to and during geological disposal, waste contents can react with the water present in the encapsulant grout and begin to corrode. This corrosion product occupies a larger volume (by several hundred percent) than the original material and the corrosion occurs over the course of decades and centuries, long after the encapsulant grout has set and hardened. The expanding waste then creates stresses in the encapsulant causing both it and the surrounding box to deform and, in extreme circumstances, and after long times, for the structural integrity of the box to fail. This behaviour needs to be quantified before the box can be approved for use as any excessive deformation could lead to a loss of containment or, since the boxes are stacked on top of each other, to a significant accident in the stores. Due to the long timescales involved, physical testing of the phenomenon in full scale is impossible. Instead, a combination of chemical modelling and finite element analysis is used to predict the extent of the corrosion in the waste and its effect of the integrity of the box. There are a number of difficulties in modelling the corrosion-driven expansion and subsequent deformation of the boxes. Although the corrosion occurs over a very long time scale, the event is highly non-linear and dynamic. All of the material models, including the steel and grout are non-linear. The deformation is in the order of 10s of centimetres, well beyond the static elastic range. Finally, the components must be allowed to move relative to each other which involve a lot of part to part contacts. This means that simple static modelling, which would solve quite quickly, cannot be used. Instead a dynamic analysis code, LS-DYNA, has been used to expand the product over time to simulate the corrosion-driven expansion. This software is generally used for modelling car crashes or scenarios where waste containers have been dropped. The analyses therefore include a significant inertial component. This paper will detail the NNL's approach to modelling this long-term, quasi-static phenomenon in the dynamic, impact oriented software code LS-DYNA. It will cover the problems inherent in this approach, the errors that it creates as well as the tests and solutions that NNL worked on in order to overcome them and be confident that the solution could be validated. This work will ultimately be used to determine the maximum inventory which can be stored in each box based on the waste content and the potential extent of expansion as well as any modification that could be made to the box design or the processing streams that may improve the storage solution. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Three-dimensional flow model development for thermal mixing and stratification modeling in reactor system transients analyses

Mixing, thermal-stratification, and mass transport phenomena in large pools or enclosures play major roles for the safety of reactor systems. Depending on the fidelity requirement and computational resources, various modeling methods, from the 0-D perfect mixing model to 3-D Computational Fluid Dynamics (CFD) models, are available. Each is associated with its own advantages and shortcomings. It is very desirable to develop an advanced and efficient thermal mixing and stratification modeling capability embedded in a modern system analysis code to improve the accuracy of reactor safety analyses and to reduce modeling uncertainties. An advanced system analysis tool, SAM, is being developed at Argonne National Laboratory for advanced non-LWR reactor safety analysis. While SAM is being developed as a system-level modeling and simulation tool, a reduced-order three-dimensional module is under development to model the mull-dimensional flow and thermal mixing and stratification in large enclosures of reactor systems. This paper provides an overview of the three-dimensional finite element flow model in SAM, including the governing equations, stabilization scheme, and solution methods. Additionally, several verification and validation tests are presented, including lid-driven cavity flow, natural convection inside a cavity, laminar flow in a channel of parallel plates. Here, based on the comparisons with the analytical solutions and experimental results, it is demonstrated that the developed 3-D fluid model can perform very well for a wide range of flow problems.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Fish-Friendly Hydropower Turbine Development & Deployment: Alden Turbine Preliminary Engineering and Model Testing

The Alden turbine was developed through the U.S. Department of Energy's (DOE's) former Advanced Hydro Turbine Systems Program (1994-2006) and, more recently, through the Electric Power Research Institute (EPRI) and the DOE's Wind & Water Power Program. The primary goal of the engineering study described here was to provide a commercially competitive turbine design that would yield fish passage survival rates comparable to or better than the survival rates of bypassing or spilling flow. Although the turbine design was performed for site conditions corresponding to 92 ft (28 m) net head and a discharge of 1500 cfs (42.5 cms), the design can be modified for additional sites with differing operating conditions. During the turbine development, design modifications were identified for the spiral case, distributor (stay vanes and wicket gates), runner, and draft tube to improve turbine performance while maintaining features for high fish passage survival. Computational results for pressure change rates and shear within the runner passage were similar in the original and final turbine geometries, while predicted minimum pressures were higher for the final turbine. The final turbine geometry and resulting flow environments are expected to further enhance the fish passage characteristics of the turbine. Computational results for the final design were shown to improve turbine efficiencies by over 6% at the selected operating condition when compared to the original concept. Prior to the release of the hydraulic components for model fabrication, finite element analysis calculations were conducted for the stay vanes, wicket gates, and runner to verify that structural design criteria for stress and deflections were met. A physical model of the turbine was manufactured and tested with data collected for power and efficiency, cavitation limits, runaway speed, axial and radial thrust, pressure pulsations, and wicket gate torque. All parameters were observed to fall within ranges expected for conventional radial flow machines. Based on these measurements, the expected efficiency peak for prototype application is 93.64%. These data were used in the final sizing of the supporting mechanical and balance of plant equipment. The preliminary equipment cost for the design specification is $1450/kW with a total supply schedule of 28 months. This equipment supply includes turbine, generator, unit controls, limited balance of plant equipment, field installation, and commissioning. Based on the selected head and flow design conditions, fish passage survival through the final turbine is estimated to be approximately 98% for 7.9-inch (200-mm) fish, and the predicted survival reaches 100% for fish 3.9 inches (100 mm) and less in length. Note that fish up to 7.9- inches (200 mm) in length make up more than 90% of fish entrained at hydro projects in the United States. Completion of these efforts provides a mechanical and electrical design that can be readily adapted to site-specific conditions with additional engineering development comparable to costs associated with conventional turbine designs.

13 HYDRO ENERGY↗

Development of a Reduced-Order Three-Dimensional Flow Model for Thermal Mixing and Stratification Simulation during Reactor Transients

Mixing, thermal-stratification, and mass transport phenomena in large pools or enclosures play major roles for the safety of reactor systems. Depending on the fidelity requirement and computational resources, various modeling methods, from the 0-D perfect mixing model to 3-D Computational Fluid Dynamics (CFD) models, are available. Each is associated with its own advantages and shortcomings. It is very desirable to develop an advanced and efficient thermal mixing and stratification modeling capability embedded in a modern system analysis code to improve the accuracy of reactor safety analyses and to reduce modeling uncertainties. An advanced system analysis tool, SAM, is being developed at Argonne National Laboratory for advanced non-LWR reactor safety analysis. While SAM is being developed as a system-level modeling and simulation tool, a reduced-order three-dimensional module is under development to model the multi-dimensional flow and thermal mixing and stratification in large enclosures of reactor systems. This paper provides an overview of the three-dimensional finite element flow model in SAM, including the governing equations, stabilization scheme, and solution methods. Additionally, several verification and validation tests are presented, including lid-driven cavity flow, natural convection inside a cavity, laminar flow in a channel of parallel plates. Based on the comparisons with the analytical solutions and experimental results, it is demonstrated that the developed 3-D fluid model can perform very well for a wide range of flow problems.

Hu, Rui↗

Optothermal transport behavior in whispering gallery mode optical cavities

Over the past century, whispering gallery mode optical cavities have enabled numerous advances in science and engineering, such as discoveries in quantum mechanics and non-linear optics, as well as the development of optical gyroscopes and add drop filters. One reason for their widespread appeal is their ability to confine light for long periods of time, resulting in high circulating intensities. However, when sufficiently large amounts of optical power are coupled into these cavities, they begin to experience optothermal or photothermal behavior, in which the optical energy is converted into heat. Above the optothermal threshold, the resonance behavior is no longer solely defined by electromagnetics. Previous work has primarily focused on the role of the optothermal coefficient of the material in this instability. However, the physics of this optothermal behavior is significantly more complex. In the present work, we develop a predictive theory based on a generalizable analytical expression in combination with a geometry-specific COMSOL Multiphysics finite element method model. The simulation couples the optical and thermal physics components, accounting for geometry variations as well as the temporal and spatial profile of the optical field. To experimentally verify our theoretical model, the optothermal thresholds of a series of silica toroidal resonant cavities are characterized at different wavelengths (visible through near-infrared) and using different device geometries. The silica toroid offers a particularly rigorous case study for the developed optothermal model because of its complex geometrical structure which provides multiple thermal transport paths.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sensitivity analysis of thermal contact conductance modeling to inform MiniFuel irradiation capsule designs

The MiniFuel irradiation platform has been developed by Oak Ridge National Laboratory as a flexible, high-throughput separate effects testing capability within the High Flux Isotope Reactor (HFIR). Finite element thermal models are relied upon to design MiniFuel experiments to achieve a specific time-averaged irradiation temperature for experimental objectives. A previous study identified that uncertainty in the component heat generation rates and thermal contact conductance (TCC) model are the most significant contributors to predicted fuel temperature variance. To address both sources of uncertainty, this work performs sensitivity analysis on the TCC model to identify high-impact, high-uncertainty parameters that contribute to fuel temperature variance. The TCC model is analyzed in increasing detail, first using a standalone Python code, then again after coupling Python to the BISON fuel performance code. Furthermore, the parameters with the largest contributions to fuel temperature variance which can be reduced through design changes are identified as the initial subcapsule gas pressure, contact pressure between the fuel and dish, and the effective surface roughness of the interface. A set of design recommendations for future capsule designs has been established and applied to reduce the previously quantified average fuel temperature uncertainty ranges of ± 40 °C in the HFIR vertical experiment facilities (VXF) and ± 80 °C in the removable beryllium (RB) reflector to approximately ± 32 °C and ± 53 °C, respectively. This equates to a 21 % and 33 % reduction in the uncertainty range of the average fuel temperature for VXF and RB, respectively.

BISON↗

Assessing the Validity of the Simplified Potential Energy Clock Model for Modeling Glass-Ceramics

Glass-ceramic seals may be the future of hermetic connectors at Sandia National Laboratories. They have been shown capable of surviving higher temperatures and pressures than amorphous glass seals. More advanced finite-element material models are required to enable model-based design and provide evidence that the hermetic connectors can meet design requirements. Glass-ceramics are composite materials with both crystalline and amorphous phases. The latter gives rise to (non-linearly) viscoelastic behavior. Given their complex microstructures, glass-ceramics may be thermorheologically complex, a behavior outside the scope of currently implemented constitutive models at Sandia. However, it was desired to assess if the Simplified Potential Energy Clock (SPEC) model is capable of capturing the material response. Available data for SL 16.8 glass-ceramic was used to calibrate the SPEC model. Model accuracy was assessed by comparing model predictions with shear moduli temperature dependence and high temperature 3-point bend creep data. It is shown that the model can predict the temperature dependence of the shear moduli and 3- point bend creep data. Analysis of the results is presented. Suggestions for future experiments and model development are presented. Though further calibration is likely necessary, SPEC has been shown capable of modeling glass-ceramic behavior in the glass transition region but requires further analysis below the transition region.

36 MATERIALS SCIENCE↗

Cohesive Zone Modeling in Geomaterial

The purpose of the two projects discussed in this report is to use the cohesive zone method to evaluate fracture properties of geomaterials. Two experimental tests, the push-out test and the notched three-point bend test, were modeled computationally using finite element analysis and cohesive zone modeling to extract load and displacement information and ultimately determine failure behavior. These results are to be compared with experimental tests when they are available. The first project used the push-out test to investigate the shear bond strength at the cement- shale interface. The second project explored the effects of scaling a notched three-point bending specimen to study fracture toughness characteristics. The bond strength and fracture toughness of a material and its interfaces are important parameters to consider in subsurface applications so that zonal isolation can be achieved.

42 ENGINEERING↗

Identification Uncertainty in Inverse Material Model Parameter Determination: A Sensitivity‐Based Decision Process for Load Path Selection

This research proposes a sensitivity-based framework for selecting the optimal prescribed loading path for a biaxial cruciform specimen. Optimality here is determined by the direction and magnitude of the prescribed displacement that minimizes the influence of random noise on the material model parameter identification. Using simulated experimental data based on finite element simulation, in this work, we identify the material model parameters of a Ludwik hardening model and plane stress implementation of the Hill-48 yield criterion using finite element model updating (FEMU). Our analysis reveals that the identification (or estimator) uncertainty of model parameters depends on the displacement boundary conditions (i.e., loading sequence) and the ground-truth value of the individual parameters. Optimal experimental design (OED) criteria based on the Fisher information matrix were investigated to mitigate indecision in the choice of optimal load path when the identification uncertainty of different material model parameters optimized at different load paths. The determinant of the Fisher information matrix was chosen here as the more useful metric due to its ability to capture uncertainty of the most influential material model parameters. The proposed framework demonstrates potential for real-time automated load step selection using scalar criteria derived prior to mechanical loading. The framework can be generalized to other geometries, boundary conditions and material models, allowing this procedure to be utilized for different experimental configurations and materials.

Fayad, Samuel S. [University of Illinois at Urbana↗

AGR-5/6/7 CAPSULE 1 THERMAL MODEL WITH OFFSET GAS GAPS

Fuel compact temperatures are a crucial factor in assessing the irradiation performance of tristructural isotropic (TRISO) fuel particles. In the absence of direct measurement, fuel compact temperatures were calculated using a 3 D finite-element thermal model that was subject to simulation uncertainty. The most dominant factor in the uncertainty of calculated fuel temperatures is the gas gap uncertainty caused by the graphite holder nub-to-capsule clearance. This thermal model was revised to examine the most probable graphite offset position for Capsule 1 for four different days during the irradiation. In the analysis, the offset distance and azimuthal direction at both the top and bottom of the holder were varied. The best-fit offset was estimated based on the minimum root mean square error (RMSE) of the residuals (measured minus calculated thermocouple [TC] temperatures) for the operational TCs in Capsule 1. Near the end of the irradiation, when the graphite had shrunk and the gas gaps had grown, a peak temperature was found with maximum offset along the TC lines, with nickel introducing a potential mechanism for fuel particle failures.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

GPHS Module Pre-Impact test Temperature Prediction with ANSYS [PowerPoint]

The purpose of the project was to: Develop a finite element thermal model of the General Purpose Heat Source (GPHS) Module loaded with four fueled clads; Perform steady state analysis to validate the thermal model via energy balance; Perform transient thermal analysis to predict clad temperatures at various times; and, Transient model results will be used to inform module soak time needed to reach a desired clad temperature prior to impact.

42 ENGINEERING↗

AGR-5/6/7 Thermal Model with Non-uniform Gas Gaps

Fuel compact temperatures are a crucial factor in assessing irradiation performance of the Tristructural isotropic fuel particles. In the absence of direct measurement, fuel compact temperatures were calculated using a three-dimensional finite element thermal model, which is subject to simulation uncertainty. The most dominant factor in uncertainty of calculated fuel temperature is the gas gap uncertainty due to the nub-to-shell clearance because of fabrication error. A revision to the thermal model was made to examine the most probable offset position for four different dates of interest. The offset position options varied in magnitude and azimuthal direction of offset of the holder top and bottom position. The best-fit offset of the holder is estimated based on the minimum root mean square error of residuals for all operational thermocouples (TCs). From these results, the following conclusions were made: 1) During earlier cycles (162A – 164A) when numerous TCs were still operational, the best-fit offset distance varied in range [0.002 – 0.0035 in.] for both the top and bottom holder while offset azimuthal direction varied widely, especially for the holder bottom. 2) Holder offset led to slightly lower Capsule 1 average temperature, but wider temperature variation (lower minimum and higher peak fuel temperatures). 3) The maximum offset of 0.006 in. to the northwest direction for both the top and bottom holder yielded a much higher temperature than the original peak fuel temperature, which increased from 1422 to 1557 ? (or 135 ? increase). This could be one of the reasons for massive particle failure near the end of Cycle 165A. 4) Even though, the highest temperature at the TC-1-7 tip reached slightly higher than 1000?, the temperature along the TC wire reached as high as 1335? assuming a holder offset of 0.006 in. to the northwest. Consequently, at this temperature nickel from this TC wire could cause particle failures in Capsule 1.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Simulation of the ultrasonic array response from real branched cracks using an efficient finite element method

A hybrid model to simulate the ultrasonic array response from stress corrosion cracks is presented. These cracks are branched and difficult to detect so the model is required to enable optimization of an array design. An efficient frequency-domain finite element method is described and selected to simulate the ultrasonic scattering. Experimental validation results are presented, followed by an example of the simulated ultrasonic array response from a real stress corrosion crack whose geometry is obtained from an X-ray Computed Tomography image. A simulation-assisted array design methodology, which includes the model and use of real crack geometries, is proposed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗