Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FERROMAGNETISM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Ferromagnetic tunnel contacts to graphene: Contact resistance and spin signal

We report spin transport in CVD graphene-based lateral spin valves using different magnetic contacts. We compared the spin signal amplitude measured on devices where the cobalt layer is directly in contact with the graphene to the one obtained using tunnel contacts. Although a sizeable spin signal (up to ∼2 Ω) is obtained with direct contacts, the signal is strongly enhanced (∼400 Ω) by inserting a tunnel barrier. In addition, we studied the resistance-area product (R.A) of a variety of contacts on CVD graphene. In particular, we compared the R.A products of alumina and magnesium oxide tunnel barriers grown by sputtering deposition of aluminum or magnesium and subsequent natural oxidation under pure oxygen atmosphere or by plasma. When using an alumina tunnel barrier on CVD graphene, the R.A product is high and exhibits a large dispersion. This dispersion can be highly reduced by using a magnesium oxide tunnel barrier, as for the R.A value. This study gives insight in the material quest for reproducible and efficient spin injection in CVD graphene.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Determination of the Schottky barrier height of ferromagnetic contacts to few-layer phosphorene

Phosphorene, the 2D analogue of black phosphorus, is a promising material for studying spin transport due to its low spin-orbit coupling and its ½ nuclear spin, which could allow the study of hyperfine effects. In this work, the properties of permalloy (Py) and cobalt (Co) contacts to few-layer phosphorene are presented. The Schottky barrier height was extracted and determined as a function of gate bias. Flat-band barrier heights, relative to the valence band edge, of 110 meV and 200 meV were determined for Py and Co, respectively. These results are important for future studies of spin transport in phosphorene.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Phase transitions in continuum ferromagnets with unbounded spins

States of thermal equilibrium of an infinite system of interacting particles in ℝ{sup d} are studied. The particles bear “unbounded” spins with a given symmetric a priori distribution. The interaction between the particles is pairwise and splits into position-position and spin-spin parts. The position-position part is described by a superstable potential, and the spin-spin part is attractive and of finite range. Thermodynamic states of the system are defined as tempered Gibbs measures on the space of marked configurations. It is proved that the set of such measures contains at least two elements if the activity is big enough.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental determination of next-nearest-neighbor interlayer exchange coupling in ferromagnetic GaMnAs/GaAs:Be multilayers

We report direct experimental determination of next-nearest-neighbor (NNN) interlayer exchange coupling (IEC) in antiferromagnetically coupled GaMnAs/GaAs:Be multilayers. Magnetoresistance in such multilayers shows step-like transitions as a function of applied magnetic field that corresponds to abrupt changes of spin configuration. By adjusting the field range, one obtains minor hysteresis loops that allow one to determine spin configurations occurring in the multilayer, which in turn can be used to obtain the ratio of NNN IEC to NN IEC. By using this method on a series of GaMnAs/GaAs:Be with different numbers of GaMnAs layers, we obtain this ratio to be 0.23, in good agreement with theoretical predictions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Magnetic microstructure and magnetic properties of uniaxial itinerant ferromagnet Fe 3 GeTe 2

Here, magnetic force microscopy was used to observe the magnetic microstructure of Fe 3 GeTe 2 at 4 K on the (001) surface. The surface magnetic structure consists of a two-phase domain branching pattern that is characteristic for highly uniaxial magnets in the plane perpendicular to the magnetic easy axis. The average surface magnetic domain width D s = 1.3 μm determined from this pattern, in combination with intrinsic properties calculated from bulk magnetization data (the saturation magnetization M s = 376 emu/cm 3 and the uniaxial magnetocrystalline anisotropy constant K u = 1.46 × 10 7 erg/cm 3 ), was used to determine the following micromagnetic parameters for Fe 3 GeTe 2 from phenomenological models: the domain wall energy γ w = 4.7 erg/cm 2 , the domain wall thickness δ w = 2.5 nm, the exchange stiffness constant A ex = 0.95 × 10 –7 erg/cm, the exchange length l ex = 2.3 nm, and the critical single domain particle diameter d c = 470 nm.

36 MATERIALS SCIENCE↗

Robust giant anomalous Nernst effect in polycrystalline nodal web ferromagnets

The transverse thermoelectric effect based on the anomalous Nernst effect (ANE) has attracted attention, especially for thermoelectric and spintronic applications. Fe3X (X = Ga, Al) is known to exhibit a large ANE at room temperature owing to the topological electronic band structure so-called nodal web. Here, we systematically investigate ANE in the polycrystalline Fe3Ga1−xAlx and Fe3Al1−xSix. Despite significant chemical substitutions, a very robust feature of the large ANE −Syx∼ 5.7 μ V/K is found for Fe3Ga1−xAlx (0≲x≲0.6), exhibiting a striking x independent nodal web contribution. Since aluminum is more low-cost and abundant than gallium, our results indicate Fe3Ga1−xAlx (x∼0.6) should be suitable for large-scale thermoelectric applications.

Physics↗

Element- and Time-Resolved Measurements of Spin Dynamics Using X-ray Detected Ferromagnetic Resonance

Although XFMR experiments have been carried out at a number of synchrotron radiation facilities since 2004, only a few facilities currently have XFMR setups available for user operation. Here in this review, we mainly focus on recent developments and work that has been carried out using time-resolved XFMR at beamline 4.0.2 of the Advanced Light Source and at beamline I10 of the Diamond Light Source. The experimental setup and the sample holder used at beamline I10 and beamline 4.0.2, respectively, are shown in Figure 1. We will first introduce the working principle of XFMR and then provide examples of the capabilities of this technique. Finally, we will briefly describe an outlook for the future development of and new opportunities for XFMR.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗