Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Extraction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Broad, intense, quiescent beam of singly charged metal ions obtained by extraction from self-sputtering plasma far above the runaway threshold

Dense metal plasmas obtained by self-sputtering far above the runway threshold are well suited to generate intense quiescent ion beams. The dilemma of high current density and charge state purity can be solved when using target materials of low surface binding energy by utilizing non-resonant exchange reactions before ion extraction. Space-charge-limited quiescent beams of Cu+, Zn+, and Bi+ with ~;;10 mA/cm2 have been obtained through multi-aperture gridded ion extraction up to 45 kV from self-sputtering plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma potential and energy spread determination using ion beams extracted from an electron cyclotron resonance source

We have obtained estimates of plasma potentials and energy spreads characterizing an electron cyclotron resonance ion source plasma under different source conditions. Our estimates are obtained from analysis of ion beams extracted from the ion source at 10 kV that are subsequently decelerated into a floating surface scattering chamber where their current intensity incident on a solid sample is measured as function of retardation voltage. The deceleration occurs outside the measurement chamber, permitting beam current measurements in a field-free region. Absence of grids in the deceleration section avoids potential issues of field penetration. The behavior of our deceleration optics was modeled with SIMION. The simulation indicated a linear beam attenuation dependence close to full retardation where the beam current goes to zero. Deviations from this linear dependence observed close to zero beam energy give information on the initial energy spread of the ions extracted from the source. Our decelerated beams measurements are compared with recent in situ probe results and external beams results based on magnetic analysis.

43 PARTICLE ACCELERATORS↗

Plasma Sputter-type Ion Source with Wire Electrodes for Low-energy Gallium Ion Extraction

Low-energy ions of gallium (Ga) and argon (Ar) were extracted from a plasma sputter-type ion source system that utilized a tungsten (W) wire extractor geometry. The 90% transparent W wire extractor configuration had shown that the system was capable of producing an ion beam with the energy as low as 10 eV in a dc filament discharge and 50 eV in a radio frequency (rf) excited system. In the present investigation, Ar plasma was sustained in an ion source chamber through an inductively coupled 13.56 MHz rf power source. Negatively biased liquid Ga target suspended on a W reservoir was sputtered and postionized prior to extraction. Mass spectral analyses revealed a strong dependence of the Ga{sup +} current on the induced target bias.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Light Cone Dynamics and EMC Effects in the Extraction of F{sub 2n} at Large Bjorken x

We discuss theoretical issues related to the extraction of deep inelastic (DIS) structure function of neutron from inclusive DIS scattering off the deuteron at large Bjorken x. Theoretical justification is given to the consideration of only pn component of the deuteron wave function and consistency with both the baryonic number and light-cone momentum conservation sum rules. Next we discuss the EMC type effects and argue that in all cases relevant to the nuclear DIS reactions at large x the main issue is the medium modification of the properties of bound nucleon rather than the non-nucleonic components like pions. We give brief description of the color screening model of EMC and within this model we estimate uncertainties in the extraction of the neutron DIS structure function at large x. We emphasize also that these uncertainties are rather ''model independent'' since any theoretical framework accounting for the medium modification is proportional to the magnitude of the virtuality of bound nucleon which increases with an increase of x.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Electron current extraction from a permanent magnet waveguide plasma cathode

An electron cyclotron resonance plasma produced in a cylindrical waveguide with external permanent magnets was investigated as a possible plasma cathode electron source. The configuration is desirable in that it eliminates the need for a physical antenna inserted into the plasma, the erosion of which limits operating lifetime. Plasma bulk density was found to be overdense in the source. Extraction currents over 4 A were achieved with the device. Measurements of extracted electron currents were similar to calculated currents, which were estimated using Langmuir probe measurements at the plasma cathode orifice and along the length of the external plume. The influence of facility effects and trace ionization in the anode-cathode gap are also discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Extraction of $P_{11}$ Resonance from piN Data and Its Stability

We address a question about how much resonance poles and residues extracted from data depend on a model used for the extraction, and on the precision of data. We focus on the P{sub 11} {pi}-N scattering and use the dynamical coupled-channel (DCC) model developed in Excited Baryon Analysis Center (EBAC) at JLab. We examine the model-dependence of the poles by varying parameters largely within the EBAC-DCC model. We find that two poles associated with the Roper resonance are fairly stable against the variation. We also study the stability of the Roper poles against different analytic structure of the P{sub 11} amplitude below {pi}-N threshold by using a bare nucleon model. We again find a good stability of the Roper poles.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Uncertainties in model-independent extractions of amplitudes from complete experiments

A new generation of over-complete experiments is underway, with the goal of performing a high precision extraction of pseudoscalar meson photo-production amplitudes. Such experimentally determined amplitudes can be used both as a test to validate models and as a starting point for an analytic continuation in the complex plane to search for poles. Of crucial importance for both is the level of uncertainty in the extracted multipoles. We have probed these uncertainties by analyses of pseudo-data for KLambda photoproduction, first for the set of 8 observables that have been published for the K{sup +} Lambda channel and then for pseudo-data on a complete set of 16 observables with the uncertainties expected from analyses of ongoing CLAS experiments. In fitting multipoles, we have used a combined Monte Carlo sampling of the amplitude space, with gradient minimization, and have found a shallow X{sup 2} valley pitted with a large number of local minima. This results in bands of solutions that are experimentally indistinguishable. All ongoing experiments will measure observables with limited statistics. We have found a dependence on the particular random choice of values of Gaussian distributed pseudo-data, due to the presence of multiple local minima. This results in actual uncertainties for reconstructed multipoles that are often considerable larger than those returned by gradient minimization routines such as Minuit which find a single local minimum. As intuitively expected, this additional level of uncertainty decreases as larger numbers of observables are included.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Disorganization of cell division of methicillin-resistant Staphylococcus aureus by methanolic extract from Phyllanthus columnaris stem bark

The in vitro activity of methanolic extract from Phyllanthus columnaris stem bark was studied against Methicillin-resistant Staphylococcus aureus (MRSA) ATCC 43300 and MRSA BM1 (clinical strain) using time-kill curves in conjunction with scanning and transmission electron microscopy. The extract showed more markedly bactericidal activity in MRSA BM1 clinical strain within less than 4 h by 6.25-12.5 mg/mL and within 6 h by 1.56 mg/mL. Scanning electron microscopy of MRSA BM1 revealed distortion of cell whilst transmission electron microscopy revealed disruption in cell wall division.

60 APPLIED LIFE SCIENCES↗

Sodium bromide electron-extraction layers for polymer bulk-heterojunction solar cells

Inexpensive and non-toxic sodium bromide (NaBr) was introduced into polymer solar cells (PSCs) as the cathode buffer layer (CBL) and the electron extraction characteristics of the NaBr CBL were investigated in detail. The PSCs based on NaBr CBL with different thicknesses (i.e., 0 nm, 0.5 nm, 1 nm, and 1.5 nm) were prepared and studied. The optimal thickness of NaBr was 1 nm according to the photovoltaic data of PSCs. The open-circuit voltage (V{sub oc}), short-circuit current density (J{sub sc}), fill factor (FF), and power conversion efficiency (PCE) of the PSC with 1 nm NaBr were evaluated to be 0.58 V, 7.36 mA/cm{sup 2}, 0.63, and 2.70%, respectively, which were comparable to those of the reference device with the commonly used LiF. The optimized photovoltaic performance of PSC with 1 nm NaBr was ascribed to the improved electron transport and extraction capability of 1 nm NaBr in PSCs. In addition, the NaBr CBL could prevent the diffusion of oxygen and water vapor into the active layer and prolong the lifetime of the devices to some extent. Therefore, NaBr layer could be considered as a promising non-toxic CBL for PSCs in future.

36 MATERIALS SCIENCE↗

A simple scheme for injection and extraction in compact rings

There has been great interest in building compact synchrotrons for various applications, for example, inverse Compton scattering X-ray sources. However, the beam injection and extraction in compact rings require careful design for the lack of space. In this paper, we propose a simple combined injection-extraction scheme exploiting the fringe field of existing dipole magnets instead of additional septum magnets. This scheme is illustrated by using the 4.8 m ring proposed for Tsinghua Thomson scattering X-ray source as an example. Particle tracking is applied to demonstrate the validity of this scheme.

43 PARTICLE ACCELERATORS↗

Experimental optimization of beam quality extracted from a duoplasmatron proton ion source

The LANSCE accelerator facility operates with two independent ion injectors for H⁺ and H⁻ particle beams. The H⁺ ion beam is formed using a duoplasmatron source followed by a 750 keV Cockroft-Walton accelerating column. Formation of an optimal plasma meniscus is an important feature for minimizing beam emittance, and maximizing beam brightness. A series of experiments were performed to find the optimal combination of extraction voltage and extracted current for the H⁺ beam. Measurements yielded the best ratio of beam perveance to Child–Langmuir perveance of 0.52 for maximizing beam brightness.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of disorder on spin injection and extraction for organic semiconductor spin-valves

A device model for tunnel injection and extraction of spin-polarized charge carriers between ferromagnetic contacts and organic semiconductors with disordered molecular states is presented. Transition rates for tunneling are calculated based on a transfer Hamiltonian. Transport in the bulk semiconductor is described by macroscopic device equations. Tunneling predominantly involves organic molecular levels near the metal Fermi energy, and therefore typically in the tail of the band that supports carrier transport in the semiconductor. Disorder-induced broadening of the relevant band plays a critical role for the injection and extraction of charge carriers and for the resulting magneto-resistance of an organic semiconductor spin valve.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Green synthesis of gold nanoparticles using aqueous ethanol extract of Curcuma mangga rhizomes as reducing agent

Green synthesis of gold nanoparticles (AuNPs) had been developed as an alternative to chemical and physical methods due to its simplicity, cost effectiveness and eco-friendliness. The high biocompatibility and biostability features of AuNPs have found importance in biomedical applications in recent years. In this study, aqueous ethanol extract of Curcuma mangga rhizomes which acts as reducing and stabilizing agent was used to synthesize stable AuNPs by bioreduction of chloroauric acid. The formation of AuNPs was highlighted by the color change of the suspension from light yellow to reddish purple. Time-evolution was monitored by UV-visible spectroscopy, while surface plasmon (SP) absorption band of the AuNPs suspension was observed at a maximum absorption of 540 nm. Hydrodynamic radii and size distribution of the AuNPs in the suspension were evaluated using dynamic light scattering (DLS) and zeta potential measurement demonstrated negative surface charge. The particle size was calculated in the range of 2-30 nm using High Resolution Transmission Electron Microscopy (HRTEM). The morphology and elemental composition were further determined by Field Effect Scanning Electron Microscopy (FESEM) and Energy Dispersive X-ray (EDX) spectroscopy. Fourier transform infrared (FTIR) spectroscopy meanwhile was used to confirm the presence of AuNPs and functional groups involved in the gold bio-reduction process. Influence of the volume of extract and concentration of gold (III) chloride trihydrate (HAuCl{sub 4}.3H{sub 2}O) on the synthesis of AuNPs were also investigated. The results obtained indicate potential optimization and functionalization of AuNPs for future applications in bionanotechnology especially in the field of medicine.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Band alignment and photon extraction studies of Na-doped MgZnO/Ga-doped ZnO heterojunction for light-emitter applications

Ultraviolet photoelectron spectroscopy is carried out to measure the energy discontinuity at the interface of p-type Na-doped MgZnO (NMZO)/n-type Ga-doped ZnO (GZO) heterojunction grown by dual ion beam sputtering. The offset values at valence band and conduction band of NMZO/GZO heterojunction are calculated to be 1.93 and −2.36 eV, respectively. The p-type conduction in NMZO film has been confirmed by Hall measurement and band structure. Moreover, the effect of Ar{sup +} ion sputtering on the valence band onset values of NMZO and GZO thin films has been investigated. This asymmetric waveguide structure formed by the lower refractive index of GZO than that of NMZO indicates that easy extraction of photons generated in GZO through the NMZO layer into free space. The asymmetric waveguide structure has potential applications to produce ZnO-based light emitters with high extraction efficiency.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Detailed beam and plasma measurements on the vessel for extraction and source plasma analyses (VESPA) Penning H{sup −} ion source

A vessel for extraction and source plasma analyses (VESPA) is operational at the Rutherford Appleton Laboratory (RAL). This project supports and guides the overall ion source R&D effort for the ISIS spallation neutron and muon facility at RAL. The VESPA produces 100 mA of pulsed H{sup −} beam, but perveance scans indicate that the source is production-limited at extraction voltages above 12 kV unless the arc current is increased. A high resolution optical monochromator is used to measure plasma properties using argon as a diagnostic gas. The atomic hydrogen temperature increases linearly with arc current, up to 2.8 eV for 50 A; whereas the electron temperature has a slight linear decrease toward 2.2 eV. The gas density is 10{sup 21} m{sup −3}, whilst the electron density is two orders of magnitude lower. Densities follow square root relationships with arc current, with gas density decreasing whilst electron (and hence ion) density increases. Stopping and range of ions in matter calculations prove that operating a high current arc with an argon admixture is extremely difficult because cathode-coated cesium is heavily sputtered by argon.

43 PARTICLE ACCELERATORS↗

Simulation of ion beam injection and extraction in an EBIS

An example simulation of Au+ charge breeding using FAR-TECH’s integrated EBIS (electron beam ion source) modeling toolset is presented with the emphasis on ion beam injection and extraction. The trajectories of injected ions are calculated with PBGUNS (particle beam gun simulation) self-consistently by including the space charges from both ions and electrons. The ion beam, starting with initial conditions within the 100% acceptance of the electron beam, is then tracked by EBIS-PIC (particle-in-cell EBIS simulation code). In the trap, the evolution of the ion charge state distribution is estimated by charge state estimator. The extraction of charge bred ions is simulated with PBGUNS. The simulations of the ion injections show significant ion space charge effects on beam capture efficiency and the ionization efficiency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Oscillatory instability development in extraction system of a negative ion source

Conditions of oscillatory instability development in the extraction system of a negative hydrogen ion source based on a volume-produced plasma are studied. Such an ion source is characterized by the presence of the parent gas in the extraction system due to the leakage from the gas-discharge chamber. The secondary electrons in the area of the ion-optical system become the reason of oscillation appearance and possible beam current modulation. Analytically the range of the stable beam propagation is found. The instability increment is shown to be rather small. Maximum increment of the oscillations corresponds to the beam velocity equal to the thermal velocity of plasma electrons. The group velocity of the oscillations is close to the beam velocity so the oscillations are convective. Simulation of the low energy beam propagation is performed in COMSOL Multiphysics, the beam current modulation being observed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Shell stability and conditions analyzed using a new method of extracting shell areal density maps from spectrally resolved images of direct-drive inertial confinement fusion implosions

In warm target direct-drive ICF implosion experiments performed at the OMEGA laser facility, plastic microballoons doped with a titanium tracer layer in the shell and filled with deuterium gas were imploded using a low-adiabat shaped laser pulse. Continuum radiation emitted in the core is transmitted through the tracer layer and the resulting spectrum recorded with a gated multi-monochromatic x-ray imager (MMI). Titanium K-shell line absorption spectra observed in the data are due to transitions in L-shell titanium ions driven by the backlighting continuum. The MMI data consist of an array of spectrally resolved images of the implosion. These 2-D space-resolved titanium spectral features constrain the plasma conditions and areal density of the titanium doped region of the shell. The MMI data were processed to obtain narrow-band images and space resolved spectra of titanium spectral features. Shell areal density maps, ρL(x,y), extracted using a new method using both narrow-band images and space resolved spectra are confirmed to be consistent within uncertainties. We report plasma conditions in the titanium-doped region of electron temperature (T e ) = 400±28eV, electron number density (N e ) = 8.5x10 24 ±2.5x10 24 cm -3 , and average areal density <ρR> = 86±7mg/cm 2 . Fourier analysis of areal density maps reveals shell modulations caused by hydrodynamic instability growth near the fuel-shell interface in the deceleration phase. We observe significant structure in modes l = 2-9, dominated by l = 2. We extract a target breakup fraction of 7.1±1.5% from our Fourier analysis. A new method for estimating mix width is evaluated against existing literature and our target breakup fraction. We estimate a mix width of 10.5±1μm.

42 ENGINEERING↗