Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Electric Generators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Predicting Electrical Conductivity in Bi-Metal Composites

Generating high magnetic fields requires materials with not only high electric conductivity but also good strength properties in order to withstand the necessarily strong Lorentz forces. A number of bi-metal composites, most notably Cu/Nb, are considered to be good candidates for this purpose. Here, we generalize our previous work on Cu/Nb in order to predict, from theory, the dependence of electric conductivity on the microstructure and volume fraction of the less conductive component for a number of other bi-metal composites. Together with information on strength properties (taken from previous literature), the conductivity information we provide in this work can help to identify new promising candidate materials (such as Cu/Nb, Cu/Ag, Cu/W, …) for magnet applications with the highest achievable field strengths.

36 MATERIALS SCIENCE↗

NPP Simulators for Coupled Thermal and Electric Power Dispatch

The Light Water Reactor Sustainability (LWRS) program within the United States Department of Energy supports extending the operation of the U.S. commercial nuclear power plant (NPP) fleet. Within the LWRS program, the Flexible Plant Operation and Generation (FPOG) Pathway works to diversify the revenue streams of light water reactors (LWRs) by opening opportunities for the co-generation of non-electric products in addition to supplying electrical power to the grid. Recent events have added greater motivation to these efforts. For example, the recent Inflation Reduction Act (IRA) passed by the U.S. federal government offers substantial tax incentives for producing clean hydrogen, the technology readiness level of dispatchable and high-efficiency hydrogen production has dramatically increased in a short time, and societal response to world climate change is driving a transition away from fossil fuels. Producing hydrogen with maximum efficiency using nuclear power requires dispatching both electrical and thermal power from the nuclear plant to the hydrogen plant, so testing concepts of operations for combined electrical and thermal power dispatch (TPD) from an NNP to a hydrogen plant is of interest. This report documents achievement of the Light Water Reactor Sustainability (LWRS) program milestone “Install and demonstrate a vendor-developed simulator on the Human Systems Simulation Laboratory (HSS) for dispatch of LWR electrical power to a close-coupled electrolysis plant” with a due date of Dec. 22, 2022. Several factors provide motivation for this effort. Coupling the power generation deck of a nuclear power plant to a hydrogen production facility introduces new possibilities for operational transients that must be addressed. In particular, the performance of the integrated system during startup and shutdown of the hydrogen production facility, as well as offnormal conditions, need to be evaluated to ensure there are no adverse effects on the operation of the existing NPP. The concept of operations involving the NPP, the hydrogen plant, and the electric power grid must be tested using NPP simulators and operating procedures that have been modified for TPD operations. These tests must also include dynamic simulations of the coupled tertiary thermal and electric loads as well as coordinated activities with NPP operators, tertiary load operators and grid power coordinators. The report summarizes progress in developing and testing full-scope NPP simulators at the HSSL, including a generic BWR simulator from GSE Systems, Inc. and generic PWR simulator from Westinghouse. In the case of the TPD-GBWR Simulator from GSE Systems, Inc., a BWR is thermally coupled to a high temperature electrolysis (HTE) plant that produces hydrogen and oxygen from de-ionized water. The hydrogen plant is not explicitly simulated but only included as a transient heat sink. A thermal power dispatch (TPD) system transfers heat between the steam systems at the BWR and the hydrogen plant. Operational results from two versions of the modified simulator are presented. The first version uses synthetic oil as a heat transfer fluid in a closed delivery heat loop (DHL) that generates steam at the hydrogen plant. The second version uses steam as the heat transfer fluid in a delivery steam line (DSL) to provide steam to the hydrogen plant. For both versions, the estimated thermal power delivery distance is approximately one kilometer. The amount of thermal power dispatched in the simulators is 15% of the total reactor thermal power such that the simulators provide a tool to study the feasibility of coupling a BWR to industrial processes that benefit from a combination electrical and thermal power dispatch. Ongoing work within a CRADA is also developing a full-scope PWR simulator provided by Westinghouse for both thermal and electric power coupling. This simulator is based on a PWR plant with two three-loop Westinghouse reactors. Westinghouse PWRs are sufficiently similar that a simulator of a three-loop reactor is an appropriate representation for two-loop and four-loop PWR reactors. The three-loop simulator will initially be modified for close-coupling to a 100 MW HTE hydrogen production plant that will require approximately 25 MW of thermal power while operating at its maximum rated capacity. The simulator testing will include full coupling to dynamic simulations of a hydrogen production plant and a representative bulk electric grid. The simulator provided by Westinghouse is similar to the GPWR simulator that INL has already obtained from GSE Systems but has a few important added benefits. First, the Westinghouse simulator is based on digital controls and has additional screens that can be called up to show parameter trends to assist operators in decision-making. The Westinghouse simulator also has upgrades to the controls and hardware representations, such as valve actuators, that make it more realistic and flexible in terms of accurately sim

99 GENERAL AND MISCELLANEOUS↗

Cost and Life-Cycle Greenhouse Gas Implications of Integrating Biogas Upgrading and Carbon Capture Technologies in Cellulosic Biorefineries

We discuss gaseous streams in biorefineries that have been undervalued and underutilized. In cellulosic biorefineries, coproduced biogas is assumed to be combusted alongside lignin to generate process heat and electricity. Biogas can instead be upgraded to compressed biomethane and used as a transportation fuel. Capturing CO 2 -rich streams generated in biorefineries can also contribute to greenhouse gas (GHG) mitigation goals. We explore the economic and life-cycle GHG impacts of biogas upgrading and CO 2 capture and storage (CCS) at ionic liquid-based cellulosic ethanol biorefineries using biomass sorghum. Without policy incentives, biorefineries with biogas upgrading systems can achieve a comparable minimum ethanol selling price (MESP) and reduced GHG footprint ($1.38/liter gasoline equivalent (LGE) and 12.9 gCO 2e /MJ) relative to facilities that combust biogas onsite ($1.34/LGE and 24.3 gCO 2e /MJ). Incorporating renewable identification number (RIN) values advantages facilities that upgrade biogas relative to other options (MESP of $0.72/LGE). Incorporating CCS increases the MESP but dramatically decreases the GHG footprint (-21.3 gCO 2e /MJ for partial, -110.7 gCO 2e /MJ for full CCS). The addition of CCS also decreases the cost of carbon mitigation to as low as $52-$78/t CO 2 , depending on the assumed fuel selling price, and is the lowest-cost option if both RIN and California's Low Carbon Fuel Standard credits are incorporated.

09 BIOMASS FUELS↗

Realistic Estimation of CO2 Emission Reductions Due to Building Retrofit

Constant CO2 emission factors of electricity are often used to study the emissions of buildings. However, in the era of increased renewable energy for power generation, emission factors of electricity are dynamically changing. This study is to investigate the impact of dynamic CO2 emission factors, which are more realistic than constant ones, on the emission reductions due to building retrofits. The results reveal that if dynamic CO2 emission factors are used for U.S. medium office buildings, improving the efficiency of lighting or electric equipment will lead to more emission reductions in locations with high wind power penetration (e.g., 12% more reductions in Rochester) and fewer reductions in locations with high solar power penetration (e.g., 8% fewer reductions in San Diego). As for improving envelope insulation, dynamic CO2 emission factors have more impact on the emission reductions in hot climates than in cold climates.

Lou, Yingli↗

Powering Data Centers with Clean Energy: A Techno-Economic Case Study of Nuclear and Renewable Energy Dependability

Rising data demands from artificial intelligence (AI) and large language models (LLMs) generating images, videos, and text have prompted increased need for larger and more robust data centers in the United States. Major companies interested in these larger data centers face the choice of linking them to existing regional grids, building stand-alone power supplies onsite, or a combination of both. The request, review, and approval process for new transmission lines to grids in the United States, however, has grown in recent years to times spans rivaling those of new construction for nuclear power plants. Building an islanded power supply for each data center is therefore becoming a prominent option. In this case study, several technologies are modeled in techno-economic simulations for long-term system costs subject to fixed electricity demand from a singular data center. A 250 MWe data center is assumed with additional 50 MWe for resiliency. Techno-economic simulations are conducted using the Holistic Energy Resource Optimization Network (HERON) software, which is a part of the Framework for Optimization of Resources and Economics (FORCE) tool suite. Technologies considered include solar, wind, lithium-ion batteries, and several types of nuclear reactors: large-scale reactors, small modular reactors, and microreactors. A low- and high-cost estimate for each technology is assumed to develop a range of expected economic performance. Low-cost estimates included several clean energy production tax credits. Different combinations of renewable energy generators with nuclear reactors are considered, ranging from a fully renewable-powered data center to a fully nuclear-powered data center. Historic time series of wind and solar availability from the Texas grid are used to train a reduced order model; this model then generates unique time series with similar characteristics of the training dataset. Multiple scenarios of weather and subsequent operations are simulated for each renewable-nuclear combination to determine total costs throughout the project lifetime. Fully renewable-powered configurations required large amounts of installed capacity (GW scale) in the simulations to meet the fixed demand of the data center. This is due to some scenarios in the historical dataset which captured low-wind and low-solar days, requiring over-building of these technologies as well as batteries to compensate for the low amounts of electricity generation. Fully nuclear-powered configurations outperformed the fully renewable and mixed renewable-nuclear configurations in terms of cost, with ranges between $1B and $10B in 2023 USDs compared to $40B+ for fully renewable configurations. Of the nuclear technologies, small modular reactors performed better economically than large-scale nuclear models due to lower projected capital costs, and both performed better than the microreactor models. These results demonstrate the applicability of firm, dispatchable electricity resources from baseload generators like nuclear power plants for operating facilities that run at constant power without daily variability.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Ultraefficient resistance switching between charge ordered phases in 1 T -TaS 2 with a single picosecond electrical pulse

Progress in high-performance computing demands significant advances in memory technology. Among novel memory technologies that promise efficient device operation on a sub-ns timescale, resistance switching between charge ordered phases of 1T-TaS 2 has shown to be potentially useful for development of high-speed, energy efficient nonvolatile memory devices. Measurement of the electrical operation of such devices in the picosecond regime is technically challenging and hitherto still largely unexplored. Here, we use an optoelectronic “laboratory-on-a-chip” experiment for measurement of ultrafast memory switching, enabling accurate measurement of electrical switching parameters with 100 fs temporal resolution. Photoexcitation and electro-optic sampling on a (Cd,Mn)Te substrate are used to generate and, subsequently, measure electrical pulse propagation with intra-band excitation and sub-gap probing, respectively. We demonstrate high contrast nonvolatile resistance switching from high to low resistance states of a 1T-TaS 2 device using single sub-2ps electrical pulses. Using detailed modeling, we find that the switching energy density per unit area is exceptionally small, E A =9.4 fJ/μm 2 . Finally, the speed and energy efficiency of an electronic “write” process place the 1T-TaS 2 devices into a category of their own among new generation nonvolatile memory devices.

42 ENGINEERING↗

Bias-free terahertz generation from a silicon-compatible photoconductive emitter operating at telecommunication wavelengths

Here, we present a telecommunication-compatible bias-free photoconductive terahertz emitter composed of a bilayer InAs structure directly grown on a high-resistivity silicon substrate. The bilayer InAs structure includes p + -doped and undoped InAs layers, inducing a strong built-in electric field that enables terahertz generation without requiring any external bias voltage. A large-area plasmonic nanoantenna array is used to enhance and confine optical generation inside the photoconductive region with the highest built-in electric field, leading to the generation of a strong ultrafast photocurrent and broadband terahertz radiation. Thanks to a higher terahertz transmission through the silicon substrate and a shorter carrier lifetime in the InAs layers grown on silicon, higher signal-to-noise ratios are achieved at high terahertz frequencies compared with previously demonstrated bias-free terahertz emitters realized on GaAs. In addition to compatibility with silicon integrated optoelectronic platforms, the presented bias-free photoconductive emitter provides more than a 6 THz radiation bandwidth with more than 100 dB dynamic range when used in a terahertz time-domain spectroscopy system.

42 ENGINEERING↗

Electric fields imbue enzyme reactivity by aligning active site fragment orbitals

It is broadly recognized that intramolecular electric fields, produced by the protein scaffold and acting on the active site, facilitate enzymatic catalysis. This field effect can be described by several theoretical models, each of which is intuitive to varying degrees. In this contribution, we show that a fundamental effect of electric fields is to generate electrostatic potentials that facilitate the energetic alignment of reactant frontier orbitals. We apply this model to demystify the impact of electric fields on high-valent iron–oxo heme proteins: catalases, peroxidases, and peroxygenases/monooxygenases. Specifically, we show that this model easily accounts for the observed field-induced changes to the spin distribution within peroxidase active sites and explains the transition between epoxidation and hydroxylation pathways seen in Cytochrome P450 active site models. Thus, for the intuitive interpretation of the chemical effect of the field, the strategy involves analyzing the response of the orbitals of active site fragments, and their energetic alignment. We note that the energy difference between fragment orbitals involved in charge redistribution acts as a measure for the chemical hardness/softness of the reactive complex. This measure, and its sensitivity to electric fields, offers a single parameter model from which to quantitatively assess the effects of electric fields on reactivity and selectivity. Thus, the model provides an additional perspective to describe electrostatic preorganization and offers ways for its manipulation.

59 BASIC BIOLOGICAL SCIENCES↗

The Effect of Power Electronic Loads on Western Interconnection Stability

The prevalence of power electronics in the bulk power system is increasing rapidly in both the generation and consumption of electricity. This work focuses on the effect of changing load composition - specifically the transition from single phase air conditioner motors to power electronics backed air conditioners - on power system stability. Various transmission and generation contingency events for the Western Interconnection were simulated using Positive Sequence Load Flow software and planning models from the Western Electricity Coordinating Council. In general, an increased proportion of power electronic load leads to more instability. For some specific faults resulting in fault-induced delayed voltage recovery, transitioning to higher proportions of power electronic loads helps expedite system recovery. These results demonstrate that load composition should be examined in conjunction with generation composition when evaluating system stability.

FIDVR↗

Regulatory and Technical Challenges and Barriers to Adoption of Distributed Wind Energy in Agricultural Settings

Distributed wind (DW) energy development can benefit agricultural landowners through the possibility of improved resilience of electrical service from onsite generation and associated economic benefits. DW development currently faces technical and regulatory challenges related to interconnection of projects with distribution or transmission equipment on the main electrical grid. A review was conducted of barriers to adoption for agricultural DW projects and potential roles of various stakeholders in addressing them. One major barrier is that the unique characteristics of wind energy generation such as its variability and intermittency, may require upgrades for the whole power line, which can lead to prohibitive cost burdens on individual interconnection customers. Another barrier is compliance with federal, state, or utility-level regulations that require technology-agnostic, industry-standard equipment that is often not technically realistic for DW projects. DW developers, grid infrastructure owner-operators, regulators, and standards publishers can work together to address these challenges and facilitate DW development.

17 WIND ENERGY↗

Expanding the momentum field of view in angle-resolved photoemission systems with hemispherical analyzers

In photoelectron spectroscopy, the measured electron momentum range is intrinsically related to the excitation photon energy. Low photon energies <10 eV are commonly encountered in laser-based photoemission and lead to a momentum range that is smaller than the Brillouin zones of most materials. This can become a limiting factor when studying condensed matter with laser-based photoemission. An additional restriction is introduced by widely used hemispherical analyzers that record only electrons photoemitted in a solid angle set by the aperture size at the analyzer entrance. Here, we present an upgrade to increase the effective solid angle that is measured with a hemispherical analyzer. We achieve this by accelerating the photoelectrons toward the analyzer with an electric field that is generated by a bias voltage on the sample. Our experimental geometry is comparable to a parallel plate capacitor, and therefore, we approximate the electric field to be uniform along the photoelectron trajectory. With this assumption, we developed an analytic, parameter-free model that relates the measured angles to the electron momenta in the solid and verify its validity by comparing with experimental results on the charge density wave material TbTe3. By providing a larger field of view in momentum space, our approach using a bias potential considerably expands the flexibility of laser-based photoemission setups.

36 MATERIALS SCIENCE↗

Cryogenic C-band wavelength division multiplexing system using an AIM Photonics Foundry process design kit

Cryogenic environments make superconducting computing possible by reducing thermal noise, electrical resistance and heat dissipation. Heat generated by the electronics and thermal conductivity of electrical transmission lines to the outside world constitute two main sources of thermal load in such systems. As a result, higher data rates require additional transmission lines which come at an increasingly higher cooling power cost. Hybrid or monolithic integration of silicon photonics with the electronics can be the key to higher data rates and lower power costs in these systems. We present a 4-channel wavelength division multiplexing photonic integrated circuit (PIC) built from modulators in the AIM Photonics process development kit (PDK) that operate at 25 Gbps at room temperature and 10 Gbps at 40 K. We further demonstrate 2-channel operation for 20 Gbps aggregate data rate at 40 K using two different modulators/wavelengths, with the potential for higher aggregate bit rates by utilizing additional channels.

42 ENGINEERING↗

Produced Water and Waste Heat-aided Blowdown Water Treatment: Using Chemical and Energy Synergisms for Value Creation

The project objective was to develop a cooling blowdown water (BDW) treatment process utilizing produced water (PW) and low-grade heat to maximize water reuse and saleable by-product generation while reducing chemical and energy footprints of the treatment. The proposed treatment process consists of mixing, softening, organics and suspended solids removal, reverse osmosis (RO), thermal desalination, and brine electrolysis. BDW samples collected from a local coal-fired power plant and PW samples from two shale gas production wells were used in this study. Each treatment unit was first designed and tested to quantify its treatment efficiency, and its chemical and energy requirements. In addition, a process model was developed and model simulations were conducted based on the experimental results and literature data to optimize the treatment process. A techno-economic analysis was conducted to quantify chemical and energy savings as well as production of 10-lb brine as a saleable product. With the field-collected BDW and PW samples, mixing experiments determined a volumetric mixing ratio 10:1 (BDW:PW) resulted in the best performance of multivalent ions removal and largest chemical savings for softening. Softening of the BDW/PW mixtures using alkaline chemicals (Na 2 CO 3 and NaOH) achieved 95%-100% removal of scaling-forming cations (Ca, Mg, Fe, Ba, Sr) and 60% of silicon, and 10% of total organic carbon (TOC). The mixing and softening treatments yielded an effluent with total dissolved solids (TDS) concentration of 23 g/L. Activated carbon (AC) filtration removed TOC to a low level (< 3 mg/L) and further removed remaining scale-forming divalent metals and silica from the softened water. The AC filtration resulted in a slight reduction of TDS from 23 g/L to 20 g/L, leaving behind only mostly monovalent ions (i.e., sodium and chloride) in the filtered water. These pretreatments yielded a feed water that met the criteria of the downstream reverse osmosis (RO) to prevent membrane fouling. A cross-flow RO system was used to further concentrate the TDS of the AC effluent. Various factors including TDS, pH, and applied pressure were examined and optimal conditions were determined for the co-treatment process. An integrated process consisting of mixing, softening, AC filtration and RO was used to treat a continuous flow (0.25 – 1.2 L/min, or 0.07 – 0.32 gpm) and successfully generated RO permeate as product water (TDS < 0.5 g/L) for reuse in cooling operation, and a concentrate (TDS ~ 45 g/L) to be further treated in a thermal desalination unit. These flow rates meet the FOA’s criterion of 0.01 – 1 gpm. Overall, the co-treatment of BDW/PW allowed shorter ramp-up time compared to treatment of BDW alone. It resulted in 40% and 55% savings of Na 2 CO 3(s) and NaOH, respectively, compared to treating the BDW and PW individually for the same level of softening. The co-treatment also resulted in a 29% energy saving compared to treatment of BDW only for the level of TDS concentration. A thermal desalination system was designed using CFD simulations and manufactured in the WVU Innovation Hub for further treatment of the RO concentrate to generate 10-lb brine. The system has a design flow rate of 2 gpm and has been successfully tested. A bench-scale brine electrolysis system was developed for on-site generation of chlorine/hypochlorite (Cl 2 /OCl - ) and caustic soda (NaOH) as useful chemicals for the co-treatment process. Using salt solutions (0.5 M and 1 M), the system achieved faradaic efficiencies of 93%-97% and 70%-77% for caustic soda and chlorine/hypochlorite generation, respectively. An economic analysis showed that the electricity costs for on-site generation of these chemicals were significantly lower than the chemical prices offered by suppliers. An industrial-scale process model consisting of mixing, softening, AC filtration, RO, thermal desalination, and brine electrolysis was developed using the Aspen Plus V9 in conjunction with Aspen Custom Modeler V9. The model serves as a solvable Aspen Plus model and as basis to form the costing infrastructure. In addition, techno-economic analysis considering capital, operating, and transportation costs was conducted. An optimization solution showed that produced water for mixing is still advantageous in low quantities. The optimum solution approaches a leveled cost of water (LCW) of 2 $/m 3 which becomes cost competitive with nominal water treatment prices.

20 FOSSIL-FUELED POWER PLANTS↗

Stability and Characteristics of Lower-hybrid Drift Waves: Dependence on Electron Beta and Cross-field Relative Drift

Lower-hybrid drift waves (LHDWs) are frequently observed microinstabilities in both space and laboratory plasmas. Despite decades of study, the relationship between electrostatic (ES-LHDW) and electromagnetic (EM-LHDW) variants and the plasma parameters controlling their stability remains unclear. Here, we systematically examine LHDW behavior by solving the local linear dispersion relation over a wide range of plasma and field conditions. Our results demonstrate that ES-LHDWs and EM-LHDWs are not distinct modes but rather two different regimes of the same drift wave whose character evolves smoothly with electron beta (β e ) and the cross-field electron drift velocity relative to ions, normalized to the ion sound speed (u 0x /C s ). The nature of the waves changes from electrostatic to electromagnetic when β e increases. Growth rates increase with u 0x /C s but decrease with β e , while the most unstable wavelength remains nearly universal, with kρ e ∼ 0.8 (k is the magnitude of the wave vector and ρ e is the electron gyroradius). We further present quasi-linear estimates of nonlinear saturation properties, including energy partition among electric fields, magnetic fields, and particle kinetic responses. We show that ES-LHDWs reach higher electric-field saturation amplitudes, whereas EM-LHDWs generate strong magnetic perturbations and parallel electric fields that may enable efficient particle heating. Comparisons with the classical model reveal that retaining electromagnetic effects is essential for accurate predictions of frequency, growth rate, and the propagation angle. These findings provide a unified framework for understanding LHDWs across diverse collisionless plasma environments, including current sheets of magnetic reconnection, shear layers, collisionless shocks, and boundary regions.

Solar coronal waves↗

Supervisory genset control in range-extended electric vehicle

A controls system for a range-extended electric vehicle comprising an overall system control unit, an engine control module configured to control a range extender of the range-extended electric vehicle, power electronics configured to control a generator of the range-extended electric vehicle, and a supervisory control module coupled between the overall system control unit and the engine control module and the power electronics, the supervisory control module configured to receive information from the overall system control unit and provide commands to the engine control module and the power electronics.

Li, Ke↗

Role of Electric Vehicles in the U.S. Power Sector Transition: A System-Level Perspective

After over a century of petroleum dominance many anticipate that electrification could disrupt the transportation energy landscape. At the same time, the electric power systems are undergoing profound changes: variable renewables are displacing conventional generation sources; distributed generation is disrupting utility business models; energy storage and other new technologies are emerging; and the traditional system based on the premise that generation is dispatched to match an inelastic demand is evolving to create a system with greater participation in power system planning and operations from traditionally passive consumers. In this context, it is important to understand how transportation electrification will impact electricity demand and in turn electricity supply, including changes in the load shapes that characterize the system and the opportunity to leverage flexible electric vehicle (EV) charging to better integrate demand and supply. Assessing the impacts of electrification on the energy system requires an understanding of how it might impact the amount and shape of electricity consumption, and how this electricity can be supplied. In particular, increased adoption of electric vehicles introduces a new source of demand altogether, potentially very flexible. Moreover, electrification could shift the consumption of natural gas between sectors, thereby affecting the economics for natural gas-fired generation relative to other electricity generation options. Several factors will impact the evolution of the power system under a widespread electrified future, which, in turn, could have far-reaching effects on future energy costs and emissions.

47 OTHER INSTRUMENTATION↗

Addressing the Safety of Next-Generation Batteries

Owing to increasing demand for low-cost energy storage with secure material supply chains, the battery community is approaching a pivotal shift beyond conventional lithium-ion (Li-ion) towards next-generation cells. Technologies that include alkali-metal anodes, solid electrolytes and earth-abundant materials such as sodium (Na) and sulfur (S) are reaching commercialization in cells. The abuse tolerance and thermal runaway hazards of such technologies diverge from conventional Li-ion cells. Consequently, designing safe batteries with next-generation materials requires a holistic approach to characterize cells and to understand their responses to abuse conditions from the beginning to the end of life. Here we provide a Perspective on how the safety and abuse tolerance of cells are likely to change for up-and-coming technologies; challenges and opportunities for reimagining safe cell and battery designs; gaps in our knowledge; capabilities for understanding the hazards of thermal runaway and how to address them; how standard abuse tests may need to adapt to new challenges; and how research needs to support affected professionals, from pack designers to first responders, to manage hazards and ensure safe roll-out of next-generation cells into applications like electric vehicles (EVs). Finally, given the large number of next-generation technologies being explored, we encourage giving priority to safety-focused research in proportion to the rate of manufacturing scale-up of each specific technology.

25 ENERGY STORAGE↗

On the impact of tidal generation and energy storage integration in PV-rich electric distribution systems

Deep decarbonization of power system operations requires the maximal utilization of available renewable resources. At distribution-level operations, however, grid operators can face numerous challenges in integrating renewables at scale owing to the inherent intermittence of renewable energy resources. These include phenomena such as voltage fluctuations, which are typically mitigated through control actuators such as on-load tap changers (OLTC) as well as energy storage devices, such as battery energy storage systems (BESS). On the one hand, high intermittence of the available renewable portfolio may require increasingly aggressive control of actuators, thereby accelerating the probability of equipment failure. On the other hand, integrating BESS operations and having a diverse renewable generation portfolio can typically help stagger power/energy flow to mitigate the aforementioned adverse impacts. In this paper, we employ a Bayesian framework for equipment lifetime estimation to understand the impact of including tidal energy resources and BESS in distribution system operations for feeders having substantial distribution photovoltaic generation. Our results indicate that while tidal energy alone may slightly decrease equipment reliability, the adverse impact on reliability is significantly magnified by a generation portfolio consisting of tidal generation and photovoltaic generation. Here, we also study the tidal and photovoltaic hosting capacity problem with and without energy storage systems using equipment reliability as an added constraint. We conclude that energy storage increases the reliability-constrained hosting capacity of the distribution system.

14 SOLAR ENERGY↗