Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “EYES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Preclinical Assessment of Volumetric Modulated Arc Therapy for Total Marrow Irradiation

Purpose: A preclinical investigation was undertaken to explore a treatment technique for total marrow irradiation using RapidArc, a volumetric modulated arc technique. Materials and Methods: Computed tomography datasets of 5 patients were included. Plans with eight overlapping coaxial arcs were optimized for 6-MV photon beams. Dose prescription was 12 Gy in 2 Gy per fraction, normalized so that 100% isodose covered 85% of the planning target volume (PTV). The PTV consisted of the whole skeleton (including ribs and sternum), from the top of the skull to the medium distal third of the femurs. Planning objectives for organs at risk (OARs) were constrained to a median dose <6 to 7 Gy. OARs included brain, eyes, oral cavity, parotids, thyroid, lungs, heart, kidneys, liver, spleen, stomach, abdominal cavity, bladder, rectum, and genitals. Pretreatment quality assurance consisted of portal dosimetry comparisons, scoring the delivery to calculation agreement with the gamma agreement index. Results: The median total body volume in the study was 57 liters (range, 49-81 liters), for an average diameter of 47 cm (range, 46-53 cm) and a total length ranging from 95 to 112 cm. The median PTV volume was 6.8 liters (range, 5.8-10.8 liters). The mean dose to PTV was 109% (range, 107-112%). The global mean of median dose to all OARs was 4.9 Gy (range, 4.5-5.1 Gy over the 5 patients). The individual mean of median doses per organ ranged from 2.3 Gy (oral cavity) to 7.3 Gy (bowels cavity). Preclinical quality assurance resulted in a mean gamma agreement index of 94.3 {+-} 5.1%. The delivery time measured from quality assurance runs was 13 minutes. Conclusion: Sparing of normal tissues with adequate coverage of skeletal bones was shown to be feasible with RapidArc. Pretreatment quality assurance measurements confirmed the technical agreement between expected and actually delivered dose distributions, suggesting the possibility of incorporating this technique in the treatment options for patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Total Marrow Irradiation With RapidArc Volumetric Arc Therapy

Purpose: To develop a volumetric arc therapy (VMAT)-total marrow irradiation (TMI) technique for patients with hematologic malignancies. Methods and Materials: VMAT planning was performed for 6 patients using RapidArc technology. The planning target volume consisted of all the bones in the body from the head to the mid-femur, excluding the extremities, except for the humerus, plus a 3.0-mm margin. The organs at risk included the lungs, heart, liver, kidneys, bowels, brain, eyes, and oral cavity. The VMAT-TMI technique consisted of three plans: the head and neck, the chest, and the pelvis, each with three 330{sup o} arcs. The plans were prescribed to ensure, at a minimum, 95% planning target volume dose coverage with the prescription dose (percentage of volume receiving dose of {>=}12 Gy was 95%). The treatments were delivered and verified using MapCheck and ion chamber measurements. Results: The VMAT-TMI technique reported in the present study provided comparable dose distributions with respect to the fixed gantry linear accelerator intensity-modulated TMI. RapidArc planning was less subjective and easier, and, most importantly, the delivery was more efficient. RapidArc reduced the treatment delivery time to approximately 18 min from 45 min with the fixed gantry linear accelerator intensity-modulated TMI. When the prescription dose coverage was reduced to 85% from 95% and the mandible and maxillary structures were not included in the planning target volume as reported in a tomotherapy study, a considerable organ at risk dose reduction of 4.2-51% was observed. The average median dose for the lungs and lenses was reduced to 5.6 Gy from 7.2 Gy and 2.4 Gy from 4.5 Gy, respectively. Conclusion: The RapidArc VMAT technique improved the treatment planning, dose conformality, and, most importantly, treatment delivery efficiency. The results from our study suggest that the RapidArc VMAT technology can be expected to facilitate the clinical transition of TMI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development and Evaluation of Multiple Isocentric Volumetric Modulated Arc Therapy Technique for Craniospinal Axis Radiotherapy Planning

Purpose: To develop and compare a volumetric modulated arc therapy (VMAT) technique with conventional radiotherapy for craniospinal irradiation with respect to improved dose conformity and homogeneity in the planning target volume (PTV) and to reduced dose to organs at risk (OAR). Methods and Materials: Conventional craniospinal axis radiotherapy plans of 5 patients were acquired. The median (range) length of the PTV was 58.9 (48.1-83.7) cm. The 6-MV VMAT plans were inversely planned with one isocenter near the base of the brain and the minimum number of isocenters required for the specified lengths of spine. The plans were optimized with high weighting for PTV coverage and low weighting for OAR sparing. Conformity and heterogeneity indices, dose-volume histograms, mean doses, and non-PTV integral doses from the two plans (prescription dose 23.4 Gy in 13 fractions) were compared. Results: The median (range) conformity index of VMAT was 1.22 (1.09-1.45), compared with 1.69 (1.44-2.67) for conventional plans (p = 0.04). The median (range) heterogeneity index was also lower for VMAT compared with conventional plans: 1.04 (1.03-1.07) vs. 1.12 (1.09-1.19), respectively (p = 0.04). A significant reduction of mean and maximum doses was observed in the heart, thyroid, esophagus, optic nerves, and eyes with VMAT when compared with conventional plans. A decrease in body V{sub 10Gy} was observed, but for 4 of 5 patients non-PTV integral dose was increased with VMAT when compared with the conventional plans. Conclusions: A VMAT technique to treat the craniospinal axis significantly reduces OAR dose, potentially leading to lower late organ toxicity. However, this is achieved at the expense of increased low-dose volumes, which is inherent to the technique, carrying a potentially increased risk of secondary malignancies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Kilovoltage Imaging Doses in the Radiotherapy of Pediatric Cancer Patients

Purpose: To investigate doses induced by kilovoltage cone-beam computed tomography (kVCBCT) to pediatric cancer patients undergoing radiotherapy, as well as strategies for dose reduction. Methods and Materials: An EGS4 Monte Carlo code was used to calculate three-dimensional dose deposition due to kVCBCT on 4 pediatric cancer patients. Absorbed doses to various organs were analyzed for both half-fan and full-fan modes. Clinical conditions, such as distance from organ at risk (OAR) to CBCT field border, kV peak energy, and testicular shielding, were studied. Results: The mean doses induced by one CBCT scan operated at 125 kV in half-fan mode to testes, liver, kidneys, femoral heads, spinal cord, brain, eyes, lens, and optical nerves were 2.9, 4.7, 7.7, 10.5, 8.8, 7.6, 7.7, 7.8, and 7.2 cGy, respectively. Increasing the distances from OARs to CBCT field border greatly reduced the doses to OARs, ranging from 33% reduction for spinal cord to 2300% reduction for testes. As photon beam energy increased from 60 to 125 kV, the dose increase due to kVCBCT ranged from 170% for lens to 460% for brain and spinal cord. A testicular shielding made of 1-cm cerrobend could reduce CBCT doses down to 31%, 51%, 68%, and 82%, respectively, for 60, 80, 100, and 125 kV when the testes lay within the CBCT field. Conclusions: Generally speaking, kVCBCT deposits much larger doses to critical structures in children than in adults, usually by a factor of 2 to 3. Increasing the distances from OARs to CBCT field border greatly reduces doses to OARs. Depending on OARs, kVCBCT-induced doses increase linearly or exponentially with photon beam energy. Testicular shielding works more efficiently at lower kV energies. On the basis of our study, it is essential to choose an appropriate scanning protocol when kVCBCT is applied to pediatric cancer patients routinely.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Volumetric Modulated Arc-Based Hypofractionated Stereotactic Radiotherapy for the Treatment of Selected Intracranial Arteriovenous Malformations: Dosimetric Report and Early Clinical Experience

Purpose: To evaluate, with a dosimetric and clinical feasibility study, RapidArc (a volumetric modulated arc technique) for hypofractionated stereotactic radiotherapy treatment of large arteriovenous malformations (AVMs). Methods and Materials: Nine patients were subject to multimodality imaging (magnetic resonance, computed tomography, and digital subtraction angiography) to determine nidus and target volumes, as well as involved organs at risk (optical structures, inner ear, brain stem). Plans for multiple intensity-modulated arcs with a single isocenter were optimized for a fractionation of 25 Gy in 5 fractions. All plans were optimized for 6-MV photon beams. Dose-volume histograms were analyzed to assess plan quality. Delivery parameters were reported to appraise technical features of RapidArc, and pretreatment quality assurance measurements were carried out to report on quality of delivery. Results: Average size of AVM nidus was 26.2 cm{sup 3}, and RapidArc plans provided complete target coverage with minimal overdosage (V{sub 100%} = 100% and V{sub 110%} < 1%) and excellent homogeneity (<6%). Organs at risk were highly spared. The D{sub 1%} to chiasm, eyes, lenses, optic nerves, and brainstem (mean {+-} SD) was 6.4 {+-} 8.3, 1.9 {+-} 3.8, 2.3 {+-} 2.2, 0.7 {+-} 0.9, 4.4 {+-} 7.2, 12.2 {+-} 9.6 Gy, respectively. Conformity index (CI{sub 95%}) was 2.2 {+-} 0.1. The number of monitor units per gray was 277 {+-} 45, total beam-on time was 2.5 {+-} 0.3 min. Planning vs. delivery {gamma} pass rate was 98.3% {+-} 0.9%. None of the patients developed acute toxicity. With a median follow-up of 9 months, 3 patients presented with deterioration of symptoms and were found to have postradiation changes but responded symptomatically to steroids. These patients continue to do well on follow-up. One patient developed headache and seizures, which was attributed to intracranial bleed, confirmed on imaging. Conclusion: Hypofractionated stereotactic radiotherapy can be successfully delivered using the RapidArc form of volumetric arc technology for intracranial AVMs. The quality of delivery and calculated parameters are in agreement with each other and are in line with published reports for other sites.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Patient-Specific Three-Dimensional Concomitant Dose From Cone Beam Computed Tomography Exposure in Image-Guided Radiotherapy

Purpose: The purpose of the present study was to quantify the concomitant dose received by patients undergoing cone beam computed tomography (CBCT) scanning in different clinical scenarios as a part of image-guided radiotherapy (IGRT) procedures. Methods and Materials: We calculated the three-dimensional concomitant dose received as a result of CBCT scans in 6 patients representing different clinical scenarios: two pelvis, two head and neck, and two chest. We assessed the effect that a daily on-line IGRT strategy would have on the patient dose distribution, assuming 40 CBCT scans throughout the treatment course. The additional dose to the planning target volume margin region was also estimated. Results: In the pelvis, a single CBCT scan delivered a mean dose to the femoral heads of 2-6 cGy and the rectum of 1-2 cGy. An additional dose to the planning target volume was within 1-3 cGy. In the chest, the mean dose to the planning target volume varied from 2.5 to 5 cGy. The lung and spinal cord planning organ at risk volume received {<=}4 cGy and {<=}5 cGy, respectively. In the head and neck, a single CBCT scan delivered a mean dose of 0.3 cGy, with bony structures receiving 0.5-0.8 cGy. The femoral heads received an additional dose of 1.5-2.5 Gy. A reduction of 20-30% in the mean dose to the organs at risk was achieved using bowtie filtration. In the head and neck, the dose to the eyes and brainstem was eliminated by decreasing the craniocaudal field size. Conclusions: The additional dose from on-line IGRT procedures can be clinically relevant. The organ dose can be significantly reduced with the use of appropriate patient-specific settings. The concomitant dose from CBCT should be accounted for and the acquisition settings optimized for optimal IGRT strategies on a patient basis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric Study of Current Treatment Options for Radiotherapy in Retinoblastoma

Purpose: To determine the best treatment technique for patients with retinoblastoma requiring radiotherapy to the whole eye. Methods and Materials: Treatment plans for 3 patients with retinoblastoma were developed using 10 radiotherapy techniques including electron beams, photon beam wedge pair (WP), photon beam three-dimensional conformal radiotherapy (3D-CRT), fixed gantry intensity-modulated radiotherapy (IMRT), photon volumetric arc therapy (VMAT), fractionated stereotactic radiotherapy, and helical tomotherapy (HT). Dose-volume analyses were carried out for each technique. Results: All techniques provided similar target coverage; conformity was highest for VMAT, nine-field (9F) IMRT, and HT (conformity index [CI] = 1.3) and lowest for the WP and two electron techniques (CI = 1.8). The electron techniques had the highest planning target volume dose gradient (131% of maximum dose received [D{sub max}]), and the CRT techniques had the lowest (103% D{sub max}) gradient. The volume receiving at least 20 Gy (V{sub 20Gy}) for the ipsilateral bony orbit was lowest for the VMAT and HT techniques (56%) and highest for the CRT techniques (90%). Generally, the electron beam techniques were superior in terms of brain sparing and delivered approximately one-third of the integral dose of the photon techniques. Conclusions: Inverse planned image-guided radiotherapy delivered using HT or VMAT gives better conformity index, improved orbital bone and brain sparing, and a lower integral dose than other techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Longitudinal proteomics analysis in the immediate microenvironment of islet allografts during progression of rejection

The applicability and benefits of pancreatic islet transplantation are limited due to various issues including the need to avoid immune-mediated rejection. In the present study, we used our experimental platform of allogeneic islet transplant in the anterior chamber of the eye (ACE-platform) to longitudinally monitor the progress of rejection in mice and obtain aqueous humor samples representative of the microenvironment of the graft for accurately-timed proteomic analyses. LC-MS/MS-based proteomics performed on such mass-limited samples (~5 μL) identified a total of 1296 proteins. Various analyses revealed distinct protein patterns associated with the mounting of the inflammatory and immune responses and their evolution with the progression of the rejection. Pathway analyses indicated predominant changes in cytotoxic functions, cell movement, and innate and adaptive immune responses. Furthermore, network prediction analyses revealed transition from humoral to cellular immune response and exacerbation of pro-inflammatory signaling. One of the proteins identified by this localized proteomics as a candidate biomarker of islet rejection, Cystatin 3, was further validated by ELISA in the aqueous humor. This study provides (1) experimental evidence demonstrating the feasibility of longitudinal localized proteomics using small aqueous humor samples and (2) proof-of-concept for the discovery of biomarkers of impending immune attack from the immediate local microenvironment of ACE-transplanted islets.

59 BASIC BIOLOGICAL SCIENCES↗

Preliminary Results of Helical Tomotherapy in Patients with Complex-Shaped Meningiomas Close to the Optic Pathway

Meningiomas are the most common benign intracranial tumor. Meningiomas close to the optic pathway represent a treatment challenge both for surgery and radiotherapy. The aim of this article is to describe early results of helical tomotherapy treatment in complex-shaped meningiomas close to the optic pathway. Twenty-eight patients were consecutively treated. All patients were immobilized with a thermoplastic head mask and planned with the aid of a magnetic resonance imaging-computed tomography fusion. All treatments included daily image guidance. Pretreatment symptoms and acute toxicity were recorded. Median age was 57.5 years, and 92.8% patients had Eastern Cooperative Oncology Group performance status scale {<=}1. The most common localizations were the sella turcica, followed by the cavernous sinus and the sphenoid. The most common symptoms were derived from cranial nerve deficits. Tomotherapy was administered as primary treatment in 35.7% of patients, as an adjuvant treatment in 32.4%, and as a rescue treatment after postsurgical progression in 32.1% patients. Most patients were either inoperable or Simpson IV. Total dose varied between 5000 and 5400 cGy; fractionation varied between 180 and 200 cGy. Median dose to the planning target volume was 51.7 Gy (range, 50.2-55.9 Gy). Median coverage index was 0.89 (range, 0.18-0.97). Median homogeneity index was 1.05 (range, 1-1.12). Acute transient toxicity was grade 1 and included headache in 35.7% patients, ocular pain/dryness in 28.5%, and radiation dermatitis in 25%. Thus far, with a maximal follow-up of 3 years, no late effects have been seen and all patients have a radiological stabilization of the disease. Helical tomotherapy offered a safe and effective therapeutic alternative for patients with inoperable or subtotally resected complex-shaped meningiomas close to the optic pathway. Acceptable coverage and homogeneity indexes were achieved with appropriate values for maximal doses delivered to the eyes, lenses, and chiasm, despite the proximity of the tumor to these structures.

61 RADIATION PROTECTION AND DOSIMETRY↗

Bowel sparing in pediatric cranio-spinal radiotherapy: a comparison of combined electron and photon and helical TomoTherapy techniques to a standard photon method

The aim of this study was to compare the dose to organs at risk (OARs) from different craniospinal radiotherapy treatment approaches available at the Northern Centre for Cancer Care (NCCC), with a particular emphasis on sparing the bowel. Method: Treatment plans were produced for a pediatric medulloblastoma patient with inflammatory bowel disease using 3D conformal 6-MV photons (3DCP), combined 3D 6-MV photons and 18-MeV electrons (3DPE), and helical photon TomoTherapy (HT). The 3DPE plan was a modification of the standard 3DCP technique, using electrons to treat the spine inferior to the level of the diaphragm. The plans were compared in terms of the dose-volume data to OARs and the nontumor integral dose. Results: The 3DPE plan was found to give the lowest dose to the bowel and the lowest nontumor integral dose of the 3 techniques. However, the coverage of the spine planning target volume (PTV) was least homogeneous using this technique, with only 74.6% of the PTV covered by 95% of the prescribed dose. HT was able to achieve the best coverage of the PTVs (99.0% of the whole-brain PTV and 93.1% of the spine PTV received 95% of the prescribed dose), but delivered a significantly higher integral dose. HT was able to spare the heart, thyroid, and eyes better than the linac-based techniques, but other OARs received a higher dose. Conclusions: Use of electrons was the best method for reducing the dose to the bowel and the integral dose, at the expense of compromised spine PTV coverage. For some patients, HT may be a viable method of improving dose homogeneity and reducing selected OAR doses.

61 RADIATION PROTECTION AND DOSIMETRY↗

Clinical applications of 3-dimensional printing in radiation therapy

Three-dimensional (3D) printing is suitable for the fabrication of complex radiotherapy bolus. Although investigated from dosimetric and feasibility standpoints, there are few reports to date of its use for actual patient treatment. This study illustrates the versatile applications of 3D printing in clinical radiation oncology through a selection of patient cases, namely, to create bolus for photon and modulated electron radiotherapy (MERT), as well as applicators for surface high-dose rate (HDR) brachytherapy. Photon boluses were 3D-printed to treat a recurrent squamous cell carcinoma (SCC) of the nasal septum and a basal cell carcinoma (BCC) of the posterior pinna. For a patient with a mycosis fungoides involving the upper face, a 3D-printed MERT bolus was used. To treat an SCC of the nose, a 3D-printed applicator for surface brachytherapy was made. The structures' fit to the anatomy and the radiotherapy treatment plans were assessed. Based on the treatment planning computed tomography (CT), the size of the largest air gap at the interface of the 3D-printed structure was 3 mm for the SCC of the nasal septum, 3 mm for the BCC of the pinna, 2 mm for the mycosis fungoides of the face, and 2 mm for the SCC of the nose. Acceptable treatment plans were obtained for the SCC of the nasal septum (95% isodose to 99.8% of planning target volume [PTV]), the BCC of the pinna (95% isodose to 97.7% of PTV), and the mycosis fungoides of the face (90% isodose to 92.5% of PTV). For the latter, compared with a plan with a uniform thickness bolus, the one featuring the MERT bolus achieved relative sparing of all the organs at risk (OARs) distal to the target volume, while maintaining similar target volume coverage. The surface brachytherapy plan for the SCC of the nose had adequate coverage (95% isodose to 95.6% of clinical target volume [CTV]), but a relatively high dose to the left eye, owing to its proximity to the tumor. 3D printing can be implemented effectively in the clinical setting to create highly conformal bolus for photon and MERT, as well as applicators for surface brachytherapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Radiation shielding analysis of the concrete hutch of a long beamline of the Advanced Photon Source Upgrade project

The radiation shielding analysis of the external concrete enclosure of a feature long beamline of the Advanced Photon Source Upgrade project is described in this work. The beamline has 2 undulators that can operate in two different configurations and the source terms are estimated for the worst configuration using the SRW code in the OASYS package as well as the STAC8 code. The shielding analysis is carried out using the STAC8 code, and for the case of pink beam, with the FLUKA code also. Effective dose rates on contact with the outside surface of the concrete walls for pink, reflected full spectrum and monochromatic beams are calculated. For the monochromatic beams, 2 sets of discrete bandwidths (BW) from the Double Crystal Monochromator (DCM) and the full reflectance of the Double Multilayer Monochromator (DMM) are used. Further, due to the size of the direct beam and the energy domain of interest in the direct and scattered fields, the importance of the equivalent dose to the lens of the eye is discussed with respect to the shielding calculations of such facilities. The dose rates outside the concrete hutch in the lateral directions calculated using STAC8 is about 50% higher than the FLUKA results for the case of pink beam but may be considered as a reasonable agreement due to the differences in the calculational methodologies. Those dose rates in the lateral and forward directions are higher for the pink beam to allow full occupancy from the radiation protection point of view. For the full spectrum after 3 reflections, the effective dose rates are less than 0.5 Sv/h in the lateral direction but is higher in the forward region below about 22° with respect to the beam direction. For the DCM beams, except for the scenario with one mirror and 0.1%BW, all dose rates are less than 0.5 Sv/h outside the concrete hutch in the lateral directions. Here, the higher harmonics are what contributes to the dose outside the shield and the bandwidths assumed to derive the photon flux thus becomes important. The dose rates with the DMM are generally lower compared to the 0.1% BW DCM beam but are higher than the results obtained with XOP calculated bandwidths.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cytochrome P450 20A1 in zebrafish: Cloning, regulation and potential involvement in hyperactivity disorders

Cytochrome P450 (CYP) enzymes for which there is no functional information are considered “orphan” CYPs. Previous studies showed that CYP20A1, an orphan, is expressed in human hippocampus and substantia nigra, and in zebrafish (Danio rerio) CYP20A1 maternal transcript occurs in eggs, suggesting involvement in brain and in early development. Moreover, hyperactivity is reported in humans with chromosome 2 microdeletions including CYP20A1. We examined CYP20A1 in zebrafish, including impacts of chemical exposure on expression. Zebrafish CYP20A1 cDNA was cloned, sequenced, and aligned with cloned human CYP20A1 and predicted vertebrate orthologs. CYP20A1s share a highly conserved N-terminal region and unusual sequences in the I-helix and the heme-binding CYP signature motifs. CYP20A1 mRNA expression was observed in adult zebrafish organs including the liver, heart, gonads, spleen and brain, as well as the eye and optic nerve. Putative binding sites in proximal promoter regions of CYP20A1s, and response of zebrafish CYP20A1 to selected nuclear and xenobiotic receptor agonists, point to up-regulation by agents involved in steroid hormone response, cholesterol and lipid metabolism. There also was a dose-dependent reduction of CYP20A1 expression in embryos exposed to environmentally relevant levels of methylmercury. Morpholino knockdown of CYP20A1 in developing zebrafish resulted in behavioral effects, including hyperactivity and a slowing of the optomotor response in larvae. The results suggest that altered expression of CYP20A1 might be part of a mechanism linking methylmercury exposure to neurobehavioral deficits. The expanded information on CYP20A1 brings us closer to “deorphanization”, that is, identifying CYP20A1 functions and its roles in health and disease. - Highlights: • The “orphan” CYP20A1 was cloned from zebrafish and its sequence analyzed. • Knockdown of CYP20A1 reduced an optomotor response and elicited bursts of activity. • Effects of knockdown resemble some features of a microdeletion of CYP20A1 in human. • Expression of CYP20A1 was downregulated by the neurotoxicant methylmercury. • CYP20A1 may be involved in neurobehavioral processes and effects of some chemicals.

60 APPLIED LIFE SCIENCES↗

Chemical Form Matters: Differential Accumulation of Mercury Following Inorganic and Organic Mercury Exposures in Zebrafish Larvae

Mercury, one of the most toxic elements, exists in various chemical forms each with different toxicities and health implications. Some methylated mercury forms, one of which exists in fish and other seafood products, pose a potential threat, especially during embryonic and early postnatal development. Despite global concerns, little is known about the mechanisms underlying transport and toxicity of different mercury species. To investigate the impact of different mercury chemical forms on vertebrate development, we have successfully combined the zebrafish, a well-established developmental biology model system, with synchrotron-based X-ray fluorescence imaging. Our work revealed substantial differences in tissue-specific accumulation patterns of mercury in zebrafish larvae exposed to four different mercury formulations in water. Methylmercury species not only resulted in overall higher mercury burdens but also targeted different cells and tissues than their inorganic counterparts, thus revealing a significant role of speciation in cellular and molecular targeting and mercury sequestration. For methylmercury species, the highest mercury concentrations were in the eye lens epithelial cells, independent of the formulation ligand (chloride versus L-cysteine). For inorganic mercury species, in absence of L-cysteine, the olfactory epithelium and kidney accumulated the greatest amounts of mercury. However, with L-cysteine present in the treatment solution, mercuric bis-L-cysteineate species dominated the treatment, significantly decreasing uptake. Our results clearly demonstrate that the common differentiation between organic and inorganic mercury is not sufficient to determine the toxicity of various mercury species.

54 ENVIRONMENTAL SCIENCES↗

Femtosecond Laser Micro-structuring Of Transparent Materials And Its Ophthalmologic Applications

We have successfully fabricated in vitro femtosecond laser micro-incisions inside cornea and--for the first time--inside sclera mildly pre-cleared by a biocompatible and clinically safe (non-toxic) natural agent (replacive refractive index-matching 40%-glucose solution in water), with the tissues taken as fresh cool cuts of human cadaver eyes, and reported on basic operational conditions of the micro-surgical procedures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

New laser technologies in ophthalmology for normalisation of intraocular pressure and correction of refraction

We present the results of recent studies that develop principally new approaches to solving the problem of visual impairment and provide the basis for new laser technologies in ophthalmology for the treatment of glaucoma, myopia and hypermetropia. The considered theoretical models and optical methods for detecting laser-induced structural changes in eye tissues pave the way to the invention of control systems with feedback, providing efficient and safe laser treatment. (laser medicine)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling sequential context effects in diagnostic interpretation of screening mammograms

Prior research has shown that physicians’ medical decisions can be influenced by sequential context, particularly in cases where successive stimuli exhibit similar characteristics when analyzing medical images. This type of systematic error is known to psychophysicists as sequential context effect as it indicates that judgments are influenced by features of and decisions about the preceding case in the sequence of examined cases, rather than being based solely on the peculiarities unique to the present case. We determine if radiologists experience some form of context bias, using screening mammography as the use case. To this end, we explore correlations between previous perceptual behavior and diagnostic decisions and current decisions. We hypothesize that a radiologist’s visual search pattern and diagnostic decisions in previous cases are predictive of the radiologist’s current diagnostic decisions. To test our hypothesis, we tasked 10 radiologists of varied experience to conduct blind reviews of 100 four-view screening mammograms. Eye-tracking data and diagnostic decisions were collected from each radiologist under conditions mimicking clinical practice. Perceptual behavior was quantified using the fractal dimension of gaze scanpath, which was computed using the Minkowski–Bouligand box-counting method. To test the effect of previous behavior and decisions, we conducted a multifactor fixed-effects ANOVA. Further, to examine the predictive value of previous perceptual behavior and decisions, we trained and evaluated a predictive model for radiologists’ current diagnostic decisions. ANOVA tests showed that previous visual behavior, characterized by fractal analysis, previous diagnostic decisions, and image characteristics of previous cases are significant predictors of current diagnostic decisions. Additionally, predictive modeling of diagnostic decisions showed an overall improvement in prediction error when the model is trained on additional information about previous perceptual behavior and diagnostic decisions.

60 APPLIED LIFE SCIENCES↗