Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Direct detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Equalizing the Pixel Response of the Imaging Photoelectric Polarimeter Onboard the IXPE Mission

The Gas Pixel Detector is a gas detector, sensitive to the polarization of X-rays, currently flying onboard the Imaging X-ray Polarimetry Explorer (IXPE)—the first observatory dedicated to X-ray polarimetry. It detects X-rays and their polarization by imaging the ionization tracks generated by photoelectrons absorbed in the sensitive volume, and then reconstructing the initial direction of the photoelectrons. The primary ionization charge is multiplied and ultimately collected on a finely pixellated ASIC specifically developed for X-ray polarimetry. The signal of individual pixels is processed independently and gain variations can be substantial, of the order of 20%. Such variations need to be equalized to correctly reconstruct the track shape, and therefore its polarization direction. The method to do such equalization is presented here and is based on the comparison between the mean charge of a pixel with respect to the other pixels for equivalent events. The method is shown to finely equalize the response of the detectors onboard IXPE, allowing a better track reconstruction and energy resolution, and can in principle be applied to any imaging detector based on tracks.

79 ASTRONOMY AND ASTROPHYSICS↗

Evidence of a Dwarf Galaxy Stream Populating the Inner Milky Way Halo

Stellar streams produced from dwarf galaxies provide direct evidence of the hierarchical formation of the Milky Way. Here, we present the first comprehensive study of the LMS-1 stellar stream, that we detect by searching for wide streams in the Gaia EDR3 data set using the STREAMFINDER algorithm. This stream was recently discovered by Yuan et al. We detect LMS-1 as a 60° long stream to the north of the galactic bulge, at a distance of ~20 kpc from the Sun, together with additional components that suggest that the overall stream is completely wrapped around the inner Galaxy. Using spectroscopic measurements from the Large Sky Area Multi-Object Fiber Spectroscopic Telescope, the Sloan Digital Sky Survey, and the Apache Point Observatory Galactic Evolution Experiment, we infer that the stream is very metal-poor (<[Fe/H]> = –2.1) with a significant metallicity dispersion (σ [Fe/H] = 0.4), and it possesses a large radial velocity dispersion (σ v = 20 ± 4 km s–1 ). These estimates together imply that LMS-1 is a dwarf galaxy stream. The orbit of LMS-1 is close to polar, with an inclination of 75° to the galactic plane. Both the orbit and metallicity of LMS-1 are remarkably similar to the globular clusters NGC 5053, NGC 5024, and the stellar stream Indus. As a result, these findings make LMS-1 an important contributor to the stellar population of the inner Milky Way halo.

79 ASTRONOMY AND ASTROPHYSICS↗

Scaler Rates from the Pierre Auger Observatory: A New Proxy of Solar Activity

The modulation of low-energy galactic cosmic rays reflects interplanetary magnetic field variations and can provide useful information on solar activity. An array of ground-surface detectors can reveal the secondary particles, which originate from the interaction of cosmic rays with the atmosphere. In this work, we present an investigation of the low-threshold rate (scaler) time series recorded in 16 yr of operation by the Pierre Auger Observatory surface detectors in Malargüe, Argentina. Through an advanced spectral analysis, we detected highly statistically significant variations in the time series with periods ranging from the decadal to the daily scale. We investigate their origin, revealing a direct connection with solar variability. Thanks to their intrinsic very low noise level, the Auger scalers allow a thorough and detailed investigation of the galactic cosmic-ray flux variations in the heliosphere at different timescales and can, therefore, be considered a new proxy of solar variability.

79 ASTRONOMY AND ASTROPHYSICS↗

Degradation of Components After Exposure in a Biomass Pyrolysis System

X-ray diffraction, electron probe microanalysis, and scanning transmission electron microscopy with focused ion beam lift-out sample preparation techniques were used to study corrosion products in a 304L (UNS S30403) stainless steel fluidized-bed reactor segment from Iowa State University’s Pyrolysis Process Development Unit Facility. This reactor segment is particularly valuable because a detailed history of operation time, temperature, and biomass feedstock was available. As previously reported for a range of stainless steel pyrolysis-related equipment, external scaling and internal attack along alloy grain boundaries were observed. Here, the scaling was primarily associated with O, although S, Ca, K, Si, Mg, and P were also detected in the outer scale regions. However, unlike those other recent advanced characterization analyses, in this instance the internal alloy grain boundary attack was not directly related to S. Rather, only internal oxidation and localized nanoporosity were observed along the alloy grain boundaries, with associated local nanoscale Cr depletion and Ni enrichment. Mechanistic implications of this finding are discussed.

36 MATERIALS SCIENCE↗

Multiple lineages of Streptomyces produce antimicrobials within passalid beetle galleries across eastern North America

Some insects form symbioses in which actinomycetes provide defense against pathogens by making antimicrobials. The range of chemical strategies employed across these associations, and how these strategies relate to insect lifestyle, remains underexplored. We assessed subsocial passalid beetles of the species Odontotaenius disjunctus , and their frass (fecal material), which is an important food resource within their galleries, as a model insect/actinomycete system. Through chemical and phylogenetic analyses, we found that O. disjunctus frass collected across eastern North America harbored multiple lineages of Streptomyces and diverse antimicrobials. Metabolites detected in frass displayed synergistic and antagonistic inhibition of a fungal entomopathogen, Metarhizium anisopliae , and multiple streptomycete isolates inhibited this pathogen when co-cultivated directly in frass. These findings support a model in which the lifestyle of O. disjunctus accommodates multiple Streptomyces lineages in their frass, resulting in a rich repertoire of antimicrobials that likely insulates their galleries against pathogenic invasion.

59 BASIC BIOLOGICAL SCIENCES↗

Differential holography

Differential Holography technology measures the amplitude and/or phase of, e.g., an incident linearly polarized spatially coherent quasi-monochromatic optical field by optically computing the first derivative of the field and linearly mapping it to an irradiance signal detectable by an image sensor. This information recorded on the image sensor is then recovered by a simple algorithm. In some embodiments, an input field is split into two or more beams to independently compute the horizontal and vertical derivatives (using amplitude gradient filters in orthogonal orientations) for detection on one image sensor in separate regions of interest (ROIs) or on multiple image sensors. A third unfiltered beam recorded in a third ROI directly measures amplitude variations in the input field to numerically remove its contribution as noise before recovering the original wavefront using a numerical in algorithm. When combined, the measured amplitude and phase constitute a holographic recording of the incident optical field.

Ravizza, Frank↗

Autonomous Aerosol and Plasma Co‐Jet Printing of Metallic Devices at Ambient Temperature

Abstract Additive manufacturing of metallic materials holds the potential to revolutionize the fabrication of functional devices unattainable via traditional methods. Despite recent advancements, printing metallic materials typically requires thermal processing at elevated temperatures to form dense structures with desired properties, which presents a major challenge for direct printing and integration with temperature‐sensitive materials. Herein, a unique co‐jet printing (CJP) method is reported integrating an aerosol jet and a non‐thermal, atmospheric pressure plasma jet to enable concurrent aerosol deposition of metal nanoparticle inks and in situ sintering at ambient temperature. A machine learning algorithm is integrated with the CJP to perform real‐time defect detection and autonomous correction, enhancing the yield of printed films with high electrical conductivity from 44% to 94%. Concurrent printing and sintering eliminate the need for post‐printing processing, reducing the overall manufacturing time by multiple folds depending on product size. CJP enables direct printing of functional devices on a variety of temperature‐sensitive materials including biological materials. Direct printing of hydration sensors on living plant leaves is demonstrated for long‐duration monitoring of hydration level in the plant. The versatile CJP method opens tremendous opportunities to harmoniously integrate abiotic and biotic materials for emerging applications in wearable/implantable devices and biohybrid systems.

Du, Yipu [Department of Aerospace and Mechanical E↗

Single Entity Electrochemistry in Nanopore Electrode Arrays: Ion Transport Meets Electron Transfer in Confined Geometries

Electrochemical measurements conducted in confined volumes provide a powerful and direct means to address scientific questions at the nexus of nanoscience, biotechnology, and chemical analysis. How are electron transfer and ion transport coupled in confined volumes and how does understanding them require moving beyond macroscopic theories? Also, how do these coupled processes impact electrochemical detection and processing? We address these questions by studying a special type of confined-volume architecture, the nanopore electrode array, or NEA, which is designed to be commensurate in size with physical scaling lengths, such as the Debye length, a concordance that offers performance characteristics not available in larger scale structures. The experiments described here depend critically on carefully constructed nanoscale architectures that can usefully control molecular transport and electrochemical reactivity. We begin by considering the experimental constraints that guide the design and fabrication of zero-dimensional nanopore arrays with multiple embedded electrodes. These zero-dimensional structures are nearly ideal for exploring how permselectivity and unscreened ion migration can be combined to amplify signals and improve selectivity by enabling highly efficient redox cycling. Our studies also highlight the benefits of arrays, in that molecules escaping from a single nanopore are efficiently captured by neighboring pores and returned to the population of active redox species being measured, benefits that arise from coupling ion accumulation and migration. These tools for manipulating redox species are well-positioned to explore single molecule and single particle electron transfer events through spectroelectrochemistry, studies which are enabled by the electrochemical zero-mode waveguide (ZMW), a special hybrid nanophotonic/nanoelectronic architecture in which the lower ring electrode of an NEA nanopore functions both as a working electrode to initiate electron transfer reactions and as the optical cladding layer of a ZMW. Furthermore, while the work described here is largely exploratory and fundamental, we believe that the development of NEAs will enable important applications that emerge directly from the unique coupled transport and electron-transfer capabilities of NEAs, including in situ molecular separation and detection with external stimuli, redox-based electrochemical rectification in individually encapsulated nanopores, and coupled sorters and analyzers for nanoparticles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

EHR-BERT: A BERT-based model for effective anomaly detection in electronic health records

Objective: Physicians and clinicians rely on data contained in electronic health records (EHRs), as recorded by health information technology (HIT), to make informed decisions about their patients. The reliability of HIT systems in this regard is critical to patient safety. Consequently, better tools are needed to monitor the performance of HIT systems for potential hazards that could compromise the collected EHRs, which in turn could affect patient safety. In this paper, we propose a new framework for detecting anomalies in EHRs using sequence of clinical events. This new framework, EHR-Bidirectional Encoder Representations from Transformers (BERT), is motivated by the gaps in the existing deep-learning related methods, including high false negatives, sub-optimal accuracy, higher computational cost, and the risk of information loss. EHR-BERT is an innovative framework rooted in the BERT architecture, meticulously tailored to navigate the hurdles in the contemporary BERT method; thus, enhancing anomaly detection in EHRs for healthcare applications.Methods: The EHR-BERT framework was designed using the Sequential Masked Token Prediction (SMTP) method. This approach treats EHRs as natural language sentences and iteratively masks input tokens during both training and prediction stages. This method facilitates the learning of EHR sequence patterns in both directions for each event and identifies anomalies based on deviations from the normal execution models trained on EHR sequences.Results: Extensive experiments on large EHR datasets across various medical domains demonstrate that EHR-BERT markedly improves upon existing models. It significantly reduces the number of false positives and enhances the detection rate, thus bolstering the reliability of anomaly detection in electronic health records. This improvement is attributed to the model’s ability to minimize information loss and maximize data utilization effectively.Conclusion: EHR-BERT showcases immense potential in decreasing medical errors related to anomalous clinical events, positioning itself as an indispensable asset for enhancing patient safety and the overall standard of healthcare services. The framework effectively overcomes the drawbacks of earlier models, making it a promising solution for healthcare professionals to ensure the reliability and quality of health data.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Removal of Homogeneous Broadening from 1 H-Detected Multidimensional Solid-State NMR Spectra

1 H-detected magic-angle spinning (MAS) NMR experiments have revolutionized the NMR studies of biological and inorganic solids by providing unparalleled sensitivity and resolution. Despite these gains, homogeneous broadening, originating from the incomplete removal of homonuclear dipolar interactions under fast MAS, remains highly prevalent and limits the achievable resolution. In direct analogy to super-resolution microscopy methods, we show that resolution beyond that currently achievable by fast MAS alone can be obtained by experiment-driven deconvolution. Following the acquisition of a single 2D NMR spectrum to measure the frequency-dependent homogeneous lineshapes, any number of 1 H-detected spectra can be enhanced in resolution, yielding comparable spectra as obtained with twice the MAS frequency. In conclusion, the versatility of this approach is demonstrated in the enhancement of single- and double-quantum homonuclear correlation spectra, in addition to heteronuclear correlation spectra acquired on a surface organometallic complex and the protein GB1.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High Energy Micron Scale Pixel Hybrid Detector

The objective of this technology development project has been to fabricate and characterize a new X-ray area image sensor innovation designed for high efficiency detection and imaging of hard X-rays (>20 KeV) with micron scale pixel resolution. A key technology component consists of a monolithic hybrid X-ray detector built by layering an amorphous Selenium X-ray photoconductor film directly deposited on a small pitch (7.8μm) CMOS active pixel readout array. A specific goal of this work is to provide a new detector tool to researchers working with synchrotron light sources, to extend the depth of exploration into nanoscale structures, and do so cost effectively. Early generation X-ray imaging detector tools fail to provide adequate resolving power and efficiency at high energies and our innovation provides a solution. A majority of proposed phase I tasks were completed. Those tasks included, in collaboration with KA Imaging, successful fabrication of specified a-Se layers on a 1Mpixel CMOS readout array to create the direct hybrid X-ray imaging array, packaging of the imaging array, assembly of electronics into a shielded detector box, loading user interface software for camera control and image capture, and performing initial (no X-ray) detector evaluation at Farrier Microengineering facilities. After initial tests, extensive testing using the X-ray beam line 1-BM source at Argonne National Laboratory Advanced Photon Source(ANL-APS) was performed. Imaging performance studies were conducted at multiple X-ray beam energies. Studies included X-ray response vs. X-ray energy, vs. applied detector field strength (HV), response linearity vs. integration time, MTF vs. beam energy, image lag measurements, and micron scale resolution pattern target imaging. This high energy micron scale X-ray detection technology is a first of a kind to be evaluated at the ANL-APS and is supported by Dr. Antonino Miceli, head of the detector physics group. Accomplishments include the first successful demonstration of a 1Mpix amorphous Selenium on CMOS readout direct hybrid X-ray imaging detector at a DOE sponsored National Laboratory. Modeled performance predictions were confirmed, proving micron scale resolution as well as an order of magnitude increase in conversion efficiency over conventional scintillator detector performance. A discovery of evidence of propagation-based phase contrast edge enhancement was unplanned and will be exploited in future experiments. This phase 1 technology demonstration verifies the efficacy of proposed high energy micron scale pixel X-ray hybrid a-Se imaging array products. The new detector products will cost effectively replace early generation detector technologies that currently fail to address increasing demand for tools to study nano structures and physical processes at high X-ray energies above 20keV. For example, current systems for transmission X-ray microscopy have low efficiency and available large pixel (~55µm) direct detectors do not offer sufficient resolution for Bragg fringe imaging at high energies. This detector innovation will solve these inadequacies. The new detector technology will compete in a $50M scientific X-ray detector market, growing at 6%, and will benefit Microtomography(µCT), X-ray diffractometry (XRD), Coherent Diffraction Imaging (CDI) applications. One application specified by Dr. Miceli at ANL is the 3D reconstruction of compact crystals at high energies requires small pixel high efficiency X-ray detectors. Farrier Microengineering, working with colleagues at KA Imaging and the University of Waterloo, successfully achieved the critical objectives of the Phase I proposal. We have proven the technical feasibility of this innovation by building and successfully testing a 1Mpixel a-Se/CMOS hybrid direct X-ray imaging array. Our commercialization roadmap of detector products will be implemented during a phase II project. We will demonstrate a migration of the technology to larger detector array sizes, improved temporal performance with detector layer engineering, and improved environmental and operational stability. Manufacturability and cost effectiveness are key objectives and product designs will leverage current state of the art CMOS wafer fabrication quality and volume manufacturing economics.

36 MATERIALS SCIENCE↗

Non-Conductor-Contact Surface Wave Reflectometry for Cable Insulation Damage Detection

Here, this paper presents a non-conductor-contact surface wave-based reflectometry technique to detect and locate missing or damaged insulation and/or jacket of electrical cables. The described sensor may be uniquely and practically implemented on live cables as a non-destructive evaluation (NDE) method since it may be applied to the outer insulation/jacket of a cable and requires no direct contact to the conductor. The innovation lies in a high-frequency surface wave launcher that can introduce broadband signals in the GHz frequencies that insure maximum electromagnetic (EM) energy localization within the insulation and/or jacket material. By further processing the reflection data in the frequency domain, the location and severity of insulation damage is detected. Simulated results of thin, thick, short, and long cables show the results expected from small, medium, and large damage regions. For example, the detection of 40 mm-long damage region at 40 m distance on a 50 m long cable (2.44 cm diameter) is demonstrated. Experimental results are presented that validate simulation findings.

Non Destructive Evaluation↗

Residential HVAC Fault Data Collection Plan – Refrigerant Undercharge and Overcharge Faults

Heating, ventilation, and air-conditioning (HVAC) systems can develop faults due to poor installation practices or gradual wear and tear, leading to decreased HVAC system’s efficiency, compromised thermal comfort, and shortened equipment lifespan (EERE, 2018). Automated fault detection and diagnosis (AFDD) technologies offer a solution by identifying energy-wasting HVAC faults, such as inadequate indoor airflow and incorrect refrigerant charge, and guiding technicians to enhance system efficiency. In the realm of residential HVAC, AFDD can be implemented through various fault detection and diagnosis capabilities, sensor configurations, and target applications. These technologies typically fall into three categories: smart diagnostic tools, original equipment manufacturer (OEM)-embedded tools, and add-on tools. Smart diagnostic tools employ temporarily installed sensors to directly measure HVAC system characteristics, while OEM-embedded tools utilize factory-installed sensors to identify faults or assess system performance. However, both these types of AFDD technologies are often only accessible for high-end HVAC equipment or require additional sensor installation by qualified technicians, resulting in high investment costs and limited applicability for low-income residential buildings. On the other hand, add-on tools rely solely on data from smart thermostats and meters to detect faults by continuously analyzing equipment runtime or energy usage. As smart thermostat and meter costs decrease and their prevalence increases, these tools can be readily deployed in low-income residential buildings. However, they possess limited capabilities as they rely solely on basic trend analysis. Enhancing such tools with advanced machine learning algorithms can significantly improve their effectiveness.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Security proof of practical quantum key distribution with detection-efficiency mismatch

Quantum key distribution (QKD) protocols with threshold detectors are driving high-performance QKD demonstrations. The corresponding security proofs usually assume that all physical detectors have the same detection efficiency. However, the efficiencies of the detectors used in practice might show a mismatch depending on the manufacturing and setup of these detectors. A mismatch can also be induced as the different spatial-temporal modes of an incoming signal might couple differently to a detector. Here we develop a method that allows to provide security proofs without the usual assumption. Our method can take the detection-efficiency mismatch into account without having to restrict the attack strategy of the adversary. Especially, we do not rely on any photon-number cutoff of incoming signals such that our security proof is directly applicable to practical situations. We illustrate our method for a receiver that is designed for polarization encoding and is sensitive to a number of spatial-temporal modes. In our detector model, the absence of quantum interference between any pair of spatial-temporal modes is assumed. For a QKD protocol with this detector model, we can perform a security proof with characterized efficiency mismatch and without photon-number cutoff assumption. Our method also shows that in the absence of efficiency mismatch in our detector model, the key rate increases if the loss due to detection inefficiency is assumed to be outside of the adversary's control, as compared to the view where for a security proof this loss is attributed to the action of the adversary.

97 MATHEMATICS AND COMPUTING↗

Acoustic waves from the 2023 April 20 SpaceX Starship rocket explosion travelling in the elevated ‘AtmoSOFAR’ channel

SUMMARY The ability to detect low-frequency sounds from distant energetic events depends on the temperature and wind structure of the atmosphere. Thus, from time to time surface-based acoustic detectors may not be able to capture sounds arriving from certain directions. However, the temperature minimum at the tropopause may create an acoustic duct called the ‘AtmoSOFAR’ channel that could transmit acoustic waves laterally—but perhaps not to the ground. If true, then elevated sensors such as those borne aloft by balloons would record the signatures even in regions where ground-based sensors cannot. This has been difficult to prove because high altitude acoustic sources are rare and balloon deployments are sporadic. This work describes the detection and characterization of powerful acoustic waves generated during the launch and terminal explosion of the SpaceX Starship rocket on 2023 April 20 using a pair of microbarometers on a stratospheric balloon. The signals travelled through the AtmoSOFAR channel, carrying information about the size and nature of their source. This channel also appears to leak some acoustic energy to the ground, in agreement with previous studies. The acoustic yield of the Starship terminal explosion was on the order of $10^3$ tons trinitrotoluene equivalent, which agrees with the estimated fuel load of the vehicle to about a factor of 2, but is two orders of magnitude larger than optical estimates. These results support an earlier study that claimed lateral transmission of sound from a smaller rocket through the AtmoSOFAR channel. The transmission of source information through the AtmoSOFAR channel motivates its use for monitoring other natural and anthropogenic events using balloon-borne sensors. This may become increasingly important as more and more private and government entities conduct spacecraft launches and reentries. It may also provide a means of monitoring clear air turbulence and other sound-generating atmospheric phenomena at a distance.

58 GEOSCIENCES↗

Social Media Analytics Relevant to TikTok - a Literature Review and Directions for Future Research

We have attempted to capture a sense of the scientific state of the art in studying social media platforms, including data collection from platforms, understanding platform behavior, known adversarial uses, and adverse content detection, classification, and quantification. Our coverage of the field is backed up by roughly two hundred citations, and it concludes with a comparative analysis and a list of apparent gaps and potential paths forward.

99 GENERAL AND MISCELLANEOUS↗

Characterization of the biofilm landscape of Bacillus subtilis by spatial microproteomics

Bulk proteomics has been demonstrated to differentiate subpopulations within bacterial colonies, yet advanced analyses by mass spectrometry imaging (MSI) hold even greater promise for the future. This technology can enable high-throughput spatial phenotyping that can reshape biological discovery by providing visualization of components of various biomolecular mechanisms. With high mass resolving power and high spatial resolution analyses being routine, we can confidently enable intact protein imaging directly from samples with minimal preparation. Pairing those analyses with bulk experimental libraries can provide high confidence in annotations of post-translational modifications (PTMs) and truncations. Revealing PTM localization within the samples unlocks a direct window into unknown biology at the microscale. However, top-down proteomics (TDP) is not commonplace for microbial species, largely due to challenges in identifying detected peptides and proteins; considering the theoretical proteome of even the well-studied model bacterium Bacillus subtilis was only partially mapped recently. With little still known about the form and function of many of these proteins – let alone proteoforms, where PTMs and truncations of the same protein may possess unique physiological roles – there is a wealth of work to be done. Here we jointly apply TDP and MSI to describe the microscale spatial proteomic landscape within B. subtilis and further demonstrate the feasibility of detecting differentiated subpopulations through proteoforms across the biofilm landscape.

bacterial biofilms↗

Machine learning accelerated discrete element modeling of granular flows

Granular flows are widely encountered in many industrial processes and natural phenomena. Discrete Element Modeling (DEM) is a useful tool for understanding and troubleshooting devices, which handle granular materials. However, its applicability is significantly limited by the huge computational cost associated with detecting and computing collisions. In this research, the computation speed of DEM was accelerated by orders of magnitude using a convolutional neural network to replace the direct calculation of particle-particle and particle-boundary collisions. The MFiX software was used to generate the training and testing dataset. Additionally, a GPU accelerated TensorFlow model was used to train the neural network and test the results. The model fluctuations caused by different training steps were reduced with a multi-scale loss function. The accuracy was improved with more frames within one training step. The modeling of a rotating drum and a hopper demonstrated the accuracy and efficiency of this machine learning accelerated DEM in the simulation of granular flows.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗