Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Sixth NASA Glenn Research Center Propulsion Control and Diagnostics (PCD) Workshop

The Intelligent Control and Autonomy Branch at NASA Glenn Research Center hosted the Sixth Propulsion Control and Diagnostics Workshop on August 22-24, 2017. The objectives of this workshop were to disseminate information about research being performed in support of NASA Aeronautics programs; get feedback from peers on the research; and identify opportunities for collaboration. There were presentations and posters by NASA researchers, Department of Defense representatives, and engine manufacturers on aspects of turbine engine modeling, control, and diagnostics.

Collaboration↗

Rest-Frame UV and Optical Emission Line Diagnostics of Ionized Gas Properties: a Test Case in a Star-Forming Knot of a Lensed Galaxy at Z ∼ 1.7

We examine the diagnostic power of rest-frame ultraviolet (UV) nebular emission lines, and compare them to more commonly used rest-frame optical emission lines, using the test case of a single star-forming knot of the bright lensed galaxy RCSGA 032727–132609 at redshift z ∼ 1.7. This galaxy has complete coverage of all the major rest-frame UV and optical emission lines from Magellan/MagE and Keck/NIRSPEC. Using the full suite of diagnostic lines, we infer the physical properties: nebular electron temperature (T(sub e)), electron density (n(sub e)), oxygen abundance (log (O/H), ionization parameter [log (q), and interstellar medium (ISM) pressure (log (P/k)]. We examine the effectiveness of the different UV, optical, and joint UV–optical spectra in constraining the physical conditions. Using UV lines alone we can reliably estimate log (q), but the same is difficult for log (O/H). UV lines yield a higher (∼1.5 dex) log (P/k) than the optical lines, as the former probes a further inner nebular region than the latter. For this comparison, we extend the existing Bayesian inference code IZI, adding to it the capability to infer ISM pressure simultaneously with metallicity and ionization parameter. This work anticipates future rest-frame UV spectral data sets from the James Webb Space Telescope (JWST) at high redshift and from the Extremely Large Telescope (ELT) at moderate redshift.

Acharyya, Ayan↗

Arcjet Supplemental Diagnostics

This document proposes a new set of diagnostics designed to be implemented on the NASA Ames miniature Arcjet Research Chamber (mARC) for improved characterization of the flow. The diagnostics are grouped into three classes:higher cadence measurements, higher spatial resolution, and computer vision techniques for improved analysis of existing imaging. The goal is to better understand and quantify the following properties: flow statistics/uncertainty, temporal & spatial non-uniformity, flow temperature/enthalpy

Haw, Magnus A.↗

Educational and Scientific Applications of Climate Model Diagnostic Analyzer

Climate Model Diagnostic Analyzer (CMDA) is a web-based information system designed for the climate modeling and model analysis community to analyze climate data from models and observations. CMDA provides tools to diagnostically analyze climate data for model validation and improvement, and to systematically manage analysis provenance for sharing results with other investigators. CMDA utilizes cloud computing resources, multi-threading computing, machine-learning algorithms, web service technologies, and provenance-supporting technologies to address technical challenges that the Earth science modeling and model analysis community faces in evaluating and diagnosing climate models. As CMDA technology and infrastructure have matured, we have developed the educational and scientific applications of CMDA. Educationally, CMDA supported the summer school of the JPL Center for Climate Sciences in 2014, 2015, and 2016. In the summer school, the students work on group research projects where CMDA provide datasets, analysis tools, and provenance support utility tools. Each student is assigned to a virtual machine with CMDA installed in Amazon Web Services. Scientifically, we have developed several science use cases of CMDA covering various topics, datasets, and analysis types. Each of the science use cases is described in terms of a scientific goal, datasets used, the analysis tools used, scientific results discovered, an analysis result such as output plots and data files, and a link to the corresponding analysis service call with all the input arguments filled.

Bao, Qihao↗

Is [Y/Mg] a Reliable Age Diagnostic for FGK Stars?

Current spectroscopic surveys are producing large catalogs of chemical abundances for stars of all types. The yttrium-to-magnesium ratio, [Y/Mg], has emerged as a candidate age indicator for solar twins in the local stellar neighborhood. However, it is unclear whether it is a viable age diagnostic for more diverse stellar types, so we investigate [Y/Mg] as an age indicator for the FGK-type planet host stars observed by Kepler. We find that the [Y/Mg] "Clock" is most precise for solar twins, with a [Y/Mg]/age slope of m = −0.0370 ±0.0071 dex Gyr −1 and σ Age = 2.6 Gyr. We attribute the lower precision compared to literature results to nonsolar twins contaminating our solar twin sample and recommend a 1.5 Gyr systematic uncertainty for stellar ages derived with any [Y/Mg]–Age relation. We also analyzed the [Y/Mg] Clock as a function of T eff , log⁡ g, and metallicity individually and find no strong trends, but we compute statistically significant [Y/Mg]–Age relations for subsamples defined by ranges in T eff , log g, and metallicity. Finally, we compare [Y/Mg] and rotation ages and find statistically similar trends as for isochrone ages, although we find that rotation ages perform better for GK dwarfs while isochrones perform better for FG subgiants. We conclude that the [Y/Mg] Clock is most precise for solar twins and analogs but is also a useful age diagnostic for FGK stars.

Travis A. Berger↗

Development of Langmuir and Spatially Resolved OES Diagnostics for Arc Jet Shock and Boundary Layer Measurements Relevant to Atmospheric Re-Entry Environments

The second-generation miniature Arc Jet Research Chamber (mARC) ground testing facility at NASA Ames requires physical characterization of its supersonic plasma flow to verify numerical models and material sample testing. Two types of plasma diagnostics will be utilized: Langmuir probes and optical emission spectroscopy (OES). Several single and triple Langmuir probes have been constructed and will be inserted parallel to the flow via a sweep arm to measure post-shock electron temperature and number density along radial profiles at different axial distances. Due to the high heat flux (200-3000 W/cm2) sweep durations are necessarily short (< 0.1 s). Measuring these properties near the probe surface provide characterization of the post-shock environment. This is an important metric for validating coupled CFD-material codes, and will provide insight into longstanding thermocouple anomalies attributed to charging of heatshield surfaces. An OES system has also been assembled to obtain spatially resolved density and temperature for various flow species. The system consists of a convex lens that forms an image of the plasma onto a 16-channel linear fiber array, which will simultaneously capture the spectra from sixteen different locations. The light emission from the plasma is then focused by a spherical mirror into a spectrometer and recorded with a camera. These measurements non-intrusively provide a new spatially resolved flow characterization capability. This will initially be used to resolve issues with shock radiation interference in pyrometer measurements of material surface temperature. The design of each diagnostic and any initial results will be discussed.

Ethan Main-Loam Leong↗

The Case for Solar Full-disk Spectral Diagnostics: Chromosphere to Corona

In the context of the recent call for white papers for the Decadal Survey for Solar and Space Physics (Heliophysics) 2024–2033, we present the argument that spatially-resolved spectral diagnostics over the full solar disk should be made a high-priority goal in Heliophysics and lead to the development of a mission concept that has the potential to become a cornerstone of the Heliophysics System Observatory (HSO). We claim that a mission providing consistent full-disk sampling of plasma properties (Doppler-shifts, non-thermal velocities, electron densities, elemental composition, etc.) of the chromosphere-corona system at the dynamic timescales of solar eruptive phenomena will revolutionize the field by adding the spectral diagnostics capability to the highly successful concept of full-disk imaging, everywhere, all the time, represented by the Solar Dynamics Observatory (SDO). We argue for it to be developed by the end of the current Decadal Survey cycle around the lessons learned from spectroscopic missions in the current NASA development pipeline, that include innovative strategies for faster integration of large fields-of-view, and comprehensive temperature coverage.

Sun↗

Overview of Extractive and Optical PM Measurements from the NASA SE-5 High Pressure Flame Diagnostics Laboratory

Soot emissions measurements of multiphase non-premixed flames are sparse in the literature due to the complexities of sampling in such environments. We present an overview from on-going work at the NASA SE-5 High Pressure Flame Diagnostics laboratory focusing on soot and gaseous emissions at elevated pressures. SE-5 is a gaseous and liquid fueled high pressure flame tube facility capable of operating at pressures up to 880 psia, cooling capacity of 4,000,000 BTU/hr, liquid fuel flow rates up to 2 GPH, and an equivalence ratio range of 0.2 (fuel lean) to 4 (fuel rich). SE-5 provides optical access via four UV-grade fused silica optical windows of the primary reaction zone enabling non-intrusive optical diagnostics of the flame.

Soot↗

DESIGN OF VISIBLE DIAGNOSTIC BEAMLINE FOR NSLS2 STORAGE RING

A visible synchrotron light monitor (SLM) beam line has been designed at the NSLS2 storage ring, using the bending magnet radiation. A retractable thin absorber will be placed in front of the first mirror to block the central x-rays. The first mirror will reflect the visible light through a vacuum window. The light is guided by three 6-inch diameter mirrors into the experiment hutch. In this paper, we will describe design work on various optical components in the beamline. The ultra high brightness NSLS-II storage ring is under construction at Brookhaven National Laboratory. It will have 3GeV, 500mA electron beam circulating in the 792m ring, with very low emittance (0.9nm.rad horizontal and 8pm.rad vertical). The ring is composed of 30 DBA cells with 15 fold symmetry. Three damping wigglers will be installed in long straight sections 8, 18 and 28 to lower the emittance. While electrons pass through the bending magnet, synchrotron radiation will be generated covering a wide spectrum. There are other insertion devices in the storage ring which will generate shorter wavelength radiation as well. Synchrotron radiation has been widely used as diagnostic tool to measure the transverse and longitudinal profile. Three synchrotron light beam lines dedicated for diagnostics are under design and construction for the NSLS-II storage ring: two x-ray beam lines (pinhole and CRL) with the source points from Cell 22 BM{_}A (first bending in the DBA cell) and Cell22 three-pole wiggler; the third beam line is using visible part of radiation from Cell 30 BM{_}B (second bending magnet from the cell). Our paper focuses on the design of the visible beam line - SLM.

43 PARTICLE ACCELERATORS↗

New topics in coherent anti-stokes raman scattering gas-phase diagnostics : femtosecond rotational CARS and electric-field measurements.

We discuss two recent diagnostic-development efforts in our laboratory: femtosecond pure-rotational Coherent anti-Stokes Raman scattering (CARS) for thermometry and species detection in nitrogen and air, and nanosecond vibrational CARS measurements of electric fields in air. Transient pure-rotational fs-CARS data show the evolution of the rotational Raman polarization in nitrogen and air over the first 20 ps after impulsive pump/Stokes excitation. The Raman-resonant signal strength at long time delays is large, and we additionally observe large time separation between the fs-CARS signatures of nitrogen and oxygen, so that the pure-rotational approach to fs-CARS has promise for simultaneous species and temperature measurements with suppressed nonresonant background. Nanosecond vibrational CARS of nitrogen for electric-field measurements is also demonstrated. In the presence of an electric field, a dipole is induced in the otherwise nonpolar nitrogen molecule, which can be probed with the introduction of strong collinear pump and Stokes fields, resulting in CARS signal radiation in the infrared. The electric-field diagnostic is demonstrated in air, where the strength of the coherent infrared emission and sensitivity our field measurements is quantified, and the scaling of the infrared signal with field strength is verified.

99 GENERAL AND MISCELLANEOUS↗

Reduction of Systematic Errors in Diagnostic Receivers Through the Use of Balanced Dicke-Switching and Y-Factor Noise Calibrations

Receivers designed for diagnostic applications range from those having moderate sensitivity to those possessing large dynamic range. Digital receivers have a dynamic range which are a function of the number of bits represented by the ADC and subsequent processing. If some of this range is sacrificed for extreme sensitivity, noise power can then be used to perform two-point load calibrations. Since load temperatures can be precisely determined, the receiver can be quickly and accurately characterized; minute changes in system gain can then be detected, and systematic errors corrected. In addition, using receiver pairs in a balanced approach to measuring X+, X-, Y+, Y-, reduces systematic offset errors from non-identical system gains, and changes in system performance. This paper describes and demonstrates a balanced BPM-style diagnostic receiver, employing Dicke-switching to establish and maintain real-time system calibration. Benefits of such a receiver include wide bandwidth, solid absolute accuracy, improved position accuracy, and phase-sensitive measurements. System description, static and dynamic modelling, and measurement data are presented.

99 GENERAL AND MISCELLANEOUS↗

Ultra-Short Electron Bunch and X-Ray Temporal Diagnostics with an X-Band Transverse Deflector

The measurement of ultra-short electron bunches on the femtosecond time scale constitutes a very challenging problem. In X-ray free-electron laser facilities such as the Linac Coherent Light Source (LCLS), generation of sub-ten femtosecond X-ray pulses is possible, and some efforts have been put into both ultra-short electron and X-ray beam diagnostics. Here we propose a single-shot method using a transverse rf deflector (X-band) after the undulator to reconstruct both the electron bunch and X-ray temporal profiles. Simulation studies show that about 1 fs (rms) time resolution may be achievable in the LCLS and is applicable to a wide range of FEL wavelengths and pulse lengths. The jitter, resolution and other related issues will be discussed. The successful operation of the Linac Coherent Light Source (LCLS), with its capability of generating free-electron laser (FEL) X-ray pulses from a few femtoseconds (fs) up to a few hundred fs, opens up vast opportunities for studying atoms and molecules on this unprecedented ultrashort time scale. However, tremendous challenges remain in the measurement and control of these ultrashort pulses with femtosecond precision, for both the electron beam (e-beam) and the X-ray pulses. For ultrashort e-beam bunch length measurements, a standard method has been established at LCLS using an S-band radio-frequency (rf) deflector, which works like a streak camera for electrons and is capable of resolving bunch lengths as short as {approx} 10 fs rms. However, the e-beam with low charges of 20 pC at LCLS, which is expected to be less than 10 fs in duration, is too short to be measured using this transverse deflector. The measurement of the electron bunch length is helpful in estimating the FEL X-ray pulse duration. However, for a realistic beam, such as that with a Gaussian shape or even a spiky profile, the FEL amplification varies along the bunch due to peak current or emittance variation. This will cause differences between the temporal shape or duration of the electron bunch and the X-ray pulse. Initial experiments at LCLS have revealed that characterization of the X-ray pulse duration on a shot-by-shot basis is critical for the interpretation of the data. However, a reliable x-ray pulse temporal diagnostic tool is not available so far at the LCLS. We propose a novel method in this paper to characterize the FEL X-ray pulse duration and shape. A transverse rf deflector is used in conjunction with an e-beam energy spectrometer, located after the FEL undulator. By measuring the difference in the e-beam longitudinal phase space between FEL-on and FEL-off, we can obtain the time-resolved energy loss and energy spread induced from the FEL radiation, allowing the FEL X-ray temporal shape to be reconstructed.

43 PARTICLE ACCELERATORS↗

The EMMA Accelerator, a Diagnostic Systems Overview

The 'EMMA' Non-Scaling Fixed Field Alternating Gradient (ns-FFAG) international project is currently being commissioned at Daresbury Laboratory, UK. This accelerator has been equipped with a number of diagnostic systems to facilitate this. These systems include a novel time-domain-multiplexing BPM system, moveable screen systems, a time-of-flight instrument, Faraday cups, and injection/extraction tomography sections to analyze the single bunch beams. An upgrade still to implement includes the installation of wall current monitors. This paper gives an overview of these systems and shows some data and results from the diagnostics that have contributed to the successful demonstration of a serpentine acceleration by this novel accelerator.

43 PARTICLE ACCELERATORS↗

Ultrasensitive microanalytical diagnostic methods for rickettsial pathogens

A strategic CRADA was established between Sandia National Laboratories (SNL) and the University of Texas Medical Branch (UTMB) at Galveston to address pressing needs for US protection against biological weapons of mass destruction (WMD) and emerging infectious diseases. The combination of unique expertise and facilities at UTMB and SNL enabled interdisciplinary research efforts in the development of rapid and accurate diagnostic methods for early detection of trace priority pathogen levels. Outstanding postdoctoral students were also trained at both institutions to help enable the next generation of scientists to tackle the challenging interdisciplinary problems in the area of biodefense and emerging infectious diseases. Novel approaches to diagnostics were developed and the both the speed of assays as well as the detection sensitivity were improved by over an order of magnitude compared to traditional methods. This is a significant step toward more timely and specific detection of dangerous infections. We developed in situ polymerized porous polymer monoliths that can be used as (1) size exclusion elements for capture and processing of rickettsial infected cells from a sample, (2) photopatternable framework for grafting high densities of functionalized antibodies/fluorescent particles using novel monolith chemistry. Grafting affinity reagents specific to rickettsial particles enables rapid, ultra-sensitive assays by overcoming transport limitations of traditional planar assay approaches. We have selectively trapped particles and bacteria at the cell trap and have also detected picomolar mouse IL-6 captured with only 20 minutes total incubation times using the densely patterned monolith framework. As predicted, the monolith exhibits >10x improvements in both capture speed and capture density compared to traditional planar approaches. The most significant advancements as part of this CRADA is the optimization of techniques allowing the detection of <10 rickettsial cells in a whole blood sample. This detection limit is over 2 orders of magnitude more sensitive that previously reported methods and overcomes a key hurdle in ability to sense dangerous infections before they are too late to treat and contain. We also showed that in the new format, cross-reactivity with interfering species is reduced thereby increasing the specificity of such tests. Promising options to treat whole blood and avoid clogging and non-specific fouling of sensors were also developed.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Fermilab PXIE Beam Diagnostics Development and Testing at the HINS Beam Facility

Fermilab is planning the construction of a prototype front end of the Project X linac. The Project X Injector Experiment (PXIE) is expected to accelerate 1 mA CW H- beam up to 30 MeV. Some of the major goals of the project are to test a CW RFQ and H- source, a broadband bunch-by-bunch beam chopper and a low-energy superconducting linac. The successful characterization and operation of such an accelerator place stringent requirements on beamline diagnostics. These crucial beam measurements include bunch currents, beam orbit, beam phase, bunch length, transverse profile and emittance and beam halo and tails, as well as the extinction performance of the broadband chopper. This paper presents PXIE beam measurement requirements and instrumentation development plans. Presented are plans to test key instruments at the Fermilab High Intensity Neutrino Source (HINS) beam facility. Since HINS is already an operational accelerator, utilizing HINS for instrumentation testing will allow for quicker development of the required PXIE diagnostics.

43 PARTICLE ACCELERATORS↗

Electron Beam Diagnostics Of The JLAB UV FEL

In this contribution we describe various systems and aspects of the electron beam diagnostics of the JLab UV FEL. The FEL is installed on a new bypass beam line at the existing 10 kW IR Upgrade FEL. Here, we describe a set of the following systems. A combination of OTR and phosphor viewers is used for measurements of the transverse beam profile, transverse emittance, and Twiss parameters. This system is also used for alignment of the optical cavity of the UV oscillator and to ensure the overlap between the electron beam and optical mode in the FEL wiggler. A system of beam position monitors equipped with log-amp based BPM electronics. Bunch length on the order of 120 fs RMS is measured with the help of a modified Martin-Puplett interferometer. The longitudinal transfer function measurement system is used to set up bunch compression in an optimal way, such that the LINAC RF curvature is compensated using only higher order magnetic elements of the beam transport. This set of diagnostic systems made a significant contribution in achieving first lasing of the FEL after only about 60 hours of beam operation.

43 PARTICLE ACCELERATORS↗

X-Ray Line-Shape Diagnostics and Novel Stigmatic Imaging Schemes For the National Ignition Facility

In response to a recent solicitation from the US Department of Energy we proposed the development of a new x-ray line-shape diagnostic and novel stigmatic imaging schemes for the National Ignition Facility (NIF). These diagnostics are based on the imaging properties of spherically bent crystals, explained in Fig. 1, which have already been successfully applied to the diagnosis of extended tokamak plasmas for measurements of the ion-temperature and toroidal flow-velocity profiles [United States Patent: US 6, 259, 763 B1] and refs. [1, 2].

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Automated diagnostic kiosk for diagnosing diseases

An automated and autonomous diagnostic apparatus that is capable of dispensing collection vials and collections kits to users interesting in collecting a biological sample and submitting their collected sample contained within a collection vial into the apparatus for automated diagnostic services. The user communicates with the apparatus through a touch-screen monitor. A user is able to enter personnel information into the apparatus including medical history, insurance information, co-payment, and answer a series of questions regarding their illness, which is used to determine the assay most likely to yield a positive result. Remotely-located physicians can communicate with users of the apparatus using video tele-medicine and request specific assays to be performed. The apparatus archives submitted samples for additional testing. Users may receive their assay results electronically. Users may allow the uploading of their diagnoses into a central databank for disease surveillance purposes.

60 APPLIED LIFE SCIENCES↗