Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detector Response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Optoacoustic detection using Stark modulation

Stark modulation of the absorbed laser radiation in an optoacoustic detector (or spectrophone) is reported. Measurements were made over a range of total pressure between 760 Torr and 50 Torr. Greatly enhanced molecular discrimination is suggested due to the tuning ability of the Stark-shifted absorption. The background signal obtained by operating in this mode is more than 500 times smaller than that obtained by operating the same optoacoustic detector in the conventional chopped radiation mode. The responsivity of the optoacoustic detector and the absorption coefficient of C2H4 are presented as a function of total pressure.

Kavaya, M. J.↗

Stressed photoconductive detector for far-infrared space applications

An optimized leaf-spring apparatus for applying uniaxial stress to a Ge:Ga far-IR photoconductor has been designed and tested. This design has significant advantages for space applications which require high quantum efficiency and stable operation over long periods of time. The important features include adequate spring deflection with relatively small overall size, torque-free stress, easy measurement of applied stress, and a detector configuration with high responsivity. One-dimensional arrays of stressed photoconductors can be constructed using this design. A peak responsivity of 38 A/W is achieved in a detector with a cutoff wavelength of 200 microns, which was operated at a temperature of 2.0 K and a bias voltage equal to one-half of the breakdown voltage.

Wang, J.-Q.↗

Neutron fluences and dose equivalents measured with passive detectors on LDEF

Neutron fluences were measured on LDEF in the low energy (< 1 MeV) and high energy (> 1 MeV) ranges. The low energy detectors used the 6Li(n,alpha)T reaction with Gd foil absorbers to separate thermal (< 0.2 eV) and resonance (0.2 eV-1 MeV) neutron response. High energy detectors contained sets of fission foils (181Ta, 209Bi, 232Th, 238U) with different neutron energy thresholds. The measured neutron fluences together with predicted spectral shapes were used to estimate neutron dose equivalents. The detectors were located in the A0015 and P0006 experiments at the west and Earth sides of LDEF under shielding varying from 1 to 19 g/cm2. Dose equivalent rates varied from 0.8 to 3.3 microSv/d for the low energy neutrons and from 160 to 390 microSv/d for the high energy neutrons. This compares with TLD measured absorbed dose rates in the range of 1000-3000 microGy/d near these locations and demonstrates that high energy neutrons contribute a significant fraction of the total dose equivalent in LEO. Comparisons between measurements and calculations were made for high energy neutrons based on fission fragment tracks generated by fission foils at different shielding depths. A simple 1-D slab geometry was used in the calculations. Agreement between measurements and calculations depended on both shielding depth and threshold energy of the fission foils. Differences increased as both shielding and threshold energy increased. The modeled proton/neutron spectra appeared deficient at high energies. A 3-D model of the experiments is needed to help resolve the differences.

LDEF Project↗

Octavius 4D characterization for flattened and flattening filter free rotational deliveries

Purpose: In this study the Octavius detector 729 ionization chamber (IC) array with the Octavius 4D phantom was characterized for flattening filter (FF) and flattening filter free (FFF) static and rotational beams. The device was assessed for verification with FF and FFF RapidArc treatment plans.Methods: The response of the detectors to field size, dose linearity, and dose rate were assessed for 6 MV FF beams and also 6 and 10 MV FFF beams. Dosimetric and mechanical accuracy of the detector array within the Octavius 4D rotational phantom was evaluated against measurements made using semiflex and pinpoint ionization chambers, and radiochromic film. Verification FF and FFF RapidArc plans were assessed using a gamma function with 3%/3 mm tolerances and 2%/2 mm tolerances and further analysis of these plans was undertaken using film and a second detector array with higher spatial resolution.Results: A warm-up dose of >6 Gy was required for detector stability. Dose-rate measurements were stable across a range from 0.26 to 15 Gy/min and dose response was linear, although the device overestimated small doses compared with pinpoint ionization chamber measurements. Output factors agreed with ionization chamber measurements to within 0.6% for square fields of side between 3 and 25 cm and within 1.2% for 2 × 2 cm{sup 2} fields. The Octavius 4D phantom was found to be consistent with measurements made with radiochromic film, where the gantry angle was found to be within 0.4° of that expected during rotational deliveries. RapidArc FF and FFF beams were found to have an accuracy of >97.9% and >90% of pixels passing 3%/3 mm and 2%/2 mm, respectively. Detector spatial resolution was observed to be a factor in determining the accurate delivery of each plan, particularly at steep dose gradients. This was confirmed using data from a second detector array with higher spatial resolution and with radiochromic film.Conclusions: The Octavius 4D phantom with associated Octavius detector 729 ionization chamber array is a dosimetrically and mechanically stable device for pretreatment verification of FF and FFF RapidArc treatments. Further improvements may be possible through use of a detector array with higher spatial resolution (detector size and/or detector spacing)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Response function and optimum configuration of semiconductor backscattered-electron detectors for scanning electron microscopes

A new highly efficient design for semiconductor detectors of intermediate-energy electrons (1-50 keV) for application in scanning electron microscopes is proposed. Calculations of the response function of advanced detectors and control experiments show that the efficiency of the developed devices increases on average twofold, which is a significant positive factor in the operation of modern electron microscopes in the mode of low currents and at low primary electron energies.

36 MATERIALS SCIENCE↗

Characterization of the Thermal Properties of Ir/Pt Bilayer Transition Edge Sensors

In this work, we are developing a low-T c TES-based large-area and low-threshold detector targeting a variety of potential applications. The detector consists of a 50.8-mm-diameter Si wafer as the substrate and radiation absorber, a single Ir/Pt bilayer TES sensor in the center, and normal metal Au pads added to the TES to strengthen the TES–absorber thermal coupling. Tight TES–absorber thermal coupling improves detector sensitivity and response uniformity. Here, we report on the electron–phonon (e–ph) coupling strengths for the Ir/Pt bilayer and Au that are measured with our prototype detectors and TES devices. We found that a second weak thermal link besides the one due to e–ph coupling in Ir/Pt or Au was required to explain our data. With the effects of the second weak link accounted for, the extracted e–ph coupling constant Σ for Ir/Pt bilayer in the T c range between 32 and 70 mK is 1.9×10 8 WK -5 m -3 , and Σ’s for Au at 40 mK and 55 mK are 2.2×10 9 WK -5 m -3 and 3.2×10 9 WK -5 m -3 , respectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of absorber coupled TES polarimeter at millimeter wavelengths.

We report an absorber coupled TES bolometric polarimeter, consisting of an absorptive metal grid and a Mo/Au bi-layer TES on a suspended silicon nitride membrane disk. The electromagnetic design of the polarization sensitive absorbers, the heat transport modeling of the detector, the thermal response of the TES, and the micro-fabrication processes are presented. We also report the results of laboratory tests of a single pixel prototype detector, and compare with theoretical expectations.

47 OTHER INSTRUMENTATION↗

Development of a Transition Edge Sensor Gamma Ray Microcalorimeter with an Epoxy Coupled Bulk Lead Absorber

Transition edge sensor (TES)-based gamma ray detectors have been developed primarily for use up to energies of {approx}100 keV. However, there are many interesting applications at higher energies. We have started to develop a TES gamma-ray detector to apply to Positron Annihilation Spectroscopy analysis at 511 keV. Our detector is composed of a bulk lead absorber, which is coupled to a thin-film TES using a small amount of epoxy. The response of our first detector showed a very long decay tail of {approx}135 ms. To improve the device response time we have designed a new detector in which the response time is improved by a factor of five.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Excitable systems as robust event trigger generators in noisy detectors

We study the response of a stochastic FitzHugh-Nagumo model to weak external forcing with the aim of implementing a nonlinear algorithm, devised for the robust detection of transient signals such as gravitational wave bursts. In order to test the performance of the algorithm, we exploited the ensemble of maximum entropy signals--known as chirplets. In particular, we investigated the chirplet parameter subspace representing the gravitational wave bursts within range of nowadays interferometric detectors. We found that the false alarm rate can be controlled by changing the constant term in the equation of the slow variable while the detection efficiency is completely insensitive to the kind of injected chirplet. The receiver operating characteristic curves have been evaluated and compared with the performance of power detectors (threshold crossing of local power), which are commonly used for the burst detection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Conceptual design of a hybrid Ge:Ga detector array

For potential applications in space infrared astronomy missions such as the Space Infrared Telescope Facility and the Large Deployable Reflector, integrated arrays of long-wavelength detectors are desired. The results of a feasibility study which developed a design for applying integrated array techniques to a long-wavelength (gallium-doped germanium) material to achieve spectral coverage between 30 and 200 microns are presented. An approach which builds up a two-dimensional array by stacking linear detector modules is presented. The spectral response of the Ge:Ga detectors is extended to 200 microns by application of uniaxial stress to the stack of modules. The detectors are assembled with 1 mm spacing between the elements. Multiplexed readout of each module is accomplished with integration sampling of a metal-oxide-semiconductor (MOS) switch chip. Aspects of the overall design, including the anticipated level of particle effects on the array in the space environment, a transparent electrode design for 200 microns response, estimates of optical crosstalk, and mechanical stress design calculations are included.

Parry, C. M.↗

Performance of an RPM based on Gd-lined plastic scintillator for neutron and gamma detection [ANIMMA--2015-IO-372]

A Radiation Portal Monitor (RPM) was developed by the Istituto Nazionale di Fisica Nucleare (INFN) and Ansaldo Nucleare (ANN) within the FP7 SCINTILLA European project. The system was designed to detect both gamma and neutron radiation with a single technology. It is conceived to monitor vehicle and cargo containers in transits across borders or ports, to find radioactive elements and to avoid illegal trafficking of strategic nuclear materials. The system is based on a {sup 3}He-free neutron detection technology using plastic scintillators coupled to Gadolinium to detect and discriminate gamma from neutron signals. During the 3 years of the SCINTILLA project the construction and test of the first two prototypes drove the definition of the final layout of a full RPM system consisting of two twin pillars as a portal for vehicle and cargo container scan. A custom System Control Software (SCS) manages the electronics of the RPM, the ancillary devices and the data analysis. The combination of the detector layout and of the software functionalities enables both to distinguish neutrons and gammas and to identify the energy range of a detected gamma source. The system was initially characterized via static tests with gamma and neutron sources in the INFN laboratory. These measurements were used to calibrate the detector, evaluate the response of the single pillars as well as of the full system, and optimize the RPM configuration and discrimination algorithm. During this phase, specific tests were performed to study the stability over time of the system, monitoring the measured the neutron and gamma count rates over periods of several weeks. The results allow us to demonstrate the reliability and robustness of the RPM. In a second time the RPM performance was studied via dynamic tests performed during the SCINTILLA test and benchmark campaigns. These measurements took place in the JRC ITRAP+10 facility at Ispra (Varese-Italy). The laboratory is equipped with an experimental set-up for dynamic tests of multiple systems according to international standards. The performed measurements utilized radioactive sources with activities selected according to ANSI and IEC standards to test the detector alarm performances in terms of gamma and neutron response, sensitivity to high gamma fields, sensitivity to moderated neutron sources as well as false alarm rates (FAR). In addition, the RPM was tested in challenging configurations exceeding the requirements set by international standards to determine the real limits of the system. The results obtained during these campaigns demonstrated that the system detection efficiency is not only compliant to international standards for its category, but often exceeds them, demonstrating the validity of the chosen technology and of the implemented layout. The positive performance also showed the effectiveness of the SCS and of its functionalities. To further demonstrate the system capabilities, a test in a real-life environment of the RPM is planned to happen in a near future by installing the detectors in a seaport. In this presentation I will give an overview of the RPM characteristics, of its performances as determined in the test campaign mentioned above and of future plans, to demonstrate how this technology can be an effective choice for the realization of {sup 3}He-free RPM detectors. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Research and Development Studies for Reactor Neutrino Experiments in Turkey (RNET)

The program of the Reactor Neutrino Experiments of Turkey includes a small portable Water-based liquid scintillator detector to detect neutrinos from the Akkuyu nuclear power plant, planned to begin operating in 2023. The small near-field detector will weigh about 2-3 tons and will be placed less than 100 meters from the reactor cores. The Reactor Neutrino Experiments of Turkey program also includes a medium-size 30-ton Water-based liquid scintillator detector, which will be placed 1-2 km away from the reactor cores and will be used as a far detector. Both detectors and their responses to neutrino interactions were simulated using a GEANT4-based RAT-PAC simulation package. Here, we will share the technical and physical details of both detectors, and discuss the ongoing R&D effort for neutrino studies in Turkey.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Near-infrared linear array spectrometer for space applications

A 128-element InSb linear detector array read out with a field effect transistor (FET) multiplexing scheme has been developed at the Jet Propulsion Laboratory. State-of-the-art NEP, uniform response, on-detector charge integration, and very low focal plane heat load compared to that of discrete detector arrays allows this type of array to open new possibilities for spaceborne near-infrared imaging spectrometers. Large number of cooled detector elements are feasible with the new technology, making it practical to design sensitive spectrometers even for spinning spacecraft where simultaneous wavelength coverage is necessary to avoid confusion of spatial with spectral variations.

Apt, J.↗

Investigation of Dalton and Amagat’s laws for gas mixtures with shock propagation

Dalton's and Amagat's laws (also known as the law of partial pressures and the law of partial volumes respectively) are two well-known thermodynamic models describing gas mixtures. We focus our current research on determining the suitability of these models in predicting effects of shock propagation through gas mixtures. Experiments are conducted at the Shock Tube Facility at the University of New Mexico (UNM). The gas mixture used in these experiments consists of approximately 50% sulfur hexafluoride (SF6) and 50% helium (He) by mass. Fast response pressure transducers are used to obtain pressure readings both before and after the shock wave; these data are then used to determine the velocity of the shock wave. Temperature readings are obtained using an ultra-fast mercury cadmium telluride (MCT) infrared (IR) detector, with a response time on the order of nanoseconds. Coupled with a stabilized broadband infrared light source (operating at 1500 K), the detector provides pre- and post-shock line-of-sight readings of average temperature within the shock tube, which are used to determine the speed of sound in the gas mixture. Paired with the velocity of the shock wave, this information allows us to determine the Mach number. Our experimental results are compared with theoretical predictions of Dalton's and Amagat's laws to determine which one is more suitable.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Wavelength Shifting in InP based Ultra-thin Quantum Well Infrared Photodetectors

We have demonstrated red-shifting of the wavelength response of a bound-to-continuum p-type ultra-thin InGaAs/Inp quantum well infrared photodetector after growth via rapid thermal annealing. Compared to the as-grown detector, the peak spectral response of the annealed detector was shifted to longer wavelength without any major degradation in responsivity characteristics.

Photodetector Thermal Annealing↗

IR detectors based on n-i-p-i superlattices

The principles of operation of n-i-p-i photodetectors are discussed. Special consideration is given to issues that are relevant to the performance of IR detectors such as noise, dark current, and surface effects. In addition, a novel IR detector that promises to provide information about the spectral distribution of the infrared radiation emitted from an object and, consequently, about its temperature, independent of the distance between detector and object is discussed. This detector makes use of the possibility to modulate the internal electric fields of an n-i-p-i superlattice with an applied voltage. By this technique the spectral responsivity of the detector may be controlled electrically and some information about the shape of the emission spectrum may be obtained.

Ruden, P. Paul↗

High availability through full redundancy of the CMS detector controls system

The CMS detector control system (DCS) is responsible for controlling and monitoring the detector status and for the operation of all CMS sub detectors and infrastructure. This is required to ensure safe and efficient data taking so that high quality physics data can be recorded. The current system architecture is composed of more than 100 servers in order to provide the required processing resources. An optimization of the system software and hardware architecture is under development to ensure redundancy of all the controlled subsystems and to reduce any downtime due to hardware or software failures. The new optimized structure is based mainly on powerful and highly reliable blade servers and makes use of a fully redundant approach, guaranteeing high availability and reliability. The analysis of the requirements, the challenges, the improvements and the optimized system architecture as well as its specific hardware and software solutions are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photon statistics in the macroscopic realm measured without photon counters

In a macroscopic realm, in which photons are too many to be counted by any photon-counting detector, photon statistics can be measured by using detectors simply endowed with linear response. We insert one of such detectors in a conventional photon-counting apparatus, which returns a voltage every time the detector responds to light by generating a number of elementary charges via its primary photodetection process. We only assume that, when a single charge is photogenerated, the probability density of the voltages is a distribution that is narrow with respect to its mean value. Under this hypothesis the output voltages can be suitably binned so that their probability distribution is the same as that of the photogenerated charges, that is, of the detected photons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗