Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detection.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Cyber-Attack Detection for Photovoltaic Farms Based on Power-Electronics-Enabled Harmonic State Space Modeling

Here in this paper, a physics-data-based detection method is proposed to detect a variety of cyber-attacks in Photovoltaic (PV) farms using the power electronics-enabled harmonic state space (HSS) models, which, to our knowledge, is original. At the device level, HSS-based detection is developed to monitor harmonic vectors of individual PV converter with minimum sensor measurements, thus improving accuracy and robustness compared to Kalman Filter-based detection. At the system level that involves multiple PV converters, a clustering approach is developed to investigate attack propagation and accurately locate attack sources within a PV farm. The proposed approach is one of the first attempts to address PV security through interaction between the device and system, maximizing the accuracy and robustness at different levels. To verify the feasibility, a comprehensive attacks model is built, including single attack, coordinated attacks, and replay attacks. Besides, the impacts of irradiance changes are taken into consideration in the test scenarios. With the real-time data acquisition and hardware-in-the-loop testbed, comprehensive test results are provided to verify the feasibility of the proposed detection methodology.

42 ENGINEERING↗

Microaneurysms detection with the radon cliff operator in retinal fundus images

Diabetic Retinopathy (DR) is one of the leading causes of blindness in the industrialized world. Early detection is the key in providing effective treatment. However, the current number of trained eye care specialists is inadequate to screen the increasing number of diabetic patients. In recent years, automated and semi-automated systems to detect DR with color fundus images have been developed with encouraging, but not fully satisfactory results. In this study we present the initial results of a new technique for the detection and localization of microaneurysms, an early sign of DR. The algorithm is based on three steps: candidates selection, the actual microaneurysms detection and a final probability evaluation. We introduce the new Radon Cliff operator which is our main contribution to the field. Making use of the Radon transform, the operator is able to detect single noisy Gaussian-like circular structures regardless of their size or strength. The advantages over existing microaneurysms detectors are manifold: the size of the lesions can be unknown, it automatically distinguishes lesions from the vasculature and it provides a fair approach to microaneurysm localization even without post-processing the candidates with machine learning techniques, facilitating the training phase. The algorithm is evaluated on a publicly available dataset from the Retinopathy Online Challenge.

60 APPLIED LIFE SCIENCES↗

Zone-based analysis for automated detection of abnormalities in chest radiographs

Purpose: The aim of this study was to develop an automated method for detection of local texture-based and density-based abnormalities in chest radiographs. Methods: The method was based on profile analysis to detect abnormalities in chest radiographs. In the method, one density-based feature, Density Symmetry Index, and two texture-based features, Roughness Maximum Index and Roughness Symmetry Index, were used to detect abnormalities in the lung fields. In each chest radiograph, the lung fields were divided into four zones initially and then the method was applied to each zone separately. For each zone, Density Symmetry Index was obtained from the projection profile of each zone, and Roughness Maximum Index and Roughness Symmetry Index were obtained by measuring the roughness of the horizontal profiles via moving average technique. Linear discriminant analysis was used to classify normal and abnormal cases based on the three indices. The discriminant performance of the method was evaluated using ROC analysis. Results: The method was evaluated on a database of 250 normal and 250 abnormal chest images. In the optimized conditions, the zone-based performance Az of the method for zones 1, 2, 3, and 4 were 0.917, 0.897, 0.892, and 0.814, respectively, and the case-based performance Az of the method was 0.842. Our previous method for detection of gross abnormalities was also evaluated on the same database. The case-based performance of our previous method was 0.689. Conclusions: In comparing the previous method and the new method proposed in this study, there was a great improvement by the new method for detection of local texture-based and density-based abnormalities. The new method combined with the previous one has potential for screening abnormalities in chest radiographs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A novel computer-aided lung nodule detection system for CT images

Purpose: The paper presents a complete computer-aided detection (CAD) system for the detection of lung nodules in computed tomography images. A new mixed feature selection and classification methodology is applied for the first time on a difficult medical image analysis problem. Methods: The CAD system was trained and tested on images from the publicly available Lung Image Database Consortium (LIDC) on the National Cancer Institute website. The detection stage of the system consists of a nodule segmentation method based on nodule and vessel enhancement filters and a computed divergence feature to locate the centers of the nodule clusters. In the subsequent classification stage, invariant features, defined on a gauge coordinates system, are used to differentiate between real nodules and some forms of blood vessels that are easily generating false positive detections. The performance of the novel feature-selective classifier based on genetic algorithms and artificial neural networks (ANNs) is compared with that of two other established classifiers, namely, support vector machines (SVMs) and fixed-topology neural networks. A set of 235 randomly selected cases from the LIDC database was used to train the CAD system. The system has been tested on 125 independent cases from the LIDC database. Results: The overall performance of the fixed-topology ANN classifier slightly exceeds that of the other classifiers, provided the number of internal ANN nodes is chosen well. Making educated guesses about the number of internal ANN nodes is not needed in the new feature-selective classifier, and therefore this classifier remains interesting due to its flexibility and adaptability to the complexity of the classification problem to be solved. Our fixed-topology ANN classifier with 11 hidden nodes reaches a detection sensitivity of 87.5% with an average of four false positives per scan, for nodules with diameter greater than or equal to 3 mm. Analysis of the false positive items reveals that a considerable proportion (18%) of them are smaller nodules, less than 3 mm in diameter. Conclusions: A complete CAD system incorporating novel features is presented, and its performance with three separate classifiers is compared and analyzed. The overall performance of our CAD system equipped with any of the three classifiers is well with respect to other methods described in literature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Position detection accuracy of a novel linac-mounted intrafractional x-ray imaging system

Purpose: The authors have developed a system that monitors intrafractional target motion perpendicular to the treatment beam with the aid of radioopaque markers by means of separating kV image and megavoltage (MV) treatment field on a single flat-panel detector. Methods: They equipped a research Siemens Artiste linear accelerator (linac) with a 41 x 41 cm{sup 2} a-Si flat-panel detector underneath the treatment head. The in-line geometry allows kV (imaging) and MV (treatment) beams to share closely aligned beam axes. The kV source, usually mounted directly across from the flat-panel imager, was retracted toward the gantry by 13 cm to intentionally misalign kV and MV beams, resulting in a geometric separation of MV treatment field and kV image on the detector. Two consecutive images acquired within 140 ms (the first with MV-only and the second with kV and MV signal) were subtracted to generate a kV-only image. The images were then analyzed ''online'' with an automated threshold-based marker detection algorithm. They employed a 3D and a 4D phantom equipped with either a single radioopaque marker or three Calypso beacons to mimic respiratory motion. Measured room positions were either cross-referenced with a phantom voltage signal (single marker) or the Calypso system. The accuracy of the back-projection (from detected marker positions into room coordinates) was verified by a simulation study. Results: A phantom study has demonstrated that the imaging framework is capable of automatically detecting marker positions and sending this information to the tracking tool at an update rate of 7.14 Hz. The system latency is 86.9 {+-} 1.0 ms for single marker detection in the absence of MV radiation. In the presence of a circular MV field of 5 cm diameter, the latency is 87.1 {+-} 0.9 ms. The total RMS position detection accuracy is 0.20 mm (without MV radiation) and 0.23 mm (with MV). Conclusions: Based on the evaluated motion patterns and MV field size, the positional accuracy and system latency indicate that this system is suitable for real-time adaptive applications.

60 APPLIED LIFE SCIENCES↗

A computerized scheme for lung nodule detection in multiprojection chest radiography

Purpose: Our previous study indicated that multiprojection chest radiography could significantly improve radiologists' performance for lung nodule detection in clinical practice. In this study, the authors further verify that multiprojection chest radiography can greatly improve the performance of a computer-aided diagnostic (CAD) scheme. Methods: Our database consisted of 59 subjects, including 43 subjects with 45 nodules and 16 subjects without nodules. The 45 nodules included 7 real and 38 simulated ones. The authors developed a conventional CAD scheme and a new fusion CAD scheme to detect lung nodules. The conventional CAD scheme consisted of four steps for (1) identification of initial nodule candidates inside lungs, (2) nodule candidate segmentation based on dynamic programming, (3) extraction of 33 features from nodule candidates, and (4) false positive reduction using a piecewise linear classifier. The conventional CAD scheme processed each of the three projection images of a subject independently and discarded the correlation information between the three images. The fusion CAD scheme included the four steps in the conventional CAD scheme and two additional steps for (5) registration of all candidates in the three images of a subject, and (6) integration of correlation information between the registered candidates in the three images. The integration step retained all candidates detected at least twice in the three images of a subject and removed those detected only once in the three images as false positives. A leave-one-subject-out testing method was used for evaluation of the performance levels of the two CAD schemes. Results: At the sensitivities of 70%, 65%, and 60%, our conventional CAD scheme reported 14.7, 11.3, and 8.6 false positives per image, respectively, whereas our fusion CAD scheme reported 3.9, 1.9, and 1.2 false positives per image, and 5.5, 2.8, and 1.7 false positives per patient, respectively. The low performance of the conventional CAD scheme may be attributed to the high noise level in chest radiography, and the small size and low contrast of most nodules. Conclusions: This study indicated that the fusion of correlation information in multiprojection chest radiography can markedly improve the performance of CAD scheme for lung nodule detection.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-117: Verification Method for the Detection Accuracy of Automatic Winston Lutz Test

Purpose: Winston Lutz test (WLT) has been a standard QA procedure performed prior to SRS treatment, to verify the mechanical iso-center setup accuracy upon different Gantry/Couch movements. Several detection algorithms exist,for analyzing the ball-radiation field alignment automatically. However, the accuracy of these algorithms have not been fully addressed. Here, we reveal the possible errors arise from each step in WLT, and verify the software detection accuracy with the Rectilinear Phantom Pointer (RLPP), a tool commonly used for aligning treatment plan coordinate with mechanical iso-center. Methods: WLT was performed with the radio-opaque ball mounted on a MIS and irradiated onto EDR2 films. The films were scanned and processed with an in-house Matlab program for automatic iso-center detection. Tests were also performed to identify the errors arise from setup, film development and scanning process. The radioopaque ball was then mounted onto the RLPP, and offset laterally and longitudinally in 7 known positions ( 0, ±0.2, ±0.5, ±0.8 mm) manually for irradiations. The gantry and couch was set to zero degree for all irradiation. The same scanned images were processed repeatedly to check the repeatability of the software. Results: Miminal discrepancies (mean=0.05mm) were detected with 2 films overlapped and irradiated but developed separately. This reveals the error arise from film processor and scanner alone. Maximum setup errors were found to be around 0.2mm, by analyzing data collected from 10 irradiations over 2 months. For the known shift introduced using the RLPP, the results agree with the manual offset, and fit linearly (R{sup 2}>0.99) when plotted relative to the first ball with zero shift. Conclusion: We systematically reveal the possible errors arise from each step in WLT, and introduce a simple method to verify the detection accuracy of our in-house software using a clinically available tool.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP4-03: Anomaly Detection of Respiratory Motion by Use of Singular Spectrum Analysis

Purpose: The implementation and realization of automatic anomaly detection of respiratory motion is a very important technique to prevent accidental damage during radiation therapy. Here, we propose an automatic anomaly detection method using singular value decomposition analysis. Methods: The anomaly detection procedure consists of four parts:1) measurement of normal respiratory motion data of a patient2) calculation of a trajectory matrix representing normal time-series feature3) real-time monitoring and calculation of a trajectory matrix of real-time data.4) calculation of an anomaly score from the similarity of the two feature matrices. Patient motion was observed by a marker-less tracking system using a depth camera. Results: Two types of motion e.g. cough and sudden stop of breathing were successfully detected in our real-time application. Conclusion: Automatic anomaly detection of respiratory motion using singular spectrum analysis was successful in the cough and sudden stop of breathing. The clinical use of this algorithm will be very hopeful. This work was supported by JSPS KAKENHI Grant Number 15K08703.

60 APPLIED LIFE SCIENCES↗

Recurrent Neural Network Attention Mechanisms for Interpretable System Log Anomaly Detection

Deep learning has recently demonstrated state-of-the art performance on key tasks related to the maintenance of computer systems, such as intrusion detection, denial of service attack detection, hardware and software system failures, and malware detection. In these contexts, model interpretability is vital for administrator and analyst to trust and act on the automated analysis of machine learning models. Deep learning methods have been criticized as black box oracles which allow limited insight into decision factors. In this work we seek to "bridge the gap'' between the impressive performance of deep learning models and the need for interpretable model introspection. To this end we present recurrent neural network (RNN) language models augmented with attention for anomaly detection in system logs. Our methods are generally applicable to any computer system and logging source. By incorporating attention variants into our RNN language models we create opportunities for model introspection and analysis without sacrificing state-of-the art performance. We demonstrate model performance and illustrate model interpretability on an intrusion detection task using the Los Alamos National Laboratory (LANL) cyber security dataset, reporting upward of 0.99 area under the receiver operator characteristic curve despite being trained only on a single day's worth of data.

Anomaly detection, Attention, Recurrent Neural Net↗

acdc – Automated Contamination Detection and Confidence estimation for single-cell genome data

Abstract Background A major obstacle in single-cell sequencing is sample contamination with foreign DNA. To guarantee clean genome assemblies and to prevent the introduction of contamination into public databases, considerable quality control efforts are put into post-sequencing analysis. Contamination screening generally relies on reference-based methods such as database alignment or marker gene search, which limits the set of detectable contaminants to organisms with closely related reference species. As genomic coverage in the tree of life is highly fragmented, there is an urgent need for a reference-free methodology for contaminant identification in sequence data. Results We present acdc, a tool specifically developed to aid the quality control process of genomic sequence data. By combining supervised and unsupervised methods, it reliably detects both known and de novo contaminants. First, 16S rRNA gene prediction and the inclusion of ultrafast exact alignment techniques allow sequence classification using existing knowledge from databases. Second, reference-free inspection is enabled by the use of state-of-the-art machine learning techniques that include fast, non-linear dimensionality reduction of oligonucleotide signatures and subsequent clustering algorithms that automatically estimate the number of clusters. The latter also enables the removal of any contaminant, yielding a clean sample. Furthermore, given the data complexity and the ill-posedness of clustering, acdc employs bootstrapping techniques to provide statistically profound confidence values. Tested on a large number of samples from diverse sequencing projects, our software is able to quickly and accurately identify contamination. Results are displayed in an interactive user interface. Acdc can be run from the web as well as a dedicated command line application, which allows easy integration into large sequencing project analysis workflows. Conclusions Acdc can reliably detect contamination in single-cell genome data. In addition to database-driven detection, it complements existing tools by its unsupervised techniques, which allow for the detection of de novo contaminants. Our contribution has the potential to drastically reduce the amount of resources put into these processes, particularly in the context of limited availability of reference species. As single-cell genome data continues to grow rapidly, acdc adds to the toolkit of crucial quality assurance tools.

59 BASIC BIOLOGICAL SCIENCES↗

Gravity monitoring of CO{sub 2} movement during sequestration: Model studies

Sequestration/enhanced oil recovery (EOR) petroleum reservoirs have relatively thin injection intervals with multiple fluid components (oil, hydrocarbon gas, brine, and carbon dioxide, or CO{sub 2}), whereas brine formations usually have much thicker injection intervals and only two components (brine and CO{sub 2}). Coal formations undergoing methane extraction tend to be thin (3-10 m) but shallow compared to either EOR or brine formations. Injecting CO{sub 2} into an oil reservoir decreases the bulk density in the reservoir. The spatial pattern of the change in the vertical component of gravity (G{sub z}) is correlated directly with the net change in reservoir density. Furthermore, time-lapse changes in the borehole G{sub z} clearly identify the vertical section of the reservoir where fluid saturations are changing. The CO{sub 2}-brine front, on the order of 1 km within a 20-m-thick brine formation at 1900-m depth with 30% CO{sub 2} and 70% brine saturations, respectively, produced a -10-{mu} Gal surface gravity anomaly. Such an anomaly would be detectable in the field. The amount of CO{sub 2} in a coal-bed methane scenario did not produce a large enough surface gravity response; however, we would expect that for an industrial-size injection, the surface gravity response would be measurable. Gravity inversions in all three scenarios illustrate that the general position of density changes caused by CO{sub 2} can be recovered but not the absolute value of the change. Analysis of the spatial resolution and detectability limits shows that gravity measurements could, under certain circumstances, be used as a lower-cost alternative to seismic measurements.

01 COAL, LIGNITE, AND PEAT↗

Deep PDF parsing to extract features for detecting embedded malware.

The number of PDF files with embedded malicious code has risen significantly in the past few years. This is due to the portability of the file format, the ways Adobe Reader recovers from corrupt PDF files, the addition of many multimedia and scripting extensions to the file format, and many format properties the malware author may use to disguise the presence of malware. Current research focuses on executable, MS Office, and HTML formats. In this paper, several features and properties of PDF Files are identified. Features are extracted using an instrumented open source PDF viewer. The feature descriptions of benign and malicious PDFs can be used to construct a machine learning model for detecting possible malware in future PDF files. The detection rate of PDF malware by current antivirus software is very low. A PDF file is easy to edit and manipulate because it is a text format, providing a low barrier to malware authors. Analyzing PDF files for malware is nonetheless difficult because of (a) the complexity of the formatting language, (b) the parsing idiosyncrasies in Adobe Reader, and (c) undocumented correction techniques employed in Adobe Reader. In May 2011, Esparza demonstrated that PDF malware could be hidden from 42 of 43 antivirus packages by combining multiple obfuscation techniques [4]. One reason current antivirus software fails is the ease of varying byte sequences in PDF malware, thereby rendering conventional signature-based virus detection useless. The compression and encryption functions produce sequences of bytes that are each functions of multiple input bytes. As a result, padding the malware payload with some whitespace before compression/encryption can change many of the bytes in the final payload. In this study we analyzed a corpus of 2591 benign and 87 malicious PDF files. While this corpus is admittedly small, it allowed us to test a system for collecting indicators of embedded PDF malware. We will call these indicators features throughout the rest of this report. The features are extracted using an instrumented PDF viewer, and are the inputs to a prediction model that scores the likelihood of a PDF file containing malware. The prediction model is constructed from a sample of labeled data by a machine learning algorithm (specifically, decision tree ensemble learning). Preliminary experiments show that the model is able to detect half of the PDF malware in the corpus with zero false alarms. We conclude the report with suggestions for extending this work to detect a greater variety of PDF malware.

99 GENERAL AND MISCELLANEOUS↗

Standoff ultraviolet raman scattering detection of trace levels of explosives.

Ultraviolet (UV) Raman scattering with a 244-nm laser is evaluated for standoff detection of explosive compounds. The measured Raman scattering albedo is incorporated into a performance model that focused on standoff detection of trace levels of explosives. This model shows that detection at {approx}100 m would likely require tens of seconds, discouraging application at such ranges, and prohibiting search-mode detection, while leaving open the possibility of short-range point-and-stare detection. UV Raman spectra are also acquired for a number of anticipated background surfaces: tile, concrete, aluminum, cloth, and two different car paints (black and silver). While these spectra contained features in the same spectral range as those for TNT, we do not observe any spectra similar to that of TNT.

36 MATERIALS SCIENCE↗

NRC Job Code V6060: Extended In-Situ and Real Time Monitoring. Task 4: Detection and Monitoring of Leaks at Nuclear Power Plants External to Structures

In support of Task 4 of the NRC study on compliance with 10 CFR part 20.1406, minimization of contamination, Argonne National Laboratory (ANL) conducted a one-year scoping study, in concert with a parallel study performed by NRC/NRR staff, on monitoring for leaks at nuclear power plants (NPPs) external to structures. The objective of this task-4 study is to identify and assess those sensors and monitoring techniques for early detection of abnormal radioactive releases from the engineered facility structures, systems and components (SSCs) to the surrounding underground environment in existing NPPs and planned new reactors. As such, methods of interest include: (1) detection of anomalous water content of soils surrounding SSCs, (2) radionuclides contained in the leaking water, and (3) secondary signals such as temperature. ANL work scope includes mainly to (1) identify, in concert with the nuclear industry, the sensors and techniques that have most promise to detect radionuclides and/or associated chemical releases from SSCs of existing NPPs and (2) review and provide comments on the results of the NRC/NRR staff scoping study to identify candidate technologies. This report constitutes the ANL deliverable of the task-4 study. It covers a survey of sensor technologies and leak detection methods currently applied to leak monitoring at NPPs. The survey also provides a technology evaluation that identifies their strength and deficiency based on their detection speed, sensitivity, range and reliability. Emerging advanced technologies that are potentially capable of locating releases, identifying the radionuclides, and estimating their concentrations and distributions are also included in the report along with suggestions of required further research and development.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Nuclear Smuggling Detection and Deterrence FY 2016 Data Analysis Annual Report

The National Nuclear Security Administration’s Office of Nuclear Smuggling Detection and Deterrence (NSDD) has facilitated the installation of more than 3,500 radiation portal monitors (RPMs) at 606 sites in 56 countries worldwide. This collection of RPMs represents the world’s largest network of radiation detectors and provides one element in the defense-in-depth approach that supports the Global Nuclear Detection Architecture. These systems support NSDD’s mission to build partner country capability to deter, detect, and interdict the illicit transport of radiological and fissile material through strategic points of entry and exit at seaports, airports, and border crossings. NSDD works collaboratively with partner countries and international organizations to optimize the operation of these RPMs. The large amount of data provided by NSDD partner countries highlights the close cooperation and partnerships NSDD has built with 56 countries around the world. Thirty-seven of these countries shared at least some RPM-related data with NSDD in fiscal year 2016. This significant level of data sharing is a key element that distinguishes the NSDD office as unique among nuclear nonproliferation programs and initiatives: NSDD can provide specific, objective, data-driven decisions and support for sustaining the radiation detection systems it helped deploy. This data analysis report summarizes and aggregates the RPM data provided to the NSDD office for analysis and review in fiscal year 2016. The data can be used to describe RPM performance and characterize the wide diversity of NSDD deployment sites. For example, NSDD deploys detector systems across sites with natural background radiation levels that can vary by a factor of approximately six from site to site. Some lanes have few occupancies, whereas others have approximately 8,000 occupancies per day and the different types of cargo that travel through a site can result in site-wide alarm rates that range from near 0% at some sites to above 3% at others. Based on the data received, the global average uptime for NSDD RPMs was above 96% for fiscal year 2016. NSDD takes all of these factors into account in making recommendations to partner countries on how to most effectively manage and maintain site operations. NSDD utilizes reports and other information products created by data analysts to efficiently allocate the resources needed to detect and ultimately interdict illicit nuclear and radiological material.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Pressure-Based Inversion and Data Assimilation System (PIDAS) for CO 2 Leakage Detection (Final Report)

This project aims to develop a Pressure-based Inversion and Data Assimilation System (PIDAS) for detecting CO 2 leakage from storage formations. Carbon capture, utilization, and sequestration (CCUS) has the potential to enable deep reductions in global carbon emissions if high storage efficiency can be achieved. A major hurdle to industrial-scale implementation of geological carbon sequestration (GCS) projects is the potential migration of fluids (either brine or injected CO 2 ) from the storage formations and the resulting legal and financial liabilities. The capability to accurately identify leakage pathways by which stored CO 2 could leak, has leaked, or is leaking from the targeted storage zone is thus of paramount importance to site licensees and regulators. Although many MVA techniques have been devised, pressure-based monitoring technology remains the most sensitive and reliable technique for early detection. Pressure-based monitoring has consistently received the highest score in terms of benefit/cost ratio and it provides the greatest potential for leakage detection with broad areal coverage. Under this project we have (a) demonstrated the utility of the proposed well testing technique for leakage detection through integrated theoretical and numerical analysis, laboratory experiments, and field tests; (b) developed effective data analysis and inversion algorithms for identifying leakage pathways by fusing data generated during well testing; (c) provided a designing tool for maximizing the utility of the developed PIDAS tool for early leakage detection.

02 PETROLEUM↗

Multimodal Deep Learning for Flaw Detection in Software Programs

We explore the use of multiple deep learning models for detecting flaws in software programs. Current, standard approaches for flaw detection rely on a single representation of a software program (e.g., source code or a program binary). We illustrate that, by using techniques from multimodal deep learning, we can simultaneously leverage multiple representations of software programs to improve flaw detection over single representation analyses. Specifically, we adapt three deep learning models from the multimodal learning literature for use in flaw detection and demonstrate how these models outperform traditional deep learning models. We present results on detecting software flaws using the Juliet Test Suite and Linux Kernel.

97 MATHEMATICS AND COMPUTING↗

Evaluation of Minimum Detectable Activities for Stack Sample Analyses

The Rad-NESHAP program takes samples at major point sources to track how much of select nuclides are being emitted out of the stack. Samples are taken at the site where the radiological operations are being performed. The samples are then sent to analytical laboratories for analysis to determine what nuclides exist in the sample. However, due to the sensitivity of the instruments, false positives are often reported. To reduce the number of false positives, the results reported from the analytical labs are compared to set detection limits. Anything below the set detection limit is considered part of the background while anything above the limit is considered a positive hit. Therefore, the detection limit must be set low enough that any false negatives do not result in a significant dose missed at the end of the year but high enough that there are not enough false positives to skew the annual dose being reported. All detection limits listed in this section for the analyses below were designed to meet the stated equivalent emissions rate and subsequent off-site doses. These minimum detectable activities (MDAs) were developed in the 1990s and documented in the memo cited for each analysis below. These limits and memos are all currently referenced in the Quality Assurance Project Plan (QAPP) for the Rad-NESHAP Compliance Task, which is being updated to a Project Implementation Plan (PIP) concurrently with this document. As part of this update process, the original MDAs defined in this section needed to be verified that they were still conservative and meet the off-site dose levels stated.

2019 MDA↗