Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Configuration Management”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

ALTERNATIVES OF MACCS2 IN LANL DISPERSION ANALYSIS FOR ONSITE AND OFFSITE DOSES

In modeling atmospheric dispersion to determine accidental release of radiological material, one of the common statistical analysis tools used at Los Alamos National Laboratory (LANL) is MELCOR Accident Consequence Code System, Version 2 (MACCS2). MACCS2, however, has some limitations and shortfalls for both onsite and offsite applications. Alternative computer codes, which could provide more realistic calculations, are being investigated for use at LANL. In the Yucca Mountain Project (YMP), the suitability of MACCS2 for the calculation of onsite worker doses was a concern; therefore, ARCON96 was chosen to replace MACCS2. YMP's use of ARCON96 provided results which clearly demonstrated the program's merit for onsite worker safety analyses in a wide range of complex configurations and scenarios. For offsite public exposures, the conservatism of MACCS2 on the treatment of turbulence phenomena at LANL is examined in this paper. The results show a factor of at least two conservatism in calculated public doses. The new EPA air quality model, AERMOD, which implements advanced meteorological turbulence calculations, is a good candidate for LANL applications to provide more confidence in the accuracy of offsite public dose projections.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Transportation Cask for Bare High Burnup Used Nuclear Fuel - 16362

A conceptual design for a reusable transportation cask (the 6625B-HB) capable of transporting boiling water reactor (BWR) and pressurized water reactor (PWR) used nuclear fuel (UNF) assemblies, including high burnup UNF, was produced for the Department of Energy (DOE) by AREVA. This cask could be configured to ship these assemblies either as bare fuel or fuel loaded into single-assembly damaged fuel cans (DFCs). The 6625B-HB cask has been designed with reasonable assurance it can be certified by the Nuclear Regulatory Commission (NRC) under 10 CFR Part 71 based on AREVA TN's experience with the MP197HB (a transportation cask designed to ship high burnup UNF in a dry storage canister), fabricated within existing facilities, used by most utilities, and transported by rail. The level of detail developed for the 6625B-HB is intended to support analyses and planning activities that DOE is performing in laying the groundwork for an integrated waste management system, which includes preparing for future large-scale transport of UNF to consolidated interim storage or disposal facilities. The details of the conceptual design include cask characteristics (e.g., capacity, dimensions, and masses), characteristics of the UNF that could be shipped in this cask system concept, estimates of costs to fabricate this cask system, an assessment of operational activity durations and associated cumulative doses for loading and unloading this cask system, and identification of potential limitations or anticipated licensing considerations of relevance for this cask system. This design concept for a reusable transportation cask would enhance the high-burnup fuel assembly carrying capacity as compared to other NRC-certified transportation casks and, unlike welded canister systems, could be used for shipment of bare UNF assemblies taken directly from reactor spent fuel pools (SFPs). (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Virtual machine provisioning, code management, and data movement design for the Fermilab HEPCloud Facility

The Fermilab HEPCloud Facility Project has as its goal to extend the current Fermilab facility interface to provide transparent access to disparate resources including commercial and community clouds, grid federations, and HPC centers. This facility enables experiments to perform the full spectrum of computing tasks, including data-intensive simulation and reconstruction. We have evaluated the use of the commercial cloud to provide elasticity to respond to peaks of demand without overprovisioning local resources. Full scale data-intensive workflows have been successfully completed on Amazon Web Services for two High Energy Physics Experiments, CMS and NOνA, at the scale of 58000 simultaneous cores. This paper describes the significant improvements that were made to the virtual machine provisioning system, code caching system, and data movement system to accomplish this work. The virtual image provisioning and contextualization service was extended to multiple AWS regions, and to support experiment-specific data configurations. A prototype Decision Engine was written to determine the optimal availability zone and instance type to run on, minimizing cost and job interruptions. We have deployed a scalable on-demand caching service to deliver code and database information to jobs running on the commercial cloud. It uses the frontiersquid server and CERN VM File System (CVMFS) clients on EC2 instances and utilizes various services provided by AWS to build the infrastructure (stack). We discuss the architecture and load testing benchmarks on the squid servers. We also describe various approaches that were evaluated to transport experimental data to and from the cloud, and the optimal solutions that were used for the bulk of the data transport. Finally, we summarize lessons learned from this scale test, and our future plans to expand and improve the Fermilab HEP Cloud Facility.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Apparatus and method for radioactive waste screening

An apparatus and method relating to screening radioactive waste are disclosed for ensuring that at least one calculated parameter for the measurement data of a sample falls within a range between an upper limit and a lower limit prior to the sample being packaged for disposal. The apparatus includes a radiation detector configured for detecting radioactivity and radionuclide content of the of the sample of radioactive waste and generating measurement data in response thereto, and a collimator including at least one aperture to direct a field of view of the radiation detector. The method includes measuring a radioactive content of a sample, and calculating one or more parameters from the radioactive content of the sample.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Salt Processing Through Ion Exchange at the Savannah River Site Selection of Exchange Media and Column Configuration - 9198

The Department of Energy (DOE) has developed, modeled, and tested several different ion exchange media and column designs for cesium removal. One elutable resin and one non-elutable resin were considered for this salt processing application. Deployment of non-elutable Crystalline Silicotitanate and elutable Resorcinol Formaldehyde in several different column configurations were assessed in a formal Systems Engineering Evaluation (SEE). Salt solutions were selected that would allow a grouping of non-compliant tanks to be closed. Tests were run with the elutable resin to determine compatibility with the resin configuration required for an in-tank ion exchange system. Models were run to estimate the ion exchange cycles required with the two resins in several column configurations. Material balance calculations were performed to estimate the impact on the High Level Waste (HLW) system at the Savannah River Site (SRS). Conceptual process diagrams were used to support the hazard analysis. Data from the hazard analysis was used to determine the relative impact on safety. This report will discuss the technical inputs, SEE methods, results and path forward to complete the technical maturation of ion exchange.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

ACDT: Architected Composite Data Types Trading-in Unfettered Data Access for Improved Execution

With Exascale performance and its challenges in mind, one ubiquitous concern among architects is energy efficiency. Petascale systems projected to Exascale systems are unsustainable at current power consumption rates. One major contributor to system-wide power consumption is the number of memory operations leading to data movement and management techniques applied by the runtime system. To address this problem, we present the concept of the Architected Composite Data Types (ACDT) framework. The framework is made aware of data composites, assigning them a specific layout, transformations and operators. Data manipulation overhead is amortized over a larger number of elements and program performance and power efficiency can be significantly improved. We developed the fundamentals of an ACDT framework on a massively multithreaded adaptive runtime system geared towards Exascale clusters. Showcasing the capability of ACDT, we exercised the framework with two representative processing kernels - Matrix Vector Multiply and the Cholesky Decomposition – applied to sparse matrices. As transformation modules, we applied optimized compress/decompress engines and configured invariant operators for maximum energy/performance efficiency. Additionally, we explored two different approaches based on transformation opaqueness in relation to the application. Under the first approach, the application is agnostic to compression and decompression activity. Such approach entails minimal changes to the original application code, but leaves out potential applicationspecific optimizations. The second approach exposes the decompression process to the application, hereby exposing optimization opportunities that can only be exploited with application knowledge. The experimental results show that the two approaches have their strengths in HW and SW respectively, where the SW approach can yield performance and power improvements that are an order of magnitude better than ACDT-oblivious, hand-optimized implementations.We consider the ACDT runtime framework an important component of compute nodes that will lead towards power efficient Exascale clusters.

exascale↗

Designs for Risk Evaluation and Management

The Designs for Risk Evaluation and Management (DREAM) tool was developed as part of the effort to quantify the risk of geologic storage of carbon dioxide (CO 2 ) under the U.S. Department of Energy's National Risk Assessment Partnership (NRAP). DREAM is an optimization tool created to identify optimal monitoring schemes that minimize the time to first detection of CO 2 leakage from a subsurface storage formation. DREAM acts as a post-processer on user-provided output from subsurface leakage simulations. While DREAM was developed for CO 2 leakage scenarios, it is applicable to any subsurface leakage simulation of the same output format. The DREAM tool is comprised of three main components: (1) a Java wizard used to configure and execute the simulations, (2) a visualization tool to view the domain space and optimization results, and (3) a plotting tool used to analyze the results. A secondary Java application is provided to aid users in converting common American Standard Code for Information Interchange (ASCII) output data to the standard DREAM hierarchical data format (HDF5). DREAM employs a simulated annealing approach that searches the solution space by iteratively mutating potential monitoring schemes built of various configurations of monitoring locations and leak detection parameters. This approach has proven to be orders of magnitude faster than an exhaustive search of the entire solution space. The user's manual illustrates the program graphical user interface (GUI), describes the tool inputs, and includes an example application.

(Ruprecht) Yonkofski, Catherine↗

LH CO 2 MENT Colorado Project (Final Report)

The objective of Electricore’s pre-FEED project “LH CO 2 MENT COLORADO PROJECT” is to accelerate the implementation of a 1.5 million tonnes per year (TPY), and first-of-a-kind (FOAK) at world scale, Svante VeloxoTherm™ carbon capture plant. This project represents a quantum leap to a large-scale facility that will launch Svante’s carbon capture technology into the next era of accomplishments and market acceptance. By completing the Front-End Loading (FEL) Feasibility Study Report (FEL-2) for a fit-for-purpose design at the HOLCIM cement plant, located near Florence Colorado, USA, this technology can be proven as the future of large-scale deployment for carbon capture and storage. This carbon capture plant was designed with the goal of reaching a target of near Net Zero Emissions by capturing 90% of the carbon dioxide (CO 2 ) emissions from the HOLCIM cement plant and from the boiler which produces steam required to regenerate the adsorbent. Additionally, this project will be leveraging a renewable Power Purchase Agreement (PPA) using solar energy to acquire power at the target price of 0.04 $/kWh or less. In its current configuration CO 2 emissions from the HOLCIM cement plant is around 700 – 800 kg/ton of clinker produced. The proposed new carbon capture plant will allow a reduction of CO 2 emissions to about 100 kg/ton of clinker produced. The scope of work consists of the process design and capital & operating cost estimation (Class IV) for a total plant capacity of 4,750 TPD of pipeline grade CO 2 . The Svante VeloxoTherm™ technology is comprised of a Rotary Adsorption Machine (RAM) for intensified Thermal Swing Adsorption (TSA) using Structured Adsorbent Beds (SABs) and related Balance of Plant (BOP), including CO 2 compression. A business case (financial analysis) evaluation has been undertaken for the Owner’s management review. Recommendations on how best to proceed to the next stage of the project have been conveyed and are documented within this report. This analysis has relied on a detailed and comprehensive Project Financial Model, evaluating the Total Project IRR (after tax, unlevered, and including all forecast 45Q PTCs and 100% tax efficiency) – the project financial analysis (as opposed to standard TEA analysis) only considered a 12 year plant economic lifetime as a result of 45Q being the sole driver considered at this stage. The Total Project IRR was evaluated across a large number of potential scenarios. The evaluation demonstrated that if the 45Q PTD is increased to $85/MT for sequestration, there are a large number of feasible scenarios which demonstrate economic returns.

01 COAL, LIGNITE, AND PEAT↗

Gaseous fission product management for molten salt reactors and vented fuel systems

Fission gas disposal is one of the unresolved difficulties for Molten Salt Reactors (MSRs) and advanced reactors with vented fuel systems. As these systems operate, they produce many radioactive isotopes of xenon and krypton (e.g. {sup 135}Xe t{sub 1/2} = 9.14 hours and {sup 85}Kr t{sub 1/2}= 10.73 years). Removing these gases proves vital to the success of such reactor designs for two reasons. First, the gases act as large neutron sinks which decrease reactivity and must be counterbalanced by increasing fuel loading. Second, for MSRs, inert fission product gases naturally separate quickly from high temperature salts, thus creating high vapor pressure which poses safety concerns. For advanced reactors with solid vented fuel, the gases are allowed to escape into an off-gas system and thus must be managed. Because of time delays in transport of fission product gases in vented fuel systems, some of the shorter-lived radionuclides will decay away thereby reducing the fission gas source term relative to an MSR. To calculate the fission gas source term of a typical molten salt reactor, we modeled a 1000 MWe graphite moderated thorium MSR similar to that detailed in Mathieu et al. [1]. The fuel salt used in these calculations was LiF (78 mole percent) - (HN)F 4 (22 mole percent) with a heavy nuclide composition of 3.86% {sup 233}U and 96.14% {sup 232}Th by mass. Before we can remove the fission product gases produced by this reactor configuration, we must first develop an appropriate storage mechanism. The gases could be stored in pressurized containers but then one must be concerned about bottle failure. Methods to trap noble gases in matrices are expensive and complex. Alternatively, there are direct storage/disposal options: direct injection into the Earth or injecting a grout-based product into the Earth. Advances in drilling technologies, hydro fracture technologies, and methods for the sequestration of carbon dioxide from fossil fuel plants are creating new options for disposal of fission gas wastes. In each option, lithostatic pressure, a kilometer or more underground, eliminates the pressure driving force for noble gas release and dissolves any untrapped gas in deep groundwater or into incorporated solid waste forms. The options, challenges, and potential for these methods to dispose of gaseous fission products are described. With this research, we hope to help both MSRs and other advanced reactors come one step closer to commercialization. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Achievements and process improvements in processing transuranic waste at the TRU Waste Processing Center - 15488

Wastren Advantage, Inc., (WAI) is the DOE Prime contractor for the TRU Waste Processing Center (TWPC) located in Oak Ridge, TN. This paper highlights the TWPCs specific achievements and process improvements associated with both Contact (CH) and Remote Handled (RH), Transuranic (TRU) waste receipt processing and repackaging for disposal. The five key improvement areas and achievements include: - The TWPC installed, tested and operated successfully the Drum Venting System (DVS) to vent over-packed CH-TRU waste drums in several configurations including 55-gallon drums over-packed in 79 or 85-gallon drums. - A new Remote Drum Opener (RDO) system was designed, tested and placed in service to vent drums discovered in overpack boxes in the Box Breakdown Area and to vent overpack configurations that could not be handled in the standard DVS (e.g., 110 gallon overpacks and multiple drum configurations). - The Cask Processing Enclosure (CPE) approach to repackaging RH-TRU waste contained in concrete casks was developed and implemented - Hot Cell outage to incorporate planned equipment modifications and improvements to maintain processing rates. - To improve certification and segregation of CH-TRU from drums that meet Low Level Waste criteria for disposal at Nevada the TWPC added additional equipment/facilities for Non-Destructive Assay (NDA) and Real Time Radiography (RTR). (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Optimizing Short-Term Operation of a FIRES-like Industrial Heat Supply Thermal Energy Storage System

The Firebrick Resistance-heated Energy-storage System (FIRES) is under development at MIT for two applications: (1) integration with the Nuclear Air-Brayton Combined Cycle (NACC), a high-performance power conversion system (PCS) that may be used with high- temperature advanced reactors; and (2) industrial heat supply. This paper describes some key features of FIRES and equivalent systems configured for industrial heat supply and presents an assessment of the revenue achievable by a system operating under the conditions expected for early demonstration FIRES installations. The greatest technical challenge of the 21. century is likely to be the effort to minimize the damage caused by global climate change. This effort will require massive reductions in greenhouse gas (GHG) emissions throughout our economy and a transition to an electric power system driven entirely by very-low-carbon generators. Many investigators agree that this will require a substantial increase in electricity generation and in the use of nuclear power, and there is growing awareness that this will also require new technologies and systems for managing and storing energy and matching intermittent supply of renewable resources with electricity demand. Thermal energy storage systems (TESS) will, in some applications, be much more cost effective than the more popular and widely discussed battery electric storage systems and may provide unique capabilities. The Firebrick Resistance-heated Energy-storage System (FIRES) is under development at MIT for two applications: (1) integration with the Nuclear Air-Brayton Combined Cycle (NACC), a high-performance power conversion system (PCS) that may be used with high-temperature advanced reactors like the Fluoride-salt-cooled High-temperature Reactor (FHR), molten salt reactor (MSR) and sodium-cooled fast reactors (SFR); and (2) industrial heat supply. FIRES installations include a stack of refractory firebrick with imbedded electric heaters and airflow channels, a compressor or air blower, and a duct system to connect the firebrick with the heat demand (turbine or industrial customer). Analysis of the FIRES design space has shown that the concept is suitable for a wide range of peak operating temperatures (from about 200 deg.C up to at least 1800 deg. C) and pressures (from ambient to at least 20 atmospheres) and offers very high energy density (up to 1 MWh per cubic meter of firebrick for high temperature systems) at very low cost (as low as $5/kWh). These results favor early demonstration of FIRES. If the cost target of $5/kWh for FIRES systems were achieved, even the lowest expected operating income calculated here could cover the capital cost of a 10 MWh system in a single year. If the FIRES system were assumed to operate for at least 10 years, this level of operating income could readily recover a capital investment up to $50/kWh, which is simultaneously much cheaper than the costs expected for near-future battery systems (in excess of $200/kWh) and much more expensive than the small, low temperature firebrick systems already available for domestic heating. This provides a large margin for unexpected development costs and other uncertainties. FIRES would set a minimum price of electricity near that of natural gas-improving nuclear, wind, and solar economics while reducing greenhouse gas emissions from the industrial sector. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Rail Shock and Vibration Pre-Test Modeling of a Used Nuclear Fuel Assembly

The U.S. Department of Energy Office of Nuclear Energy (DOE-NE), Office of Fuel Cycle Technology, has established the Used Fuel Disposition Campaign (UFDC) to conduct the research and development activities related to storage, transportation, and disposal of used nuclear fuel (UNF) and high-level radioactive waste (HLW). The mission of the UFDC is to identify alternatives and conduct scientific research and technology development to enable storage, transportation and disposal of used nuclear fuel and HLW generated by existing and future nuclear fuel cycles. The Storage and Transportation staff within the UFDC is responsible for addressing issues regarding the long-term or extended storage (ES) of UNF and its subsequent transportation. Available information is not sufficient to determine the ability of ES UNF, including high-burnup fuel, to withstand shock and vibration forces that could occur when the UNF is shipped by rail from nuclear power plant sites to a storage or disposal facility. There are three major gaps in the available information – 1) the forces that UNF assemblies would be subjected to when transported by rail, 2) the mechanical characteristics of fuel rod cladding, which is an essential structure for controlling the geometry of the UNF, a safety related feature, and 3) modeling methodologies to evaluate multiple possible degradation or damage mechanisms over the UNF lifetime. In order to address the first gap, options for tests to determine the physical response of surrogate UNF assemblies subjected to shock and vibration forces that are expected to be experienced during normal conditions of transportation (NCT) by rail must be identified and evaluated. The objective of the rail shock and vibration tests is to obtain data that will help researchers understand the mechanical loads that ES UNF assemblies would be subjected to under normal conditions of transportation and to fortify the computer modeling that will be necessary to evaluate the impact those loads may have on the integrity of the UNF assembly. The shock and vibration testing along with computer modeling is a vital part of research to achieve closure of a gap in information related to the ability of ES UNF to maintain its safety function when subjected to NCT. In support of this effort, preliminary structural dynamics modeling is presented herein. The modeling investigates the rigidity of a hypothetical cask and cradle structure by comparing it to a monolithic concrete mass. The concrete mass represents a practical option for achieving the necessary cask and cradle mass on a flatbed railcar, but this comparative modeling study investigates whether or not the dynamic loads transmitted through a monolithic concrete configuration are adequately representative of a realistic cask and cradle system. This modeling highlights the need for rail testing by reporting the phenomenon of structural transmissibility. As shown herein, this structural transmissibility can cause an amplification of shock and vibration loads through the structure, which could potentially lead to accelerated mechanical degradation of UNF under NCT.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Pumped Thermal Energy Storage Cycle with Capacity for Concentrated Solar Power Integration

Pumped thermal energy storage (PTES) is a grid-scale energy management technology that stores electricity in the form of thermal energy. A number of PTES systems have been proposed using different thermodynamic cycles, including a variant based on a regenerated Brayton cycle that stores the thermal energy in liquid storage media (such as molten salts) via heat exchangers. This has several advantages, including the possibility to consider hybrid 'solar-PTES' systems employing technology developed by the concentrated solar power (CSP) industry. Such a hybrid system could charge the same hot stores using either solar energy or off-peak electricity (e.g, from nearby wind farms), increasing the capacity factor of the plant while employing the same heat engine during discharge. In this paper, two different configurations of solar-PTES systems are proposed and studied numerically: (i) a configuration in which an existing CSP plant is retrofitted with a Brayton heat pump, and (ii) a configuration in which a new hybrid plant uses the Brayton cycle both for charge and discharge. In both cases, the need to absorb and reject heat at conditions close to ambient temperature requires the Brayton cycle to incorporate intercooled stages at the cold side of the cycle. On the other hand, the intercooling process increases the minimum temperature of the cold stores, meaning that widely available and nonflammable antifreeze solutions (such as water-ethylene glycol) may be used as the cold storage medium.

14 SOLAR ENERGY↗

Using butterfly survey data to model habitat associations in urban developments

Abstract One approach for measuring the potential biodiversity in new urban construction projects is through ecological models that predict how wildlife will respond. For the United Kingdom, such models have only been developed for birds, but to maximise the extent to which models represent overall biodiversity, species from different indicator groups must be considered. Here, we assess this possibility for butterflies by combining citizen science survey data with high‐resolution digital maps. We derive detailed characteristics of urban landscapes around survey sites using previously established methods and quantify their relationship to counts of adults of 18 butterfly species in urban and peri‐urban settings. Higher butterfly counts were found when traversing urban sites with larger areas of semi‐natural grassland, other managed greenspaces and adjacent arable land. Most of the butterfly community were found to have negative relationships with highly built‐up or fragmented landscapes. We found high species‐specificity for different details of urban form, particularly in habitat elements such as gardens, vegetation around railways and grass verges. Policy implications . Improving biodiversity is now part of legislation governing new construction projects from England and Wales. However, predicting quantitative changes from hypothetical land‐use modifications remains challenging. Our models provide the foundation through which butterfly abundance could be integrated into an urban biodiversity assessment tool, providing species‐ and community‐level statistics to non‐specialists from the urban planning and design sector. This would allow them to hone configurations for built surfaces, private gardens, greenspaces and wildlife areas and assess their capacity to provide residents with the intended access to nature.

Cooper, Joseph E. J.↗

Low Thermal Resistance (0.5 K/W) Ga 2 O 3 Schottky Rectifiers With Double-Side Packaging

The low thermal conductivity of Ga 2 O 3 has arguably been the most serious concern for Ga 2 O 3 power and RF devices. Despite many simulation studies, there is no experimental report on the thermal resistance of a large-area, packaged Ga 2 O 3 device. This work fills this gap by demonstrating a 15-A double-side packaged Ga 2 O 3 Schottky barrier diode (SBD) and measuring its junction-to-case thermal resistance (R θJC ) in the bottom-side- and junction-side-cooling configurations. The R θJC characterization is based on the transient dual interface method, i.e., JEDEC 51-14 standard. The R θJC of the junction- and bottom-cooled Ga 2 O 3 SBD was measured to be 0.5 K/W and 1.43 K/W, respectively, with the former R θJC lower than that of similarly-rated commercial SiC SBDs. This low R θJC is attributable to the heat extraction directly from the Schottky junction instead of through the Ga 2 O 3 chip. Here, the R θJC lower than that of commercial SiC devices proves the viability of Ga 2 O 3 devices for high-power applications and manifest the significance of proper packaging for their thermal management.

42 ENGINEERING↗

Testing of Optimized Bubbler Configuration for HLW Melter

The principal objective of this work was to determine the glass production rate increase and ancillary effects of adding more bubbler outlets to the current WTP HLW melter baseline. This was accomplished through testing on the HLW Pilot Melter (DM1200) at VSL. The DM1200 unit was selected for these tests since it was used previously with several HLW waste streams including the four tank wastes proposed for initial processing at Hanford. This melter system was also used for the development and optimization of the present baseline WTP HLW bubbler configuration for the WTP HLW melter, as well as for MACT testing for both HLW and LAW. Specific objectives of these tests were to: Conduct DM1200 melter testing with the baseline WTP bubbling configuration and as augmented with additional bubblers. Conduct DM1200 melter testing to differentiate the effects of total bubbler air flow and bubbler distribution on glass production rate and cold cap formation. Collect melter operating data including processing rate, temperatures at a variety of locations within the melter plenum space, melt pool temperature, glass melt density, and melter pressure with the baseline WTP bubbling configuration and as augmented with additional bubblers. Collect melter exhaust samples to compare particulate carryover for different bubbler configurations. Analyze all collected data to determine the effects of adding more bubblers to the WTP HLW melter to inform decisions regarding future lid re-designs. The work used a high aluminum HLW stream composition defined by ORP, for which an appropriate simulant and high waste loading glass formulation were developed and have been previously processed on the DM1200.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Budget Period 2 Summary Report Part 2: Hywind Maine Project

This project was performed under the Work for Others—Funds in Agreement FIA-14-1793 between Statoil and the Alliance for Sustainable Energy, manager and operator of the National Renewable Energy Laboratory (NREL). To support the development of a 6-MW spar-mounted offshore wind turbine, Statoil funded NREL to perform tasks in the following three categories: 1. Design and analysis 2. Wake modeling 3. Concept resource assessment. This study expands upon the work conducted in Budget Period 1 (BP1) to investigate the influence of the wake generated from an upstream turbine on a downstream turbine using Computational Fluid Dynamics (CFD) high-fidelity modeling tool. Simulator fOr Wind Farms Application (SOWFA) is an NREL high fidelity modeling tool that couples OpenFOAM CFD and NREL’s Aero-Elastic code Fatigue, Aerodynamics, Structures, and Turbulence (FAST). In BP1 the configuration was based on Hywind-3MW at 140 m water depth in the Gulf of Maine; however this study for Budget Period 2 (BP2) the configuration investigated is based on Hywind-6MW at 220 m water depth off the coast of Boston. The objectives were to perform two-turbines One-Way Coupling (OWC), three-turbines Two-Way Coupling (TWC), and to investigate wind power plant optimization.

99 GENERAL AND MISCELLANEOUS↗

Development and Bench-Scale Testing of a Novel Biphasic Solvent-Enabled Absorption Process for Post-Combustion Carbon Capture (Final Technical Report)

A new class of biphasic solvents was developed, and the concept of the enabled carbon dioxide (CO 2 ) absorption process was tested for post-combustion carbon capture in our previous lab-scale research. The primary goals of this project were to advance the development of the novel biphasic CO 2 absorption process (BiCAP) and validate its technical advantages by testing the integrated technology at a 40 kWe bench-scale with actual coal-derived flue gas in a power plant environment. The project was led by the University of Illinois at Urban-Champaign (UIUC), and Trimeric Corporation served as a sub-awardee providing support in basic design and techno-economic studies. To achieve the project goals and objectives, solvent management studies, process modeling and optimization, bench-scale equipment design, construction and testing, and technical, economic and environmental assessments have been conducted. The two top-performing biphasic solvents developed in our previous research were used in this project. Biphasic solvent emissions and control were investigated in the laboratory. The emissions of the biphasic solvents from the absorber were comparable to or lower than the reference 30 wt% monoethanolamine (MEA) solution, while they could be more effectively removed in the water wash column. Lab-scale testing of solvent degradation reclamation has revealed that vacuum distillation was feasible for biphasic solvent reclamation. Aspen Plus models were used to optimize the BiCAP, and a CO 2 stripping configuration introducing a secondary cold solvent feed to the stripper was identified to be the most energy efficient. A 40 kWe bench-scale, integrated BiCAP system was successfully designed, fabricated, and installed at the UIUC’s Abbott Power Plant. Parametric testing with synthetic flue gas has demonstrated that the two biphasic solvents required a more than 40% lower heat duty for CO 2 desorption as compared to the reference MEA tested on the same bench-scale skid. Slipstream testing with actual coal flue gas for a total of 31 days in two test campaigns has further demonstrated stable operation of the bench-scale skid. During the first campaign targeting 90% CO 2 removal, the heat duty averaged at 2,183 MJ/tonne of CO 2 captured and during the second campaign targeting 95% removal, the heat duty averaged at 2,450 MJ/tonne of CO 2 captured. A techno-economic analysis has revealed that for integration of the BiCAP into a 650-MWe pulverized coal-fired power plant, the parasitic power loss was reduced by ~20%, and the cost of CO 2 capture was reduced by ~21% ($36.3/tonne on a December 2018 dollar basis) compared to the U.S. Department of Energy (DOE)’s baseline Case B12B. As progression from this bench-scale development effort, a new project “Engineering-Scale Testing of the Biphasic Solvent Based CO 2 Absorption Capture Technology at a Covanta Waste-to-Energy Facility” was awarded by the DOE, launched in February 2023, to allow the team to further test the technology and demonstrate its technical and economic advantages at a pilot scale.

20 FOSSIL-FUELED POWER PLANTS↗