Four-Stage Multi-Physics Simulations to Assist Temperature Sensor Design for Industrial-Scale Coal-Fired Boiler

The growth of renewable energy sources presents a pressing challenge to the operation and maintenance of existing fossil fuel power plants, given that fossil fuel remains the predominant fuel source, responsible for over 60% of electricity generation in the United States. One of the main concerns within these fossil fuel power plants is the unpredictable failure of boiler tubes, resulting in emergency maintenance with significant economic and societal consequences. A reliable high-temperature sensor is necessary for in situ monitoring of boiler tubes and the safety of fossil fuel power plants. In this study, a comprehensive four-stage multi-physics computational framework is developed to assist the design, optimization installation, and operation of the high-temperature stainless-steel and quartz coaxial cable sensor (SSQ-CCS) for coal-fired boiler applications. With the consideration of various operation conditions, we predict the distributions of flue gas temperatures within coal-fired boilers, the temperature correlation between the boiler tube and SSQ-CCS, and the safety of SSQ-CCS. With the simulation-guided sensor installation plan, the newly designed SSQ-CCSs have been employed for field testing for more than 430 days. The computational framework developed in this work can guide the future operation of coal-fired plants and other power plants for the safety prediction of boiler operations.

42 ENGINEERING↗

Erosion-Corrosion Detection in Carbon Steel Pipe Loops using SRNLs Thickness and Mass Loss Measurement Coupons - 20464

Structural health of waste transfer infrastructure is of utmost importance to DOE and communities surrounding their active sites. A Fitness-for-Service (FFS) program for the Waste Transfer System has been implemented by the US Department of Energy (DOE) for the purposes of evaluating and quantifying the degradation of critical components. Currently, the method of approach is to section and evaluate pipelines that have been removed at end service. In order to augment data collection methods applied to making lifespan estimates of waste transfer system components, Florida International University (FIU) has been investigating new-technology based strategies for quantifying the rate of degradation. Present research considers the option of a coupon system installed on a section of pipe at points of interest that will provide easy access to high resolution measurements of erosion/corrosion rates during operation. Researchers at Savannah River National Laboratory (SRNL) have developed this novel solution for in situ erosion and corrosion measurements in many applicable locations such as tanks, pipes, ducts, and injection points. The coupons are approximately 12.7 mm (1/2 inch) in diameter and 25.4 mm (1 inch) in length and can be placed in the pipe sections using Swagelok compression fittings. The coupon design allows for monitoring of the total degradation resulting from corrosion and erosion. High-resolution Ultrasonic Thickness (UT) testing allows in-situ monitoring of both degradation mechanisms. When removed from the system mass loss resulting from corrosion and erosion may also be evaluated. Experimental testing at FIU implemented the SRNL coupon system in a 6.10 meter (20 foot) pipe loop system comprised of 50.8 mm (2 inch) and 76.2 mm (3 inch) pipe sections in order to replicate expected use cases at the sites. Operational conditions were emulated by pumping abrasive materials through the pipeline at full capacity and collecting measurements from the SRNL coupons. Initial testing was conducted by circulating water followed by a mixture of sand and water for uniform wear rates. Thickness changes and mass loss were measured, and the surface exposed to the process fluid was observed for visual evidence of characteristic wear patterns resulting from an erosive environment. The test matrix consisted of several hours of operation and using fine, medium and coarse grain sands. Test results were analyzed to check for all three parameters (mass loss/gain, thickness change and surface patters) which could provide estimates of the remaining useful life of the pipe sections. Thus, the research presents the findings of this evaluation of the SRNL coupons as a means for conducting high accuracy, cost effective in-situ analysis of pipeline and waste transfer systems for erosion and corrosion susceptibility. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Quantifying Moss Response to Metal Contaminant Exposure Using Laser-Induced Fluorescence

Tracing sources of contamination, including potentially toxic elements (PTEs), has historically been achieved through sampling and analysis of soil or biota, which are labor-intensive, costly, and destructive methods. Thus, availability of a non-destructive in situ remote sensing method for monitoring metals deposited in biota is of great interest. Laser-induced fluorescence (LIF) is an emerging spectroscopic and imaging technique that documents changes in molecular energy level in plants as a biological response to metal contamination. For a proof-of-concept study and preliminary experiment, moss was selected for experimentation due to its long history of use in tracing atmospheric deposition of PTEs. Consecutive treatments of copper chloride (CuCl2) were administered to three moss samples, simulating wet deposition every 48 h over 10 days until reaching cumulative Cu concentrations of 2.690 to 8.075 μmol/cm2. While these Cu amounts are above environmentally relevant concentrations, they allowed the best conditions for testing and fine tuning of the imaging and data processing protocols presented in this paper. Moss fluorescence was induced using both 532 nm green and 355 nm UV lasers. A CMOS camera captured images of the LIF response, and red–green–blue (RGB) decimal code values were extracted for each pixel in the images, and pixel densities of color channels from treated and untreated moss samples were compared. Results show a shift towards lower color decimal codes corresponding to increased Cu concentration. We developed and contrasted multiple quantitative analyses of color distributions and demonstrated that LIF shows great promise for remote sensing of Cu accumulation in moss at μmol/cm2 levels. Though currently, the method would be limited to highly toxic sites, it illustrates the possibility and provides a framework for development of higher-sensitivity methods to detect nmol/cm2 that are viable for urban contamination level monitoring.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Thiol redox switches regulate the oligomeric state of cyanobacterial Rre1, RpaA and RpaB response regulators

Cyanobacteria employ two‐component sensor‐response regulator systems to monitor and respond to environmental challenges. The response regulators RpaA, RpaB, Rre1 and RppA are integral to circadian clock function and abiotic stress acclimation in cyanobacteria. RpaA, RpaB and Rre1 are known to interact with ferredoxin or thioredoxin, raising the possibility of their thiol regulation. Here, we report that Synechocystis sp. PCC 6803 Rre1, RpaA and RpaB exist as higher‐order oligomers under oxidising conditions and that reduced thioredoxin A converts them to monomers. We further show that these response regulators contain redox‐responsive cysteine residues with an E m7 around −300 mV. These findings suggest a direct thiol modulation of the activity of these response regulators, independent of their cognate sensor kinases.

14 SOLAR ENERGY↗

Using dorsal surface for individual identification of dairy calves through 3D deep learning algorithms

Advances in machine learning techniques have allowed the development of computer vision systems (CVS) that can accurately predict several phenotypes of interest for livestock operations. In this context, 3D images taken from a top-down view are particularly useful for estimating body condition score, growth development, and body biometrics in cattle. Frequently, such CVS rely on identification (ID) systems, such as electronic tags, as a way to match animal ID and the predicted phenotype. However, the same 3D images used to predict body weight and other animal biometrics could be adopted for animal recognition as well. Such alternative would optimize CVS to recognize animal ID and monitor growth development simultaneously while leveraging the same hardware infrastructure. Furthermore, this strategy could be used to recognize animals with similar color patterns. Nonetheless, growing animals are continuously changing body shape, which could limit its use as an invariant feature for pattern recognition. Thus, the objectives of this study were: (1) to compare algorithms for different 3D object representations to identify individual animals; and (2) to evaluate how short-term changes in body shape due to animal growth affect the predictive performance of these algorithms. For objective 1, the algorithms were trained (n = 4,558) and tested (n = 1,139) using images from 38 Holstein calves. For objective 2, we designed three different experiments using images (n = 2,347) from five Holstein calves taken over six weeks during their growing period, always training and testing on different weeks. Each experiment evaluated how changing a different parameter of the image capturing procedure affected the predictive ability of the trained algorithms. In the first experiment, we varied the total number of images per animal in the training set; in the second experiment, we varied the number of weeks while keeping a fixed number of images in the training set; and in the third experiment, we skipped weeks between images in the training and test sets. The F 1 score for objective (1) was up to 0.804 when testing with the last frames of each video, and up to 0.959 when using random frames for testing. For objective (2), the F 1 score was up to 0.947 for the first experiment when using 130 images per animal; up to 0.979 for the second experiment when using all five weeks; and up to 0.917 when not skipping weeks between training and testing. In conclusion, these results show that deep learning algorithms can be used to identify individual animals through their dorsal area 3D surfaces, and, from our experiments using calves in their growing period, that they are robust enough to account for changes in body shape and size, making them a promising tool for animal recognition during growth.

3D neural networks↗

Advancing specialized biofoundries via automated adaptive laboratory evolution

Adaptive laboratory evolution (ALE) is a powerful strategy for improving microbial phenotypes by harnessing natural selection under defined environmental conditions. Through applying selection regimes, beneficial mutations accumulate, enabling the generation of strains with enhanced properties. However, conventional ALE is labor-intensive and difficult to scale, limiting reproducibility and broader discovery of evolutionary principles. Recent advances in robotics, automation, and computational infrastructure are transforming ALE into a scalable, data-rich experimental paradigm. Automated platforms enable standardized and complex protocols, real-time monitoring, and highly parallel evolution campaigns, improving consistency while generating longitudinal datasets that reveal convergent adaptive mechanisms. Here, we discuss the role of specialized biofoundries in advancing automated ALE and enabling large-scale evolutionary engineering. We review major automated ALE formats and outline key design principles for effective ALE biofoundries, highlighting how automated ALE can support autonomous experimentation and AI-guided strain engineering.

59 BASIC BIOLOGICAL SCIENCES↗

Computational Fluid Dynamics Simulations to Assess Spatial Variability and Optimal Ventilation Scenarios for Biological Laboratory Exposures

A significant amount of uncertainty exists regarding potential human exposure to laboratory biomaterials and organisms in Biosafety Level 2 (BSL-2) research laboratories. Computational fluid dynamics (CFD) modeling is proposed as a way to better understand potential impacts of different combinations of biomaterials, laboratory manipulations, and exposure routes on risks to laboratory workers. Here, in this study, we use CFD models to simulate airborne concentrations of contaminants in an actual BSL-2 laboratory under different configurations. Results show that ventilation configuration, sampling location, and contaminant source location can significantly impact airborne concentrations and exposures. Depending on the source location and airflow patterns, the transient and time-integrated concentrations varied by several orders of magnitude. Contaminant plumes from sources located near a return vent (or exhaust like a fume hood or ventilated biosafety cabinet) are likely to be more contained than sources that are further from the exhaust. Having a direct flow between the source and the exhaust (through-flow condition) may reduce potential exposures to individuals outside the air flow path. Designing a BSL-2 room with ventilation and airflow patterns that maximize through-flow conditions to the return/exhaust vents and minimize dispersion and mixing throughout the room is, therefore, recommended. CFD simulations can also be used to assist in characterizing the impacts of supply and return vent locations, room layout, and source locations on spatial and temporal contaminant concentrations. In addition, proper placement of particle sensors can also be informed by CFD simulations to provide additional characterization and monitoring of potential exposures in BSL-2 facilities.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Initial Radiation of Nuclear Power Plant Components (CRADA NFE-17-06892 Final Report)

As advanced reactor concepts are developed, instrumentation and control (I&C) cables and sensors will play a significant role in assuring their operation is well understood, and safety-related process information can be collected reliably over the course of their design life. As a first step to develop acceptance criteria and define the limits of currently available nuclear I&C cable and sensor technology, a collaboration between Oak Ridge National Laboratory and Analysis and Measurement Services (AMS) Corporation was initiated under the Gateway for Accelerated Innovation in Nuclear (GAIN) Program. This collaborative effort focused on providing technical information related to the combined thermal and radiation aging of nuclear power plant (NPP) cables, companion NPP cable insulation samples, and two prototype temperature and two pressure sensors. This work was carried out using the instrumented gamma irradiation system that is part of the High Flux Isotope Reactor Gamma Irradiation Facility (HFIR GIF). This system provided the opportunity for the condition of the prototype sensors to be tracked during the irradiation in order to determine their functional limits with greater granularity when compared to a simple irradiation insertion at the HFIRGIF. Experimental assemblies for sensor irradiation were successfully completed, and sensor irradiation to accumulated dose of 3000 kGy at a rate of approximately 6 kGy/hr was carried out. Two prototype temperature assemblies were continuously monitored during exposure to 3000 kGy and found to have no observable degradation from the irradiation. Two pressure sensors were first irradiated to 1000 kGy. At which point, one of the sensors was found to operate normally; however, a second sensor failed the operability test. The operable pressure sensor output was then continuously monitored from 1000 kGy to 3000 kGy. The sensor output exhibited steady trendable drift versus the accumulated radiation dose. At the conclusion of the irradiation, the four test sensors were released for laboratory calibration checks. The calibration check of the temperature sensors found no significant change after irradiation compared to baseline measurements before irradiation; however, both pressure sensors failed the post-test calibration checks and both sensors were not functioning properly. These results will help inform sensor manufacturers and I&C design engineers of potential limitations of these types of sensors for use in high radiation environments associated with the compact configuration of new Small Modular Reactors (SMRs) such as NuScale’s reactor power module. Irradiations on NPP cables and companion samples were not completed due to programmatic delays, however a path forward that was based on lessons learned from this project was defined to accommodate future, comparable instrumented gamma irradiations at the HFIR GIF.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Nuclear Material Control & Accounting for Pebble Bed Reactors (FY 2023 Summary Report)

This report discusses the work done under the US Department of Energy NE-5 Advanced Reactor Safeguards and Security Program during FY 2023. It provides a summary of material control and accounting (MC&A) for pebble bed reactors (PBRs) and addresses some of the main challenges with current PBR MC&A approaches that will inform safeguards and security by design efforts. The efforts to date have focused on tristructural isotropic (TRISO) pebble fuel material accounting and control including working with partners in industry, loss and production of nuclear material as part of reactor operations, burnup modeling and measurements, uncertainty quantifications for such modeling and measurements, statistical approaches needed, and measurement methods. The unique fuel management and utilization in a PBR, where the fuel in spherical form is introduced and circulates through the reactor, poses special challenges for MC&A. This contrasts with traditional water-cooled reactors in which the fuel is contained in large assemblies and can be easily identified and counted. Even online fueled reactors, such as the CANDU reactors (none of which operate in the United States), are significantly different because the fuel is still contained in relatively large assemblies, is uniquely identified, and the number of assemblies that pass through the core on an annual basis is much fewer than the hundreds of thousands that circulate in a PBR, none of which are uniquely identified. Additionally, the nature of the TRISO fuel results in very low heavy metal loading with each pebble containing less than 10 g of uranium and on the order of less than 1 g of fissile material. This low fuel density and the robustness of the TRISO particles are major features of the TRISO fuel from a safety basis as each TRISO particle and pebble acts as a containment for the nuclear material and fission products during normal and accident conditions. This also results in very low plutonium loading per pebble during normal operations, which is on the order of 0.1 g at full burnup. A major feature of PBRs is that they will allow for significantly higher burnup, on the order of 160 GWd/THM compared to the burnup of traditional LWRs, which is on the order of 45 GWd/THM. This is achieved by monitoring the pebbles as they circulate through the reactor and allowing them to be reintroduced into the core until the desired burnup is achieved and they are removed from the reactor and enter the spent fuel storage areas.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Radiolytic Gas Generation and Pressure Buildup in a Closed System Containing Mo-99 Solution

This study measured radiolytic gas generation and pressure buildup in a sealed stainless-steel system containing alkaline Mo-99 solution with added sodium nitrate as a hydrogen suppressant. In each of two experiments, approximately 200 Ci of Mo-99 solution was transferred into a closed experimental vessel inside a hot cell, isolated, and monitored for pressure rise caused by gas generation during radioactive decay. After pressure buildup, headspace gas samples were collected and analyzed by mass spectrometry to determine hydrogen and oxygen concentrations. The purpose was to quantify the magnitude of pressure buildup in a closed system and to characterize the gas composition produced by radiolysis of the Mo-99 target solution under representative handling and storage conditions. The two experiments used similar total Mo-99 activity but differed in solution volume, headspace volume, and leak integrity. In the first experiment, 197.5 Ci of Mo-99 in 16.92 mL of solution was loaded into a vessel with a 31.1-mL headspace; a small leak was later identified, and the measured peak pressure of 46 psig was extrapolated to about 70 psig in the absence of leakage. The headspace gas from this experiment contained about 21.4% H2 and 63.4% O2, but the composition was influenced by preferential hydrogen loss through the leak. In the second experiment, 193 Ci of Mo-99 in 5.41 mL of solution with 0.46 g NaNO3 was loaded into a vessel with a larger 42.61 mL headspace, and no detectable leak was observed. This experiment reached a peak pressure of 38 psig, and the measured gas composition was approximately 28.2% H2 and 51.5% O2. Because the second experiment was leak-free, it is considered the more reliable indicator of the true pressure buildup and intrinsic radiolytic gas composition of the Mo-99 solution.

Chemerisov, Sergey D.↗

RuBisCO activity assays: a simplified biochemical redox approach for in vitro quantification and an RNA sensor approach for in vivo monitoring

Abstract Background Ribulose-1,5-bisphosphate carboxylase/oxygenase (RuBisCO) is the most abundant soluble protein in nature. Extensive studies have been conducted for improving its activity in photosynthesis through approaches like protein engineering. Concurrently, multiple biochemical and radiolabeling assays have been developed for determining its activity. Although these existing assays yield reliable results, they require addition of multiple external components, rendering them less convenient and expensive. Therefore, in this study, we have developed two relatively cheaper, convenient, and easily reproducible assays for quantitative and qualitative estimation of RuBisCO activity. Results We simplified a contemporary NADH based spectrophotometric RuBisCO assay by using cyanobacterial cell lysate as the source for Calvin cycle enzymes. We analyzed the influence of inorganic carbon substrates, CO 2 and NaHCO 3 , and varying protein concentrations on RuBisCO activity. Ribulose-1,5-bisphosphate (RuBP) consumption rates for the cultures grown under 5% CO 2 were 5–7 times higher than the ones grown with 20 mM NaHCO 3 , at different protein concentrations. The difference could be due to the impaired activity of carbonic anhydrase in the cell lysate, which is required for the conversion of HCO 3 − to CO 2 . The highest RuBisCO activity of 2.13 nmol of NAD + / µg of Chl-a/ min was observed with 50 µg of protein and 5% CO 2 . Additionally, we developed a novel RNA-sensor based fluorescence assay that is based on the principle of tracking the kinetics of ATP hydrolysis to ADP during the conversion of 3-phosphoglycerate (3-PG) to 1,3-bisphosphoglycerate (1,3-BPG) in the Calvin cycle. Under in vitro conditions, the fluorometric assay exhibited ~ 3.4-fold slower reaction rate (0.37 min −1 ) than the biochemical assay when using 5% CO 2 . We also confirmed the in vivo application of this assay, where increase in the fluorescence was observed with the recombinant strain of Synechocystis sp. PCC 6803 (SSL142) expressing the ADP-specific RNA sensor, compared to the WT. In addition, SSL142 exhibited three-fold higher fluorescence when supplemented with 20 mM NaHCO 3 as compared to the cells that were grown without NaHCO 3 supplementation. Conclusions Overall, we have developed a simplified biochemical assay for monitoring RuBisCO activity and demonstrated that it can provide reliable results as compared to the prior literature. Furthermore, the biochemical assay using 5% CO 2 (100% relative activity) provided faster RuBP consumption rate compared to the biochemical assay utilizing 20 mM NaHCO 3 (30.70% relative activity) and the in vitro fluorometric assay using 5% CO 2 (29.64% relative activity). Therefore, the absorbance-based biochemical assay using 5% CO 2 or higher would be suitable for in vitro quantification of the RuBisCO activity. On the other hand, the RNA-sensor based in vivo fluorometric assay can be applied for qualitative analysis and be used for high-throughput screening of RuBisCO variants. As RuBisCO is an enzyme shared amongst all the photoautotrophs, the assays developed in this study can easily be extended for analyzing the RuBisCO activities even in microalgae and higher plants.

59 BASIC BIOLOGICAL SCIENCES↗

On-demand fabrication of piezoelectric sensors for in-space structural health monitoring

Abstract Inflatable structures, promising for future deep space exploration missions, are vulnerable to damage from micrometeoroid and orbital debris impacts. Polyvinylidene fluoride-trifluoroethylene (PVDF-trFE) is a flexible, biocompatible, and chemical-resistant material capable of detecting impact forces due to its piezoelectric properties. This study used a state-of-the-art material extrusion system that has been validated for in-space manufacturing, to facilitate fast-prototyping of consistent and uniform PVDF-trFE films. By systematically investigating ink synthesis, printer settings, and post-processing conditions, this research established a comprehensive understanding of the process-structure-property relationship of printed PVDF-trFE. Consequently, this study consistently achieved the printing of PVDF-trFE films with a thickness of around 40 µ m, accompanied by an impressive piezoelectric coefficient of up to 25 pC N −1 . Additionally, an all-printed dynamic force sensor, featuring a sensitivity of 1.18 V N −1 , was produced by mix printing commercial electrically-conductive silver inks with the customized PVDF-trFE inks. This pioneering on-demand fabrication technique for PVDF-trFE films empowers future astronauts to design and manufacture piezoelectric sensors while in space, thereby significantly enhancing the affordability and sustainability of deep space exploration missions.

Instruments & Instrumentation↗

Multi-Gas Sensors for Enhanced Reliability of SOFC Operation

GE Research, in partnership with SUNY Polytechnic Institute (SUNY Poly), designed, built, and tested gas sensors for in situ monitoring of H 2 and CO anode tail gases produced with on-site steam reforming in solid oxide fuel cell (SOFC) systems. The knowledge of the H 2 /CO ratio of these anode tail gases should allow accurate determination and control of the efficiency of the reforming process in the SOFC system and should deliver a lower operating cost for SOFC customers. The project objectives were to achieve multi-gas monitoring capability with a single multivariable sensor, and to sustain this performance in the presence of gaseous interferences and a potential poison for the sensor. The duration of the project was 24 months with the project structure that included three technical tasks such as (1) development of design rules of photonic nanostructures for H 2 and CO gas detection, (2) laboratory validation of photonic nanostructures for selective H 2 and CO gas detection, and (3) validation of photonic nanostructures for initial stability and poison-resistance against H 2 S. To build multivariable sensors for selective H 2 and CO gas detection in the presence of interferences, we expanded our earlier knowledge of multi-gas sensors into new fabrication and functionalization methodologies as well as into new methodologies for the spectral data analysis of multi-gas responses. We have advanced our design rules of the three-dimensional (3D) photonic nanostructures that allowed detection of H 2 and CO at high temperatures as individual gases and as their mixtures and rejection of interferences such as CO 2 , H 2 O, CH 4 , and other hydrocarbons for SOFC applications. Our advanced design rules should be attractive for building the new generation of cost-effective industrial sensors. Stability and poison resistance of our 3D photonic nanostructures was tested in the laboratory conditions. While initially we utilized conventional machine learning data analysis tools, we have found that they were unable to correct for the sensor drift. Thus, we have implemented new methods of machine learning for the analysis of our spectral data. These learnings pave the way to move the future studies into advanced testing of effects of interferences, aging and field tests. In future, our work will continue to advance our sensing designs to operate in conditions with known and unknown interferences by implementing nanostructures with enhanced spectral diversity of responses to gaseous species of interest and interferences. Our systematic reduction of technical risks in this completed project and in future studies will ensure transition of this sensing technology to commercialization.

03 NATURAL GAS↗

Reaction Mechanism of the Synthesis of a Disordered Rock Salt Cathode Material

Li-rich disordered rock salt (DRX) materials have recently emerged as a class of promising cathode materials for cobalt- and nickel-free Li-ion batteries that can achieve a high energy density and high electrochemical storage capacity. Here, the synthesis conditions of DRX were found to have a significant impact on the electrochemical performance of the final product formed and hence need to be carefully controlled. To date, the formation pathway of DRX materials has remained largely unexplored. In this work, the phase evolution of a DRX material, Li 1.1 Mn 0.8 Ti 0.1 O 1.9 F 0.1 (LMTF1811), during solid-state synthesis, was monitored using in situ synchrotron X-ray diffraction (sXRD). We have observed several crystalline intermediates formed during the synthesis process before the full formation of DRX. Ex situ X- ray absorption spectroscopy (XAS) was used to assess the local structure and charge states of the transition metals. F K-edge XAS collected from the final product LMTF1811 shows that the degree of F incorporation into the DRX phase is low.

Diffraction↗

Using Ensemble Data Assimilation to Estimate Transient Hydrologic Exchange Flow Under Highly Dynamic Flow Conditions

Abstract Quantifying dynamic hydrologic exchange flows (HEFs) within river corridors that experience high‐frequency flow variations caused by dam regulations is important for understanding the biogeochemical processes at the river water and groundwater interfaces. Heat has been widely used as a tracer to infer steady‐state flow velocities through analytical solutions of heat transport defined by the diurnal temperature signals. Under sub‐daily dynamic flow conditions, however, such analytical solutions are not applicable due to the violation of their fundamental assumptions. In this study, we developed a data assimilation‐based approach to estimate the sub‐daily flux under highly dynamic flow conditions using multi‐depth temperature observations at a 5‐min resolution. If the hydraulic gradient is measured, Darcy's law was used to calculate the flux with permeability estimated from temperature responses below the riverbed. Otherwise, flux was estimated directly by assimilating multi‐depth temperature data at 1‐ or 2‐hr time intervals assuming one‐dimensional flow and heat transport governing equation. By comparing estimated fluxes with model‐generated synthetic truth, we demonstrated that both schemes have robust performance in estimating fluxes under highly dynamic flow conditions. This data assimilation‐based flux estimation method was able to capture the vertical sub‐daily fluxes using multi‐depth high‐resolution temperature data alone, even in the presence of multi‐dimensional flow. This approach has been successfully applied to real field temperature data collected at the Hanford site, which experiences highly dynamic HEFs. Our study shows the promise of adopting distributed 1‐D temperature monitoring to capture spatial and temporal exchange dynamics in river corridors at a watershed scale or beyond.

54 ENVIRONMENTAL SCIENCES↗

Radiation-induced alteration of apatite on the surface of Mars: first in situ observations with SuperCam Raman onboard Perseverance

Abstract Planetary exploration relies considerably on mineral characterization to advance our understanding of the solar system, the planets and their evolution. Thus, we must understand past and present processes that can alter materials exposed on the surface, affecting space mission data. Here, we analyze the first dataset monitoring the evolution of a known mineral target in situ on the Martian surface, brought there as a SuperCam calibration target onboard the Perseverance rover. We used Raman spectroscopy to monitor the crystalline state of a synthetic apatite sample over the first 950 Martian days (sols) of the Mars2020 mission. We note significant variations in the Raman spectra acquired on this target, specifically a decrease in the relative contribution of the Raman signal to the total signal. These observations are consistent with the results of a UV-irradiation test performed in the laboratory under conditions mimicking ambient Martian conditions. We conclude that the observed evolution reflects an alteration of the material, specifically the creation of electronic defects, due to its exposure to the Martian environment and, in particular, UV irradiation. This ongoing process of alteration of the Martian surface needs to be taken into account for mineralogical space mission data analysis.

Science & Technology - Other Topics↗

Radiance-based NIR v as a proxy for GPP of corn and soybean

Substantial uncertainty exists in daily and sub-daily gross primary production (GPP) estimation, which dampens accurate monitoring of the global carbon cycle. Here we find that near-infrared radiance of vegetation (NIR v,Rad ), defined as the product of observed NIR radiance and normalized difference vegetation index (NDVI), can accurately estimate corn and soybean GPP at daily and half-hourly time scales, benchmarked with multi-year tower-based GPP at three sites with different environmental and irrigation conditions. Overall, NIR v,Rad explains 84% and 78% variations of half-hourly GPP for corn and soybean, respectively, outperforming NIR reflectance of vegetation (NIR v,Ref ), enhanced vegetation index (EVI), and far-red solar-induced fluorescence (SIF760). The strong linear relationship between NIR v,Rad and absorbed photosynthetically active radiation by green leaves (APAR green ), and that between APAR green and GPP, explain the good NIR v,Rad -GPP relationship. The NIR v,Rad -GPP relationship is robust and consistent across sites. The scalability and simplicity of NIR v,Rad indicate a great potential to estimate daily or sub-daily GPP from high-resolution and/or long-term satellite remote sensing data.

54 ENVIRONMENTAL SCIENCES↗

Additively Manufactured Strain Sensing for Nuclear Reactor Applications

Real-time monitoring of materials in harsh environments is a crucial technique towards reducing innovation time in nuclear systems. The successful measurement of real time, in-situ strain measurements during nuclear reactor operation requires innovative sensing solutions, including novel sensing strategies as well as advanced sensor design, manufacturing, and materials selection. In this paper, we will discuss two primary strategies for in-situ strain measurement strategies: additively manufactured (AM) capacitive strain gauges (CSGs) and digital image correlation (DIC). Current commercial strain gauges have limited applications in reactors due to the harsh operating conditions and non-trivial attachment strategies (i.e., welding, epoxy-adhesive) that can affect both the sensing performance and the underlying substrate under testing. AM CSGs are a viable solution as they have a low profile, low hysteresis, and wireless sensing integration capabilities that will enhance nuclear sensing technologies. In this work, the mechanical and thermal performance of the AM CSGs were tested up to 300 °C using ASTM standardized testing procedures to simulate the temperatures found in existing light water reactors. The AM CSGs had a similar performance across multiple samples which correlates to analytical models. This work leads towards the development of CSGs designed for higher temperatures and additional environmental factors found in Generation-IV reactors. Non-contact sensors, such as DIC, offer a less destructive way to measure deformation of materials when compared to alternative methods of in-situ strain determination, such as weldable strain gauges. However, DIC requires high contrast surfaces, which often relies on the implementation of artificial patterns. Using traditional splatter techniques to fabricate these patterns have limitations, including poor surface adhesion and reproducibility. In this work, AM fabrication techniques were implemented to avoid such limitations. Accordingly, aerosol jet printing (AJP) was used to print small scale periodic patterns of silver on stainless steel and aluminum tensile specimens. DIC was employed to monitor strain (up to 1100 µe) during temperature cycling from 23-600 °C. The results validated the use of AJP to better control pattern parameters for small fields of view applications at high temperatures.