A direct contact cooler design for simultaneously recovering latent heat and capturing SO x and NO x from pressurized flue gas

Integrated SO x and NO x removal technology using a direct contact cooler is a promising alternative for cleaning coal combustion flue gas, especially for pressurized combustion systems. Past investigations of integrated SO x and NO x removal have been limited to low-temperature processes, where the flue gas has been cooled upstream of the removal unit, and the moisture in the flue gas has been condensed out. Here this work presents a novel design that recovers the flue gas heat while simultaneously removing SO x and NO x in a single reactive-absorption column – direct contact cooler. A validated model was used to evaluate different direct contact cooler designs. Modeling results suggested that a counter-current column with a single water inlet can scrub 83% of the NO x and 96.5% of the SO x in 115 s, while an optimized design with multiple water inlets enhances the scrubbing of NO x by 9 percentage points and SO x by 3.5 percentage points, due to a 34% increase in residence time. It is also observed that the liquid-phase reaction between absorbed SO x and NO x plays a significant role in the removal of SO 2 from the flue gas for high-temperature scrubbing compared with low-temperature scrubbing. The design reinforces the potential of high-temperature SO x -NO x removal and heat recovery and suggests a means of reducing capital costs for such columns.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

THESEUS: A techno-economic design, integration and downselection framework for energy storage

Optimal selection of energy storage technologies is critical to ensure reliable integration of intermittent and often uncertain renewable energy in electricity grids. The consideration of a diverse set of energy storage technologies is required for a more sustainable deployment of energy storage. We present THESEUS (TecHno-Economic framework for Systematic Energy storage Utilization and downSelection), which is a comprehensive framework for the optimal selection, design and operation of energy storage systems. THESEUS includes rigorous models of major energy storage technologies at different maturity levels, such as thermal storage using phase-change materials or molten salt, cryogenic storage, mechanical storage in the form of compressed air and pumped hydro storage, chemical storage using hydrogen, and electrochemical storage in the form of lithium-ion, sodium sulfur and vanadium flow batteries. An illustrative case study on state-wide prospective energy storage shows that storage integration with fossil power plants could reduce the cost of meeting the grid energy demand by 20%, with mechanical storage as the best suited technology. Although high-temperature thermal storage has low storage efficiency, it is optimal for integration with renewable energy plants. In addition, Li-ion batteries are optimal for high ramping but low storage duration requirements. Furthermore, such insights can enable the deployment of both existing and emerging energy storage technologies to facilitate a smooth transition to a clean energy future.

25 ENERGY STORAGE↗

Interactions of Wind Energy Project Siting, Wind Resource Potential, and the Evolution of the U.S. Power System

The interactions of wind energy project siting, resource potential, and power system evolution are critical to understand given interest in high renewable energy systems, particularly as wind costs have fallen and grid operators implement solutions to manage variable generation. This study applies an integrative approach that combines spatially-explicit resource potential analysis with high spatial resolution U.S. electricity system modeling. Multiple wind supply curves, representing variations in siting regimes that account for interactions with built infrastructure, regulatory, physical, and social land use factors, are evaluated to determine how siting could influence prospective wind development. Different siting regimes lead to variations in future wind capacity, with the greatest impacts observed under scenarios with high demand for clean energy. With the tightest emissions limit modeled, 2050 onshore wind capacity varied by +7% (49 GW) in the least-restrictive siting regime to a decrease of 37% (270 GW) under the most-constrained case. More-stringent siting restrictions lead to higher electricity prices and emissions that should be weighed with local impacts. Under restrictive siting regimes, wind deployment is also sensitive to transmission availability and wind plant design. Overall, the findings highlight the importance of local land use considerations in regional and national power system planning.

17 WIND ENERGY↗

Land use and turbine technology influences on wind potential in the United States

As clean energy ambitions have expanded, critically evaluating renewable energy supply has become increasingly important to the energy research community and stakeholders. This study examines the onshore wind resource potential for the conterminous United States and its sensitivity to siting constraints and turbine technology innovation. We compile localized regulatory information and use high-resolution data to present multiple siting regimes covering relatively constrained to unconstrained potentials. Our efforts reveal high sensitivity to these variables and sizable uncertainty in the overall wind energy resource potential. Specifically, we find that siting constraints may shift the total capacity available to commercial wind energy by 2.3–15.1 TW. Furthermore, our results illustrate that technology advancement could require larger setbacks from buildings and infrastructure, reducing the total available capacity potential by 20% relative to estimates using current technology, but that this reduction is largely offset by increased generation such that the net effect on generation is 1%. The observed sensitivity to and uncertainty resulting from the variables we analyze suggest there is value in continued study and development of increasingly sophisticated approaches to characterizing wind resource potential.

14 SOLAR ENERGY↗

Experimental flow-through a single fracture with monolayer proppant at reservoir conditions: A case study on Caney Shale, Southwest Oklahoma, USA

Global energy systems are undergoing a crucial transition to clean energy sources, thereby moving away from fossil-fuel based energy with the ultimate aim of reducing carbon dioxide emissions. It is essential to continue to advance in exploring and developing shale gas resources as this will underpin the global supply of natural gas that is needed to support the energy transition. The challenge hereby is that the slow fluid flow of the shale matrix due to its very low permeability requires large-scale volume fracturing to produce a conductive fracture network that enhances the connectivity between the shale formation and the wellbore. This work examines the influence of a thin proppant layer on a single fracture using a flow-through experiment, and also explores whether proppant embedment in the Caney shale is affected by the rock mineralogy, surface roughness, fluids, confining stress, time, temperature and bedding. The experiment was conducted for a duration of nine days (216 h), experimental temperature was varied from ambient temperature to reservoir temperature of 125 °C (257 °F) and confining stress was varied from 367 psi (2.53MPa) to a maximum of 4011.82 psi (27.66 MPa). Here, we find that the conductivity of the fracture is primarily influenced by the layer of proppant used, surface roughness, mineralogy, fluids, temperature and closure stress.

Caney shale↗

Sequence2Self: Self-supervised image sequence denoising of pixel-level spray breakup morphology

Optical imaging of fast and transient phenomena such as the turbulent breakup of liquid sprays exhibit low signal-to-noise ratios due to the limited illumination intensity relative to the short exposure time. Image denoising is required to facilitate physical studies over these data but is challenging due to the absence of clean ground-truths and the stringency of the denoising task (e.g., strong and complex noise, limited resolution, preserving physical fidelity), preventing supervised and existing un-/self-supervised deep learning methods. To this end, Sequence2Self (Seq2S) is proposed, an extension of Self2Self (S2S) to image sequences that leverages both the signal’s spatial and temporal correlation. Seq2S is demonstrated on time-resolved x-ray phase contrast imaging of liquid jet fuel sprays in a gas turbine combustor, which possesses all of challenges detailed above. Experiments are conducted across four fuels with different breakup morphology using various state-of-the-art methods. Overall, many of the methods failed and Seq2S was most successful: (1) Accurate spray structures were reconstructed with consistent evolution across frames void of artifacts. (2) The performance was robust, invariant to the hyperparameter choice. (3) Computational time is short and can be made eligible for real-time denoising. In particular, the images denoised by Seq2S showed spray droplet diameter distributions with near-zero Kullback–Leibler divergence (0.01 ± 0.01) to a cleaner reference, whereas the second best method yielded 0.06 ± 0.03. In conclusion, this suggests that Seq2S can be reliably used prior to subsequent quantitative spray analyses as it retains (if not, improves) the statistical physical properties of the data.

97 MATHEMATICS AND COMPUTING↗

Changing bioavailability of per- and polyfluoroalkyl substances ($\mathrm{PFAS}$) to plant in biosolids amended soil through stabilization or mobilization

Biosolids containing per- and polyfluoroalkyl substances (PFAS) could contaminate the receiving environments once they are land applied. In this report, we evaluated the feasibility of controlling the bioavailability of PFAS in biosolids to timothy-grass through stabilization or mobilization approaches. Stabilization was accomplished by adding a sorbent (i.e. granular activated carbon (GAC), RemBind, biochar) to biosolids, while mobilization was achieved by adding a surfactant, sodium dodecyl sulphate (SDS), to biosolids. The results showed that the ΣPFAS concentration in grass shoots grown in biosolids amended soil treated by GAC or RemBind at 2% was only 2.77% and 3.35% of the ΣPFAS concentration detected in shoots grown in biosolids amended soil without a sorbent, respectively, indicating the effectiveness of GAC and RemBind for stabilizing PFAS and reduce their bioavailability. On the other hand, mobilization by adding SDS to biosolids at a dose range of 10–100 mg/kg significantly increased the plant uptake of ΣPFAS by 15.48%–108.57%. Thus, mobilization by adding SDS could be a valuable approach for enhancing the PFAS removal if phytoremediation is applied. Moreover, higher rate of PFAS uptake took place after grass cutting was observed in this study. Thus, proper mowing and regrowth of timothy-grass could lead to efficient and cost-effective removal of PFAS from biosolids amended soil through phytoremediation and leave the site clean to be used for other purposes.

54 ENVIRONMENTAL SCIENCES↗

Incidence of chronic respiratory conditions among oil spill responders: Five years of follow-up in the Deepwater Horizon Oil Spill Coast Guard Cohort study

Background: Over ten years after the Deepwater Horizon (DWH) oil spill, our understanding of long term respiratory health risks associated with oil spill response exposures is limited. Here we conducted a prospective analysis in a cohort of U.S. Coast Guard personnel with universal military healthcare. Methods: For all active duty cohort members (N = 45,193) in the DWH Oil Spill Coast Guard Cohort Study we obtained medical encounter data from October 01, 2007 to September 30, 2015 (i.e., ~2.5 years pre-spill; ~5.5 years post-spill). We used Cox Proportional Hazards regressions to calculate adjusted hazard ratios (aHR), comparing risks for incident respiratory conditions/symptoms (2010–2015) for: responders vs. non-responders; responders reporting crude oil exposure, any inhalation of crude oil vapors, and being in the vicinity of burning crude oil versus responders without those exposures. We also evaluated self-reported crude oil and oil dispersant exposures, combined. Within-responder comparisons were adjusted for age, sex, and smoking. Results: While elevated aHRs for responder/non-responder comparisons were generally weak, within-responder comparisons showed stronger risks with exposure to crude oil. Notably, for responders reporting exposure to crude oil via inhalation, there were elevated risks for all sinusitis (aHR = 1.48; 95%CI, 1.06–2.06), unspecified chronic sinusitis (aHR = 1.55; 95%CI, 1.08–2.22), chronic obstructive pulmonary disease (COPD) and other allied conditions (aHR = 1.43; 95%CI, 1.00–2.06), and dyspnea and respiratory abnormalities (aHR = 1.29; 95%CI, 1.00–1.67); there was a suggestion of elevated risk for diseases classified as asthma and reactive airway diseases (aHR = 1.18; 95%CI, 0.98–1.41), including the specific condition, asthma (aHR = 1.35; 95%CI, 0.80–2.27), the symptom, shortness of breath (aHR = 1.50; 95%CI, 0.89–2.54), and the overall classification of chronic respiratory conditions (aHR = 1.18; 95%CI, 0.98–1.43). Exposure to both crude oil and dispersant was positively associated with elevated risk for shortness of breath (HR = 2.24; 95%CI, 1.09–4.64). Conclusions: Among active duty Coast Guard personnel, oil spill clean-up exposures were associated with moderately increased risk for longer term respiratory conditions.

54 ENVIRONMENTAL SCIENCES↗

Identifying Disadvantaged Communities in the United States: An Energy-Oriented Mapping Tool that Aggregates Environmental and Socioeconomic Burdens

This paper defines a policy-relevant nationwide composite index to identify communities disproportionately impacted by environmental, energy, and climate injustices in the United States. We review existing vulnerability indicators and indices to assess the tradeoffs of different design parameters, including variable selection, geographic unit, dimensionality reduction, weighting, and aggregation methods. From this methodological review, we create the first nationwide, census tract-level index of cumulative burden that includes energy-relevant indicators alongside climate, social, environmental, and economic indicators, and is flexible to the inclusion of additional data sources. We provide a summary of the sources of inputs used to develop a definition for "disadvantaged communities" that can be used to prioritize energy investments. We discuss use-cases for this index including the implementation of the Justice40 Initiative, which calls for 40% of certain federal clean energy benefits to flow to disadvantaged communities in the United States. We use our results to examine historic allocations of federal energy investments and show that communities that we identify as disadvantaged received about 37% fewer funds per capita than non-disadvantaged communities.

cumulative burden↗

Opportunities and challenges in cathode development for non-lithium-ion batteries

Lithium (Li)-ion batteries have stimulated the societal transformation to clean energy systems. This carry-on electricity is revolutionizing how society communicates, functions, and evolves efficiently by enabling mobile electronics, zero-emission electric vehicles, and stationary energy storage. In preparation for the sustainable energy future, however, there are growing concerns about depleting critical elements used in the Li technology (e.g., lithium, cobalt, and nickel), especially for large-scale applications that will accelerate the rate of elemental consumption. Various non-Li-based rechargeable batteries composed of earth-abundant elements, such as sodium, potassium, magnesium, and calcium, have been proposed and explored as alternative systems to promote sustainable development of energy storage. In this perspective, we discuss challenges in Li-ion batteries in the sustainability aspect and provide our opinions on the potential applications of non-Li-based batteries. We also highlight the current status, important progress, and remaining challenges of the Li-alternative technologies.

25 ENERGY STORAGE↗

Tropical intertidal microbiome response to the 2024 Marine Honour oil spill

Marine fuel oil (MFO) spills in tropical coastal environments are under-characterized despite increasing risk from maritime activities. Microbial and geochemical responses to the June 2024 Marine Honour MFO spill on Singapore's intertidal sediments were analyzed in real time over 185 days. Using metagenomics and hydrocarbon profiling, microbial community shifts and hydrocarbon degradation were quantified across visibly oiled (high-impact) and clean (low-impact) sites. Microbiomes at all sites adapted rapidly to the spill through increased diversity and abundance of genes encoding alkane and aromatic compound degradation, detoxification, and biosurfactant production. The dominant hydrocarbon-degrading bacteria differed markedly from those reported in other crude oil spills and in regions with different climates. Oil deposition intensity strongly influenced microbial succession and hydrocarbon-degrading gene profiles, and this reflected early toxicity constraints in heavily oiled areas. The persistence of hydrocarbon degradation genes beyond hydrocarbon detection in sediments suggested long-term functional priming may occur. The study provides novel genome-resolved insight into the microbial response to MFO pollution, advances understanding of marine environmental biodegradation, and provides urgently needed baseline data for oil spill response strategies in Southeast Asia and beyond.

Coastal pollution↗

Multi-objective Decisions on Integrated Energy Systems Planning and Operation for Industrial Combined Heat and Power Supply

Unlike the power sector—which can transmit electricity over long distances via established grids—the industrial sector poses a unique challenge due to its geographically concentrated large-scale heat processes. Enhancing energy security in such industrial parks provides a dual benefit: reduced exposure to volatile fossil fuel prices and improved economic viability, largely driven by economies of scale in energy supply and distribution. This study presents a comprehensive technoeconomic analysis of a nuclear energy hub, employing a mechanism-focused approach to evaluate uncertainties in operational strategies and capacity optimization. Load profiles from three major energy intesive industries—chemical, refinery, and steelmaking—are examined, each presenting unique challenges and opportunities for nuclear energy integration. We adopt a multi-objective optimization framework, converting multiple objectives into a single objective function through the e-constraint method. The findings highlight clear trade-offs between system conditions and varying levels of energy independence. Overall, this analysis is granular enough to address industry-specific concerns yet sufficiently generalizable to provide actionable insights into the feasibility of nuclear-based clean heat solutions for the industrial sector.

25 - ENERGY STORAGE↗

Decontamination of urban surfaces contaminated with radioactive materials and consequent onsite recycling of the waste water

Enhancing rapid remediation strategies is paramount for recovery after a large-scale nuclear contamination event in an urban environment. Some current strategies recommend use of readily available equipment, materials, and facilities to expedite recovery. For example, applying pressurized water to contaminated surfaces may effectively remove radioactive contamination. In this study, a commercial power washer removes soluble forms of 152 Eu 3 + , 85 Sr 2 + , and 137 Cs + contamination from common porous building materials, and computer simulations characterize the recycling of the resultant contaminated wash water. Pressure washing the porous building materials under spray conditions typical with do-it-yourself units improved decontamination factors (DFs) for 152 Eu compared to low-pressure application of tap water (majority of two-tailed t-test p-values < 0.1), but pressure did not improve DFs for 137 Cs or 85 Sr. For both pressurized and low-pressure applications, adding potassium ions (K + ) to promote ion exchange reactions produced significantly higher DFs for tested radionuclides on asphalt, brick, and concrete. The resultant contaminated wash water can be processed through self-prepared chemical filtration beds of clay and sand. Modeled in a prior study, the beds yielded linear trends (R 2 > 0.98) in sensitivity analyses between most bed configuration variables and bed performance variables, permitting flexible ad-hoc bed design. The experimental and simulation results led to estimates of the remediation rate and waste generated after cleaning 250 m 2 of cesium-contaminated concrete from the combined deployment of a power washer and two different mobile treatment beds. Furthermore, the first treatment bed was designed to reduce treatment time and processed 1900 L of wash solution in 70 min using 880 kg of clay/sand infill material. Designed to reduce the solid waste generated, the second bed processed the same solution volume in 1040 min (17 h) using 170 kg of clay/sand infill material. The results of this analysis warrant further investigation of power washing with recycled salt solution as an effective rapid decontamination method with manageable waste.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Tailoring the rheological properties of high protein suspension by thermal-mechanical treatment

The viscoelasticity of concentrated protein suspensions associates closely with the mixing efficiency and cleaning frequency of facility during high-protein food development. This study investigated the effects of thermal-mechanical treatment on the viscoelasticity of milk protein isolate (MPI) suspensions and their underlying mechanisms to develop protein ingredient with low viscoelasticity. MPI suspensions (20%) were treated at 25, 50 and 85°C for 10-60 min under constant shear (100 s -1 ), followed by storage at 4°C. The viscosity (η) of MPI suspension treated at 50°C and 85°C was similar to 1-10% as those treated at 25 ° C. After four days of storage at 4°C, η showed the least value in 50°C-treated samples compared to those at 25 ° C and 85 ° C. The η and storage modulus (G') was decreased with prolonged treatment at 25 and 50°C, whereas opposite trend was found in 85°C treated samples. Differential scanning calorimetry found proteins in 50°C treated samples had smaller enthalpy than those in the control and 25°C treated samples. Protein surface hydrophobicity was increased slightly from 25°C to 50°C, but remarkably in 85°C treated samples. Ultra-small angle x-ray scattering showed the radius of gyration (R-g) of casein micelle was similar to 38 nm at 25°C and 50°C treated samples but increased to similar to 44 nm 85°C treated samples with reduced compactness. A new sphere-like structure with R-g of 18 nm was generated in 85°C treated samples. These findings suggested modulating temperature during thermal-mechanical treatment is essential to alter protein structures and morphology for desirable rheological properties.

59 BASIC BIOLOGICAL SCIENCES↗

Impacts of advanced diesel combustion operation and fuel formulation on soot nanostructure and reactivity

Advanced diesel combustion, accomplished via a single pulse fuel injection and high levels of exhaust gas recirculation (referred to as “PCCI”, partially-premixed charge compression ignition), is shown to be a path to reduce oxides of nitrogen and particulate matter simultaneously. This is well established in the literature. Less established is the extent to which such dilute combustion processes influence soot formation and affect soot that is emitted from diesel engines under such combustion modes. This work focuses on characterization of the nanostructure and oxidative reactivity of soot generated by a light-duty turbodiesel engine operating under a PCCI combustion mode, a dilute, low-temperature combustion process. Previous work on a type of PCCI combustion, referred to as high-efficiency clean combustion (HECC), showed soot samples having a fullerenic nanostructure, characterized by high levels of tortuosity of the fringe layers as seen in transmission electron micrograph images and as quantified using an image processing algorithm. Thermogravimetric analysis of the HECC mode soot samples showed that they displayed higher rates of oxidation than soot samples from a conventional diesel combustion mode. The present work returns to PCCI combustion, considering the timing of the main fuel injection, and the effects of operating on fuels rich in n-alkanes, particularly a fuel produced from a low temperature Fischer-Tropsch process (LTFT) and a renewable diesel fuel (RD) produced via hydrodeoxygenation of a plant oil. PCCI combustion conditions yield soot that shows higher reactivity compared to soot from the conventional combustion mode regardless of fuel type. LTFT and RD fuels produce soots with lower reactivity compared to ULSD. Soots produced from PCCI combustion have higher surface oxygen concentration and higher proportion of amorphous carbon. In addition, TEM images show that PCCI soots from all three fuels have smaller primary particle and particle aggregate sizes, and smaller graphene layers. These properties explain the higher reactivity of soot from PCCI combustion. The less reactive soots, which are produced from LTFT and RD fuel under conventional combustion, show internal burning during oxidation. However, soots with higher reactivity which are produced from late injection PCCI combustion and ULSD show shrinking core oxidation, most likely because of their overall amorphous structure.

42 ENGINEERING↗

Experimental and numerical investigation of proppant embedment and conductivity reduction within a fracture in the Caney Shale, Southern Oklahoma, USA

The current worldwide energy supply is insufficient to meet the rising demand. As a result, the energy prices are expected to keep soaring despite the recent increases in a variety of renewable energy resources. Although not renewable, shale oil and gas — “unconventional” hydrocarbon resources are relatively clean forms of energy resources, which still hold a vast share of the energy market. For many oil and gas companies, meeting profitable production goals from shale reservoirs is sometimes challenging, due to the loss of fracture conductivity and premature declines in the production. In this paper we investigate the stress-dependent changes in the hydraulic conductivity of proppant-filled fractures and mechanical fracture–proppant interactions in Caney Shale, a calcareous, organic-rich mudrock, through laboratory experiments and numerical modeling. American Petroleum Institute (API) fracture conductivity tests were conducted using 2% KCl on five locations within the Caney Shale that consisted of selecting three brittle (reservoir) zones and two ductile zones. Confining pressures ranged from 1,000 psi to 12,000 psi at 210 °F. Conductivity, permeability as well as embedment were measured during the test. Also, an additional, laboratory in-situ visualization test was conducted to examine the detailed proppant-shale matrix interaction under elevated stress (3,920 psi effective stress) and temperature (252 °F), with a synthetic reservoir fluid. Our experimental results have confirmed that improved fracture conductivity is attributed to proppant size, and that the increase in porosity of the proppant pack, closure pressure changes and the reduction in fracture conductivity are a function of many factors such as fracture closure stress.

04 OIL SHALES AND TAR SANDS↗

Boosting the performances of protonic solid oxide fuel cells for co-production of propylene and electricity from propane by integrating thermo- and electro- catalysis

Protonic solid oxide fuel cells (p-SOFC) integrated with clean thermal energy sources are promising platforms for decarbonized chemical production in addition to power generation, such as on-purpose propylene production from propane dehydrogenation (PDH). The catalytic performance of the conventional nickel-cermet-based anode materials in p-SOFC for propane conversion is restrained by their low active surface area and proneness to coking. In this work, by integration of a highly efficient industry-relevant thermal catalyst PtGa/ZSM-5 for PDH reaction, we demonstrate that both the electrochemical and catalytic performance of the propane-fueled p-SOFC can be effectively enhanced. The PtGa catalyst integrated p-SOFC exhibits a peak power density of 93 mW cm -2 at 600°C, which is greater by about 100% and 50% than that without catalyst or with a perovskite-based (Pr 0.3 Sr 0.7 ) 0.9 Ni 0.1 Ti 0.9 O 3 (PSNT) catalyst layer, respectively. The PDH activity and olefin selectivity of the PtGa catalyst is also significantly higher than that of the PSNT catalyst. In addition, much improved coke tolerance and propylene selectivity (over 90%) compared to the catalyst-free Ni-cermet anode materials were achieved by integrating the industrial catalyst layer. The propane conversion can be further improved by an applied current density, whereas the olefin selectivity is almost unaltered. The excellent performance of the PtGa catalyst integrated p-SOFC is attributed to the high surface area, intrinsically high catalytic activity, selectivity, and anti-coking properties of the catalytic layer for propane conversion. In conclusion, this work provides a general approach and a case study for boosting the performances of p-SOFCs in chemical production by integrating thermo- and electro- catalysis.

30 DIRECT ENERGY CONVERSION↗

Atomic and ionic hydrogen flux probe for quantitative in-situ monitoring of hydrogen recycling

A new combination diagnostic as a hydrogen recycling monitor in harsh conditions is proposed. Combining permeation membrane probe with a Langmuir probe provides a possibility to measure both atomic and ionic hydrogen fluxes to plasma facing components. A brief overview of permeation probes is given. The range of measurable H fluxes is from 10 16 to more than 10 20 H m –2 s –1 . Time response of the permeation probe is ~ 0.1–0.5 s. A method to address disadvantages of permeation probes is proposed. This includes an introduction of a preparation chamber for Ar-plasma cleaning of the membrane and absolute calibration with a visible spectroscopy. The hydrogen recombination coefficient, evaluated in such calibration, is k u = 5.9 × 10 –30 m 4 s –1 , which agrees well with previous research.