Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Capacity Building”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Experimental Studies of NaK in a Simulated Space Environment

Space fission power systems are being developed at the National Aeronautics and Space Administration (NASA) and Department of Energy (DOE) with a short term goal of building a full scale, non-nuclear, Technology Demonstration Unit (TDU) test at NASA's Glenn Research Center. Due to the geometric constraints, mass restrictions, and fairly high temperatures associated with space reactors, liquid metals are typically used as the primary coolant. A eutectic mixture of sodium (22 percent) and potassium (78 percent), or NaK, has been chosen as the coolant for the TDU with a total system capacity of approximately 55 L. NaK, like all alkali metals, is very reactive, and warrants certain safety considerations. To adequately examine the risk associated with the personnel, facility, and test hardware during a potential NaK leak in the large scale TDU test, a small scale experiment was performed in which NaK was released in a thermal vacuum chamber under controlled conditions. The study focused on detecting NaK leaks in the vacuum environment as well as the molecular flow of the NaK vapor. This paper reflects the work completed during the NaK experiment and provides results and discussion relative to the findings.

Gibons, Marc↗

Design and Performance of Solar Decathlon 2011 High-Penetration Microgrid: Preprint

The U.S. Department of Energy Solar Decathlon challenges collegiate teams to design, build, and operate solar-powered houses that are cost-effective, energy-efficient, and attractive. The Solar Decathlon 2011 was held in Washington, D.C., from September 23 to October 2, 2011 . A high-penetration microgrid was designed, installed, and operated for the Solar Decathlon 2011 to grid-connect 19 highlyenergy-efficient, solar-powered competition houses to a single utility connection point. The capacity penetration of this microgrid (defined as maximum PV generation divided by maximum system load over a two-week period) was 74% based on 1-minute averaged data. Temporary, ground-laid conductors and electrical distribution equipment were installed to grid-connect the Solar Decathlon village,which included the houses as well as other electrical loads used by the event organizers. While 16 of the houses were connected to the 60 Hz microgrid, three houses from Belgium, China, and New Zealand were supplied with 50 Hz power. The design of the microgrid, including the connection of the houses powered by 50 Hz and a standby diesel generator, is discussed in this paper. In addition to theutility-supplied net energy meters at each house, a microgrid monitoring system was installed to measure and record energy consumption and PV energy production at 1-second intervals at each house. Bidirectional electronic voltage regulators were installed for groups of competition houses, which held the service voltage at each house to acceptable levels. The design and successful performance ofthis high-penetration microgrid is presented from the house, microgrid operator, and utility perspectives.

14 SOLAR ENERGY↗

A Low Carbon Development Guide for Local Government Actions in China

Local level actions are crucial for achieving energy-saving and greenhouse gas emission reduction targets. Yet it is challenging to implement new policies and actions due to a lack of information, funding, and capacity. This is particularly the case in developing countries such as China. Even though national energy intensity and carbon intensity targets have been set, most local governments do not have the knowledge regarding actions to achieve the targets, the cost-effectiveness of policies, the possible impact of policies, or how to design and implement a climate action plan. This paper describes a guidebook that was developed to motivate and provide local governments in China with information to create an action plan to tackle climate change and increase energy efficiency. It provides a simple step-by-step description of how action plans can be established and essential elements to be included - from preparing a GHG emission inventory to implementation of the plan. The guidebook also provides a comprehensive list of successful policies and best practices found internationally and in China to encourage low carbon development in industry, buildings, transportation, electric power generation, agriculture and forestry. This paper also presents indicators that can be used to define low-carbon development, as well as to evaluate the effectiveness of actions taken at an aggregated (city) level, and at a sectoral or end use level. The guidebook can also be used for low carbon development by local governments in other developing countries.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Building America Case Study: Simple Retrofit High-Efficiency Natural Gas Water Heater Field Test, Minneapolis, Minnesota

High performance water heaters are typically more time consuming and costly to install in retrofit applications, making high performance water heaters difficult to justify economically. However, recent advancements in high performance water heaters have targeted the retrofit market, simplifying installations and reducing costs. Four high efficiency natural gas water heaters designed specifically for retrofit applications were installed in single-family homes along with detailed monitoring systems to characterize their savings potential, their installed efficiencies, and their ability to meet household demands. The water heaters tested for this project were designed to improve the cost-effectiveness and increase market penetration of high efficiency water heaters in the residential retrofit market. The retrofit high efficiency water heaters achieved their goal of reducing costs, maintaining savings potential and installed efficiency of other high efficiency water heaters, and meeting the necessary capacity in order to improve cost-effectiveness. However, the improvements were not sufficient to achieve simple paybacks of less than ten years for the incremental cost compared to a minimum efficiency heater. Significant changes would be necessary to reduce the simple payback to six years or less. Annual energy savings in the range of $200 would also reduce paybacks to less than six years. These energy savings would require either significantly higher fuel costs (greater than $1.50 per therm) or very high usage (around 120 gallons per day). For current incremental costs, the water heater efficiency would need to be similar to that of a heat pump water heater to deliver a six year payback.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A heuristic tool to assess regional impacts of renewable energy infrastructure on conservation areas

Wind and hydropower are important renewable components of national energy portfolios, but their infrastructure negatively affects biodiversity. Regional development requires identification of scenarios that minimize the cumulative impacts of multiple facilities. We introduce the cumulative impact plot (CIP) to quantify cumulative impacts of renewable energy development within a region. Summed impacts of facilities are plotted as a function of the number of facilities, with facilities ranked by increasing (the best-case scenario) or decreasing (worst-case scenario) individual impact. These curves represent lower and upper bounds to which alternative development scenarios (e.g., facilities ranked by generating capacity) can be compared. We used CIPs to assess overlap of potential wind and hydropower facilities with two types of conservation area in the United States: (1) federally protected lands and (2) critical habitats of federally threatened and endangered species. Here, we evaluated two alternative scenarios: facilities ranked by (A) decreasing generating capacity and (B) increasing distance from urban centers. Differences between the best-case and worst-case scenarios were large, thus revealing opportunities to develop facilities with limited impact on conservation areas. Alternative scenarios maximizing energy density generally resulted in conservation area overlap intermediate to best-case and worst-case scenarios. CIPs can also identify the proportion of wind versus hydropower favored under alternative scenarios. Build-out scenarios aimed at minimizing conservation area overlap favor hydropower, whereas alternative scenarios favor wind power. We conclude that CIPs can (1) complement—but should not replace—project-level environmental impact assessment, (2) integrate strategic, cumulative, and scenario-based assessments, and (3) harness rapidly growing geospatial data.

54 ENVIRONMENTAL SCIENCES↗

Deconvoluting the benefits of porosity distribution in layered electrodes on the electrochemical performance of Li-ion batteries

Thick Lithium Ion Battery (LIB) electrodes suffer from poor rate capability and high ionic impedance due to their thickness and mesostructure. Therefore, optimizing thick electrode architectures becomes crucial. In this work, we report a systematic assessment of the ionic resistance in heterogeneous porous electrodes through the combination of computational simulations using a 4D-resolved model and experimental measurements. The first part of the study is devoted to a general assessment of Electrochemical Impedance Spectroscopy (EIS) spectra, mapping the impact of ionic and electronic resistances on the overall impedances of uncalendered and calendered LiNi 1/3 Mn 1/3 Co 1/3 O 2 , LiFePO 4 and graphite electrodes. In the second part, in silico-generated electrodes with different porosities are used in computational EIS simulations to analyze the impact of the electrode porosity on the ionic impedance. As expected, the results show that a lower porosity leads to a higher ionic impedance because of a higher electrode tortuosity factor. Furthermore, in silico-generated electrodes with different porosities were stacked and assembled to create heterogeneities of porosity along the thickness, and used in computational EIS and galvanostatic discharge simulations. The computational results show that the porosity heterogeneity along the electrode thickness has a significant effect on the ionic impedance and capacity of the electrode. The electrode architecture with progressively decreasing porosity from separator to current collector shows the highest performance, a trend validated by our in house experimental EIS and galvanostatic discharge also reported in this manuscript. Overall, we conclude that the ionic resistance in a thick electrode can be effectively reduced through proper tuning of the porosity heterogeneity. The proposed heterogeneous electrode architectures presented here could enormously help building efficient thick electrodes for LIBs.

25 ENERGY STORAGE↗

Cathode porosity is a missing key parameter to optimize lithium-sulfur battery energy density

While high sulfur loading has been pursued as a key parameter to build realistic high-energy lithium-sulfur batteries, less attention has been paid to the cathode porosity, which is much higher in sulfur/carbon composite cathodes than in traditional lithium-ion battery electrodes. For high-energy lithium-sulfur batteries, a dense electrode with low porosity is desired to minimize electrolyte intake, parasitic weight, and cost. Here we report the profound impact on the discharge polarization, reversible capacity, and cell cycling life of lithium-sulfur batteries by decreasing cathode porosities from 70 to 40%. According to the developed mechanism-based analytical model, we demonstrate that sulfur utilization is limited by the solubility of lithium-polysulfides and further conversion from lithium-polysulfides to Li2S is limited by the electronically accessible surface area of the carbon matrix. Finally, we predict an optimized cathode porosity to maximize the cell level volumetric energy density without sacrificing the sulfur utilization.

25 ENERGY STORAGE↗

The ECP SICM project: Managing complex memory hierarchies for exascale applications

The Exascale Computing Project (ECP)’s Simplified Interface to Complex Memories (SICM) effort focuses on developing universal interfaces for discovering, managing, and sharing data across complex memory hierarchies. These facilitate the exploitation of emerging memory technologies and support precise control over their various trade-offs such as high-bandwidth versus low-latency, persistent versus ephemeral, high-capacity versus low-capacity, and near-CPU versus near-GPU. SICM comprises three interrelated components: a low-level interface, a high-level interface, and a persistent-heap interface. The low-level SICM interface is intended for system and run-time developers as well as expert application developers who prefer full control of the memory objects used within their application. The high-level SICM interface builds upon the low-level interface, employing application-level profiling and analysis to optimize data management for complex memory hierarchies. The persistent-heap interface provides applications with a persistent memory allocator that can allocate custom C++ data structures in both block-storage and byte-addressable persistent memories.

97 MATHEMATICS AND COMPUTING↗

Initial and Long-Term Movement of Cladding Installed Over Exterior Rigid Insulation

Changes in the International Energy Conservation Code (IECC) from 2009 to 2012 have resulted in the use of exterior rigid insulation becoming part of the prescriptive code requirements. With more jurisdictions adopting the 2012 IECC builders are going to finding themselves required to incorporate exterior insulation in the construction of their exterior wall assemblies. For thick layers of exterior insulation (levels greater than 1.5 inches), the use wood furring strips attached through the insulation back to the structure has been used by many contractors and designers as a means to provide a convenient cladding attachment location. However, there has been a significant resistance to its widespread implementation due to a lack of research and understanding of the mechanisms involved and potential creep effects of the assembly under the sustained dead load of a cladding. This research was an extension on previous research conducted by BSC in 2011, and 2012. Each year the understanding of the system discrete load component interactions, as well as impacts of environmental loading has increased. The focus of the research was to examine more closely the impacts of screw fastener bending on the total system capacity, effects of thermal expansion and contraction of materials on the compressive forces in the assembly, as well as to analyze a full years worth of cladding movement data from assemblies constructed in an exposed outdoor environment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field Performance of Inverter-Driven Heat Pumps in Cold Climates

Traditionally, air-source heat pumps (ASHPs) have been used more often in warmer climates; however, some new ASHPs are gaining ground in colder areas. These systems operate at subzero (Fahrenheit) temperatures and many do not include backup electric resistance elements. There are still uncertainties, however, about capacity and efficiency in cold weather. Also, questions such as “how cold is too cold?” do not have clear answers. These uncertainties could lead to skepticism among homeowners; poor energy savings estimates; suboptimal system selection by heating, ventilating, and air-conditioning contractors; and inconsistent energy modeling. In an effort to better understand and characterize the heating performance of these units in cold climates, the U.S. Department of Energy Building America team, Consortium for Advanced Residential Buildings (CARB), monitored seven inverter-driven, ductless ASHPs across the Northeast. Operating data were collected for three Mitsubishi FE18 units, three Mitsubishi FE12 units, and one Fujitsu 15RLS2 unit. The intent of this research was to assess heat output, electricity consumption, and coefficients of performance (COPs) at various temperatures and load conditions. This assessment was accomplished with long- and short-term tests that measured power consumption; supply, return, and outdoor air temperatures; and airflow through the indoor fan coil.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Removable, Sequestration Coatings for Mitigating Hazardous Contaminants Related to Deactivation and Decommissioning Activities

This project is a collaborative effort between InnoSense LLC (ISL) and Oak Ridge National Laboratory (ORNL) aimed at mitigating the mercury (Hg) contamination problem at the Y-12 National Security Complex (NSC). The report summarizes the research and technology development work of the Phase IIB Project, led by Dr. Uma Sampathkumaran at ISL for the period of July 31, 2017–October 31, 2021. The Y-12 site cleanup includes technologies for safe and cost-effective facility demolition, soil remediation, and on-site treatment and disposal of mercury bearing wastes. One of the technology demonstration goals was a reactive strippable coating for targeted pre-demolition and de-contamination to limit Hg mobilization and the volume of debris requiring treatment for disposal. Toward this, ISL has developed a water-based reactive strippable coating (Trap & See-Hg™) to sequester elemental Hg(0) and mercuric Hg(II) species in the coating. The coating provides multiple benefits including (1) Hg vapor suppression, (2) sealing in the hazardous contaminants, (3) visually locating the contaminant through color changes, and (4) remediating the contaminated surfaces upon coating removal. Through collaboration between ORNL and ISL in Phase II work, the team successfully demonstrated the Trap & See-Hg technology to (1) visually locate the presence of Hg on concrete, soil and drywall surfaces, (2) effectively sequester all mercury species (elemental, soluble and insoluble Hg) from lab-generated and ex-situ soil and brick/rubble samples collected from the Y 12 site with 80 to 95% efficiency to capture/reduce Hg vapor concentration, (3) be applied by manual and robotic spray applicators and cure at room ambient, (4) remain a cohesive and peelable coating upon drying, and (5) sequester Hg0 from walls in the alpha-2 building basement at Y-12 during a small scale in-situ field trial. In Phase IIB, ISL’s effort was focused on refining the coating formulations with additives containing passive and reactive sorbents, colorimetric indicator, and thixotropic agents to achieve the desired performance. The paints were then evaluated at ORNL for applicability to metal and concrete surfaces of different sizes and shapes, and soil rubble, Hg-sorption capacity and achieving sag-free coating on surfaces when applied by a manual spray applicator. Ambient cure of the coating resulted in a dry thickness of 16–20 mil. The coatings were removed from smooth or rough surfaces with low to moderate force. Both lab-generated Hg-contaminated samples and soil and brick/rubble samples containing a range of Hg concentrations (collected from the Y-12 site by UCOR) were used in this project. Optimized formulations were applied to these samples and evaluated for ability to suppress Hg vapors, sequester Hg 0 and Hg(II) species and color mapping of mercury species on the test surface. The ORNL team initially identified three to four potential sites at Y-12 and ORNL for potential demonstration. However, the pandemic closed any possible avenues for on-site demonstration of the robotic spray applicator. The metal and concrete samples with low to high Hg content provided by UCOR from an ongoing demolition were subsequently used for ex-situ sample characterization and analysis at ORNL over a period of 25 days. The coatings suppressed Hg vapors with an efficiency of 95–99% from heavily contaminated metal and 60% from concrete substrate. Analysis of total Hg in the peeled paints indicates sorption capacities ranging from 12 µg Hg/g of paint from concrete to 1.2 mg Hg/g of paint from the metal substrates while peeled paints from soil samples could capture a total Hg from 2.3 mg Hg/g to 66 mg/g paint. Toxicity characteristic leaching procedure (TCLP) tests recovered total mercury leached at 0.15±0.0008 µg/L for concrete to 126.81±0.67 µg/L and 377.25±5.67 µg/L for the two metal substrates, to allow for informed decisions on downstream disposal considerations. Together, this Phase IIB demonstrated the potential value of the Trap & See-Hg for Hg uptake, vapor suppression, and color mapping, and may thus be used to enhance worker safety during site cleanup, facility demolition, and downstream waste disposal at Y-12 NSC.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hydrogel-Salt Hydrate Composite for Highly Stable Heat Energy Storage with Reduced Supercooling

Phase change materials (PCM) have potential for use in thermal energy storage in buildings, medical devices, and water heat pumps. Sodium sulfate hydrate (SSD) is appealing due to its high energy storage capability and affordability. However, SSD has issues including high supercooling (> 15°C) and low thermal cyclic stability. In this study, we introduced an ionic molecular nucleating agent that decreases the supercooling temperature to under 2°C. When this SSD was combined with a hydrogel, it maintained its thermal energy storage capacity for over 100 cycles without any decline. The success is attributed to the polymer confining the SSD crystals, preventing large-scale phase separation and the nucleating agent which resulted in nucleation of many small SSD crystals at small undercoolings rather than a small number of larger crystals. As a proof-of-application, we synthesized this composite at a kg scale and demonstrated its properties in a close to real-world demonstration.

chemical composition, thermodynamics↗

Providing Global Change Information for Decision-Making: Capturing and Presenting Provenance

Global change information demands access to data sources and well-documented provenance to provide evidence needed to build confidence in scientific conclusions and, in specific applications, to ensure the information's suitability for use in decision-making. A new generation of Web technology, the Semantic Web, provides tools for that purpose. The topic of global change covers changes in the global environment (including alterations in climate, land productivity, oceans or other water resources, atmospheric composition and or chemistry, and ecological systems) that may alter the capacity of the Earth to sustain life and support human systems. Data and findings associated with global change research are of great public, government, and academic concern and are used in policy and decision-making, which makes the provenance of global change information especially important. In addition, since different types of decisions benefit from different types of information, understanding how to capture and present the provenance of global change information is becoming more of an imperative in adaptive planning.

provenance tracking↗

Definition of Capabilities Needed for a Single Event Effects Test Facility

The Federal Aviation Administration (FAA) is contemplating new regulations mandating testing of the vulnerability of flight-critical avionics to single event effects (SEE). A limited number of high-energy neutron test facilities currently serve the SEE industrial and institutional research community. The FAA recognizes that existing facilities have insufficient test capacity to meet new demand from such mandates; it desires more flexible irradiation capabilities to test complete, large systems and would like capabilities to address greater concerns for thermal neutrons. For this reason, the FAA funded this study by Spallation Neutron Source (SNS) staff with the ultimate aim of developing options for SEE test facilities using high-energy neutrons at the SNS complex. After an investigation of current SEE test practices and assessment of future testing requirements, three concepts were identified covering a range of test functionality, neutron flux levels, and fidelity to the atmospheric neutron spectrum. The costs and times required to complete each facility were also estimated. SEE testing is generally performed by accelerating the event rate to a point where the effects are still dominated by single events and double event causes of failures are negligible. In practice, acceleration factors of as high as 10 6 are applicable for component testing, whereas for systems testing acceleration factors of 10 4 seem to be the upper limit. It is strongly desirable that the irradiation facility be tunable over a large range of high-energy neutron fluxes of 10 2 - 10 4 n/cm²/s for systems testing and from 10 4 - 10 7 n/cm²/s for components testing. The most capable, most flexible, and highest-test-capacity option is a new stand-alone target station named the High-Energy neutron Test Station (HETS). It is also the most expensive option, with a cost to complete of approximately $100 million. Dual test enclosures would allow for simultaneous testing activity effectively doubling overall test capacity per HETS operating hour. Using about 1 kilowatt (kW) of proton power extracted from the accelerator before injection in the accumulator ring, its operation would be unnoticeable by neutron scattering users at the SNS target station. The H beam laser stripping technique would allow for control of beam power on the HETS target independent from power delivered to the SNS. Large systems with frontal areas of up to 1 x 2 m² could be accommodated with integral high-energy flux values (above 10 megaelectron-volt, or MeV) to at most 10 4 n/cm²/s; components could also be tested with flux levels to at most 10 7 n/cm²/s on beam sizes of up to 0.2 x 0.2 m². Selectable moderating material and neutron filters would allow tailoring of the neutron spectrum to user demands; charged particle deflectors could be switched to allow or deflect protons, pions, and muons. It is estimated that HETS would take 5 years to complete after award of contract, including engineering design and construction. Commissioning would take at least another 6 months. Interference with SNS principal operations was not considered in the construction time estimate; connection of the proton transport line and tunnel from the accelerator high energy beam transport (HEBT) and construction around existing site utilities would require careful planning and coordination with beam operations at the SNS. A high-energy (HE) neutron test facility using an available beam line on the SNS target station is a technically and financially attractive option. Inspired by the new ChipIR instrument on the ISIS TS 2 spallation source in the UK, a similar facility could be placed on an unused beam line in the SNS instrument hall [e.g., on beam line 8 (both A and B channels would be needed) or on beam line 10]. The performance would approach that of an HETS (~80%), but it would be operationally more limited, with only a single user at a time. Space is more limited, so the maximum system size would be about half of that in an HETS. Flexibility to tailor the spectrum would be somewhat more limited. While this concept was not as fully developed and characterized, preliminary work indicates very high HE flux levels should be possible, with ample thermal neutrons as well. Flux control would be more difficult than at HETS because proton power on target be whatever the SNS was operating at for neutron scattering. Neutron attenuation devices would have to be employed with as-yet undetermined control resolution. However, no new buildings would be needed, and the necessary utilities are already present in the SNS Experiment Hall. The estimated cost for a beam line option is around $15 million; the time to complete would be 3 years after award of contract, plus at least 6 months for commissioning. Interference of construction activities with SNS operations should be negligible. This option would require negotiation with the Department of Energy Basic Energy Sciences (BES) office -- the primary stakeholder of SNS -- for an application outside the usual scope of neutron scattering sciences. Furthermore, these presently open beam lines are highly desirable locations for proposed neutron scattering instruments and obtaining one of them for an SEE test facility will come only with persuasive and timely arguments to SNS leadership and the DOE BES. The third option is a tunnel extension/target cave facility providing the most basic system-level irradiation capability with minimal flexibility. Again not as well developed a concept as HETS, it would use a laser-stripping technique like an HETS, redirecting protons to a tunnel similar to the initial HETS proton transport tunnel. Indeed, this concept is intended to be upgradable to a full HETS facility. Only a small fraction of a watt of proton power would be used in this basic configuration, though. An uncooled target and primitive shielding arrangement would provide beam on modestly sized systems that must be placed in close proximity to the target. The neutron fluence would be less uniform over the system than with the HETS or the beam line option. A data acquisition room and support area would be located on the ground level; access to the target cave would be via elevator and/or stairway. As a result of the required excavation, new tunnel construction, shielding, data acquisition building, utilities, and other items, the estimated cost is $30 million. The time to complete is expected be more than 3 years; here again construction interference with SNS operations has not been accounted for, but it could have a significant impact.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fiscal Year 2015 Site Sustainability Plan

Los Alamos National Laboratory is taking action to operate as a living laboratory for sustainable solutions in buildings, climate, energy, purchasing, transportation, waste, and water. LANL prepared the fiscal year (FY) 2015 Site Sustainability Plan (SSP) to describe progress towards the goals established in the SSPP. In addition, per the requirements of DOE Order 436.1, Departmental Sustainability, Los Alamos National Laboratory (LANL) uses its International Organization for Standardization (ISO) 14001:2004 certified Environmental Management System (EMS) to establish objectives to improve compliance, reduce environmental impacts, increase operational capacity, and meet long-term sustainability goals. The goals of the 2015 SSP are fully integrated into LANL’s institutional environmental objectives under the EMS and its Long-Term Strategy for Environmental Stewardship & Sustainability (LTSESS).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

US Hybrid Northeast Demonstration and Deployment of FCRxNV200 (DE-EE0007276 Final Report)

In this project, US Hybrid and other strategic project partners, collaborated to build a fuel cell range extended plug-in hybrid utility vehicle and demonstrate it in real-world operation. The base vehicle platform to be modified to the hybrid platform was the Nissan e-NV200, which is an all-electric version of the NV200 commercial cargo van. This is a Class 1 vehicle with a GVWR of approx. 4,900 lbs., wheelbase of 115 inches, and cargo capacity of approx. 122ft. The 80kW/254N-m electric powertrain is the same as Nissan’s LEAF, but with a revised final drive ratio (9.301 vs. 8.194) to accommodate higher payloads with lower top speed. US Hybrid utilized a purpose built, freeze capable, integrated fuel cell engine FCe™10 to hybridize and range-extend the existing e-NV200 vehicle with OEM drivetrain. The eNV200 has the same size battery as the LEAF with a different rear axle ratio. Fuel cell stack size and balance of plant (BOP) configuration were designed for compact under the hood vehicle packaging. Engine design took into consideration the need for high efficiency (>50% at all loads & up to 62% at partial power), optimal heat recovery for cabin heating, and low maintenance. The technology of the isolated DC-DC converter operating at >100kHz enables extremely high efficiency (ZVS and SIC power devices) and robust performance while reducing system complexity, weight, and volume. This enables an extended vehicle range of up to 250 miles and an operational life that should provide lower total cost of ownership (TCO) to the end user.

33 ADVANCED PROPULSION SYSTEMS↗

Fabrication of Biofunctionalized PVA/PEI Nanofibers for Rare Earth Element Extraction from Coal Mine Tailings

The need for rare earth elements (REEs) for new technology is becoming increasingly stiff with demand at a record high. Biological ligands like lanmodulin and lanthanide binding tags (LBT) have gained noticeable attention for their selective extraction of valuable lanthanide metals in aqueous solution. Building on previous work using microbeads as the extraction media, we propose that nanofibers can improve extraction capabilities. Nanofibers could provide more efficient flow and higher extraction yields due to their high surface area to volume ratio. Relying on thiolmaleimide click chemistry as the biological ligand immobilization route, electrospinning as the nanofiber manufacturing method, and numerous characterization techniques, we produced electrospinning polymer solutions and nanofibers with a maximum neodymium adsorbent capacity of 12.1 μmol/g of extraction media immobilized with LBT. Although the prior work produced an extraction media with an equivalent capacity of ~40 μmol/g, the electrospinning process is much more economical and scalable. This work paves the way for an industrially relevant, environmentally-friendly REE extraction material. Further work is required to produce higher quality nanofibers, to investigate common ion interference with REE adsorbance, and to scale production up to a relevant scale.

01 COAL, LIGNITE, AND PEAT↗

Environmental Management Waste Management Facility Operations Team Commitment to Safety - 18546

The Environmental Management Waste Management Facility (EMWMF) is an above-grade waste disposal facility that is owned by DOE and operated by URS | CH2M Oak Ridge LLC (UCOR), a contractor to DOE's Oak Ridge Office of Environmental Management. The EMWMF landfill is located on the Oak Ridge Reservation (ORR) and has a 2.18 M cubic yard capacity. EMWMF is a key component of the cost-effective ORR cleanup program and accepts remediation waste from across the ORR. Multiple low-level and low-level mixed CERCLA waste streams are disposed at EMWMF, mostly as direct-dumped demolition and remediation debris. EMWMF receives and disposes of a myriad of contaminated waste streams and waste types, including massive structural steel from some of the largest buildings ever constructed, contaminated soils from legacy disposal areas, containers that must be grouted under negative pressure, and special waste that must be tightly controlled. Support activities include managing several million gallons of landfill wastewater per year and driving around 20,000 miles per year to transport leachate to a treatment facility. Even with the wide range of waste accepted and the diversity of support activities, EMWMF Operations has maintained an impressive safety record of no lost workday cases in nearly 16 years of continuous operation and was recently awarded the National Safety Council's Superior Safety Performance Award. This safety record is a testament to the commitment to safety by both workers and management. Several factors are key to the EMWMF Operations safety record. UCOR senior management established safety as a priority and allocates proper funding and resources. EMWMF Operations management embraces safety as an integral part of the work and also 'walks the talk'-emphasizing safety over productivity and showing personal commitment to safety. A stable workforce promotes a culture where safety is valued and helps train new personnel in this culture. The UCOR integrated safety management approach to work control is fully embraced, where worker feedback is highly valued and used to better identify and control job hazards. Finally, job supervisors actively encourage input. Worker concerns, suggestions, and observations are encouraged and positively addressed. As a result, the entire Operations Team is committed to identifying and mitigating hazards. This team commitment to safety results in a culture where safety is not only valued, but is expected. Safety concerns are identified and addressed proactively, and communication is encouraged. This strong safety culture and outstanding safety record have also proven to be good business, with the facility available to receive waste 99.6% of available work hours and outstanding turnaround times on waste shipments. The EMWMF Operations team commitment to safety can be used in other environments to develop an engaged, safety-conscious workforce. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗