Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CERTIFICATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Modeling spatial effects of PM{sub 2.5} on term low birth weight in Los Angeles County

Air pollution epidemiological studies suggest that elevated exposure to fine particulate matter (PM{sub 2.5}) is associated with higher prevalence of term low birth weight (TLBW). Previous studies have generally assumed the exposure–response of PM{sub 2.5} on TLBW to be the same throughout a large geographical area. Health effects related to PM{sub 2.5} exposures, however, may not be uniformly distributed spatially, creating a need for studies that explicitly investigate the spatial distribution of the exposure–response relationship between individual-level exposure to PM{sub 2.5} and TLBW. Here, we examine the overall and spatially varying exposure–response relationship between PM{sub 2.5} and TLBW throughout urban Los Angeles (LA) County, California. We estimated PM{sub 2.5} from a combination of land use regression (LUR), aerosol optical depth from remote sensing, and atmospheric modeling techniques. Exposures were assigned to LA County individual pregnancies identified from electronic birth certificates between the years 1995-2006 (N=1,359,284) provided by the California Department of Public Health. We used a single pollutant multivariate logistic regression model, with multilevel spatially structured and unstructured random effects set in a Bayesian framework to estimate global and spatially varying pollutant effects on TLBW at the census tract level. Overall, increased PM{sub 2.5} level was associated with higher prevalence of TLBW county-wide. The spatial random effects model, however, demonstrated that the exposure–response for PM{sub 2.5} and TLBW was not uniform across urban LA County. Rather, the magnitude and certainty of the exposure–response estimates for PM{sub 2.5} on log odds of TLBW were greatest in the urban core of Central and Southern LA County census tracts. These results suggest that the effects may be spatially patterned, and that simply estimating global pollutant effects obscures disparities suggested by spatial patterns of effects. Studies that incorporate spatial multilevel modeling with random coefficients allow us to identify areas where air pollutant effects on adverse birth outcomes may be most severe and policies to further reduce air pollution might be most effective. - Highlights: • We model the spatial dependency of PM{sub 2.5} effects on term low birth weight (TLBW). • PM{sub 2.5} effects on TLBW are shown to vary spatially across urban LA County. • Modeling spatial dependency of PM{sub 2.5} health effects may identify effect 'hotspots'. • Birth outcomes studies should consider the spatial dependency of PM{sub 2.5} effects.

54 ENVIRONMENTAL SCIENCES↗

Residential agricultural pesticide exposures and risks of preeclampsia

Highlights: • Pesticides and preeclampsia have been rarely investigated. • Studied were >200,000 births and exposures to >500 pesticides. • There was a general lack of association between pesticide exposures and preeclampsia. • It is possible that unobserved early fetal loss may have biased risk estimates. We investigated risks of preeclampsia phenotypes from potential residential pesticide exposures, including 543 individual chemicals and 69 physicochemical groupings that were applied in the San Joaquin Valley of California during the study period, 1998–2011. The study population was derived from birth certificate data linked with Office of Statewide Health Planning and Development maternal and infant hospital discharge data. The following numbers of women with preeclampsia phenotypes were identified: 1045 with superimposed (pre-existing hypertension with preeclampsia) preeclampsia (265 with gestational weeks 20–31 and 780 with gestational weeks 32–36); 3471 with severe preeclampsia (824 with gestational weeks 20–31 and 2647 with gestational weeks 32–36); and 2780 with mild preeclampsia (207 with gestational weeks 20–31 and 2573 with gestational weeks 32–36). The reference population for these groups was 197,461 women who did not have diabetes (gestational or pre-existing), did not have any hypertensive disorder, and who delivered at 37 weeks or later. The frequency of any exposure was lower or about the same in each preeclampsia case group (further delineated by gestational age), and month time period, relative to the frequency in reference population controls. Nearly all odds ratios were below 1.0 for these any vs no exposure comparisons. This study showed a general lack of increased risks between a range of agriculture pesticide exposures near women's residences and various preeclampsia phenotypes.

60 APPLIED LIFE SCIENCES↗

Assessment of human nuclear and mitochondrial DNA qPCR assays for quantification accuracy utilizing NIST SRM 2372a

In forensic DNA casework, a highly accurate real-time quantitative polymerase chain reaction (qPCR) assay is recommended per the Scientific Working Group on DNA Analysis Methods (SWGDAM) (SWGDAM Validation Guidelines for DNA Analysis Methods [1]) to determine whether a DNA sample is of sufficient quantity and robust quality to move forward with downstream short tandem repeats (STR) or sequencing analyses. Most of these assays rely on a standard curve, referred to herein and traditionally as absolute qPCR, in which an unknown is compared, relative to that curve. However, one fundamental issue with absolute qPCR is the quantifiable concentration of commercial assay standards can vary depending on (1) origin, i.e., whether from a cell line or a human subject, (2) supplier, (3) lot number, (4) shipping method, etc. In 2018, the National Institute for Standards and Technology (NIST) released a human DNA standard reference material for evaluating qPCR quantification standards, Standard Reference Material (SRM) 2372a, Romsos et al. (2018) [2] which contains three well-characterized human genomic DNA samples: Component A) a single male1 donor, Component B) a single female 1 donor, and Component C) a 1:3 male 2 :female 2 donor, each with certification data for nDNA and informational mitochondrial DNA(mtDNA)/nuclear DNA (nDNA) ratio data. The SRM 2372a was used to assess four qPCR assays: (1) Quantifiler Trio (Thermo Fisher Scientific, Waltham, MA) for nDNA quantification, (2) NovaQUANT (EMD Millipore Corporation, San Diego, CA) for nDNA and mtDNA quantification, (3) a custom duplex mtDNA assay, and (4) a custom triplex mtDNA assay. Additionally, extracts from eighteen (18) skeletal remains were tested with the latter three assays for concordance of DNA concentration and with assays (2) and (3), for the degradation state. Our assessment revealed that an accurate, efficient, and reproducible qPCR assay is dependent on (1) the quality and reliability of the DNA standard, (2) the qPCR chemistry, and (3) the specific primers, and probes (if applicable), used in an assay. Finally, our findings indicate qPCR assays may not always quantify as expected and that performance of each lot should be verified using a well-characterized DNA standard such as the NIST SRM 2372a and adjusted if warranted.

59 BASIC BIOLOGICAL SCIENCES↗

A review on the fatigue behavior of Ti-6Al-4V fabricated by electron beam melting additive manufacturing

Electron beam melting (EBM) is a swiftyly-developing metal additive manufacturing process that holds significant interest in the aerospace and biomedical industries for the high-strength titanium alloy, Ti-6Al-4V. These industries have fatigue-limited applications, yet a lack of understanding of the EBM process-microstructure-fatigue relationships limit widespread use and presents challenges for certification. In this review, uniaxial fatigue data was collected and the effects of build orientation, surface roughness, and hot-isostatic pressing are linked to the fatigue properties highlighting microstructure, defects, and failure mechanisms. The observations and conclusions are supported by statistical analysis using the mean fatigue life obtained by the Statistical Fatigue-Limit Model. Both EBM-process and post-process structure relationships are discussed in order to identify the best-practice for fatigue-resistant design. The performance of the EBM material is compared to conventionally manufactured Ti-6Al-4V and possible methods to increase the fatigue resistance are discussed. Anisotropic fatigue behavior was observed in as-fabricated parts and no statistical distinction was found in the fatigue performance of HIPed and as-fabricated material provided the same as-fabricated rough surface condition. However, comparable fatigue life to traditionally manufactured lamellar Ti-6Al-4V is achieved when both post-process HIP and machining are applied to EBM-fabricated parts.

36 MATERIALS SCIENCE↗

In situ X-ray imaging of pore formation mechanisms and dynamics in laser powder-blown directed energy deposition additive manufacturing

Directed energy deposition (DED) additive manufacturing (AM) is receiving growing attention in many applications, such as repair, remanufacturing, and fabrication of functionally graded structures. However, the laser-matter interactions and melt pool dynamics in laser DED with powder flow are still unclear, particularly in how pores form and flow inside the melt pool during the process. Understanding the porosity formation mechanisms is critical in the qualification, certification, and overall properties of a DED AM part. Porosity is a common phenomenon and can significantly hinder the quality of DED fabricated parts, as the pores can act as sites of crack nucleation and propagation. Here in this paper, we reveal four types of pore formation mechanisms through in-situ and operando high-speed high-resolution X-ray imaging in the DED AM process. Our results confirm that porosity within the feedstock powder induces pores in the process. We also observed pore formation mechanisms unique to the laser-based, powder-blown DED process as a result of powder delivery, keyhole dynamics, melt pool dynamics, and shield gas. High-speed X-ray images provide direct evidence for pore formation mechanisms and show that the pores related to the interaction between the delivered powder and melt pool are the largest in size in laser-based powder-blown DED AM. These results will guide porosity mitigation, elimination, and control in DED AM.

36 MATERIALS SCIENCE↗

Revealing melt flow instabilities in laser powder bed fusion additive manufacturing of aluminum alloy via in-situ high-speed X-ray imaging

Laser metal additive manufacturing technologies enable the fabrication of geometrically and compositionally complex parts unachievable by conventional manufacturing methods. However, the certification and qualification of additively manufactured parts are greatly hindered by the stochastic melt flow instabilities intrinsic to the process, which has not been explicitly revealed by direct observation. Here, we report the mechanisms of the melt flow instabilities in laser powder bed fusion additive manufacturing process revealed by in-situ high-speed high-resolution synchrotron X-ray imaging. Here we identified powder/droplet impact, significant keyhole oscillation, and melting-mode switching as three major mechanisms for causing melt flow instabilities. We demonstrated the detrimental consequences of these instabilities brought to the process, and presented new understanding on the melt flow evolution and keyhole oscillation. This work provides critical insights into process instabilities during laser metal additive manufacturing, which may guide the development of instability mitigation approaches. The results reported here are also important for the development and validation of high-fidelity computational models.

36 MATERIALS SCIENCE↗

Radiation Therapy and Late Mortality From Second Sarcoma, Carcinoma, and Hematological Malignancies After a Solid Cancer in Childhood

Purpose: To compare patterns of long-term deaths due to secondary carcinomas, sarcomas, and hematological malignancies occurring after childhood cancer in a cohort of patients followed over a median of 28 years. Methods and Materials: The study included 4,230 patients treated at eight institutions, who were at least 5-year survivors of a first cancer, representing 105,670 person-years of observation. Complete clinical, chemotherapeutic, and radiotherapeutic data were recorded, and the integral radiation dose was estimated for 2,701 of the 2,948 patients who had received radiotherapy. The integral dose was estimated for the volume inside the beam edges. The causes of death obtained from death certificates were validated. Results: In total, 134 events were due to second malignant neoplasm(s) (SMN). We found that the standardized mortality ratio decreased with increasing follow-up for second carcinomas and sarcomas, whereas the absolute excess risk (AER) increased for a second carcinoma but decreased for second sarcomas. There was no clear variation in SMN and AER for hematological malignancies. We found a significant dose-response relationship between the radiation dose received and the mortality rate due to a second sarcoma and carcinoma. The risk of death due to carcinoma and sarcoma as SMN was 5.2-fold and 12.5-fold higher, respectively, in patients who had received a radiation dose exceeding 150 joules. Conclusions: Among patients who had received radiotherapy, only those having received the highest integral radiation dose actually had a higher risk of dying of a second carcinoma or sarcoma.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fifteen-Year Biochemical Relapse-Free Survival, Cause-Specific Survival, and Overall Survival Following I{sup 125} Prostate Brachytherapy in Clinically Localized Prostate Cancer: Seattle Experience

Purpose: To report 15-year biochemical relapse-free survival (BRFS), cause-specific survival (CSS), and overall survival (OS) outcomes of patients treated with I{sup 125} brachytherapy monotherapy for clinically localized prostate cancer early in the Seattle experience. Methods and Materials: Two hundred fifteen patients with clinically localized prostate cancer were consecutively treated from 1988 to 1992 with I{sup 125} monotherapy. They were prospectively followed as a tight cohort. They were evaluated for BRFS, CSS, and OS. Multivariate analysis was used to evaluate outcomes by pretreatment clinical prognostic factors. BRFS was analyzed by the Phoenix (nadir + 2 ng/mL) definition. CSS and OS were evaluated by chart review, death certificates, and referring physician follow-up notes. Gleason scoring was performed by general pathologists at a community hospital in Seattle. Time to biochemical failure (BF) was calculated and compared by Kaplan-Meier plots. Results: Fifteen-year BRFS for the entire cohort was 80.4%. BRFS by D'Amico risk group classification cohort analysis was 85.9%, 79.9%, and 62.2% for low, intermediate, and high-risk patients, respectively. Follow-up ranged from 3.6 to 18.4 years; median follow-up was 15.4 years for biochemically free of disease patients. Overall median follow-up was 11.7 years. The median time to BF in those who failed was 5.1 years. CSS was 84%. OS was 37.1%. Average age at time of treatment was 70 years. There was no significant difference in BRFS between low and intermediate risk groups. Conclusion: I{sup 125} monotherapy results in excellent 15-year BRFS and CSS, especially when taking into account the era of treatment effect.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Variations in Medicare Reimbursement in Radiation Oncology: An Analysis of the Medicare Provider Utilization and Payment Data Set

Purpose: The purposes of this study were to summarize recently published data on Medicare reimbursement to individual radiation oncologists and to identify the causes of variation in Medicare reimbursement in radiation oncology. Methods and Materials: The Medicare Provider Utilization and Payment Data: Physician and Other Supplier Public Use File (POSPUF), which details nearly all services provided by radiation oncologists in 2012, was used for this study. The data were filtered and analyzed by physician and by billing code. Statistical analysis was performed to identify differences in reimbursements based on sex, rurality, billing of technical services, or location in a certificate of need (CON) state. Results: There were 4135 radiation oncologists who received a total of $1,499,625,803 in payments from Medicare in 2012. Seventy-five percent of radiation oncologists were male. The median reimbursement was $146,453. The code with the highest total reimbursement was 77418 (radiation treatment delivery intensity modulated radiation therapy [IMRT]). The most commonly billed evaluation and management (E/M) code for new visits was 99205 (49%). The most commonly billed E/M code for established visits was 99213 (54%). Forty percent of providers billed none of their new office visits using 99205 (the highest E/M billing code), whereas 34% of providers billed all of their new office visits using 99205. For the 1510 radiation oncologists (37%) who billed technical services, median Medicare reimbursement was $606,008, compared with $93,921 for all other radiation oncologists (P<.001). On multivariate analysis, technical services billing (P<.001), male sex (P<.001), and rural location (P=.007) were predictive of higher Medicare reimbursement. Conclusions: The billing of technical services, with their high capital and labor overhead requirements, limits any comparison in reimbursement between individual radiation oncologists or between radiation oncologists and other specialists. Male sex and rural practice location are independent predictors of higher total Medicare reimbursements.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-precision measurement of U-Pu-Np-Am concentrations and isotope ratios in environmental reference materials by mass spectrometry

Herein, we report results of precise and sensitive mass spectrometric measurements of uranium, plutonium, neptunium, and americium concentrations and isotope ratios in a variety of environmental reference materials. Most of our work has been done on NIST SRM 4350b, River Sediment, but we also present results for NIST SRM 4354, Lake Sediment; NIST SRMs 4355 and 4355a, Peruvian Soil; NIST SRM 4357, Ocean Sediment; NIST SRM 1648a, Urban Particulate Material; NIST SRM 1649b, Urban Dust; IAEA CRM 385, Ocean Sediment; USGS BCR-2, Columbia River Basalt; and USGS BHVO-2, Hawaiian Volcanic Observatory Basalt. These materials reflect a wide range in long-lived actinide concentrations (e.g. 1E4 to 1E10 atoms 239 Pu/g) and isotope ratios. Measurements were performed in a clean laboratory by isotope dilution, multi-collector thermal ionization and multi-collector inductively coupled plasma mass spectrometry. In general, our results are in agreement with, but lower the uncertainty of, literature or certificate values for these reference materials. Our uranium results for the basalts also confirm previously reported high-precision mass spectrometric results from our laboratory. In many cases our measurements of U-Pu-Np-Am nuclides appear to be novel.

58 GEOSCIENCES↗

Effect of threshold parameters on infrared segmentation methods for porosity detection in electron beam powder bed fusion

In-situ process monitoring has seen significant interest in additive manufacturing to address qualification and certification goals. This is especially prevalent in metal powder bed fusion processes such as electron beam powder bed fusion (PBF-EB), with layer-wise infrared imaging being commonly used to detect defects. Here, this work compares two different segmentation methods (static thresholding and statistical thresholding) used for detecting porosity from in-situ infrared imaging data for PBF-EB. Samples were manufactured at a variety of focus offset values to induce porosity. Then, the segmented infrared images were compared to ex-situ X-ray computed tomography scans, which served as a ground-truth reference for objective evaluation. Through this analysis framework, the influential parameters, static threshold and N-value (number of standard deviations above the mean pixel value), respectively, for both image segmentation methods were analyzed and compared for their effects on porosity detection. With optimal parameter settings, the two methods had similar porosity detection performance, but the statistical method performed better under a larger variety of parameter settings.

Infrared imaging↗

Performance and cost of automotive fuel cell systems with ultra-low platinum loadings.

An automotive polymer-electrolyte fuel cell (PEFC) system with ultra-low platinum loading (0.15 mg-Pt cm{sup -2}) has been analyzed to determine the relationship between its design-point efficiency and the system efficiency at part loads, efficiency over drive cycles, stack and system costs, and heat rejection. The membrane electrode assemblies in the reference PEFC stack use nanostructured, thin-film ternary catalysts supported on organic whiskers and a modified perfluorosulfonic acid membrane. The analyses show that the stack Pt content can be reduced by 50% and the projected high-volume manufacturing cost by >45% for the stack and by 25% for the system, if the design-point system efficiency is lowered from 50% to 40%. The resulting penalties in performance are a <1% reduction in the system peak efficiency; a 2-4% decrease in the system efficiency on the urban, highway, and LA92 drive cycles; and a 6.3% decrease in the fuel economy of the modeled hybrid fuel-cell vehicle on the combined cycle used by EPA for emission and fuel economy certification. The stack heat load, however, increases by 50% at full power (80 kW{sub e}) but by only 23% at the continuous power (61.5 kW{sub e}) needed to propel the vehicle on a 6.5% grade at 55 mph. The reduced platinum and system cost advantages of further lowering the design-point efficiency from 40% to 35% are marginal. The analyses indicate that thermal management in the lower efficiency systems is very challenging and that the radiator becomes bulky if the stack temperature cannot be allowed to increase to 90-95 C under driving conditions where heat rejection is difficult.

30 DIRECT ENERGY CONVERSION↗

Neutron residual stress measurement and numerical modeling in a curved thin-walled structure by laser powder bed fusion additive manufacturing

Severe residual stresses in metal parts made by laser powder bed fusion additive manufacturing processes (LPBFAM) can cause both distortion and cracking during the fabrication processes. Limited data is currently available for both iterating through process conditions and design, and in particular, for validating numerical models to accelerate process certification. In this work, residual stresses of a curved thin-walled structure, made of Ni-based superalloy Inconel 625™ and fabricated by LPBFAM, were resolved by neutron diffraction without measuring the stress-free lattices along both the build and the transverse directions. The stresses of the entire part during fabrication and after cooling down were predicted by a simplified layer-by-layer finite element based numerical model. The simulated and measured stresses were found in good quantitative agreement. The validated simplified simulation methodology will allow to assess residual stresses in more complex structures and to significantly reduce manufacturing cycle time.

36 MATERIALS SCIENCE↗

Consistency of vendor-specified activity values for {sup 192}Ir brachytherapy sources

A long-term comparison was done between the manufacturer-stated {sup 192}Ir activity and the measured {sup 192}Ir activities determined with a well-type ionization chamber. Sources for a Nucletron Micro Selectron high-dose-rate (HDR) unit were used for this purpose. The radioactive sources reference activities were determined using a PTW well-type ionization chamber traceable to the National Institute of Standards and Technology Primary Calibration Laboratory. The measurements were taken in a period of 56 months with 17 different radioactive sources. The manufacturer stated activities were taken from the source calibration certificate provided by the manufacturer. These values were compared with the measured activities. The results have shown that both the percentage deviation of the monthly control measurements with the well-type chamber and the ratio between the measured activities to the manufacturer-stated value lie within {+-} 2.5%. These results were compared with similar published data and with uncertainty level (3% of the mean and 5% maximum deviation from mean) for brachytherapy sources calibration recommended by the AAPM. It was concluded that a threshold level of {+-}2.5% can be used as a suitable quality assurance indicator to spot problems in our department. The typical {+-}5% uncertainty as provided by the manufacturers may be tightened to {+-}3% to be more in line with published AAPM reports.

61 RADIATION PROTECTION AND DOSIMETRY↗

Workforce and Salary Survey Trends: Opportunities and Challenges for the American Association of Medical Dosimetrists

The American Association of Medical Dosimetrists (AAMD) designed and directed 2 surveys of the AAMD membership. The first was in 2011 and the second in 2014. There were a number of questions common to both surveys, and this article seeks to evaluate these common questions to determine trends among the professional membership of the AAMD. It is demonstrated that the observed trends are consistent with the goals and objectives established by the leadership of the AAMD and the Medical Dosimetry Certification Board (MDCB) for the medical dosimetry community. In addition, certain challenges and opportunities involving the scope of practice for the medical dosimetry profession are discussed.

61 RADIATION PROTECTION AND DOSIMETRY↗

A database for storing the results of material radiopurity measurements

Searches for rare nuclear processes, such as neutrinoless double beta-decay and the interactions of WIMP dark matter, are motivating experiments with ever-decreasing levels of radioactive backgrounds. These background reductions are achieved using various techniques, but amongst the most important is minimizing radioactive contamination in the materials from which the experiment is constructed. To this end there have been decades of advances in material sourcing, manufacture and certification, during which researchers have accumulated many thousands of measurements of material radiopurity. Some of these assays are described in publications, others are in databases, but many are still communicated informally. Until this work, there has been no standard format for encoding assay results and no effective, central location for storing them. The aim of this paper is to address these long-standing problems by creating a concise and flexible material assay data format and powerful software application to manipulate it. Finally, a public installation of this software, available at http://www.radiopurity.org, is the largest database of assay results ever compiled and is intended as a long-term repository for the community's data.

74 ATOMIC AND MOLECULAR PHYSICS↗

Increasing the detection sensitivity of the Radionuclide Aerosol Sampler/Analyzer using a cosmic veto system

Different configurations of a cosmic veto system have been evaluated for the Radionuclide Aerosol Sampler/Analyzer (RASA). The upgrade has the potential to resolve the issue that U.S. IMS radionuclide stations have difficulty meeting the 140Ba Minimum Detectable Concentration (MDC) certification requirement when the natural background radioactivity is high. It also aims to improve the detection sensitivity of the RASA system for other fission and activation products indicative of a nuclear explosion. This proof of principal utilizes a prototype RASA system located at Pacific Northwest National Laboratory (PNNL), and has demonstrated background reductions by up to 11.3% and improvements in the average MDC by up to 7.7%. Recommendations are made for either a 1 or 3 plate configuration, which improves the 140Ba MDC by 5.6% and 7.2% for a blank filter. Whilst elevated 212Pb activity remains problematic, the cosmic veto system provides a practical solution for sensitivity improvement with little design modification of the RASA. It also has value in improving sensitivity and preventing false-positives at remote U.S. IMS station locations where sample transfer for laboratory analysis is logistically difficult.

Comprehensive Nuclear-Test-Ban Treaty, RASA, Cosmi↗