Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CAVITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Superconducting spoke cavities for high-velocity applications

To date, superconducting spoke cavities have been designed, developed, and tested for particle velocities up to {beta}{sub 0}~0.6, but there is a growing interest in possible applications of multispoke cavities for high-velocity applications. We have explored the design parameter space for low-frequency, high-velocity, double-spoke superconducting cavities in order to determine how each design parameter affects the electromagnetic properties, in particular the surface electromagnetic fields and the shunt impedance. We present detailed design for cavities operating at 325 and 352 MHz and optimized for {beta}{sub 0}~=0.82 and 1.

43 PARTICLE ACCELERATORS↗

High-power tests of a single-cell copper accelerating cavity driven by two input couplers.

High-power tests were conducted on a 350-MHz, single-cell copper accelerating cavity driven simultaneously by two H-loop input couplers for the purpose of determining the reliability, performance, and power-handling capability of the cavity and related components, which have routinely operated at 100-kW power levels. The test was carried out utilizing the APS 350-MHz RF Test Stand, which was modified to split the input rf power into two frac12-power feeds, each supplying power to a separate H-loop coupler on the cavity. Electromagnetic simulations of the two-coupler feed system were used to determine coupler match, peak cavity fields, and the effect of phasing errors between the coupler feed lines. The test was conducted up to a maximum total rf input power of 164-kW CW. Test apparatus details and performance data will be presented.

43 PARTICLE ACCELERATORS↗

Influence of Vane Trailing Edge Flow on the Formation of Cavity Cells and Rim Sealing

Abstract Hot gas ingestion into the turbine rim seal cavity is an important concern for engine designers. To prevent ingestion, rim seals use high-pressure purge flow; however, the penalty is that excessive use of the purge flow decreases engine thermal efficiency. In this paper, a one-stage turbine operating at engine-representative conditions was used to study the effect of steady and time-resolved under-platform cavity temperatures and pressures across a range of coolant flowrates in the presence of vane trailing edge (VTE) flow. This study correlates time-resolved pressure with time-resolved temperature to identify primary frequencies driving ingestion. At certain flowrates, the time-resolved pressures are out of phase with the temperatures, indicating ingestion. Measurements from high-frequency response pressure sensors in the rim seal and vane platform were also used to determine rotational speed and quantity of large-scale structures (cells). In a parallel effort, a computational model using Unsteady Reynolds-averaged Navier–Stokes (URANS) was applied to determine swirl ratio in the rim seal cavity and time-resolved rim sealing effectiveness. The experimental results confirm that at low purge flowrates, the VTE flow influences the unsteady flow field by decreasing pressure unsteadiness in the rim seal cavity. Results show an increase in purge flow increases the number of unsteady large-scale structures in the rim seal and decreases their rotational speed. However, VTE flow was shown to not significantly change the cell speed and count in the rim seal. Simulations point to the importance of the large-scale cell structures in influencing rim sealing unsteadiness, which is not captured in current rim sealing predictive models.

Engineering↗

Deep-learning-based domain adaptation for cavity fault prediction at Jefferson Laboratory

Superconducting radio-frequency (SRF) cavities are the core components of the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab, providing high-power electron beams for nuclear physics experiments. The facility comprises 418 SRF cavities, and any fault in these cavities can lead to interruptions in the electron beam supply. Cavity faults are the leading cause of beam trips in CEBAF. Predicting and mitigating those faults before onset can help maintain normal operation. Existing models face challenges in distinguishing between normal and fault signals when changes occur in the underlying time-series data, from changes in control software, operational parameters, or the environment. This work proposes a deep learning domain adaptation model that leverages transfer learning to address fault prediction challenges by improving accuracy. The model is trained and fine-tuned using a dataset collected for faulty and normal operation using a data acquisition system in CEBAF. Our deep learning-based domain adaptation model achieves a prediction accuracy of 89.61% of the fault and normal signals. The developed model effectively predicts normal running signals compared to the baseline approach without domain adaptation. This capacity is essential for the fault prediction task in the CEBAF because of heavily imbalanced data containing vast amounts of normal signals. The model performs well for predicting faults several hundred milliseconds before the fault onset compared to other models where no adaptation is applied. Incorporating deep learning-based domain adaptation techniques will significantly improve the fault prediction performance.

Rahman, Md Monibor [Old Dominion Univ., Norfolk, V↗

Accuracy of Spencer-Attix cavity theory and calculations of fluence correction factors for the air kerma formalism

EGSnrc calculations of ion chamber response and Spencer-Attix (SA) restricted stopping-power ratios are used to test the assumptions of the SA cavity theory and to assess the accuracy of this theory as it applies to the air kerma formalism for {sup 60}Co beams. Consistent with previous reports, the EGSnrc calculations show that the SA cavity theory, as it is normally applied, requires a correction for the perturbation of the charged particle fluence (K{sub fl}) by the presence of the cavity. The need for K{sub fl} corrections arises from the fact that the standard prescription for choosing the low-energy threshold {Delta} in the SA restricted stopping-power ratio consistently underestimates the values of {Delta} needed if no perturbation to the fluence is assumed. The use of fluence corrections can be avoided by appropriately choosing {Delta}, but it is not clear how {Delta} can be calculated from first principles. Values of {Delta} required to avoid K{sub fl} corrections were found to be consistently higher than {Delta} values obtained using the conventional approach and are also observed to be dependent on the composition of the wall in addition to the cavity size. Values of K{sub fl} have been calculated for many of the graphite-walled ion chambers used by the national metrology institutes around the world and found to be within 0.04% of unity in all cases, with an uncertainty of about 0.02%.

61 RADIATION PROTECTION AND DOSIMETRY↗

Thoracic cavity segmentation algorithm using multiorgan extraction and surface fitting in volumetric CT

Purpose: To develop and validate a semiautomatic segmentation method for thoracic cavity volumetry and mediastinum fat quantification of patients with chronic obstructive pulmonary disease. Methods: The thoracic cavity region was separated by segmenting multiorgans, namely, the rib, lung, heart, and diaphragm. To encompass various lung disease-induced variations, the inner thoracic wall and diaphragm were modeled by using a three-dimensional surface-fitting method. To improve the accuracy of the diaphragm surface model, the heart and its surrounding tissue were segmented by a two-stage level set method using a shape prior. To assess the accuracy of the proposed algorithm, the algorithm results of 50 patients were compared to the manual segmentation results of two experts with more than 5 years of experience (these manual results were confirmed by an expert thoracic radiologist). The proposed method was also compared to three state-of-the-art segmentation methods. The metrics used to evaluate segmentation accuracy were volumetric overlap ratio (VOR), false positive ratio on VOR (FPRV), false negative ratio on VOR (FNRV), average symmetric absolute surface distance (ASASD), average symmetric squared surface distance (ASSSD), and maximum symmetric surface distance (MSSD). Results: In terms of thoracic cavity volumetry, the mean ± SD VOR, FPRV, and FNRV of the proposed method were (98.17 ± 0.84)%, (0.49 ± 0.23)%, and (1.34 ± 0.83)%, respectively. The ASASD, ASSSD, and MSSD for the thoracic wall were 0.28 ± 0.12, 1.28 ± 0.53, and 23.91 ± 7.64 mm, respectively. The ASASD, ASSSD, and MSSD for the diaphragm surface were 1.73 ± 0.91, 3.92 ± 1.68, and 27.80 ± 10.63 mm, respectively. The proposed method performed significantly better than the other three methods in terms of VOR, ASASD, and ASSSD. Conclusions: The proposed semiautomatic thoracic cavity segmentation method, which extracts multiple organs (namely, the rib, thoracic wall, diaphragm, and heart), performed with high accuracy and may be useful for clinical purposes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-180: Fano Cavity Test of Proton Transport in Monte Carlo Codes Running On GPU and Xeon Phi

Purpose: In proton dose calculation, clinically compatible speeds are now achieved with Monte Carlo codes (MC) that combine 1) adequate simplifications in the physics of transport and 2) the use of hardware architectures enabling massive parallel computing (like GPUs). However, the uncertainties related to the transport algorithms used in these codes must be kept minimal. Such algorithms can be checked with the so-called “Fano cavity test”. We implemented the test in two codes that run on specific hardware: gPMC on an nVidia GPU and MCsquare on an Intel Xeon Phi (60 cores). Methods: gPMC and MCsquare are designed for transporting protons in CT geometries. Both codes use the method of fictitious interaction to sample the step-length for each transport step. The considered geometry is a water cavity (2×2×0.2 cm{sup 3}, 0.001 g/cm{sup 3}) in a 10×10×50 cm{sup 3} water phantom (1 g/cm{sup 3}). CPE in the cavity is established by generating protons over the phantom volume with a uniform momentum (energy E) and a uniform intensity per unit mass I. Assuming no nuclear reactions and no generation of other secondaries, the computed cavity dose should equal IE, according to Fano's theorem. Both codes were tested for initial proton energies of 50, 100, and 200 MeV. Results: For all energies, gPMC and MCsquare are within 0.3 and 0.2 % of the theoretical value IE, respectively (0.1% standard deviation). Single-precision computations (instead of double) increased the error by about 0.1% in MCsquare. Conclusion: Despite the simplifications in the physics of transport, both gPMC and MCsquare successfully pass the Fano test. This ensures optimal accuracy of the codes for clinical applications within the uncertainties on the underlying physical models. It also opens the path to other applications of these codes, like the simulation of ion chamber response.

60 APPLIED LIFE SCIENCES↗

SU-E-T-280: Reconstructed Rectal Wall Dose Map-Based Verification of Rectal Dose Sparing Effect According to Rectum Definition Methods and Dose Perturbation by Air Cavity in Endo-Rectal Balloon

Purpose: Dosimetric effect and discrepancy according to the rectum definition methods and dose perturbation by air cavity in an endo-rectal balloon (ERB) were verified using rectal-wall (Rwall) dose maps considering systematic errors in dose optimization and calculation accuracy in intensity-modulated radiation treatment (IMRT) for prostate cancer patients. Methods: When the inflated ERB having average diameter of 4.5 cm and air volume of 100 cc is used for patient, Rwall doses were predicted by pencil-beam convolution (PBC), anisotropic analytic algorithm (AAA), and AcurosXB (AXB) with material assignment function. The errors of dose optimization and calculation by separating air cavity from the whole rectum (Rwhole) were verified with measured rectal doses. The Rwall doses affected by the dose perturbation of air cavity were evaluated using a featured rectal phantom allowing insert of rolled-up gafchromic films and glass rod detectors placed along the rectum perimeter. Inner and outer Rwall doses were verified with reconstructed predicted rectal wall dose maps. Dose errors and extent at dose levels were evaluated with estimated rectal toxicity. Results: While AXB showed insignificant difference of target dose coverage, Rwall doses underestimated by up to 20% in dose optimization for the Rwhole than Rwall at all dose range except for the maximum dose. As dose optimization for Rwall was applied, the Rwall doses presented dose error less than 3% between dose calculation algorithm except for overestimation of maximum rectal dose up to 5% in PBC. Dose optimization for Rwhole caused dose difference of Rwall especially at intermediate doses. Conclusion: Dose optimization for Rwall could be suggested for more accurate prediction of rectal wall dose prediction and dose perturbation effect by air cavity in IMRT for prostate cancer. This research was supported by the Leading Foreign Research Institute Recruitment Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Science, ICT and Future Planning (MSIP) (Grant No. 200900420)

60 APPLIED LIFE SCIENCES↗

SU-E-J-37: Feasibility of Utilizing Carbon Fiducials to Increase Localization Accuracy of Lumpectomy Cavity for Partial Breast Irradiation

Purpose To investigate the feasibility of utilizing carbon fiducials to increase localization accuracy of lumpectomy cavity for partial breast irradiation (PBI). Methods Carbon fiducials were placed intraoperatively in the lumpectomy cavity following resection of breast cancer in 11 patients. The patients were scheduled to receive whole breast irradiation (WBI) with a boost or 3D-conformal PBI. WBI patients were initially setup to skin tattoos using lasers, followed by orthogonal kV on-board-imaging (OBI) matching to bone per clinical practice. Cone beam CT (CBCT) was acquired weekly for offline review. For the boost component of WBI and PBI, patients were setup with lasers, followed by OBI matching to fiducials, with final alignment by CBCT matching to fiducials. Using carbon fiducials as a surrogate for the lumpectomy cavity and CBCT matching to fiducials as the gold standard, setup uncertainties to lasers, OBI bone, OBI fiducials, and CBCT breast were compared. Results Minimal imaging artifacts were introduced by fiducials on the planning CT and CBCT. The fiducials were sufficiently visible on OBI for online localization. The mean magnitude and standard deviation of setup errors were 8.4mm ± 5.3 mm (n=84), 7.3mm ± 3.7mm (n=87), 2.2mm ± 1.6mm (n=40) and 4.8mm ± 2.6mm (n=87), for lasers, OBI bone, OBI fiducials and CBCT breast tissue, respectively. Significant migration occurred in one of 39 implanted fiducials in a patient with a large postoperative seroma. Conclusion OBI carbon fiducial-based setup can improve localization accuracy with minimal imaging artifacts. With increased localization accuracy, setup uncertainties can be reduced from 8mm using OBI bone matching to 3mm using OBI fiducial matching for PBI treatment. This work demonstrates the feasibility of utilizing carbon fiducials to increase localization accuracy to the lumpectomy cavity for PBI. This may be particularly attractive for localization in the setting of proton therapy and other scenarios in which metal clips are contraindicated.

60 APPLIED LIFE SCIENCES↗

SU-E-T-800: Verification of Acurose XB Dose Calculation Algorithm at Air Cavity-Tissue Interface Using Film Measurement for Small Fields of 6-MV Flattening Filter-Free Beams

Purpose: To verify the dose accuracy of Acuros XB (AXB) dose calculation algorithm at air-tissue interface using inhomogeneous phantom for 6-MV flattening filter-free (FFF) beams. Methods: An inhomogeneous phantom included air cavity was manufactured for verifying dose accuracy at the air-tissue interface. The phantom was composed with 1 and 3 cm thickness of air cavity. To evaluate the central axis doses (CAD) and dose profiles of the interface, the dose calculations were performed for 3 × 3 and 4 × 4 cm{sup 2} fields of 6 MV FFF beams with AAA and AXB in Eclipse treatment plainning system. Measurements in this region were performed with Gafchromic film. The root mean square errors (RMSE) were analyzed with calculated and measured dose profile. Dose profiles were divided into inner-dose profile (>80%) and penumbra (20% to 80%) region for evaluating RMSE. To quantify the distribution difference, gamma evaluation was used and determined the agreement with 3%/3mm criteria. Results: The percentage differences (%Diffs) between measured and calculated CAD in the interface, AXB shows more agreement than AAA. The %Diffs were increased with increasing the thickness of air cavity size and it is similar for both algorithms. In RMSEs of inner-profile, AXB was more accurate than AAA. The difference was up to 6 times due to overestimation by AAA. RMSEs of penumbra appeared to high difference for increasing the measurement depth. Gamma agreement also presented that the passing rates decreased in penumbra. Conclusion: This study demonstrated that the dose calculation with AXB shows more accurate than with AAA for the air-tissue interface. The 2D dose distributions with AXB for both inner-profile and penumbra showed better agreement than with AAA relative to variation of the measurement depths and air cavity sizes.

60 APPLIED LIFE SCIENCES↗

Feasibility of a feedback control of atomic self-organization in an optical cavity

Many interesting nonlinear effects are based on the strong interaction of motional degrees of freedom of atoms with an optical cavity field. Among them is the spatial self-organization of atoms in a pattern where the atoms group in either odd or even sites of the cavity-induced optical potential. An experimental observation of this effect can be simplified by using, along with the original cavity-induced feedback, an additional electronic feedback based on the detection of light leaking the cavity and the control of the optical potential for the atoms. Following our previous study, we show that this approach is more efficient from the laser power perspective than the original scheme without the electronic feedback.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Microscopic Theory of Pinning of Multiquantum Vortex in Cylindrical Cavity

We have proposed and developed a microscopic model of depinning (escape) of a multiquantum vortex in a superconductor with a cylindrical nonconducting cavity with the transverse size smaller than or on the order of the superconducting coherence length ξ{sub 0} at zero temperature. The spectrum of subgap quasiparticle excitations in two- and three-quantum vortices trapped by a cylindrical cavity has been calculated in the quasiclassical approximation. It is shown that the transformation of the spectrum is accompanied by break of anomalous spectral branches due to normal reflection of quasiparticles from the surface of a defect. A microscopic (spectral) criterion for multiquantum vortex pinning has been proposed; according to this criterion, the multiquantum vortex can be trapped in the cavity during the formation of a minigap in the elementary excitation spectrum near the Fermi level. Self-consistent calculations of density of states N(r, ε) for two- and three-quantum vortices trapped by a cylindrical cavity of radius on the order of ξ{sub 0} have been performed using quasiclassical Eilenberger equations. In the pure limit and for low temperatures T ≪ T{sub c}, peculiarities observed in the N(r, ε) distribution reflect the presence of M anomalous spectral branches in the M-quantum vortex and confirm the correctness of the spectral criterion of pinning (depinning) of a multiquantum vortex.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fine tuning resonant frequencies for a single cavity defect in three-dimensional layer-by-layer photonic crystal

The resonant frequencies of a single cavity embedded in the three-dimensional layer-by-layer photonic crystal are studied with microwave experiments and transfer-scattering matrix method simulations. The effects of the number of cladding layers and the size of the embedded cavity on resonant frequencies and Q values are carefully examined. The fine increments of cavity size indicate a new pattern of relation between resonant frequencies and cavity sizes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Recovering cavity effects in corrugated organic light emitting diodes

Cavity effects play an important role in determining the out-coupling efficiency of an OLED. By fabricating OLEDs on corrugated substrates, the waveguide and SPP modes can be extracted by diffraction. However, corrugation does not always lead to an enhancement in out-coupling efficiency due to the reduction of the electrode reflectance and hence the cavity effects. Based on the results of our rigorous couple-wave analysis (RCWA) simulation, we found that the cavity effects can be partially recovered using a low index Teflon layer inserted between the ITO anode and the substrate due to the enhancement of the reflectance of the corrugated electrodes. To verify the simulation results, we fabricated corrugated OLEDs having a low-index Teflon interlayer with an EQE of 36%, which is 29% higher than an optimized planar OLED. By experimentally measuring the OLED air mode dispersion, we confirm the cavity emission of a corrugated OLED is enhanced by the low index layer.

36 MATERIALS SCIENCE↗

Sensitive and single-shot OH and temperature measurements by femtosecond cavity-enhanced absorption spectroscopy

In many low-temperature plasmas (LTPs), the OH radical and temperature represent key properties of plasma reactivity. However, OH and temperature measurements in weakly ionized LTPs are challenging, due to the low concentration and short lifetime of OH and the abrupt temperature rise caused by fast gas heating. To address such issues, this Letter combined cavity-enhanced absorption spectroscopy (CEAS) with femtosecond (fs) pulses to enable sensitive single-shot broadband measurements of OH and temperature with a time resolution of ∼180 ns in LTPs. Such a combination leveraged several benefits. With the appropriately designed cavity, an absorption gain of ∼66 was achieved, enhancing the actual OH detection limit by ∼55× to the 10 11 cm -3 level (sub-ppm in this work) compared with single-pass absorption. Single-shot measurements were enabled while maintaining a time resolution of ∼180 ns, sufficiently short for detecting OH with a lifetime of ∼100 μs. With the broadband fs laser, ∼34,000 cavity modes were matched with ∼95 modes matched on each CCD pixel bandwidth, such that fs-CEAS became immune to the laser-cavity coupling noise and highly robust across the entire spectral range. Also, the broadband fs laser allowed simultaneous sensing of many absorption features to enable simultaneous multi-parameter measurements with enhanced accuracies.

Liu, Ning↗

Cavity and Cryomodule Developements for EIC

The EIC is a major new project under construction at BNL in partnership with JLab. It relies upon a number of new SRF cavities at 197 MHz, 394 MHz, 591 MHz and 1773 MHz to pre-bunch, accelerate, cool and crab the stored beams. R&D is focusing on the 591 MHz elliptical cavity and 197 MHz crab cavity first as these are the most challenging. Preliminary designs of these cavities are presented along with an R&D status report. To avoid developing multiple different cryostats a modular approach is adopted using a high degree of commonality of parts and systems. This approach may be easily adapted to other frequencies and applications.

Rimmer, R.A.↗

Direct Observations of Sub-micropulse Electron-beam Effects from Short-range Wakefields in TESLA-type Superconducting RF Cavities

The preservation of the low emittance of electron beams during transport in the accelerating structures of large facilities is an ongoing challenge. In the cases of the TESLA-type superconducting rf cavities currently used in the European X-ray Free-electron Laser (FEL) and the under construction Linac Coherent Light Source upgrade (LCLS-II), off-axis beam transport may result in emittance dilution due to transverse long-range and short-range wakefields (SRW)*. To investigate such effects, experiments were performed at the Fermilab Accelerator Science and Technology (FAST) facility with its unique two-cavity configuration after the photocathode rf gun. We used optical transition radiation (OTR) imaging with a UV-visible synchroscan streak camera to display sub-micropulse y-t effects in the 41-MeV beam. The head-tail transverse kicks within the 11-ps-long micropulses were observed at the 100-micron level for steering off-axis in one cavity and several 100 microns for two cavities. Since the SRW kick angles go inversely with energy, these results may inform the commissioning plans of the LCLS-II injector where beam will be injected at ~1 MeV into a cryomodule.

43 PARTICLE ACCELERATORS↗

THE NEW DESIGN FOR CAPTURE CAVITY OF CEBAF

In CEBAF, the electron beam from the injector must be sufficiently relativistic to match a 1 GeV recirculated beam in the first linac. The electron beam is produced with a ~130 keV electron gun, then accelerated by a room temperature, graded-beta standing wave linac, capture section, from 130 keV to 510 keV before enters two 5-cell superconducting RF cavities for further acceleration. Present capture cavity is a 5-cell side-coupled cavity. We designed a new slot-coupled cavity which has lower power consumption and more compact size.

Wang, Shaoheng↗