Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Biomedical Research”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

SU-G-JeP3-03: Effect of Robot Pose On Beam Blocking for Ultrasound Guided SBRT of the Prostate

Purpose: Ultrasound presents a fast, volumetric image modality for real-time tracking of abdominal organ motion. How-ever, ultrasound transducer placement during radiation therapy is challenging. Recently, approaches using robotic arms for intra-treatment ultrasound imaging have been proposed. Good and reliable imaging requires placing the transducer close to the PTV. We studied the effect of a seven degrees of freedom robot on the fea-sible beam directions. Methods: For five CyberKnife prostate treatment plans we established viewports for the transducer, i.e., points on the patient surface with a soft tissue view towards the PTV. Choosing a feasible transducer pose and using the kinematic redundancy of the KUKA LBR iiwa robot, we considered three robot poses. Poses 1 to 3 had the elbow point anterior, superior, and inferior, respectively. For each pose and each beam starting point, the pro-jections of robot and PTV were computed. We added a 20 mm margin accounting for organ / beam motion. The number of nodes for which the PTV was partially of fully blocked were established. Moreover, the cumula-tive overlap for each of the poses and the minimum overlap over all poses were computed. Results: The fully and partially blocked nodes ranged from 12% to 20% and 13% to 27%, respectively. Typically, pose 3 caused the fewest blocked nodes. The cumulative overlap ranged from 19% to 29%. Taking the minimum overlap, i.e., considering moving the robot’s elbow while maintaining the transducer pose, the cumulative over-lap was reduced to 16% to 18% and was 3% to 6% lower than for the best individual pose. Conclusion: Our results indicate that it is possible to identify feasible ultrasound transducer poses and to use the kinematic redundancy of a 7 DOF robot to minimize the impact of the imaging subsystem on the feasible beam directions for ultrasound guided and motion compensated SBRT. Research partially funded by DFG grants ER 817/1-1 and SCHL 1844/3-1.

60 APPLIED LIFE SCIENCES↗

MO-C-BRB-02: The Physicists’ Leadership Role in Academic Radiology: The Chair’s Perspective

With the profound changes currently occurring in medicine, the role of the medical physicist cannot stagnate, but must evolve to meet the challenges and opportunities that are presented. Medical physicists must understand these changes and establish themselves not only as relevant but as leaders in this new environment. We must increase our presence in clinical settings such as tumor boards, patient rounds, and the development of new diagnosis, imaging, and treatment techniques. By establishing ourselves as competent scientists, we can and must participate in the development of technologies through research, teaching, and clinical implementation. As medical physicists we must define our roles and value to our physician colleagues, patients, referring physicians, and senior administrators. We cannot afford to be viewed solely as quality assurance technologists, but need to move forward in step with medical and practice advances, becoming recognized as having a leadership role in providing quality research, technological development, and quality patient care. In this session, four leaders in medical research and healthcare will discuss their observations on how medical physicists have contributed to advancements in healthcare and opportunities to continue leadership in providing quality medicine through the applications of physics to research, education, and clinical practice. Learning Objectives: Understand the changes in the healthcare environment and how medical physicists can contribute to improving patient care. Learn how medical physicists are currently leading research efforts to improve clinical imaging and diagnosis. Understand the role of medical physicists in developing new technology and leading its translation into clinical care.

60 APPLIED LIFE SCIENCES↗

MO-C-BRB-04: Observations of a Nuclear Radiologist on the Value of the Medical Physicist

With the profound changes currently occurring in medicine, the role of the medical physicist cannot stagnate, but must evolve to meet the challenges and opportunities that are presented. Medical physicists must understand these changes and establish themselves not only as relevant but as leaders in this new environment. We must increase our presence in clinical settings such as tumor boards, patient rounds, and the development of new diagnosis, imaging, and treatment techniques. By establishing ourselves as competent scientists, we can and must participate in the development of technologies through research, teaching, and clinical implementation. As medical physicists we must define our roles and value to our physician colleagues, patients, referring physicians, and senior administrators. We cannot afford to be viewed solely as quality assurance technologists, but need to move forward in step with medical and practice advances, becoming recognized as having a leadership role in providing quality research, technological development, and quality patient care. In this session, four leaders in medical research and healthcare will discuss their observations on how medical physicists have contributed to advancements in healthcare and opportunities to continue leadership in providing quality medicine through the applications of physics to research, education, and clinical practice. Learning Objectives: Understand the changes in the healthcare environment and how medical physicists can contribute to improving patient care. Learn how medical physicists are currently leading research efforts to improve clinical imaging and diagnosis. Understand the role of medical physicists in developing new technology and leading its translation into clinical care.

60 APPLIED LIFE SCIENCES↗

TU-H-BRC-01: A New Fabrication Method for Secondary Skin Collimation Using 3D Scanner and 3D Printer

Purpose: Using secondary skin collimation (SSC) to protect the critical organ surrounding the tumors is always desirable for electron and/or ortho-voltage treatments. However, the time-consuming and labor-intensive fabrication processes of current method (manually fabricate the lead mask) restrict the general use of SSC. The aim of this study is to develop a new SSC fabrication method using 3D scanning and 3D printing technologies in order to largely decrease the human labor involvement and fabrication time, also improve the fabrication accuracy. Methods: First, the patient surface was scanned with a 3D scanner (Structure Sensor, Occipital, CO). The raw scan data was subsequently transferred to a 3D modeling software (Rhinoceros, Ver. 5.0, McNeel North America, Seattle, WA). The tumor contour was then digitized and shielding region was determined by clinicians in the same software. The corresponding SCC conformed to the skin surface was then automatically generated by the software with the proper shielding thickness. The shell of the SCC (with hollow inside) was consequently printed by a 3D printer (Lulzbot TAZ, Aleph Objects, CO) using plastic material. Finally, the hollow mold of SCC was filled up with a melted cerrobend alloy. Once the cerrobend alloy cooled down, the fabrication of SCC was accomplished. Results: The results indicated the proposed method can achieve a much shorter time on making a SCC compared with tradition fabrication method. The processes of making a skin contour model for patients have been eliminated with the new method. SCC created by the new method possessed better accuracy and better conformality to patient’s skin contours. Conclusion: In this study, we have demonstrated a new method for the SCC fabrication. It is anticipated that our method can be an alternative way to replace conventional manual-based methods for electron and/or ortho-voltage SCC fabrication. This research was supported by the Global Ph.D. Fellowship Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Education (Grant No. 2015H1A2A1034071), Republic of Korea.

60 APPLIED LIFE SCIENCES↗

TH-AB-207A-04: Assessment of Patients’ Cumulative Effective Dose From CT Examinations

Purpose: The Joint Commission requires institutions to consider patient’s age and recent imaging exams when deciding on the most appropriate type of imaging exam. Additionally, knowing patient’s imaging history can help prevent duplicate scans. Radiation dose management software affords new opportunities to identify and utilize patients with high cumulative doses as one proxy for subsequent review of imaging history and opportunities in avoiding redundant exams. Methods: Using dose management software (Radimetrics, Bayer Healthcare) a total of 72073 CT examinations performed from Jan 2015 to Jan 2016 were examined to categorize patients with a cumulative effective dose of 100 mSv and above. This threshold was selected based on epidemiological studies on populations exposed to radiation, which demonstrate a statistical increase of cancer risk at doses above 100 mSv. Histories of patients with highest cumulative dose and highest number of exams were further investigated by a Radiologist for appropriateness of recurrent studies and potential opportunities for reduction. Results: Out of 34762 patients, 927 (2.7%) were identified with a cumulative dose of 100 mSv and above. The highest cumulative dose (842 mSv) belonged to an oncology patient who underwent 2 diagnostic exams and 9 interventional ablative CT guided procedures. The patient with highest number of exams (56 counts) and cumulative dose of 170 mSv was a 17 year old trauma patient. An imaging history review of these two patients did not suggest any superfluous scans. Conclusion: Our limited pilot study suggests that recurrent CT exams for patients with oncologic or severe trauma history may be warranted and appropriate. As a result, for future studies we will be focusing on high dose patient cohorts not associated with oncology or severe trauma. Additionally, the review process itself has suggested areas for potential improvement in patient care, including improved documentation and Radiologist involvement in patient management. Dr. McNitt-Gray’s disclosures: Institutional research agreement, Siemens Healthcare; Past recipient, research grant support, Siemens Healthcare; Consultant, Toshiba America Medical Systems; Consultant, Samsung Electronics.

60 APPLIED LIFE SCIENCES↗

Modular space station facilities.

The modular space station will operate as a general purpose laboratory (GPL). In addition, the space station will be able to support many attached or free-flying research and application modules that would be dedicated to specific projects like astronomy or earth observations. The GPL primary functions have been organized into functional laboratories including an electrical/electronics laboratory, a mechanical sciences laboratory, an experiment and test isolation laboratory, a hard data process facility, a data evaluation facility, an optical sciences laboratory, a biomedical and biosciences laboratory, and an experiment/secondary command and control center.

Parker, P. J.↗

Animal models in motion sickness research

Practical information on candidate animal models for motion sickness research and on methods used to elicit and detect motion sickness in these models is provided. Four good potential models for use in motion sickness experiments include the dog, cat, squirrel monkey, and rat. It is concluded that the appropriate use of the animal models, combined with exploitation of state-of-the-art biomedical techniques, should generate a great step forward in the understanding of motion sickness mechanisms and in the development of efficient and effective approaches to its prevention and treatment in humans.

Daunton, Nancy G.↗

X-ray Footprinting at Beamline X28C: A National Resource for Studying Macromolecular Structure and Dynamics

X-ray footprinting employs intense X-rays produced by synchrotron radiation to generate hydroxyl radicals in solution on microseconds-milliseconds timescales. These hydroxyls radicals undergo stable reaction with solvent accessible sites of macromolecule and produce covalent modifications, which are appropriate to probing macromolecule dynamics under physiological condition. For nucleic acids, one analyzes the pattern of fragments after X-ray exposure by gel electrophoresis; the protected sections that are not cleaved yield a 'footprint'. For proteins, the exposed samples are digested with proteases and analyzed by liquid chromatography- and tandem-mass spectrometry to determine the extent and sites of modification. The data provide detailed structural information to map tertiary contacts of macromolecular interactions, which can subsequently be used as constraints for molecular modeling to generate high-resolution structures. This method is unique in providing 'local' structural information in solution for gaining insight into dynamic processes involving, large RNA-protein and protein-protein assemblies on biologically relevant timescales. The method also can uniquely probe the 'local' structure of large complexes poised at equilibrium for functional states of interest, and has been extended to in vivo studies. Beamline X28C is located at the National Synchrotron Light Source of Brookhaven National Laboratory. An expanding set of user groups utilize this national resource funded by the National Institute of Biomedical Imaging and Bioengineering of the National Institutes of Health. The facility is operated by the Center for Synchrotron Biosciences and the Center for Proteomics and Bioinformatics of Case Western Reserve University. The facility supports both onsite and offsite user access. Beam time is allocated online through peer reviewed user proposal system. Examples of recent research projects are provided.

43 PARTICLE ACCELERATORS↗

Routine Production of 89 Zr Using an Automated Module

89 Zr has emerged as a useful radioisotope for targeted molecular imaging via positron emission tomography (PET) in both animal models and humans. This isotope is particularly attractive for cancer research because its half-life (t 1/2 = 3.27 days) is well-suited for in vivo targeting of macromolecules and nanoparticles to cell surface antigens expressed by cancer cells. Furthermore, 89 Zr emits a low-energy positron (E β+,mean = 0.40 MeV), which is favorable for high spatial resolution in PET, with an adequate branching ratio for positron emission (BR = 23%). The demand for 89 Zr for research purposes is increasing; however, 89 Zr also emits significant gamma radiation (Γ 15 keV = 6.6 R∙cm 2 /mCi∙h), which makes producing large amounts of this isotope by hand unrealistic from a radiation safety standpoint. Fortunately, a straightforward method exists for production of 89 Zr by bombarding a natural Y target in a biomedical cyclotron and then separation of 89 Zr from the target material by column chromatography. The chemical separation in this method lends itself to remote processing using an automated module placed inside a hot cell. In this work, we have designed, built and commissioned a module that has performed the chemical separation of 89 Zr safely and routinely, at activities in excess of 50 mCi, with radionuclidic purity > 99.9% and satisfactory effective specific activity (ESA).

07 ISOTOPE AND RADIATION SOURCES↗

Foton-M2 Russian/US Biology Experiments - Development, Implementation, and Operations

The Russian Foton-M2 unmanned research satellite launched from Baikonur, Kazakhstan on May 31, 2005. The satellite was recovered 16 days later in northern Kazakhstan near Kustanay. Prior to this mission, the long history of joint NASA/IMBP research using Russian unmanned spacecraft was in danger of withering due to inactivity. This cooperative history included 9 Bion Russian spaceflights in the period from 1975 to 1997 where NASA had participated first as a guest and finally as a contractual partner. In an effort to reinvigorate this long-standing collaboration, the Institute for Biomedical Problems (IMBP) invited NASA participation in Russian experiments that had been manifested to fly on the Foton-M2 mission.

Ilyin, Eugene A.↗

Advances in metal–organic framework-based hydrogel materials: preparation, properties and applications

Although metal–organic frameworks (MOFs) with intriguing physiochemical properties have recently attracted increasing attention of researchers, MOFs have not adequately achieved various applications due to their instability and unsatisfactory processability. Hence, MOF-based composites as well as structurally novel MOFs have been established to solve this challenge. Recently, some efforts have been made for the development of MOF-based hydrogels. They exhibit excellent properties compared to initial MOFs in many ways (e.g., mechanical strength, absorption capacity and total pore volume). In this review, the up-to-date research progress of MOF-based hydrogels will be briefly summarized. Here, we mainly focus on expounding the classification of MOF-based hydrogels and their related synergistic effects. As to details, we will provide a conspectus of laconic and latest approaches for the synthesis of MOF-based hydrogels, focusing on composite systems, mechanism research, and stability. In addition, the applications of MOF-based hydrogels have been widely discussed, particularly in the environmental, energy and medical aspects. It is hoped that the detailed description of this review can help researchers working on MOF-based hydrogels to develop more novel composite materials and investigate their wider application.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

WE-D-207-00: CT Lung Cancer Screening and the Medical Physicist: Moving Forward

In the United States, Lung Cancer is responsible for more cancer deaths than the next four cancers combined. In addition, the 5 year survival rate for lung cancer patients has not improved over the past 40 to 50 years. To combat this deadly disease, in 2002 the National Cancer Institute launched a very large Randomized Control Trial called the National Lung Screening Trial (NLST). This trial would randomize subjects who had substantial risk of lung cancer (due to age and smoking history) into either a Chest X-ray arm or a low dose CT arm. In November 2010, the National Cancer Institute announced that the NLST had demonstrated 20% fewer lung cancer deaths among those who were screened with low-dose CT than with chest X-ray. In December 2013, the US Preventive Services Task Force recommended the use of Lung Cancer Screening using low dose CT and a little over a year later (Feb. 2015), CMS announced that Medicare would also cover Lung Cancer Screening using low dose CT. Thus private and public insurers are required to provide Lung Cancer Screening programs using CT to the appropriate population(s). The purpose of this Symposium is to inform medical physicists and prepare them to support the implementation of Lung Screening programs. This Symposium will focus on the clinical aspects of lung cancer screening, requirements of a screening registry for systematically capturing and tracking screening patients and results (such as required Medicare data elements) as well as the role of the medical physicist in screening programs, including the development of low dose CT screening protocols. Learning Objectives: To understand the clinical basis and clinical components of a lung cancer screening program, including eligibility criteria and other requirements. To understand the data collection requirements, workflow, and informatics infrastructure needed to support the tracking and reporting components of a screening program. To understand the role of the medical physicist in implementing Lung Cancer Screening protocols for CT, including utilizing resources such as the AAPM Protocols and the ACR Designated Lung Screening Center program. UCLA Department of Radiology has an Institutional research agreement with Siemens Healthcare; Dr. McNitt-Gray has been a recipient of Research Support from Siemens Healthcare in the past. Dr. Aberle has been a Member of Advisory Boards for the LUNGevity Foundation (2011-present) and Siemens Medical Solutions. (2013)

60 APPLIED LIFE SCIENCES↗

SU-C-201-05: Silicon Array Dosimeter in Situ with Electronic Portal Image Device for Simultaneous Transit Dose and Image Verification in Radiotherapy

Purpose: To investigate an Electronic Portal Imaging Device (EPID) coupled to a 2D array dosimeter to provide simultaneous imaging and dose verification. Methods: The novel dual detector configuration comprised of a 2D diode array dosimeter, referred to as a Magic Plate (MP) placed directly on a standard EPID. Dose response of the MP was evaluated by measuring the detector’s response with respect to off-axis position and field size with 30 cm of solid water (SW) acting as a transit object in the beam. Measurements were performed with 3, 5, 10 and 15 mm SW build-up and compared to 2D ionisation chamber array (ICA) measurements and the PinnacleTM treatment planning system (TPS) at a source to detector distance of 150 cm with a 6 MV beam. Clinical dosimetric performance was evaluated by measuring a number of intensity-modulated radiation therapy (IMRT) beams in transit geometry. Imaging performance of the EPID was quantified by measuring the contrast-to-noise ratio (CNR) and spatial resolution. Images of a Rando phantom were used for qualitative assessment. Results: Measured MP off-axis and field size response agreed within 2% of TPS and ICA responses when measured using 15 mm SW build-up. Clinical IMRT beams had gamma pass rates of ≥95% at 3%/3mm criteria. Measured CNR and spatial resolution (f50) were 264.96, 210.6, and 0.41, 0.40 with build-up of 5 and 15 mm respectively for the dual detector configuration. CNR and spatial resolution of 643.9 and 0.41 were measured for standard EPID. CNR was quantitatively worse in the dual detector configuration. Differences in imaging performance were not visible in a qualitative assessment using a Rando phantom. Conclusion: Combining a prototype MP 2D dosimeter with a conventional EPID did not significantly detract from the performance of either device and has the potential for simultaneous on-line patient transit dosimetry and image assessment in radiation therapy. Cancer Institute NSW Australia(Research Equipment Grant 10/REG/1-20) and Cancer Council NSW (Grant ID RG 1-06)

60 APPLIED LIFE SCIENCES↗

SU-F-E-10: Student-Driven Exploration of Radiographic Material Properties, Phantom Construction, and Clinical Workflows Or: The Extraordinary Life of CANDY MAN

Purpose: To develop a hands-on learning experience that explores the radiological and structural properties of everyday items and applies this knowledge to design a simple phantom for radiotherapy exercises. Methods: Students were asked to compile a list of readily available materials thought to have radiation attenuation properties similar to tissues within the human torso. Participants scanned samples of suggested materials and regions of interest (ROIs) were used to characterize bulk attenuation properties. Properties of each material were assessed via comparison to a Gammex Tissue characterization phantom and used to construct a list of inexpensive near-tissue-equivalent materials. Critical discussions focusing on samples found to differ from student expectations were used to revise and narrow the comprehensive list. From their newly acquired knowledge, students designed and constructed a simple thoracic phantom for use in a simulated clinical workflow. Students were tasked with setting up the phantom and acquiring planning CT images for use in treatment planning and dose delivery. Results: Under engineer and physicist supervision, students were trained to use a CT simulator and acquired images for approximately 60 different foodstuffs, candies, and household items. Through peer discussion, students gained valuable insights and were made to review preconceptions about radiographic material properties. From a subset of imaged materials, a simple phantom was successfully designed and constructed to represent a human thorax. Students received hands-on experience with clinical treatment workflows by learning how to perform CT simulation, create a treatment plan for an embedded tumor, align the phantom for treatment, and deliver a treatment fraction. Conclusion: In this activity, students demonstrated their ability to reason through the radiographic material selection process, construct a simple phantom to specifications, and exercise their knowledge of clinical workflows. Furthermore, the enjoyable and inexpensive nature of this project proved to attract participant interest and drive creative exploration. Mahon and Riblett have nothing to disclose; Hugo has a research agreement with Phillips Medical systems, a license agreement with Varian Medical Systems, research grants from the National Institute of Health. Authors do not have any potential conflicts of interest to disclose.

60 APPLIED LIFE SCIENCES↗

TU-FG-201-06: Remote Dosimetric Auditing for Clinical Trials Using EPID Dosimetry: A Pilot Study

Purpose: To perform a pilot study for remote dosimetric credentialing of intensity modulated radiation therapy (IMRT) based clinical trials. The study introduces a novel, time efficient and inexpensive dosimetry audit method for multi-center credentialing. The method employs electronic portal imaging device (EPID) to reconstruct delivered dose inside a virtual flat/cylindrical water phantom. Methods: Five centers, including different accelerator types and treatment planning systems (TPS), were asked to download two CT data sets of a Head and Neck (H&N) and Postprostatectomy (P-P) patients to produce benchmark plans. These were then transferred to virtual flat and cylindrical phantom data sets that were also provided. In-air EPID images of the plans were then acquired, and the data sent to the central site for analysis. At the central site, these were converted to DICOM format, all images were used to reconstruct 2D and 3D dose distributions inside respectively the flat and cylindrical phantoms using inhouse EPID to dose conversion software. 2D dose was calculated for individual fields and 3D dose for the combined fields. The results were compared to corresponding TPS doses. Three gamma criteria were used, 3%3mm-3%/2mm–2%/2mm with a 10% dose threshold, to compare the calculated and prescribed dose. Results: All centers had a high pass rate for the criteria of 3%/3 mm. For 2D dose, the average of centers mean pass rate was 99.6% (SD: 0.3%) and 99.8% (SD: 0.3%) for respectively H&N and PP patients. For 3D dose, 3D gamma was used to compare the model dose with TPS combined dose. The mean pass rate was 97.7% (SD: 2.8%) and 98.3% (SD: 1.6%). Conclusion: Successful performance of the method for the pilot centers establishes the method for dosimetric multi-center credentialing. The results are promising and show a high level of gamma agreement and, the procedure is efficient, consistent and inexpensive. Funding has been provided from Department of Radiation Oncology, TROG Cancer Research and the University of Newcastle. Narges Miri is a recipient of a University of Newcastle postgraduate scholarship.

60 APPLIED LIFE SCIENCES↗

WE-DE-BRA-10: Development of a Novel Scanning Beam Low-Energy Intraoperative Radiation Therapy (SBIORT) System for Pancreatic Cancer

Purpose: Developing a compact collimator system and validating a 3D surface imaging module for a scanning beam low-energy x-ray radiation therapy (SBIORT) system that enables delivery of non-uniform radiation dose to targets with irregular shapes intraoperatively. Methods: SBIORT consists of a low energy x-ray source, a custom compact collimator module, a robotic arm, and a 3D surface imaging module. The 3D surface imaging system (structure sensor) is utilized for treatment planning and motion monitoring of the surgical cavity. SBIORT can deliver non-uniform dose distributions by dynamically moving the x-ray source assembly along optimal paths with various collimator apertures. The compact collimator utilizes a dynamic shutter mechanism to form a variable square aperture. The accuracy and reproducibility of the collimator were evaluated using a high accuracy encoder and a high resolution camera platform. The dosimetrical characteristics of the collimator prototype were evaluated using EBT3 films with a Pantak Therapax unit. The accuracy and clinical feasibility of the 3D imaging system were evaluated using a phantom and a cadaver cavity. Results: The SBIORT collimator has a compact size: 66 mm diameter and 10 mm thickness with the maximum aperture of 20 mm. The mechanical experiment indicated the average accuracy of leaf position was 0.08 mm with a reproducibility of 0.25 mm at 95% confidence level. The dosimetry study indicated the collimator had a penumbra of 0.35 mm with a leaf transmission of 0.5%. 3D surface scans can be acquired in 5 seconds. The average difference between the acquired 3D surface and the ground truth is 1 mm with a standard deviation of 0.6 mm. Conclusion: This work demonstrates the feasibility of the compact collimator and 3D scanning system for the SBIORT. SBIORT is a way of delivering IORT with a compact system that requires minimum shielding of the procedure room. This research is supported by the University of Iowa Internal Funding Initiatives.

60 APPLIED LIFE SCIENCES↗

INCREASING THE TRANSPARENCY AND REPRODUCIBILITY OF SPACE RADIATION SCIENCE: THE RADIATION BIOLOGY ONTOLOGY

Among the primary objectives of the Open/Open-Source Science paradigm are making scientific investigation data transparent and results reproducible [1], objectives shared by the FAIR principles [2]. To accomplish this, the conceptual framework that includes all the investigation objects needs to be accurately captured and communicated to all data consumers. A large part of this requires using metadata standards to annotate data collected. These standards should be readily accessible, informed by scientific community consensus and sufficiently specific to encompass all of the important aspects of the investigation. Starting in 2020 we have been co-leading an open consortium to develop a new metadata standard, the Radiation Biology Ontology (RBO), through the Open Biological and Biomedical Ontologies (OBO) Foundry [3]. We began by transforming many of the terms from the National Council on Radiation Protection and Measurement into concepts that can be formally related to existing OBO Foundry classes or attributes. We then identified and imported into the RBO existing OBO Foundry classes that have obvious relevance for radiation biomedicine (for example, concepts from the Environment Ontology that describe radiative processes, and concepts from the Gene Ontology dealing with molecular and cellular responses to radiation). Finally, we scrutinized datasets from investigations of radiation effects held in NASA GeneLab and LSDA repositories and added additional classes, instances, and attributes into the RBO that should be used to annotate these data. We developed the RBO using the open-source tools of GitHub and publish the RBO periodically through the NIH/NCBI BioPortal website, so systems worldwide can leverage the knowledge it contains [4]. This initial phase of concept modeling has yielded an RBO that at present has more than 300 declared concepts, with more than 3500 additional concepts imported from other OBO Foundry ontologies. While this first phase has focused on concepts for annotating samples, environments, exposures, and measurements, the next phase will center on supporting annotation of results and findings, such as concept models of molecular, cellular and tissue effects. The value of the RBO will be determined in part by our ability to engage the community in its development, and we have established a Radiobiology Informatics Consortium with unrestricted membership as the owner of the RBO in order to encourage investigators, system owners and other to join in this effort. Anyone can report issues or request new concept modeling or other features directly on GitHub. By using the BioPortal application programming interface, systems can pose dynamic queries to the latest version of the RBO for information on individual classes or entire hierarchies; this design eliminates the need for systems to be updated in order to use newer versions of the RBO. We hope to contribute to the advancement of open radiobiological science through the continued, open development of the RBO, that will provide more precise, machine-interpretable descriptions of investigations, as well as support data meta-analysis through machine learning or other artificial intelligence methods. REFERENCES [1] Open science in space. Nature Medicine, 2021. 27(9): p. 1485-1485. [2] Wilkinson, M.D., et al., The FAIR Guiding Principles for scientific data management and stewardship. Sci Data, 2016. 3: p. 160018. [3] Smith, B., et al., The OBO Foundry: coordinated evolution of ontologies to support biomedical data integration. Nat Biotechnol, 2007. 25(11): p. 1251-5. [4] Whetzel, P.L., et al., BioPortal: enhanced functionality via new Web services from the National Center for Biomedical Ontology to access and use ontologies in software applications. Nucleic Acids Res, 2011. 39(Web Server issue): p. W541-5.

informatics↗

Integrated Multiscale Modeling of Molecular Computing Devices

Nanoscience has been one of the major research focuses of the U.S. and much of the world for the past decade, in part because of its promise to revolutionize many fields, including materials, medicine, and electronics. At the heart of this promise is the fact that nanostructured materials can behave radically differently than their macroscopic counterparts (e.g., bulk gold is such an inert metal that it has found applications in such diverse fields as jewelry, biomedical implants and dentistry, whereas gold nanoparticles are highly reactive and are thus useful as nanocatalysts) and have properties that are tunable due to a strong dependence on the size and surface area of the nanostructure. Thus, nanoscience offers a remarkable opportunity to develop new functional systems built around nanostructured materials with unusual and tunable properties and functionality. The transition from nanoscience to nanotechnology becomes possible when nanostructured systems can be made reproducibly by processes that can be implemented on a large scale. The microelectronics industry is one example of an industry that has evolved into the realm of nanotechnology, since the exponential reduction in feature size in computer chips has resulted in feature sizes now under 50nm (45nm in production, 32nm demonstrated; feature size has been going down by a factor of approximately 1/{radical}2 every 18 months as chip density has doubled every 18 months according to Moore's law). Silicon-based microelectronics relies on etching features into a single-crystal silicon substrate by photolithography. As the feature size of silicon-based microelectronics continues to decrease, the continuation of Moore's law to below 20nm feature sizes is being questioned, due to limitations in both the physics of the transistors (leading to unacceptable power dissipation) and doubts about the scalability of top-down photolithography-based manufacturing to such small sizes. There is no doubt that photolithography will some day reach a miniaturization limit, forcing designers of Si-based electronics to pursue increased performance by other means. Any other alternative approach would have the unenviable task of matching the ability of Si technology to pack more than a billion interconnected and addressable devices on a chip the size of a thumbnail. Nevertheless, the prospects of developing alternative approaches to fabricate electronic devices have spurred an ever-increasing pace of fundamental research. One of the promising possibilities is molecular electronics (ME), self-assembled molecular-based electronic systems composed of single-molecule devices in ultra dense, ultra fast molecular-sized components. This project focused on developing accurate, reliable theoretical modeling capabilities for describing molecular electronics devices. The participants in the project are given in Table 1. The primary outcomes of this fundamental computational science grant are publications in the open scientific literature. As listed below, 62 papers have been published from this project. In addition, the research has also been the subject of more than 100 invited talks at conferences, including several plenary or keynote lectures. Many of the goals of the original proposal were completed. Specifically, the multi-disciplinary group developed a unique set of capabilities and tools for investigating electron transport in fabricated and self-assembled nanostructures at multiple length and time scales.

77 NANOSCIENCE AND NANOTECHNOLOGY↗