Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BOOSTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

The SciBooNE Experiment

The SciBar Booster Neutrino Experiment (SciBooNE) is a neutrino scattering experiment located at Fermilab that started to take data in June 2007. The experiment takes advantage of the excellent and well understood SciBar detector from K2K and of the Booster Neutrino Beam from Fermilab. The main SciBooNE goal is to measure the total neutrino and antineutrino cross-sections at low energies with unprecedented statistics. These measurements will help to improve the results of T2K and MiniBooNE neutrino oscillation experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Use of Ionization Electron Columns for Space-Charge Compensation in High Intensity Proton Accelerators

We discuss a recent proposal to use strongly magnetized electron columns created by beam ionization of the residual gas for compensation of space charge forces of high intensity proton beams in synchrotrons and linacs. The electron columns formed by trapped ionization electrons in a longitudinal magnetic field that assures transverse distribution of electron space charge in the column is the same as in the proton beam. Electrostatic electrodes are used to control the accumulation and release of the electrons. Ions are not magnetized and drift away without affecting the compensation. Possible technical solution for the electron columns is presented. We also discuss the first numerical simulation results for space-charge compensation in the FNAL Booster and results of relevant beam studies in the Tevatron.

43 PARTICLE ACCELERATORS↗

Charged-Current Neutral Pion production at SciBooNE

SciBooNE, located in the Booster Neutrino Beam at Fermilab, collected data from June 2007 to August 2008 to accurately measure muon neutrino and anti-neutrino cross sections on carbon below 1 GeV neutrino energy. SciBooNE is studying charged current interactions. Among them, neutral pion production interactions will be the focus of this poster. The experimental signature of neutrino-induced neutral pion production is constituted by two electromagnetic cascades initiated by the conversion of the {pi}{sup 0} decay photons, with an additional muon in the final state for CC processes.In this poster, I will present how we reconstruct and select charged-current muon neutrino interactions producing {pi}{sup 0}'s in SciBooNE.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Status of the ArgoNeuT and MicroBooNE experiments

Liquid Argon (LAr) time projection chambers are a promising technology for future large-scale neutrino detectors. Their spatial resolution and ability to measure dE/dX make them well suited for identifying and measuring the properties of neutrino i nteractions and rejecting background processes. The development of this technology in the United States is taking a staged approach, with current efforts combining research and development and Physics goals in varying amounts. The ArgoNeut experiment, a p rimarily R&D effort, consists of a cryostat containing 0.24 t of LAr. It is currently in the NuMI beam at Fermilab and will take neutrino data this spring. It will provide a test-bed for development of analysis techniques for LAr detectors. The MicroBooNE cryostat will contain 170 t of LAr and will be located in the Booster neutrino beam at Fermilab. MicroBooNE will develop and test processes for building a large LAr detector, as well as make relevant neutrino cross section measurements for future long ba seline neutrino experiments and study the MiniBooNE low energy excess.

Rebel, Brian↗

Optimizing injection for the storage ring proton-EDM experiment

The proposed proton electric dipole moment (pEDM) experiment at Brookhaven National Laboratory (BNL), to be built inside the alternating gradient synchrotron (AGS) tunnel, aims to measure the proton’s electric dipole moment with a sensitivity of 10 −29 𝑒 cm. This paper presents the design of the injection line from the AGS booster to the pEDM storage ring, utilizing portions of the existing booster-to-AGS (BtA) transfer line. Building on the symmetric-hybrid lattice design [, Comprehensive symmetric-hybrid ring design for a proton-EDM experiment at below 10 −29 𝑒 cm, Phys. Rev. D 105, 032001 (2022)], our study emphasizes rigorous optics matching, detailed particle and spin tracking, and systematic error mitigation essential for achieving a target sensitivity of 10 −29 𝑒 cm. This design preserves the proton’s vertical spin orientation within ±20 mrad, a critical requirement for the pEDM measurement. Particle and spin tracking simulations using the ray-tracing code Zgoubi [F. Méot, Zgoubi users’ guide, Technical Report, Brookhaven National Laboratory (BNL), Relativistic Heavy Ion Collider (RHIC), Upton, NY, 2012] validate the design’s performance, demonstrating its feasibility for this precision experiment. The simulation results demonstrate that both clockwise (CW) and counterclockwise (CCW) injection lines meet the stringent beam envelope and polarization requirements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of charged-current muon neutrino-argon interactions without pions in the final state using the MicroBooNE detector

We report a new measurement of flux-integrated differential cross sections for charged-current (CC) muon neutrino interactions with argon nuclei that produce no final-state pions (𝜈 𝜇 ⁢CC⁢0⁢𝜋). These interactions are of particular importance as a topologically defined signal dominated by quasielasticlike interactions. This measurement was performed with the MicroBooNE liquid argon time projection chamber detector located at the Fermilab Booster Neutrino Beam and uses an exposure of 1.3 ×10 21 protons on target collected between 2015 and 2020. The results are presented in terms of single- and double-differential cross sections as a function of the final-state muon momentum and angle. The data are compared with widely used neutrino event generators. We find good agreement with the single-differential measurements, while only a subset of generators are also able to adequately describe the data in double-differential distributions. This work facilitates comparison with Cherenkov detector measurements, including those located at the Booster Neutrino Be

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Preliminary Design Study of a Fast-Ramping Magnet for Pre-Concept Design of an Electron-Ion Collider at Jefferson Lab

The Jefferson Lab Electron Ion Collider (JLEIC) is a proposed new machine for nuclear physics research. The all new ion accelerator and collider complex will consist of two collider rings with a unique figure-of-eight layout to deliver a high degree of polarization in both beams. As part of the pre-concept design for the Ion ring, a 3-Tesla Super-Ferric dipole magnet was proposed utilizing a superconducting Cable-in-Conduit-Conductor (CICC) design to wind the coils which will be built by Texas A&M University. A first mechanical model of the winding for the 3T-SF-CICC dipole was built to validate that the winding structure provides the conductor geometry required to provide collider field homogeneity over large aperture. A rapid-cycling Booster synchrotron is required to inject 8 GeV beams to the Ion Ring. The Booster requires arc dipoles with the same field and aperture as those of the Ion Ring. Due to the design of the CICC with respect to the amount of stabilizer and the internal cooling mechanism employed, temperature rise of the coils during a quench event is much more rapid than for more conventional magnets. It is thus imperative that the magnet?s stored energy is dissipated externally to the windings to avoid overheating the CICC and to provide adequate protection during a quench. As a result, this paper presents a preliminary design study, including AC effects inside the coils and associated risks with the aim of providing guidance for the design of the full protection system for such a magnet.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Waning immunity and IgG4 responses following bivalent mRNA boosting

Messenger RNA (mRNA) vaccines were highly effective against the ancestral SARS-CoV-2 strain, but the efficacy of bivalent mRNA boosters against XBB variants was substantially lower. Here, we show limited durability of neutralizing antibody (NAb) responses against XBB variants and isotype switching to immunoglobulin G4 (IgG4) responses following bivalent mRNA boosting. Bivalent mRNA boosting elicited modest XBB.1-, XBB.1.5-, and XBB.1.16-specific NAbs that waned rapidly within 3 months. In contrast, bivalent mRNA boosting induced more robust and sustained NAbs against the ancestral WA1/2020 strain, suggesting immune imprinting. Following bivalent mRNA boosting, serum antibody responses were primarily IgG2 and IgG4 responses with poor Fc functional activity. In contrast, a third monovalent mRNA immunization boosted all isotypes including IgG1 and IgG3 with robust Fc functional activity. These data show substantial immune imprinting for the ancestral spike and isotype switching to IgG4 responses following bivalent mRNA boosting, with important implications for future booster designs and boosting strategies.

Science & Technology - Other Topics↗

Development of a Bunched Beam Electron Cooler based on ERL and Circulator Ring Technology for the Jefferson Lab Electron-Ion Collider

Jefferson Lab is in the process of designing an electron ion collider with unprecedented luminosity at a 45 GeV center-of-mass energy. This luminosity relies on ion cooling in both the booster and the storage ring of the accelerator complex. The cooling in the booster will use a conventional DC cooler similar to the one at COSY. The high-energy storage ring, operating at a momentum of up to 100 GeV/nucleon, requires novel use of bunched-beam cooling. There are two designs for such a cooler. The first uses a conventional Energy Recovery Linac (ERL) with a magnetized beam while the second uses a circulating ring to enhance both peak and average currents experienced by the ion beam. This presentation will describe the design of both the Circulator Cooling Ring (CCR) design and that of the backup option using the stand-alone ERL operated at lower charge but higher repetition rate than the ERL injector required by the CCR-based design.

Benson, Stephen V.↗

APOLLO: a facility-scale differentiable virtual accelerator at Fermilab FAST/IOTA

As the design complexity of modern accelerators grows, there is more interest in using advanced simulations that have fast execution time or yield additional insights like gradients. The FAST/IOTA facility has been working on implementing and experimentally validating an end-to-end digital twin that is both fast and gradient-aware, allowing for rapid prototyping of new software and experiments with minimal beam time costs. Our framework integrates physics and ML codes for linac and ring simulation through a set of generic interfaces between surrogate and physics-based sections. To reproduce device inputs and outputs, system state is exposed as a deterministic event loop in a specialized discrete event simulator architecture. Because Fermilab is undergoing control system transition, several APIs were implemented as final user interfaces - a fully asynchronous EPICS soft IOC, a gRPC-based Data Pool Manager (DPM), and legacy ACNET protocols. We discuss implementation details as well as challenges handling live data assimilation and future plans to extend modelling to main complex proton accelerators like PIPII and Booster.

Kuklev, Nikita [Fermilab]↗

Development of a bunched beam electron cooler for the Jefferson Lab electron-ion collider

Jefferson Lab is in the process of designing an electron-ion collider with unprecedented luminosity at a 65 GeV center-of-mass energy. This luminosity relies on ion cooling in both the booster and the storage ring of the accelerator complex. The cooling in the booster will use a conventional DC cooler similar to the one at COSY. The high-energy storage ring, operating at a momentum of up to 100 GeV/nucleon, requires novel use of bunched-beam cooling. We will present a new design for a Circulator Cooler Ring for bunched-beam electron cooling. This requires the generation and transport of very high-charge magnetized bunches, acceleration of the bunches in an energy recovery linac, and transfer of these bunches to a circulating ring that passes the bunches 11 times through the proton or ion beam inside cooling solenoids. This design requires the suppression of the effects of space charge and coherent synchrotron radiation using shielding and RF compensation.

Benson, Stephen V.↗

Automating Orbit Correction in the Main Injector 8 GeV Line

The Main Injector 8 GeV line (MI8 line) transports beam from Fermilab's Booster accelerator to either the Booster Neutrino experiments (BNB), the Recycler or the Main Injector. Often the orbit of the beam through the MI8 line differs depending on the beam destination. The beam is collimated in the MI8 line, so increasing intensities and repetition rates make controlling orbits through the collimators a necessity. The current method of regulating the MI8 line orbit with DC corrector settings is insufficient. A system named MITUNE is being developed to sample and categorize all beams through the MI8 line and automatically calculate and apply proper dipole corrector ramps to maintain desired orbits for pulses to any destination.

43 PARTICLE ACCELERATORS↗

Experimental investigation of longitudinal scraping of H- bunches via photo-detachment

Longitudinal emittance growth is a significant challenge in RF linacs, especially for poorly bunched beams. This stems from particles occupying outer synchrotron oscillation orbits in the LBET, causing unwanted bunch-bunch interactions and degraded beam quality. To address this, we proposed using temporally spaced laser pulses to selectively photo-detach electrons from the longitudinal head and tail regions of H- ion bunches. This approach aims to reduce particle density in extreme orbits, enhancing beam uniformity and limiting emittance growth. Our experiments employed Fermilab's 'LaserNotcher' system at the font end of the linac, delivering 1.6 MW peak power with sub-nanosecond precision. By neutralizing the first and last half-nanosecond of several H- bunches, we measured their propagation injection into the booster. Measurements of pulse width, average height, and temporal spacing over booster cycles were compared between the scraped and unscraped bunches. Statistical analysis evaluated the results’ significance, highlighting the feasibility of laser-based scraping for future linac designs to achieve higher beam energies with improved emittance control.

Landon, Parker [Boston U.]↗

CW copper injector for SRF industrial cryomodules

Compact SRF industrial linacs can provide unique parameters of the beam (>1 MW and >1-10 MeV) hardly achievable by normal conducting linacs within limited space. SRF technology was prohibitively expensive until the development of conduction cooling which opened the way for compact stand alone SRF systems suitable for industrial and research applications. Limited cooling capacity puts strict requirements on the beam parameters with zero losses of the beam on the SRF cavity walls. This implies strict requirements on the beam energy to be accepted by the cryomodule and most importantly the beam bunching with zero particles in between. We designed a CW normal conducting RF injector which consists of a gridded RF gun integrated with a first cell of a copper booster cavity to satisfy these requirements. Here we present a complete design of a booster cavity including beam dynamics, RF, thermomechanical and engineering design.

43 PARTICLE ACCELERATORS↗

Design Considerations and Operational Features of the Collimators for the Fermilab Main Injector and Recycler

The Fermilab Main Injector system delivers 700 kW of 120 GeV Proton beam for neutrino experiments. Since 2013 this has been achieved using slip stacking accumulation in the Recycler with up to 12 batches from the Fermilab Booster per Main Injector Ramp Cycle. To control activation from beam loss, collimation systems in the Booster to Recycler transfer line, in the Recycler and in the Main Injector are employed. Residual radiation measurements around the ring with detailed studies at the collimators are required to maintain adequate loss control. We will review design considerations, operational parameters and activation results for more than ten years of operation. Simulations with MARS15 are used to explore the activation rates and the isotopic composition of the resulting activation.

43 PARTICLE ACCELERATORS↗

Benchmarking the Use of BPM Quadrupole Moments to Measure Emittance

For the PIP-II program, transverse emittance in the Fermilab Booster must remain well controlled at higher bunch intensities. 4-plate beam position monitors (BPMs) have a small but measurable quadrupole moment, making it possible to infer transverse emittance. By compositing many BPMs together, it becomes possible to improve the quality of the quadrupole signal. The Fermilab Booster BPM system has been used to measure these quadrupole moments in the past year and derive emittances from them. Recent benchmarks show that the derived BPM emittances show similar emittance evolution and value to IPM and Multiwire data. This approach can both supplement and complement existing non-intercepting emittance monitors in accelerators.

Balcewicz, M. A. [Fermilab]↗

Measurements of the beam longitudinal properties in the Fermilab Linac

The Fermilab Linac delivers 400$\,$MeV, 25$\,$mA H$^-$ beam to a rapid cycling synchrotron called the Booster. Parameters of the Linac beam affect Booster performance and therefore quantifying them is important. The longitudinal bunch parameters are reconstructed using a Bunch Shape Monitor (BSM) installed in the middle of the Linac. For that, the bunch length is measured as a function of the phase of an upstream cavity and fitted to simulations. The cavity gradient and its phase with respect to the beam are recovered from readings of Beam Position Monitors. Since the cavity provides a significant transverse defocusing, the BSM measurements are correlated with transverse beam size measurements by a wire scanner. Simulations connect these three types of measurements, allowing to deduce the longitudinal emittance and Courant-Snyder parameters.

Sharankova, Ralitsa [Fermilab] (ORCID:000000027014↗

Mysterious dipole synchrotron oscillations during and after adiabatic capture

Strong synchrotron oscillations were observed during and after the 2.5-MHz rf adiabatic capture of a debunched booster batch in the Main Injector. Analysis shows two possible sources for the synchrotron oscillations. One is the frequency drift of the 2.5-MHz rf after the turning off of the 53-MHz rf voltage, thus resulting in an energy mismatch with the debunched beam. The second source is the energy mismatch of the injected booster beam with the frequency of the 53-MHz rf. We have been able to rule out the first possibility.

43 PARTICLE ACCELERATORS↗