Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BLOOD VESSELS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Biological Response to SPE Exposures

It has long been recognized that a single solar particle event (SPE) can produce, over a short period of time, exposures on the order of LD50 for humans under normal physiological conditions. It is further recognized that recovery from injury over the period of exposure would greatly increase the chances of survival (dose rate effects) although such effects were left unquantified. In the present report we use the bioresponse model derived from a broad range of animal and human exposure data for evaluation of troop readiness in tactical nuclear warfare to evaluate the biological risk posed by the solar event of 4 August 1972. The astronaut blood forming organ (BFO) exposure in deep space would have been 2.2 Sv (1.6 Gy) in a space suit, 1.8 Sv (1.3 Gy) in an aluminum pressure vessel, and 0.7 Sv (0.5 Gy) in an equipment room compared to an X-ray mortality threshold of 1.5 Gy (assuming high dose rate). We find BFO dose rate effectiveness factors for this SPE on the order of 3 to 4, greatly reducing the mortality risks for this event. There is an approximate 3 percent chance that an even larger event may occur for which exposures could be 2-4 times higher. Assured survival of the astronaut requires added shelter shielding and a warning system for this event. The required mass of the shelter shield can be greatly reduced by using hydrogenous materials such as polymers, water, food, and other biological materials in its construction. Limitations of the current bioresponse model arise from the exposures taking place in the microgravity environment wherein the immune system is already challenged and the effective mortality threshold may be reduced by a factor of two. Such microgravity effects could greatly affect astronaut risks.

Wilson, J. W.↗

Endogenous circulating sympatholytic factor in orthostatic intolerance

Sympathotonic orthostatic hypotension (SOH) is an idiopathic syndrome characterized by tachycardia, hypotension, elevated plasma norepinephrine, and symptoms of orthostatic intolerance provoked by assumption of an upright posture. We studied a woman with severe progressive SOH with blood pressure unresponsive to the pressor effects of alpha(1)-adrenergic receptor (AR) agonists. We tested the hypothesis that a circulating factor in this patient interferes with vascular adrenergic neurotransmission. Preincubation of porcine pulmonary artery vessel rings with patient plasma produced a dose-dependent inhibition of vasoconstriction to phenylephrine in vitro, abolished vasoconstriction to direct electrical stimulation, and had no effect on nonadrenergic vasoconstrictive stimuli (endothelin-1), PGF-2alpha (or KCl). Preincubation of vessels with control plasma was devoid of these effects. SOH plasma inhibited the binding of an alpha(1)-selective antagonist radioligand ([(125)I]HEAT) to membrane fractions derived from porcine pulmonary artery vessel rings, rat liver, and cell lines selectively overexpressing human ARs of the alpha(1B) subtype but not other AR subtypes (alpha(1A) and alpha(1D)). We conclude that a factor in SOH plasma can selectively and irreversibly inhibit adrenergic ligand binding to alpha(1B) ARs. We propose that this factor contributes to a novel pathogenesis for SOH in this patient. This patient's syndrome represents a new disease entity, and her plasma may provide a unique tool for probing the selective functions of alpha(1)-ARs.

Case Reports↗

Superparamagnetic iron oxide polyacrylic acid coated γ-Fe{sub 2}O{sub 3} nanoparticles do not affect kidney function but cause acute effect on the cardiovascular function in healthy mice

This study describes the distribution of intravenously injected polyacrylic acid (PAA) coated γ-Fe{sub 2}O{sub 3} NPs (10 mg kg{sup −1}) at the organ, cellular and subcellular levels in healthy BALB/cJ mice and in parallel addresses the effects of NP injection on kidney function, blood pressure and vascular contractility. Magnetic resonance imaging (MRI) and transmission electron microscopy (TEM) showed accumulation of NPs in the liver within 1 h after intravenous infusion, accommodated by intracellular uptake in endothelial and Kupffer cells with subsequent intracellular uptake in renal cells, particularly the cytoplasm of the proximal tubule, in podocytes and mesangial cells. The renofunctional effects of NPs were evaluated by arterial acid–base status and measurements of glomerular filtration rate (GFR) after instrumentation with chronically indwelling catheters. Arterial pH was 7.46 ± 0.02 and 7.41 ± 0.02 in mice 0.5 h after injections of saline or NP, and did not change over the next 12 h. In addition, the injections of NP did not affect arterial PCO{sub 2} or [HCO{sub 3}{sup −}] either. Twenty-four and 96 h after NP injections, the GFR averaged 0.35 ± 0.04 and 0.35 ± 0.01 ml min{sup −1} g{sup −1}, respectively, values which were statistically comparable with controls (0.29 ± 0.02 and 0.33 ± 0.1 ml{sup –1} min{sup –1} 25 g{sup –1}). Mean arterial blood pressure (MAP) decreased 12–24 h after NP injections (111.1 ± 11.5 vs 123.0 ± 6.1 min{sup −1}) associated with a decreased contractility of small mesenteric arteries revealed by myography to characterize endothelial function. In conclusion, our study demonstrates that accumulation of superparamagnetic iron oxide nanoparticles does not affect kidney function in healthy mice but temporarily decreases blood pressure. -- Highlights: ► PAA coated γ-Fe{sub 2}O{sub 3} nanoparticles were injected intravenously into healthy mice. ► We examine the distribution and physiological effects of nanoparticle accumulation. ► No effects of accumulation in kidney on acid-base status or GFR. ► Acute hypotension associated with decreased contractility of small vessels. ► We demonstrate physiological effects of PAA γ-Fe{sub 2}O{sub 3} NP for medical purposes.

60 APPLIED LIFE SCIENCES↗

Comparative imaging study in ultrasound, MRI, CT, and DSA using a multimodality renal artery phantom

Purpose: A range of anatomically realistic multimodality renal artery phantoms consisting of vessels with varying degrees of stenosis was developed and evaluated using four imaging techniques currently used to detect renal artery stenosis (RAS). The spatial resolution required to visualize vascular geometry and the velocity detection performance required to adequately characterize blood flow in patients suffering from RAS are currently ill-defined, with the result that no one imaging modality has emerged as a gold standard technique for screening for this disease. Methods: The phantoms, which contained a range of stenosis values (0%, 30%, 50%, 70%, and 85%), were designed for use with ultrasound, magnetic resonance imaging, x-ray computed tomography, and x-ray digital subtraction angiography. The construction materials used were optimized with respect to their ultrasonic speed of sound and attenuation coefficient, MR relaxometry (T{sub 1},T{sub 2}) properties, and Hounsfield number/x-ray attenuation coefficient, with a design capable of tolerating high-pressure pulsatile flow. Fiducial targets, incorporated into the phantoms to allow for registration of images among modalities, were chosen to minimize geometric distortions. Results: High quality distortion-free images of the phantoms with good contrast between vessel lumen, fiducial markers, and background tissue to visualize all stenoses were obtained with each modality. Quantitative assessments of the grade of stenosis revealed significant discrepancies between modalities, with each underestimating the stenosis severity for the higher-stenosed phantoms (70% and 85%) by up to 14%, with the greatest discrepancy attributable to DSA. Conclusions: The design and construction of a range of anatomically realistic renal artery phantoms containing varying degrees of stenosis is described. Images obtained using the main four diagnostic techniques used to detect RAS were free from artifacts and exhibited adequate contrast to allow for quantitative measurements of the degree of stenosis in each phantom. Such multimodality phantoms may prove useful in evaluating current and emerging US, MRI, CT, and DSA technology.

60 APPLIED LIFE SCIENCES↗

Fluid dynamics of heart assist device

Certain hemodynamic phenomena that arise in connection with the use of artificial blood pumping devices are reviewed. Among these are: (1) Flows produced by collapsing bulbs; (2) the impedance presented by the aorta; (3) limiting velocities and instability of flow in elastic vessels; (4) effectiveness of valveless arterio-arterial pumps, and (5) wave reflection phenomena and instabilities associated with the intra-aortic balloon pump.

Jones, R. T.↗

Role of a decrease in body heat content in the thermoregulatory reaction of the concha auriculae vessels

At the constant ambient temperature 28-30 C the rabbit ear vessels were dilated and their temperature was 34.8/0.1 C. Administration of the 23-29 C water into the stomach entailed thermoregulatory construction of the ear vessels within 15-25 min. The response occurred at various combinations of temperature changes in different parts of the body. The heat content of the rabbit body, as calculated by the blood temperature in the aorta arc, reduced by 266.3 + or - 26.2 cal/kg at the beginning of the response. The decrease in the organism heat content seems to serve as a signal for occurrence of a corresponding thermoregulatory response.

Slepchuk, N. A.↗

Short term /1 and 3 day/ cardiovascular adjustments to suspension antiorthostasis in rats

Antiorthostasis (AO) results in responses reflective of thoracic vessel loading. Initial findings included fluid and electrolyte shifts (diuresis and natriuresis) in AO but not in orthostatic (O) rats. This study aims at obtaining supportive evidence for cardiovascular responses, E.g., blood pressure and related parameters, in light of the original hypothesis. Tilting rats rapidly head-up from either horizontal (O) or head-down (AO) positions was used to assess cardiovascular sensitivities. O and AO rats were used after 1 or 3 days of suspension. Rats were controls (C), pre-tilted O and AO, tilted O and AO (rapid head-up 70-80 deg); post-tilted (to original postures). MAP in C rats was 108 +2 mmHg, in O, (117 + or - 1.02) and AO, (120 + or - 0.58). MAP, diastolic pressure (DP) and pulse pressure were consistently elevated in AO rats on day 3. With rapid head-up tilt, only MAP and DP showed significant increases. These changes were seen as cardiovascular responses to AO and support further use of this rat model for AO studies.

Musacchia, X. J.↗

Vinpocetine attenuates lipid accumulation and atherosclerosis formation

Highlights: •Vinpocetine attenuates hyperlipidemia-induced atherosclerosis in a mouse model. •Vinpocetine antagonizes ox-LDL uptake and accumulation in macrophages. •Vinpocetine blocks the induction of ox-LDL receptor LOX-1 in vitro and in vivo. -- Abstract: Atherosclerosis, the major cause of myocardial infarction and stroke, is a chronic arterial disease characterized by lipid deposition and inflammation in the vessel wall. Cholesterol, in low-density lipoprotein (LDL), plays a critical role in the pathogenesis of atherosclerosis. Vinpocetine, a derivative of the alkaloid vincamine, has long been used as a cerebral blood flow enhancer for treating cognitive impairment. Recent study indicated that vinpocetine is a potent anti-inflammatory agent. However, its role in the pathogenesis of atherosclerosis remains unexplored. In the present study, we show that vinpocetine significantly reduced atherosclerotic lesion formation in ApoE knockout mice fed with a high-fat diet. In cultured murine macrophage RAW264.7 cells, vinpocetine markedly attenuated oxidized LDL (ox-LDL) uptake and foam cell formation. Moreover, vinpocetine greatly blocked the induction of ox-LDL receptor 1 (LOX-1) in cultured macrophages as well as in the LOX-1 level in atherosclerotic lesions. Taken together, our data reveal a novel role of vinpocetine in reduction of pathogenesis of atherosclerosis, at least partially through suppressing LOX-1 signaling pathway. Given the excellent safety profile of vinpocetine, this study suggests vinpocetine may be a therapeutic candidate for treating atherosclerosis.

60 APPLIED LIFE SCIENCES↗

Cardiac beta-adrenergic receptors and coronary hemodynamics in the conscious dog during hypoxic hypoxia.

The mechanisms by which acute hypoxia (10% and 5% oxygen) mediates changes in coronary blood flow and cardiac function were investigated in the conscious dog. When the dogs breathed hypoxic gas mixtures through a tracheostomy, both arterial and coronary sinus oxygen tensions were significantly decreased. With 5% oxygen, there were significant increases in heart rate (25%), maximum left ventricular dP/dt (39%), left circumflex coronary artery blood flow (163%), and left ventricular oxygen consumption (52%), which were attenuated by beta-adrenergic blockage with propranolol. When electrical pacing was used to keep the ventricular rate constant during hypoxia, there was no significant difference in coronary blood flow before and after beta blockade. Beta-adrenergic receptor activity in the myocardium participates in the integrated response to hypoxia although it may not cause active vasodilation of the coronary vessels.

Erickson, H. H.↗

Is a Swine Model of Arteriovenous Malformation Suitable for Human Extracranial Arteriovenous Malformation? A Preliminary Study

Objective: A chronic arteriovenous malformation (AVM) model using the swine retia mirabilia (RMB) was developed and compared with the human extracranial AVM (EAVM) both in hemodynamics and pathology, to see if this brain AVM model can be used as an EAVM model. Methods: We created an arteriovenous fistula between the common carotid artery and the external jugular vein in eight animals by using end-to-end anastomosis. All animals were sacrificed 1 month after surgery, and the bilateral retia were obtained at autopsy and performed hematoxylin and eosin staining and immunohistochemistry. Pre- and postsurgical hemodynamic evaluations also were conducted. Then, the blood flow and histological changes of the animal model were compared with human EAVM. Results: The angiography after operation showed that the blood flow, like human EAVM, flowed from the feeding artery, via the nidus, drained to the draining vein. Microscopic examination showed dilated lumina and disrupted internal elastic lamina in both RMB of model and nidus of human EAVM, but the thickness of vessel wall had significant difference. Immunohistochemical reactivity for smooth muscle actin, angiopoietin 1, and angiopoietin 2 were similar in chronic model nidus microvessels and human EAVM, whereas vascular endothelial growth factor was significant difference between human EAVM and RMB of model. Conclusions: The AVM model described here is similar to human EAVM in hemodynamics and immunohistochemical features, but there are still some differences in anatomy and pathogenetic mechanism. Further study is needed to evaluate the applicability and efficacy of this model.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of a Multi-Parameter Sensor for Automated, Continuous Cell Culture Monitoring in Bioreactors

Compact and automated sensors are desired for assessing the health of cell cultures in biotechnology experiments in microgravity. Measurement of cell culture medium allows for the optirn.jzation of culture conditions on orbit to maximize cell growth and minimize unnecessary exchange of medium. While several discrete sensors exist to measure culture health, a multi-parameter sensor would simplify the experimental apparatus. One such sensor, the Paratrend 7, consists of three optical fibers for measuring pH, dissolved oxygen (p02), dissolved carbon dioxide (pC02) , and a thermocouple to measure temperature. The sensor bundle was designed for intra-arterial placement in clinical patients, and potentially can be used in NASA's Space Shuttle and International Space Station biotechnology program bioreactors. Methods: A Paratrend 7 sensor was placed at the outlet of a rotating-wall perfused vessel bioreactor system inoculated with BHK-21 (baby hamster kidney) cells. Cell culture medium (GTSF-2, composed of 40% minimum essential medium, 60% L-15 Leibovitz medium) was manually measured using a bench top blood gas analyzer (BGA, Ciba-Corning). Results: A Paratrend 7 sensor was used over a long-term (>120 day) cell culture experiment. The sensor was able to track changes in cell medium pH, p02, and pC02 due to the consumption of nutrients by the BHK-21. When compared to manually obtained BGA measurements, the sensor had good agreement for pH, p02, and pC02 with bias [and precision] of 0.02 [0.15], 1 mm Hg [18 mm Hg], and -4.0 mm Hg [8.0 mm Hg] respectively. The Paratrend oxygen sensor was recalibrated (offset) periodically due to drift. The bias for the raw (no offset or recalibration) oxygen measurements was 42 mm Hg [38 mm Hg]. The measured response (rise) time of the sensor was 20 +/- 4s for pH, 81 +/- 53s for pC02, 51 +/- 20s for p02. For long-term cell culture measurements, these response times are more than adequate. Based on these findings , the Paratrend sensor could offer automated, continuous monitoring of cell cultures with a temporal resolution of 1 minute, which is not attainable by sampling via handheld blood analyzer (i-STAT). Conclusion: The resulting bias and precision found in these cell culture-based studies is comparable to Paratrend sensor clinical results. Although the large error in p02 measurements (+/-18 mm Hg) may be acceptable for clinical applications, where Paratrend values are periodically adjusted to a BGA measurement, the O2 sensor in this bundle may not be reliable enough for the single-calibration requirement of sensors used in NASA's bioreactors. The pH and pC02 sensors in the bundle are reliable and stable over the measurement period, and can be used without recalibration to measure cell cultures in rn.jcrogravity biotechnology experiments. Future work will test additional Paratrend sensors to provide statistical assessment of sensor performance.

Pappas, D.↗

Personalized and uncertainty-aware coronary hemodynamics simulations: From Bayesian estimation to improved multi-fidelity uncertainty quantification

Non-invasive simulations of coronary hemodynamics have improved clinical risk stratification and treatment outcomes for coronary artery disease, compared to relying on anatomical imaging alone. However, simulations typically use empirical approaches to distribute total coronary flow amongst the arteries in the coronary tree, which ignores patient variability, the presence of disease, and other clinical factors. Further, uncertainty in the clinical data often remains unaccounted for in the modeling pipeline. We present an end-to-end uncertainty-aware pipeline to (1) personalize coronary flow simulations by incorporating vessel-specific coronary flows as well as cardiac function; and (2) predict clinical and biomechanical quantities of interest with improved precision, while accounting for uncertainty in the clinical data. We assimilate patient-specific measurements of myocardial blood flow from clinical CT myocardial perfusion imaging to estimate branch-specific coronary artery flows. Simulated noise in the clinical data is used to estimate the joint posterior distributions of the model parameters using adaptive Markov Chain Monte Carlo sampling. Additionally, the posterior predictive distribution for the relevant quantities of interest is determined using a new approach combining multi-fidelity Monte Carlo estimation with non-linear, data-driven dimensionality reduction. This leads to improved correlations between high- and low-fidelity model outputs. Our framework accurately recapitulates clinically measured cardiac function as well as branch-specific coronary flows under measurement noise uncertainty. We observe substantial reductions in confidence intervals for estimated quantities of interest compared to single-fidelity Monte Carlo estimation and state-of-the-art multi-fidelity Monte Carlo methods. This holds especially true for quantities of interest that showed limited correlation between the low- and high-fidelity model predictions. In addition, the proposed multi-fidelity Monte Carlo estimators are significantly cheaper to compute than traditional estimators, under a specified confidence level or variance. The proposed pipeline for personalized and uncertainty-aware predictions of coronary hemodynamics is based on routine clinical measurements and recently developed techniques for CT myocardial perfusion imaging. The proposed pipeline offers significant improvements in precision and reduction in computational cost.

Bayesian parameter estimation↗

Radiation-Induced Astrogliosis and Blood-Brain Barrier Damage Can Be Abrogated Using Anti-TNF Treatment

Purpose: In this article, we investigate the role of tumor necrosis factor-alpha (TNF) in the initiation of acute damage to the blood-brain barrier (BBB) and brain tissue following radiotherapy (RT) for CNS tumors. Methods and Materials: Intravital microscopy and a closed cranial window technique were used to measure quantitatively BBB permeability to FITC-dextran 4.4-kDa molecules, leukocyte adhesion (Rhodamine-6G) and vessel diameters before and after 20-Gy cranial radiation with and without treatment with anti-TNF. Immunohistochemistry was used to quantify astrogliosis post-RT and immunofluorescence was used to visualize protein expression of TNF and ICAM-1 post-RT. Recombinant TNF (rTNF) was used to elucidate the role of TNF in leukocyte adhesion and vessel diameter. Results: Mice treated with anti-TNF showed significantly lower permeability and leukocyte adhesion at 24 and 48 h post-RT vs. RT-only animals. We observed a significant decrease in arteriole diameters at 48 h post-RT that was inhibited in TNF-treated animals. We also saw a significant increase in activated astrocytes following RT that was significantly lower in the anti-TNF-treated group. In addition, immunofluorescence showed protein expression of TNF and ICAM-1 in the cerebral cortex that was inhibited with anti-TNF treatment. Finally, administration of rTNF induced a decrease in arteriole diameter and a significant increase in leukocyte adhesion in venules and arterioles. Conclusions: TNF plays a significant role in acute changes in BBB permeability, leukocyte adhesion, arteriole diameter, and astrocyte activation following cranial radiation. Treatment with anti-TNF protects the brain's microvascular network from the acute damage following RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Media Compositions for Three-Dimensional Mammalian Tissue Growth under Microgravity Culture Conditions

Normal mammalian tissue and the culturing process has been developed for the three groups of organ, structural and blood tissue.The cells are grown in vitro under microgravity culture conditions and form three dimensional cells aggregates with normal cell function. The microgravity culture conditions may be microgravity or simulated microgravity created in a horizontal rotating wall culture vessel.

Goodwin, Thomas J.↗

Atherosclerotic changes of vessels caused by restriction of movement

The effect of restriction of movement on the development of atheroscelerosis was studied in rabbits. Drastic restriction of movement for 20 and 30 days causes atherosclerotic alterations of the aorta and shifts in ECG which are characteristic of coronary atherosclerosis. At the same time, shortening of the duration of blood coagulation and an increase in the content of catecholamines and beta-lipoproteids occur.

Gvishiani, G. S.↗

Cultured normal mammalian tissue and process

Normal mammalian tissue and the culturing process has been developed for the three groups of organ, structural and blood tissue. The cells are grown in vitro under microgravity culture conditions and form three dimensional cell aggregates with normal cell function. The microgravity culture conditions may be microgravity or simulated microgravity created in a horizontal rotating wall culture vessel.

Goodwin, Thomas J.↗

Method for Producing Non-Neoplastic, Three Dimensional, Mammalian Tissue and Cell Aggregates Under Microgravity Culture Conditions and the Products Produced Therefrom

Normal mammalian tissue and the culturing process has been developed for the three groups of organ, structural, and blood tissue. The cells are grown in vitro under microgravity culture conditions and form three dimensional cells aggregates with normal cell function. The microgravity culture conditions may be microgravity or simulated microgravity created in a horizontal rotating wall culture vessel.

Goodwin, Thomas J.↗

Media Compositions for Three Dimensional Mammalian Tissue Growth Under Microgravity Culture Conditions

Normal mammalian tissue and the culturing process has been developed for the three groups of organ, structural and blood tissue. The cells are grown in vitro under microgravity culture conditions and form three dimensional cells aggregates with normal cell function. The microgravity culture conditions may be microgravity or simulated microgravity created in a horizontal rotating wall culture vessel.

Goodwin, Thomas J.↗