Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BACKGROUND RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Imaging spectroscopy diagnosis of internal electron temperature and density distributions of plasma cloud surrounding hydrogen pellet in the Large Helical Device

To investigate the behavior of hydrogen pellet ablation, a novel method of high-speed imaging spectroscopy has been used in the Large Helical Device (LHD) for identifying the internal distribution of the electron density and temperature of the plasma cloud surrounding the pellet. This spectroscopic system consists of a five-branch fiberscope and a fast camera, with each objective lens having a different narrow-band optical filter for the hydrogen Balmer lines and the background continuum radiation. The electron density and temperature in the plasma cloud are obtained, with a spatial resolution of about 6 mm and a temporal resolution of 5 Multiplication-Sign 10{sup -5} s, from the intensity ratio measured through these filters. To verify the imaging, the average electron density and temperature also have been measured from the total emission by using a photodiode, showing that both density and temperature increase with time during the pellet ablation. The electron density distribution ranging from 10{sup 22} to 10{sup 24} m{sup -3} and the temperature distribution around 1 eV have been observed via imaging. The electron density and temperature of a 0.1 m plasma cloud are distributed along the magnetic field lines and a significant electron pressure forms in the plasma cloud for typical experimental conditions of the LHD.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of low radioactivity background in a high voltage cable by high resolution inductively coupled plasma mass spectrometry

The measurement of naturally occurring low level radioactivity background in a high voltage (HV) cable by high resolution inductively coupled plasma mass spectrometry (HR ICP MS) is presented in this work. The measurements were performed at the Chemistry Service of the Gran Sasso National Laboratory. The contributions to the radioactive background coming from the different components of the heterogeneous material were separated. Based on the mass fraction of the cable, the whole contamination was calculated. The HR ICP MS results were cross-checked by gamma ray spectroscopy analysis that was performed at the low background facility STELLA (Sub Terranean Low Level Assay) of the LNGS underground lab using HPGe detectors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Background studies for NaI(Tl) detectors in the ANAIS dark matter project

Several large NaI(Tl) detectors, produced by different companies, have been operated in the Canfranc Underground Laboratory (LSC) in the frame of the ANAIS (Annual modulation with NaI Scintillators) project devoted to the direct detection of dark matter. A complete background model has been developed for a 9.6 kg detector (referred as ANAIS-0 prototype) after a long data taking at LSC. Activities from the natural chains of {sup 238}U and {sup 232}Th, and {sup 40}K in the NaI(Tl) crystal were evaluated applying different methods: discrimination of alpha particles vs beta/gamma background by Pulse Shape Analysis for quantifying the content of the natural chains and coincidence techniques for {sup 40}K. Radioactive contaminations in the detector and shielding components were also determined by HPGe spectrometry. Monte Carlo simulations using Geant4 package were carried out to evaluate their contribution. At high energies, most of the measured background is nicely reproduced; at low energy some non-explained components are still present, although some plausible background sources have been analyzed. The {sup 40}K content of the NaI(Tl) crystal has been confirmed to be the dominant contributor to the measured background with this detector. In addition, preliminary results of the background characterization, presently underway at the LSC, of two recently produced NaI(Tl) detectors, with 12.5 kg mass each, will be presented: cosmogenic induced activity has been clearly observed and is being quantified, and {sup 40}K activity at a level ten times lower than in ANAIS-0 has been determined.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Review of Monte Carlo simulations for backgrounds from radioactivity

For all experiments dealing with the rare event searches (neutrino, dark matter, neutrino-less double-beta decay), the reduction of the radioactive background is one of the most important and difficult tasks. There are basically two types of background, electron recoils and nuclear recoils. The electron recoil background is mostly from the gamma rays through the radioactive decay. The nuclear recoil background is from neutrons from spontaneous fission, (α, n) reactions and muoninduced interactions (spallations, photo-nuclear and hadronic interaction). The external gammas and neutrons from the muons and laboratory environment, can be reduced by operating the detector at deep underground laboratories and by placing active or passive shield materials around the detector. The radioactivity of the detector materials also contributes to the background; in order to reduce it a careful screening campaign is mandatory to select highly radio-pure materials. In this review I present the status of current Monte Carlo simulations aimed to estimate and reproduce the background induced by gamma and neutron radioactivity of the materials and the shield of rare event search experiment. For the electromagnetic background a good level of agreement between the data and the MC simulation has been reached by the XENON100 and EDELWEISS experiments, using the GEANT4 toolkit. For the neutron background, a comparison between the yield of neutrons from spontaneous fission and (α, n) obtained with two dedicated softwares, SOURCES-4A and the one developed by Mei-Zhang-Hime, show a good overall agreement, with total yields within a factor 2 difference. The energy spectra from SOURCES-4A are in general smoother, while those from MZH presents sharp peaks. The neutron propagation through various materials has been studied with two MC codes, GEANT4 and MCNPX, showing a reasonably good agreement, inside 50% discrepancy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling surface backgrounds from radon progeny plate-out

The next generation low-background detectors operating deep underground aim for unprecedented low levels of radioactive backgrounds. The surface deposition and subsequent implantation of radon progeny in detector materials will be a source of energetic background events. We investigate Monte Carlo and model-based simulations to understand the surface implantation profile of radon progeny. Depending on the material and region of interest of a rare event search, these partial energy depositions can be problematic. Motivated by the use of Ge crystals for the detection of neutrinoless double-beta decay, we wish to understand the detector response of surface backgrounds from radon progeny. We look at the simulation of surface decays using a validated implantation distribution based on nuclear recoils and a realistic surface texture. Results of the simulations and measured α spectra are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of low background CsI(Tl) and NaI(Tl) crystals for WIMP search

We have developed low background CsI(Tl) and NaI(Tl) crystals to search for weakly interacting massive particles as well as to verify the origin of the annual modulation signal observed by the DAMA/LIBRA experiment. Extensive studies about the contamination mechanisim of {sup 137}Cs in CsI powder lead to the growth of ultra-low-background CsI(Tl) crystals. Similar approaches for NaI(Tl) crystals have been applied to reduce internal backgrounds to less than 0.5 counts/kg/day/keV. Status and understanding of backgrounds and background reduction in NaI(Tl) crystals will be discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Low background techniques in CANDLES

CANDLES is a double beta decay experiment using {sup 48}Ca in CaF{sub 2} crystals. The measurement is being performed with prototype detector (CANDLES III) for high sensitive measurement in the future. Recent status of detector improvements and background reduction techniques are described in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Production and relevance of cosmogenic radionuclides in NaI(Tl) crystals

The cosmogenic production of long-lived radioactive isotopes in materials is an hazard for experiments demanding ultra-low background conditions. Although NaI(Tl) scintillators have been used in this context for a long time, very few activation data were available. We present results from two 12.5 kg NaI(Tl) detectors, developed within the ANAIS project and installed at the Canfranc Underground Laboratory. The prompt data taking starting made possible a reliable quantification of production of some I, Te and Na isotopes with half-lives larger than ten days. Tnitial activities underground were measured and then production rates at sea level were estimated following the history of detectors; a comparison of these rates with calculations using typical cosmic neutron flux at sea level and a selected description of excitation functions was also carried out. After including the contribution from the identified cosmogenic products in the detector background model, we found that the presence of {sup 3}H in the crystal bulk would help to fit much better our background model and experimental data. We have analyzed the cosmogenic production of {sup 3}H in NaI, and although precise quantification has not been attempted, we can conclude that it could imply a very relevant contribution to the total background below 15 ke in NaI detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gamma ray imager on the DIII-D tokamak

A gamma ray camera is built for the DIII-D tokamak [J. Luxon, Nucl. Fusion 42, 614 (2002)] that provides spatial localization and energy resolution of gamma flux by combining a lead pinhole camera with custom-built detectors and optimized viewing geometry. This diagnostic system is installed on the outer midplane of the tokamak such that its 123 collimated sightlines extend across the tokamak radius while also covering most of the vertical extent of the plasma volume. A set of 30 bismuth germanate detectors can be secured in any of the available sightlines, allowing for customizable coverage in experiments with runaway electrons in the energy range of 1–60 MeV. Commissioning of the gamma ray imager includes the quantification of electromagnetic noise sources in the tokamak machine hall and a measurement of the energy spectrum of background gamma radiation. First measurements of gamma rays coming from the plasma provide a suitable testbed for implementing pulse height analysis that provides the energy of detected gamma photons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

miniTimeCube as a neutron scatter camera

We present Monte Carlo (MC) simulation results from a study of a compact plastic-scintillator detector suitable for imaging fast neutrons in the 1 – 10 MeV energy range: the miniTimeCube (mTC). Originally designed for antineutrino detection, the mTC consists of 24 MultiChannel Plate (MCP) photodetectors surrounding a 13 cm cube of boron-doped plastic scintillator. Our simulation results show that waveform digitization of 1536 optically sensitive channels surrounding the scintillator should allow for spatiotemporal determination of individual neutron-proton scatters in the detector volume to ~ 100 picoseconds and ~5 mm. A Bayesian estimation framework is presented for multiple-scatter reconstruction, and is used to estimate the incoming direction and energy of simulated individual neutrons. Finally, we show how populations of reconstructed neutrons can be used to estimate the direction and energy spectrum of nearby simulated neutron sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Response of CR-39 nuclear track detectors to protons with non-normal incidence

This paper presents data from experiments with protons at non-normal incidence to CR-39 nuclear track detectors, analyzing the properties of detection efficiency, proton track diameter, track contrast, and track eccentricity. Understanding the CR-39 response to protons incident at an angle is important for designing charged particle detectors for inertial confinement fusion (ICF) applications. This study considers protons with incident energies less than 3 MeV. In this regime, an incident angle of 10° has no effect on CR-39 detection efficiency, and >85% detection efficiency is preserved up through 25° in the range of 1.0 MeV–2.1 MeV. For ICF applications, incident angles above 30° are deemed impractical for detector design due to significant drops in proton detection at all energies. We observe significant reductions in detection efficiency compared to theoretical predictions, particularly at low energies where proton tracks are etched away. The proton track diameter measured by the scan system is observed to decrease with higher incident angles. The track diameters are analyzed with two fitting models, and it is shown that the diameter–energy relation can be fit with the existing models at angles up to 30° . The optical contrast of the tracks tends to increase with the angle, meaning that the tracks are fainter, and a larger increase is observed for higher energies. Eccentricity, a measure of how elongated proton tracks are, increases with the incident angle and drops after the critical angle. The lowest energy tracks remain nearly circular even at higher angles.

47 OTHER INSTRUMENTATION↗

Measurement of early time outer laser beam reflection inside a cylindrical hohlraum at the National Ignition Facility

In a National Ignition Facility (NIF) cylindrical hohlraum, any specular reflection (“glint”) off the wall from the outer cone (incident angle of 50° and 44° relative to the surface of the wall) laser beam will irradiate the capsule poles. If the glint power is sufficiently large during the picket (early time) of the laser pulse, it may seed high-mode perturbations on the capsule surface that can grow during the implosion. To quantify the glint power on the capsule during the picket by the outer beams, we performed dedicated experiments on NIF using a flat witness foil as a surrogate for the capsule in a half-hohlraum target. We found that the measured glint power is approximately comparable to simulations using a nominal electron conduction flux limiter of f = 0.15, and over an order of magnitude lower than that predicted using f = 0.03 in the wall. Based on our current understanding, we conclude that the glint from the outer beams plays an insignificant role in capsule drive asymmetry.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SEARCH FOR THE SUNYAEV-ZEL'DOVICH EFFECT IN A GIANT RADIO GALAXY B1358+305

We present results of an imaging observation of the central region of a giant radio galaxy B1358+305. The classical, standard scenario of Fanaroff-Riley II radio galaxies suggests that shock-produced hot electrons contained in a radio galaxy are a good reservoir of the jet-supplied energy from active nuclei. The aim of our observation is to search for the Sunyaev-Zel'dovich effect (SZE) induced by these hot electrons. The observation was performed at 21 GHz with the Nobeyama 45 m telescope. Deep imaging observation of a wide region of size 6.'7 x 6.'7 with the beam size {theta}{sub HPBW} = 81.''2 enables the most detailed examination of the possible thermal energy of electrons contained in a radio galaxy. The resultant intensity fluctuation is 0.56 mJy beam{sup -1} (in terms of the Compton y-parameter, y = 1.04 x 10{sup -4}) at a 95% confidence level. The intensity fluctuation obtained with imaging analysis sets the most stringent upper limit on the fluctuations in the central region of a giant radio galaxy obtained so far, and our results will be a toehold for future plans of SZE observation in a radio galaxy.

79 ASTRONOMY AND ASTROPHYSICS↗

FITTING THE UNION2.1 SUPERNOVA SAMPLE WITH THE R{sub h} = ct UNIVERSE

The analysis of Type Ia supernova data over the past decade has been a notable success story in cosmology. These standard candles offer us an unparalleled opportunity to study the cosmological expansion out to a redshift of {approx}1.5. The consensus today appears to be that {Lambda}CDM offers the best explanation for the luminosity-distance relationship seen in these events. However, a significant incompatibility is now emerging between the standard model and other equally important observations, such as those of the cosmic microwave background. {Lambda}CDM does not provide an accurate representation of the cosmological expansion at high redshifts (z >> 2). It is therefore essential to re-analyze the Type Ia supernova data in light of the cosmology (the R{sub h} = ct universe) that best represents the universe's dynamical evolution at early times. In this paper, we directly compare the distance relationship in {Lambda}CDM with that predicted by R{sub h} = ct, and each with the Union2.1 sample, and show that the two theories produce virtually indistinguishable profiles, though the fit with R{sub h} = ct has not yet been optimized. This is because the data cannot be determined independently of the assumed cosmology-the supernova luminosities must be evaluated by optimizing four parameters simultaneously with those in the adopted model. This renders the data compliant to the underlying theory, so the model-dependent data reduction should not be ignored in any comparative analysis between competing cosmologies. In this paper, we use R{sub h} = ct to fit the data reduced with {Lambda}CDM, and though quite promising, the match is not perfect. An even better fit would result with an optimization of the data using R{sub h} = ct from the beginning.

79 ASTRONOMY AND ASTROPHYSICS↗

Cosmological implications of the CMB large-scale structure

The Wilkinson Microwave Anisotropy Probe (WMAP) and Planck may have uncovered several anomalies in the full cosmic microwave background (CMB) sky that could indicate possible new physics driving the growth of density fluctuations in the early universe. These include an unusually low power at the largest scales and an apparent alignment of the quadrupole and octopole moments. In a ΛCDM model where the CMB is described by a Gaussian Random Field, the quadrupole and octopole moments should be statistically independent. The emergence of these low probability features may simply be due to posterior selections from many such possible effects, whose occurrence would therefore not be as unlikely as one might naively infer. If this is not the case, however, and if these features are not due to effects such as foreground contamination, their combined statistical significance would be equal to the product of their individual significances. In the absence of such extraneous factors, and ignoring the biasing due to posterior selection, the missing large-angle correlations would have a probability as low as ∼0.1% and the low-l multipole alignment would be unlikely at the ∼4.9% level; under the least favorable conditions, their simultaneous observation in the context of the standard model could then be likely at only the ∼0.005% level. In this paper, we explore the possibility that these features are indeed anomalous, and show that the corresponding probability of CMB multipole alignment in the R{sub h}=ct universe would then be ∼7–10%, depending on the number of large-scale Sachs–Wolfe induced fluctuations. Since the low power at the largest spatial scales is reproduced in this cosmology without the need to invoke cosmic variance, the overall likelihood of observing both of these features in the CMB is ⩾7%, much more likely than in ΛCDM, if the anomalies are real. The key physical ingredient responsible for this difference is the existence in the former of a maximum fluctuation size at the time of recombination, which is absent in the latter because of inflation.

79 ASTRONOMY AND ASTROPHYSICS↗

A COMPARATIVE ANALYSIS OF THE SUPERNOVA LEGACY SURVEY SAMPLE WITH ΛCDM AND THE R{sub h}=ct UNIVERSE

The use of Type Ia supernovae (SNe Ia) has thus far produced the most reliable measurement of the expansion history of the universe, suggesting that ΛCDM offers the best explanation for the redshift–luminosity distribution observed in these events. However, analysis of other kinds of sources, such as cosmic chronometers, gamma-ray bursts, and high-z quasars, conflicts with this conclusion, indicating instead that the constant expansion rate implied by the R{sub h} = ct universe is a better fit to the data. The central difficulty with the use of SNe Ia as standard candles is that one must optimize three or four nuisance parameters characterizing supernova (SN) luminosities simultaneously with the parameters of an expansion model. Hence, in comparing competing models, one must reduce the data independently for each. We carry out such a comparison of ΛCDM and the R{sub h} = ct universe using the SN Legacy Survey sample of 252 SN events, and show that each model fits its individually reduced data very well. However, since R{sub h} = ct has only one free parameter (the Hubble constant), it follows from a standard model selection technique that it is to be preferred over ΛCDM, the minimalist version of which has three (the Hubble constant, the scaled matter density, and either the spatial curvature constant or the dark energy equation-of-state parameter). We estimate using the Bayes Information Criterion that in a pairwise comparison, the likelihood of R{sub h} = ct is ∼90%, compared with only ∼10% for a minimalist form of ΛCDM, in which dark energy is simply a cosmological constant. Compared to R{sub h} = ct, versions of the standard model with more elaborate parametrizations of dark energy are judged to be even less likely.

79 ASTRONOMY AND ASTROPHYSICS↗