Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ACOUSTIC MONITORING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

rHealth One Demonstration Aboard ISS: A Microfluidic Bioanalyzer Based on Sheath/Hydrodynamic Focusing Flow Cytometry

The Exploration Medical Capability (ExMC) element aims to provide astronauts with the means for their own health monitoring, diagnosis, and treatment during exploration missions. As space flight ventures further from earth, the need for autonomous medical care increases under greater constraints on size, mass, and resources. One pillar for diagnosis that crew would be separated from is laboratory analysis. Even now on ISS, blood samples must be collected and returned to earth for testing. In response, ExMC is assessing how assays for hematology, bone health, radiation exposure etc. could be addressed through commercial-off-the-shelf (COTS) and Small Business Innovation Research (SBIR) funded bioanalyzers that are miniaturizing lab technology. Since missions will reach distances where there are no timely replacements, validation on the International Space Station (ISS) is a necessary part of that assessment. In partnership with NASA Johnson Space Center (JSC) Immunology Lab and the Research Operations and Integration (ROI) element, ExMC conducted a technology demonstration on ISS of the rHEALTH ONE, a flow cytometry based bioanalyzer, to assess future devices based on this design. In flow cytometry, there are predominantly three ways to focus the cells (or particles) into a single file stream: hydrodynamic focusing, microcapillary, and acoustic focusing. The rHEALTH ONE utilizes the commercial standard, sheath-based hydrodynamic focusing. rHEALTH itself represents both a company and a suite of medical tools NASA has funded through SBIR grants towards the development of a promising diagnosis instrument for exploration missions. rHEALTH ONE is the interim version of the technology, functional as a benchtop analyzer and test bed for the next generation of rHEALTH in development. Several modifications were made to the rHEALTH ONE analyzer for operation in microgravity. For function, fluid management was key. A sheath-based analyzer uses sheath fluid to flow the sample, cleaning fluid to prevent biological contamination, and a reservoir to collect the liquid waste. The rHEALTH ONE analyzer uses bottles dependent on gravity to separate the air and liquid pathways and keep the liquids contained. It uses only 1 psig of air pressure to directly push the liquid through the device, requiring little-to-no resistance at inlet and outlet. A microtubing assembly with self-sealing luer connectors was designed – featuring 0.014 mm thick durable medical balloons to hold water inside the supply bottles – to create safe containment and easy access for the crew while maintaining the analyzer’s function. For safety, copper tape was added to the interior of the plastic housing to reduce electromagnetic interference, fluid and electrical connections were secured against vibration and leaks, and gaps were further sealed to ensure containment of the optical block and lasers. Water as the sheath and cleaning fluid and TOX 0 samples were used to reduce the biohazard risk to the crew. In May 2022, European Space Agency astronaut Samantha Cristoforetti demonstrated the rHEALTH ONE aboard ISS for its sample loading, flow cytometry, and data collection capability in microgravity. The JSC Immunology Lab provided flow cytometry expertise, designed the sample test protocol, and manufactured and benchmarked the flight samples on a ‘gold-standard’ flow cytometer. The analyzer was primed with water, purged of air, and four calibration solutions of polystyrene microparticles were tested to characterize its performance. Tightly controlled procedures and excellent execution prevented air bubble interference during air/water separation, fluid transfer, sample mixing and loading. Data showed a slight increase in signal noise on 3 of 5 channels and an anomaly of fluorophores migrating in one sample (confirmed by JSC post-flight). Flight results correctly detected the change in sample, matched the analyzer’s ground performance, and were consistent with the gold-standard’s ground results. Although areas were noted for improvement, these outcomes signified complete mission success.

R. S. Miller↗

Multimodal sensor fusion for real-time standoff estimation in directed energy deposition

In Laser Powder-based Direct Energy Deposition (LP-DED) systems, achieving consistency, precision and quality of produced parts requires tight control over printing parameters. One of the critical parameters is the standoff distance. Maintaining an optimal standoff height is crucial for achieving correct laser power density and powder catchment efficiency, as both laser and powder streams are focused at this distance. Here, this study introduces a novel approach using multimodal sensor fusion to predict standoff height in real-time. The proposed system integrates two low-profile, cost-effective sensors: an RGB coaxial camera and a high frequency and high dynamic range microphone. By utilizing a simple fully connected neural network, trained on a limited dataset, data fusion of these sensors allowed for the real-time prediction of the standoff height. The results demonstrate high resolution and accuracy of the predictions across multiple geometries and a wide range of standoff heights. This approach offers a simple, and cost-effective solution for real-time standoff height monitoring and lays the groundwork for future integration into commercial LP-DED systems.

42 ENGINEERING↗

Comparison of Surface Phenomena Created by Underground Chemical Explosions in Dry Alluvium and Granite Geology From Fully Polarimetric VideoSAR Data

Phase I of the Source Physics Experiment (SPE) series involved six underground chemical explosions, all of which were conducted at the same experimental pad. Research from the sixth explosion of the series (SPE-6) demonstrated that polarimetric synthetic aperture radar (PolSAR) is a viable technology for monitoring an underground chemical explosion when the geologic structure is Cretaceous granitic intrusive. It was shown that a durable signal is measurable by the H/A/α polarimetric decomposition parameters. After the SPE-6 experiment, the SPE program moved to the Phase II location, which is composed of dry alluvium geology (DAG). The loss of wavefront energy is greater through dry alluvium than through granite. In this article, we compare the SPE-6 analysis to the second DAG (DAG-2) experiment. We hypothesize that despite the geology at the DAG site being more challenging than at the Phase I location, combined with the DAG-2 experiment having a 3.37 times deeper scaled depth of burial than the SPE-6, a durable nonprompt signal is still measurable by a PolSAR sensor. We compare the PolSAR time-series measures from videoSAR frames, from the SPE-6 and DAG-2 experiments, with accelerometer data. We show which PolSAR measures are invariant to the two types of geology and which are geology dependent. We compare a coherent change detection (CCD) map from the DAG-2 experiment with the data from a fiber-optic distributed acoustic sensor to show the connection between the spatial extent of coherence loss in CCD maps and spallation caused by the explosion. Finally, we also analyze the spatial extent of the PolSAR measures from both explosions.

42 ENGINEERING↗

Attention Network Forecasts Time-to-Failure in Laboratory Shear Experiments

Rocks under stress deform by creep mechanisms that include formation and slip on small-scale internal cracks. Intragranular cracks and slip along grain contacts release energy as elastic waves termed acoustic emissions (AE). AEs are thought to contain predictive information that can be used for fault failure forecasting. Here, we present a method using unsupervised classification and an attention network to forecast labquakes using AE waveform features. Our data were generated in a laboratory setting using a biaxial shearing device with granular fault gouge intended to mimic the conditions of tectonic faults. Here, we analyzed the temporal evolution of AEs generated throughout several hundred laboratory earthquake cycles. We used a Conscience Self-Organizing Map (CSOM) to perform topologically ordered vector quantization based on waveform properties. The resulting map was used to interactively cluster AEs. We examined the clusters over time to identify those with predictive ability. Finally, we used a variety of LSTM and attention-based networks to test the predictive power of the AE clusters. By tracking cumulative waveform features over the seismic cycle, the network is able to forecast the time-to-failure (TTF) of lab earthquakes. Our results show that analyzing the data to isolate predictive signals and using a more sophisticated network architecture are key to robustly forecasting labquakes. In the future, this method could be applied on tectonic faults to monitor earthquakes and augment early warning systems.

58 GEOSCIENCES↗

Fractionated Stereotactic Radiotherapy in the Treatment of Vestibular Schwannoma (Acoustic Neuroma): Predicting the Risk of Hydrocephalus;Vestibular schwannoma; Hydrocephalus; Fractionated; Stereotactic radiotherapy

Purpose: To determine the incidence and predictive factors for the development of hydrocephalus in patients with acoustic neuromas (AN) treated with fractionated stereotactic radiotherapy. Patients and Methods: Seventy-two patients with AN were treated with fractionated stereotactic radiotherapy between 1998 and 2007 (45-50 Gy in 25-30 fractions over 5 to 6 weeks). The pretreatment MRI scan was assessed for tumor characteristics and anatomic distortion independently of subsequent outcome and correlated with the risk of hydrocephalus. Results: At a median follow-up of 49 months (range, 1-120 months), 5-year event-free survival was 95%. Eight patients (11%) developed hydrocephalus within 19 months of radiotherapy, which was successfully treated. On univariate analysis, pretreatment factors predictive of hydrocephalus were maximum diameter (p = 0.005), proximity to midline (p = 0.009), displacement of the fourth ventricle (p = 0.02), partial effacement of the fourth ventricle (p < 0.001), contact with the medulla (p = 0.005), and more brainstem structures (p = 0.004). On multivariate analysis, after adjusting for fourth ventricular effacement, no other variables remained independently associated with hydrocephalus formation. Conclusions: Fractionated stereotactic radiotherapy results in excellent tumor control of AN, albeit with a risk of developing hydrocephalus. Patients at high risk, identified as those with larger tumors with partial effacement of the fourth ventricle before treatment, should be monitored more closely during follow-up. It would also be preferable to offer treatment to patients with progressive AN while the risk of hydrocephalus is low, before the development of marked distortion of fourth ventricle before tumor diameter significantly exceeds 2 cm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development and Test of High Temperature Surface Acoustic Wave Gas Sensors

The demand for sensors in hostile environments, such as power plant environments, aerospace environments, oil and gas extraction, and high-temperature metallurgy environments, has risen over the past decades in a continuous attempt to increase process control, improve energy and process efficiency in production, reduce operational and maintenance costs, increase safety, and perform condition-based maintenance in equipment and structures operating in high-temperature harsh-environment conditions. The increased reliability, improved performance, and development of new sensors and networks with a multitude of components, especially wireless networks, are the target for operation in harsh environments. Gas sensors, in particular H2 sensors, operating above 200 C are required in the instrumentation, process control and general safety of a number of industries including coal, natural gas, and nuclear power generation facilities, the aerospace and automotive industries, metallurgical production and defense-related applications. The surface acoustic wave (SAW) platform is a particularly promising option for high-temperature, harsh-environment gas sensing applications since the platform exhibits advantages, such as battery-free and wireless operation, small size, possibility for scale production using well-developed technologies from the semiconductor industry, and low cost of installation and operation. In this work, one-port SAW resonators (SAWRs) operating along five different orientations on a commercially available langasite (LGS) wafer employing Pt-Al2O3 electrodes and reflectors were designed, fabricated, and used as high-temperature H2 sensors. Two of the selected orientations were predicted and confirmed to have temperature-compensated operation above 150 C. A gas sensor test setup was developed, capable of gas cycling between N2, O2 and N2/H2 mixtures under extended high-temperature periods (up to 650 C for over 20 hours). Thin film Pt-Al2O3 was used as the electrode material for the transducers and reflectors capable of high-temperature operation, and also as H2 sensing film. In addition, yttria-stabilized zirconia (YSZ) thin films with Pt decoration were tested as sensing films aimed to enhance the SAWR sensor response to H2. The SAW devices were monitored in excess of 1700 hours in real-time during gas cycling sequences up to 600 C, leading to the following findings: i) the Pt-Al2O3 electrodes performed better for H2 sensing than the Pt-decorated YSZ sensing film, showing as much as 50% higher frequency variation response in the 200 C to 400 C range; ii) different crystallographic orientations operating on the same LGS wafer experienced different responses to H2 exposures up to 500 C; iii) the surface oxidation state of the SAWR sensors was shown to have an important impact on subsequent H2 exposure responses. In addition, a sensor system employing two LGS SAWRs, aligned along two different orientations, has been developed to simultaneously determine H2 presence and temperature. Finally, wireless interrogation of a SAWR sensor was successful within the gas cycling test fixture, and successful wireless H2 detection was achieved above 400 C.

Ayes Moncada, Armando↗

Modeling Concept and Numerical Simulation of Ultrasonic Wave Propagation in a Moving Fluid-Structure Domain based on a Monolithic Approach

Here in the present study, we propose a novel multiphysics model that merges two time-dependent problems – the Fluid-Structure Interaction (FSI) and the ultrasonic wave propagation in a fluid-structure domain with a one directional coupling from the FSI problem to the ultrasonic wave propagation problem. This model is referred to as the “eXtended fluid-structure interaction (eXFSI)” problem. This model comprises isothermal, incompressible Navier-Stokes equations with nonlinear elastodynamics using the Saint-Venant Kirchhoff solid model. The ultrasonic wave propagation problem comprises monolithically coupled acoustic and elastic wave equations. To ensure that the fluid and structure domains are conforming, we use the ALE technique. The solution principle for the coupled problem is to first solve the FSI problem and then to solve the wave propagation problem. Accordingly, the boundary conditions for the wave propagation problem are automatically adopted from the FSI problem at each time step. The overall problem is highly nonlinear, which is tackled via a Newton-like method. The model is verified using several alternative domain configurations. To ensure the credibility of the modeling approach, the numerical solution is contrasted against experimental data.

97 MATHEMATICS AND COMPUTING↗

Joint physics-based and data-driven time-lapse seismic inversion: Mitigating data scarcity

In carbon capture and sequestration (CCS), developing rapid and effective imaging techniques is crucial for real-time monitoring of the spatial and temporal dynamics of CO 2 propagation during/after injection. With continuing improvements in computational power and data storage, data-driven techniques based on machine learning (ML) have been effectively applied to seismic inverse problems. In particular, ML helps alleviate the ill-posedness and high computational cost of full-waveform inversion (FWI). However, such data-driven inversion techniques require massive high-quality training data sets to ensure prediction accuracy, which hinders their application to time-lapse monitoring of CO 2 sequestration. We propose an efficient “hybrid” time-lapse workflow that combines physics-based FWI and data-driven ML inversion. The scarcity of the available training data is addressed by developing a new data-generation technique with physics constraints. The method is vali dated on a synthetic CO 2 -sequestration model based on the Kimberlina storage reservoir in California. The proposed approach is shown to synthesize a large volume of high-quality, physically realistic training data, which is critically important in accurately characterizing the CO 2 movement in the reservoir. In conclusion, the developed hybrid methodology can also simultaneously predict the variations in velocity and saturation and achieve high spatial resolution in the presence of realistic noise in the data.

58 GEOSCIENCES↗

Acoustoelastic lamb wave propagation in a homogeneous, isotropic aluminum plate

The effect of stress on Lamb wave propagation is relevant to both nondestructive evaluation and structural health monitoring because of changes in received signals due to both the associated strain and the acoustoelastic effect. A homogeneous plate that is initially isotropic becomes anisotropic under uniaxial stress, and dispersion of propagating waves becomes directionally dependent. The problem is similar to Lamb wave propagation in an anisotropic plate, except the fourth order tensor in the resulting wave equation does not have the same symmetry as that for the unstressed anisotropic plate, and the constitutive equation relating incremental stress to incremental strain is more complicated. Here we consider the theory of acoustoelastic Lamb wave propagation and show how dispersion curves shift anisotropically for an aluminum plate under uniaxial tension. Theoretical predictions of changes in phase velocity as a function of propagation direction are compared to experimental results for a single wave mode.

42 ENGINEERING↗

Noninvasive Detection, Tracking, and Characterization of Aerogel Implants Using Diagnostic Ultrasound

Medical implants are routinely tracked and monitored using different techniques, such as MRI, X-ray, and ultrasound. Due to the need for ionizing radiation, the two former methods pose a significant risk to tissue. Ultrasound imaging, however, is non-invasive and presents no known risk to human tissue. Aerogels are an emerging material with great potential in biomedical implants. While qualitative observation of ultrasound images by experts can already provide a lot of information about the implants and the surrounding structures, this paper describes the development and study of two simple B-Mode image analysis techniques based on attenuation measurements and echogenicity comparisons, which can further enhance the study of the biological tissues and implants, especially of different types of biocompatible aerogels.

36 MATERIALS SCIENCE↗

Wideband Single-Crystal Transducer for Bone Characterization

The microgravity conditions of space travel result in unique physiological demands on the human body. In particular, the absence of the continual mechanical stresses on the skeletal system that are present on Earth cause the bones to decalcify. Trabecular structure decreases in thickness and increases in spacing, resulting in decreased bone strength and increased risk of injury. Thus, monitoring bone health is a high priority for long-term space travel. A single probe covering all frequency bands of interest would be ideal for such measurements, and this would also minimize storage space and eliminate the complexity of integrating multiple probes. This invention is an ultrasound transducer for the structural characterization of bone. Such characterization measures features of reflected and transmitted ultrasound signals, and correlates these signals with bone structure metrics such as bone mineral density, trabecular spacing, and thickness, etc. The techniques used to determine these various metrics require measurements over a broad range of ultrasound frequencies, and therefore, complete characterization requires the use of several narrowband transducers. This is a single transducer capable of making these measurements in all the required frequency bands. The device achieves this capability through a unique combination of a broadband piezoelectric material; a design incorporating multiple resonator sizes with distinct, overlapping frequency spectra; and a micromachining process for producing the multiple-resonator pattern with common electrode surfaces between the resonators. This device consists of a pattern of resonator bars with common electrodes that is wrapped around a central mandrel such that the radiating faces of the resonators are coplanar and can be simultaneously applied to the sample to be measured. The device operates as both a source and receiver of acoustic energy. It is operated by connection to an electronic system capable of both providing an excitation signal to the transducer and amplifying the signal received from the transducer. The excitation signal may be either a wide-bandwidth signal to excite the transducer across its entire operational spectrum, or a narrow-bandwidth signal optimized for a particular measurement technique. The transducer face is applied to the skin covering the bone to be characterized, and may be operated in through-transmission mode using two transducers, or in pulse-echo mode. The transducer is a unique combination of material, design, and fabrication technique. It is based on single-crystal lead magnesium niobate lead titanate (PMN-PT) piezoelectric material. As compared to the commonly used piezoceramics, this piezocrystal has superior piezoelectric and elastic properties, which results in devices with superior bandwidth, source level, and power requirements. This design necessitates a single resonant frequency. However, by operating in a transverse length-extensional mode, with the electric field applied orthogonally to the extensional direction, resonators of different sizes can share common electrodes, resulting in a multiply-resonant structure. With carefully sized resonators, and the superior bandwidth of piezocrystal, the resonances can be made to overlap to form a smooth, wide-bandwidth characteristic.

Liang, Yu↗

Wideband Single-Crystal Transducer for Bone Characterization

The microgravity conditions of space travel result in unique physiological demands on the human body. In particular, the absence of the continual mechanical stresses on the skeletal system that are present on Earth cause the bones to decalcify. Trabecular structure decreases in thickness and increases in spacing, resulting in decreased bone strength and increased risk of injury. Thus, monitoring bone health is a high priority for long-term space travel. A single probe covering all frequency bands of interest would be ideal for such measurements, and this would also minimize storage space and eliminate the complexity of integrating multiple probes. This invention is an ultrasound transducer for the structural characterization of bone. Such characterization measures features of reflected and transmitted ultrasound signals, and correlates these signals with bone structure metrics such as bone mineral density, trabecular spacing, and thickness, etc. The techniques used to determine these various metrics require measurements over a broad range of ultrasound frequencies, and therefore, complete characterization requires the use of several narrowband transducers. This is a single transducer capable of making these measurements in all the required frequency bands. The device achieves this capability through a unique combination of a broadband piezoelectric material; a design incorporating multiple resonator sizes with distinct, overlapping frequency spectra; and a micromachining process for producing the multiple-resonator pattern with common electrode surfaces between the resonators. This device consists of a pattern of resonator bars with common electrodes that is wrapped around a central mandrel such that the radiating faces of the resonators are coplanar and can be simultaneously applied to the sample to be measured. The device operates as both a source and receiver of acoustic energy. It is operated by connection to an electronic system capable of both providing an excitation signal to the transducer and amplifying the signal received from the transducer. The excitation signal may be either a wide-bandwidth signal to excite the transducer across its entire operational spectrum, or a narrow-bandwidth signal optimized for a particular measurement technique. The transducer face is applied to the skin covering the bone to be characterized, and may be operated in through transmission mode using two transducers, or in pulse-echo mode.

Liang, Yu↗

Airframe Noise Results from the QTD II Flight Test Program

With continued growth in air travel, sensitivity to community noise intensifies and materializes in the form of increased monitoring, regulations, and restrictions. Accordingly, realization of quieter aircraft is imperative, albeit only achievable with reduction of both engine and airframe components of total aircraft noise. Model-scale airframe noise testing has aided in this pursuit; however, the results are somewhat limited due to lack of fidelity of model hardware, particularly in simulating full-scale landing gear. Moreover, simulation of true in-flight conditions is non-trivial if not infeasible. This paper reports on an investigation of full-scale landing gear noise measured as part of the 2005 Quiet Technology Demonstrator 2 (QTD2) flight test program. Conventional Boeing 777-300ER main landing gear were tested, along with two noise reduction concepts, namely a toboggan fairing and gear alignment with the local flow, both of which were down-selected from various other noise reduction devices evaluated in model-scale testing at Virginia Tech. The full-scale toboggan fairings were designed by Goodrich Aerostructures as add-on devices allowing for complete retraction of the main gear. The baseline-conventional gear, faired gear, and aligned gear were all evaluated with the high-lift system in the retracted position and deployed at various flap settings, all at engine idle power setting. Measurements were taken with flyover community noise microphones and a large aperture acoustic phased array, yielding far-field spectra, and localized sources (beamform maps). The results were utilized to evaluate qualitatively and quantitatively the merit of each noise reduction concept. Complete similarity between model-scale and full-scale noise reduction levels was not found and requires further investigation. Far-field spectra exhibited no noise reduction for both concepts across all angles and frequencies. Phased array beamform maps show inconclusive evidence of noise reduction at selective frequencies (1500 to 3000 Hz) but are otherwise in general agreement with the far-field spectra results (within measurement uncertainty).

Elkoby, Ronen↗

Biological Data for Deep Space Mission Support

Increased biomedical risks and challenges associated with deep space missions (cis-Lunar, Mars transit, Mars surface) require new knowledge discovery and development of novel ecosystem and biomedical support capabilities. This paradigm shift supporting distant and long-duration missions requires biological data to be findable, accessible, interoperable, reusable (FAIR), and maximally open-access (i.e., there is a data governance continuum from closed to mediated to embargoed to open). The NASA “Open Science Data Repositories” (OSDR) aims to meet scientific, technical, and operational spaceflight needs, and offers the ability to upload, download, search, share, analyze, and visualize data across physiological, behavioral, ‘omics, and environmental monitoring telemetry datasets. OSDR includes NASA GeneLab, NASA Ames Life Sciences Data Archive (ALSDA), and NASA Biological Institutional Scientific Collection (NBISC). In the past year, ALSDA has undergone a transformation in its data collection, curation, and architecture methods. Standardizing non-genomic (phenotypic) datasets was, and will continue to be, a challenge because of their diverse nature (e.g., molecular, cellular, tissue, whole organism behavior; micro-computed tomography, intraocular pressure, fluorescence microscopy, western blot, ultrasonography; tabular, images, video). This year ALSDA, alongside GeneLab, introduced the Biological Data Management Environment (BDME) with the purpose to accept submission of data from space relevant experiments including spaceflight, radiation, simulated gravity, gravitropism, isolation and confinement, hostile closed environments and/or distance from Earth. In addition to bringing together omics, phenotypic, physiological, bioimaging, and behavioral data into one repository. By integrating with GeneLab a multi-project submission portal aims to reduce the burden on PIs submitting data and enabling the discovery of both omics and phenotypic data. The purpose of ALSDA is to collect, curate, and make all non-human space-relevant biological data maximally findable, accessible, interoperable, and reusable (FAIR). These scope of ALSDA data collected and submitted by PIs include study design metadata, subject metadata, assay metadata (parameters), raw and processed assay data, assay imagery/video, and subject-experienced mission data telemetry (radiation, temperature, humidity, acoustics, vibrations, etc.). In 2021, a community of researchers rallied to form the ALSDA Analysis Working Group (AWG) and provided scientific consensus on dataset sample and assay metadata. The community and excitement around the ALSDA/OSDR system has already led to several data reuse studies, demonstrating value using machine learning (ML), knowledge graphs, and meta-analysis approaches.

space biology↗

Biological Data for Deep Space Mission Support

Increased biomedical risks and challenges associated with deep space missions (cis-Lunar, Mars transit, Mars surface) require new knowledge discovery and development of novel ecosystem and biomedical support capabilities. This paradigm shift supporting distant and long-duration missions requires biological data to be findable, accessible, interoperable, reusable (FAIR), and maximally open-access (i.e., there is a data governance continuum from closed to mediated to embargoed to open). The NASA “Open Science Data Repositories” (OSDR) aims to meet scientific, technical, and operational spaceflight needs, and offers the ability to upload, download, search, share, analyze, and visualize data across physiological, behavioral, ‘omics, and environmental monitoring telemetry datasets. OSDR includes NASA GeneLab, NASA Ames Life Sciences Data Archive (ALSDA), and NASA Biological Institutional Scientific Collection (NBISC). In the past year, ALSDA has undergone a transformation in its data collection, curation, and architecture methods. Standardizing non-genomic (phenotypic) datasets was, and will continue to be, a challenge because of their diverse nature (e.g., molecular, cellular, tissue, whole organism, behavior; micro-computed tomography, intraocular pressure, fluorescence microscopy, western blot, ultrasonography; tabular, images, video). This year ALSDA, alongside GeneLab, introduced the Biological Data Management Environment (BDME) with the purpose to accept submission of data from space relevant experiments including spaceflight, radiation, simulated gravity, gravitropism, isolation and confinement, hostile closed environments and/or distance from Earth. In addition to bringing together omics, phenotypic, physiological, bioimaging, and behavioral data into one repository. By integrating with GeneLab a multi-project submission portal aims to reduce the burden on PIs submitting data and enabling the discovery of both omics and phenotypic data. The purpose of ALSDA is to collect, curate, and make all non-human space-relevant biological data maximally findable, accessible, interoperable, and reusable (FAIR). These scope of ALSDA data collected and submitted by PIs include study design metadata, subject metadata, assay metadata (parameters), raw and processed assay data, assay imagery/video, and subject-experienced mission data telemetry (radiation, temperature, humidity, acoustics, vibrations, etc.). In 2021, a community of researchers rallied to form the ALSDA Analysis Working Group (AWG) and provided scientific consensus on dataset sample and assay metadata. The community and excitement around the ALSDA/OSDR system has already led to several data reuse studies, demonstrating value using machine learning (ML), knowledge graphs, and meta-analysis approaches.

space biology↗

Development of Time Lapse VSP Integration Workflow: A Case Study at Farnsworth CO2-EOR Project

Abstract This study aims to develop a 4D Vertical Seismic Profile (VSP) integration workflow to improve the prediction of subsurface stress changes. The selected study site is a 5-spot pattern within the ongoing CO2-EOR operations at the Farnsworth Field Unit FWU in Ochiltree County, Texas. The specific pattern has undergone extensive geological and geomechanical characterization through the acquisition of 3D seismic data, geophysical well logs, and core. This workflow constrains a numerical hydromechanical model by applying a penalty function formed between "modeled" versus "observed" time-lapse compressional and shear seismic velocity changes. Analyses of geophysical logs and ultra-sonic measurements on core exhibit measurable sensitivities to changes in both fluid saturation and mean effective stress. These data are used to develop a site-specific rock physics model and stress-velocity relationship, which inform the numerical models used to generate the "modeled" portion of the penalty function. The "observed" portion of the penalty function is provided by a novel elastic full-waveform inversion of the available 3D baseline and three monitor surveys to produce high-quality estimates of time-lapse compressional and shear seismic velocity changes. The modeling workflow accounts sequentially for fluid substitution and stress impacts. Hydrodynamic and geomechanical properties of the 3D coupled numerical model are estimated through geostatistical integration of well log and core data with 3D seismic inversion products. Changes in seismic velocities due to fluid substitution are computed using the Biot-Gassmann workflow and site-specific rock physics. Stress impacts on time-lapse seismic velocity changes are modeled from the effective stress output of the hydromechanical model and are initially based on the velocity versus effective stress relationship extracted from core mechanical testing. Based on the principle of superposition of seismic wavefields, seismic velocity changes attributed to fluid substitution and that due to changes in mean effective stress are treated as linearly additive. The modeled results are upscaled using Backus averaging to reconcile scale discrepancies between the modeled and measured datasets to formulate the penalty function. This manuscript presents the forward modeling process and concludes that for the base case, the seismic velocity changes due to mean effective stress dominates over the seismic velocity changes attributed to fluid substitution because of the extensive range of the pressure perturbations. Successful minimization of this penalty function calibrates the coupled hydrodynamic geomechanical numerical model and affirms the suitability of acoustic time-lapse measurements such as 4D-VSP for geomechanical calibration.

02 PETROLEUM↗

TPSAS-NF1676L-11435-DND

Acoustical studies of atmospheric events like convective storms, shear-induced turbulence, acoustic gravity waves, microbursts, hurricanes, and clear air turbulence (CAT) over the past thirty years have established that these events are strong emitters of infrasound. Several mechanisms for the production of infrasound have been proposed, for example by the acceleration of vorticity or by space-time correlations of the turbulent Reynolds stresses (Lighthill theory). Electromagnetic (EM) sensors suffer two severe disadvantages in the detection of clear air turbulence and severe storms. The first is the inability to receive returns in clear air, where reflective targets (precipitation, particulate matter) are absent. The second disadvantage is that EM systems, being active, require scanning to locate an event, as opposed to a passive infrasonic array, which receives infrasonic radiation independently of event location. Further, EM systems, even weather radar ("NEXRAD"), do not have the extensive range (hundreds of miles) characteristic of infrasound. The leading laboratory for studies on atmospheric infrasound over the past thirty years has been the Environmental Technology Laboratory of the National Oceanic and Atmospheric Administration. This laboratory conducted measurements of infrasound from many sources, among which clear air turbulence was but a small part of the overall program. The summary of the results of this program suggests for development of a practical detection system. In other words, despite the progress made in this area, there does not exist today a National network of stations to monitor infrasound from turbulence. Under Innovative Partnership Program, Researchers at NASA Langley Research Center have been working to achieve that goal. As a first step, NASA Langley has designed and developed a portable infrasonic detection system which can be used to make useful infrasound measurements at a location where it was not possible previously. The design and results of the compact system, based upon laboratory and field experiments, will be presented.

Qamar Shams↗

NASA Wearable Technology CLUSTER 2013-2014 Report

Wearable technology has the potential to revolutionize the way humans interact with one another, with information, and with the electronic systems that surround them. This change can already be seen in the dramatic increase in the availability and use of wearable health and activity monitors. These devices continuously monitor the wearer using on-­‐body sensors and wireless communication. They provide feedback that can be used to improve physical health and performance. Smart watches and head mounted displays are also receiving a great deal of commercial attention, providing immediate access to information via graphical displays, as well as additional sensing features. For the purposes of the Wearable Technology CLUSTER, wearable technology is broadly defined as any electronic sensing, human interfaces, computing, or communication that is mounted on the body. Current commercially available wearable devices primarily house electronics in rigid packaging to provide protection from flexing, moisture, and other contaminants. NASA mentors are interested in this approach, but are also interested in direct integration of electronics into clothing to enable more comfortable systems. For human spaceflight, wearable technology holds a great deal of promise for significantly improving safety, efficiency, autonomy, and research capacity for the crew in space and support personnel on the ground. Specific capabilities of interest include: Continuous biomedical monitoring for research and detection of health problems. Environmental monitoring for individual exposure assessments and alarms. Activity monitoring for responsive robotics and environments. Multi-modal caution and warning using tactile, auditory, and visual alarms. Wireless, hands-free, on-demand voice communication. Mobile, on-demand access to space vehicle and robotic displays and controls. Many technical challenges must be overcome to realize these wearable technology applications. For example, to make a wearable device that is both functional and comfortable for long duration wear, developers must strive to reduce electronic mass and volume while also addressing constraints imposed by the body attachment method. Depending on the application, the device must be placed in a location that the user can see and reach, and that provides the appropriate access to air and the wearer's skin. Limited power is available from body-­‐worn batteries and heat must be managed to prevent discomfort. If the clothing is to be washed, there are additional durability and washability hurdles that traditional electronics are not designed to address. Finally, each specific capability has unique technical challenges that will likely require unique solutions. In addition to the technical challenges, development of wearable devices is made more difficult by the diversity of skills required and the historic lack of collaboration across domains. Wearable technology development requires expertise in textiles engineering, apparel design, software and computer engineering, electronic design and manufacturing, human factors engineering, and application-­‐specific fields such as acoustics, medical devices, and sensing. Knowledge from each of these domains must be integrated to create functional and comfortable devices. For this reason, the diversity of knowledge and experience represented in the Wearable Technology is critical to overcoming the fundamental challenges in the field.

Simon, Cory↗