Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “AC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Interleaved Cuk Converter Wave Energy System With Advanced Control and Grid Support Functions for Seamless Integration

This paper presents an innovative wave energy conversion system that integrates an interleaved Cuk converter with advanced nonlinear control for seamless grid integration. The system efficiently extracts power on the DC side using the interleaved Cuk converter, while an inverter manages power transfer to the grid or load on the AC side. A nonlinear control architecture, based on the Lyapunov energy function, ensures stable and optimal operation under varying wave conditions, effectively addressing the challenges of variability and unpredictability inherent in wave energy. The proposed system also incorporates features to enhance power quality and minimize losses, making it a robust solution for renewable energy integration. The system's effectiveness in harnessing wave energy and achieving smooth grid integration is validated through comprehensive computer simulations in MATLAB/Simulink, with case study results demonstrating its capabilities.

HYDRO ENERGY,TIDAL AND WAVE POWER↗

High-Frequency, Multiclass Nonintrusive Load Monitoring for Grid-Interactive Residential Buildings

Smart buildings with net-load metering and control capabilities can provide valuable flexibility to grid operators. This article develops a novel approach for high-frequency, multiclass nonintrusive load monitoring (NILM) that enables effective net-load monitoring capabilities with minimal additional equipment and cost. Relative to existing NILM work, the proposed solution operates at a faster timescale, providing accurate multiclass state predictions for each 60-Hz ac cycle without relying on event-detection techniques. The approach is validated using a test bed with residential appliances and shown to have high accuracy, good generalization properties, and sufficient response time to support building grid-interactive control at fast timescales relevant to the provision of grid frequency support services.

27 ARPA - Advanced Research Projects Agency-Energy↗

Impact Analysis of Data Integrity Attacks on FACTS-based Wide-Area Voltage Control System

Energy management system (EMS) consists of several wide-area control applications that serve as a backbone for security, stability, and reliability of the power system. Wide-area voltage control system (WAVCS), one of the critical wide-area applications, operates in coordination with local Flexible AC Transmission System (FACTS) devices to provide voltage security and optimal management of active and reactive power resources. Since the WAVCS relies on wide-area communication and data sharing devices, possible cybersecurity vulnerabilities have to be addressed to ensure the closed-loop operation of WAVCS. In this paper, we present a methodology for performing an impact analysis of cyber-attacks in WAVCS cybersecurity. In particular, different types of data integrity attacks, such as malicious tripping, fault replay, and signal altering attacks, are considered, and detailed impact analysis is conducted in a testbed environment using the Kundur's four machine two-area system. For performing an impact analysis, the transient voltage stability of the sensitive bus voltage is studied, followed by the quantitative assessment and severity ranking using the voltage profile index. Our experimental evaluation reveals that the data integrity attacks on control signals exhibit a higher attack severity than on the measurement signals. Further, the severity of these attacks varies with nature (static or dynamic), location, and types of attacks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Machine Learning-based Cyber-Physical Anomaly Detection in Wide Area Voltage Control Systems

Wide-area voltage control systems (WAVCS) are widely deployed in power grid to improve the voltage stability in transmission system using Flexible AC Transmission System (FACTS) devices. The WAVCS relies on wide-area measurement and control signals for closed-loop control of FACTS devices to improve the transient voltage stability in power grid in real-time. Since the WAVCS utilizes a cyber-layer communication during its normal operation, they are susceptible to cyber attacks from adversaries which can lead to a voltage collapse if the attacks go undetected and unmitigated. This paper proposes a supervised machine learning (ML)-based anomaly detection algorithm for detecting various stealthy cyber attacks in the context of WAVCS cybersecurity. In particular, a fuzzy logic-based wide-area controller, as proposed by the Bonneville Power Administration (BPA), is implemented on the Kundur’s four machine two-area system that is integrated with a static var compensator (SVC) to improve voltage profile on sensitive buses. Later, different types of data integrity attacks, including pulse and ramp attacks, are considered on the wide-area measurement and control signals to analyze the performance of the proposed anomaly detector. Our experimental evaluation shows a promising performance with a high true-positive rate (more than 99%) and low false-negative rate (less than 1%) while exhibiting a small prediction time.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Current Source Inverter Based Large Constant Power Speed Ratio SPM Machine Drive for Traction Applications

A high-performance surface permanent magnet (SPM) machine drive with an extended constant power speed ratio is proposed using a current source inverter (CSI) for a traction application. The constant-power operation regions of an SPM machine can be extended in an appealing fashion by taking advantage of the output voltage boost capability of the CSI. The CSI is naturally a boost-type converter, in contrast to the voltage source inverter (VSI) which has buck-type characteristics. To investigate the value of the CSI voltage boost feature, a new traction motor with higher rated voltage and lower rated current has been designed and compared to the motor that would be used with a VSI. The lower CSI current makes it possible to reduce the mass of the inverter and output power cable, benefiting power density and cost reduction. The SPM machine is modeled in the synchronous reference frame including the effect of the ac filter capacitors at the CSI output terminals. The capability of extending the speed range of the proposed motor is verified via closed-form analysis and FEA simulation, and its performance characteristics are compared with those of a VSI-based SPM motor of the same type.

42 ENGINEERING↗

Stability Analysis of Parallel Connected Bidirectional WPT System

This paper presents a stability analysis of parallel-connected bi-directional series-series resonant network wireless power transfer (WPT), optimized for Electric Vehicle (EV) charging and vehicle-to-grid (V2G) applications. The study addresses critical stability challenges in systems integrated with diverse distributed energy resources (DERs), including photovoltaics, fuel cells, wind turbines, energy storage systems, and the AC grid. The stability of such integrated DC grid systems is paramount for ensuring reliable operation, particularly under varying power flow conditions and dynamic interactions between parallel WPT systems. The analysis included system impedance characterization, state-space modeling, and open and closed-loop stability evaluations. The results demonstrated that the integration of a robust control architecture effectively mitigates instability risks and supports scalable, efficient operation. This work underscores the converter's adaptability and its potential for large-scale deployment in wireless EV charging infrastructures and integrated DC grid systems.

Asa, Erdem [ORNL] (ORCID:0000000190884812)↗

A Voltage Injection-Based Current Harmonics Suppression Strategy for Six-Phase PMSM With Nonsinusoidal Back EMF

This article presents a voltage injection-based current harmonic minimization method for wide bandgap device-based six-phase permanent magnet synchronous machine (PMSM) drives. The presence of low-order harmonics is common in the back EMF of PMSMs with low slot and high pole numbers. The back EMF harmonics generate low-order harmonic currents that increase torque ripples. Furthermore, zero-sequence current (ZSC) is also observed if all six phases are connected to a common neutral point. ZSC does not affect the torque ripple but reduces the system efficiency. A special technique is required to reduce ZSC for variable speed drives as direct ac component to synchronous reference frame (SRF) dc transformation is not possible for ZSC. In this article, a voltage injection-based current harmonics reduction method is proposed. The injected harmonic voltage coefficients are calculated from the harmonic estimations of back EMF and updated using closed-loop harmonic compensators to improve steady-state performance. For ZSC reduction, third harmonics power controller, and for 6n ± 1 (n = 1, 2,...) order harmonic current reduction, SRF current controllers are presented in this article. Furthermore, the current harmonics minimization method is experimentally verified using a GaN-based three-level active neutral point clamped inverter-driven six-phase PMSM.

42 ENGINEERING↗

Medium Voltage Converter Inductor Insulation Design Considering Grid Requirements

Medium voltage (MV) SiC devices facilitate direct (without 50-/60-Hz transformer) connection of the power electronics converter to the MV grid using simple topology. Compared to the insulation design of MV inductors that have been widely used in the power system, the insulation design of the MV converter filter inductors has new challenges. Particularly, the grid impact on insulation requirements on converter filter inductors is rarely discussed. This article introduces the insulation design of a grid-side filter inductor for a 13.8-kV power conditioning system converter. The grid insulation requirements, including the short-duration power frequency overvoltage and the lightning impulse voltage, are considered in the design. To meet the requirements, the layer-to-layer insulation, winding-to-core/ground insulation, the air gap discharge between the winding and the core, the local electric field, as well as the interturn transient voltage distribution are considered. Furthermore, the designed inductors are validated by the 46 kV (>1 min) dc hi-pot test, 12-kV ac partial discharge test, one-hour single-phase converter full rating test, as well as three-phase converter full rating test.

42 ENGINEERING↗

CPES-QSM: A Quantitative Method Towards the Secure Operation of Cyber-Physical Energy Systems

Power systems are evolving into cyber-physical energy systems (CPES) mainly due to the integration of modern communication and Internet-of-Things (IoT) devices. CPES security evaluation is challenging since the physical and cyber layers are often not considered holistically. Existing literature focuses on only optimizing the operation of either the physical or cyber layer while ignoring the interactions between them. This paper proposes a metric, the Cyber-Physical Energy System Quantitative Security Metric (CPES-QSM), that quantifies the interaction between the cyber and physical layers across three domains: electrical, cyber-risk, and network topology. A method for incorporating the proposed cyber-metric into operational decisions is also proposed by formulating a cyber-constrained AC optimal power flow (C-ACOPF) that considers the status of all the CPES layers. The C-ACOPF considers the vulnerabilities of physical and cyber networks by incorporating factors such as voltage stability, contingencies, graph-theory, and IoT cyber risks, while using a multi-criteria decision-making technique. We note that simulation studies are conducted using standard IEEE test systems to evaluate the effectiveness of the proposed metric and the C-ACOPF formulation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Intelligent Electrochemical Sensors for Precise Identification of Volatile Organic Compounds Enabled by Neural Network Analysis

The volatile organic compounds (VOCs) in a wide spectrum of categories were identified as biomarkers in aquatic environments, playing an important role in marine and freshwater ecology and global atmospheric chemistry. VOCs released from biofuel have also attracted increasing attention. Although the importance has been recognized, the portable detection and analysis methods of VOC in aquatic systems have not yet been well developed and understood. Here, in this work, we innovatively proposed an intelligent electrochemical sensing approach to classify and quantify VOCs in solution. Utilizing the cyclic voltammetry (CV) method with an ionic liquid (IL)-based electrolyte, we analyzed 50 μL samples of various VOC analytes, including acetic acid (AC), acetone, dimethylformamide (DMF), dimethyl sulfoxide (DMSO), ethanol, formaldehyde, formic acid, methanol, methyl formate (MF), toluene, and a formaldehyde-methanol mixture, along with deionized water (DI water). The generated voltammograms were subsequently analyzed using our uniquely designed and optimized 1-D convolutional neural network (1D-CNN). This deep-learning algorithm achieved a 99.09% accuracy in VOC classification validated through fivefold cross-validation and demonstrated an impressive 94.4% test accuracy for methanol detection within a 10 μL error range. For quantification, the system accurately categorized methanol volumes ranging from 0 to 50 μL in 10 μL increments, achieving a 98.18% accuracy. A notable linear correlation (R2 = 95.56%) was found between max current density at the oxidation peak and methanol volume, with the limit of detection (LOD) at 9.3 μL. Such a sensing method exhibits potential for portability, high accuracy, and generalization in the classification and quantification, ultimately reshaping the realm of VOC analysis in solution.

42 ENGINEERING↗

Constraints on OPF Surrogates for Learning Stable Local Volt/Var Controllers

We consider the problem of learning local Volt/Var controllers in distribution grids (DGs). Our approach starts from learning separable surrogates that take both local voltages and reactive powers as arguments and predict the reactive power setpoints that approximate optimal power flow (OPF) solutions. We propose an incremental control algorithm and identify two different sets of slope conditions on the local surrogates such that the network is collectively steered toward desired configurations asymptotically. Our results reveal the trade-offs between each set of conditions, with coupled voltage-power slope constraints allowing an arbitrary shape of surrogate functions but risking limitations on exploiting generation capabilities, and reactive power slope constraints taking full advantage of generation capabilities but constraining the shape of surrogate functions. AC power flow simulations on the IEEE 37-bus feeder illustrate their guaranteed stability properties and respective advantages in two DG scenarios.

asymptotic stability↗

DC Arc Incident Energy in Photovoltaic Systems: Methods for Evaluation

Renewable energy systems continue to be one of the fastest growing segments of the energy industry. This article focuses on the understanding of how photovoltaic (PV) technology behaves under dc arc conditions. Emphasis is placed on the electrical safety aspect of dc arc-flash incident energy (IE) evaluation. Because of the fast proliferation of PV systems and lack of formal equivalent calculation guidelines, such as IEEE 1584 for ac systems, it has been necessary to rely on different equations and models presented by various researchers over the last few years. This article discusses the behavior of PV systems under arc conditions and presents the results of the available methods to estimate the dc arc-flash IE. It provides a comparative analysis of a proposed arc-flash IE calculation method against different laboratory tests, including those performed for this article at the National Renewable Energy Laboratory (NREL). Detailed explanations are provided regarding the effect of the PV module current-voltage (I-V) and power-voltage (P-V) curves under arcing conditions. Examples of the application of the proposed calculation method to the test measurements are included.

arc discharges↗

Grid-Forming Inverters: Project Demonstrations and Pilots

Power system operators around the world are pushing the limits of integrating inverter-based resources (IBRs) to very high levels, approaching 100% instantaneous penetration under certain operating conditions. This often applies to smaller power systems with very little or no ac interconnections to other neighboring regions or sometimes to fringes of large balancing areas, such as Denmark or Portugal, within the mainland European power system. These jurisdictions have identified the potential of grid-forming (GFM) technology as a key enabler to support the energy transition with very few or no synchronous generators online. Until recently, practical applications of GFM inverters were limited to microgrids and isolated grids and in smaller grid applications on the order of a few tens of megawatts (MW).

Australia↗

Real-time Optimal Dispatch of Behind-the-Meter DERs for Secondary Frequency Regulation

Active distribution networks (ADNs) can provide grid services such as peak load shaving, loss reduction, VoltNar control, congestion management, and frequency regulation. The fast response of inverter-based distributed energy resources (DERs) and battery storage systems enables them to provide ramping support and frequency control. This paper proposes a real-time optimization approach for behind-the-meter DERs to participate in the secondary frequency regulation. The proposed approach determines optimal set-points of output power of DERs to respond to requests from system operators (SOs) in realtime to maintain the frequency of the system at the nominal value. To satisfy the real-time requirement for the secondary frequency control, the nonlinear AC power flow model is linearized considering power losses in the system to achieve both high computational speed and acceptable accuracy. The optimization problem is rerun in a closed loop manner until the mismatch between the requested power by the system operators and actual delivered power at the substation reaches an acceptable tolerance. Furthermore, the proposed approach is validated using modified versions of the IEEE 33-bus and IEEE 69-bus distribution systems. Although the contribution of a single distribution system in the frequency regulation may not be significant, stacked and coordinated contributions from several distribution systems can provide frequency regulation and other grid services at scale.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hardware Demonstration of Weak Grid Oscillations in Grid-Following Converters

The increasing penetration of inverter-based resources (IBRs) introduces some unexpected dynamic issues, including low-frequency oscillations. In this paper, a laboratory-scale grid-following voltage-source converter (VSC) system is implemented to demonstrate weak grid oscillations. Grid-following control is applied in VSC to provide active power, reactive power or ac voltage control. The test bed is also replicated in electromagnetic transient (EMT) simulation environment (MAT-LAB/SimPowerSystems) for benchmark purpose. Case studies are carried out to demonstrate low-frequency oscillations under real power/ac voltage or real power/reactive power control. The excellent agreement between the simulation and experimental results ensures that the two test beds are exchangeable and can be used for testing oscillation mitigation strategies in future research.

Bao, Li↗