Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “timing detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Design of Low Power CMOS Read-Out with TDI Function for Infrared Linear Photodiode Array Detectors

A new low voltage CMOS infrared readout circuit using the buffer-direct injection method is presented. It uses a single supply voltage of 1.8 volts and a bias current of 1uA. The time-delay integration technique is used to increase the signal to noise ratio. A current memory circuit with faulty diode detection is used to remove dark current for background compensation and to disable a photodiode in a cell if detected as faulty. Simulations are shown that verify the circuit that is currently in fabrication in 0.5ym CMOS technology.

Vizcaino, Paul↗

Advanced ACTPol Cryogenic Detector Arrays and Readout

Advanced ACTPol is a polarization-sensitive upgrade for the 6 m aperture Atacama Cosmology Telescope, adding new frequencies and increasing sensitivity over the previous ACTPol receiver. In 2016, Advanced ACTPol will begin to map approximately half the sky in five frequency bands (28-230 GHz). Its maps of primary and secondary cosmic microwave background anisotropies-imaged in intensity and polarization at few arcminute-scale resolution-will enable precision cosmological constraints and also awide array of cross-correlation science that probes the expansion history of the universe and the growth of structure via gravitational collapse. To accomplish these scientific goals, the AdvancedACTPol receiver will be a significant upgrade to the ACTPol receiver, including four new multichroic arrays of cryogenic, feedhorn-coupled AlMn transition edge sensor polarimeters (fabricated on 150 mm diameter wafers); a system of continuously rotating meta-material silicon half-wave plates; and a new multiplexing readout architecture which uses superconducting quantum interference devices and time division to achieve a 64-row multiplexing factor. Here we present the status and scientific goals of the Advanced ACTPol instrument, emphasizing the design and implementation of the AdvancedACTPol cryogenic detector arrays.

secondary cosmic microwave background anisotropies↗

New Generation Lidar Technology and Applications

Lidar has been a tool for atmospheric research for several decades. Until recently routine operational use of lidar was not known. Problems have involved a lack of appropriate technology rather than a lack of applications. Within the last few years, lidar based on a new generation of solid state lasers and detectors have changed the situation. Operational applications for cloud and aerosol research applications are now well established. In these research applications, the direct height profiling capability of lidar is typically an adjunct to other types of sensing, both passive and active. Compact eye safe lidar with the sensitivity for ground based monitoring of all significant cloud and aerosol structure and the reliability to operate full time for several years is now in routine use. The approach is known as micro pulse lidar (MPL). For MPL the laser pulse repetition rate is in the kilohertz range and the pulse energies are in the micro-Joule range. The low pulse energy permits the systems to be eye safe and reliable with solid state lasers. A number of MPL systems have been deployed since 1992 at atmospheric research sites at a variety of global locations. Accurate monitoring of cloud and aerosol vertical distribution is a critical measurement for atmospheric radiation. An airborne application of lidar cloud and aerosol profiling is retrievals of parameters from combined lidar and passive sensing involving visible, infrared and microwave frequencies. A lidar based on a large pulse, solid state diode pumped ND:YAG laser has been deployed on the NASA ER-2 high altitude research aircraft along with multi-spectral visible/IR and microwave imaging radiometers since 1993. The system has shown high reliability in an extensive series of experimental projects for cloud remote sensing. The retrieval of cirrus radiation parameters is an effective application for combined lidar and passive sensing. An approved NASA mission will soon begin long term lidar observation of atmospheric structure from space. The Geoscience Laser Altimeter System (GLAS) of the Earth Observing System is scheduled for deployment in the 2001 time frame. GLAS is both a cloud and aerosol lidar and a surface altimeter, principally for monitoring of polar ice sheets. The GLAS instrument is based on all solid state lasers operating at 40 Hz and high efficiency, solid state detectors. The design lifetime is three to five years. Data from the GLAS mission is expected to revolutionize some aspects of our understanding of the global distribution of cloud and aerosols for global climate prediction.

Spinhirne, James D.↗

Solar flare gamma-ray and hard x ray imaging with the GRID-on-a-balloon

A primary scientific objective for solar flare research during the rapidly approaching maximum in solar activity is the imaging of gamma-ray and hard x ray sources of solar flare emissions. These goals will be pursued by the Gamma Ray Imaging Device (GRID) instrument, one of three instruments recently selected for NASA's Max '91 Solar Balloon Program. The GRID instrument is based on the technique of Fourier transform imaging and utilizes scanning modulation grid collimator optics to provide full-Sun imaging with 1.9-arcsecond resolution over the energy range from 20 to 700 keV at time resolutions from 0.1 to 2 s. The GRID telescope will employ 32 subcollimators, each composed of a matched pair of high-Z collimator grids separated by 5.2 meters and a phoswich scintillation spectrometer detector having no spatial resolution. The subcollimators and integrally-mounted fine aspect system are contained within a telescope canister which will be pointed to 0.1 degree accuracy and cyclically scanned to produce source modulation. The 32 subcollimators provide a uniform distribution of grid slit orientations and a logarithmic distribution of slit spacings corresponding to angular dimensions of 1.9 arcseconds to several arcminutes. The instrument is several orders of magnitude more sensitive than the HXIS instrument on the Solar Maximum Mission (SMM) and nearly 10 times more sensitive than any similar instrument scheduled to fly during the next solar maximum. The payload, designed for long-duration high-altitude balloon capability, is scheduled for its first science flight (8 to 14 days duration) from the Antarctic in January of 1992.

Orwig, Larry E.↗

Helios-2 Vela-Ariel-5 gamma-ray burst source position

The gamma-ray burst of 28 January 1976, one of 18 events thus far detected in interplanetary space with Helios-2, was also observed with the Vela-5A, -6A and the Ariel-5 satellites. A small source field is obtained from the intersection of the region derived from the observed time delays between Helios-2 and Vela-5A and -6A with the source region independently found with the Ariel-5 X-ray detector. This area contains neither any steady X-ray source as scanned by HEAO-A nor any previously catalogued X-ray, radio or infrared sources, X-ray transients, quasars, seyferts, globular clusters, flare stars, pulsars, white dwarfs or high energy gamma-ray sources. The region is however, within the source field of a gamma-ray transient observed in 1974, which exhibited nuclear gamma-ray line structure.

Cline, T. L.↗

The MSFC vector magnetograph

The NASA/Marshall Space Flight Center's solar vector magnetograph system allows measurements of all components of the Sun's photospheric magnetic field over a 5 x 5 or 2.5 x 2.5 arc min square field of view with an optimum time resolution of approximately 100 sec and an optimum signal-to-noise of approximately 1000. The basic system components are described, including the optics, detector, digital system, and associated electronics. Automatic sequencing and control functions are outlined as well as manual selections of system parameters which afford unique system flexibility. Results of system calibration and performance are presented, including linearity, dynamic range, uniformity, spatial and spectral resolutions, signal-to-noise, electro-optical retardation and polarization calibration.

Hagyard, M. J.↗

Stereoscopic Optical Signal Processor

Optical signal processor produces two-dimensional cross correlation of images from steroscopic video camera in real time. Cross correlation used to identify object, determines distance, or measures movement. Left and right cameras modulate beams from light source for correlation in video detector. Switch in position 1 produces information about range of object viewed by cameras. Position 2 gives information about movement. Position 3 helps to identify object.

Graig, Glenn D.↗

Signal-to-noise ratios in IUE SWP-LO spectra of chromospheric emission-line sources

The short-wavelength-prime (SWP) detector of the International Ultraviolet Explorer should operate near the photon-counting limit, but the noise levels in flat-field images are several times higher. The exaggerated noise can be traced to the incomplete removal of the pixel-to-pixel granularity of the television frames by the prevailing spectral image processing system. An empirical noise model for the current-epoch photometric linearization strategy and one for a hypothetical processing system that achieves complete flat fielding of the raw images are derived. A formula is then proposed to predict the signal-to-noise ratio in the measured flux of an emission line (possibly superimposed on a smooth continuum) in an IUE low-dispersion (5 A resolution) far-ultraviolet (1150 A-1950 A) spectrum as recorded with the SWP camera. For illustration, the formula is specialized to the important C IV 1549 A feature of F-K stars. The S/N relation permits one to determine sensitivity limits, upper limits in faint exposures, and optimum exposure times.

Ayres, Thomas R.↗

Inelastic and reactive scattering of hyperthermal atomic oxygen from amorphous carbon

The reaction of hyperthermal oxygen atoms with an amorphous carbon-13 surface was studied using a modified universal crossed molecular beams apparatus. Time-of-flight distributions of inelastically scattered O-atoms and reactively scattered CO-13 and CO2-13 were measured with a rotatable mass spectrometer detector. Two inelastic scattering channels were observed, corresponding to a direct inelastic process in which the scattered O-atoms retain 20 to 30 percent of their initial kinetic energy and to a trapping desorption process whereby O-atoms emerge from the surface at thermal velocities. Reactive scattering data imply the formation of two kinds of CO products, slow products whose translational energies are determined by the surface temperature and hyperthermal (Approx. 3 eV) products with translational energies comprising roughly 30 percent of the total available energy (E sub avl), where E sub avl is the sum of the collision energy and the reaction exothermicity. Angular data show that the hyperthermal CO is scattered preferentially in the specular direction. CO2 product was also observed, but at much lower intensities than CO and with only thermal velocities.

Minton, Timothy K.↗

BATSE flare observations in Solar Cycle 22

The Hard X-Ray Burst Spectrometer (HXRBS) group at GSFC has developed and is maintaining a quick-look analysis system for solar flare hard x-ray data from the Burst and Transient Source Experiment (BATSE) on the recently launched Compton Gamma-Ray Observatory (GRO). The instrument consists, in part, of 8 large planar detectors, each 2025 sq cm, placed on the corners of the GRO spacecraft with the orientation of the faces being those of a regular octahedron. Although optimized for the detection of gamma-ray bursts, these detectors are far more sensitive than any previous spacecraft-borne hard x-ray flare instrumentation both for the detection of small microflares and the resolution of fine temporal structures. The data in this BATSE solar data base are from the discriminator large area (DISCLA) rates. From each of eight detectors there are hard x-ray data in four energy channels, 25-50, 50-100, 100-300, and greater than 300 keV with a time resolution of 1.024 seconds. These data are suitable for temporal correlation with data at other wavelengths, and they provide a first look into the BATSE and other GRO instrument flare data sets. The BATSE and other GRO principle investigator groups should be contacted for the availability of data sets at higher time or spectral resolution or at higher energies.

Schwartz, R. A.↗

First Year PIDDP Report on gamma-ray and x-ray spectroscopy: X-ray remote sensing and in situ spectroscopy for planetary exploration missions and gamma-ray remote sensing and in situ spectroscopy for planetary exploration missions

Detectors that will be used for planetary missions must have their responses calibrated in a reproducible manner. In addition, it is important to characterize a detector system at uneven portions of its life cycle, for example after exposure to different amounts of radiation. A calibration and response characterization facility has been constructed at Schlumberger-Doll Research for all types of gamma- and x-ray detectors that may be used for planetary measurement. This facility is currently being tested. Initial use is expected for the MARS 94 detectors. The facility will then also be available for calibrating other detectors as well as arrays of detectors such as the NEAR detector with its central Nal(TI) crystal surrounded with a large BGO crystal. Cadmium telluride detectors are investigated for applications in space explorations. These detectors show an energy resolution of 5 keV for the 122 keV 57Co line. Earlier reported polarization effects are not observed. The detectors can be used at temperatures up to 100 C, although with reduced energy resolution. The thickness of standard detectors is limited to 2 mm. These detectors become fully efficient at bias voltages above 200 V. Initial results for a 1 cm thick detector show that the quality of the material is inferior to the thinner standard detectors and hole trapping affects the pulse height. A detailed characterization of the detector is in progress. Prototypes of photomultipliers based on a Channel Electron Multiplier (CEM) are being built to study their performance. Such photomultipliers promise better timing characteristics and a higher dynamic range while being more compact and of lower in weight.

Mahdavi, M.↗

Measurement of tropospheric OH and HO2 by laser-induced fluorescence at low pressure

The hydroxyl radical (OH) is the primary oxidant in the atmosphere, responsible for many photochemical reactions that affect both regional air quality and global climate change. Because of its high reactivity, abundances of OH in the troposphere are less than 1 part per trillion by volume (pptv) and thus difficult to measure accurately. This paper describes an instrument for the sensitive detection of OH in the troposphere using low-pressure laser-induced fluorescence. Ambient air is expanded into a low pressure detection chamber, and OH is both excited and detected using the A(sup 2) Epsilon(+)(v prime = 0) yields X(sup 2)Pi(v double prime = 0) transition near 308 nm. An injector upstream of the detection axis allows for the addition of reagent NO to convert ambient HO2 to OH using the fast reaction HO2 + NO yields OH + NO2. Using recent advances in laser and detector technologies, this prototype instrument is able to detect less than 1 x 10(exp 5) molecules/cu cm (0.004 pptv) of OH with an integration time of 30 s with negligible interferences.

Stevens, P. S.↗

Solar Coronal Structure Study

The subject of this investigation is to study the physics of the solar corona through the analysis of the EUV and UV data produced by two flights (12 May 1992 and 25 April 1994) of the Lockheed Solar Plasma Diagnostics Experiment (SPDE) sounding rocket payload, in combination with Yohkoh and ground-based data. Each rocket flight produced both spectral and imaging data. These joint datasets are useful for understanding the physical state of various features in the solar atmosphere at different heights ranging from the photosphere to the corona at the time of the, rocket flights, which took place during the declining phase of a solar cycle, 2-4 years before the minimum. The investigation is narrowly focused on comparing the physics of small- and medium-scale strong-field structures with that of large-scale, weak fields. As we close th is investigation, we have to recall that our present position in the understanding of basic solar physics problems (such as coronal heating) is much different from that in 1995 (when we proposed this investigation), due largely to the great success of SOHO and TRACE. In other words, several topics and techniques we proposed can now be better realized with data from these missions. For this reason, at some point of our work, we started concentrating on the 1992 data, which are more unique and have more supporting data. As a result, we discontinued the investigation on small-scale structures, i.e., bright points, since high-resolution TRACE images have addressed more important physics than SPDE EUV images could do. In the final year, we still spent long time calibrating the 1992 data. The work was complicated because of the old-fashioned film, which had problems not encountered with more modern CCD detectors. After our considerable effort on calibration, we were able to focus on several scientific topics, relying heavily on the SPDE UV images. They include the relation between filaments and filament channels, the identification of hot loops, and the physical conditions of such loops especially at their foot-points. A total of four papers were completed from this contract which are listed in the last section.

Nitta, Nariaki↗

Evaluation of Rock Powdering Methods to Obtain Fine-grained Samples for CHEMIN, a Combined XRD/XRF Instrument

A miniature XRD/XRF (X-ray diffraction / X-ray fluorescence) instrument, CHEMIN, is currently being developed for definitive mineralogic analysis of soils and rocks on Mars. One of the technical issues that must be addressed to enable remote XRD analysis is how best to obtain a representative sample powder for analysis. For powder XRD analyses, it is beneficial to have a fine-grained sample to reduce preferred orientation effects and to provide a statistically significant number of crystallites to the X-ray beam. Although a two-dimensional detector as used in the CHEMIN instrument will produce good results even with poorly prepared powder, the quality of the data will improve and the time required for data collection will be reduced if the sample is fine-grained and randomly oriented. A variety of methods have been proposed for XRD sample preparation. Chipera et al. presented grain size distributions and XRD results from powders generated with an Ultrasonic/Sonic Driller/Corer (USDC) currently being developed at JPL. The USDC was shown to be an effective instrument for sampling rock to produce powder suitable for XRD. In this paper, we compare powder prepared using the USDC with powder obtained with a miniaturized rock crusher developed at JPL and with powder obtained with a rotary tungsten carbide bit to powders obtained from a laboratory bench-scale Retsch mill (provides benchmark mineralogical data). These comparisons will allow assessment of the suitability of these methods for analysis by an XRD/XRF instrument such as CHEMIN.

Chipera, S. J.↗

The Diogene 4 pi detector at Saturne

Diogene, an electronic 4 pi detector, has been built and installed at the Saturne synchrotron in Saclay. The forward angular range (0 degree-6 degrees) is covered by 48 time-of-flight scintillator telescopes that provide charge identification. The trajectories of fragments emitted at larger angles are recorded in a cylindrical 0.4-m3 Pictorial Drift Chamber (PDC) surrounding the target. The PDC is inside a 1-T magnetic field; the axis of the PDC cylinder and the magnetic field are parallel to the beam. Good identification has been obtained for both positive and negative pi mesons and for hydrogen and helium isotopes. Multiplicities in relativistic nucleus-nucleus reactions up to 40 have been detected, limited mainly by the present electronics.

Non-NASA Center↗

Curvature-Based Wavefront Sensor for Use on Extended, Arbitrary, Low-Contract Scenes Final Technical Report August 2004

A small amount of work has been done on this project; the strategy to be adopted has been better defined, though no experimental work has been started. 1) Wavefront error signals: The best choice appears use a lenslet array at a pupil image to produce defocused image pairs for each subaperture. Then use the method proposed by Molodij et al. to produce subaperture curvature signals. Basically, this method samples a moderate number of locations in the image where the value of the image Laplacian is high, then taking the curvature signal from the difference of the Laplacians of the extrafocal images at those locations. The tip-tilt error is obtained from the temporal dependence of the first spatial derivatives of an in-focus image, at selected locations where these derivatives are significant. The wavefront tilt can be obtained from the full-aperture image. 2) Extrafocal image generation: The important aspect here is to generate symmetrically defocused images, with dynamically adjustable defocus. The adjustment is needed because larger defocus is required before the feedback loop is closed, and at times when the seeing is worse. It may be that the usual membrane mirror is the best choice, though other options should be explored. 3) Detector: Since the proposed sensor is to work on solar granulation, rather than a point source, an array detector for each subaperture is required. A fast CMOS camera such as that developed by the National Solar Observatory would be a satisfactory choice. 4) Processing: Processing requirements have not been defined in detail, though significantly fewer operations per cycle are required than for a correlation tracker.

LaBonte, Barry J.↗

Radiometric Performance Model for AVIRIS

This slide presentation reviews the radiometric performance model for Airborne Visible/Infrared Imaging Spectrometer (AVIRIS). This model allows for an estimation of the signal throughput and noise properties of AVIRIS for the components. This understanding can point to areas for improvements of the components.. The signal to noise ratio properties may be estimated. An accurate radiometric performance model is essential for the use of existing instruments and the design of new instruments. Included in the presentation is a design view and a picture of the AVIRIS instrument. There is discussion of the signal, the signal area solid angle product, aspects of area solid angle time, the idealized radiometer photon calculation and noise both instrument read and photon counting noise. Graphs of signal throughput efficiency, input radiance, photons at the detector, signal e-, noise e- and the signal to noise ratio are presented.

imaging spectroscopy↗

Regolith and Environment Science and Oxygen and Lunar Volatile Extraction (RESOLVE): Lunar Advanced Volatile Analysis (LAVA) Capillary Fluid Dynamic Restriction Effects on Gas Chromatography

The Resource Prospector (RP) mission with the Regolith and Environment Science and Oxygen Lunar Volatile Extraction (RESOLVE) payload aims to show the presence of water in lunar regolith, and establish a proving ground for NASAs mission to Mars. One of the analysis is performed by the Lunar Advanced Volatiles Analysis (LAVA) subsystem, which consists of a fluid network that facilitates the transport of volatile samples to a gas chromatograph and mass spectrometer (GC-MS) instrument. The understanding of fluid dynamics directed from the GC to the MS is important due to the influence of flow rates and pressures that affect the accuracy of and prevent the damage to the overall GC-MS instrument. The micro-scale capillary fluid network within the GC alone has various lengths and inner-diameters; therefore, determination of pressure differentials and flow rates are difficult to model computationally, with additional complexity from the vacuum conditions in space and lack of a lunar atmosphere. A series of tests were performed on an experimental set-up of the system where the inner diameters of the GC transfer line connecting to the MS were varied. The effect on chromatography readings were also studied by applying these lines onto a GC instrument. It was found that a smaller inner diameter transfer line resulted in a lower flow rate, as well as a lower pressure differential across the thermal conductivity detector (TCD) unit of the GC and a negligible pressure drop across the mock-up capillary column. The chromatography was affected with longer retention times and broader peak integrations. It was concluded that a 0.050 mm inner diameter line still proved most suitable for the systems flow rate preferences. In addition, it was evident that this small transfer line portrayed some expense to GC signal characteristics and the wait time for steady-state operation.

RESOLVE↗