Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “target detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

The Kepler End-to-End Model: Creating High-Fidelity Simulations to Test Kepler Ground Processing

The Kepler mission is designed to detect the transit of Earth-like planets around Sun-like stars by observing 100,000 stellar targets. Developing and testing the Kepler ground-segment processing system, in particular the data analysis pipeline, requires high-fidelity simulated data. This simulated data is provided by the Kepler End-to-End Model (ETEM). ETEM simulates the astrophysics of planetary transits and other phenomena, properties of the Kepler spacecraft and the format of the downlinked data. Major challenges addressed by ETEM include the rapid production of large amounts of simulated data, extensibility and maintainability.

Bryson, Stephen T.↗

Compositional Characteristics and Trends Within the Vera Rubin Ridge, Gale Crater, Mars as Determined by APXS: Sedimentary, Diagenetic and Alteration History

The Mars Science Laboratory (MSL) Curiosity rover has spent the last two years investigating a prominent resistant ridge, informally named the Vera Rubin Ridge (VRR), at the base of Mount Sharp (Aeolis Mons). The ridge has been a high priority science target for the MSL mission since landing in Gale crater more than 6 years ago because of the detection of a strong hematite spectral signature, and its distinct topography. Examining the chemistry of the ridge can aid in determining the relationship to other rocks analyzed during the rover traverse, specifically the Murray formation (fm) encountered below the ridge. We can also determine compositional trends with elevation and/or laterally within the ridge, and whether spectral properties observed on the ridge, both from orbit and in situ, correspond with changes in chemistry. The composition of the ridge, combined with mineralogy of drilled samples, can help to elucidate bigger picture questions regarding depositional environment, possible changing lake water chemistry and diagenetic/alteration history.

Thompson, L. M.↗

Development of Gas Analysis Capabilities

Project Description: The project objective was to develop gas analysis methodology and processes to identify and quantify contaminants specific to KSC, primarily volatile organic compounds (VOCs), utilizing the recently purchased gas chromatograph-mass spectrometer (GCMS) coupled with a sample pre-concentrator. This work established a standing, quick-turnaround quantitative GCMS methodology for KSC-specific VOCs associated with launching and landing spacecraft at trace-levels far below previous detection limits. Closeout Summary: This project established a standing methodology for rapid turnaround identification and quantification of 119 targeted VOCs considered most likely to be encountered at KSC. Of these, 111 of the calibration files are based on manufacturer-certified gas standard mixes. The other eight were generated using standards generated in-house from neat, certified reference materials using procedures for standard generation that were developed under this project. Additionally, the spectral signatures of two hydrofluorocarbon precision cleaning solvents, that are widely used in flight hardware processing, have been added to the mass spectral library for rapid qualitative identification.

Cristina Oropeza↗

Angular Dependence of Drell-Yan in the SeaQuest Experiment using Deep Neural Network-Based Reconstruction

The SeaQuest and SpinQuest experiments at Fermilab were designed to probe the internal dynamics of protons and neutrons via the angular dependence of muons created by colliding 120 GeV protons into stationary targets. To do this, it is necessary to translate the detector data into coherent information about the particles detected in the experiment. This dissertation describes the development and implementation of QTracker, a neural network-based algorithm designed to reconstruct muons. The application of QTracker to experimental data yields improved reconstruction of muon tracks, allowing for a more precise investigation of the transverse momentum distributions and angular modulations in the Drell-Yan process. This work highlights the potential of neural network-based methods to advance particle tracking and enhance our understanding of nucleon structure.

Conover, Arthur↗

A New Antibody for Category 1 Biomarker Detection

At least two questions arise in developing a life-detection strategy: What do we look for and what will positive detection tell us? Unfortunately, many 'biomarkers' are not conclusive markers of biology. For example, sugars, amino acids, polycyclic aromatic hydrocarbons (PAH) and certain bacteria-like morphologies can all be produced non-biologically. Inferences of life following the detection of several inconclusive biomarkers in one sample will always be questioned. Although DNA, RNA and proteins are excellent markers of biology, and preserved on Earth for several millions of years, their survival over longer periods of time is low. Ideally, we should target biomarkers which are both stable over time and formed exclusively from biological processes, i.e. a 'category 1' biomarker under the new classification system of Mckay. We have used antibodies to detect category 1 and other biomarkers in rock samples. Extraction takes a few minutes and analysis a few hours. We have presented use of new antibodies to detect hopanes and have shown proof of operation during martian gravity.

Maule, J.↗

Validation of neutron-induced reactions on natural carbon using an active target at neutron energies up to 22 MeV at LANSCE

A single crystal chemical vapor deposited (sCVD) diamond detector is used as an active target to measure neutron-induced reactions on natural carbon using the neutrons produced by spallation, with a broad energy spectrum at LANSCE. Additionally, the neutron-induced reactions are detected in the diamond as low as E n = 400 keV and up to approximately 100 MeV. Relative cross sections for C 12 ( n , α 0 ) , C 12 ( n , p 0 ) , C 12 ( n , d 0 + p 1 ) , and C 13 ( n , α 0 ) are reported up to E n = 22 MeV and comparisons on detected pulse-height spectra and detector response of scattering reactions are made with GEANT4 simulations using the ENDF/B-VIII.0 evaluated nuclear data library up to 20 MeV. The results are compared with past experimental data, including other works that incorporate diamond detectors as an active carbon target. In addition, R-matrix calculations for the C 13 + n system are presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multiple-ionization of xenon atoms by positron impact

Previously the cross sections were measured for positronium formation and single ionization by positron impact for He and H2. With the same apparatus, slightly modified, the single and multiple ionization of xenon is now investigated. The principle of the method is the detection of ion and positron in time correlation which allows the discrimination of positronium formation (whereby the positron vanishes) and the destinction of single, double and triple impact ionization (which lead to different ion flight times from the gas target to the ion detector). By using secondary electrons from the positron moderator, similar measurements were performed on electron impact ionization. By comparing with literature values for electron multiple ionization cross sections, the detection-probability ratios were determined for the differently charged ions.

Kruse, Georg↗

Scaling Trivalent Actinide and Lanthanide Recovery by Diglycolamide Resin from Savannah River Site’s Mark-18A Targets

The Savannah River National Laboratory is implementing a separation flowsheet to recover rare isotopes and transplutonium elements from irradiated 242 Pu targets known as Mark-18A targets. The Mark-18A targets contain the United States’ supply of nonseparated 244 Pu, which has a wide range of applications from nuclear forensics to production of superheavy elements such as flerovium. The targets also contain hundreds of grams of heavy curium ( 246–248 Cm), which is used as a target material for 252 Cf production. This work investigates the use of diglycolomide resin (DGA Resin) to recover valuable trivalent actinides from the Mark-18A targets. Batch contact experiments were performed on a representative simulant to determine mass loadings. Furthermore, the resin showed an overall capacity of 11 mg/mL for a mixed metal matrix (Zr and La–Gd). Column experiments showed chromatographic separation with transition-metal breakthroughs occurring first followed by the lanthanide series La–Gd. The experiments showed that lanthanide breakthrough occurred after 11 mg/mL mass loading was reached on the column with the mixed metal matrix. A radiological column experiment with an in-line UV/vis cell was able to detect Nd breakthrough just prior to 241 Am breakthrough. Implementing an in-line UV/vis cell into full-scale Mark-18A target processing will be used to limit breakthrough of trivalent actinides recovered from the targets.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Kimberlina 1.2 Velocity Models and Seismic Data

Kimberlina 1.2 Velocity model and synthetic seismic data, produced in collaboration of teams at the National Energy Technology Laboratory, Los Alamos National Laboratory, and Lawrence Livermore National Laboratory through the National Risk Assessment Partnership. Data is associated with the following publication: Zheng Zhou, Youzuo Lin, Zhongping Zhang, Yue Wu, Zan Wang, Robert Dilmore, and George Guthrie, "A Data-Driven CO2 Leakage Detection Using Seismic Data and Spatial-Temporal Densely Connected Convolutional Neural Networks," International Journal of Greenhouse Gas Control, Vol 90, 2019. The Kimberlina 1.2 Velocity models were produced by Zan Wang, Robert Dilmore, William Harbert, and Lianjie Huang at NETL. The following citations are directly related to the creation of the velocity models: Wang, Z. Harbert, W., Dilmore, R., Huang, L. Modeling of time-lapse seismic monitoring using CO2 leakage simulations for a model CO2 storage site with realistic geology: Application in assessment of early leak-detection capabilities. International Journal of Greenhouse Gas Control. V. 76, September 2018, Pages 39-52. https://doi.org/10.1016/j.ijggc.2018.06.011 Wang, Z., Dilmore, R., Harbert, W. Inferring CO2 saturation from synthetic surface seismic and downhole monitoring data using machine learning for leakage detection at CO2 sequestration sites. International Journal of Greenhouse Gas Control, V. 100, September 2020. https://doi.org/10.1016/j.ijggc.2020.103115 The velocity models were built based on the Kimberlina 1.2 aquifer impact data which is associated with the following publications: Buscheck, T.A., Mansoor, K., Yang, X., Wainwright, H., and Carroll, S. (2019). Downhole pressure and chemical monitoring for CO2 and brine leak detection in aquifers above a CO2 storage reservoir. International Journal of Greenhouse Gas Control. 91. 102812. 10.1016/j.ijggc.2019.102812. Xianjin Yang, Thomas A. Buscheck, Kayyum Mansoor, Zan Wang, Kai Gao, Lianjie Huang, Delphine Appriou, Susan A. Carroll, Assessment of geophysical monitoring methods for detection of brine and CO2 leakage in drinking water aquifers, International Journal of Greenhouse Gas Control, Volume 90, 2019, 102803, ISSN 1750-5836, https://doi.org/10.1016/j.ijggc.2019.102803 The synthetic seismic data was produced by Youzuo Lin and team at LANL, and are associated with the following citations: Jordan, P. D., and J. L. Wagoner. Characterizing Construction of Existing Wells to a CO2 Storage Target: The Kimberlina Site, California. Zheng Zhou, Youzuo Lin, Zhongping Zhang, Yue Wu, Zan Wang, Robert Dilmore, and George Guthrie, "A Data-Driven CO2 Leakage Detection Using Seismic Data and Spatial-Temporal Densely Connected Convolutional Neural Networks," International Journal of Greenhouse Gas Control, Vol 90, 2019.

CO2 Leakage↗

RST CGI: Final Verification and Calibration of Prism and Polarizer Flight Units

As part of its technology demonstration, the Nancy Grace Roman Space Telescope Coronagraph Instrument (CGI) will demonstrate point source spectroscopy and polarization measurements of disks. The spectroscopy mode is a zero-deviation Amici prism and slit which is deployed to the planet position after an imaging detection. The Wollaston prism polarization optics allow for imaging two orthogonal polarization states simultaneously. The CGI spectral characterization modes, designed and built at Goddard Space Flight Center (GSFC), have a spectral resolution of R50 in two 15% bandpass centered at 660nm and 730nm. There are duplicate Wollaston prism channels, clocked 45 degrees with respect to one another to completely characterize the instrument polarization effects and recover the Stokes parameters of the targeted disk. The Wollaston design and optical elements are a contribution by the Japanese Aerospace Exploration Agency, with final alignment and testing being done at GSFC. The spectroscopy mode is optimized to target Methane absorption features around 730nm, keeping the spectral resolution as low as possible to improve the signal-to-noise ratio and hence reduce detection time. We highlight the requirements for these modes, the ground-to-orbit calibration process, and the operations required to use a deployable slit on a CGI point source in the presence of pointing error. We also provide further detail on the optomechanical design, testing results from the final as-built flight units, verification process, and performance of the as-built flight assemblies.

high contrast imaging↗

Hyperspectral Fluorescence and Reflectance Imaging Instrument

The system is a single hyperspectral imaging instrument that has the unique capability to acquire both fluorescence and reflectance high-spatial-resolution data that is inherently spatially and spectrally registered. Potential uses of this instrument include plant stress monitoring, counterfeit document detection, biomedical imaging, forensic imaging, and general materials identification. Until now, reflectance and fluorescence spectral imaging have been performed by separate instruments. Neither a reflectance spectral image nor a fluorescence spectral image alone yields as much information about a target surface as does a combination of the two modalities. Before this system was developed, to benefit from this combination, analysts needed to perform time-consuming post-processing efforts to co-register the reflective and fluorescence information. With this instrument, the inherent spatial and spectral registration of the reflectance and fluorescence images minimizes the need for this post-processing step. The main challenge for this technology is to detect the fluorescence signal in the presence of a much stronger reflectance signal. To meet this challenge, the instrument modulates artificial light sources from ultraviolet through the visible to the near-infrared part of the spectrum; in this way, both the reflective and fluorescence signals can be measured through differencing processes to optimize fluorescence and reflectance spectra as needed. The main functional components of the instrument are a hyperspectral imager, an illumination system, and an image-plane scanner. The hyperspectral imager is a one-dimensional (line) imaging spectrometer that includes a spectrally dispersive element and a two-dimensional focal plane detector array. The spectral range of the current imaging spectrometer is between 400 to 1,000 nm, and the wavelength resolution is approximately 3 nm. The illumination system consists of narrowband blue, ultraviolet, and other discrete wavelength light-emitting-diode (LED) sources and white-light LED sources designed to produce consistently spatially stable light. White LEDs provide illumination for the measurement of reflectance spectra, while narrowband blue and UV LEDs are used to excite fluorescence. Each spectral type of LED can be turned on or off depending on the specific remote-sensing process being performed. Uniformity of illumination is achieved by using an array of LEDs and/or an integrating sphere or other diffusing surface. The image plane scanner uses a fore optic with a field of view large enough to provide an entire scan line on the image plane. It builds up a two-dimensional image in pushbroom fashion as the target is scanned across the image plane either by moving the object or moving the fore optic. For fluorescence detection, spectral filtering of a narrowband light illumination source is sometimes necessary to minimize the interference of the source spectrum wings with the fluorescence signal. Spectral filtering is achieved with optical interference filters and absorption glasses. This dual spectral imaging capability will enable the optimization of reflective, fluorescence, and fused datasets as well as a cost-effective design for multispectral imaging solutions. This system has been used in plant stress detection studies and in currency analysis.

Ryan, Robert E.↗

Using synthetic infrared spectra derived from n/k optical constants for standoff detection of chemical deposits

We report results from a recent field experiment to test the validity of using physics-based synthetic infrared spectra to serve as endmembers in a spectral database targeted at chemical deposits. Specifically, the optical constants n and k, (the real and imaginary part of the refractive index) were used to first model infrared reflectance spectra for different thicknesses of chemical layers (e.g. acetaminophen, methylphosphonic acid – MPA, etc.) on various conducting and insulating substrates such as aluminum, wood, and glass. In the experimental portion of the research, thin films of the solid and liquid analytes were deposited onto such substrates to form micron-thick layers of the analytes at different thicknesses: Standoff data from an imaging instrument were then recorded and analyzed to not only identify the different analytes, but also quantify the layer/deposit thickness. To gauge success, the detection results using the synthetic data were compared to the results from hemispherical reflectance (HRF) spectra that were collected for the same sample planchets measured in the field via standoff methods. Preliminary results indicate good agreement between the synthetic reference data as compared to the lab-measured HRF data in terms of their ability to quantitatively reduce longwave infrared data. Specifically, modeled IR spectra for acetaminophen on an aluminum planchet at various thicknesses (1, 2, 5, 10, 15, and 20 µm) were synthesized and compared with standoff field reflectance data as well as HRF laboratory reflectance spectra for two samples: a 5.2 µm- and 12.8 µm-thick layer of acetaminophen on aluminum. Using a first-order approximation, analysis of the field data estimates the thicknesses of the samples to be 2 and 10 µm for the two samples, respectively, while the HRF laboratory data yields thickness estimates of between 5-10 µm and 10 µm, respectively. Both yield reasonable estimates, with the uncertainty most likely due to factors yet to be accounted for in the synthetic spectra such as light scattering.

complex index of refraction, optical constants, hy↗

SIRT1 targeted by miR ‐211‐5p regulated proliferation and apoptosis of Dex‐treated growth plate chondrocytes via mediating SOX2

Abstract Dexamethasone (Dex) is reported to cause bone growth retardation in children, which is associated with the increased apoptosis and decreased proliferation of growth plate chondrocytes. Sirtuin 1 (SIRT1) plays an important role in chondrocyte function and homeostasis. Thus, we further explored the regulatory mechanism of SIRT1 in Dex‐induced growth plate chondrocyte dysfunction. SIRT1 expression was detected in Dex‐treated growth plate chondrocytes using RT‐qPCR and western blot assay. The modulation of SIRT1 on SOX2 expression was evaluated. Besides, we identified that SIRT1 was targeted by miR‐211‐5p using TargetScan and RNA pull‐down assay. A loss‐of‐function assay was performed to evaluate the effects of miR‐211‐5p on Dex‐induced growth plate chondrocyte dysfunction in vitro and in vivo. We found that SIRT1 was downregulated in Dex‐treated growth plate chondrocytes. The expression of SOX2 was upregulated by overexpression SIRT1. Meanwhile, downregulation of SOX2 weakened the positive function of SIRT1 overexpression on Dex‐induced growth plate chondrocytes dysfunction. Subsequently, we confirmed that SIRT1 was targeted by miR‐211‐5p. MiR‐211‐5p inhibitor increased the expression levels of SIRT1 and SOX2, and restored the Dex‐treated growth plate chondrocyte function. Animal assays further demonstrated that the effects of miR‐211‐5p on the growth plate chondrogenesis. In conclusion, our data suggest that SIRT1 exerts a protective effect on growth plate chondrocyte under Dex stimulation. MiR‐211‐5p/SIRT1/SOX2 axis regulates the process of Dex‐inhibited growth plate chondrogenesis.

Cheng, Deliang↗

EWALD: A macromolecular diffractometer for the second target station

Revealing the positions of all the atoms in large macromolecules is powerful but only possible with neutron macromolecular crystallography (NMC). Neutrons provide a sensitive and gentle probe for the direct detection of protonation states at near-physiological temperatures and clean of artifacts caused by x rays or electrons. Currently, NMC use is restricted by the requirement for large crystal volumes even at state-of-the-art instruments such as the macromolecular neutron diffractometer at the Spallation Neutron Source. EWALD’s design will break the crystal volume barrier and, thus, open the door for new types of experiments, the study of grand challenge systems, and the more routine use of NMC in biology. EWALD is a single crystal diffractometer capable of collecting data from macromolecular crystals on orders of magnitude smaller than what is currently feasible. The construction of EWALD at the Second Target Station will cause a revolution in NMC by enabling key discoveries in the biological, biomedical, and bioenergy sciences.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of laser-accelerated proton beams from a 0.5 kJ sub-picosecond laser for radiography applications

Laser-accelerated ion beams show promise for many applications, including high-resolution flash imaging of static or dynamic objects in next-generation radiography to probe materials and plasmas in extreme environments and inertial confinement fusion. To scale up ion beam production for radiography applications, we conducted experiments using sub-picosecond lasers up to 0.5 kJ at the OMEGA-EP facility to characterize proton beams from solid targets, primarily CH/CD sub-micron thin films from which ion beams were also used for static and dynamic radiography for the first time. For standalone sub-micron thin CH films, the highest detected proton energy is in the range of 72–97 MeV. Proton beams with highest energy near or above 60 MeV at full laser energy and similar beam profiles are also measured from low-density CD foams and flat CH foil target of micrometer-scale thickness. The ~ 700–800 nm CH/CD foils achieve the highest ion yield among the targets tested. For sub-micron thin films, the laser prepulse can expand the target and lead to complex interactions, which is simulated using coupled hydrodynamic and two-step kinetic models. Simulations suggest the presence of a micrometer-scale preplasma plateau with near-critical density and further indicate that target normal sheath acceleration, electron heating from Relativistic transparency in the preplasma plateau, and background proton reflection from carbon ion front at the rear side contribute to the resulting proton spectrum from these sub-micron thin targets at various stages. These proton beams show strong potential for radiography and for production of secondary sources.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Single nuclear spin detection and control in a van der Waals material

Optically active spin defects in solids are leading candidates for quantum sensing and quantum networking. Recently, single spin defects were discovered in hexagonal boron nitride (hBN), a layered van der Waals (vdW) material. Owing to its two-dimensional structure, hBN allows spin defects to be positioned closer to target samples than in three-dimensional crystals, making it ideal for atomic-scale quantum sensing, including nuclear magnetic resonance (NMR) of single molecules. However, the chemical structures of these defects remain unknown and detecting a single nuclear spin with a hBN spin defect has been elusive. Here we report the creation of single spin defects in hBN using 13 C ion implantation and the identification of three distinct defect types based on hyperfine interactions. We observed both S = 1/2 and S = 1 spin states within a single hBN spin defect. We demonstrated atomic-scale NMR and coherent control of individual nuclear spins in a vdW material, with a π-gate fidelity up to 99.75% at room temperature. By comparing experimental results with density functional theory (DFT) calculations, we propose chemical structures for these spin defects. Our work advances the understanding of single spin defects in hBN and provides a pathway to enhance quantum sensing using hBN spin defects with nuclear spins as quantum memories.

Quantum metrology↗

Milagro Observations of Potential TeV Emitters

This paper reports the results from three targeted searches of Milagro TeV sky maps: two extragalactic point source lists and one pulsar source list. The first extragalactic candidate list consists of 709 candidates selected from the Fermi-LAT 2FGL catalog. The second extragalactic candidate list contains 31 candidates selected from the TeVCat source catalog that have been detected by imaging atmospheric Cherenkov telescopes (IACTs). In both extragalactic candidate lists Mkn 421 was the only source detected by Milagro. This paper presents the Milagro TeV flux for Mkn 421 and flux limits for the brighter Fermi- LAT extragalactic sources and for all TeVCat candidates. The pulsar list extends a previously published Milagro targeted search for Galactic sources. With the 32 new gamma-ray pulsars identified in 2FGL, the number of pulsars that are studied by both Fermi-LAT and Milagro is increased to 52. In this sample, we find that the probability of Milagro detecting a TeV emission coincident with a pulsar increases with the GeV flux observed by the Fermi-LAT in the energy range from 0.1 GeV to 100 GeV.

Pulsars↗