Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spectroradiometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Derivation of Shortwave Radiometric Adjustments for SNPP and NOAA-20 VIIRS for the NASA MODIS-VIIRS Continuity Cloud Products

Climate studies, including trend detection and other time series analyses, necessarily require stable, well-characterized and long-term data records. For satellite-based geophysical retrieval datasets, such data records often involve merging the observational records of multiple similar, though not identical, instruments. The National Aeronautics and Space Administration (NASA)cloud mask(CLDMSK) and cloud-top and optical properties(CLDPROP) products are designed to bridge the observational records of the Moderate-resolution Imaging Spectroradiometer (MODIS) onboard NASA’s Aqua satellite and the Visible Infrared Imaging Radiometer Suite (VIIRS) onboard the joint NASA/National Oceanic and Atmospheric Administration(NOAA)Suomi National Polar-orbiting Partnership (SNPP)satellite and NOAA’s new generation of operational polar-orbiting weather platforms(NOAA-20+).Early implementations of the CLDPROP algorithms on Aqua MODIS and SNPP VIIRS suffered from large intersensor biases in cloud optical properties that were traced back to relative radiometric inconsistency in analogous shortwave channels on both imagers, with VIIRS generally observing brighter top-of-atmosphere spectral reflectance than MODIS (e.g., up to 5%brighter in the 0.67μm channel). Radiometric adjustment factors for the SNPP and NOAA-20 VIIRS shortwave channels used in the cloud optical property retrievals are derived from an extensive analysis of the overlapping observational records with Aqua MODIS, specifically for homogenous maritime liquid water cloud scenes for which the viewing/solar geometry of MODIS and VIIRS match. Application of these adjustment factors to the VIIRS L1B prior to ingestion into the CLDMSK and CLDPROP algorithms yields improved intersensor agreement, particularly for cloud optical properties

relative radiometry↗

Synergistic Use of Hyperspectral UV-Visible OMI and Broadband Meteorological Imager MODIS Data for a Merged Aerosol Product

The retrieval of optimal aerosol datasets by the synergistic use of hyperspectral ultraviolet(UV)–visible and broadband meteorological imager (MI) techniques was investigated. The Aura Ozone Monitoring Instrument (OMI) Level 1B (L1B) was used as a proxy for hyperspectral UV–visible instrument data to which the Geostationary Environment Monitoring Spectrometer (GEMS) aerosol algorithm was applied. Moderate-Resolution Imaging Spectroradiometer (MODIS) L1B and dark target aerosol Level 2 (L2) data were used with a broadband MI to take advantage of the consistent time gap between the MODIS and the OMI. First, the use of cloud mask information from the MI infrared (IR) channel was tested for synergy. High-spatial-resolution and IR channels of the MI helped mask cirrus and sub-pixel cloud contamination of GEMS aerosol, as clearly seen in aerosol optical depth (AOD) validation with Aerosol Robotic Network (AERONET) data. Second, dust aerosols were distinguished in the GEMS aerosol-type classification algorithm by calculating the total dust confidence index (TDCI) from MODIS L1B IR channels. Statistical analysis indicates that the Probability of Correct Detection (POCD) between the forward and inversion aerosol dust models (DS) was increased from 72% to 94% by use of the TDCI for GEMS aerosol-type classification, and updated aerosol types were then applied to the GEMS algorithm. Use of the TDCI for DS type classification in the GEMS retrieval procedure gave improved single-scattering albedo (SSA) values for absorbing fine pollution particles (BC) and DS aerosols. Aerosol layer height (ALH) retrieved from GEMS was compared with Cloud-Aerosol Lidar with Orthogonal Polarization (CALIOP) data, which provides high-resolution vertical aerosol profile information. The CALIOP ALH was calculated from total attenuated backscatter data at 1064 nm, which is identical to the definition of GEMS ALH. Application of the TDCI value reduced the median bias of GEMS ALH data slightly. The GEMS ALH bias approximates zero, especially for GEMS AOD values of>~0.4 and GEMS SSA values of<~0.95.Finally, the AOD products from the GEMS algorithm and MI were used in aerosol merging with the maximum-likelihood estimation method, based on a weighting factor derived from the standard deviation of the original AOD products. With the advantage of the UV–visible channel in retrieving aerosol properties over bright surfaces, the combined AOD products demonstrated better spatial data availability than the original AOD products, with comparable accuracy. Furthermore, pixel-level error analysis of GEMS AOD data indicates improvement through MI synergy.

aerosol↗

The NASA MODIS-VIIRS Continuity Cloud Optical Properties Products

The NASA Aqua MODIS and Suomi National Polar-Orbiting Partnership (SNPP) Visible Infrared Imaging Radiometer Suite (VIIRS) climate data record continuity cloud properties products (CLDPROP) were publicly released in April 2019 with an update later that year (Version 1.1). These cloud products, having heritage with the NASA Moderate-resolution Imaging Spectroradiometer (MODIS) MOD06 cloud optical properties product and the NOAA GOES-R Algorithm Working Group (AWG) Cloud Height Algorithm (ACHA), represent an effort to bridge the multispectral imager records of NASA’s Earth Observing System (EOS) and NOAA’s current generation of operational weather satellites to achieve a continuous, multi-decadal climate data record for clouds that can extend well into the 2030s. CLDPROP offers a “continuity of approach,” applying common algorithms and ancillary datasets to both MODIS and VIIRS, including utilizing only a subset of spectral channels available on both sensors to help mitigate instrument differences. The initial release of the CLDPROP_MODIS and CLDPROP_VIIRS data records spans the SNPP observational record (2012-present). Here, we present an overview of the algorithms and an evaluation of the intersensor continuity of the core CLDPROP_MODIS and CLDPROP_VIIRS cloud optical property datasets, i.e., cloud thermodynamic phase, optical thickness, effective particle size, and derived water path. The evaluation includes analyses of pixel-level MODIS/VIIRS co-locations as well as spatial and temporal aggregated statistics, with a focus on identifying and understanding the root causes of individual dataset discontinuities. The results of this evaluation will inform future updates to the CLDPROP products and help scientific users determine the appropriate use of the product datasets for their specific needs.

satellite remote sensing↗

Cloud-Precipitation Hybrid Regimes and their Projection onto IMERG Precipitation Data

We extend and enhance the concept of the Cloud Regimes (CRs) developed from two-dimensional joint histograms of cloud optical thickness and cloud top pressure from the Moderate Resolution Imaging Spectroradiometer (MODIS), by adding precipitation information in order to better understand cloud-precipitation relationships. Taking advantage of the high-resolution Integrated Multi-satellitE Retrievals for GPM (IMERG) precipitation dataset, cloud-precipitation “hybrid” regimes are derived by implementing the k-means clustering algorithm with advanced initialization and objective measures to determine the most optimal clusters. By expressing precipitation rates within 1-degree grid cell as histograms and making choices on the relative weight of cloud and precipitation, we could obtain several editions of hybrid cloud-precipitation regimes (CPRs), and examine their characteristics. In the deep tropics, when precipitation is weighted weakly, the cloud part of the hybrid entroids resembles the centroid of cloud-only regimes, but still tightens the cloud-precipitation relationship by decreasing the precipitation variability of each regime. As precipitation weight progressively increases, the shape of the cloudy part of the hybrid centroids becomes blunter, while the precipitation part of the centroids sharpens. In the case where cloud and precipitation are weighted equally, the CPRs representing high clouds with intermediate to heavy precipitation exhibit distinct features in the precipitation parts of the centroids, which allows us to project them onto the 30-minly IMERG domain. Such a projection can be used to overcome the temporal sparseness of MODIS cloud observations, which leads to great application potential for various convection-focused studies, including diurnal cycle analysis.

cloud-precipitation↗

Latest Progress and Results in LEO-GEO and GEO-GEO Stereo AMVs

Atmospheric motion vectors (AMVs), derived by tracking patterns, represent the winds in a layer characteristic of the pattern. AMV height (or pressure), important for applications in atmospheric research and operational meteorology, is usually assigned using observed IR brightness temperatures with a modeled atmosphere and can be inaccurate. Stereoscopic tracking provides a direct geometric height measurement of the pattern that an AMV represents. We extend our previous work with multi-angle imaging spectro–radiometer (MISR) and GOES to moderate resolution imaging spectroradiometer (MODIS) and the GOES-R series advanced baseline imager (ABI). MISR is a unique satellite instrument for stereoscopy with nine angular views along track, but its images have a narrow (380 km) swath and no thermal IR channels. MODIS provides a much wider (2330 km) swath and eight thermal IR channels that pair well with all but two ABI channels, offering a rich set of potential applications. Given the similarities between MODIS and VIIRS, our methods should also yield similar performance with VIIRS. Our methods, as enabled by advanced sensors like MODIS and ABI, require high-accuracy geographic registration in both systems but no synchronization of observations. AMVs are retrieved jointly with their heights from the disparities between triplets of ABI scenes and the paired MODIS granule. We validate our retrievals against MISR-GOES retrievals, operational GOES wind products, and by tracking clear-sky terrain. We demonstrate that the 3D-wind algorithm can produce high-quality AMV and height measurements for applications from the planetary boundary layer (PBL) to the upper troposphere, including cold-air outbreaks, wildfire smoke plumes, and hurricanes.

Atmospheric motion vectors↗

Vegetation Monitoring Optimization with Normalized Difference Vegetation Index and Evapotranspiration Using Remote Sensing Measurements and Land Surface Models Over East Africa

The majority of people in East Africa rely on the agro-pastoral system for their livelihood, which is highly vulnerable to droughts and flooding. Agro-pastoral droughts are endemic to the region and are considered the main natural hazard that contributes to food insecurity. Drought begins with rainfall deficit, gradually leading to soil moisture deficit, higher land surface temperature, and finally impacts to vegetation growth. Therefore, monitoring vegetation conditions is essential in understanding the progression of drought, potential effects on food security, and providing early warning information needed for drought mitigation decisions. Because vegetation processes couple the land and atmosphere, monitoring of vegetation conditions requires consideration of both water provision and demand. While there is consensus in using either the Normalized Difference Vegetation Index (NDVI) or evapotranspiration(ET) for vegetation monitoring, a comprehensive assessment optimizing the use of both has not yet been done. Moreover, the evaluation methods for understanding the relationships between NDVI and ET for vegetation monitoring are also limited. Taking these gaps into account we have developed a framework to optimize vegetation monitoring using both NDVI and ET by identifying where they perform the best by using triple collocation and cross-correlation methods. We estimated the random error structure in Moderate Resolution Imaging Spectroradiometer (MODIS) NDVI; ET from the Operational Simplified Surface Energy Balance (SSEBop) model; and ET from land surface models (LSMs). LSM ET and SSEBop ET have been found to be better indicators for vegetation monitoring during extreme drought events, while NDVI could provide better information on vegetation condition during wetter than normal conditions. The random error structures of these variables suggest that LSM ET is most likely to provide important information for vegetation monitoring over low and high ends of the vegetation fraction areas. Over moderate vegetative areas, any of these variables could provide important vegetation information for drought characterization and food security assessments. While this study provides a framework for optimizing vegetation monitoring for drought and food security assessments over East Africa, the framework can be adopted to optimize vegetation monitoring over any other drought and food insecure region of the world.

triple collocation↗

Montana Water Resources: Developing a Composite Moisture Index Utilizing NASA Earth Observations for Drought Monitoring in Montana and the Missouri River Basin

The Missouri River Basin provides irrigation water for a substantial part of the domestic agricultural sector within the United States. Drought events pose a significant threat to economic livelihoods of dependent individuals, industries, and ecosystems (e.g., farmers, local tribes, hydroelectric power, wildlife). In 2017 alone, the Missouri River Basin experienced a severe drought that resulted in a $2.6 billion loss to the U.S. Northern Plains. In response to such events, organizations throughout the basin, such as the Montana Climate Office, have dedicated efforts for drought monitoring and communicating relevant information to local stakeholders. In an effort to aid regional decision-making capabilities, the project team partnered with the Montana Climate Office, NOAA National Weather Service (NWS) Missouri Basin River Forecast Center, and NOAA Regional Climate Services, Central Region to create a monthly Composite Moisture Index (CMI) that relies on NASA Earth observations from the Terra Moderate Resolution Imaging Spectroradiometer (MODIS) and the Soil Moisture Active Passive (SMAP) mission. From these satellites, as well as the NOAA NWS National Operational Hydrologic Remote Sensing Center Snow Data Assimilation System (SNODAS), our team aggregated climate datasets including soil moisture, snow cover, snow depth, and snow water equivalent to compute a CMI that indicates regional moisture conditions during the winter months. The March CMI values produced over the Missouri River headwater subbasin strongly correlate (r = 0.75) with spring and early summer stream discharge, demonstrating the use of this metric to indicate moisture conditions for the snowmelt and growing seasons.

DEVELOP Tech Paper↗

Air Pollution Trends Measured From Terra: CO and AOD Over Industrial, Fire-prone, and Background Regions

Following past studies to quantify decadal trends in global carbon monoxide (CO) using satellite observations, we update estimates and find a CO trend in column amounts of about −0.50 % per year between 2002 to 2018, which is a deceleration compared to analyses performed on shorter records that found −1 % per year. Aerosols are co-emitted with CO from both fires and anthropogenic sources but with a shorter lifetime than CO. A combined trend analysis of CO and aerosol optical depth (AOD) measurements from space helps to diagnose the drivers of regional differences in the CO trend. We use the long-term records of CO from the Measurements of Pollution in the Troposphere (MOPITT) and AOD from the Moderate Resolution Imaging Spectroradiometer (MODIS) instrument. Other satellite instruments measuring CO in the thermal infrared, AIRS, TES, IASI, and CrIS, show consistent hemispheric CO variability and corroborate results from the trend analysis performed with MOPITT CO. Trends are examined by hemisphere and in regions for 2002 to 2018, with uncertainties quantified. The CO and AOD records are split into two sub-periods (2002 to 2010 and 2010 to 2018) in order to assess trend changes over the 16 years. We focus on four major population centers: Northeast China, North India, Europe, and Eastern USA, as well as fire-prone regions in both hemispheres. In general, CO declines faster in the first half of the record compared to the second half, while AOD trends show more variability across regions. We find evidence of the atmospheric impact of air quality management policies. The large decline in CO found over Northeast China is initially associated with an improvement in combustion efficiency, with subsequent additional air quality improvements from 2010 onwards. Industrial regions with minimal emission control measures such as North India become more globally relevant as the global CO trend weakens. We also examine the CO trends in monthly percentile values to understand seasonal implications and find that local changes in biomass burning are sufficiently strong to counteract the global downward trend in atmospheric CO, particularly in late summer.

carbon monoxide↗

MODIS MOD21 Land Surface Temperature and Emissivity Algorithm Theoretical Basis Document

This document outlines the theory and methodology for generating the Moderate Resolution Imaging Spectroradiometer (MODIS) Level-2 daily daytime and nighttime 1-km land surface temperature (LST) and emissivity product using the Temperature Emissivity Separation (TES) algorithm. The MODIS-TES (MOD21_L2) product, will include the LST and emissivity for three MODIS thermal infrared (TIR) bands 29, 31, and 32, and will be generated for data from the NASA-EOS AM and PM platforms. This is version 1.0 of the ATBD and the goal is maintain a ‘living’ version of this document with changes made when necessary. The current standard baseline MODIS LST products (MOD11*) are derived from the generalized split-window (SW) algorithm (Wan and Dozier 1996), which produces a 1-km LST product and two classification-based emissivities for bands 31 and 32; and a physics-based day/night algorithm (Wan and Li 1997), which produces a 5-km (C4) and 6-km (C5) LST product and emissivity for seven MODIS bands: 20, 22, 23, 29, 31–33

Hughes, Christopher↗

Sensor Calibration Impacts on Dust Detection Based On MODIS And VIIRS Thermal Emissive Bands

Dust detection using remotely sensed measurements has been one of the challenging problems encountered by atmospheric scientists. MODerate Resolution Imaging Spectroradiometer (MODIS) on the Terra (T)and Aqua (A) platforms have been a versatile sensor for well over 21 and 18 years respectively and have been extremely useful in the retrieval of aerosol information over the entire globe. The MODIS radiances from the Level1B in general are expected to be within 5% accuracy in the reflective wavelengths and within 1% in the thermal emissive wavelengths. In this paper, we evaluate the sensitivity of previously developed dust detection technique based on thermal emissive wavelengths, which correspond to MODIS bands 20, 29, 31, and 32 respectively. The Thermal Emissive Dust Index (TEDI) performed very comparably to the traditional Aerosol Optical Thickness (AOT) retrievals by MODIS reflective channels. Since the MODIS Thermal Emissive Bands (TEB) are well calibrated on-orbit using a BlackBody (BB) source, the calibration of these long wave infrared bands is quite robust. As A-MODIS continues to perform well beyond its designed lifetime of 6 years, the instrument has undergone various levels of degradation during its mission time. As a consequence, it is imperative to check the impacts of calibration on the higher-level retrievals. In this paper, we rigorously analyze the sensitivity of TEDI due to the impact of calibration by the afore-mentioned TEB. The perturbation of the dominant (linear) calibration term demonstrated the following: first, there was a correlation in the sensitivity of the TEDI due to the uncertainty in the linear calibration term. Based on a perturbation in the linear calibration term for all aforementioned bands over a range of ± 5 % yielded the TEDI sensitivity to vary from approximately -3.2 % to about -3.6 %. When considering the uncertainty in each individual band significant changes were observed. The least change was observed for the perturbation in the calibration of band 20 with the TEDI sensitivity and the largest sensitivity in TEDI was observed in the perturbation of band 31 calibration. Thus, in the case of TEDI, noticeable sensitivity due to calibration uncertainty was observed in bands 29, 31, and 32, reiterating the importance of the TEB calibration in these bands. Also, the dust detection scheme based on A-MODIS was successfully transferred to the follow-on sensors such as Suomi (SNPP) and NOAA 20 (N20) VIIRS. The results presented in this paper would be extremely helpful in understanding impacts of calibration on the higher-level products for both current and future missions based on the MODIS heritage. Finally, the work also identifies the importance of radiometric fidelity in maintaining the accuracy of the dust detection. Results presented will show drastic improvement of the Saharan dust detection after the reduction of the electronic crosstalk in the 8.5 μm channel of T-MODIS.

Sriharsha Madhavan↗

Assessing Disaggregated SMAP Soil Moisture Products in the United States

A soil moisture (SM) disaggregation algorithm based on thermal inertia (TI) theory was implemented to downscale the Soil Moisture Active Passive (SMAP) Enhanced product(SPL2SMPE) from 9 km to 1 km over the continental United States. The algorithm applies land surface temperature and normalized difference vegetation index from Moderate Resolution Imaging Spectroradiometer (MODIS) at higher spatial resolution to estimate relative soil wetness within a coarse SMAP grid -this MODIS-derived relative wetness is then used to produce the downscaled SMAP SM. Results from the algorithm were evaluated in terms of their spatiotemporal coverage and accuracy using in situ measurements from SMAP Core Validation Sites (CVS), the US Department of Agriculture Soil Climate Analysis Network (USDA-SCAN), and the National Oceanic and Atmospheric Administration Climate Reference Network(NOAA-CRN). Results were also compared with the baselineSPL2SMPE and the SMAP/Sentinel-1 (SPL2SMAPS) 1kmproduct. Overall, the unbiased root mean square error (ubRMSE)of the disaggregated SM at the CVS using the TI approach is approximately 0.04 m3=m3, which is the SMAP mission requirement for the baseline products. The TI approach out performs the SMAP/Sentinel SL2SMAPS 1km product by approximately0.02 m3=m3. Over the agriculture/crop areas from SCAN and CRN sparse network stations, the TI approach exhibits better ubRMSE compared to SPL2SMPE andSPL2SMAPS byabout0.01 and 0.02 m3=m3, indicating its advantage in these areas. However, a drawback of this approach is that there are data gaps due to cloud cover as optical sensors cannot have a clear view of the land surface.

Soil moisture↗

Comparison of the MODIS and VIIRS Thermal Emissive Band Radiometric Calibration

Moderate Resolution Imaging Spectroradiometer (MODIS) and Visible Infrared Imaging Radiometer Suite (VIIRS) are major instruments for Earth science observations.Nearly 40 MODIS scientific products and a wide range of VIIRS environmental data records are produced using their global observations. The consistency of the MODIS and VIIRS calibrated data is important for the study of Earth science. This article assesses the calibration consistency of the Aqua MODIS and VIIRS thermal emissive band (TEB) data. To remove the impact of the mismatched relative spectral response (RSR) on the comparisons, the simultaneous nadir observation data from the cross-track infrared sounder (CrIS) and the infrared atmospheric sounding interferometer (IASI) are used as references in two different methods to independently verify the consistency. The comparisons of the MODIS and VIIRS TEB calibrated data show that the brightness temperature (BT) differences for comparable bands between MODIS and VIIRS are in general within 0.2 K for BT larger than 230 K. The differences of all comparable MODIS and VIIRS TEBs are consistent over time. MODIS measurements agree better with N20 VIIRS than with Suomi National Polar-orbiting Partnership (S-NPP) VIIRS. The S-NPP VIIRS measurements are higher than N20 VIIRS, within 0.1 Kfor long-wave infrared (LWIR) bands and 0.3 K for band M13.

Calibration↗

Improved Lunar Irradiance Model Using Multiyear MODIS Lunar Observations

The Moderate Resolution Imaging Spectroradiometer (MODIS) instruments on board the Terra and Aqua spacecrafts were launched on December 18, 1999, and May 4, 2002, respectively. One of the features of the MODIS instruments is the ability to perform observations of the lunar surface from its space view (SV) port. This event is scheduled approximately once a month via a spacecraft roll maneuver, which enables the lunar phase to be confined to within 1° for each instrument. The Moon is considered to be an extremely stable reference to monitor the long-term radiometric stability of the reflective solar bands (RSB). Each MODIS instrument can also view the Moon for about four months in a year without a roll maneuver. This is caused by the intrusion of the Moon in the SV. The lunar phase angles of these unscheduled lunar observations are distributed over a wide range varying from approximately 50° to 80° for Terra MODIS and from about -80° to -50° for Aqua MODIS, where the positive phase angle refers to a waning Moon, while the negative phase angle corresponds to a waxing Moon. Together, the scheduled and unscheduled lunar observations are used to monitor the long-term radiometric stability of the RSB. Of the several challenges involved in the modeling of the lunar optical properties, such as its absolute brightness, a number of optical and view geometry effects need to be considered. These effects are much easier to characterize for the scheduled observations due to confinement of the lunar phase angles compared to those for the unscheduled intrusions of the Moon in the SV. Nevertheless, it is still a challenge to remove the view geometry effect in the calibration coefficients derived from the scheduled lunar observations and even more challenging for the unscheduled lunar intrusions. In this work, the lunar absolute irradiance is modeled using known attributes and from the lunar observations by the two MODIS instruments from the time period between the years 2005 and 2012.

Calibration↗

Modeling Spectral Degradation of MODIS and VIIRS Solar Diffusers

Solar diffusers (SDs) onboard the Moderate Resolution Imaging Spectroradiometer (MODIS) on Terra and Aqua spacecraft and the Visible Infrared Imaging Radiometer Suite (VIIRS) on SNPP and NOAA-20 spacecraft have been used as the primary onboard radiometric calibrator for reflective solar bands and their spectral reflectance is known to degrade on-orbit. All of the solar diffusers on these instrument show faster degradation of reflectance in the 0.4 to 0.6 µm channels than the longer wavelength channels. The spectral degradation of these SDs is due to the surface roughness growth under the exposure to solar UV and energetic particle radiation in space. In this paper, the origin of SD degradation is modeled by the physics-based Surface Roughness-induced Rayleigh Scattering (SRRS) model. The longterm growths of surface roughness of the SD on these instruments are characterized to show the consistency of SD roughness growth rates between Terra/Aqua MODIS and SNPP/NOAA-20 VIIRS. There was coincidental flattening or reverse in the growth trend of the surface roughness for the Terra/Aqua MODIS and SNPP VIIRS SDs, which can be due to the space weather variation. The applicability of the SRRS model is demonstrated with the long term spectral reflectance data from independent spaceborne SDs.

Calibration↗

Modeling transmittance of MODIS solar diffuser stability monitor sun view screen

Earlier work by Sun et al. [2005] modeled the Sun view screen transmittance of the solar diffuser stability monitor (SDSM) on Moderate Resolution Imaging Spectroradiometer (MODIS) which explains the oscillatory pattern in the Terra/Aqua MODIS SDSM Sun view response collected during the post-launch yaw maneuvers. The SDSM screen consists of small size pinholes which limit the screen transmittance. The SDSM Sun view transmittance pattern is affected by the size and distribution of pinholes, screen thickness, and orientation between the aperture stop and the Sun view screen. Planning of post-launch yaw maneuver test often requires comprehensive angular coverage to resolve the angular variation of the screen transmittance. This paper developed a Gauss-Kronrod quadrature method-based model to simulate the SDSM Sun view transmittance. This method performs iterative integration of the interception area between pinhole and aperture stop which is critical in the screen transmittance calculation. Parametric dependences of the MODIS SDSM Sun view transmittance on various geometric factors such as the pinhole size or spacing and misalignment between the SDSM Sun view screen and aperture stop are studied. The implications for the post-launch yaw maneuver planning to resolve the angular variation of the SDSM Sun view transmittance due to the SDSM Sun view screen misalignment are discussed.

MODIS↗

Stability Assessment of OCO-2 Radiometric Calibration Using Aqua MODIS as a Reference

With three imaging grating spectrometers, the Orbiting Carbon Observatory-2 (OCO-2)measures high spectral resolution spectra (λ/∆λ≈19,000) of reflected solar radiation within the molecular oxygen (O2) A-band at 0.765 μm and two carbon dioxide (CO2) bands at 1.61 and 2.06 μm. OCO-2 uses onboard lamps with a reflective diffuser, solar observations through a transmissive diffuser, lunar measurements, and surface targets for radiometric calibration and validation. Separating calibrator aging from instrument degradation poses a challenge to OCO-2. Here we present a methodology for trending the OCO-2 Build 8R radiometric calibration using OCO-2 nadir observations over eight desert sites and nearly simultaneous observations from Moderate Resolution Imaging Spectroradiometer (MODIS) with sensor viewing zenith angles of 15 ± 0.5°. For the O2 A-band, this methodology is able to quantify a drift of−0.8 ± 0.1% per year and capture a small error in correcting the aging of the solar calibrator. For the other two OCO-2 bands, no measurable changes were seen, indicating less than 0.1% and less than 0.3% per year drift in the radiometric calibration of Band 2 and Band 3, respectively.

radiometric calibration↗