Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sample”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Uncertainties in Coastal Ocean Color Products: Impacts of Spatial Sampling

With increasing demands for ocean color (OC) products with improved accuracy and well characterized, per-retrieval uncertainty budgets, it is vital to decompose overall estimated errors into their primary components. Amongst various contributing elements (e.g., instrument calibration, atmospheric correction, inversion algorithms) in the uncertainty of an OC observation, less attention has been paid to uncertainties associated with spatial sampling. In this paper, we simulate MODIS (aboard both Aqua and Terra) and VIIRS OC products using 30 m resolution OC products derived from the Operational Land Imager (OLI) aboard Landsat-8, to examine impacts of spatial sampling on both cross-sensor product intercomparisons and in-situ validations of R(sub rs) products in coastal waters. Various OLI OC products representing different productivity levels and in-water spatial features were scanned for one full orbital-repeat cycle of each ocean color satellite. While some view-angle dependent differences in simulated Aqua-MODIS and VIIRS were observed, the average uncertainties (absolute) in product intercomparisons (due to differences in spatial sampling) at regional scales are found to be 1.8%, 1.9%, 2.4%, 4.3%, 2.7%, 1.8%, and 4% for the R(sub rs)(443), R(sub rs)(482), R(sub rs)(561), R(sub rs)(655), Chla, K(sub d)(482), and b(sub bp)(655) products, respectively. It is also found that, depending on in-water spatial variability and the sensor's footprint size, the errors for an in-situ validation station in coastal areas can reach as high as +/- 18%. We conclude that a) expected biases induced by the spatial sampling in product intercomparisons are mitigated when products are averaged over at least 7 km × 7 km areas, b) VIIRS observations, with improved consistency in cross-track spatial sampling, yield more precise calibration/validation statistics than that of MODIS, and c) use of a single pixel centered on in-situ coastal stations provides an optimal sampling size for validation efforts. These findings will have implications for enhancing our understanding of uncertainties in ocean color retrievals and for planning of future ocean color missions and the associated calibration/validation exercises.

Coastal ocean color↗

Lunar Sample Return Entry Systems Analysis

The Lunar Prospector and Clementine missions have revealed deposits of water-ice located at the South Pole-Aitken Basin of the lunar surface. Due to the scarce amount of previous successful sample return missions and the recent discovery of water-ice, the National Research Council (NRC) Decadal Survey recommended prioritizing the development of a Lunar Sample Return Mission Architecture. The NRC Decadal survey ranked the return of cryogenic samples that could potentially aid in current scientific investigations and identify sites for in-situ resource utilization to support future exploration missions. This study aims to identify the key technical challenges and operational constraints involved in returning cryogenic samples in pristine condition. A detailed classification of defined ground rules and assumptions, justification of mission events and high level functional requirements reinforces the proposed concept of operations. In support of the drafted architecture, a comprehensive analysis on design and environmental constraints are documented for the Earth return vehicle, sample container and thermal protection entry system. The design and thermal analysis is comprised of quantitative dimensions for mass and volume, flight performance parameters and thermal system performance limitations. Further refinement of the high level functional requirements is imperative for determining the optimal approach for returning cryopreserved lunar samples.

Lunar Sample Return↗

Dynamic Simulation Probabalistic Risk Assessment Model for an Enceladus Sample Return Mission

Enceladus, a moon of Saturn, has geyser-like jets that spray plumes of material into orbit. These jets could enable a free-flying spacecraft to collect samples and return them to Earth for study to determine if they contain the building blocks of life. The Office of Planetary Protection at NASA requires containment of any unsterilized samples and prohibits destructive impact of the spacecraft upon return to Earth, with a sample release probability of less than 1 in 1,000,000 as a recommended goal. This paper describes a probabilistic risk assessment model that uses dynamic simulation techniques to capture the physics-based, time- and state-dependent interactions between the sample return system and the environment, which drive the risk of sample release. The dynamic approach uses a Monte Carlo-style simulation to integrate the many phases and sources of risk for a sample return mission. The model is used to assess the achievability of the planetary protection reliability goal. This is accomplished by performing sensitivity studies assessing the impact of modeling assumptions to identify where uncertainties drive the risk. These results, in turn, are used to examine the feasibility of meeting key design and performance parameters that are needed to achieve the reliability goal for a given architecture with existing technologies.

Dynamic Simulation↗

Martian Brines in Ancient Salt Lake Beds – A High Priority Target for Mars Sample Return

Mars hosts over 600 chloride deposits as identified from orbital imagery [1-3], including deposits in settings resembling dry, evaporite lacustrine bedforms on Earth. A Mars sample return mission to one of these salt lake beds has a strong potential to directly sample present-day brines originating from ancient martian surface fluids, allowing direct laboratory investigation into fluids, atmosphere, and either potential biology or prebiological conditions on the martian surface at the Noachian through the Hesperian epochs. These sites are extraordinarily well suited for sample return missions because they are favorable for landing and for drill-based sampling, and preserve samples of parent water bodies, including dissolved atmosphere and potential well-preserved biological remains. Such a mission would provide a foundational set of reference samples for understanding Mars’ physiochemical and pre-/biological history, likely to be investigated in depth for generations to come.

brine↗

Sample Return and Preliminary Examination Timeline for the OSIRIS-REx Mission

NASA’s OSIRIS-REx spacecraft collected a sample of asteroid (101955) Bennu on October 20, 2020, using the Touch-and-Go Sample Acquisition Mechanism (TAGSAM) [1,2,3]. After sample acquisition, the TAGSAM collection head was stowed in the Sample Return Capsule (SRC; Fig. 1) for transport back to Earth. On September 24, 2023, the OSIRIS-Rex spacecraft will fly by Earth and release the SRC, which will land at the Utah Test and Training Range (UTTR). The sample will be transported to the OSIRIS-REx curation facility, located within NASA’s Johnson Space Center (JSC), where it will be examined, cataloged, and allocated for scientific analyses. Here we describe the timeline of operations for the return, recovery, and initial characterization of the Bennu sample.

Asteroid↗

Elevating the Quality of Space Omics Sequencing Data: Innovations and Methodologies from NASA GeneLab Sample Processing Laboratory

NASA’s GeneLab, part of the NASA Open Science Data Repository, is a space-related database that hosts a diverse range of transcriptomics, proteomics, epigenomics and genomics data. The NASA GeneLab Sample Processing Laboratory (SPL) generates omics data from biological experiments conducted aboard the International Space Station, Space Shuttle and space related ground experiments, this omics data then hosted on the GeneLab repository. Samples generated such experiments pose numerous technical challenges such as small experimental sample size, variance in dissection times, limited tissue preservation methods, prolonged storage time, and more. GeneLab SPL team had developed specialized expertise in nucleic acid extraction, library preparation and sequencing of such biological samples via extensive training and years of experience. In order to ensure data accuracy and consistency across experiments, SPL has developed standardized protocols for each species and tissue type. These protocols in conjunction with quality control metrics and data standards are crucial in generating of high-quality data. SPL protocols and standards have been developed in collaboration with the scientific community and had been made publicly available on the GeneLab portal, guaranteeing comparability of datasets across spaceflight experiments. To ensure reliability of data generation, SPL leverages cutting-edge innovations in laboratory automation for sample processing. By leveraging these state-of-the-art platforms, SPL achieves high levels of data reproducibility while significantly minimizing sources of bias and variability, especially across experiments with large numbers of samples. Over the past few years, the space biology investigator community has accessed SPL-generated data from the Open Science Data Repository for a myriad of data re-analysis and re-use studies. We observe a trend that in-house SPL-generated data consistently outperforms outsourced sequencing data in terms of technical standards, quality control metrics, timeliness of data delivery, and sequencing and reagent efficiency. Superior data generation has and will continue to enable discoveries in disease, diagnostic tools, and the biological effects of long duration spaceflight.

GeneLab↗

Elevating the Quality of Space Omics Sequencing Data: Innovations and Methodologies from NASA GeneLab Sample Processing Laboratory

NASA’s GeneLab, part of the NASA Open Science Data Repository, is a space-related database that hosts a diverse range of transcriptomics, proteomics, epigenomics and genomics data. The NASA GeneLab Sample Processing Laboratory (SPL) generates omics data from biological experiments conducted aboard the International Space Station, Space Shuttle and space related ground experiments, this omics data then hosted on the GeneLab repository. Samples generated such experiments pose numerous technical challenges such as small experimental sample size, variance in dissection times, limited tissue preservation methods, prolonged storage time, and more. GeneLab SPL team had developed specialized expertise in nucleic acid extraction, library preparation and sequencing of such biological samples via extensive training and years of experience. In order to ensure data accuracy and consistency across experiments, SPL has developed standardized protocols for each species and tissue type. These protocols in conjunction with quality control metrics and data standards are crucial in generating of high-quality data. SPL protocols and standards have been developed in collaboration with the scientific community and had been made publicly available on the GeneLab portal, guaranteeing comparability of datasets across spaceflight experiments. To ensure reliability of data generation, SPL leverages cutting-edge innovations in laboratory automation for sample processing. By leveraging these state-of-the-art platforms, SPL achieves high levels of data reproducibility while significantly minimizing sources of bias and variability, especially across experiments with large numbers of samples. Over the past few years, the space biology investigator community has accessed SPL-generated data from the Open Science Data Repository for a myriad of data re-analysis and re-use studies. We observe a trend that in-house SPL-generated data consistently outperforms outsourced sequencing data in terms of technical standards, quality control metrics, timeliness of data delivery, and sequencing and reagent efficiency. Superior data generation has and will continue to enable discoveries in disease, diagnostic tools, and the biological effects of long duration spaceflight.

GeneLab↗

The Scientific Significance of Potential Samples From the Jezero Crater Rim

The Mars 2020 Perseverance rover has been exploring Jezero crater, Mars to characterize the geology,assess the potential for rocks to represent ancient habitable environments and/or preserve biosignatures, and collect a suite of scientifically compelling samples for return to Earth (Farleyet al.,2020).Thus far, Perseverance has collected samples that represent the diversity of igneous materials encountered on the crater floor and a suite of aqueously deposited sedimentary rocks from the fanand margin units(Simon et al., 2023; Bosak et al., 2024). When the rover ascendsthe crater rimit will encounter rocktypesthat are not included in the current sample cache. These include rocks fromthe Noachian whose mineralogical, geochemical, and geochronological recordswould greatly expand our understanding of early Mars. Some of the exposures are understood to come from subsurface aquifers that may represent the most ancient potentially habitablesubsurfaceenvironmentson Mars(Ehlmann et al., 2024). Samples ofthese rocks will add uniquescientific value tothe sample cache and to the Mars sample returnprogramby addressing outstanding questions in Mars science including potential habitability and how the climate and the interior of the planet evolved through time.

Mars 2020↗

Per- and Polyfluoroalkyl Substances Confirmatory Sampling Report, South Repeater Building (SWMU 121), Kennedy Space Center, Florida

This Per- and Polyfluoroalkyl Substances (PFAS) Confirmatory Sampling (CS) Report was prepared by AECOM Technical Services, Inc. (AECOM) for the National Aeronautics and Space Administration (NASA) under Contract 80KSC019D0010, Task Order 80KSC021F0096. The purpose of this report is to document CS activities at the South Repeater Building, Solid Waste Management Unit (SWMU) 121, formerly known as the Area 3 Repeater Building (A3RB). A Phase I SWMU Assessment and Confirmatory Sampling Report (NASA 2019) and a Phase II and III SWMU Assessment and Confirmatory Sampling Report (NASA 2022b) were previously submitted detailing Center-Wide assessment activities performed at the John F. Kennedy Space Center (KSC) in Florida that identified 33 locations of concern and 19 areas of potential concern at KSC associated with the storage, use, or release of materials containing PFAS. A review of the analytical results from investigation derived waste samples collected in 2020 from the South Repeater Building area indicated concentrations of perfluorooctanesulfonic acid (PFOS) were above Florida Department of Environmental Protection (FDEP) provisional Groundwater Cleanup Target Levels of 70 nanograms per liter (ng/L) at a concentration of 1,750 ng/L. Following this review, the KSC Fire Chief was contacted; the Chief recalled fighting a brush fire in 1998 in the area, during which an unknown volume of aqueous film-forming foam was used to extinguish the fire. The Phase II and Phase III SWMU Assessment Report recommended this area proceed to CS. Historical results in this area are provided in Appendix A . PFAS CS activities were contracted at the South Repeater Building. Initial CS activities were conducted in accordance with the PFAS Assessment and Mitigation Work Plan (AECOM 2022), which was submitted to the NASA Remediation Project Management team and accepted by the team on November 1 and 8, 2021. The objectives of the PFAS CS were to: - - Confirm and begin to assess the extent of PFAS affected media in the South Repeater Building area. - - Identify locations for groundwater, soil, surface water, and soil core sampling. - - Qualitatively characterize the migration potential of released PFAS to environmental media (soil, groundwater, and surface water). The following activities were completed to meet the PFAS CS objectives: - - Installation of monitoring wells via direct push technology (DPT) and rotosonic techniques - - Groundwater, soil, and surface water sampling - - Collection of soil cores to evaluate site lithology - - Development of initial PFAS plume characterization

PFAS↗

Molecular Inventory and Comparative Organic Profiling of A Homogenized Aggregate Sample From Asteroid (101955) Bennu

Evaluating the distribution and diversity of solvent-soluble organic molecules in extraterrestrial materials provide information about the physicochemical environments where prebiotic chemistry occurred and is essential for assessing the inventory of prebiotic compounds available to the early Earth. In this work, we conducted a comprehensive molecular characterization of solvent-soluble organic compounds in a homogenized aggregate sample (ID: OREX-800107-128) of unsorted regolith from asteroid (101955) Bennu returned by NASA’s OSIRIS-REx mission. Using two-dimensional gas chromatography coupled with high-resolution time-of-flight mass spectrometry (GC×GC-HRMS), we identified 87 organic compounds across several molecular classes, including alkanes, polycyclic aromatic hydrocarbons, and nitrogen-, oxygen-, and sulfur-bearing species. Comparison with the organic inventory of CI (Orgueil), C2-ungrouped (Tagish Lake and Tarda), and CM2 (Murchison) carbonaceous chondrites revealed that Bennu sample OREX-800107-128 is most similar to Tagish Lake and Tarda yet compositionally distinct from all of these meteorites. This Bennu sample exhibits a relatively high abundance of low-molecular-weight aromatics (e.g., toluene), pyridine derivatives, and sulfur species such as dimethyl sulfite, consistent with episodic low-temperature aqueous alteration. The presence of these organic compounds suggests that this material experienced chemically diverse processes in the parent body conducive to complex organic synthesis, including aldol condensation reactions responsible for N- and O-bearing compounds. We also compared the molecular distributions of this Bennu sample and previously analyzed samples from (162173) Ryugu to assess potential common origins between these two carbonaceous asteroids. Bennu shows more chemically diverse and nitrogen-rich organic materials than Ryugu. While both asteroids share broadly similar primitive compositions, the observed chemical differences indicate distinct evolutionary histories within a likely common formation environment though whether Bennu and Ryugu derive from a single compositionally heterogeneous parent body or from multiple closely related progenitors remains unresolved. Further detailed comparative analyses of material from Bennu, Ryugu, and specific carbonaceous meteorites (e.g., Tagish Lake and Tarda) will provide new insights into how the N-rich molecular profile observed in Bennu samples was formed and evolved in the outer Solar System.

sample return↗

On sampling fractions and electron shower shapes

We study the usage of various definitions of sampling fractions in understanding electron shower shapes in a sampling multilayer electromagnetic calorimeter. We show that the sampling fractions obtained by the conventional definition (I) of (average observed energy in layer)/(average deposited energy in layer) will not give the best energy resolution for the calorimeter. The reason for this is shown to be the presence of layer by layer correlations in an electromagnetic shower. The best resolution is obtained by minimizing the deviation from the total input energy using a least squares algorithm. The 'sampling fractions' obtained by this method (II) are shown to give the best resolution for overall energy. We further show that the method (II) sampling fractions are obtained by summing the columns of a non-local {lambda} tensor that incorporates the correlations. We establish that the sampling fractions (II) cannot be used to predict the layer by layer energies and that one needs to employ the full {lambda} tensor for this purpose. This effect is again a result of the correlations.

43 PARTICLE ACCELERATORS↗

Sampling and analysis of cyber media to determine whether it meets the definition of a hazardous waste - 15208

Sandia National Laboratories, New Mexico (SNL/NM) was tasked to support The Department of Energy (DOE) in the disposal of classified cyber media. Certain cyber media have lead and silver. Various cyber media types were identified because they may have a hazardous waste characteristic. The overall objective of this sampling effort is to obtain representative samples of specific types of cyber media and analyze those samples to collect data to determine definitively if the cyber media are hazardous waste. Ten different samples were obtained from the unclassified waste stream and shredded to meet the sampling criteria. The samples were shipped to an offsite analytical laboratory with a Chain of Custody. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Resonant ultrasound spectroscopy for materials with high damping and samples of arbitrary geometry

This paper describes resonant ultrasound spectroscopy (RUS) as a powerful and established technique for measuring elastic constants of a material with general anisotropy. The first step of this technique consists of extracting resonance frequencies and damping from the vibrational frequency spectrum measured on a sample with free boundary conditions. An inversion technique is then used to retrieve the elastic tensor from the measured resonance frequencies. As originally developed, RUS has been mostly applicable to (i) materials with small damping such that the resonances of the sample are well separated and (ii) samples with simple geometries for which analytical solutions exist. In this paper, these limitations are addressed with a new RUS approach adapted to materials with high damping and samples of arbitrary geometry. Resonances are extracted by fitting a sum of exponentially damped sinusoids to the measured frequency spectrum. The inversion of the elastic tensor is achieved with a genetic algorithm, which allows searching for a global minimum within a discrete and relatively wide solution space. First, the accuracy of the proposed approach is evaluated against numerical data simulated for samples with isotropic symmetry and transversely isotropic symmetry. Subsequently, the applicability of the approach is demonstrated using experimental data collected on a composite structure consisting of a cylindrical sample of Berea sandstone glued to a large piezoelectric disk. In the proposed experiments, RUS is further enhanced by the use of a 3-D laser vibrometer allowing the visualization of most of the modes in the frequency band studied.

36 MATERIALS SCIENCE↗

Profiling of adrenocorticotropic hormone and arginine vasopressin in human pituitary gland and tumor thin tissue sections using droplet-based liquid-microjunction surface-sampling-HPLC–ESI-MS–MS

Described here are the results from the profiling of the proteins arginine vasopressin (AVP) and adrenocorticotropic hormone (ACTH) from normal human pituitary gland and pituitary adenoma tissue sections using a fully automated droplet-based liquid microjunction surface sampling-HPLC-ESI-MS/MS system for spatially resolved sampling, HPLC separation, and mass spectral detection. Excellent correlation was found between the protein distribution data obtained with this droplet-based liquid microjunction surface sampling-HPLC-ESI-MS/MS system and those data obtained with matrix assisted laser desorption ionization (MALDI) chemical imaging analyses of serial sections of the same tissue. The protein distributions correlated with the visible anatomic pattern of the pituitary gland. AVP was most abundant in the posterior pituitary gland region (neurohypophysis) and ATCH was dominant in the anterior pituitary gland region (adenohypophysis). The relative amounts of AVP and ACTH sampled from a series of ACTH secreting and non-secreting pituitary adenomas correlated with histopathological evaluation. ACTH was readily detected at significantly higher levels in regions of ACTH secreting adenomas and in normal anterior adenohypophysis compared to non-secreting adenoma and neurohypophysis. AVP was mostly detected in normal neurohypophysis as anticipated. This work demonstrates that a fully automated droplet-based liquid microjunction surface sampling system coupled to HPLC-ESI-MS/MS can be readily used for spatially resolved sampling, separation, detection, and semi-quantitation of physiologically-relevant peptide and protein hormones, such as AVP and ACTH, directly from human tissue. In addition, the relative simplicity, rapidity and specificity of the current methodology support the potential of this basic technology with further advancement for assisting surgical decision-making.

59 BASIC BIOLOGICAL SCIENCES↗

IR Thermographic Analysis of 3D Printed CFRP Reference Samples with Back-Drilled and Embedded Defects

Carbon-fiber composite structures may demonstrate a defective behavior due to manufacturing induced anomalies (delamination, dis-bonds) or service related defectives (impact damage, water ingress). Thus, there is a need for a relatively fast and low cost non-intrusive testing schemes such as infrared thermography (IRT). Still, thermography testing requires calibrated samples and coupons to yield best results. The presented research demonstrates the novel use of 3D printing technology to generate IRT calibration samples. In this text, two carbon fiber reinforced polymer samples are 3D printed; the first mimics a 'back-drilled holes' type coupons, while the other is designed to embed air pockets similar to Teflon inserts. The generated samples are then tested using two IRT modalities; namely pulse thermography and lock-in thermography. Furthermore, the resulted thermograms are processed using a principle component analysis, to help highlight the variance of defectives in a consistent manner among the samples. This research findings offer insights on the variation of detectability between embedded and back-printed samples, which might be due to the inserts thickness.

36 MATERIALS SCIENCE↗

Rapid determination of 210 Po in water samples

A new rapid method for the determination of 210 Po in water samples has been developed at the Savannah River National Laboratory (SRNL) that can be used for emergency response or routine water analyses. If a radiological dispersive device (RDD) event or a radiological attack associated with drinking water supplies occurs, there will be an urgent need for rapid analyses of water samples, including drinking water, ground water and other water effluents. Current analytical methods for the assay of 210 Po in water samples have typically involved spontaneous auto-deposition of 210 Po onto silver or other metal disks followed by counting by alpha spectrometry. The auto-deposition times range from 90 minutes to 24 hours or more, at times with yields that may be less than desirable. If sample interferences are present, decreased yields and degraded alpha spectrums can occur due to unpredictable thickening in the deposited layer. Separation methods have focused on the use of Sr Resin, often in combination with 210 Pb analysis. A new rapid method for 210 Po in water samples has been developed at the Savannah River National Laboratory (SRNL) that utilizes a rapid calcium phosphate co-precipitation method, separation using DGA Resin (N,N,N,N-tetraoctyldiglycolamide extractant-coated resin, Eichrom Technologies or Triskem-International), followed by rapid microprecipitation of 210 Po using bismuth phosphate for counting by alpha spectrometry. This new method can be performed quickly with excellent removal of interferences, high chemical yields and very good alpha peak resolution, eliminating any potential problems with the alpha source preparation for emergency or routine samples. A rapid sequential separation method to separate 210 Po and actinide isotopes was also developed. This new approach, rapid separation with DGA Resin plus microprecipitation for alpha source preparation, is a significant advance in radiochemistry for the rapid determination of 210 Po.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Rapid determination of actinides in asphalt samples

A new rapid method for the determination of actinides in asphalt samples has been developed that can be used in emergency response situations or for routine analysis If a radiological dispersive device (RDD), Improvised Nuclear Device (IND) or a nuclear accident such as the accident at the Fukushima Nuclear Power Plant in March, 2011 occurs, there will be an urgent need for rapid analyses of many different environmental matrices, including asphalt materials, to support dose mitigation and environmental clean up. The new method for the determination of actinides in asphalt utilizes a rapid furnace step to destroy bitumen and organics present in the asphalt and sodium hydroxide fusion to digest the remaining sample. Sample preconcentration steps are used to collect the actinides and a new stacked TRU Resin + DGA Resin column method is employed to separate the actinide isotopes in the asphalt samples. The TRU Resin plus DGA Resin separation approach, which allows sequential separation of plutonium, uranium, americium and curium isotopes in asphalt samples, can be applied to soil samples as well.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Rapid determination of actinides in seawater samples

A new rapid method for the determination of actinides in seawater samples has been developed at the Savannah River National Laboratory. The actinides can be measured by alpha spectrometry or inductively-coupled plasma mass spectrometry. The new method employs novel pre-concentration steps to collect the actinide isotopes quickly from 80 L or more of seawater. Actinides are co-precipitated using an iron hydroxide co-precipitation step enhanced with Ti +3 reductant, followed by lanthanum fluoride co-precipitation. Stacked TEVA Resin and TRU Resin cartridges are used to rapidly separate Pu, U, and Np isotopes from seawater samples. TEVA Resin and DGA Resin were used to separate and measure Pu, Am and Cm isotopes in seawater volumes up to 80 L. This robust method is ideal for emergency seawater samples following a radiological incident. It can also be used, however, for the routine analysis of seawater samples for oceanographic studies to enhance efficiency and productivity. In contrast, many current methods to determine actinides in seawater can take 1–2 weeks and provide chemical yields of ~30–60 %. This new sample preparation method can be performed in 4–8 h with tracer yields of ~85–95 %. By employing a rapid, robust sample preparation method with high chemical yields, less seawater is needed to achieve lower or comparable detection limits for actinide isotopes with less time and effort.

61 RADIATION PROTECTION AND DOSIMETRY↗