Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “random testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Parametric study of thermal storage containing rocks or fluid filled cans for solar heating and cooling, phase 2

The test data and an analysis of the heat transfer characteristics of a solar thermal energy storage bed utilizing water filled cans and standard bricks as energy storage medium are presented. This experimental investigation was initiated to find a usable heat intensive solar thermal storage device other than rock storage and water tank. Four different sizes of soup cans were stacked in a chamber in three different arrangements-vertical, horizontal, and random. Air is used as transfer medium for charging and discharge modes at three different mass flow rates and inlet air temperature respectively. These results are analyzed and compared, which show that a vertical stacking and medium size cans with Length/Diameter (L/D) ratio close to one have better average characteristics of heat transfer and pressure drop.

Saha, H.↗

Effect of 0.1 at. pct Zirconium on the cyclic oxidation resistance of beta-NiAl

The effect of 0.1 at. pct Zr on the cyclic oxidation of hipped beta-NiAl was studied. Oxidation testing was performed in static air at 1100-1200 C, using 1-hr exposure cycles for test times up to 3000 hr. The weight change versus time data were modeled with the COSP computer program to analyze and predict cyclic-oxidation behavior. Zr additions significantly change the nature of the scale-spalling process during cooling, so that the oxide spalls near the oxide-air interface at a relatively low depth within the scale. Without Zr, the predominantly alpha-Al2O3 scale tends to spall randomly to bare metal at relatively high effective-scale-loss rates, particularly at 1150 C and 1200 C. This leads to higher rates of Al consumption for the Zr-free aluminide and much earlier depletion of Al, leading to eventual breakaway (i.e., failure).

Barrett, Charles A.↗

NASA’s Ground-Based Microgravity Simulation Facility

Since opportunities to conduct experiments in space are scarce, various microgravity simulators and analogs have been widely used in space biology ground studies. Even though microgravity simulators do not produce all of the biological effects observed in the true microgravity environment, they provide alternative test platforms that are effective, affordable, and readily available to facilitate microgravity research. The Microgravity Simulation Support Facility (MSSF) at the National Aeronautics and Space Administration (NASA) John F. Kennedy Space Center (KSC) has been established for conducting short duration experiments, typically less than 1 month, utilizing a variety of microgravity simulation devices for research at different gravity levels. The simulators include, but are not limited to, 2D Clinostats, 3D Clinostats, Random Positioning Machines, and Rotating Wall Vessels. In this presentation, we will provide an overview of current MSSF capabilities, research conducted in MSSF, new technology developments, customized sample holder designs, and the physical characteristics of these microgravity simulators.

Ye Zhang↗

NASA's Ground-Based Microgravity Simulation Facility

Since opportunities to conduct experiments in space are scarce, various microgravity simulators and analogs have been widely used in space biology ground studies. Even though microgravity simulators do not produce all of the biological effects observed in the true microgravity environment, they provide alternative test platforms that are effective, affordable, and readily available to facilitate microgravity research. The Microgravity Simulation Support Facility (MSSF) at the National Aeronautics and Space Administration (NASA) John F. Kennedy Space Center (KSC) has been established for conducting short duration experiments, typically less than 1 month, utilizing a variety of microgravity simulation devices for research at different gravity levels. The simulators include, but are not limited to, 2D Clinostats, 3D Clinostats, Random Positioning Machines, and Rotating Wall Vessels. In this chapter, we will discuss current MSSF capabilities, development concepts, customized sample holder designs, and the physical characteristics of these microgravity simulators.

Ye Zhang↗

General purpose research rotor

An analytical study, under a NASA contract, is performed on an advanced flight research rotor (four-bladed, 54 ft in diameter, with bearingless rotor retention characteristics) to determine the sensitivity of total rotor characteristics such as vibratory hub loads, rotor horsepower, and blade loads, to parametric variability of the rotor configuration. The sensitivity of the rotor to various combinations of blade planform taper, percent of blade span that is tapered, tip sweep angle, built-in-twist, and torsional frequency is determined for specific configurations by randomly selecting combinations of these parameters. Characteristics of other intermediate rotor configurations are determined by a regression analysis. The results show that a wide range of rotor total performance characteristics can be obtained for a rotor trimmed to the same flight conditions. The regression equations predict total performance of the rotor very well and appear to be a useful analytical tool for rotor design optimization. Figures showing the results of the various tests are given along with a table of the regression coefficients.

Jones, R.↗

Determination of highly accurate orbits for altimeter satellites over limited geographic areas

Accurate orbits are necessary for altimeter satellites for operational computation of sea surface heights and for the determination of any bias in the altimeter measurement. These satellites require high accuracy throughout the orbit, in general a difficult task due to gravity model, solar radiation pressure, and atmospheric drag effects. Extensive analysis has reduced such errors for Seasat only to the 50 cm level. For calibration purposes the use of such an orbit would require a very large number of tracks to reduce the error to the sub-10 cm level even if all passes had only random errors. Since altimeter calibration orbits require high accuracy only over a limited geographical area, the use of a ranging station, such as a laser tracker in the calibration area can provide the required accuracy. The Bermuda laser provided such orbits for Seasat, with satellite-station height accuracy estimated to be at the sub-3 cm level. Because the station height is accurately known, such orbits can also be used to test global orbit accuracies.

Kolenkiewicz, R.↗

Comparison of Interstitial Fluid pH, PCO2, PO2 with Venous Blood Values During Repetitive Handgrip Exercise

We evaluated the use of a small, fiber optic sensor to measure pH, PCO2 and PO2 from forearm muscle interstitial fluid (IF) during handgrip dynamometry. PURPOSE: Compare pH, PCO2 and PO2 values obtained from venous blood with those from the IF of the flexor digitorum superficialis (FDS) during three levels of exercise intensity. METHODS: Six subjects (5M/1F), average age 29+/-5 yrs, participated in the study. A venous catheter was placed in the retrograde direction in the antecubital space and a fiber optic sensor (Paratrend, Diametrics Medical, Inc.) was placed through a 22 G catheter into the FDS muscle under ultrasound guidance. After a 45 min rest period, subjects performed three 5-min bouts of repetitive handgrip exercise (2s contraction/1 s relaxation) at attempted levels of 15%, 30% and 45% of maximal voluntary contraction. The order of the exercise bouts was random with the second and third bouts started after blood lactate had returned to baseline. Venous blood was sampled every minute during exercise and analyzed with an I-Stat CG-4+ cartridge, while IF fiber optic sensor measurements were obtained every 2 s. Change from pre-exercise baseline to end of exercise was computed for pH, PCO2 and PO2. Blood and IF values were compared with a paired t-test. RESULTS: Baseline values for pH, PCO2 and PO2 were 7.37+/-0.02, 46+/-4 mm Hg, and 36+/-6 mm Hg respectively in blood and 7.39+/-0.02, 44+/-6 mm Hg, and 35+/-14 mm Hg in IF. Average changes over all exercise levels are noted in the Table below. For each parameter the exercise-induced change was at least twice as great in IF as in blood. In blood and IF, pH and PCO2 increases were directly related to exercise intensity. Change in venous PO2 was unrelated to exercise intensity, while IF PO2 decreased with increases in exercise intensity. CONCLUSIONS: Measurement of IF pH, PCO2 and PO2 is more sensitive to exercise intensity than measurement of the same parameters in venous blood and provides continuous assessment during and after exercise.

Hagan, Ronald Donald↗

Vibration simulator studies for the development of passenger ride comfort criteria

A test program to determine the total discomfort associated with vehicle vibration is described. The program utilizes a three-degree-of-freedom vibration simulator to determine the effects of multifrequency and multiaxis vibration inputs. The approach to multifrequency vibration includes a separate consideration of the discomfort associated with each frequency component or band of the total spectrum and a subsequent empirical weighting of the discomfort components of these frequency bands when in various random combinations. The results are in the form of equal discomfort curves that specify the discomfort associated with discrete frequencies between 1 and 30 Hz and different acceleration levels. These results provide detailed information of the human discomfort response to increases in acceleration level for each frequency investigated. More importantly, the results provide a method for adding the discomfort associated with separate frequencies to give a total typification of the discomfort of a random spectrum of vibration.

Dempsey, T. K.↗

Analysis of dual control vibration testing

Analysis of dual control vibration testing is conducted using a two-degree-of-freedom system to represent the interaction between a vibration mode of a test item and a mode of a mounting structure. The results indicate that exact dual control based on specification of the source free acceleration and blocked force is strictly valid only if phase is taken into account. However, extremal dual control without phase alleviates overtesting without risk of undertesting, when the limit acceleration and force specifications are chosen to envelope the coupled system results. Several approaches to deriving appropriate force specifications are explored. Random vibration parametric results from the literature are used to estimate the limit force between coupled oscillators with different source and load masses.

Scharton, Terry D.↗

A two dimensional interface element for coupling of independently modeled three dimensional finite element meshes and extensions to dynamic and non-linear regimes

The work reported here pertains only to the first year of research for a three year proposal period. As a prelude to this two dimensional interface element, the one dimensional element was tested and errors were discovered in the code for built-up structures and curved interfaces. These errors were corrected and the benchmark Boeing composite crown panel was analyzed successfully. A study of various splines led to the conclusion that cubic B-splines best suit this interface element application. A least squares approach combined with cubic B-splines was constructed to make a smooth function from the noisy data obtained with random error in the coordinate data points of the Boeing crown panel analysis. Preliminary investigations for the formulation of discontinuous 2-D shell and 3-D solid elements were conducted.

Aminpour, Mohammad↗

Idealized textile composites for experimental/analytical correlation

Textile composites are fiber reinforced materials produced by weaving, braiding, knitting, or stitching. These materials offer possible reductions in manufacturing costs compared to conventional laminated composites. Thus, they are attractive candidate materials for aircraft structures. To date, numerous experimental studies have been performed to characterize the mechanical performance of specific textile architectures. Since many materials and architectures are of interest, there is a need for analytical models to predict the mechanical properties of a specific textile composite material. Models of varying sophistication have been proposed based on mechanics of materials, classical laminated plate theory, and the finite element method. These modeling approaches assume an idealized textile architecture and generally consider a single unit cell. Due to randomness of the textile architectures produced using conventional processing techniques, experimental data obtained has been of limited use for verifying the accuracy of these analytical approaches. This research is focused on fabricating woven textile composites with highly aligned and accurately placed fiber tows that closely represent the idealized architectures assumed in analytical models. These idealized textile composites have been fabricated with three types of layer nesting configurations: stacked, diagonal, and split-span. Compression testing results have identified strength variations as a function of nesting. Moire interferometry experiments are being used to determine localized deformations for detailed correlation with model predictions.

Adams, Daniel O.↗

Pseudo-Random Modulation of a Laser Diode for Generating Ultrasonic Longitudinal Waves

Laser generated ultrasound systems have historically been more complicated and expensive than conventional piezoelectric based systems, and this fact has relegated the acceptance of laser based systems to niche applications for which piezoelectric based systems are less suitable. Lowering system costs, while improving throughput, increasing ultrasound signal levels, and improving signal-to-noise are goals which will help increase the general acceptance of laser based ultrasound. One current limitation with conventional laser generated ultrasound is a material s damage threshold limit. Increasing the optical power to generate more signal eventually damages the material being tested due to rapid, high heating. Generation limitations for laser based ultrasound suggests the use of pulse modulation techniques as an alternate generation method. Pulse modulation techniques can spread the laser energy over time or space, thus reducing laser power densities and minimizing damage. Previous experiments by various organizations using spatial or temporal pulse modulation have been shown to generate detectable surface, plate, and bulk ultrasonic waves with narrow frequency bandwidths . Using narrow frequency bandwidths improved signal detectability, but required the use of expensive and powerful lasers and opto-electronic systems. The use of a laser diode to generate ultrasound is attractive because of its low cost, small size, light weight, simple optics and modulation capability. The use of pulse compression techniques should allow certain types of laser diodes to produce usable ultrasonic signals. The method also does not need to be limited to narrow frequency bandwidths. The method demonstrated here uses a low power laser diode (approximately 150 mW) that is modulated by controlling the diode s drive current and the resulting signal is recovered by cross correlation. A potential application for this system which is briefly demonstrated is in detecting signals in thick composite materials where attenuation is high and signal amplitude and bandwidth are at a premium.

Madaras, Eric I.↗

Application of a Planar Doppler Velocimetry System to a High Reynolds Number Compressible Jet

A Planar Doppler Velocimetry (PDV) system has been constructed and used to investigate the instantaneous turbulent velocity structure of a round high-speed compressible air jet with a low-speed co-flow. The exit condition was Mach=0.85 at ambient pressure, yielding a Reynolds number of about 650,000 on diameter. The PDV system was installed at NASA Langley Research Center in the Small Anechoic Jet Facility (SAJF), a chamber in which both the acoustic and aerodynamic properties of jets can be studied. For this test, the goal was to gather data which can be used to relate the turbulence structure of the jet to the levels and character of the acoustic noise produced by the jet. The current PDV system can acquire single-velocity-component, single-shot, planar images (15ns exposures) at 30 Hz. For this paper, the primary data set consists of 240 frames of velocity data acquired with both the jet and the low-speed co-flow seeded with light-scattering articles. Thus, velocities could be measured everywhere in the jet shear layer, both in the jet fluid and in the entrained co-flow. Some data were also taken with only the jet flow seeded. These provided mixing concentration images along with the reduced velocity fields. Other images were taken with only the co-flow seeded. These produced unique quantitative images of high speed entrainment. Optical "laser speckle" noise is the largest source of random noise in pulsed PDV systems. Components for the PDV imaging system were specifically selected to minimize speckle noise. To reduce systematic velocity errors due to laser drift, a frequency monitoring reference leg with a temperature-tuned reference iodine cell, was employed. In the course of this study, a novel flow seeder was developed. It enabled continuously variable seeding of the flow with particles of Sheared Pyrogenic Amorphous Hydrophobic Silica (SPAHS). The seeder comprised a dry fluidized bed hopper and a supersonic nozzle "pickup." Shearing action in the pickup dispersed the seed material in an exceptionally fine cloud (approximately 0.3 micron). These particles followed the flow well, did not clump or cake on screens or model surfaces, and were not susceptible to evaporation. Because of the refractory nature of the particles, SPAHS seeding should also be applicable to anticipated future testing at high temperatures.

Smith, Michael W.↗

Accuracy of RGD approximation for computing light scattering properties of diffusing and motile bacteria

The study tests the accuracy of the Rayleigh-Gans-Debye (RGD) approximation against a rigorous scattering theory calculation for a simplified model of E. coli (about 1 micron in size) - a solid spheroid. A general procedure is formulated whereby the scattered field amplitude correlation function, for both polarized and depolarized contributions, can be computed for a collection of particles. An explicit formula is presented for the scattered intensity, both polarized and depolarized, for a collection of randomly diffusing or moving particles. Two specific cases for the intermediate scattering functions are considered: diffusing particles and freely moving particles with a Maxwellian speed distribution. The formalism is applied to microorganisms suspended in a liquid medium. Sensitivity studies revealed that for values of the relative index of refraction greater than 1.03, RGD could be in serious error in computing the intensity as well as correlation functions.

Kottarchyk, M.↗

Screening actuator locations for static shape control

Correction of shape distortion due to zero-mean normally distributed errors in structural sizes which are random variables is examined. A bound on the maximum improvement in the expected value of the root-mean-square shape error is obtained. The shape correction associated with the optimal actuators is also characterized. An actuator effectiveness index is developed and shown to be helpful in screening actuator locations in the structure. The results are specialized to a simple form for truss structures composed of nominally identical members. The bound and effectiveness index are tested on a 55-m radiometer antenna truss structure. It is found that previously obtained results for optimum actuators had a performance close to the bound obtained here. Furthermore, the actuators associated with the optimum design are shown to have high effectiveness indices. Since only a small fraction of truss elements tend to have high effectiveness indices, the proposed screening procedure can greatly reduce the number of truss members that need to be considered as actuator sites.

Haftka, Raphael T.↗

The NASA Langley Mars Tumbleweed Rover Prototype

Mars Tumbleweed is a concept for an autonomous rover that would achieve mobility through use of the natural winds on Mars. The wind-blown nature of this vehicle make it an ideal platform for conducting random surveys of the surface, scouting for signs of past or present life as well as examining the potential habitability of sites for future human exploration. NASA Langley Research Center (LaRC) has been studying the dynamics, aerodynamics, and mission concepts of Tumbleweed rovers and has recently developed a prototype Mars Tumbleweed Rover for demonstrating mission concepts and science measurement techniques. This paper will provide an overview of the prototype design, instrumentation to be accommodated, preliminary test results, and plans for future development and testing of the vehicle.

Antol, Jeffrey↗

Reliability analysis of the F-8 digital fly-by-wire system

The F-8 Digital Fly-by-Wire (DFBW) flight test program intended to provide the technology for advanced control systems, giving aircraft enhanced performance and operational capability is addressed. A detailed analysis of the experimental system was performed to estimated the probabilities of two significant safety critical events: (1) loss of primary flight control function, causing reversion to the analog bypass system; and (2) loss of the aircraft due to failure of the electronic flight control system. The analysis covers appraisal of risks due to random equipment failure, generic faults in design of the system or its software, and induced failure due to external events. A unique diagrammatic technique was developed which details the combinatorial reliability equations for the entire system, promotes understanding of system failure characteristics, and identifies the most likely failure modes. The technique provides a systematic method of applying basic probability equations and is augmented by a computer program written in a modular fashion that duplicates the structure of these equations.

Brock, L. D.↗

Evaluation of Data Retention Characteristics for Ferroelectric Random Access Memories (FRAMs)

Data retention and fatigue characteristics of 64 Kb lead zirconate titanate (PZT)-based Ferroelectric Random Access Memories (FRAMs) microcircuits manufactured by Ramtron were examined over temperature range from -85 C to +310 C for ceramic packaged parts and from -85 C to +175 C for plastic parts, during retention periods up to several thousand hours. Intrinsic failures, which were caused by a thermal degradation of the ferroelectric cells, occurred in ceramic parts after tens or hundreds hours of aging at temperatures above 200 C. The activation energy of the retention test failures was 1.05 eV and the extrapolated mean-time-to-failure (MTTF) at room temperature was estimated to be more than 280 years. Multiple write-read cycling (up to 3x10(exp 7)) during the fatigue testing of plastic and ceramic parts did not result in any parametric or functional failures. However, operational currents linearly decreased with the logarithm of number of cycles thus indicating fatigue process in PZT films. Plastic parts, that had more recent date code as compared to ceramic parts, appeared to be using die with improved process technology and showed significantly smaller changes in operational currents and data access times.

Sharma, Ashok K.↗