Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Plasma shape and position control development for NSTX-U using the GSEvolve plasma simulator

NSTX-U discharges have been reproduced using the GSEvolve plasma simulator in order to improve their control and reduce oscillations during the plasma current (Ip) ramp-up phase, and with the ultimate goal of enabling reliable H-mode access with a double-null shape at high elongation, low internal inductance, and high plasma performance. The control objective is to eliminate undesired oscillations in the plasma shape and vertical position that start when the plasma diverts during the Ip ramp-up phase, and that happened recurrently during the first NSTX-U experimental campaign. Model-based control solutions have been developed, including alternative H-mode access recipes and a Multi-Input Multi-Output (MIMO) decoupling controller. These solutions have demonstrated their capability to reduce or eliminate the aforementioned oscillations in GSEvolve simulations, enabling reproducible H-mode access. The results of this work aim to inform NSTX-U experimental operations on potential control developments to maximize its scientific output, and highlight the powerful capabilities of high-fidelity control-simulation frameworks like GSEvolve.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Feedback and Oscillations: Constructing Feedback Systems for Root Cause Analysis of Oscillations in Power Grids

Dynamic phenomena linked to inverter-based resources (IBRs) have gained global attention. Several IBR-induced dynamics have caused bulk power system-connected wind or solar power plants to trip, and some have even led to widespread outages. In addition, many oscillations have been observed involving IBR power plants. In 2023, the IEEE Power & Energy Society (PES) IBR Subsynchronous Oscillations (SSO) task force published a journal article, “Real-World Subsynchronous Oscillation Events in Power Grids With High Penetrations of Inverter-Based Resources,” in which 19 IBR oscillation events were examined for their causation. Earlier in 2020, another PES task force article, “Definition and Classification of Power System Stability-Revisited & Extended,” authored by prominent academics, introduced converter-driven stability as a new category of stability. The international power grid industry community also took action by publishing the CIGRE Green Book, Power System Dynamic Modelling and Analysis in Evolving Networks (led by Babak Badrzadeh and Zia Emin) in 2024. In August 2024, the Energy Systems Integration Group (ESIG) released a practical guide led by Nick Miller, “Diagnosis and Mitigation of Observed Oscillations in IBR-Dominant Power System: A Practical Guide.” The goal of the guide is to assist practicing engineers in making initial judgments and conducting detailed analyses about oscillations. Finally, when addressing the classification of stability and oscillations, the guide emphasizes a causality-based taxonomy for grouping, such as voltage control-induced oscillations, synchronization-induced oscillations, and frequency or active power control-induced oscillations.

Fan, Lingling [Univ. of South Florida, Tampa, FL (↗

Submodule-Level Decentralized Control for Cascaded Quadruple Active Bridge-Based Medium-Voltage Converters: Preprint

High-power, low-voltage DC (LVDC) loads, such as AI data centers, electric vehicle fast-charging hubs, and hydrogen electrolyzers, are accelerating the deployment of solid-state transformers (SSTs) that directly interface medium-voltage AC (MVAC) to LVDC, streamlining power delivery. This paper proposes a submodule-level decentralized control strategy for an SST comprising a cascaded H-bridge (CHB) active rectifier on the MVAC side and per-module quadruple-active-bridge (QAB) converters on the LVDC side with local controllers. The proposed strategy eliminates the need for high-fidelity, real-time cross-isolation communication by synchronizing all active bridges to a common heartbeat signal and enabling the primary- and secondary-side controllers to generate independent local control signals (phase shifts). The resultant phase shifts naturally govern average and double-line frequency power transfer between active bridges, enabling each side to meet its control objectives using only local measurements. Detailed controller design considerations are presented based on a stability analysis. Comprehensive electromagnetic-transient simulations demonstrate tight DC-link voltage regulation, high-quality grid currents, and robust operation under load transients and grid disturbances, without real-time communication among the submodule controllers. These results indicate that the proposed scheme can significantly enhance the reliability, scalability, and flexibility of cascaded bridge-based medium-voltage converters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Control methods for mitigating flow oscillations in a supercritical CO 2 recompression closed Brayton cycle

A dynamic model of a 10 MWe supercritical CO 2 (sCO 2 ) recompression closed Brayton power generation cycle is used to investigate control methods for mitigating oscillations in flow conditions and power demand load, especially as the load ramp rate is increased and the load setpoint is more closely tracked. The focus is on control of the main compressor inlet temperature (MCIT) since oscillations are prompted by the strong nonlinearities in sCO 2 fluid properties near the critical point and by changes in system inventory for efficient load management. In this study, the oscillatory behavior during load ramping is first shown and then two potential control solutions for substantially reducing oscillations are given: 1) the use of the main compressor inlet guide vanes (IGV) and 2) bypassing a portion of the sCO 2 around the cooler to maintain the MCIT. These control methods reduce the effect of cycle feedback from interactions between the MCIT and load. When implementing either control method, a load setpoint ramp of 7.5%/min was maintainable while achieving closer load setpoint tracking with limited oscillations. Finally, the impact of sensor noise on the control was examined since derivative action was used in the IGV and cooler sCO 2 bypass control. Finally, while some effect was evident, signal noise was not problematic to the control.

24 POWER TRANSMISSION AND DISTRIBUTION↗

sCO2 Primary Power Large-Scale Pilot Plant FEED Summary

Echogen Power Systems and its project partners the Electric Power Research Institute, CDM Smith, Riley Power Inc. (a Babcock Power Inc. company), and the University of Missouri completed the Front-End Engineering Design (FEED) study of a nominal 10 MWe supercritical carbon dioxide (sCO2) large-scale pilot plant based on Recompression Brayton Cycle (RCBC) architecture. The FEED study was completed under Phase II of the U.S. Department of Energy Fossil Fuel Large-Scale Pilots program. The FEED study scope included the preliminary design of the combustion and environmental control systems, the primary heater, the sCO2 power cycle and its associated turbomachinery, and the balance of plant equipment to determine accurate cost and schedule requirements for fabrication and installation of the system at the University of Missouri’s Combined Cooling, Heat, and Power Plant, located in Columbia, Missouri. The RCBC sCO2 cycle presents superior thermodynamic efficiency compared to steam-Rankine cycles and is adaptable to a broad range of heat sources. The risk aversion of the power generation industry requires a successful large-scale pilot plant demonstration to enable financing and deployment of commercial-scale plants. Therefore, successful construction and demonstration of a 10 MWe RCBC sCO2 power plant would empower a transformational step forward for the efficiency of the next generation of utility power plants. This paper provides details on the primary heater, environmental control systems, and sCO2 power cycle design and performance.

01 COAL, LIGNITE, AND PEAT↗

Performance Evaluation of Distributed Energy Resources Management System via Advanced Hardware-in-the-Loop Simulation: Preprint

This paper presents an advanced hardware-in-the-loop (HIL) platform to evaluate the performance of voltage regulation coordinated across advanced distribution management systems (ADMS), distributed energy management system (DERMS), and DERs. The HIL platform provides realistic laboratory testing, including accurate modeling of the real-world distribution system from a utility partner, real controller (ADMS and DERMs) and power (DERs) hardware, and standard communications protocols. The test results show proper functionalities of the integrated platform and performance of the peak load management of coordinated control systems. Based on the laboratory testing, the utility can set up the same grid automation system to manage DERs to achieve system-level control and operation objectives (e.g., peak load management), thus derisking potential issues (e.g., instability) for field deployment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Bioresorbable Primary Battery Anodes Built on Core–Double-Shell Zinc Microparticle Networks

Bioresorbable implantable electronics require power sources that are also bioresorbable with controllable electrical output and lifetime. In this paper, we report a bioresorbable zinc primary battery anode filament based on a zinc microparticle (MP) network coated with chitosan and Al 2 O 3 double shells. When discharged in 0.9% NaCl saline, a Zn MP filament with a 0.17 × 2 mm 2 cross-sectional area exhibited a stable voltage output of 0.55 V at a current of 0.01 mA. Covered by chitosan and Al 2 O 3 double shells, the zinc MP filament exhibited a directional dissolution behavior with a tunable lifetime approximately linear to its length. A stable 200 h discharging time was achieved with a 15 mm Zn MP filament. The maximum output power was found to be 12 μW at 0.03 mA for one filament. The linearity relationship between the current output and the filament cross-sectional area suggested a facile strategy to raise the power output at constant discharging voltage. The filaments could also be connected in series and in parallel to boost its overall voltage and current output, demonstrating their excellent integration capability. Furthermore, this work presents a promising pathway toward bioresorbable transient batteries with controllable lifetime and power output, demonstrating a great potential for powering transient implantable biomedical devices.

25 ENERGY STORAGE↗

Predictive Direct DC-Link Control for 7.2 kV Three-Port Low-Inertia Solid-State Transformer With Active Power Decoupling

Promising for applications including renewable energy and electric vehicle fast charging, a medium-voltage (MV) solid-state transformer (SST) typically has multiple modules series stacked, which requires the modules to be single phase. One critical issue of the single-phase SST is the double-line-frequency power ripple. Traditionally, large passives are used to buffer the ripple, resulting in significantly increased volume and cost. This article for the first time proposes active power decoupling (APD) for the SST and a predictive direct DC-link control method, using a current-source single-stage SST as an example. An electrolytic capacitor-less buffer port is used to absorb the ripple, which tolerates up to a 30% voltage ripple for small capacitance. The APD SST control is challenging. First, the current-source SST realizes isolation, DC link, and multiport in a single stage. Second, different from conventional SSTs or APD converters, the low-inertia DC link in this SST has a 40% switching ripple, which is difficult to stabilize. To address the control challenge, a direct DC-link control architecture and a predictive control method are proposed. Simulation and experimental results verify the proposed control method on an MV SiC modular soft-switching solid-state transformer (M-S4T) prototype. Here, the proposed APD reduces the SST volume by 53.8%. Importantly, the proposed concept is not limited to the M-S4T but is generic to other SSTs or APD converters.

14 SOLAR ENERGY↗

Isotope dependence of the type I ELMy H-mode pedestal in JET-ILW hydrogen and deuterium plasmas

The pedestal structure, edge transport and linear MHD stability have been analyzed in a series of JET with the ITER-like wall hydrogen (H) and deuterium (D) type I ELMy H-mode plasmas. The pedestal pressure is typically higher in D than in H at the same input power and gas rate, with the difference mainly due to lower density in H than in D (Maggi et al (JET Contributors) 2018 Plasma Phys. Control. Fusion 60 014045). A power balance analysis of the pedestal has shown that higher inter-ELM separatrix loss power is required in H than in D to maintain a similar pedestal top pressure. This is qualitatively consistent with a set of interpretative EDGE2D-EIRENE simulations for H and D plasmas, showing that higher edge particle and heat transport coefficients are needed in H than in D to match the experimental profiles. It has also been concluded that the difference in neutral penetration between H and D leads only to minor changes in the upstream density profiles and with trends opposite to experimental observations. This implies that neutral penetration has a minor role in setting the difference between H and D pedestals, but higher ELM and/or inter-ELM transport are likely to be the main players. The interpretative EDGE2D-EIRENE simulations, with simultaneous upstream and outer divertor target profile constraints, have indicated higher separatrix electron temperature in H than in D for a pair of discharges at low fueling gas rate and similar stored energy (which required higher input power in H than in D at the same gas rate). The isotope dependence of linear MHD pedestal stability has been found to be small, but if a higher separatrix temperature is considered in H than in D, this could lead to destabilization of peeling-ballooning modes and shrinking of the stability boundary, qualitatively consistent with the reduced pedestal confinement in H.

08 HYDROGEN↗

Differential Power Processing for Ultra-Efficient Data Storage

Here this paper presents the hardware, software, and power codesign of an ultra-efficient data storage server with differential power processing (DPP). DPP can reduce the power conversion stress, improve the efficiency, and enhance the functionality of modular power electronics systems. The power inputs of a large number of hard disk drives (HDDs) were connected in series and supported by a multiport ac-coupled differential power processing (MAC-DPP) converter through a multiwinding transformer. Methods for controlling the multi-input multi-output power flow in the multiwinding transformer while avoiding core saturation were investigated. A ten-port MAC-DPP prototype with 700-W/in 3 power density was built to support a 450-W HDD storage system with ten series-stacked voltage domains. The prototype was tested on a 50-HDD server testbench, and the overall system loss is below 1 W (99.77% system efficiency). The server was able to maintain high-speed reading and writing operation of all 50 HDDs against the worst hot-swapping scenarios. A variety of hardware/software configurations and many cloud storage techniques were tested on the fully functioning server. Experimental results show that the energy efficiency of large-scale information systems (CPU/GPU clusters, memory banks, HDD arrays, etc.) can be greatly improved by software, hardware, and power codesign.

42 ENGINEERING↗

Assessment of the burning-plasma operational space in ITER by using a control-oriented core-SOL-divertor model

In future tokamaks, the control of burning plasmas will require careful regulation of the plasma density and temperature. Along with the design of effective burn-control systems, understanding how the fusion power varies in the density-temperature space is vital for the operation of fusion power plants. Here in this work, the steady-state operational space of ITER is studied using a control-oriented core-plasma model coupled to a two-point model of the scrape-off-layer (SOL) and divertor regions. The two models are coupled through the exchange of input-output parameters. The deuterium and tritium recycling from the wall are output parameters of the SOL-divertor model that are used as input parameters in the core-plasma density balance. Furthermore, the separatrix temperature, which is an output parameter of the SOL-divertor model, is incorporated into the radial core-plasma temperature profiles. Therefore, the temperature-dependent power balance of the plasma core is intimately linked to the SOL-divertor model. Both the power entering the SOL from the core, as determined by the core-plasma power balance, and the separatrix density, as dictated by the core-plasma density balance, are input parameters to the SOL-divertor model. They are control knobs in the SOL-divertor model that can be regulated using the core-plasma actuators: auxiliary power and pellet injection. There are various operational limitations, such as the saturation of the aforementioned actuators, that will prevent ITER from accessing certain high-fusion plasma regimes. The achievable tritium concentration in the fueling lines and the maximum sustainable heat load on the divertor will impose further restrictions. By accounting for these limitations, the ITER operational space is computed based on the coupled core-SOL-divertor model and visualized using Plasma Operation Contour (POPCON) plots that map performance metrics, such as the fusion to auxiliary power ratio, over the density-temperature space. Comparisons are drawn between plasmas with different recycling, confinement, and SOL-divertor conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Droop Control-Based Dispatch of an Islanded Microgrid with Multiple Grid-Forming Sources

Before rotating, fossil fuel-based, synchronous generators (SGs) are phased out, in line with renewable generation goals, grid-forming (GFM) inverters are expected to parallel SGs. Primary droop control allows GFM inverters to share power without communication; however, it is necessary to dispatch GFM inverters and/or SGs with the desired output power for better energy management (e.g., one GFM inverter needs to charge the battery due to a low state of charge). Therefore, this paper develops an analytic approach to dispatching GFM inverters and SGs with the desired output power by shifting the droop intercept up/down while maintaining the same frequency operating point for improved transient stability. This concept is demonstrated through a pure hardware setup with two off-the-shelf inverters and one diesel generator under an islanded microgrid, and we provide insight on the real-world implementation of the proposed concept.

droop control↗

Droop Control-Based Dispatch of an Islanded Microgrid With Multiple Grid-Forming Sources

Before rotating, fossil fuel-based, synchronous generators (SGs) are phased out, in line with renewable generation goals, grid-forming (GFM) inverters are expected to parallel SGs. Primary droop control allows GFM inverters to share power without communication; however, it is necessary to dispatch GFM inverters and/or SGs with the desired output power for better energy management (e.g., one GFM inverter needs to charge the battery due to a low state of charge). Therefore, this paper develops an analytic approach to dispatching GFM inverters and SGs with the desired output power by shifting the droop intercept up/down while maintaining the same frequency operating point for improved transient stability. This concept is demonstrated through a pure hardware setup with two off-the-shelf inverters and one diesel generator under an islanded microgrid, and we provide insight on the real-world implementation of the proposed concept.

droop control↗

Highlighting the Impact of Yaw Control by Parsing Atmospheric Conditions Based on Total Variation: Preprint

Identification of atmospheric conditions within a multivariate atmospheric dataset is a necessary step in the validation of wind plant control strategies. Most often, operating conditions are characterized in terms of aggregated observations and assume that the atmosphere is 'quasi-steady'. Aggregation of observations without regard to covariance between time series discounts the dynamical nature of the atmosphere and is not sufficiently representative of wind plant operating conditions. Identification and characterization of continuous time periods with atmospheric conditions that have a high value for analysis or simulation sets the stage for more advanced model validation and the development of real-time control and operation strategies. Controlling observational data for statistical stationarity highlights significant enhancements to the power production of waked turbines under wake steering wind plant control. Considering the combined energy ratio of the turbine to which yaw offsets are prescribed as well as the waked turbine show only moderate improvements when filtering for total validation. The same quality control that highlights wake steering also serves to underpin the off-nominal operation of the controlled turbine.

17 WIND ENERGY↗

Data-driven Resilience Characterization of Control Dynamical Systems

In this paper, we define and quantify resiliency of a power network and propose data-driven algorithms for computing the same for the power grid. To do this, we use the Koopman operator framework to lift the controlled dynamical system to an abstract (possibly higher) dimensional space, where the evolution is linear. The linear system representation allows us to relate small time local controllability and observability of a general nonlinear control system to the controllability and observability of the lifted linear system. Finally, we define the resiliency of the underlying power grid in terms of the controllability and observability gramians of the lifted linear system. We illustrate the proposed approach to compute the resiliency metrics on time-series data obtained from a microgrid.

koopman operator, resilience, control↗

3D radiated power analysis of JET SPI discharges using the Emis3D forward modeling tool

Abstract Precise values for radiated energy in tokamak disruption experiments are needed to validate disruption mitigation techniques for burning plasma tokamaks like ITER and SPARC. Control room analysis of radiated power ( P rad ) on JET assumes axisymmetry, since fitting 3D radiation structures with limited bolometry coverage is an under-determined problem. In mitigated disruptions, radiation is toroidally asymmetric and 3D, due to fast-growing 3D MHD modes and localized impurity sources. To address this problem, Emis3D adopts a physics motivated forward modeling (‘guess and check’) approach, comparing experimental bolometry data to synthetic data from user-defined radiation structures. Synthetic structures are observed with the Cherab modeling framework and a best fit chosen using a reduced χ 2 statistic. 2D tomographic inversion models are tested, as well as helical flux tubes and 3D MHD simulated structures from JOREK. Two nominally identical pure neon shattered pellet injection (SPI) mitigated discharges in JET are analyzed. 2D tomographic inversions with added toroidal freedom are the best fits in the thermal quench (TQ) and current quench (CQ). In the pre-TQ, 2D reconstructions are statistically the best fits, but are likely over-optimized and do not capture the 3D radiation structure seen in fast camera images. The next-best pre-TQ fits are helical structures that extend towards the high-field side, consistent with an impurity flow under the magnetic nozzle effect also observed in JOREK simulations. Whole-disruption radiated fractions of 0.98 + 0.03 / − 0.29 and 1.01 + 0.02 / − 0.17 are found, suggesting that the stored energy may have been fully mitigated by each SPI, although mitigation efficiencies well below ITER and SPARC requirements for high energy pulses are still within the large uncertainties. Emis3D is also used to validate JOREK SPI simulations, and confirms improvements in matching experiment from changes to impurity modeling. Time-dependent toroidal peaking factors are calculated and discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Photovoltaic MPPT Charge Controller Real-Time Testbed for Cybersecurity Applications

The increasing deployment of distributed energy resources (DER) over the last decade is a great ally to combat climate change and strengthen the grid during increasingly common extreme weather events. However, DER systems, combined with the ongoing transition to a digital power grid, also pose substantial cybersecurity threats. One of the most common communication protocols used in DER integration is the Distributed Network Protocol 3 (DNP3), which is known to have many security vulnerabilities. Thus, it is essential to investigate cyberattack behaviors and mitigation on power systems using DNP3. In this paper, we designed and implemented a cybersecurity testbed for a simulated photovoltaic (PV) maximum power point tracking (MPPT) charge controller. Our testbed uses an MPPT charge controller simulated on a Typhoon HIL602+ real-time simulator with a real DNP3 communication connection over TCP/IP, allowing for safe and efficient monitoring and manipulation of data traffic between the simulated hardware and supervisory control and data acquisition (SCADA) systems.

14 SOLAR ENERGY↗