Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pixel detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Performance of a Modular Ton-Scale Pixel-Readout Liquid Argon Time Projection Chamber

The Module-0 Demonstrator is a single-phase 600 kg liquid argon time projection chamber operated as a prototype for the DUNE liquid argon near detector. Based on the ArgonCube design concept, Module-0 features a novel 80k-channel pixelated charge readout and advanced high-coverage photon detection system. In this paper, we present an analysis of an eight-day data set consisting of 25 million cosmic ray events collected in the spring of 2021. We use this sample to demonstrate the imaging performance of the charge and light readout systems as well as the signal correlations between the two. We also report argon purity and detector uniformity measurements and provide comparisons to detector simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Centroid position measurements and subpixel sensitivity variations with the MAMA detector

Initial measurements of the position sensitivity of a visible-light multianode microchannel array detector show that centroid calculations for image spots are accurate to better than 0.04 pixels even with sources that are essentially delta functions at the photocathode.Subpixel sensitivity variations of 10-15 percent are typically found for pixels in the array. Variations as large as 30 percent are possible in the worst conditions. These variations limit the photometric accuracy of the detector when very small scale features are observed. The photometric accuracy and the position sensitivity of the detector appear to be limited by cross-coupling effects within the anode array. Initial measurements with more recent designs of the detector show that most or all of this cross-coupling has been eliminated.

Morgan, Jeffrey S.↗

Optical Characterization of OMT-Coupled TES Bolometers for LiteBIRD

Feedhorn- and orthomode transducer- (OMT) coupled transition edge sensor (TES) bolometers have been designed and micro-fabricated to meet the optical specifications of the LiteBIRD high frequency telescope (HFT) focal plane. Here, we discuss the design and optical characterization of two LiteBIRD HFT detector types: dual-polarization, dual-frequency-band pixels with 195/280 GHz and 235/337 GHz band centers. Results show well-matched passbands between orthogonal polarization channels and frequency centers within 3% of the design values. The optical efficiency of each frequency channel is conservatively reported to be within the range 0.64–0.72, determined from the response to a cryogenic, temperature-controlled thermal source. These values are in good agreement with expectations and either exceed or are within 10% of the values used in the LiteBIRD sensitivity forecast. Lastly, we report a measurement of loss in Nb/SiN x /Nb microstrip at 100 mK and over the frequency range 200–350 GHz, which is comparable to values previously reported in the literature.

47 OTHER INSTRUMENTATION↗

Understanding neutrinos with accelerator beams and liquid argon time-projection chambers: ICARUS and DUNE

A global program of experiments has worked towards characterizing neutrino oscillation over the past few decades. However, important parameters remain to be measured, and mysteries remain to be elucidated. Current and upcoming experiments are targeting the open questions and probing the consistency of the neutrino oscillation paradigm. Likewise, the liquid argon (LAr) time-projection chamber (TPC) has emerged as a sensitive particle detection technology for neutrino experiments. A current generation of LAr TPC detectors are being used to study neutrinos while also gaining important experience in operating and analyzing with this technology. SBND, MicroBooNE, and ICARUS have collected or are collecting data from beams at Fermilab (near Chicago) to explore the possibility of a sterile neutrino and/or other beyond Standard Model (BSM) physics. SBND and ICARUS will be used to conduct a two-detector analysis as part of the Short Baseline Neutrino (SBN) Program. Additionally, these detectors are enabling important neutrino interaction studies necessary to prepare for the next generation of oscillation experiments. One such oscillation experiment that will come online over the next years is the Deep Underground Neutrino Experiment (DUNE), which will install multiple 10 kiloton LAr TPCs underground in South Dakota (south of Saskatchewan) to conduct oscillation measurements with neutrinos originating in a beamline at Fermilab. A detector complex will be installed at Fermilab as well, to study the beam before the expected flavour oscillations. This “near detector” will also employ a LAr TPC, with a segmented and pixel-based design, as well as other technologies to constrain uncertainties in the oscillation measurement by characterizing the beam and neutrino interactions. This talk will discuss the ICARUS and DUNE experiments, the LAr TPC detector technology, and the efforts to realize and leverage these experiments to better understand the properties of neutrinos.

Howard, Bruce L. [Fermilab]↗

Multi-anode microchannel arrays - New detectors for imaging and spectroscopy in space

Consideration is given to the construction and operation of multi-anode microchannel array detector systems having formats as large as 256 x 1024 pixels. Such arrays are being developed for imaging and spectroscopy at soft X-ray, ultraviolet and visible wavelengths from balloons, sounding rockets and space probes. Both discrete-anode and coincidence-anode arrays are described. Two types of photocathode structures are evaluated: an opaque photocathode deposited directly on the curved-channel MCP and an activated cathode deposited on a proximity-focused mesh. Future work will include sensitivity optimization in the different wavelength regions and the development of detector tubes with semitransparent proximity-focused photocathodes.

Timothy, J. G.↗

Highly multiplexible thermal kinetic inductance detectors for x-ray imaging spectroscopy

For X-ray imaging spectroscopy, high spatial resolution over a large field of view is often as important as high energy resolution, but current X-ray detectors do not provide both in the same device. Thermal Kinetic Inductance Detectors (TKIDs) are being developed as they offer a feasible way to combine the energy resolution of transition edge sensors with pixel counts approaching CCDs and thus promise significant improvements for many X-ray spectroscopy applications. TKIDs are a variation of Microwave Kinetic Inductance Detectors (MKIDs) and share their multiplexibility: working MKID arrays with 2024 pixels have recently been demonstrated and much bigger arrays are under development. In this work, we present a TKID prototype, which is able to achieve an energy resolution of 75 eV at 5.9 keV, even though its general design still has to be optimized. We further describe TKID fabrication, characterization, multiplexing, and working principle and demonstrate the necessity of a data fitting algorithm in order to extract photon energies. With further design optimizations, we expect to be able to improve our TKID energy resolution to less than 10 eV at 5.9 keV.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cross-correlation search for a hot spot of gravitational waves

The cross-correlation search has been previously applied to map the gravitational wave (GW) stochastic background in the sky and also to target GW from rotating neutron stars/pulsars. Here we investigate how the cross-correlation method can be used to target a small region in the sky spanning at most a few pixels, where a pixel in the sky is determined by the diffraction limit which depends on the (i) baseline joining a pair of detectors and (ii) detector bandwidth. Here as one of the promising targets, we consider the Virgo cluster--a ''hot spot'' spanning few pixels--which could contain, as estimates suggest {approx}10{sup 11} neutron stars, of which a small fraction would continuously emit GW in the bandwidth of the detectors. For the detector baselines, we consider advanced detector pairs among LCGT, LIGO, Virgo, ET, etc. Our results show that sufficient signal to noise can be accumulated with integration times of the order of a year if the ellipticity of neutron stars is larger than 10{sup -6}. The results improve for the multibaseline search. This analysis could as well be applied to other likely hot spots in the sky and other possible pairs of detectors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Calibration of photo sensors for the space-based cosmic ray telescope JEM-EUSO

In order to unveil the mystery of ultra-high energy cosmic rays (UHECRs), the planned fluorescence telescope JEM-EUSO (Extreme Universe Space Observatory on-board Japanese Experiment Module) will observe extensive air showers induced by UHECRs from the International Space Station (ISS) orbit with a huge acceptance. The JEM-EUSO instrument consists of Fresnel optics and a focal surface detector with 5000 multi-anode photomultiplier tubes (MAPMTs), 300000 channels in total. For fluorescence detection of cosmic rays it is essential to calibrate the detector pre-flight with utmost precision and to monitor the performance of the detector throughout the whole mission time. For that purpose a calibration stand on-ground was built to measure precisely the performance of Hamamatsu 64 pixel MAPMTs that are planned to be used for JEM-EUSO. To investigate the suitability of alternative detector devices, further research is done with state-of-the-art silicon photomultipliers (SiPMs), namely Hamamatsu multi-pixel photon counters (MPPCs). These will also be tested in the calibration stand and their performance can be compared to conventional photomultiplier tubes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Focal Plane Detectors for the Advanced Gamma-Ray Imaging System (AGIS)

The Advanced Gamma-Ray Imaging System (AGIS) is a concept for the next generation observatory in ground-based very high energy gamma-ray astronomy. Design goals are ten times better sensitivity, higher angular resolution, and a lower energy threshold than existing Cherenkov telescopes. Simulations show that a substantial improvement in angular resolution may be achieved if the pixel diameter is reduced to the order of 0.05 deg, i.e. two to three times smaller than the pixel diameter of current Cherenkov telescope cameras. At these dimensions, photon detectors with smaller physical dimensions can be attractive alternatives to the classical photomultiplier tube (PMT). Furthermore, the operation of an experiment with the size of AGIS requires photon detectors that are among other things more reliable, more durable, and possibly higher efficiency photon detectors. Alternative photon detectors we are considering for AGIS include both silicon photomultipliers (SiPMs) and multi-anode photomultipliers (MAPMTs). Here we present results from laboratory testing of MAPMTs and SiPMs along with results from the first incorporation of these devices into cameras on test bed Cherenkov telescopes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Perseverance’s Scanning Habitable Environments with Raman and Luminescence for Organics and Chemicals (SHERLOC) Investigation

The Scanning Habitable Environments with Raman and Luminescence for Organics and Chemicals (SHERLOC) is a robotic arm-mounted instrument on NASA’s Perseverance rover. SHERLOC has two primary boresights. The Spectroscopy boresight generates spatially resolved chemical maps using fluorescence and Raman spectroscopy coupled to microscopic images (10.1 μm/pixel). The second boresight is a Wide Angle Topographic Sensor for Operations and eNgineering (WATSON); a copy of the Mars Science Laboratory (MSL) Mars Hand Lens Imager (MAHLI) that obtains color images from microscopic scales (~13 μm/pixel) to infinity. SHERLOC Spectroscopy focuses a 40 μs pulsed deep UV neon-copper laser (248.6 nm), to a ~100 μm spot on a target at a working distance of ~48 mm. Fluorescence emissions from organics, and Raman scattered photons from organics and minerals, are spectrally resolved with a single diffractive grating spectrograph with a spectral range of 250 to ~370 nm. Because the fluorescence and Raman regions are naturally separated with deep UV excitation (<250 nm), the Raman region ~ 800 – 4000 cm -1 (250 to 273 nm) and the fluorescence region (274 to ~370 nm) are acquired simultaneously without time gating or additional mechanisms. SHERLOC science begins by using an Autofocus Context Imager (ACI) to obtain target focus and acquire 10.1 μm/pixel greyscale images. Chemical maps of organic and mineral signatures are acquired by the orchestration of an internal scanning mirror that moves the focused laser spot across discrete points on the target surface where spectra are captured on the spectrometer detector. ACI images and chemical maps (< 100 μm/mapping pixel) will enable the first Mars in situ view of the spatial distribution and interaction between organics, minerals, and chemicals important to the assessment of potential biogenicity (containing CHNOPS). Single robotic arm placement chemical maps can cover areas up to 7x7 mm in area and, with the < 10 min acquisition time per map, larger mosaics are possible with arm movements. This microscopic view of the organic geochemistry of a target at the Perseverance field site, when combined with the other instruments, such as Mastcam-Z, PIXL, and SuperCam, will enable unprecedented analysis of geological materials for both scientific research and determination of which samples to collect and cache for Mars sample return.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimization of an on-board imaging system for extremely rapid radiation therapy

Purpose: Next-generation extremely rapid radiation therapy systems could mitigate the need for motion management, improve patient comfort during the treatment, and increase patient throughput for cost effectiveness. Such systems require an on-board imaging system that is competitively priced, fast, and of sufficiently high quality to allow good registration between the image taken on the day of treatment and the image taken the day of treatment planning. In this study, three different detectors for a custom on-board CT system were investigated to select the best design for integration with an extremely rapid radiation therapy system. Methods: Three different CT detectors are proposed: low-resolution (all 4 × 4 mm pixels), medium-resolution (a combination of 4 × 4 mm pixels and 2 × 2 mm pixels), and high-resolution (all 1 × 1 mm pixels). An in-house program was used to generate projection images of a numerical anthropomorphic phantom and to reconstruct the projections into CT datasets, henceforth called “realistic” images. Scatter was calculated using a separate Monte Carlo simulation, and the model included an antiscatter grid and bowtie filter. Diagnostic-quality images of the phantom were generated to represent the patient scan at the time of treatment planning. Commercial deformable registration software was used to register the diagnostic-quality scan to images produced by the various on-board detector configurations. The deformation fields were compared against a “gold standard” deformation field generated by registering initial and deformed images of the numerical phantoms that were used to make the diagnostic and treatment-day images. Registrations of on-board imaging system data were judged by the amount their deformation fields differed from the corresponding gold standard deformation fields—the smaller the difference, the better the system. To evaluate the registrations, the pointwise distance between gold standard and realistic registration deformation fields was computed. Results: By most global metrics (e.g., mean, median, and maximum pointwise distance), the high-resolution detector had the best performance but the medium-resolution detector was comparable. For all medium- and high-resolution detector registrations, mean error between the realistic and gold standard deformation fields was less than 4 mm. By pointwise metrics (e.g., tracking a small lesion), the high- and medium-resolution detectors performed similarly. For these detectors, the smallest error between the realistic and gold standard registrations was 0.6 mm and the largest error was 3.6 mm. Conclusions: The medium-resolution CT detector was selected as the best for an extremely rapid radiation therapy system. In essentially all test cases, data from this detector produced a significantly better registration than data from the low-resolution detector and a comparable registration to data from the high-resolution detector. The medium-resolution detector provides an appropriate compromise between registration accuracy and system cost.

60 APPLIED LIFE SCIENCES↗

TU-FG-209-04: Testing of Digital Image Receptors Using AAPM TG-150’s Draft Recommendations - Investigating the Impact of Different Processing Parameters

Purpose: To evaluate implementation of AAPM TG-150’s draft recommendations via a parameter study for testing the performance of digital image receptors. Methods: Flat field images were acquired from 9 calibrated digital image receptors associated with 9 new portable digital radiography systems (Carestream Health, Inc.) based on the draft recommendations and manufacturer-specified calibration conditions (set of 4 images at input detector air kerma ranging from 1 to 25 µGy). Effects of exposure response function (linearized and logarithmic), ‘Presentation Intent Type’ (‘For Processing’ and ‘For Presentation’), detector orientation with respect to the anode-cathode axis (4 orientations; 900 rotations per iteration), different ROI sizes (5×5–40×40 mm{sup 2}) and elimination of varying dimensions of image border (0 mm i.e., without boundary elimination to 150 mm) on signal, noise, signal-to-noise ratio (SNR) and the associated nonuniformities were evaluated. Images were analyzed in Matlab and quantities were compared using ANOVA. Results: Signal, noise and SNR values averaged over 9 systems with default parameter values in draft recommendations were 4837.2±139.4, 19.7±0.9 and 246.4±10.1 (mean ± standard deviation), respectively (at input detector air kerma: 12.5 µGy). Signal, noise and SNR showed characteristic dependency on exposure response function and on ‘Presentation Intent Type’. These values were not affected by ROI size and detector orientation, but analysis showed that eliminating the edge pixels along the boundary was required for the noise parameter (coefficient of variation range for noise: 72%–106% and 3%–4% without and with boundary elimination; respectively). Local and global nonuniformities showed a similar dependence on the need for boundary elimination. Interestingly, computed non-uniformities showed agreement with manufacturer-reported values except for noise non-uniformities in two units; artifacts were seen in images from these two units highlighting the importance of independent evaluations. Conclusion: The effect of different parameters on performance characterization of digital image receptors was evaluated based on TG-150’s draft recommendations.

60 APPLIED LIFE SCIENCES↗

End-to-End Pipeline for Trigger Detection on Hit and Track Graphs

There has been a surge of interest in applying deep learning in particle and nuclear physics to replace labor-intensive offline data analysis with automated online machine learning tasks. This paper details a novel AI-enabled triggering solution for physics experiments in Relativistic Heavy Ion Collider and future Electron-Ion Collider. The triggering system consists of a comprehensive end-to-end pipeline based on Graph Neural Networks that classifies trigger events versus background events, makes online decisions to retain signal data, and enables efficient data acquisition. Here, the triggering system first starts with the coordinates of pixel hits lit up by passing particles in the detector, applies three stages of event processing (hits clustering, track reconstruction, and trigger detection), and labels all processed events with the binary tag of trigger versus background events. By switching among different objective functions, we train the Graph Neural Networks in the pipeline to solve multiple tasks: the edge-level track reconstruction problem, the edge-level track adjacency matrix prediction, and the graph-level trigger detection problem. We propose a novel method to treat the events as track-graphs instead of hit-graphs. This method focuses on intertrack relations and is driven by underlying physics processing. As a result, it attains a solid performance (around 72% accuracy) for trigger detection and outperforms the baseline method using hit-graphs by 2% higher accuracy.

97 MATHEMATICS AND COMPUTING↗

Beam test results for the Endcap Timing ReadOut Chip (ETROC2) for the CMS ETL upgrade

The Endcap Timing ReadOut Chip (ETROC) for the Compact Muon Solenoid (CMS) Minimum ionizing particle Timing Detector (MTD) is designed to process Low Gain Avalanche Diode (LGAD) signals with a time resolution of 40-50ps per hit, with 30-35 ps per charged particle using two layer detector. The ETROC2, is the first full size (16x16 pixels) and full functionally design that has been tested in hadron and electron beams at CERN and DESY (Sep 2023 - June 2024). Precision timing studies at these test beams are done using a self-referential beam telescope composed of up to 4 layers/chips. This talk describes the ETROC2 beam telescope and summarizes the performance of the ETROC2 chips bump-bonded to (16x16) Fondazione Bruno Kessler (FBK) and Hamamatsu Photonics K.K. (HPK) LGAD sensors using results from recent test beams. The experiences and lessons learned during the course of these test beams are also detailed in this talk.

Safdari, Murtaza↗

Digital Radiography of NIF RadHohl 09A Ta2O5 Target 54

Digital radiography data was collected for NIF RadHohl-09A Target 54 (MMED No.54, NDE No.T54). Three data sets were collected in order to: (1) characterize the relative density uniformity of the tantalum-oxide (Ta{sub 2}O{sub 5}) target material, (2) note readily-observable non-uniform features in the target, and (3) estimate the density of the target material. The Xradia Micro XCT system in B432 was used to collect the data. The system parameters were: (1) source: (a) x-ray energy = 49 kVp; and (b) power and current = 3.3 W and 66 {micro}A; (2) detector: (a) imaging optics magnifications = 4X, 20X; (b) effective pixel widths = 3.0 {micro}m (4X), 0.6 {micro}m (20X); and (c) integration time = 250 secs (5 frame-averaged 50-second integrations).

42 ENGINEERING↗

Cerenkov light images of EAS produced by primary gamma

It is shown that it should be possible to distinguish very effectively between background hadronic showers and TeV gamma ray showers from a point source on the basis of the width, length and orientation of the Cerenkov light images of the shower, seen in the focal plane of a focusing mirror, even with a relatively coarse pixel size such as employed in the Mt. Hopkins detector. Predictions of the response of this system to air showers are presented.

Hillas, A. M.↗

Support of the balloon-borne ultraviolet stellar spectrograph

A (256 x 1024)-pixel imaging ultraviolet Multi-mode Microchannel Array (MAMA) detector system for flight was fabricated, evaluated, and environmentally tested for flight on the Balloon Borne Ultraviolet Stellar Spectrograph (BUSS). The goal of the program was to replace the existing SEC Vidicon with the pulse-counting MAMA detector in order to, first, improve the overall sensitivity of the BUSS telescope and spectrograph for observations of stars down to m sub v = 7 and fainter, and, second, to improve the spectral resolution and wavelength accuracy by eliminating the image drifts in the Vidicon caused by magnetic field effects. A sealed MAMA detector tube structure employing a remotely processed photocathode mounted on a window in proximity focus with the front face of the MCP was developed to avoid contamination produced by a noisy and unstable device. The configuration of the BUSS detector system in its flight ready configuration is shown. The quantum efficiency curve for the semi-transparent Cs2Te photocathode is also shown.

Timothy, J. G.↗

The Extreme Ultraviolet Explorer and the local interstellar medium

The EUV Explorer (EUVE) mission is described, with emphasis on the overall capabilities of the instrumentation and the relevance of the mission to determining parameters of the local interstellar medium. The primary purpose of the mission is to search the celestial sphere for astronomical sources of EUV radiation (100-1000 A). The search will be accomplished with the use of three EUV telescopes, sensitive to different segments of the EUV band. A fourth telescope will perform a high-sensitivity search of a limited sample of the sky in the shortest-wavelength bands. The all-sky survey will be carried out in the first six months of the mission. The second six months of the mission, conducted entirely by Guest Investigators selected by NASA, will be devoted to spectroscopic observations of selected EUV sources. The instrumentation is now well developed. The best mirror has full-width/half-energy spread of 8 arcsec and a surface finish of 20 A. Prototype thin-film bandpass filters have been flown on the Space Shuttle and their performance optimized. Prototype detectors have been developed which have 600 by 600-pixel imaging capability and up to 80-percent quantum efficiency in parts of the EUV band.

Bowyer, Stuart↗