Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical elements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

High-speed digital fiber optic links for satellite traffic

Large aperture phased array antennas operating at millimeter wave frequencies are designed for space-based communications and imaging platforms. Array elements are comprised of active T/R modules which are linked to the central processing unit through high-speed fiber-optic networks. The system architecture satisfying system requirements at millimeter wave frequency is T/R level data mixing where data and frequency reference signals are distributed independently before mixing at the T/R modules. This paper demonstrates design procedures of a low loss high-speed fiber-optic link used for transmission of data signals over 600-900 MHz bandwidth inside satellite. The fiber-optic link is characterized for transmission of analog and digital data. A dynamic range of 79 dB/MHz was measured for analog data over the bandwidth. On the other hand, for bursted SMSK satellite traffic at 220 Mbps rates, BER of 2 x 10 to the -7th was measured for E(b)/N(o) of 14.3 dB.

Daryoush, A. S.↗

A Traceable Ground to On-Orbit Radiometric Calibration System for the Solar Reflective Wavelength Region

This paper describes the combination of a Mie scattering spectral BSDF and BTDF albedo standard whose calibration is traceable to the NIST SIRCUS Facility or the NIST STARR II Facility. The Space-based Calibration Transfer Spectroradiometer (SCATS) sensor uses a simple, invariant optical configuration and dedicated narrow band spectral channel modules to provide very accurate, polarization-insensitive, stable measurements of earth albedo and lunar disk albedo. Optical degradation effects on calibration stability are eliminated through use of a common optical system for observations of the Sun, Earth, and Moon. The measurements from space would be traceable to SI units through preflight calibrations of radiance and irradiance at NIST's SIRCUS facility and the invariant optical system used in the sensor. Simultaneous measurements are made in multiple spectral channels covering the solar reflective wavelength range of 300 nm to 2.4 microns. The large dynamic range of signals is handled by use of single-element, highly-linear detectors, stable discrete electronic components, and a non imaging optical configuration. Up to 19 spectral modules can be mounted on a single-axis drive to give direct pointing at the Earth and at least once per orbit view of the Sun and Moon. By observing the Sun on every orbit, the most stringent stability requirements of the system are limited to short time periods. The invariant optical system for both radiance and irradiance measurements also give excellent transfer to-orbit SI traceability. Emerging instrumental requirements for remotely sensing tropospheric trace species have led to a rethinking by some of the paradigm for Systeme International d'Unites (SI) traceability of the spectral irradiance and radiance radiometric calibrations to spectral albedo (sr(exp -1)) which is not a SI unit. In the solar reflective wavelength region the spectral albedo calibrations are tied often to either the spectral albedo of a solar diffuser or the Moon. This new type of Mie scattering diffuser (MSD) is capable of withstanding high temperatures, and is more Lambertian than Spectralon(tm). It has the potential of covering the entire solar reflective wavelength region. Laboratory measurements have shown that the specular reflectance component is negligible, and indicate that internal absorption by multiple scattering is small. This MSD, a true volume diffuser, exhibits a high degree of radiometric stability which suggests that measurements at the National Institute of Standards and Technology (NIST) could provide a spectral albedo standard. Measurements have been made of its radiometric stability under a simulated space environment of high energy gamma rays, high energy protons, and UV radiation from ambient down to the vacuum ultraviolet H Lyman alpha at 121.6 nm for its eventual use in space as a solar diffuser.

Heath, Donald F.↗

Implementation of a digital optical matrix-vector multiplier using a holographic look-up table and residue arithmetic

The design and implementation of a digital (numerical) optical matrix-vector multiplier are presented. The objective is to demonstrate the operation of an optical processor designed to minimize computation time in performing a practical computing application. This is done by using the large array of processing elements in a Hughes liquid crystal light valve, and relying on the residue arithmetic representation, a holographic optical memory, and position coded optical look-up tables. In the design, all operations are performed in effectively one light valve response time regardless of matrix size. The features of the design allowing fast computation include the residue arithmetic representation, the mapping approach to computation, and the holographic memory. In addition, other features of the work include a practical light valve configuration for efficient polarization control, a model for recording multiple exposures in silver halides with equal reconstruction efficiency, and using light from an optical fiber for a reference beam source in constructing the hologram. The design can be extended to implement larger matrix arrays without increasing computation time.

Habiby, Sarry F.↗

An ICP-OES method for the precise and accurate quantification of rare earth elements in natural water: A comparative study from mine waste sites in New Mexico, USA

Inductively coupled plasma techniques such as ICP-OES and ICP-MS are routinely used to determine the concentrations of rare earth elements (REE) in water samples. However, their performance for the determination of REE concentration in mine drainage waters from epithermal vein and porphyry copper mining districts has not been evaluated extensively. In this work, we develop an REE analysis method on an Agilent 5900 ICP-OES instrument and assess the accuracy and precision for the quantification of REE in the natural waters collected from mine adits and an acid seep of mine sites in the Steeple Rock and Hillsboro mining districts, New Mexico, USA. The total REE concentrations in the water samples were measured using the methods we developed for both ICP-OES and ICP-MS. The power of the new ICP-OES method lies in routine analysis of μg/L level concentrations normally analyzed using ICP-MS, including a U.S. Geological Survey standard reference sample, laboratory blank samples spiked with a National Institute of Standards and Technology traceable standard, and surface water samples from mine waste sites. This ICP-OES method achieves low quantification limits ranging from 0.2 to 5 μg/L and excellent analytical accuracy and precision for REE analysis. The precision of light (La-Gd) and heavy (Tb-Lu) REE analysis using this method are better than 5% at average concentrations above 5 ± 4 μg/L and 3 ± 2 μg/L, respectively, and 3% at average concentrations above 10 ± 9 μg/L and 5 ± 4 μg/L, respectively. This method also shows excellent sensitivity and reproducibility for our laboratory and field samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

New Phase Change Materials for Active Photonics

Phase change materials or PCMs are truly remarkable compounds whose unique switchable properties have fueled an explosion of emerging applications in electronics and photonics. Nonetheless, if we discount their use in optical discs, PCMs’ immense application potential in photonics beyond data recording has only begun to unfold in the past decade. While the material requirements for optical or electronic data storage have been succinctly summarized as five key elements “writability, archival storage, erasability, readability, and cyclability” decades ago, these requirements are not universally relevant to the diverse set of photonic applications now being explored. It also comes as no surprise that existing PCMs, which have been heavily vetted for data storage, are not necessarily the optimal compositions for different use cases in optics and photonics. PCMs with their attributes custom-tailored for specific applications are therefore in demand as phase-change photonics continue to expand. Here we discuss the PCM selection and design strategies specifically for photonic applications as well as our recent work developing active integrated photonic devices and metasurface optics based on new PCMs tailored for photonics.

phase change materials↗

Laboratory evaluation of Fecker and Loral optical IR PWI systems

A previous flight test of two electro-optical pilot warning indicators, using a flashing xenon strobe and silicon detectors as cooperative elements, pointed out several design deficiencies. The present laboratory evaluation program corrected these faults and calibrated the sensitivity of both systems in azimuth elevation and range. The laboratory tests were performed on an optical bench and consisted of three basic components: (1) a xenon strobe lamp whose output is monitored at the indicator detector to give pulse to pulse information on energy content at the receiver; (2) a strobe light attenuating optical system which is calibrated photometrically to provide simulated range; and (3) a positioning table on which the indicator system under study is mounted and which provides spatial location coordinates for all data points. The test results for both systems are tabulated.

Gorstein, M.↗

Approach to using 3D laser-induced breakdown spectroscopy (LIBS) data to explore the interaction of FLiNaK and FLiBe molten salts with nuclear-grade graphite

Nuclear graphite has historically been a key component of many nuclear reactor designs and has emerged as key to numerous advanced nuclear reactor design concepts. Molten salt reactors (MSRs) are one broad group of advanced reactor designs currently being pursued by industry for commercialization. Several MSR designs under consideration use graphitic materials that directly interface with a molten salt, whether it is a fuel salt, coolant salt, or both. Therefore, the interaction of graphite materials with molten salts must be understood. To gain this required understanding, a range of data is needed including porosity, strength, and composition as a function of different salt exposure parameters. In this study, a laser-induced breakdown spectroscopy (LIBS) measurement and data analysis methodology was developed to obtain spatially resolved elemental composition information for graphite samples exposed to a molten fluoride salt. Traditional univariate emission line analysis of atomic, ionic, and molecular optical emission signals was coupled via correlation analysis with spectral decomposition of the data using principal component analysis. Elemental depth profiling and elemental mapping were also performed to visualize salt–graphite interactions. LIBS was demonstrated to be useful for measuring key analytes such as fluorine and hydrogen, which are troublesome for other analysis techniques. Evidence for complex behavior was found, thereby demonstrating the usefulness of the developed approach for future systematic studies.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development of an earth resource pushbroom scanner utilizing a 90-element 8-14 micrometer /Hg,Cd/Te array

A detailed description is presented of thermal infrared 'pushbroom' scanners being developed for NASA's earth resources survey experiments in the middle to late 1980's. The devices offer high spectral, temporal and spatial resolution, and great reliability as well, due to simplicity of design. Their mode of operation does not require moving optics, since chopping and calibration are integral. The specific device described, a 90-element IR/CCD instrument, was developed to demonstrate scan imagery in the 8-14 micron spectral region in simulated aircraft tests. The scanning operation covers a straight-line path with a linear array of solid-state IR detectors, whose elements are activated sequentially in the cross-track direction while being swept forward along a flight path that, at an aircraft altitude of 10 km, is 7 km wide.

Brown, T. J.↗

Element abundances in the interstellar atomic material

In the interstellar medium, a significant fraction of the free atoms for elements heavier than helium must have condensed into solids, in the form of small, interstellar dust grains. Observations of optical and ultraviolet absorption lines in the spectra of hot stars indicate that the depletions below the cosmic abundances of various elements range from almost none at all to a factor of 0.0001 and seem to be enhanced along lines of sight with higher mean density. Other methods of measuring abundances confirm the absorption line results. The available evidence supports the notion that the grains form in both the atmospheres of cool stars and in dense interstellar clouds, and they are destroyed by shocks which frequently pass through the low density gas.

Jenkins, Edward B.↗

Thin, nearly wireless adaptive optical device

A thin, nearly wireless adaptive optical device capable of dynamically modulating the shape of a mirror in real time to compensate for atmospheric distortions and/or variations along an optical material is provided. The device includes an optical layer, a substrate, at least one electronic circuit layer with nearly wireless architecture, an array of actuators, power electronic switches, a reactive force element, and a digital controller. Actuators are aligned so that each axis of expansion and contraction intersects both substrate and reactive force element. Electronics layer with nearly wireless architecture, power electronic switches, and digital controller are provided within a thin-film substrate. The size and weight of the adaptive optical device is solely dominated by the size of the actuator elements rather than by the power distribution system.

Knowles, Gareth↗

Thin, nearly wireless adaptive optical device

A thin, nearly wireless adaptive optical device capable of dynamically modulating the shape of a mirror in real time to compensate for atmospheric distortions and/or variations along an optical material is provided. The device includes an optical layer, a substrate, at least one electronic circuit layer with nearly wireless architecture, an array of actuators, power electronic switches, a reactive force element, and a digital controller. Actuators are aligned so that each axis of expansion and contraction intersects both substrate and reactive force element. Electronics layer with nearly wireless architecture, power electronic switches, and digital controller are provided within a thin-film substrate. The size and weight of the adaptive optical device is solely dominated by the size of the actuator elements rather than by the power distribution system.

Knowles, Gareth↗

Thin nearly wireless adaptive optical device

A thin nearly wireless adaptive optical device capable of dynamically modulating the shape of a mirror in real time to compensate for atmospheric distortions and/or variations along an optical material is provided. The device includes an optical layer, a substrate, at least one electronic circuit layer with nearly wireless architecture, an array of actuators, power electronic switches, a reactive force element, and a digital controller. Actuators are aligned so that each axis of expansion and contraction intersects both substrate and reactive force element. Electronics layer with nearly wireless architecture, power electronic switches, and digital controller are provided within a thin-film substrate. The size and weight of the adaptive optical device is solely dominated by the size of the actuator elements rather than by the power distribution system.

Knowles, Gareth J.↗

A semi-analytical model for laser induced densification in fused silica at elevated temperatures

A semi-analytical model for deterministic surface smoothing of fused silica below the evaporation temperature threshold is presented. Using this model, a method for calculating deterministic track depths for laser polishing fused silica is derived and validated with experiments. In this work, model predictions were in good agreement with experiment across varying laser preheating temperature and power. With the semi-analytical method presented here, deterministic laser smoothing can be achieved in the densification regime to close the process loop of laser polishing.

36 MATERIALS SCIENCE↗

Modulating above-room-temperature magnetism in Ga-implanted Fe 5 GeTe 2 van der Waals magnets

The creation of van der Waals (vdW) ferromagnets with tunable Curie temperature (T C ) and magnetic anisotropy is essential in developing vdW magnet-based devices. Here, we report an effective and reliable method for modulating the magnetic properties of vdW Fe 5 GeTe 2 by site-specific Ga + implantation. In this study, we report an easy axis in the ab-plane for bulk Fe 5 GeTe 2 (T C = 310 K) and an axis out of the plane for thin Fe 5 GeTe 2 flakes (T C = 290 K). Combining element-resolved photoemission electron microscopy and spatially resolved magneto-optic Kerr microscopy, we find that the implantation of a tiny amount of 10 –3 Ga + ·Å –3 in Fe 5 GeTe 2 greatly enhances the T C from 290 to 360 K and switches the magnetic easy axis from the out-of-plane c axis to the ab-plane. The room-temperature x-ray magnetic circular dichroism signal is enhanced from 0% to 9% at an implantation level of 10 –2 Ga + ·Å –3 . These results provide new opportunities for tailoring the magnetic properties of vdW materials beyond room temperature.

36 MATERIALS SCIENCE↗

Assessment of errors in analytic modeling of permanent magnet electron spectrometers for laser-plasma accelerators

Here, we assess the error in three treatments of a critical electron beam diagnostic for laser-plasma acceleration (LPA) experiments: a permanent magnet electron spectrometer. Since LPA electron spectrometers are often difficult to calibrate due to the scarcity of well-characterized, tunable electron beam sources in the appropriate energy range and the mechanical complexity of electron spectrometers, the standard of calibration is Hall probe measurements. We first compare the electron spectrometer performance between SIMION calculations and the Hall probe measurements. We find up to a 60% (<8%) error in determining the absolute energy for electrons below (above) 80 MeV when using the SIMION-modeled magnetic field vs the measured magnetic field due to SIMION overpredicting fringe field strength. The difference in spectrometer energy resolution is within ∼10% between the modeled and measured fields. We then assess a simple block model, which is commonly used. We find that the simple block model presented here sufficiently captures the predicted as-built spectrometer performance for any application provided that the user can tolerate uncertainties on absolute energy determination up to 5% and errors on energy resolution up to 1%.

Electromagnetic optics↗

Effect of elastic anisotropy on thermally induced distortions of a laser beam in single cubic syngony crystals with radial cooling. Part I

We have studied thermally induced distortions of a beam in single cubic syngony crystals of all symmetry groups with an anisotropic elastic stiffness tensor. The arithmetic mean and the difference between the thermally induced phase incursions of eigenpolarisations, as well as the angle of incidence of these polarisations, are calculated for a long rod and a thin disk with radial cooling under uniform volume pumping of the active element. The position of the specific crystal orientations unrelated to its symmetry elements is investigated. The effective values of the thermo-optical constant Q in two specific orientations, as well as the thermo-optical constant P in an arbitrary orientation, are found. (invited paper)

36 MATERIALS SCIENCE↗

All-ceramic channel waveguides fabricated via 3D printing

All-ceramic channel waveguides (CWGs) in Yb:YAG transparent ceramics have been fabricated for the first time, to the best of our knowledge, via direct ink write (DIW) and their laser performance has been demonstrated. Single filaments of Yb:YAG nanoparticle-loaded ink were extruded into undoped YAG; the Yb:YAG filaments formed the CWGs, surrounded by undoped cladding. Elemental mapping confirmed the Yb doping profile and waveguide integrity. Optical characterization showed low cladding scatter losses (<1.3%/cm at 1.3 µm), and laser testing with a 940 nm Ti:sapphire pump demonstrated efficient lasing at 1030 nm. The best-performing waveguide, with an elliptical cross-section (100 µm × 60 µm and a length of 1.4 cm), achieved a slope efficiency of 61% and a roundtrip loss of 12.4%. These results identify DIW as a promising approach for fabricating high-performance channel waveguides in transparent ceramics.

36 MATERIALS SCIENCE↗