Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical Interferometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Search for Lensing Signatures in the Gravitational-Wave Observations from the First Half of LIGO–Virgo's Third Observing Run

We search for signatures of gravitational lensing in the gravitational-wave signals from compact binary coalescences detected by Advanced Laser Interferometer Gravitational-wave Observatory (LIGO) and Advanced Virgo during O3a, the first half of their third observing run. We study: (1) the expected rate of lensing at current detector sensitivity and the implications of a non-observation of strong lensing or a stochastic gravitational-wave background on the merger-rate density at high redshift; (2) how the interpretation of individual high-mass events would change if they were found to be lensed; (3) the possibility of multiple images due to strong lensing by galaxies or galaxy clusters; and (4) possible wave-optics effects due to point-mass microlenses. Several pairs of signals in the multiple-image analysis show similar parameters and, in this sense, are nominally consistent with the strong lensing hypothesis. However, taking into account population priors, selection effects, and the prior odds against lensing, these events do not provide sufficient evidence for lensing. Overall, we find no compelling evidence for lensing in the observed gravitational-wave signals from any of these analyses.

R. Abbott↗

21 cm Power Spectrum Analysis of North Celestial Pole Observations with the Tianlai Dish Pathfinder Array

The Tianlai Dish Pathfinder Array (TDPA) is a radio interferometer designed to test techniques for 21 cm intensity mapping in the post-reionization Universe as a means of measuring large-scale cosmic structure. Using nine nights of observations targeting the North Celestial Pole field, totaling approximately 107 hr of integration time, we analyze data in the frequency range 700–800 MHz (corresponding to redshift z ∼ 0.9). We do the data format conversion, radio frequency interference flagging, calibration, imaging and point source subtraction, and foreground removal via Singular Value Decomposition. The spherically averaged power spectrum Δ 2 (k) is obtained. Furthermore, this work successfully establishes and validates a comprehensive data analysis framework for the TDPA. We identify key improvements including sky model refinement, increased integration time, and pipeline optimization that will enable future detection of the 21 cm signal through auto-correlation and cross-correlation with optical galaxy surveys.

cosmology: large-scale structure of universe↗

Tidbinbilla two-element interferometer

A phase-stable two-element interferometer has been formed by linking the 64- and 34-m antennas of the Deep Space Network at Tidbinbilla, Australia. Utilizing the existing first-stage maser receivers at 2.3 GHz to yield a system temperature of approximately 20 K, the system has a 5 sigma detection sensitivity of 50 mJy in 1 s, with a rms confusion of approximately 6 mJy. The 195-m north-south baseline permits positional measurements to approximately 2 arcsec of sources stronger than approximately 100 mJy over the declination range -80 to +30 deg. Such measurements are ideally suited for the optical identification of weak radio sources. It is planned to extend the frequency of operation of the instrument to 8.4 GHz in the near future.

Batty, M. J.↗

Orbital station-keeping for multiple spacecraft interferometry

This paper presents a three-satellite station-keeping strategy that is applicable to very long (1-100 km) baseline optical interferometry in space using the 'free-flyer' approach. The relative positions of the satellites in an arbitrarily oriented inertial coordinate system are described parametrically, and the continuous thrust vectors required to follow the paths are derived. The paths, which are constrained to be in the U-V plane of an astronomical source (a plane perpendicular to the direction of the source), are always chosen to maximize the use of gravity gradient forces and minimize the use of thrusting which can easily be provided by ion thrusters. Two different thrust programs are presented. One allows the interferometer to take data over an elliptic-shaped area of the U-V plane of arbitrary size for astronomical sources in any direction except close to the orbit plane of the system. The second thrust program reorients the U-V plane from one arbitrary source direction to another.

Decou, Anthony B.↗

LOITA: Lunar Optical/Infrared Telescope Array

LOITA (Lunar Optical/Infrared Telescope Array) is a lunar-based interferometer composed of 18 alt-azimuth telescopes arranged in a circular geometry. This geometry results in excellent uv coverage and allows baselines up to 5 km long. The angular resolution will be 25 micro-arcsec at 500 nm and the main spectral range of the array will be 200 to 1100 nm. For infrared planet detection, the spectral range may be extended to nearly 10 mu m. The telescope mirrors have a Cassegrain configuration using a 1.75 m diameter primary mirror and a 0.24 m diameter secondary mirror. A three-stage (coarse, intermediate, and fine) optical delay system, controlled by laser metrology, is used to equalize path lengths from different telescopes to within a few wavelengths. All instruments and the fine delay system are located within the instrument room. Upon exiting the fine delay system, all beams enter the beam combiner and are then directed to the various scientific instruments and detectors. The array instrumentation will consist of CCD detectors optimized for both the visible and infrared as well as specially designed cameras and spectrographs. For direct planet detection, a beam combiner employing achromatic nulling interferometry will be used to reduce star light (by several orders of magnitude) while passing the planet light. A single telescope will be capable of autonomous operation. This telescope will be equipped with four instruments: wide field and planetary camera, faint object camera, high resolution spectrograph, and faint object spectrograph. These instruments will be housed beneath the telescope. The array pointing and control system is designed to meet the fine pointing requirement of one micro-arcsec stability and to allow precise tracking of celestial objects for up to 12 days. During the lunar night, the optics and the detectors will be passively cooled to 70-80 K temperature. To maintain a continuous communication with the earth a relay satellite placed at the L4 libration point will be used in conjunction with the Advanced Tracking and Data Relay Satellite System (ATDRSS). Electrical power of about 10 kW will be supplied by a nuclear reactor based on the SP-100 technology. LOITA will be constructed in three phases of six telescopes each. The total mass of the first operational phase is estimated at 58,820 kg. The cost of the fully operational first phase of the observatory is estimated at $8.9 billion. LOITA's primary objectives will be to detect and characterize planets around nearby stars (up to ten parsec away), study physics of collapsed stellar objects, solar/stellar surface features and the processes in nuclear regions of galaxies and quasars. An interferometric array such as LOITA will be capable of achieving resolutions three orders of magnitude greater than Hubble's design goal. LOITA will also be able to maintain higher signal to noise ratios than are currently attainable due to long observation times available on the moon.

Source record↗

Vacuum Nuller Testbed Performance, Characterization and Null Control

The Visible Nulling Coronagraph (VNC) can detect and characterize exoplanets with filled, segmented and sparse aperture telescopes, thereby spanning the choice of future internal coronagraph exoplanet missions. NASA/Goddard Space Flight Center (GSFC) has developed a Vacuum Nuller Testbed (VNT) to advance this approach, and assess and advance technologies needed to realize a VNC as a flight instrument. The VNT is an ultra-stable testbed operating at 15 Hz in vacuum. It consists of a MachZehnder nulling interferometer; modified with a "W" configuration to accommodate a hexpacked MEMS based deformable mirror (DM), coherent fiber bundle and achromatic phase shifters. The 2-output channels are imaged with a vacuum photon counting camera and conventional camera. Error-sensing and feedback to DM and delay line with control algorithms are implemented in a real-time architecture. The inherent advantage of the VNC is that it is its own interferometer and directly controls its errors by exploiting images from bright and dark channels simultaneously. Conservation of energy requires the sum total of the photon counts be conserved independent of the VNC state. Thus sensing and control bandwidth is limited by the target stars throughput, with the net effect that the higher bandwidth offloads stressing stability tolerances within the telescope. We report our recent progress with the VNT towards achieving an incremental sequence of contrast milestones of 10(exp 8) , 10(exp 9) and 10(exp 10) respectively at inner working angles approaching 2A/D. Discussed will be the optics, lab results, technologies, and null control. Shown will be evidence that the milestones have been achieved.

Lyon, R. G.↗

NASA Tech Briefs, April 2010

Topics covered include: Active and Passive Hybrid Sensor; Quick-Response Thermal Actuator for Use as a Heat Switch; System for Hydrogen Sensing; Method for Detecting Perlite Compaction in Large Cryogenic Tanks; Using Thin-Film Thermometers as Heaters in Thermal Control Applications; Directional Spherical Cherenkov Detector; AlGaN Ultraviolet Detectors for Dual-Band UV Detection; K-Band Traveling-Wave Tube Amplifier; Simplified Load-Following Control for a Fuel Cell System; Modified Phase-meter for a Heterodyne Laser Interferometer; Loosely Coupled GPS-Aided Inertial Navigation System for Range Safety; Sideband-Separating, Millimeter-Wave Heterodyne Receiver; Coaxial Propellant Injectors With Faceplate Annulus Control; Adaptable Diffraction Gratings With Wavefront Transformation; Optimizing a Laser Process for Making Carbon Nanotubes; Thermogravimetric Analysis of Single-Wall Carbon Nanotubes; Robotic Arm Comprising Two Bending Segments; Magnetostrictive Brake; Low-Friction, Low-Profile, High-Moment Two-Axis Joint; Foil Gas Thrust Bearings for High-Speed Turbomachinery; Miniature Multi-Axis Mechanism for Hand Controllers; Digitally Enhanced Heterodyne Interferometry; Focusing Light Beams To Improve Atomic-Vapor Optical Buffers; Landmark Detection in Orbital Images Using Salience Histograms; Efficient Bit-to-Symbol Likelihood Mappings; Capacity Maximizing Constellations; Natural-Language Parser for PBEM; Policy Process Editor for P(sup 3)BM Software; A Quality System Database; Trajectory Optimization: OTIS 4; and Computer Software Configuration Item-Specific Flight Software Image Transfer Script Generator.

Source record↗

Characterization of groove density variation of VLS gratings with ALS XROL LTP-II in different operation modes

The long trace profiler, LTP-II, available at the Advanced Light Source (ALS) X-ray Optics Laboratory (XROL), was recently upgraded by replacing a multimode diode laser light source with a single-mode, wavelength-stabilized, fibercoupled diode laser system. The upgrade enables us to reliably characterize the lateral variation of groove density of variable-line-spacing (VLS) x-ray diffraction gratings. Here, we discuss the LTP-II performance with an example of measurements with a VLS grating with the groove density at the grating center of 300 lines/mm. For the measurements, we use the LTP-II in two different operation arrangements, the single Gaussian beam and the pencil beam interferometer arrangements. For each operation arrangement, we apply two data processing algorithms: with calculating the centroid position and with determining the position of a characteristic features of the detected beam intensity distributions. Additionally, we discuss the observed strong correlation between the LTP-II modes of operation and the resulted (extracted) groove density variations. We also speculate on possible origin of the correlation.

42 ENGINEERING↗

A kinematic and proper-motion survey of the Cygnus Loop

H-alpha radial velocities, line widths, and line intensities based on 71 Fabry-Perot interferometer scans of 61 fields in the Cygnus Loop supernova remnant SNR are reported. Also, measurements of proper motions at 39 locations within the Cygnus Loop are summarized. These results show that the remnant is expanding asymmetrically into the ambient interstellar medium, with rest-frame velocities as high as 380 km/s in the near half and 150 km/s in the far half. This can plausibly be interpreted as the result of the progenitor's evolution near a density discontinuity, the consequent formation of a cavity and partial shell, and the SN's interaction with that shell. The remnant's optically observed filamentary structure results from line-of-sight effects as shock waves advance into the irregular inner surface of the shell. In this context, the derived expansion velocities and proper motions give a formal distance to the Cygnus Loop of roughly 600 pc, with 1-sigma limits of 300 and 1200 pc.

Shull, Peter, Jr.↗

Correlation polarimeter-interferometer in the DIII-D tokamak

A correlation polarimeter-interferometer system has been developed for the DIII-D tokamak to detect small amplitude magnetic and density fluctuations. Two collinear, frequency-offset (5–15 MHz), orthogonally polarized (right- and left-handed, circularly polarized) electromagnetic waves at 650 GHz probing the plasma are used to detect the Faraday effect. A third, linearly polarized, electromagnetic wave serves as the local-oscillator to provide a measure of the line-averaged density. Correlation polarimetric measurement is accomplished by correlating the Faraday effect measured along the same line of sight using two independent detectors, whereas simultaneous correlation interferometric measurement is realized by correlating the line-averaged density measured at two different intermediate frequencies. The noise floor of the correlation polarimeter-interferometer has been demonstrated to be more than one order of magnitude lower than that of a standard polarimeter-interferometer measurement. Line-averaged correlation polarimetric-interferometric measurements in DIII-D H-mode plasmas show broadband (up to 750 kHz) magnetic and density fluctuations with amplitudes as low as 0.03 $Gauss$/$\sqrt{kHz}$ and 4 × 10 13 m –3 /$\sqrt{kHz}$, respectively.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Designing high-power, octave spanning entangled photon sources for quantum spectroscopy

Entangled photon spectroscopy is a nascent field that has important implications for measurement and imaging across chemical, biology, and materials fields. Entangled photon spectroscopy potentially offers improved spatial and temporal-frequency resolutions, increased cross sections for multiphoton and nonlinear measurements, and new abilities in inducing or measuring quantum correlations. A critical step in enabling entangled photon spectroscopies is the creation of high-flux entangled sources that can use conventional detectors as well as provide redundancy for the losses in realistic samples. Here, we report a periodically poled, chirped, lithium tantalate platform that generates entangled photon pairs with ~10 -7 efficiency. For a near watt level diode laser, this results in a near μW-level flux. The single photon per mode limit that is necessary to maintain non-classical photon behavior is still satisfied by distributing this power over up to an octave-spanning bandwidth. The spectral–temporal photon correlations are observed via a Michelson-type interferometer that measures the broadband Hong–Ou–Mandel two-photon interference. A coherence time of 245 fs for a 10 nm bandwidth in the collinear case and a coherence time of 62 fs for a 125 nm bandwidth in the non-collinear case are measured using a CW pump laser and, essentially, collecting the full photon cone. We outline in detail the numerical methods used for designing and tailoring the entangled photons source, such as changing center wavelength or bandwidth, with the ultimate aim of increasing the availability of high-flux UV–Vis entangled photon sources in the optical spectroscopy community.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dense gas and HII regions in the starburst galaxy NGC 253

The energetic activity in the nuclear barred region of NGC 253 is attributable to a burst of star formation. NGC 253 is in many ways a twin of the prototypical starburst galaxy M82; the strong non-thermal radio continuum, high far-infrared luminosity, and bright molecular emission of the central 1 Kpc parallel the morphology of the M82 starburst. Furthermore, the filamentary low ionization optical emission and extended x ray emission along the minor axis in NGC 253 is similar to a scaled down version of the well developed galactic bipolar wind in M82. The infrared luminosity of NGC 253, 3(exp 10) solar luminosity, is comparable to M82 but is emitted from a smaller region (Telesco and Harper 1980). This suggests that the NGC 253 starburst may be more intense and at an earlier evolutionary stage than M82. However, the presence of a non-stellar AGN in NGC 253 may complicate the comparison (Turner and Ho, 1985). Researchers used the Hat Creek millimeter interferometer to map emission from the J = 1 to 0 transitions of HCN and HCO(+) as well as 3 mm continuum emission, toward the nuclear region of NGC 253. The HCO(+) and continuum observations are sensitive to spatial scales from 6 to 45 seconds. The 2 minute field of view comfortably includes the entire starburst region (about 40 seconds; 650 pc). Because the longer baseline HCN observations are not yet complete, they are only sensitive to spatial scales from 15 to 45 seconds.

Carlstrom, J. E.↗

Laboratory Apparatus Generates Dual-Species Cold Atomic Beam

A laser cooling apparatus that generates a cold beam of rubidium and cesium atoms at low pressure has been constructed as one of several intermediate products of a continuing program of research on laser cooling and atomic physics. Laser-cooled atomic beams, which can have temperatures as low as a microkelvin, have been used in diverse applications that include measurements of fundamental constants, atomic clocks that realize the international standard unit of time, atom-wave interferometers, and experiments on Bose-Einstein condensation. The present apparatus is a prototype of one being evaluated for use in a proposed microgravitational experiment called the Quantum Interferometric Test of Equivalence (QuITE). In this experiment, interferometric measurements of cesium and rubidium atoms in free fall would be part of a test of Einstein s equivalence principle. The present apparatus and its anticipated successors may also be useful in other experiments, in both microgravity and normal Earth gravity, in which there are requirements for dual-species atomic beams, low temperatures, and low pressures. The apparatus includes a pyramidal magneto-optical trap in which the illumination is provided by multiple lasers tuned to frequencies characteristic of the two atomic species. The inlet to the apparatus is located in a vacuum chamber that contains rubidium and cesium atoms at a low pressure; the beam leaving through the outlet of the apparatus is used to transfer the atoms to a higher-vacuum (lower-pressure) chamber in which measurements are performed. The pyramidal magneto-optical trap is designed so that the laser cooling forces in one direction are unbalanced, resulting in a continuous cold beam of atoms that leak out of the trap (see figure). The radiant intensity (number of atoms per unit time per unit solid angle) of the apparatus is the greatest of any other source of the same type reported to date. In addition, this is the first such apparatus capable of producing a slow, collimated beam that contains two atomic species at the same time.

Thompson, Robert↗

Lunar accelerometer network gravitational observatory (LANGO)

With ground-based interferometers detecting hundreds of gravitational-wave (GW) events, GW astronomy has continued to blossom. U.S. and European scientists are developing plans to construct third-generation ground-based interferometers. ESA has proceeded through the mission formulation phase of space-based interferometer in a lower-frequency band, 10 –4 –0.1 Hz. Despite all these exciting developments, there is still a missing frequency band, 0.1–10 Hz. This mid-frequency band is rich with interesting astrophysical events. Coalescence and merger of intermediate-mass black holes (IMBHs) will occur in this frequency band. Coalescing stellar-mass BHs will pass through this frequency band days before they reach the frequency band of LIGO and Virgo. Detection of such signals would enable a mid-frequency detector to issue an advance notice to the high-frequency GW detectors, as well as to optical, x-ray and γ-ray telescopes. We propose Lunar Accelerometer Network Gravitational Observatory (LANGO) to detect GWs in this frequency band. In the first phase (LANGO 1), we propose to deploy four ambient-temperature (250 K) accelerometers in the tetrahedral or in a square configuration on the hemisphere facing the Earth. After successful operation at 250 K, LANGO would be upgraded to a cryogenic (4 K) version with over two orders of magnitude increased sensitivity (LANGO 2), with coherent rejection of seismic noise implemented. LANGO is a full-tensor detector, capable of determining the source direction and wave polarization. Each test mass (TM) is suspended as a pendulum with resonance frequency ∼ 0.01 Hz, thus is only weakly coupled to the lunar surface horizontally. LANGO is designed to detect the relative motion of globally separated, nearly free, TMs by using the Moon as a large quiet platform. LANGO 1 and 2 accelerometers aim at sensitivities ⩽ 10 –11 m s –2 Hz –1/2 and ⩽ 10 –13 m s –2 Hz –1/2 in the horizontal axes over the frequency band of 1 mHz–10 Hz, which yield GW sensitivities 1.1 x 10 -21 Hz -1/2 and 3.8 x 10 -24 Hz -1/2 at 1 Hz, respectively. The LANGO accelerometers will be 10 3 –10 5 times more sensitive than Apollo seismometers. With such sensitivity, LANGO will also make great contribution to the advancement of lunar geophysics.

79 ASTRONOMY AND ASTROPHYSICS↗

LISA Mission Concept Study, Laser Interferometer Space Antenna for the Detection and Observation of Gravitational Waves

This document presents the results of a design feasibility study for LISA (Laser Interferometer Space Antenna). The goal of LISA is to detect and study low-frequency astrophysical gravitational radiation from strongly relativistic regions. Astrophysical sources potentially visible to LISA include extra-galactic massive black hole binaries at cosmological distances, binary systems composed of a compact star and a massive black hole, galactic neutron star-black hole binaries, and background radiation from the Big Bang. The LISA mission will comprise three spacecraft located five million kilometers apart forming an equilateral triangle in an Earth-trailing orbit. Fluctuations in separation between shielded test masses located within each spacecraft will be determined by optical interferometry which determines the phase shift of laser light transmitted between the test masses.

Folkner, W. M.↗

Cryogenic (70K) measurement of an all-composite 2-meter diameter mirror

The Herschel Space observatory (formerly known as FIRST) consists of a 3.5 m space telescope. In order to develop lightweight telescope technology suitable for this mission, COI designed and fabricated aspherical, f/1 2 m aperture prototype primary mirror using solely carbon fiber reinforced polypmer (CFR) materials. To assess the performance of this technology, optical metrology of the mirror surface was performed from ambient to an intended operational temperature for IR-telescopes of 70K. Testing was performed horizontally in a cryogenic vacuum chamber at Arnold Engineering Development Center (AEDC), Tennessee.

lightweight mirrors cryogenic testing composite ma↗

A Dispersive Backend Design for the 'Double-Fourier' Interferometer BETTII

BETTII (Balloon Experimental Twin Telescope for Infra-red Interferometry) is designed to provide high angular resolution spectroscopic data in the far-infrared (FIR) wavelengths. The most significant limitation for BETTII is its sensitivity; obtaining spectral signal-to-noise ratio greater than 5 in less than 10 minutes requires sources greater than 13 Janskys (Jy). One possible way to improve the signal-to-noise ratio (SNR) for future BETTII flights is by reducing the spectral bandwidth post beam-combination. This involves using a dispersive element to spread out a polychromatic point source PSF (Point Spread Function) on the detector array, such that each pixel corresponds to a small fraction of the bandwidth. This results in a broader envelope of the interferometric fringe pattern allowing more fringes to be detected, and thereby improving the spectral SNR. Here we present the analysis and optical design of the dispersive backend, discussing the tradeoffs and how it can be combined with the existing design.

Dhabal, Arnab↗

Time-Average Measurement of Velocity, Density, Temperature, and Turbulence Using Molecular Rayleigh Scattering

Measurement of time-averaged velocity, density, temperature, and turbulence in gas flows using a nonintrusive, point-wise measurement technique based on molecular Rayleigh scattering is discussed. Subsonic and supersonic flows in a 25.4-mm diameter free jet facility were studied. The developed instrumentation utilizes a Fabry-Perot interferometer to spectrally resolve molecularly scattered light from a laser beam passed through a gas flow. The spectrum of the scattered light contains information about velocity, density, and temperature of the gas. The technique uses a slow scan, low noise 16-bit depth CCD camera to record images of the fringes formed by Rayleigh scattered light passing through the interferometer. A kinetic theory model of the Rayleigh scattered light is used in a nonlinear least squares fitting routine to estimate the unknown parameters from the fringe images. The ability to extract turbulence information from the fringe image data proved to be a challenge since the fringe is broadened by not only turbulence, but also thermal fluctuations and aperture effects from collecting light over a range of scattering angles. Figure 1 illustrates broadening of a Rayleigh spectrum typical of flow conditions observed in this work due to aperture effects and turbulence for a scattering angle, chi(sub s), of 90 degrees, f/3.67 collection optics, mean flow velocity, u(sub k), of 300 m/s, and turbulent velocity fluctuations, sigma (sub uk), of 55 m/s. The greatest difficulty in processing the image data was decoupling the thermal and turbulence broadening in the spectrum. To aid in this endeavor, it was necessary to seed the ambient air with smoke and dust particulates; taking advantage of the turbulence broadening in the Mie scattering component of the spectrum of the collected light (not shown in the figure). The primary jet flow was not seeded due to the difficulty of the task. For measurement points lacking particles, velocity, density, and temperature information could reliably be recovered, however the turbulence estimates contained significant uncertainty. Resulting flow parameter estimates are presented for surveys of Mach 0.6, 0.95, and 1.4 jet flows. Velocity, density, and temperature were determined with accuracies of 5 m/s, 1.5%, and 1%, respectively, in flows with no particles present, and with accuracies of 5 m/s, 1-4%, and 2% in flows with particles. Comparison with hotwire data for the Mach 0.6 condition demonstrated turbulence estimates with accuracies of about 5 m/s outside the jet core where Mie scattering from dust/smoke particulates aided in the estimation of turbulence. Turbulence estimates could not be recovered with any significant accuracy for measurement points where no particles were present.

Mielke, Amy F.↗