Control of SiC Based Integrated DC-DC Powertrain Charger for Electric Vehicles

In this paper, an automated controller for an integrated, reconfigurable dc-dc converter for plugin electric vehicles (EVs) is presented. The integrated converter combines both an interleaved boost converter and dual active bridge (DAB) converter, sharing magnetics and switching devices. The converter switches between operating modes using the existing battery management system (BMS) contactors. The integrated converter operates in isolated DAB mode during battery charging operation. During traction operation, the integrated converter is operated in interleaved boost mode for heavy load and DAB mode during light load, high voltage operation. An online transition algorithm is used to transition from interleaved boost mode to DAB mode with minimal bus distortion. The automated controller selects the operating mode and inverter bus voltage at different torque-speed conditions to get maximum overall traction drive efficiency. An experimental prototype of the integrated converter demonstrates the automated controller functionality.

Anwar, Saeed↗

Adaptive Internal Model Based Current Control with Embedded Active Damping of a Three-Phase Grid-Connected Inverter with LCL Filter for PV Application

This paper presents an internal model based controller with embedded active damping for a three-phase grid-connected inverter with LCL filter. A strategy to control the grid current based on the internal model principle is presented in this paper. It is known that a third-order LCL filter apart from providing better attenuation also poses the problem of initiating unwanted resonance oscillations especially during transients. To address this problem, an active damping strategy based on virtual resistance emulation on the grid side filter is implemented. Also, to ensure effective active damping, an online parameter update strategy is implemented for the filter parameters. The proposed method provides better attenuation to oscillation damping and achieves good tracking performance without adversely affecting the bandwidth. The architecture is verified based on computer simulations via MATLAB/Simulink and PLECS domain and various important case study results are presented.

grid-connected inverter↗

A Robust Method to Secure Multi-Inverter Grid Tied PV and Battery Energy Storage Systems Against Cyber Intrusions

This paper details a robust method to secure a multi-inverter grid tied system that interfaces photovoltaic (PV) and battery energy storage against potential cyber-attacks. The method can be applied to any third-party inverter systems without a need to modify their internal controls. A small random private excitation signal termed "watermark" is injected into the DC input voltage terminals (via a series transformer) connected to the PV/battery inverter system. An external robust cyber intrusion detector (CID) hardware consisting of a digital signal processor (DSP) generates the "watermark" and also receives the sensor signals that control the setpoints of the PV/battery grid tied system. The CID algorithm is shown to detect all possible cyber intrusions (such as false data injection(FDI)) on external sensor signals such as P and Q measured by a smart meter that control the overall system operation. The proposed CID computes online system ID and two variance tests in real time on each sensor signal and is able pinpoint intrusion location in a multi-inverter system. Results on a hardware in the loop (HIL) of a two-inverter grid connected system demonstrate effectiveness of the proposed CID system for FDI and unobservable FDI. Test results on a laboratory prototype will be discussed in the conference presentation.

Ibrahim, Hasan↗

System Identification of a DC-DC Buck Converter Based on Two-Channel Relay Method

This work presents a system identification approach based on a two-channel relay applied to a DC-DC buck converter operating in closed-loop with a PI controller to regulate its output voltage. The implemented two-relay method allows system identification while the system is running online. Moreover, the algorithm works in a closed-loop configuration while introducing a minimal perturbation in the converter's operation. The presented algorithm was used to identify the frequency response of the converter with no-prior knowledge about the system structure. Furthermore, the identified transfer function parameters has a good agreement with the mathematical model of the converter. Simulation results of the comparison between the switching model, mathematical model and the identified model are provided to validate the theoretical analysis.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Offline Arterial Signal Timing Optimization for Closely Spaced Intersections

The stop-and-go driving behavior at a busy arterial causes a significant amount of fuel waste and emissions that could be reduced. For closely spaced intersections, the traditional bottom-up signal timing approach could fail under high volumes when the queues reach the upstream intersections. A well-coordinated arterial should manage the queue length to prevent the control from failing. Traditionally, coordination among signalized intersections for an arterial means finding the good offsets for each intersection. The control of the intersections along an arterial can also be coordinated by optimizing splits. Splits impact the capacity of an intersection. Similar to the highway, the capacity drop could cause growing queues. This work is based on the Virtual Phase-Link (VPL) model, a street traffic model designed for online traffic model predictive control, to obtain a top-down offline arterial signal timing. The VPL-based model can guarantee capacity consistency in intersections along an arterial. We, therefore, adopted the VPL-based model and developed an offline signal timing optimization approach. The proposed timing derived from the VPL-based offline signal timing optimization showed very good results in simulation. We also collected field experiment data, which demonstrated overall energy reductions and speed improvements on some sections of the study arterial.

47 OTHER INSTRUMENTATION↗

When ChatGPT Meets Vulnerability Management: The Good, the Bad, and the Ugly

Vulnerability management is a very challenging and time-consuming task. For many organizations, security operators need to learn about the properties of vulnerabilities to prioritize and mitigate them. Due to the lack of automated tools for vulnerability assessment, operators usually manually search for and read related information from sources online. Recent advances in large language models, like ChatGPT, open up an opportunity for time savings and may prompt operators to use these models as vulnerability information sources. In this work, we evaluate the ability of ChatGPT and several of its siblings to accurately answer user questions about vulnerability properties as well as to provide information for how to mitigate a vulnerability. We also explore their summarization capabilities when multiple vulnerability advisory documents are provided. We find that the models perform poorly on information retrieval tasks, but they perform quite well on summarization.

McClanahan, Kylie↗

Descriptor: High Temporal Resolution Meteorological Data at Oak Ridge Reservation (ORR-HiResMet)

Access to continuous, quality assessed meteorological data is critical for understanding the climatology and atmospheric dynamics of a region. Research facilities like Oak Ridge National Laboratory (ORNL) rely on such data to assess site-specific climatology, model potential emissions, establish safety baselines, and prepare for emergency scenarios. To meet these needs, on-site towers at ORNL collect meteorological data at 15-minute and hourly intervals. However, data measurements from meteorological towers are affected by sensor sensitivity, degradation, lightning strikes, power fluctuations, glitching, and sensor failures, all of which can affect data quality. To address these challenges, we conducted a comprehensive quality assessment and processing of five years of meteorological data collected from ORNL at 15-minute intervals, including measurements of temperature, pressure, humidity, wind, and solar radiation. The time series of each variable was pre-processed and gap-filled using established meteorological data collection and cleaning techniques, i.e., the time series were subjected to structural standardization, data integrity testing, automated and manual outlier detection, and gap-filling. The data product and highly generalizable processing workflow developed in Python Jupyter notebooks are publicly accessible online. As a key contribution of this study, the evaluated 5-year data will be used to train atmospheric dispersion models that simulate dispersion dynamics across the complex ridge-and-valley topography of the Oak Ridge Reservation in East Tennessee.

Steckler, Morgan R. [Oak Ridge National Laboratory↗

NISQ+: Boosting quantum computing power by approximating quantum error correction

Quantum computers are growing in size, and design decisions are being made now that attempt to squeeze more computation out of these machines. In this spirit, we design a method to boost the computational power of near-term quantum computers by adapting protocols used in quantum error correction to implement "Approximate Quantum Error Correction (AQEC)." By approximating fully-fledged error correction mechanisms, we can increase the compute volume (qubits × gates, or "Simple Quantum Volume (SQV)") of near-term machines. The crux of our design is a fast hardware decoder that can approximately decode detected error syndromes rapidly. Specifically, we demonstrate a proof-of-concept that approximate error decoding can be accomplished online in near-term quantum systems by designing and implementing a novel algorithm in Single-Flux Quantum (SFQ) superconducting logic technology. This avoids a critical decoding backlog, hidden in all offline decoding schemes, that leads to idle time exponential in the number of T gates in a program. Our design utilizes one SFQ processing module per physical qubit. Employing state-of-the-art SFQ synthesis tools, we show that the circuit area, power, and latency are within the constraints of contemporary quantum system designs. Under pure dephasing error models, the proposed accelerator and AQEC solution is able to expand SQV by factors between 3,402 and 11,163 on expected near-term machines. The decoder achieves a 5% accuracy-threshold and pseudo-thresholds of ~ 5%,4.75%,4.5%, and 3.5% physical error-rates for code distances 3,5,7, and 9. Decoding solutions are achieved in a maximum of ~20 nanoseconds on the largest code distances studied. By avoiding the exponential idle time in offline decoders, we achieve a 10x reduction in required code distances to achieve the same logical performance as alternative designs.

97 MATHEMATICS AND COMPUTING↗

A Privacy-Aware Federated Learning Framework for Distributed Energy Resource Analytics in Constrained Environments

To be resilient against extreme weather events, the rural communities in Puerto Rico are leveraging distributed energy resources (DER). However, computing frameworks sup-porting the grid in critical decision-making are still largely centralized. Sensitive consumer data are transmitted over the Internet or cellular networks to a secondary or tertiary node. It guarantees better situational awareness at the cost of a wider attack surface, jeopardizing user privacy, as more DER come online. Cloud, Edge, and Fog computing all require data aggregation at some level. This paper introduces a privacy-aware federated learning framework that leverages the Fog model by pushing analytics all the way to the DER and load assets. These local models train on individual asset data and transmit only learned parameters (such as weights) over secure communications to a global decision-maker. By abstracting personally identifiable consumer data without impacting decision optimality, this framework better aligns with distributed power generation paradigm.

Sundararajan, Aditya↗

Model-Free Dynamic Voltage Control of a Synchronous Generator-Based Microgrid

The main goal of this paper is to present a new dynamic voltage stability mechanism, based on model-free control (MFC), for effective control and coordination of synchronous generator (SG)-based reactive power resources in a microgrid setting. MFC has shown successful operation in various domains, and this paper presents its first use in the voltage stability of a power system. It is utilized as an online controller to achieve the dynamic voltage stability of a microgrid system under different disturbances and fault conditions. A 21-bus microgrid system fed by SG-based distributed energy resources (DERs) is considered as a use case study. The overall dynamic voltage stability of the microgrid system is investigated using time-domain dynamic simulations during emergency, hazard, and disaster events. Simulation results show that there are significant improvements and enhancements on the dynamic load bus voltage profiles of the microgrid system by the effective model-free control and coordination of the reactive power reserves of the SG-based DERs.

Hatipoglu, Kenan↗

Real Time Effective Impedance Estimation for Power System State Estimation

Here, we introduce two tools-the Effective Impedance State Estimator (EISE), and the Real Time Effective Impedance Estimator (RTEIE). The EISE is novel in that it is an entirely data-driven state estimator, and does not require a network model. Thus, the EISE is well suited for applications in which an accurate network model is not available. Instead of using a network impedance model, the EISE uses an effective impedance network model that is learned online by the RTEIE. The RTEIE recursively estimates the effective impedance network model using phasor measurement unit (PMU) measurements. The mathematical reasoning for using an effective impedance model, rather than a full network impedance model, is given. The recursive estimation framework allows the RTEIE to take the entire history of phasor measurements into account to produce a model estimate, while still adjusting to changes in the network impedance due to external factors such as topology changes and temperature. The merits of the RTEIE and EISE are demonstrated by comparing the accuracy of the EISE with a conventional state estimator on a toy network.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Data-Driven Democratized Control Architecture for Regional Transmission Operators

As probably the most complicated and critical infrastructure system, U.S. power grids become increasingly vulnerable to extreme events such as cyber-attacks and severe weather, as well as higher DER penetrations and growing information mismatch among system operators, utilities (transmission or generation owners), and end-users. This paper proposes a data-driven democratized control architecture considering two democratization pathways to assist transmission system operators, with a targeted use case of developing online proactive islanding strategies. Detailed discussions on load capability profiling at transmission buses and disaggregation of DER generations are provided and illustrated with real-world utility data. By Combining network and operational constraints, transmission system operators can be equipped with new tools built on top of this architecture, to derive accurate, proactive, and strategic islanding decisions to incorporate the wide range of dynamic portfolios and needs when facing extreme events or unseen grid contingencies.

Power System Reliability, Islanding, Democratized ↗

Adversarial Attacks on Deep Neural Network-based Power System Event Classification Models

Online event classification is essential to strengthening the reliability of the power transmission system. Recently, deep learning based methods have achieved great success in numerous domains such as computer vision and natural language processing. Researchers began to adopt deep learning based methods to solve the power system event identification problem and achieved effective results. However, these previous works do not consider that deep learning models are vulnerable to adversarial attacks, potentially influencing real-world applications' reliability. In this paper, we adopt several adversarial attack mechanisms by adding tailored noise signal to the input Phasor Measurement Units (PMU) time series and make the deep learning model misclassify the power system event. This numerical study discloses that current state-of-the-art deep learning based power system event classifiers are extremely vulnerable to adversarial attacks, which may jeopardize the reliability of the power transmission system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Three-Tier Incremental Approach for Development of Smart Corridor Digital Twins

Development of an arterial smart corridor digital twin requires the integration of real time data streams, data storage, and simulation model execution. This process may be complex, time consuming, and susceptible to errors. To aid in smart corridor digital twin development this paper seeks to provide a framework, best practices, and development guidance. As such, a three-tier incremental approach to smart corridor digital twin development is presented. The paper highlights practical issues in digital twin construction along with key data challenges based on experiences from the development of digital twins for two large Smart Corridor deployments, one in Chattanooga, Tennessee, and the other in Atlanta, Georgia. The presented three-tier incremental approach includes: 1) development of a prepopulated offline simulation, 2) development of a pseudo digital twin that is driven by archived data, and 3) integration of real time data streams to create the online digital twin model. The three-tiered approach facilitates conducting multiple trials and scenarios with increasing complexity, allowing for incremental error processing and updating of the digital twin.

Saroj, Abhilasha↗

A Review of Cyber-Physical Security for Photovoltaic Systems

In this paper, the challenges and a future vision of the cyber-physical security of photovoltaic (PV) systems are discussed from a firmware, network, PV converter controls, and grid security perspective. The vulnerabilities of PV systems are investigated under a variety of cyber-attacks, ranging from data integrity attacks to software-based attacks. A success rate metric is designed to evaluate the impact and facilitate decision making. Model-based and data-driven methods for threat detection and mitigation are summarized. In addition, the blockchain technology that addresses cyber-attacks in software and cyber networks is described. Simulation and experimental results that show the impact of cyber-attacks at the converter (device) and grid (system) levels are presented. Finally, potential research opportunities are discussed for next-generation, cyber-secure power electronics systems. These opportunities include multi-scale controllability, self-/event-triggering control, artificial intelligence/machine learning, hot patching, and online security. As of today, this study will be one of the few comprehensive studies in this emerging and fast-growing area.

14 SOLAR ENERGY↗

Constrained Deep Reinforcement Learning for Energy Sustainable Multi-UAV Based Random Access IoT Networks With NOMA

In this paper, we apply the Non-Orthogonal Multiple Access (NOMA) technique to improve the massive channel access of a wireless IoT network where solar-powered Unmanned Aerial Vehicles (UAVs) relay data from IoT devices to remote servers. Specifically, IoT devices contend for accessing the shared wireless channel using an adaptive p-persistent slotted Aloha protocol; and the solar-powered UAVs adopt Successive Interference Cancellation (SIC) to decode multiple received data from IoT devices to improve access efficiency. To enable an energy-sustainable capacity-optimal network, we study the joint problem of dynamic multi-UAV altitude control and multi-cell wireless channel access management of IoT devices as a stochastic control problem with multiple energy constraints. We first formulate this problem as a Constrained Markov Decision Process (CMDP), and propose an online model-free Constrained Deep Reinforcement Learning (CDRL) algorithm based on Lagrangian primal-dual policy optimization to solve the CMDP. Extensive simulations demonstrate that our proposed algorithm learns a cooperative policy in which the altitude of UAVs and channel access probability of IoT devices are dynamically controlled to attain the maximal long-term network capacity while ensuring energy sustainability of UAVs, outperforming baseline schemes. The proposed CDRL agent can be trained on a small network, yet the learned policy can efficiently manage networks with a massive number of IoT devices and varying initial states, which can amortize the cost of training the CDRL agent.

42 ENGINEERING↗

Optimal Power Flow With State Estimation in the Loop for Distribution Networks

Here in this article, we propose a framework for running optimal control-estimation synthesis in distribution networks. Our approach combines a primal-dual gradient-based optimal power flow solver with a state estimation feedback loop based on a limited set of sensors for system monitoring, instead of assuming exact knowledge of all states. The estimation algorithm reduces uncertainty on unmeasured grid states based on certain online state measurements and noisy "pseudomeasurements." We analyze the convergence of the proposed algorithm and quantify the statistical estimation errors based on a weighted least-squares estimator. The numerical results on a 4521-node network demonstrate that this approach can scale to extremely large networks and provide robustness to both large pseudomeasurement variability and inherent sensor measurement noise.

24 POWER TRANSMISSION AND DISTRIBUTION↗