Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

The ICARE Method

The ICARE method is a flexible, widely applicable method for systems engineers to solve problems and resolve issues in a complete and comprehensive manner. The method can be tailored by diverse users for direct application to their function (e.g. system integrators, design engineers, technical discipline leads, analysts, etc.). The clever acronym, ICARE, instills the attitude of accountability, safety, technical rigor and engagement in the problem resolution: Identify, Communicate, Assess, Report, Execute (ICARE). This method was developed through observation of Space Shuttle Propulsion Systems Engineering and Integration (PSE&I) office personnel approach in an attempt to succinctly describe the actions of an effective systems engineer. Additionally it evolved from an effort to make a broadly-defined checklist for a PSE&I worker to perform their responsibilities in an iterative and recursive manner. The National Aeronautics and Space Administration (NASA) Systems Engineering Handbook states, engineering of NASA systems requires a systematic and disciplined set of processes that are applied recursively and iteratively for the design, development, operation, maintenance, and closeout of systems throughout the life cycle of the programs and projects. ICARE is a method that can be applied within the boundaries and requirements of NASA s systems engineering set of processes to provide an elevated sense of duty and responsibility to crew and vehicle safety. The importance of a disciplined set of processes and a safety-conscious mindset increases with the complexity of the system. Moreover, the larger the system and the larger the workforce, the more important it is to encourage the usage of the ICARE method as widely as possible. According to the NASA Systems Engineering Handbook, elements of a system can include people, hardware, software, facilities, policies and documents; all things required to produce system-level results, qualities, properties, characteristics, functions, behavior and performance. The ICARE method can be used to improve all elements of a system and, consequently, the system-level functional, physical and operational performance. Even though ICARE was specifically designed for a systems engineer, any person whose job is to examine another person, product, or process can use the ICARE method to improve effectiveness, implementation, usefulness, value, capability, efficiency, integration, design, and/or marketability. This paper provides the details of the ICARE method, emphasizing the method s application to systems engineering. In addition, a sample of other, non-systems engineering applications are briefly discussed to demonstrate how ICARE can be tailored to a variety of diverse jobs (from project management to parenting).

Henke, Luke↗

Improved Method of Locating Defects in Wiring Insulation

An improved method of locating small breaches in insulation on electrical wires combines aspects of the prior dielectric withstand voltage (DWV) and time-domain reflectometry (TDR) methods. The method was invented to satisfy a need for reliably and quickly locating insulation defects in spacecraft, aircraft, ships, and other complex systems that contain large amounts of wiring, much of it enclosed in structures that make it difficult to inspect. In the DWV method, one applies a predetermined potential (usually 1.5 kV DC) to the wiring and notes whether the voltage causes any arcing between the wiring and ground. The DWV method does not provide an indication of the location of the defect (unless, in an exceptional case, the arc happens to be visible). In addition, if there is no electrically conductive component at ground potential within about 0.010 in. (approximately equal to 0.254 mm) of the wire at the location of an insulation defect, then the DWV method does not provide an indication of the defect. Moreover, one does not have the option to raise the potential in an effort to increase the detectability of such a defect because doing so can harm previously undamaged insulation. In the TDR method as practiced heretofore, one applies a pulse of electricity having an amplitude of less than 25 V to a wire and measures the round-trip travel time for the reflection of the pulse from a defect. The distance along the wire from the point of application of the pulse to the defect is then calculated as the product of half the round-trip travel time and the characteristic speed of a propagation of an electromagnetic signal in the wire. While the TDR method as practiced heretofore can be used to locate a short or open circuit, it does not ordinarily enable one to locate a small breach in insulation because the pulse voltage is too low to cause arcing and thus too low to induce an impedance discontinuity large enough to generate a measurable reflection. The present improved method overcomes the weaknesses of both the prior DWV and the prior TDR method.

Greulich, Owen R.↗

Diagonally Implicit Runge-Kutta Methods for Ordinary Differential Equations. A Review

A review of diagonally implicit Runge-Kutta (DIRK) methods applied to rst-order ordinary di erential equations (ODEs) is undertaken. The goal of this review is to summarize the characteristics, assess the potential, and then design several nearly optimal, general purpose, DIRK-type methods. Over 20 important aspects of DIRKtype methods are reviewed. A design study is then conducted on DIRK-type methods having from two to seven implicit stages. From this, 15 schemes are selected for general purpose application. Testing of the 15 chosen methods is done on three singular perturbation problems. Based on the review of method characteristics, these methods focus on having a stage order of two, sti accuracy, L-stability, high quality embedded and dense-output methods, small magnitudes of the algebraic stability matrix eigenvalues, small values of aii, and small or vanishing values of the internal stability function for large eigenvalues of the Jacobian. Among the 15 new methods, ESDIRK4(3)6L[2]SA is recommended as a good default method for solving sti problems at moderate error tolerances.

Kennedy, Christopher A.↗

A METHOD TO REDUCE BIOBURDEN IN ASTROMATERIALS CURATION FACILITIES WITHOUT INTRODUCING UNWANTED CONTAMINATION

Introduction: NASA curates its Astromaterials collections in cleanrooms that are carefully monitored for particulate, inorganic and trace metal contamination. Current sample collections are not particularly susceptible to organic contamination or biological alteration. However, new collections like those from the OSIRIS-REx and Hayabusa2 missions will have organic contamination requirements and are susceptible to biodegradation. It will be necessary sterilize or at least disinfect curation labs, as well as tools and equipment in a manner that does not introduce additional contamination and does not affect the samples 1. Current curation cleaning procedures utilize isopropyl alcohol which offers some bioburden reduction, but is not effective against spore-forming bacteria or fungal spores 2. We present a modified disinfection method that uses ultrapure hydrogen peroxide to reduce bioburden inside curation labs and glove boxes without introducing contamination or damaging curation equipment. We tested this method in the meteorite processing lab as well as on a glovebox being cleaned for use in processing ANGSA (Apollo Next Generation Sample Analysis) samples and present the results of those tests. We discuss the limitations of this method and describe potential situations in which it will not be applicable. The CDC guidelines for disinfection andsterilization in healthcare facilities discusses over 15different methods for reducing bioburden in hospitalsettings 3. The most common method, steamsterilization, is well suited to sterilizing curationprocessing tools but cannot easily be used to sterilizecleanroom surfaces or large equipment likegloveboxes. Chemical sterilization with bleach(NaOCl) is also a common strategy in healthcare andpharmaceutical settings that presents materialcompatibility issues as well as serious inorganiccontamination concerns for curation facilities.Introducing a new source of Na and Cl into curationlabs is not acceptable. Other chemical methods likeethylene oxide, formaldehyde, iodophors andquaternary ammonium compounds could introduceorganic and inorganic contamination. We chose tofocus on hydrogen peroxide because it is generallycompatible with commonly used curation materialslike stainless steel, aluminum and Teflon and becauseit decomposes to oxygen and water. The CDCguidelines for hydrogen peroxide specify using a 7.5wt% solution at 25 ̊C with a contact time of 30 minutesfor high level disinfection and 6 hours for sterilization.High level disinfection is defined as a technique thatwill kill all microorganisms except large numbers ofbacterial spores 3. Methods: We prepared a solution of 7.5 wt%hydrogen peroxide from a stock solution of ultrapure30 wt% peroxide (JT Baker) and curation gradeultrapure water. This ultrapure water is already used incuration cleaning procedures and thus is not consideredand additional source of contamination. We conducteda materials compatibility test by exposing unanodizedand anodized 6061 T6 Al alloy to the peroxide solutionfor up to six hours and periodically inspecting thesurfaces for visible defects. We used this peroxide todisinfect the floor of the meteorite processing lab andthe interior of a curation glovebox by exposing thesesurfaces to the peroxide solution for 30 min. Thesurfaces were swabbed with a dry macrofoam swabbefore (Puritan Brand 2518051PFRNDFD) and afterperoxide treatment to collect microbes present on thesurfaces. Microbes were extracted by sonication fromthe swab into 15 ml of PBS (phosphate buffered saline)and inoculated onto the following media: TSA (trypticsoy agar) BA (blood agar), R2A (Reasoners 2 agar),Potato Dextrose Agar, Saboraud Dextrose Agar andSaboraud Dextrose Agar with 0.1 mg/ mlchloramphenicol. Four TSA plates and two BA plateswere inoculated with 0.1 ml of PBS each andincubated at 35 and 37 for 48 hours. Two R2A°C°Cplates (0.1 ml of PBS each) were incubated at 25 .°CThe remaining plates were inoculated with 0.2ml ofPBS and incubated at 30 ̊C for seven days. Afterincubation bacterial and fungal isolates were countedand transferred to new plates for identification usingthe VITEK24 automated system or by sequencing aportion of the barcode gene (16S rRNA for bacteria,small subunit gene for fungi) on an ABI 3500 Sangersequencer. Negative controls consisted of swabs thatwere opened in the sampling environment andanalyzed alongside the experimental samples.Results: A 6 hour exposure to hydrogen peroxideresulted in visible pitting on un-anodized 6061 Al, butnot on anodized surfaces. No visible pitting occurredafter a 30 minute exposure. Therefore, we decided tolimit our experimental tests to 30 min. exposures. 17bacterial CFU (colony forming units) representing 4distinct organisms were isolated from the meteorite processing lab floor prior to hydrogen peroxidetreatment. We were unable culture any organisms afterperoxide treatment. In the glovebox we were able toculture three bacterial CFU representing three distinctspecies, including a spore forming bacterium prior todisinfection with peroxide. After the peroxidetreatment we were unable to culture any organisms.Routine monitoring of the meteorite processing lab andthe glovebox did not indicate any increase in unwantedinorganic contamination after these peroxidetreatments. Discussion: A 30 minute treatment with 7.5 wt%peroxide appears to be an effective method forreducing bioburden on typical cleanroom surfaces. Themethod does not introduce unwanted organic orinorganic contamination and is compatible withcommonly used curation materials like stainless steel,Teflon and anodized aluminum alloys. Special careshould be taken with un-anodized aluminum.Prolonged exposure to hydrogen peroxide can causepitting on this material. We recommend using thismethod to disinfect curation labs and equipment whenbiological alteration is a concern. This method iseffective at room temperature and cannot be used todisinfect labs and equipment where the ambienttemperature is < 0 ̊C. Astromaterials samples shouldbe removed from the area where disinfection is tooccur. Hydrogen peroxide is a powerful oxidizingagent and will react with any organic carbon present inthe sample. References: [1.] Mccubbin, F. M. et al.Sp. Sci Rev(2019) doi:10.1007/s11214-019-0615-9. [2.] Mogul, R.et al.Astrobiology 18, ast.2017.1814 (2018). [3.]Rutala, W. A. & Weber, D. J. Guideline for Disinfection and Sterilization in Healthcare Facilities, 2008. [4.] Pincus, D. H. in Encyclopedia of Rapid Microbiological Methods (2005).

A. B. Regberg↗

TOWARD A METHOD FOR SCALING HUMAN BODY MODELS IN AN IMU-BASED WORKFLOW

BACKGROUND Scaled biomechanical models can more accurately inform crew health decisions when tailored to the wide range of astronaut sizes. One component to improve scaling of existing models to better represent each unique astronaut’s size is the individual length scaling of limbs. Traditionally, these lengths are determined by motion capture or manual measurement. A new method is herein proposed for length scaling which can be done by measuring linear and angular accelerations at a desired point during isolated motion around a point of rotation, then calculating the distance between the desired point and point of rotation. When an Inertial Measurement Unit (IMU) device is placed at the distal point of a limb, the isolated motion is about that limb’s proximal joint. For example, to measure forearm length, an IMU is placed at the wrist, the point of rotation is at the elbow, and the isolated motion is forearm flexion and extension. These calculated lengths are then used to scale models to each unique astronaut’s size, thereby improving the applicability of the model. This method of scaling limb segments can be used for any limb that has an easily defined proximal joint for the limb to rotate around including hands, arms, legs, feet. Utilizing IMUs for data collection also provides the synergistic ability to record data without a dedicated space in a room with many cameras, therefore reducing the data collection footprint, or record data where optical motion capture is not possible, such as inside a spacesuit. METHODS AND RESULTS To test this method, upper body data collection was performed with 5 Xsens DOT IMUs on a single subject. IMUs consist of an accelerometer, a gyroscope, and a magnetometer which collect linear acceleration, angular velocity, and magnetic fluctuations, respectively. Before any ground-based laboratory collection, the magnetic fluctuations are used to correct the heading of the IMU in space relative to the Earth’s magnetic field. The direct measurement of angular velocity is integrated to calculate angular acceleration. Then the linear acceleration ( a ) and angular acceleration (α) are solved using r = at/α to calculate the radius, which in this case is the distance between the IMU and the point of rotation (i.e., segment length). The IMU must be placed at the most distal point of the limb being measured (i.e., ankle if measuring lower leg length) and the test plan must consist of an isolated motion about that limb’s proximal joint (i.e., knee flexion and extension if measuring lower leg length). The distances (radii) calculated at every time interval were filtered (bandpass filter keeping 5th-90th percentile data) to eliminate outliers and spurious data that occur when the isolated motion was stopped or nearly stopped. The remaining distances were averaged, resulting in the calculated limb length. Scaling factors were then computed by dividing the calculated limb length by the unscaled model’s length. These scale factors are plugged into the Scale Tool in OpenSim [1,2] to apply the scaling to the OpenSim Full Body Rajagopal Model [3,4]. Manual measurements of limb lengths were taken before data collection started and used for comparing against the calculated lengths. The Anthropometric Survey of US Army Personnel (ANSUR II) [5] was also used as a third source of reference for limb length measurements. The following measurements were retrieved from the subject before data collection: 34.5 cm from L1 to C7 (thorax), 25.7 cm from C7 Joint Center (JC) to head vertex (neck and head), 36.3 cm from shoulder JC to elbow JC (humerus), 29.5 cm from elbow JC to wrist JC (forearm), and 16.2 cm from clavicle to acromion (clavicle). Of those five, forearm and humerus lengths were calculated using this proposed method to obtain preliminary results. The forearm length after filtering and averaging was calculated to be 37.6 cm. This is a 28% overestimation from the measured forearm length (29.5 cm). The humerus length after filtering and averaging was calculated to be 47.8 cm. This is a 31% difference from the measured subject length (36.3 cm). Sources of error include imperfect isolated motion (method currently expects that motion should be perfectly circular in a 2D plane, include no rotation of the IMU, and be relatively smooth; a more secure IMU attachment method will help), unrefined filter techniques (removed highest and lowest values with 20% high and low pass filters and no smoothing filters), arbitrary removal of stopped or near stopped data (kept data for only a short range before and after the angular velocity peaking), and a more representative method for removing gravitational acceleration is needed (current method is to zero all accelerations against a baseline taken just before the isolated motion which does not account for the gravitational acceleration changed due to IMU rotation during movement). Addressing these error sources will improve the accuracy of the limb length calculation. Next steps include creating a method for whole-body scaling estimation using individual limb scale factors. Continued pursuit of these techniques is expected to enable acquiring anthropometric information using only IMUs in real-time.

E. K. Marecki↗

Efficient algorithm for generating spectra using line-by-lne methods

A method is presented for efficient generation of spectra using line-by-line approaches. The only approximation is replacing the line shape function with an interpolation procedure, which makes the method independent of the line profile functional form. The resulting computational savings for large number of lines is proportional to the number of frequency points in the spectral range. Therefore, for large-scale problems the method can provide speedups of two orders of magnitude or more. A method was presented to generate line-by-line spectra efficiently. The first step was to replace the explicit calculation of the profile by the Newton divided-differences interpolating polynomial. The second step is to accumulate the lines effectively reducing their number to the number of frequency points. The final step is recognizing the resulting expression as a convolution and amenable to FFT methods. The reduction in computational effort for a configuration-to-configuration transition array with large number of lines is proportional to the number of frequency points. The method involves no approximations except for replacing the explicit profile evaluation by interpolation. Specifically, the line accumulation and convolution are exact given the interpolation procedure. Furthermore, the interpolation makes the method independent of the line profile functional form contrary to other schemes using FFT methods to generate line-by-line spectra but relying on the analytic form of the profile Fourier transform. Finally, the method relies on a uniform frequency mesh. For non-uniform frequency meshes, however, the method can be applied by using a suitable temporary uniform mesh and the results interpolated onto the final mesh with little additional cost.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Comparative Study of Different Reconstruction Schemes for a Reconstructed Discontinuous Galerkin Method on Arbitrary Grids

A comparative study of different reconstruction schemes for a reconstruction-based discontinuous Galerkin, termed RDG(P1P2) method is performed for compressible flow problems on arbitrary grids. The RDG method is designed to enhance the accuracy of the discontinuous Galerkin method by increasing the order of the underlying polynomial solution via a reconstruction scheme commonly used in the finite volume method. Both Green-Gauss and least-squares reconstruction methods and a least-squares recovery method are implemented to obtain a quadratic polynomial representation of the underlying discontinuous Galerkin linear polynomial solution on each cell. These three reconstruction/recovery methods are compared for a variety of compressible flow problems on arbitrary meshes to access their accuracy and robustness. The numerical results demonstrate that all three reconstruction methods can significantly improve the accuracy of the underlying second-order DG method, although the least-squares reconstruction method provides the best performance in terms of both accuracy and robustness.

97 MATHEMATICS AND COMPUTING↗

Efficient iterative method for solving the Dirac-Kohn-Sham density functional theory

We present for the first time an efficient iterative method to directly solve the four-component Dirac-Kohn-Sham (DKS) density functional theory. Due to the existence of the negative energy continuum in the DKS operator, the existing iterative techniques for solving the Kohn-Sham systems cannot be efficiently applied to solve the DKS systems. The key component of our method is a novel filtering step (F) which acts as a preconditioner in the framework of the locally optimal block preconditioned conjugate gradient (LOBPCG) method. The resulting method, dubbed the LOBPCG-F method, is able to compute the desired eigenvalues and eigenvectors in the positive energy band without computing any state in the negative energy band. The LOBPCG-F method introduces mild extra cost compared to the standard LOBPCG method and can be easily implemented. We demonstrate our method in the pseudopotential framework with a planewave basis set which naturally satisfies the kinetic balance prescription. Numerical results for Pt$_{2}$, Au$_{2}$, TlF, and Bi$_{2}$Se$_{3}$ indicate that the LOBPCG-F method is a robust and efficient method for investigating the relativistic effect in systems containing heavy elements.

74 ATOMIC AND MOLECULAR PHYSICS↗

Treatment of Nonuniform Temperature Distribution by Subgroup Method

The subgroup method divides an energy group into several subgroups according to the magnitude of the cross section. The subgroup fixed source equation is formulated on the energy range of a subgroup, the ratio of which to the energy range of an energy group is defined as subgroup probability. Typically the physical probability table or the mathematical probability table is applied. However, both of the tables are not guaranteed to share the same set of subgroup probabilities for a resonant nuclide at different temperatures. This means that the subgroup fixed source equation cannot be formulated and the subgroup method will not work when the temperature distribution is nonuniform. To overcome this defect, the subgroup method based on partial cross section fit scheme (PXSFS) and the simplified partial cross section fit scheme (SPXSFS) are proposed. These methods fit the cross sections at different temperatures as partial cross sections to share a same set of subgroup probabilities. The new methods is compared to the conventional subgroup method (CSM) based on physical probability table and the preexisting methods: the correlation model (CM), the subgroup level adjustment scheme (SLAS) and the number density adjustment scheme (NDAS). The numerical results show that the new methods can better predict the spatial dependent reaction rate than preexisting methods. Within these two methods, the simplified scheme consumes less time.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Sweepless time-dependent transport calculations using the staggered block Jacobi method

The Staggered-Block Jacobi (SBJ) method is a new numerical SN transport method for solving time-dependent problems without sweeps or low-order acceleration. Because it is a Jacobian method, it is trivial to parallelize and will scale linearly with the number of processors, It is highly accurate in thick-diffusive problems and unconditionally stable when combined with the lumped linear discontinuous finite element spatial discretization. In this way, the SBJ method is complementary to sweep-based methods, which are accurate and efficient in thin, streaming regions but inefficient in thick, diffusive problems without acceleration. We have extended previous work by demonstrating how sweep-based methods and the SBJ method may be combined to produce a method which is accurate and efficient without acceleration in all optical thicknesses while still retaining good parallel efficiency. Furthermore, iterations may also be added to the SBJ method. This is particularly useful for improving the accuracy of the SBJ method in intermediate-thickness problems.

97 MATHEMATICS AND COMPUTING↗

Fast iterative refinement method for mixed systems of integral and fractional integro-differential equations

The authors’ new method of iterative refinement has been successfully applied to the linear fractional Fredholm integro-differential equation. In this work, we adapt our method to obtain approximate analytical solutions for linear Volterra equations of both the first and the second kind of fractional type. A detailed convergence analysis is presented for each kind. The authors also apply their method to the challenging first kind linear Fredholm integral equation. Three different cases are considered to test the efficacy of our method. These include mixed systems of various forms of linear integral and fractional integro-differential equations. We compare our method with six well-established methods: Picard’s successive approximations, an accelerated form of the latter, the Adomian decomposition, the variational iteration, the homotopy perturbation and the homotopy analysis. The results show the versatility of the new method in solving a wide variety of equations, its high convergence speed and accuracy and its capability of directly dealing with equations of the first kind. We also prove that Picard’s method for linear equations is a special case of our method.

97 MATHEMATICS AND COMPUTING↗

A reverse Monte Carlo method for deriving optical constants of solids from reflection electron energy-loss spectroscopy spectra

A reverse Monte Carlo (RMC) method is developed to obtain the energy loss function (ELF) and optical constants from a measured reflection electron energy-loss spectroscopy (REELS) spectrum by an iterative Monte Carlo (MC) simulation procedure. The method combines the simulated annealing method, i.e., a Markov chain Monte Carlo (MCMC) sampling of oscillator parameters, surface and bulk excitation weighting factors, and band gap energy, with a conventional MC simulation of electron interaction with solids, which acts as a single step of MCMC sampling in this RMC method. To examine the reliability of this method, we have verified that the output data of the dielectric function are essentially independent of the initial values of the trial parameters, which is a basic property of a MCMC method. The optical constants derived for SiO{sub 2} in the energy loss range of 8-90 eV are in good agreement with other available data, and relevant bulk ELFs are checked by oscillator strength-sum and perfect-screening-sum rules. Our results show that the dielectric function can be obtained by the RMC method even with a wide range of initial trial parameters. The RMC method is thus a general and effective method for determining the optical properties of solids from REELS measurements.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

TU-CD-BRA-12: Coupling PET Image Restoration and Segmentation Using Variational Method with Multiple Regularizations

Purpose: To propose a new variational method which couples image restoration with tumor segmentation for PET images using multiple regularizations. Methods: Partial volume effect (PVE) is a major degrading factor impacting tumor segmentation accuracy in PET imaging. The existing segmentation methods usually need to take prior calibrations to compensate PVE and they are highly system-dependent. Taking into account that image restoration and segmentation can promote each other and they are tightly coupled, we proposed a variational method to solve the two problems together. Our method integrated total variation (TV) semi-blind deconvolution and Mumford-Shah (MS) segmentation. The TV norm was used on edges to protect the edge information, and the L{sub 2} norm was used to avoid staircase effect in the no-edge area. The blur kernel was constrained to the Gaussian model parameterized by its variance and we assumed that the variances in the X-Y and Z directions are different. The energy functional was iteratively optimized by an alternate minimization algorithm. Segmentation performance was tested on eleven patients with non-Hodgkin’s lymphoma, and evaluated by Dice similarity index (DSI) and classification error (CE). For comparison, seven other widely used methods were also tested and evaluated. Results: The combination of TV and L{sub 2} regularizations effectively improved the segmentation accuracy. The average DSI increased by around 0.1 than using either the TV or the L{sub 2} norm. The proposed method was obviously superior to other tested methods. It has an average DSI and CE of 0.80 and 0.41, while the FCM method — the second best one — has only an average DSI and CE of 0.66 and 0.64. Conclusion: Coupling image restoration and segmentation can handle PVE and thus improves tumor segmentation accuracy in PET. Alternate use of TV and L2 regularizations can further improve the performance of the algorithm. This work was supported in part by National Natural Science Foundation of China (NNSFC), under Grant No.61375018, and Fundamental Research Funds for the Central Universities, under Grant No. 2012QN086. Wei Lu was supported in part by the National Institutes of Health (NIH) Grant No. R01 CA172638.

60 APPLIED LIFE SCIENCES↗

Atomistic hybrid DSMC/NEMD method for nonequilibrium multiscale simulations

A multiscale hybrid method for coupling the direct simulation Monte Carlo (DSMC) method to the nonequilibrium molecular dynamics (NEMD) method is introduced. The method addresses Knudsen layer type gas flows within a few mean free paths of an interface or about an object with dimensions of the order of a few mean free paths. It employs the NEMD method to resolve nanoscale phenomena closest to the interface along with coupled DSMC simulation of the remainder of the Knudsen layer. The hybrid DSMC/NEMD method is a particle based algorithm without a buffer zone. It incorporates a new, modified generalized soft sphere (MGSS) molecular collision model to improve the poor computational efficiency of the traditional generalized soft sphere GSS model and to achieve DSMC compatibility with Lennard-Jones NEMD molecular interactions. An equilibrium gas, a Fourier thermal flow, and an oscillatory Couette flow, are simulated to validate the method. The method shows good agreement with Maxwell-Boltzmann theory for the equilibrium system, Chapman-Enskog theory for Fourier flow, and pure DSMC simulations for oscillatory Couette flow. Speedup in CPU time of the hybrid solver is benchmarked against a pure NEMD solver baseline for different system sizes and solver domain partitions. Finally, the hybrid method is applied to investigate interaction of argon gas with solid surface molecules in a parametric study of the influence of wetting effects and solid molecular mass on energy transfer and thermal accommodation coefficients. It is determined that wetting effect strength and solid molecular mass have a significant impact on the energy transfer between gas and solid phases and thermal accommodation coefficient.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Impact of hydrogen SAE J2601 fueling methods on fueling time of light-duty fuel cell electric vehicles

Hydrogen fuel cell electric vehicles (HFCEVs) are zero-emission vehicles (ZEVs) that can provide drivers a similar experience to conventional internal combustion engine vehicles (ICEVs), in terms of fueling time and performance (i.e. power and driving range). The Society of Automotive Engineers (SAE) developed fueling protocol J2601 for light-duty HFCEVs to ensure safe vehicle fills while maximizing fueling performance. This study employs a physical model that simulates and compares the fueling performance of two fueling methods, known as the “lookup table” method and the “MC formula” method, within the SAE J2601 protocol. Both the fueling methods provide fast fueling of HFCEVs within minutes, but the MC formula method takes advantage of active measurement of precooling temperature to dynamically control the fueling process, and thereby provides faster vehicle fills. Here, the MC formula method greatly reduces fueling time compared to the lookup table method at higher ambient temperatures, as well as when the precooling temperature falls on the colder side of the expected temperature window for all station types. Although the SAE J2601 lookup table method is the currently implemented standard for refueling hydrogen fuel cell vehicles, the MC formula method provides significant fueling time advantages in certain conditions; these warrant its implementation in future hydrogen refueling stations for better customer satisfaction with fueling experience of HFCEVs.

13 HYDRO ENERGY↗

A verification study of fatigue-based methods in API RP 1183 for estimating fatigue life of pipeline dents

Pipeline dents are mechanical damage caused by a third party in buried pipelines during construction or maintenance repair. Dents are recognized as a leading cause of pipeline failures for both liquid and gas transmission lines, and their assessment and management are critical to pipeline integrity. To meet the industry need, American Institute of Petroleum (API) in 2020 published a recommended practice (RP) 1183 – Assessment and Management of Pipeline Dents. This API code provides the pipeline industry “standard methods” for evaluating severity and fatigue life of pipeline dents with a single peak. This paper performed an initial verification study of fatigue-based methods prescribed in API RP 1183 for estimating fatigue life of pipeline dents. A brief review was first given to the dent fatigue-based methods, including three dent screening methods for estimating dent fatigue life in Sections 7.4.1, 7.4.2, and 7.4.3 of API 1183 and one dent assessment method for predicting fatigue life in Section 8.3.4. In order to verify these fatigue life prediction methods, a set of “standard examples” of dents provided in Annexes A.1 to A.5 of API RP 1183 were utilized in this study to calculate fatigue life, to determine restraint condition, and to evaluate both screening and assessment methods for single-peak dents. Through detailed calculations and comparisons, this study confirmed some specifications of API RP 1183, but also found some self-inconsistences and errors existing in this new API code. Furthermore, this includes the self-inconsistences between three screening methods and the self-inconsistence between the screening and assessment methods. On this basis, recommendations were made on how the operators should use API RP 1183, and what actions API should take to improve this code.

42 ENGINEERING↗

A hybrid Boundary Element Unstructured Transmission-line (BEUT) method for accurate 2D electromagnetic simulation

Time domain electromagnetic simulation tools have the ability to model transient, wide-band applications, and non-linear problems. The Boundary Element Method (BEM) and the Transmission Line Modeling (TLM) method are both well established numerical techniques for simulating time-varying electromagnetic fields. The former surface based method can accurately describe outwardly radiating fields from piecewise uniform objects and efficiently deals with large domains filled with homogeneous media. The latter volume based method can describe inhomogeneous and non-linear media and has been proven to be unconditionally stable. Furthermore, the Unstructured TLM (UTLM) enables modelling of geometrically complex objects by using triangular meshes which removes staircasing and unnecessary extensions of the simulation domain. The hybridization of BEM and UTLM which is described in this paper is named the Boundary Element Unstructured Transmission-line (BEUT) method. It incorporates the advantages of both methods. The theory and derivation of the 2D BEUT method is described in this paper, along with any relevant implementation details. The method is corroborated by studying its correctness and efficiency compared to the traditional UTLM method when applied to complex problems such as the transmission through a system of Luneburg lenses and the modelling of antenna radomes for use in wireless communications. - Graphical abstract:.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An Immersed Boundary method with divergence-free velocity interpolation and force spreading

The Immersed Boundary (IB) method is a mathematical framework for constructing robust numerical methods to study fluid–structure interaction in problems involving an elastic structure immersed in a viscous fluid. The IB formulation uses an Eulerian representation of the fluid and a Lagrangian representation of the structure. The Lagrangian and Eulerian frames are coupled by integral transforms with delta function kernels. The discretized IB equations use approximations to these transforms with regularized delta function kernels to interpolate the fluid velocity to the structure, and to spread structural forces to the fluid. It is well-known that the conventional IB method can suffer from poor volume conservation since the interpolated Lagrangian velocity field is not generally divergence-free, and so this can cause spurious volume changes. In practice, the lack of volume conservation is especially pronounced for cases where there are large pressure differences across thin structural boundaries. The aim of this paper is to greatly reduce the volume error of the IB method by introducing velocity-interpolation and force-spreading schemes with the properties that the interpolated velocity field in which the structure moves is at least $\mathscr{C}$ 1 and satisfies a continuous divergence-free condition, and that the force-spreading operator is the adjoint of the velocity-interpolation operator. We confirm through numerical experiments in two and three spatial dimensions that this new IB method is able to achieve substantial improvement in volume conservation compared to other existing IB methods, at the expense of a modest increase in the computational cost. Further, the new method provides smoother Lagrangian forces (tractions) than traditional IB methods. Finally, the method presented here is restricted to periodic computational domains. Its generalization to non-periodic domains is important future work.

97 MATHEMATICS AND COMPUTING↗