Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “loading”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Effect of Loading Rate and Surface Conditions on Flexural Strength of Borosilicate Glass

This study evaluates the loading rate and surface condition dependence of the flexural strength of a borosilicate glass. The glass specimens are subjected to three different surface treatments before four-point bending tests to study the effect of surface flaws. Quasistatic (Material Test System 810) and dynamic (Kolsky bar) experiments are performed at loading rates ranging from 0.7 to 4 x 10{sup 6} MPa/s. The results show that the flexural strength of the borosilicate glass has a strong dependence on the loading rate. A chemically etched surface produces an enhanced flexural strength by about an order of magnitude. Scanning electron microscopy images on fracture surfaces indicate that the failure is governed by different types of flaws under different surface treatment conditions. Edge failure is also identified for samples possessing high flexural strength.

36 MATERIALS SCIENCE↗

Simulation-Length Requirements in the Loads Analysis of Offshore Floating Wind Turbines: Preprint

The goal of this paper is to examine the appropriate length of a floating offshore wind turbine (FOWT) simulation - a fundamental question that needs to be answered to develop design requirements. To examine this issue, a loads analysis of an example FOWT was performed in FAST with varying simulation lengths. The offshore wind system used was the OC3-Hywind spar buoy, which was developed for use in the International Energy Agency Code Comparison Collaborative Project and supports NREL's offshore 5-megawatt baseline turbine. Realistic metocean data from the National Oceanic and Atmospheric Administration and repeated periodic wind files were used to excite the structure. The results of the analysis clearly show that loads do not increase for longer simulations. In regards to fatigue, a sensitivity analysis shows that the procedure used for counting half cycles is more important than the simulation length itself. Based on these results, neither the simulation length nor the periodic wind files affect response statistics and loads for FOWTs (at least for the spar studied here); a result in contrast to the offshore oil and gas industry, where running simulations of at least 3 hours in length is common practice.

17 WIND ENERGY↗

Results of high heat flux tests of tungsten divertor targets under plasma heat loads expected in ITER and tokamaks (review)

Heat loads on the tungsten divertor targets in the ITER and the tokamak power reactors reach ~10MW m{sup −2} in the steady state of DT discharges, increasing to ~0.6–3.5 GW m{sup −2} under disruptions and ELMs. The results of high heat flux tests (HHFTs) of tungsten under such transient plasma heat loads are reviewed in the paper. The main attention is paid to description of the surface microstructure, recrystallization, and the morphology of the cracks on the target. Effects of melting, cracking of tungsten, drop erosion of the surface, and formation of corrugated and porous layers are observed. Production of submicron-sized tungsten dust and the effects of the inhomogeneous surface of tungsten on the plasma–wall interaction are discussed. In conclusion, the necessity of further HHFTs and investigations of the durability of tungsten under high pulsed plasma loads on the ITER divertor plates, including disruptions and ELMs, is stressed.

36 MATERIALS SCIENCE↗

Investigating the performance of catalyst layer micro-structures with different platinum loadings

In this study a four-phase micro-structure of a PEFC catalyst layer was reconstructed by randomly placing overlapping spheres for each solid catalyst phase. The micro-structure was mirrored to make a micro-structure. A body-fit computational mesh was produced for the reconstructed micro-structure in OpenFOAM. Associated conservation equations were solved within all the phases with electrochemical reaction as the boundary condition at the interface between ionomer and platinum phases. The study is focused on the platinum loading of CL. The polarization curves of the micro-structure performance have been compared for different platinum loadings. This paper gives increased insight into the relatively greater losses at decreased platinum loadings.

08 HYDROGEN↗

Microstructural Analysis and Transport Resistances of Low-Platinum-Loaded PEFC Electrodes

In this study, we present microstructural characterization for polymer electrolyte fuel cell (PEFC) cathodes with low platinum loadings (low-PGM). The characterization results are used to quantify the contribution of mass transport resistances to cell voltage losses observed in polarization curve data. Three-dimensional pore morphology and ionomer distribution are resolved using nano-scale X-ray computed tomography (nano-CT). Electrode structural properties are reported along with analysis of the impact of microstructure on the effective charge and reactant transport properties. These characterizations are incorporated with a two-dimensional multi-physics model that accounts for energy, charge, and mass transport along with the effect of liquid water flooding. Defining a total mass transport resistance for the whole polarization curve, contributions of transport mechanisms are identified. Analysis of the experimental polarization curves at different operating pressures and temperatures indicates that the mass transport resistance in the cathode is dominated by the transport processes in the electrode. It is shown that flooding in the electrode is a major contributor to transport losses especially at elevated operating pressures while the pressure-independent resistance at the catalyst surface due to transport through the ionomer film plays a significant role, especially at low temperatures and low catalyst loading. In addition, by performing a parametric study for varying catalyst loadings, the importance of electrode roughness (i.e, electrochemically-active surface area/geometric electrode area) in determining the mass transport losses is highlighted.

25 ENERGY STORAGE↗

Community Geothermal: Soil Conductivity, Borehole Design, Energy Models, and Load Data for a Residential System Development - Hinesburg, VT

This dataset contains materials from the Coalition for Community-Supported Affordable Geothermal Energy Systems (C2SAGES) project, which evaluated the techno-economic feasibility of a community geothermal system for a residential development in Hinesburg, VT. The dataset includes detailed soil conductivity test reports, energy models, borehole design reports, hourly energy loads for heating, cooling, and hot water, and design layouts. EnergyPlus was used to model building energy loads, and Modelica software was applied for geothermal loop sizing based on these loads and soil conductivity results. Python scripts for network design further refined the models. Key files include PDF reports on borehole design (with projections for 1-year, 15-year, and 30-year systems), soil conductivity test results, EnergyPlus modeling outputs, and 2D/3D design drawings in PDF, DWG, and DXF formats. Python notebooks for network design and OnePipe model files are also provided, with Modelica required for viewing certain files. Outputs and modeling data are in various formats including CSV, JPG, HTML, and IDF, with units and data clearly labeled to support understanding of system design and performance for the proposed geothermal solution.

15 GEOTHERMAL ENERGY↗

Commercial and Residential Hourly Load Profiles for All Typical Meteorological Year 3 (TMY3) Locations in the United States

One way to achieve grid flexibility is to shed or shift demand to align with changing grid needs. To facilitate this, it is critical to understand how and when energy is used. High-quality end-use load profiles (EULPs) provide this information and can help cities, states, and utilities understand the time-sensitive value of energy efficiency, demand response, and distributed energy resources. Publicly available EULPs have traditionally had limited application because of age and incomplete geographic representation. To help fill this gap, the U.S. Department of Energy funded a 3-year project, End-Use Load Profiles for the U.S. Building Stock, that culminated in this publicly available dataset of calibrated and validated 15-minute-resolution load profiles for all major residential and commercial building types and end uses across all climate regions in the United States. These EULPs were created by calibrating the ResStock and ComStock physics-based building stock models using many different measured datasets, as described in the "Technical Report Documenting Methodology" linked in the submission.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sampling-Based Motion Planning Algorithms for Replanning and Spatial Load Balancing

The common theme of this dissertation is sampling-based motion planning with the two key contributions being in the area of replanning and spatial load balancing for robotic systems. Here, we begin by recalling two sampling-based motion planners: the asymptotically optimal rapidly-exploring random tree (RRT*), and the asymptotically optimal probabilistic roadmap (PRM*). We also provide a brief background on collision cones and the Distributed Reactive Collision Avoidance (DRCA) algorithm. The next four chapters detail novel contributions for motion replanning in environments with unexpected static obstacles, for multi-agent collision avoidance, and spatial load balancing. First, we show improved performance of the RRT* when using the proposed Grandparent-Connection (GP) or Focused-Refinement (FR) algorithms. Next, the Goal Tree algorithm for replanning with unexpected static obstacles is detailed and proven to be asymptotically optimal. A multi-agent collision avoidance problem in obstacle environments is approached via the RRT*, leading to the novel Sampling-Based Collision Avoidance (SBCA) algorithm. The SBCA algorithm is proven to guarantee collision free trajectories for all of the agents, even when subject to uncertainties in the knowledge of the other agents’ positions and velocities. Given that a solution exists, we prove that livelocks and deadlock will lead to the cost to the goal being decreased. We introduce a new deconfliction maneuver that decreases the cost-to-come at each step. This new maneuver removes the possibility of livelocks and allows a result to be formed that proves convergence to the goal configurations. Finally, we present a limited range Graph-based Spatial Load Balancing (GSLB) algorithm which fairly divides a non-convex space among multiple agents that are subject to differential constraints and have a limited travel distance. The GSLB is proven to converge to a solution when maximizing the area covered by the agents. The analysis for each of the above mentioned algorithms is confirmed in simulations.

97 MATHEMATICS AND COMPUTING↗

End-Use Load Profiles for the U.S. Building Stock: Methodology and Results of Model Calibration, Validation, and Uncertainty Quantification

The United States is embarking on an ambitious transition to a 100% clean energy economy by 2050, which will require improving the flexibility of electric grids. One way to achieve grid flexibility is to shed or shift demand to align with changing grid needs. To facilitate this, it is critical to understand how and when energy is used. High- quality end-use load profiles (EULPs) provide this information, and can help cities, states, and utilities understand the time-sensitive value of energy efficiency, demand response, and distributed energy resources. Publicly available EULPs have traditionally had limited application because of age and incomplete geographic representation (Frick, Eckman, and Goldman 2017; Frick 2019). To help fill this gap, the U.S. Department of Energy (DOE) funded a three-year project - End-Use Load Profiles for the U.S. Building Stock - that culminated in the release of a publicly available dataset1 of simulated EULPs representing residential and commercial buildings across the contiguous United States. The motivation for this work is further detailed in a November 2019 report: Market Needs, Use Cases, and Data Gaps (Mims Frick et al. 2019). This Methodology and Results report provides detailed descriptions of how the dataset was developed, intended for an audience of dataset and model users interested in the technical details. These details include descriptions of all of the model improvements made for calibration and the final comparisons to empirical data sources. A companion report, End-Use Load Profiles for the U.S. Building Stock: Applications and Opportunities, will be published subsequently and will describe example applications and considerations for using the dataset, intended for an audience of general dataset users.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

MFVI Energy Efficiency Audit Training Module 2.2: Plug Loads Analysis [Slides]

This guide is designed to help trained energy efficiency professionals conduct an energy efficiency audit for commercial and industrial buildings, particularly for micro-, small-, and medium-sized businesses in Mexico. This guide is focused on auditing plug load systems. As such, it will assist its user in documenting the plug loads in the space and then identifying the most efficient means of delivering those plug loads.

21CPP↗

MFVI Energy Efficiency Audit Training Module 2.1: Plug Loads [Slides]

This guide is designed to help trained energy efficiency professionals conduct an energy efficiency audit for commercial and industrial buildings, particularly for micro-, small-, and medium-sized businesses in Mexico. This guide is focused on auditing plug load systems. As such, it will assist its user in documenting the plug loads in the space and then identifying the most efficient means of delivering those plug loads.

21CPP↗

Evaluation Of Glass Density to Support the Estimation of Fissile Mass Loadings in Sludge Batch 10 Glasses

Per a directive from the Department of Energy Savannah River Operations Office (DOE-SR) in 2008, the fissile mass loading concentration must remain below 897 g/m 3 in each high-level waste (HLW) glass canister produced by the Defense Waste Processing Facility (DWPF). To support Sludge Batch 5 (SB5) processing, the Savannah River National Laboratory (SRNL) developed a technical basis that facilitates the evaluation of fissile mass loading of the glass product. The calculation is based on the iron (Fe) concentration in the glass as determined by measurements from the Slurry Mix Evaporator acceptability analysis as well as the glass density. In April 2022, a subsequent DOE-SR directive increased the fissile mass loading limit to 2500 g/m 3 beginning with Sludge Batch 11. Thus, the 897 g/m 3 limit still applies to Sludge Batch 10 (SB10) processing. For SB5 through initial Sludge Batch 9 (SB9) processing prior to coupled operation with the Salt Waste Processing Facility (SWPF), SRNL provided DWPF a bounding glass density value that was based on a statistical evaluation of density measurements. To eliminate the need for experimental work, a composition-based density model for HLW glasses was developed at SRNL in 2019. The objective of this report is to present the bounding glass density determined with the composition-based density model for SB10 sludge-only (SO) and coupled processing.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaluation of Glass Density to Support the Estimation of Fissile Mass Loadings in Sludge Batch 10 Glasses

Per a directive from the Department of Energy Savannah River Operations Office (DOE-SR) in 2008, the fissile mass loading concentration must remain below 897 g/m 3 in each high-level waste (HLW) glass canister produced by the Defense Waste Processing Facility (DWPF). To support Sludge Batch 5 (SB5) processing, the Savannah River National Laboratory (SRNL) developed a technical basis that facilitates the evaluation of fissile mass loading of the glass product. The calculation is based on the iron (Fe) concentration in the glass as determined by measurements from the Slurry Mix Evaporator acceptability analysis as well as the glass density. In April 2022, a subsequent DOE-SR directive increased the fissile mass loading limit to 2500 g/m 3 beginning with Sludge Batch 11. Thus, the 897 g/m 3 limit still applies to Sludge Batch 10 (SB10) processing.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Study Highlights: Characterizing Plug Load Energy Use and Savings Potential in Army Buildings

A recent study of plug load devices in Army buildings has identified opportunities to save over 83 million kWh of electricity valued at over $5 million per year. These savings may be conservative and were identified by inventorying and monitoring plug load and miscellaneous electric load (MEL) equipment within representative Army buildings. The objective was to better understand the energy consumed by these devices and identify approaches for reducing it while enhancing resilience. This summary highlights the findings, lessons learned, and recommendations identified by the study.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Beneficial Integration of Energy Storage and Load Management with Photovoltaic (PV)

In recent years, a number of industry activities have aimed at addressing the integration challenges posed by the variability and uncertainty of higher penetration of renewable generation sources, like solar photovoltaic (PV) – one of the key objectives of the Sustainable and Holistic Integration of Energy Storage and Solar PV (SHINES) program launched by the U.S. Department of Energy's Office of Energy Efficiency and Renewable Energy (EERE). This EPRI led Beneficial Integration of Energy Storge, and Load Management with PV project aimed to design, develop, and demonstrate end-to-end distributed energy resource (DER) integration solution to build on these activities. EPRI led project team designed and implemented a local controller that uses model predictive control (MPC) algorithm to optimally manage DERs on site by planning for a receding horizon while executing the control settings for the first step of its plan. The team has also developed a system controller to interface with the local controller to demonstrate the hierarchical control and how it can leverage DER capabilities to address challenges like over voltage and thermal limit violations which typically limits the DER hosting capacity of distribution feeders. Team has demonstrated how the local controller with optimization algorithm can effectively manage controllable loads like HVAC, water heater, and pool pumps to allow for greater integration of PV with relatively smaller energy storage system requirements. Optimal utilization of the load control can also reduce the depth of discharge of batteries to meet grid export/import limit from behind-the-meter (BTM) DERs. Proper utilization of DER capabilities via local control intelligence, like the one developed and demonstrated in this project can help the industry to address integration challenges of higher penetration of solar PV in economically efficient manner. This can help to accelerate deployment of clean renewable energy systems at lower societal cost.

14 SOLAR ENERGY↗

Proactive Regulatory Approaches to Electrification and Load Growth: Workshop Report

On July 10 and 11, 2024, Pacific Northwest National Laboratory and RMI led a workshop in Aurora, Colorado, to explore novel and proactive approaches to electrification and load growth while minimizing risks and costs to customers. Over the next decade, a unique opportunity exists to invest strategically in the electricity system to enable electrification across the transportation, industrial, and building sectors and respond to data and technology-based load growth. However, current utility and regulatory planning practices are insufficient to identify and enable the right investments, and work must be done to reduce the risk and decisional uncertainty faced by utility regulatory commissions and utilities. Ensuring timely electrification investments may require new approaches to address risk, uncertainty, prudence, and cost recovery. Understanding the decision-making process and information needs of utilities and regulators is critical. New policies (or application of policies), financial tools, systems analysis, regulatory mechanisms, and enhanced process transparency may be required. The workshop's goal was to identify proactive regulatory approaches for electrification and load growth that minimize costs and risks to customers. Our intention was that the conversations and the resulting solutions and takeaways would be specific and tactical rather than general and theoretical and that together we would create actionable next steps for key actors in the system, including utilities, regulators, thought leaders, researchers, and the U.S. Department of Energy (DOE). This report is intended to provide workshop attendees with a record and summary of the discussion and proposals raised at the workshop and to provide interested entities who did not attend, such as other regulators, policymakers, utilities, and U.S. DOE offices, with an understanding of what was discussed and with ideas to explore in their organizations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Day-Ahead Probabilistic Forecasting of Net-Load and Demand Response Potentials with High Penetration of Behind-the-Meter Solar-plus-Storage

The goal of this project is to develop advanced methods for day-ahead net-load forecasting, by leveraging the state-of-the-art machine learning techniques. The developed models produce both point and probabilistic forecasts for a variety of use cases, and are versatile to work with different types of data sets. The innovation lies in the novel design of the architectures, leveraging the most recent advances in machine learning that have not been explored in power systems, accompanied by techniques in the broader artificial intelligence fields such as fuzzy systems. This project has achieved the following accomplishments: (1) preprocessing of over 10 data sets covering varying geographical regions, time horizons, and system levels, which form a robust foundation for training and evaluating forecasting models across a wide range of realistic grid scenarios; (2) development of an interactive web app that enables exploratory analysis of load and generation data, and supports better understanding of data trends, anomalies, and correlations, facilitating model development and stakeholder engagement; (3) implementation of over 10 benchmark models for point and probabilistic forecasting, which include a mix of conventional machine learning methods and state-of-the-art deep learning approaches, providing a comprehensive baseline for performance comparison and validation of the proposed models; (4) development of a fuzzy system based gradient boosting model, tailored for small (less than 3 years) data sets, which achieves a mean absolute percentage error (MAPE) of 4% for point forecasting and a 20% improvement in average pinball loss for probabilistic forecasting; (5) development of a Transformer (a state-of-the-art deep learning architecture) based neural network model, tailored for large (3 years or more) data sets, which achieves a MAPE of 2% for point forecasting and a 20% improvement in average pinball loss for probabilistic forecasting; (6) development of a methodology for quantifying DR potential, and extensions of the previous models for multi-target forecasting of net load and DR potential, which achieve a MAPE of 10% for DR potential.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Power Management Solution for Growing Loads at Airport Rental Facilities

Growing electrical loads across airport facilities could expand beyond local grid capacities. Coordinating flexible loads with generation and storage assets can reduce coincident peaks, mitigate costly upgrades, and reduce electricity costs. This report outlines how The Athena Team has developed a suite of tools, resources, and solutions to leverage load flexibility with energy assets to harness this value potential.

24 POWER TRANSMISSION AND DISTRIBUTION↗