Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “leak”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Heat/pressure seal for moving parts

Prototype seal keeps hot gases from leaking between large, adjacent parts in relative motion. Seal withstands temperatures greater than 1,000 degrees C (1800 degrees F) and accomodates heat and pressure caused distortion of parts. It is nonabrasive, creates little resistance to movement of parts, and causes minimal wear and damage to surface coatings.

Stevens, M. L.↗

Performance sensitivity analysis of Department of Energy-Chrysler upgraded automotive gas turbine engine, S/N 5-4

The performance sensitivity of a two-shaft automotive gas turbine engine to changes in component performance and cycle operating parameters was examined. Sensitivities were determined for changes in turbomachinery efficiency, compressor inlet temperature, power turbine discharge temperature, regenerator effectiveness, regenerator pressure drop, and several gas flow and heat leaks. Compressor efficiency was found to have the greatest effect on system performance.

Johnsen, R. L.↗

Cryogenic container compound suspension strap

A support strap for use in a cryogenic storage vessel for supporting the inner shell from the outer shell with a minimum heat leak is presented. The compound suspension strap is made from a unidirectional fiberglass epoxy composite material with an ultimate tensile strength and fatigue strength which are approximately doubled when the material is cooled to a cryogenic temperature.

Vorreiter, J. W.↗

Intra-ocular pressure normalization technique and equipment

A method and apparatus for safely reducing abnormally high intraocular pressure in an eye during a predetermined time interval is presented. This allows maintenance of normal intraocular pressure during glaucoma surgery. According to the invention, a pressure regulator of the spring biased diaphragm type is provided with additional bias by a column of liquid. The height of the column of liquid is selected such that the pressure at a hypodermic needle connected to the output of the pressure regulator is equal to the measured pressure of the eye. The hypodermic needle can then be safely inserted into the anterior chamber of the eye. Liquid is then bled out of the column to reduce the bias on the diaphragm of the pressure regulator and, consequently, the output pressure of the regulator. This lowering pressure of the regulator also occurs in the eye by means of a small second bleed path provided between the pressure regulator and the hypodermic needle. Alternately, a second hypodermic needle may be inserted into the eye to provide a controlled leak off path for excessive pressure and clouded fluid from the anterior chamber.

Mcgannon, W. J.↗

Cooling of High Pressure Rocket Thrust Chambers with Liquid Oxygen

An experimental program using hydrogen and oxygen as the propellants and supercritical liquid oxygen (LOX) as the coolant was conducted at 4.14 and 8.274 MN/square meters (600 and 1200 psia) chamber pressure. Data on the following are presented: the effect of LOX leaking into the combustion region through small cracks in the chamber wall; and verification of the supercritical oxygen heat transfer correlation developed from heated tube experiments; A total of four thrust chambers with throat diameters of 0.066 m were tested. Of these, three were cyclically tested to 4.14 MN/square meters (600 psia) chamber pressure until a crack developed. One had 23 additional hot cycles accumulated with no apparent metal burning or distress. The fourth chamber was operated at 8.274 MN/square meters (1200 psia) pressure to obtain steady state heat transfer data. Wall temperature measurements confirmed the heat transfer correlation.

Price, H. G.↗

Measurement of Aircraft Speed and Altitude

Problems involved in measuring speed and altitude with pressure-actuated instruments (altimeter, airspeed indicator, true-airspeed indicator, Machmeter, and vertical-speed indicator) are examined. Equations relating total pressure and static pressure to the five flight quantities are presented, and criteria for the design of total and static pressure tubes are given. Calibrations of typical static pressure installations (fuselage nose, wing tip, vertical fin, and fuselage vent) are presented, various methods for flight calibration of these installations are described, and the calibration of a particular installation by two of the methods is described in detail. Equations are given for estimating the effects of pressure lag and leaks. Test procedures for the laboratory calibration of the five instruments are described, and accuracies of mechanical and electrical instruments are presented. Operational use of the altimeter for terrain clearance and vertical separation of aircraft is discussed, along with flight technical errors and overall altitude errors of aircraft in cruise operations. Altitude-measuring techniques based on a variety of properties of the Earth and the atmosphere are included. Two appendixes present airspeed and altitude tables and sample calculations for determining the various flight parameters from measured total and static pressures.

Gracey, W.↗

Solar energy system performance evaluation: Seasonal report for Contemporary Newman, Newman, Georgia

A hot solar heating and hot water system's operational performance from June 1979 through April 1980 is evaluated. Solar energy satisfied 42 percent of the total measure load (hot water plus space heating), which was somewhat higher than the solar fraction of 32 percent. When system losses into the heating space from duct leaks and storage are included, the heating solar fraction increases from 42 to 64 percent. Net electrical energy savings were 5.47 million BTUs.

Source record↗

Aerothermal analysis of a wing-elevon cove with variable leakage

A mathematical model of the heating associated with leakage within the space shuttle orbiter wing elevon cove was used to analyze the aerothermal response of the structure. The analysis was applied to wind tunnel results and to shuttle entry conditions. A parametric study described the mechanism by which the energy of the ingested mass is distributed as a function of the Reynolds number, wall conductivity, surface emissivity, and cove height and length. The rate at which energy was transferred into the cove interior was primarily determined by the combined effects of the convection, wall capacitance, and internal radiation terms. Correlation with wind tunnel results indicated that the cold wall convective heating rates, wall temperature, and gas temperature of the cove were predicted by the analytical model for short exposure times. Predicted transient thermal response of the elevon cove subjected to shuttle entry conditions indicated that the allowable leak area at the cove seal was 20 percent less than that previously indicated by experiment.

Hunt, R. L.↗

A liquid hydrogen experiment as a Shuttle payload

The paper describes the cryogenic fluid management experiment (CFME) as a Shuttle payload. The experiment includes a liquid hydrogen tank containing a fine-mesh screen acquisition device, and a thermal control system consisting of a thermodynamic vent system to intercept heat leak to the hydrogen tank and control tank pressure. Engineering data obtained will be used to establish design criteria for subcritical cryogenic storage and supply tankage.

Eberhardt, R. N.↗

Cooling of high pressure rocket thrust chambers with liquid oxygen

An experimental program using hydrogen and oxygen as the propellants and supercritical liquid oxygen (LOX) as the coolant was conducted at 4.14 and 8.274 MN/sq m chamber pressure. It was aimed to demonstrate the effect of LOX leaking into the combustion region through small cracks in the chamber wall, and to verify the supercritical oxygen heat transfer correlation developed from heated tube experiments. Four thrust chambers with throat diameters of 0.066 m were tested; three of these were cyclically tested to 4.14 MM/sq m chamber pressure until a crack developed; the fourth chamber was operated at 8.274 MM/sq m pressure to obtain steady state heat transfer data. Wall temperature measurements confirmed the heat transfer correlation.

Price, H. G.↗

Gas distribution equipment in hydrogen service - Phase II

The hydrogen permeability of three different types of commercially available natural gas polyethylene pipes was determined. Ring tensile tests were conducted on permeability-exposed and as-received samples. Hydrogen-methane leakage experiments were also performed. The results show no selective leakage of hydrogen via Poiseuille, turbulent, or orifice flow (through leaks) on the distribution of blends of hydrogen and methane. The data collected show that the polyethylene pipe is 4 to 6 times more permeable to hydrogen than to methane.

Jasionowski, W. J.↗

Measuring Cyclic-Stress Properties of Pressure Vessels

Simulated-service cycle differs from conventional proof-test cycle in that specimen is subjected to sine-wave variation of stress instead of prolonged steady stress. Simulated-service testing is performed at low and high temperatures as well as at room temperatures. (Flaws initiated by severe stresses of proof testing can later develop into leaks during service, thus effectively reducing useful service life.) Method may be useful for commercial thin-wall vessels.

Fiftal, C. F.↗

Faster Test for Cable Seals

Vacuum-assisted immersion test is much faster than conventional atmospheric immersion tests of cable seals. Vacuum speeds removal of air, allowing its replacement by conductive salt solution in leaking specimens. Previously, 24-hour immersion was necessary to assure displacement of trapped air. Improved method takes only 10 minutes.

Shephard, A. T.↗

Improved High-Temperature Seal

High-temperature seals on Space Shuttle Orbiter elevons will be improved by a new flexible seal design that increases the number of leak barriers, allows for thermal expansion and cuts weight by more than two-thirds. Improved seal may be useful in applications where it is necessary to seal gaps between moving surfaces.

Wood, K. E.↗

Preliminary Arc-Jet tests of ablator/RSI joints in simulated space shuttle ascent and entry heating

Five ablator/RSI panels were tested in simulated Shuttle heating conditions to determine heat pulse effects on the ablator and the ablator/RSI joints. Two of the panels were subjected to both ascent and entry heating. The other three panels were subjected to entry heating only. The double-pulse heating (ascent plus entry) had no significant effect on char-layer integrity. Evaluation of the effects of entry heating on the ablator/RSI joints was difficult because, with the panel configuration used, severe pressure gradients developed within some of the joints during testing causing hot-gas flow through the joints. In joints where pressure leaks apparently did not develop, temperatures within the joints were reasonable compared to ablator and RSI back surface temperatures.

Brewer, W. D.↗

Initial evaluation tests of General Electric Company 12.0 ampere hour nickel cadmium spacecraft cells with design variables

All evaluation tests were performed at room ambient pressure and temperature, with discharges at a 2 hour rate. Tests consisted of phenolphthalein leak tests, three capacity tests, an auxiliary electrode test, a charge retention test, an internal short test, a charge efficiency test, overcharge tests, and a pressure versus capacity test. Results of the tests and recommendations for improvements in manufacturing are presented.

Harkness, J. D.↗

Jet-diffuser Ejector - Attached Nozzle Design

Attached primary nozzles were developed to replace the detached nozzles of jet-diffuser ejectors. Slotted primary nozzles located at the inlet lip and injecting fluid normal to the thrust axis, and rotating the fluid into the thrust direction using the Coanda Effect were investigated. Experiments indicated excessive skin friction or momentum cancellation due to impingement of opposing jets resulted in performance degradation. This indicated a desirability for location and orientation of the injection point at positions removed from the immediate vicinity of the inlet surface, and at an acute angle with respect to the thrust axis. Various nozzle designs were tested over a range of positions and orientations. The problems of aircraft integration of the ejector, and internal and external nozzle losses were also considered and a geometry for the attached nozzles was selected. The effect of leaks, protrusions, and asymmetries in the ejector surfaces was examined. The results indicated a relative insensitivity to all surface irregularities, except for large protrusions at the throat of the ejector.

Alperin, M.↗

Design and fabrication of a stringer stiffened discrete-tube actively cooled panel for a hypersonic aircraft

A 0.61 x 1.22 m (2 x 4 ft) test panel was fabricated and delivered to the Langley Research Center for assessment of the thermal and structural features of the optimized panel design. The panel concept incorporated an aluminum alloy surface panel actively cooled by a network of discrete, parallel, redundant, counterflow passage interconnected with appropriate manifolding, and assembled by adhesive bonding. The cooled skin was stiffened with a mechanically fastened conventional substructure of stringers and frames. A 40 water/60 glycol solution was the coolant. Low pressure leak testing, radiography, holography and infrared scanning were applied at various stages of fabrication to assess integrity and uniformity. By nondestructively inspecting selected specimens which were subsequently tested to destruction, it was possible to refine inspection standards as applied to this cooled panel design.

Anthony, F. M.↗