Visoelastic damping in free vibrations of laminates
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
For abstract, see N78-24577.
Article discusses procedure where hydrazine is used to extract graphite fibers from cured polyimide resin. Method does not attack graphite fibers and is faster than hot-concentrated-acid digestion process.
An approximate solution is developed for the determination of the interlaminar normal and shear stresses in the vicinity of a crack in a three dimensional composite containing unidirectional linearly elastic fibers in an infinite linearly elastic matrix. In order to reduce the complexity of the formulation, certain assumptions are made as to the physically significant stresses to be retained. These simplifications reduce the partial differential equations of elasticity to differential-difference equations which are tractable using Fourier transform techniques. The potential for damaged or debonded zones to be generated by an embedded crack is discussed, and stress concentration factors for fibers near the crack are given. Detailed comparisons are made between the present solution, the analogous two dimensional problem, and corresponding shear-lag models.
Cross-layered woven or unwoven yarns are used to provide an active thermal control mechanism for spacecraft use. One set of yarns is composed of flexible electrically conductive metal fibers which are capable of being resistance heated by the application of voltage. Another set of yarns, nonconductive and flexible, provides mechanical strength and precludes the passage of electrical current between the metal yarns by virtue of the spacing between them. A lightweight, electrically nonconductive film is bonded to the cross-layered yarns to protect the metal yarns from the elements (minimize electrical shorts from moisture such as rain), to provide additional strength to the fabric, and to prevent conductive loss of heat in nonvacuum applications. The nonconductive film is metalized on its obverse side to provide a more uniform heat load distribution.
The form of the moisture distribution in the specimen (gradient and flat profile) was considered to establish the influence of accelerated moisture conditioning on fatigue behavior. For the gradient specimens having an average moisture content of 1.4 percent, fatigue life was reduced by a factor of 8 at all stress levels investigated. Corresponding reduction in fatigue life for the flat moisture profile specimens at the same average moisture content was comparatively smaller, being about a factor of 5 from the value in dry specimens. X-ray radiographic analysis of damage accumulation in compression-compression fatigue revealed interlaminar cracking to be the dominant mode of failure responsible for the observed enhanced cyclic degradation of moisture-conditioned specimens. This finding was corroborated by the observed systematic reduction in interlaminar shear strength as a function of moisture content, which, in turn, increased the propensity for delamination under cyclic compressive loads. Residual strength measurements on cycled specimens indicated significant strength reductions at long lives, particularly in moisture conditioned specimens.
Traction motor using two types of excitation: ripple free dc from a motor generator set for baseline data and chopped dc as supplied by a battery and chopper controller was tested. For the same average values of input voltage and current, the power output was independent of the type of excitation. At the same speeds, motor efficiency at low power output (corresponding to low duty cycle of the controller) was 5 to 10 percentage points less on chopped dc than on ripple-free dc. This illustrates that for chopped waveforms, it is incorrect to calculate input power as the product of average voltage and average current. Locked-rotor torque, no load losses, and magnetic saturation data were so determined.
Explore the source record for details and available documents.
The application of advanced composite materials in aerospace, ground transportation, and sporting industries are discussed. Failure theories for the design and mechanical behavior of composite materials are emphasized. Methods for detecting specific types of flaws are outlined. The effect of detected flaws on mechanical properties such as stiffness, strength, fatigue lifetime, or residual strength is described.
The paper studies the influence of hole quality on the structural behavior of composite materials. Static and fatigue pin bearing and compression test results are presented and discussed. These results show that a hole chipout defect reduces static and cyclic endurance characteristics.
Solutions are developed for the two dimensional region containing unidirectional fibers with initial damage in the form of a notch, a rectangular cut out, and a circular hole. An ultimate stress failure criterion is used for both the fibers and the matrix, simple tension for the fibers, and shear failure for the matrix. Models which account for longitudinal matrix yielding and splitting as well as transverse matrix yielding and fiber breakage as a function of initial damage, material properties, and applied stress are presented. For ductile matrix composites the results indicate that longitudinal matrix yielding and transverse notch extension are the most significant forms of damage. The extent of the stable transverse damage is shown to be approximately constant, independent of initial notch length. In the case of brittle matrix composites (graphite/epoxy) longitudinal splitting is shown to be the dominant form of damage.
Explore the source record for details and available documents.
(Previously announced in STAR as N82-23554)
The influence of a thermal spike on a moisture-saturated graphite/epoxy composite was studied in detail. A single thermal spike from 25 C to 132 C was found to produce damage as evidenced by a significant increase in the level of moisture saturation in the composite. Approximately half of this increase remained after a vacuum anneal at 150 C for 7 days, suggesting the presence of an irreversible damage component. Subsequent thermal spikes created less and less additional moisture absorption, with the cumulative effect being a maximum or limiting moisture capacity of the composite. These observations are explained in terms of a model previously developed to explain the reverse thermal effect of moisture absorption in epoxy and epoxy matrix composites. This model, based on the inverse temperature dependence of free volume, contributes an improved understanding of thermal-spike effects in graphite/epoxy composites.
The nonlinear vibration response of a double cantilevered beam subjected to pulse loading over a central sector is studied. The initial response is generated in detail to ascertain the energetics of the response. The total energy is used as a gauge of the stability and accuracy of the solution. It is shown that to obtain accurate and stable initial solutions an extremely high spatial and time resolution is required. This requirement was only evident through an examination of the energy of the system. It is proposed, therefore, to use the total energy of the system as a necessary stability and accuracy criterion for the nonlinear response of conservative systems. The results also demonstrate that even for moderate nonlinearities, the effects of membrane forces have a significant influence on the system.
This presentation attempts to characterize the compressive behavior of Hercules AS-1/3501-6 graphite-epoxy composite. The effect of varying specimen geometry on test results is examined. The transition region is determined between buckling and compressive failure. Failure modes are defined and analytical models to describe these modes are presented.
Clamped circular graphite/epoxy plates (25.4, 38.1, and 50.8 mm radii) with an 8-ply quasi-isotropic layup were analyzed for static-equivalent impact loads using the minimum-total-potential-energy method and the von Karman strain-displacement equations. A step-by-step incremental transverse displacement procedure was used to calculate plate load and ply stresses. The ply failure region was calculated using the Tsai-Wu criterion. The corresponding failure modes (splitting and fiber failure) were determined using the maximum stress criteria. The first-failure mode was splitting and initiated first in the bottom ply. The splitting-failure thresholds were relatively low and tended to be lower for larger plates than for small plates. The splitting-damage region in each ply was elongated in its fiber direction; the bottom ply had the largest damage region. The calculated damage region for the 25.4-mm-radius plate agreed with limited static test results from the literature.
Explore the source record for details and available documents.