Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “interpolated”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Local structure of reaction intermediates probed by time-resolved x-ray absorption near edge structure spectroscopy

A method for the analysis of time-resolved x-ray absorption near edge structure (XANES) spectra is proposed. It combines principal component analysis of the series of experimental spectra, multidimensional interpolation of theoretical XANES as a function of structural parameters, and ab initio XANES calculations. It allows to determine the values of structural parameters for intermediates of chemical reactions and the concentrations of different states as a function of time. This approach is tested using numerically generated data and its possibilities and limitations are discussed. The application of this method to a reaction with methylrhenium trioxide catalyst in solution, for which experimental data were measured using stopped-flow energy-dispersive x-ray absorption spectroscopy technique, is demonstrated. Possibilities and limitations of this experimental technique are also discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modeling Nuclear Pasta and the Transition to Uniform Nuclear Matter with the 3D-Skyrme-Hartree-Fock Method

The first results of a new three-dimensional, finite temperature Skyrme-Hartree-Fock+BCS study of the properties of inhomogeneous nuclear matter at densities and temperatures leading to the transition to uniform nuclear matter are presented. A constraint is placed on the two independent components of the quadrupole moment in order to self-consistently explore the shape phase space of nuclear configurations. The scheme employed naturally allows effects such as (i) neutron drip, which results in an external neutron gas, (ii) the variety of exotic nuclear shapes expected for extremely neutron heavy nuclei, and (iii) the subsequent dissolution of these nuclei into nuclear matter. In this way, the equation of state can be calculated across phase transitions from lower densities (where one dimensional Hartree-Fock suffices) through to uniform nuclear matter without recourse to interpolation techniques between density regimes described by different physical models.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Unified expression for the rate constant of the bridged electron transfer derived by renormalization

Electron transfer (ET) from a donor to an acceptor through an energetically close intermediary state on a midway molecule is a process found often in natural and artificial solar-energy capturing systems such as photosynthesis. This process has often been thought of in terms of opposing 'superexchange' and 'sequential or hopping' mechanisms, and the recent theory of Sumi and Kakitani (SK) [J. Phys. Chem. B 105, 9603 (2001)] has shown an interpolation between these mechanisms. In their theory, however, dynamics governing the most interesting intermediary region between them has artificially been introduced by phenomenologies. The dynamics is played by decoherence among electronic states, their decay, and thermalization of phonons in the medium. The present work clarifies the dynamics on a microscopic basis by means of renormalization in electronic coupling among the states, and gives a complete unified expression of the rate constant of the ET. It merges to that given by the SK theory in the semiclassical approximation for phonons interacting with an electron transferred.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Adiabatic approximation with exponential accuracy for many-body systems and quantum computation

We derive a version of the adiabatic theorem that is especially suited for applications in adiabatic quantum computation, where it is reasonable to assume that the adiabatic interpolation between the initial and final Hamiltonians is controllable. Assuming that the Hamiltonian is analytic in a finite strip around the real-time axis, that some number of its time derivatives vanish at the initial and final times, and that the target adiabatic eigenstate is nondegenerate and separated by a gap from the rest of the spectrum, we show that one can obtain an error between the final adiabatic eigenstate and the actual time-evolved state which is exponentially small in the evolution time, where this time itself scales as the square of the norm of the time derivative of the Hamiltonian divided by the cube of the minimal gap.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Time-Depending Parametric Variational Approach for an Economic General Equilibrium Problem of Pure Exchange with Application

This paper considers a qualitative analysis of the solution of a pure exchange general economic equilibrium problem according to two independent parameters. Some recently results obtained by the author in the static and the dynamic case have been collected. Such results have been applied in a particular parametric case: it has been focused the attention on a numerical application for which the existence of the solution of time-depending parametric variational inequality that describes the equilibrium conditions has been proved by means of the direct method. By using MatLab computation after a linear interpolation, the curves of equilibrium have been visualized.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Heydemann Algorithm for Energy Scale Linearisation

Many monochromators rely on quadrature encoders for positioning optical elements like gratings or mirrors. In most cases the required accuracy is significantly higher than the pitch of the encoders and an interpolation scheme becomes necessary. The accuracy of this procedure can be significantly enhanced, if signal errors in the detection systems are compensated. We report on the implementation of this technique at the BESSY monochromators and the impact on spectroscopic data.

97 MATHEMATICS AND COMPUTING↗

Two color multichannel heterodyne interferometer set up for high spatial resolution electron density profile measurements in TJ-II

A high spatial resolution two color [CO{sub 2}, {lambda}=10.6 {mu}m/Nd:YAG (Nd:YAG denotes neodymium-doped yttrium aluminum garnet), and {lambda}=1.064 {mu}m] expanded-beam multichannel heterodyne interferometer has been installed on the TJ-II stellarator. Careful design of the optical system has allowed complete control on the evolution of both Gaussian beams along the interferometer, as well as the evaluation and optimization of the spatial resolution to be expected in the measurements. Five CO{sub 2} (measurement) channels and three Nd:YAG (vibration compensation) channels have been used to illuminate the plasma with a probe beam of 100 mm size. An optimum interpolation method has been applied to recover both interferometric phasefronts prior to mechanical vibration subtraction. The first results of the installed diagnostic are presented in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pion Form Factor in Improved Holographic QCD Backgrounds

We extend our recent numerical calculation of the pion electromagnetic form factor F{sub {pi}}(Q{sup 2}) in holographic QCD with a background field that interpolates between 'hard-wall' and 'soft-wall' models to obtain an improved model that reproduces the desirable phenomenological features of both. In all cases, F{sub {pi}}for large Q{sup 2} is shallower than data, an effect that can be cured by relaxing the fit to one of the static observables, particularly the decay constant f{sub {pi}}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The {sup 12}C({sup 3}He,p{gamma}){sup 14}N reaction cross section for {gamma}-ray spectroscopy simulation of fusion plasmas

High resolution {gamma}-ray spectroscopy measurements were performed in JET ({sup 3}He)D plasmas with high energy ion populations driven by radio-frequency (RF) heating. One of the first reactions investigated was {sup 12}C({sup 3}He,p{gamma}){sup 14}N, which was observed at low {sup 3}He concentrations. In order to interpret the measurements in this work, cross section data for the {sup 12}C({sup 3}He,p{gamma}){sup 14}N reaction are evaluated. Available data for the population of excited states in {sup 14}N up to the eighth level are assessed in the range E{sub 3He}=0-5 MeV. Discrepancies and gaps in the database have been solved by means of interpolations and consistency analysis. The evaluated cross section data are used to predict the intensity ratio of characteristic 2.31 and 1.63 MeV {gamma}-rays.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a Beam Hardening Correction Method for a microCT Scanner Prototype

The radiographic projections acquired with a microCT were simulated and then corrected for beam hardening effects using the linearized signal to equivalent thickness (LSET) method. This procedure requires a calibration signal for each pixel obtained from a set of images with filters of increasing thickness. The projections are corrected by converting the signal to an equivalent thickness using interpolation over the calibration images. The method was validated using simulated projections of different phantoms. Two calibration sets were simulated using aluminum and water filters of thicknesses ranging from 0 to 5 mm and from 0 to 50 mm, respectively. A simulation of the phantoms' projections using a monoenergetic beam was also obtained to establish the relative intensity on the tomographic images when no cupping artifacts are present. Comparison between corrected and uncorrected tomographic images shows that the LSET method effectively corrects the cupping artifact. Streaking artifacts correction with the LSET method shows better results than with the traditional water correction method. Results are independent of the two calibration materials used.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Roper Resonance in 2+1 Flavor QCD

The low-lying even-parity states of the nucleon are explored in lattice QCD using the PACS-CS collaboration 2+1-flavor dynamical-QCD gauge-field configurations. The established correlation-matrix approach is used, in which various fermion source and sink smearings are utilized to provide an effective basis of interpolating fields to span the space of low-lying energy eigenstates. Of particular interest is the nature of the first excited state of the nucleon, the N(1/2){sup +} Roper resonance of P{sub 11} pion-nucleon scattering. The Roper state of the present analysis approaches the physical mass, displaying significant chiral curvature at the lightest quark mass. These full QCD results, providing the world's first insight into the nucleon mass spectrum in the light-quark regime, are significantly different from those of quenched QCD and provide interesting insights into the dynamics of QCD.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Modelling Viscoelastic Behaviour of Polymer by A Mixed Velocity, Displacement Formulation - Numerical and Experimental Results

The objective of this work is to model the viscoelastic behaviour of polymer from the solid state to the liquid state. With this objective, we perform experimental tensile tests and compare with simulation results. The chosen polymer is a PMMA whose behaviour depends on its temperature. The computation simulation is based on Navier-Stokes equations where we propose a mixed finite element method with an interpolation P1+/P1 using displacement (or velocity) and pressure as principal variables. The implemented technique uses a mesh composed of triangles (2D) or tetrahedra (3D). The goal of this approach is to model the viscoelastic behaviour of polymers through a fluid-structure coupling technique with a multiphase approach.

36 MATERIALS SCIENCE↗

Calculations of the thermal conductivity of National Ignition Facility target materials at temperatures near 10 eV and densities near 10 g/cc using finite-temperature quantum molecular dynamics

Using quantum finite-temperature density functional theory molecular dynamics (QMD), we performed simulations of several important materials in the Inertial Confinement Fusion-National Ignition Facility nominal target designs, comprising various mixtures of proposed ablator materials (Be or CH) with the DT fuel. Simulations were done over a range of temperatures between 5 eV and 20 eV, at densities between 7.5 and {approx}12.5 g/cc. From the QMD trajectories, we calculated the electrical and thermal conductivity. We estimated the number of free electrons per atom by fitting the frequency-dependent electrical conductivity to the Drude formula. The thermal conductivity of the fuel increases with density but that of the ablator material is insensitive to modest density variations. We find that the thermal conductivity depends strongly on the ablator/fuel mix fraction but a Faber-Ziman interpolation scheme provides a reasonable approximation. We also compare our QMD results to the Hubbard and Lee-More models.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Geometric integration of the Vlasov-Maxwell system with a variational particle-in-cell scheme

A fully variational, unstructured, electromagnetic particle-in-cell integrator is developed for integration of the Vlasov-Maxwell equations. Using the formalism of discrete exterior calculus [Desbrun et al., e-print arXiv:math/0508341 (2005)], the field solver, interpolation scheme, and particle advance algorithm are derived through minimization of a single discrete field theory action. As a consequence of ensuring that the action is invariant under discrete electromagnetic gauge transformations, the integrator exactly conserves Gauss's law.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Absolute calibration method for nanosecond-resolved, time-streaked, fiber optic light collection, spectroscopy systems

This paper describes a convenient and accurate method to calibrate fast (<1 ns resolution) streaked, fiber optic light collection, spectroscopy systems. Such systems are inherently difficult to calibrate due to the lack of sufficiently intense, calibrated light sources. Such a system is used to collect spectral data on plasmas generated in electron beam diodes fielded on the RITS-6 accelerator (8-12MV, 140-200kA) at Sandia National Laboratories. On RITS, plasma light is collected through a small diameter (200 {mu}m) optical fiber and recorded on a fast streak camera at the output of a 1 meter Czerny-Turner monochromator. For this paper, a 300 W xenon short arc lamp (Oriel Model 6258) was used as the calibration source. Since the radiance of the xenon arc varies from cathode to anode, just the area around the tip of the cathode ('hotspot') was imaged onto the fiber, to produce the highest intensity output. To compensate for chromatic aberrations, the signal was optimized at each wavelength measured. Output power was measured using 10 nm bandpass interference filters and a calibrated photodetector. These measurements give power at discrete wavelengths across the spectrum, and when linearly interpolated, provide a calibration curve for the lamp. The shape of the spectrum is determined by the collective response of the optics, monochromator, and streak tube across the spectral region of interest. The ratio of the spectral curve to the measured bandpass filter curve at each wavelength produces a correction factor (Q) curve. This curve is then applied to the experimental data and the resultant spectra are given in absolute intensity units (photons/sec/cm{sup 2}/steradian/nm). Error analysis shows this method to be accurate to within +/- 20%, which represents a high level of accuracy for this type of measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Precise calibration of Mg concentration in Mg{sub x}Zn{sub 1-x}O thin films grown on ZnO substrates

The growth techniques for Mg{sub x}Zn{sub 1-x}O thin films have advanced at a rapid pace in recent years, enabling the application of this material to a wide range of optical and electrical applications. In designing structures and optimizing device performances, it is crucial that the Mg content of the alloy be controllable and precisely determined. In this study, we have established laboratory-based methods to determine the Mg content of Mg{sub x}Zn{sub 1-x}O thin films grown on ZnO substrates, ranging from the solubility limit of x {approx} 0.4 to the dilute limit of x < 0.01. For the absolute determination of Mg content, Rutherford backscattering spectroscopy is used for the high Mg region above x = 0.14, while secondary ion mass spectroscopy is employed to quantify low Mg content. As a lab-based method to determine the Mg content, c-axis length is measured by x-ray diffraction and is well associated with Mg content. The interpolation enables the determination of Mg content to x = 0.023, where the peak from the ZnO substrate overlaps the Mg{sub x}Zn{sub 1-x}O peak in standard laboratory equipment, and thus limits quantitative determination. At dilute Mg contents below x = 0.023, the localized exciton peak energy of the Mg{sub x}Zn{sub 1-x}O films as measured by photoluminescence is found to show a linear Mg content dependence, which is well resolved from the free exciton peak of ZnO substrate down to x = 0.0043. Our results demonstrate that x-ray diffraction and photoluminescence in combination are appropriate methods to determine Mg content in a wide Mg range from x = 0.004 to 0.40 in a laboratory environment.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Adjustments to the ICVGT scale of INRIM

At the 8{sup th} Temperature Symposium the results have been presented for the Interpolating Constant Volume Gas thermometer at INRIM (then IMGC), featuring a cryogenic pressure transducer, with an expanded uncertainty of less then 1.5 mK. However, for its fixed points this scale still relied on a NPL calibration as carried by rhodium-iron thermometer 232324. After the clarification, in 2005, by the Consultative Committee on Thermometry (CCT) of the definition of the equilibrium hydrogen (e-H2) triple point this scale was due to be adjusted for the isotopic content in the e-H2 fixed point cell. Only when this thermometer was re-calibrated in 2010 at INRIM at the three fixed points of the ICVGT was this adjustment performed, being the isotopic composition of the hydrogen cell known. With the start of the Neon Project in 2005, it became clear that a second adjustment would soon be needed, once the CCT will have decided on the way to deal with the isotopic composition of neon. The paper presents the experimental data of 2010, discusses the stability of the thermometer, and the size of the correction at the hydrogen point and of the likely correction (and its uncertainty) to be applied to the neon point, the isotopic composition of this cell being known as well.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multiscale multiphysics and multidomain models—Flexibility and rigidity

The emerging complexity of large macromolecules has led to challenges in their full scale theoretical description and computer simulation. Multiscale multiphysics and multidomain models have been introduced to reduce the number of degrees of freedom while maintaining modeling accuracy and achieving computational efficiency. A total energy functional is constructed to put energies for polar and nonpolar solvation, chemical potential, fluid flow, molecular mechanics, and elastic dynamics on an equal footing. The variational principle is utilized to derive coupled governing equations for the above mentioned multiphysical descriptions. Among these governing equations is the Poisson-Boltzmann equation which describes continuum electrostatics with atomic charges. The present work introduces the theory of continuum elasticity with atomic rigidity (CEWAR). The essence of CEWAR is to formulate the shear modulus as a continuous function of atomic rigidity. As a result, the dynamics complexity of a macromolecular system is separated from its static complexity so that the more time-consuming dynamics is handled with continuum elasticity theory, while the less time-consuming static analysis is pursued with atomic approaches. We propose a simple method, flexibility-rigidity index (FRI), to analyze macromolecular flexibility and rigidity in atomic detail. The construction of FRI relies on the fundamental assumption that protein functions, such as flexibility, rigidity, and energy, are entirely determined by the structure of the protein and its environment, although the structure is in turn determined by all the interactions. As such, the FRI measures the topological connectivity of protein atoms or residues and characterizes the geometric compactness of the protein structure. As a consequence, the FRI does not resort to the interaction Hamiltonian and bypasses matrix diagonalization, which underpins most other flexibility analysis methods. FRI's computational complexity is of O(N{sup 2}) at most, where N is the number of atoms or residues, in contrast to O(N{sup 3}) for Hamiltonian based methods. We demonstrate that the proposed FRI gives rise to accurate prediction of protein B-Factor for a set of 263 proteins. We show that a parameter free FRI is able to achieve about 95% accuracy of the parameter optimized FRI. An interpolation algorithm is developed to construct continuous atomic flexibility functions for visualization and use with CEWAR.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗