Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “imaging and visualization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Developing Extended Reality Projects in Support of Design, Fabrication and Procedure

The goal of this internship was to improve and create virtual reality simulations and visualizations for use in parallel with the design, fabrication, and analysis of flight ready hardware for areas like the Environmental Control and Life Support Systems (ECLSS) and also Space Systems. Specifically, my work was done in the XRSpace lab at Marshall Space Flight Center (MSFC) with assistance directly and indirectly from workers at KSC, JSC and LaRC. Led by David Reynolds, the XRSpace lab develops products for various entities at NASA. The work done in the XRSpace lab focuses on Extended Reality (XR) solutions for both simulations and visualization capabilities. The goal of the lab is to support the larger systems of NASA and to help find ways that XR technologies can streamline and optimize the design process. Extended Reality is an umbrella term that encompasses Mixed Reality, Augmented Reality, and Virtual Reality. In this capacity, I was able to complete several elements in the design, building, testing, and deployment for a variety of immersive experiences, including a VR procedure simulation, visualization aids, and a 360-image capture tool.

Joseph Chambers↗

On the Nature of AGN and Star Formation Enhancement in thez=3.1 SSA22Protocluster: The HST WFC3 IR View

We examine possible environmental sources of the enhanced star formation and active galactic nucleus (AGN) activity in the z=3.09 SSA22 protocluster using Hubble WFC3 F160W (∼1.6μm) observations of the SSA22 field, including new observations centered on eight X-ray selected protocluster AGN. To investigate the role of mergers in the observed AGN and star formation enhancement, we apply both quantitative (Sérsic-fit and Gini–M20)and visual morphological classifications to F160W images of protocluster Lyman-break galaxies (LBGs) in the fields of the X-ray AGN and z∼3field LBGs in SSA22 and GOODS-N. We find no statistically significant differences between the morphologies and merger fractions of protocluster and field LBGs, though we are limited by small number statistics in the protocluster. We also fit the UV-to-near-IR spectral energy distributions of F160W-detected protocluster and field LBGs to characterize their stellar masses and star formation histories. We find that the mean protocluster LBG is a factor of∼2 times more massive and more attenuated than the mean z∼3field LBG. We take our results to suggest that ongoing mergers are not more common among protocluster LBGs than field LBGs, though protocluster LBGs appear to be more massive. We speculate that the larger mass of the protocluster LBGs contributes to the enhancement of SMBH mass and accretion rate in the protocluster, which in turn drives the observed protocluster AGN enhancement

Erik B. Monson↗

Asymmetric Flow State Switching in the Space Launch System Block 2 Liftoff Environment

An in-depth investigation was conducted at the NASA Langley Research Center 14- by 22-Foot Subsonic Tunnel to evaluate flow state switching in the liftoff flow environment of the Space Launch System Block 2 Crew launch vehicle using force measurements, two-component particle image velocimetry, and tuft flow visualization. Multimodal flow states were observed in the gap flow between the centerbody and solid rocket boosters at a range of incoming flow angles and were characterized for the relative strength of state switches. When flow switches occur, the flow is predominantly bimodal, but trimodal flow states are observed with the launch tower downstream of the vehicle. Tuft visualization indicates three-dimensionality during flow state switching, which initiates at one part of the gap and quickly transitions throughout the length of the booster. Due to the long time scales between switches, statistics such as frequency of flow state switches and converged state probabilities cannot be established without significantly increased acquisition times.

Lee J. Mears↗

Asymmetric Flow State Switching on the Space Launch System (SLS) Block 2 Crew Vehicle

An in-depth investigation was conducted at the NASA Langley Research Center 14- by 22-Foot Subsonic Tunnel to evaluate flow state switching in the liftoff flow environment of the Space Launch System Block 2 Crew launch vehicle using side force measurements, two-component particle image velocimetry, and tufts flow visualization. Multimodal flow states were observed in the gap flow between the centerbody and solid rocket boosters at a range of incoming flow angles and were characterized for the relative strength of state switches. When flow switches occur, the flow is predominantly bimodal, but trimodal flow states are observed with the launch tower downstream of the vehicle. Tufts visualization indicates three-dimensionality during flow state switching, which initiates at one part of the gap and quickly transitions throughout the length of the booster. Due to the long time scales between switches, statistics such as frequency of flow state switches and converged state probabilities cannot be established without significantly increased acquisition times.

Lee J. Mears↗

Validation Experiments for Turbulent Separation over an Axisymmetric Body of Revolution

Historically, the flow physics involved with most turbulent separated flows have presented fundamental challenges to validating numerical approaches. As recognized by the CFD Vision 2030 study commissioned by NASA, validation of Reynolds-averaged Navier-Stokes (RANS) models and other scale-resolving methods for turbulent separated flow requires data from advanced, high-fidelity experiments designed specifically for CFD implementation. In accordance with this effort, a new test platform, referred to as the NASA Axisymmetric Afterbody, was designed to obtain detailed measurements of the flow field undergoing a smooth, adverse pressure gradient induced separation for a fixed Reynolds number, Re = 180,000. The parametric body offers a range of flow states progressing from fully attached, to incipient separation, and finally to small-scale separated flow based on variable afterbody geometries. In an initial effort to evaluate RANS turbulence model capabilities, the present configurations of the axisymmetric model host a mild adverse pressure gradient over the contoured boattail section, inducing incipient turbulent separation, as well as a slightly larger adverse pressure gradient, inducing a small-scale region of turbulent separation. Experiments include steady pressure measurements and 2-D PIV to provide the preliminary dataset for simulation studies, which examine the effect of variable grid domains and RANS turbulence models. This is done in an effort to understand and evaluate the critical variability between solutions for the present model configurations. Results indicate potential discrepancies may be due to the effect of the square tunnel test section walls, relatively large blockage ratio, and slight variability in reference parameters. Ongoing work will focus on higher fidelity experimental campaigns to obtain surface flow visualizations and Stereo-Particle Image Velocimetry (SPIV) to deliver higher spatial resolution of the three-dimensional flow field to aid turbulence modelers.

Validation↗

Mixing-induced calcite precipitation and dissolution kinetics in micromodel experiments.

Dissolved CO2 from geological CO2 sequestration may react with dissolved minerals in fractured rocks or confined aquifers and cause mineral precipitation. The overall rate of reaction can be limited by diffusive or dispersive mixing, and mineral precipitation can block pores and further hinder these processes. Mixing-induced calcite precipitation experiments were performed by injecting solutions containing CaCl2 and Na2CO3 through two separate inlets of a micromodel (1-cm x 2-cm x 40-microns); transverse dispersion caused the two solutions to mix along the center of the micromodel, resulting in calcite precipitation. The amount of calcite precipitation initially increased to a maximum and then decreased to a steady state value. Fluorescent microscopy and imaging techniques were used to visualize calcite precipitation, and the corresponding effects on the flow field. Experimental micromodel results were evaluated with pore-scale simulations using a 2-D Lattice-Boltzmann code for water flow and a finite volume code for reactive transport. The reactive transport model included the impact of pH upon carbonate speciation and calcite dissolution. We found that proper estimation of the effective diffusion coefficient and the reaction surface area is necessary to adequately simulate precipitation and dissolution rates. The effective diffusion coefficient was decreased in grid cells where calcite precipitated, and keeping track of reactive surface over time played a significant role in predicting reaction patterns. Our results may improve understanding of the fundamental physicochemical processes during CO2 sequestration in geologic formations.

54 ENVIRONMENTAL SCIENCES↗

Nondestructive Evaluation of Thick Concrete Structures

Materials issues are a key concern for the existing nuclear reactor fleet in the United States as material degradation can lead to increased maintenance, increased downtime, and increased risk. Extending reactor life to 60 years and beyond will likely increase susceptibility and severity of both known and new forms of degradation. A multitude of concrete-based structures are typically part of a light water reactor plant to provide foundation, support, shielding, and containment functions. The size and complexity of nuclear power plant containment structures and the heterogeneity of Portland cement concrete make characterization of the degradation extent a difficult task. This paper examines the benefits of using time-frequency analysis with Synthetic Aperture Focusing Technique (SAFT). By using wavelet packet decomposition, the original ultrasound signals are decomposed into various frequency bands that facilitates highly selective analysis of the signal’s frequency content and can be visualized using the familiar SAFT image reconstruction algorithm.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Computer systems for annotation of single molecule fragments

There are provided computer systems for visualizing and annotating single molecule images. Annotation systems in accordance with this disclosure allow a user to mark and annotate single molecules of interest and their restriction enzyme cut sites thereby determining the restriction fragments of single nucleic acid molecules. The markings and annotations may be automatically generated by the system in certain embodiments and they may be overlaid translucently onto the single molecule images. An image caching system may be implemented in the computer annotation systems to reduce image processing time. The annotation systems include one or more connectors connecting to one or more databases capable of storing single molecule data as well as other biomedical data. Such diverse array of data can be retrieved and used to validate the markings and annotations. The annotation systems may be implemented and deployed over a computer network. They may be ergonomically optimized to facilitate user interactions.

59 BASIC BIOLOGICAL SCIENCES↗

Wall-Jet Evolution During Plume-Surface Interaction Using PLIF Imaging

Planar laser-induced fluorescence (PLIF) flow visualization was used to examine the spatial evolution for the wall-jet formed by an impinging supersonic jet in a large-scale vacuum environment. This canonical configuration is representative of the plume-surface interaction induced by a rocket exhaust plume impinging on the planetary surface at lunar-relevant and Martian-relevant environments. PLIF flow visualization of the very low-density environment (as low as ~0.006% of standard atmospheric density) was performed using seeded nitric oxide in a nitrogen flow at three test conditions. Two conditions are representative of the lunar environment, and one is representative of the Martian environment. The combined images from two simultaneous PLIF views were used to construct a 2D slice of the flowfield spanning approximately 150 mm in height (determined by the laser sheet) and 500 mm in width (determined by the camera views). The three test conditions showed different behavior for the wall-jet, largely due to the different levels of lifting above the surface and the appearance of a physical process similar to a Kelvin–Helmholtz instability for the Martian-relevant case, which appeared to create a dramatic expansion of the wall-jet height with increased radial distance.

PSI↗

Wall-Jet Evolution During Plume-Surface Interaction Using PLIF Imaging

Planar laser-induced fluorescence (PLIF) flow visualization was used to examine the spatial evolution for the wall-jet formed by an impinging supersonic jet in a large-scale vacuum environment. This canonical configuration is representative of the plume-surface interaction induced by a rocket exhaust plume impinging on the planetary surface at lunar-relevant and Martian-relevant environments. PLIF flow visualization of the very low-density environment (as low as ~0.006% of standard atmospheric density) was performed using seeded nitric oxide in a nitrogen flow at three test conditions. Two conditions are representative of the lunar environment, and one is representative of the Martian environment. The combined images from two simultaneous PLIF views were used to construct a 2D slice of the flowfield spanning approximately 150 mm in height (determined by the laser sheet) and 500 mm in width (determined by the camera views). The three test conditions showed different behavior for the wall-jet, largely due to the different levels of lifting above the surface and the appearance of a physical process similar to a Kelvin–Helmholtz instability for the Martian-relevant case, which appeared to create a dramatic expansion of the wall-jet height with increased radial distance.

PSI↗

Effect of color coding and subtraction on the accuracy of contrast echocardiography

BACKGROUND: Contrast echocardiography may be used to assess myocardial perfusion. However, gray scale assessment of myocardial contrast echocardiography (MCE) is difficult because of variations in regional backscatter intensity, difficulties in distinguishing varying shades of gray, and artifacts or attenuation. We sought to determine whether the assessment of rest myocardial perfusion by MCE could be improved with subtraction and color coding. METHODS AND RESULTS: MCE was performed in 31 patients with previous myocardial infarction with a 2nd generation agent (NC100100, Nycomed AS), using harmonic triggered or continuous imaging and gain settings were kept constant throughout the study. Digitized images were post processed by subtraction of baseline from contrast data and colorized to reflect the intensity of myocardial contrast. Gray scale MCE alone, MCE images combined with baseline and subtracted colorized images were scored independently using a 16 segment model. The presence and severity of myocardial contrast abnormalities were compared with perfusion defined by rest MIBI-SPECT. Segments that were not visualized by continuous (17%) or triggered imaging (14%) after color processing were excluded from further analysis. The specificity of gray scale MCE alone (56%) or MCE combined with baseline 2D (47%) was significantly enhanced by subtraction and color coding (76%, p<0.001) of triggered images. The accuracy of the gray scale approaches (respectively 52% and 47%) was increased to 70% (p<0.001). Similarly, for continuous images, the specificity of gray scale MCE with and without baseline comparison was 23% and 42% respectively, compared with 60% after post processing (p<0.001). The accuracy of colorized images (59%) was also significantly greater than gray scale MCE (43% and 29%, p<0.001). The sensitivity of MCE for both acquisitions was not altered by subtraction. CONCLUSION: Post-processing with subtraction and color coding significantly improves the accuracy and specificity of MCE for detection of perfusion defects.

Multicenter Study↗

Comparison of Magnetic Resonance Imaging and Computed Tomography for Breast Target Volume Delineation in Prone and Supine Positions

Purpose: To determine whether T2-weighted MRI improves seroma cavity (SC) and whole breast (WB) interobserver conformity for radiation therapy purposes, compared with the gold standard of CT, both in the prone and supine positions. Methods and Materials: Eleven observers (2 radiologists and 9 radiation oncologists) delineated SC and WB clinical target volumes (CTVs) on T2-weighted MRI and CT supine and prone scans (4 scans per patient) for 33 patient datasets. Individual observer's volumes were compared using the Dice similarity coefficient, volume overlap index, center of mass shift, and Hausdorff distances. An average cavity visualization score was also determined. Results: Imaging modality did not affect interobserver variation for WB CTVs. Prone WB CTVs were larger in volume and more conformal than supine CTVs (on both MRI and CT). Seroma cavity volumes were larger on CT than on MRI. Seroma cavity volumes proved to be comparable in interobserver conformity in both modalities (volume overlap index of 0.57 (95% Confidence Interval (CI) 0.54-0.60) for CT supine and 0.52 (95% CI 0.48-0.56) for MRI supine, 0.56 (95% CI 0.53-0.59) for CT prone and 0.55 (95% CI 0.51-0.59) for MRI prone); however, after registering modalities together the intermodality variation (Dice similarity coefficient of 0.41 (95% CI 0.36-0.46) for supine and 0.38 (0.34-0.42) for prone) was larger than the interobserver variability for SC, despite the location typically remaining constant. Conclusions: Magnetic resonance imaging interobserver variation was comparable to CT for the WB CTV and SC delineation, in both prone and supine positions. Although the cavity visualization score and interobserver concordance was not significantly higher for MRI than for CT, the SCs were smaller on MRI, potentially owing to clearer SC definition, especially on T2-weighted MR images.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Calibration, Reconstruction, and Rendering of Cylindrical Millimeter-Wave Image Data

Cylindrical millimeter-wave imaging systems and technology have been under development at the Pacific Northwest National Laboratory for many years. This technology has been commercialized, and systems are currently being deployed widely across the United States and internationally. These systems are effective at screening for concealed items of all types, however, new sensor designs, image reconstruction techniques, and image rendering algorithms, could potentially improve performance. At PNNL, a number of specific techniques have been developed recently to improve cylindrical imaging methods including wideband techniques, combining data from full 360 degree scans, polarimetric imaging techniques, calibration methods, and 3-D data visualization techniques. Many of these techniques exploit the three-dimensionality of the cylindrical imaging technique by optimizing the depth resolution of the system and using this information to enhance detection. Other techniques, such as polarimetric methods, exploit scattering physics of the millimeter-wave interaction with concealed targets on the body. In this paper, calibration, reconstruction, and three-dimensional rendering techniques will be described that optimize the depth information in these images and the display of the images to the operator.

concealed-weapon detection↗

Seed-based transrectal ultrasound-fluoroscopy registration method for intraoperative dosimetry analysis of prostate brachytherapy

Prostate brachytherapy is an effective treatment option for early-stage prostate cancer. During a prostate brachytherapy procedure, transrectal ultrasound (TRUS) and fluoroscopy imaging modalities complement each other by providing good visualization of soft tissue and implanted seeds, respectively. Therefore, the registration of these two imaging modalities, which are readily available in the operating room, could facilitate intraoperative dosimetry, thus enabling physicians to implant additional seeds into the underdosed portions of the prostate while the patient is still on the operating table. It is desirable to register TRUS and fluoroscopy images by using the seeds as fiducial markers. Although the locations of all the implanted seeds can be reconstructed from three fluoroscopy images, only a fraction of these seeds can be located in TRUS images. It is challenging to register the TRUS and fluoroscopy images by using the identified seeds, since the correspondence between them is unknown. Furthermore, misdetection of nonseed structures as seeds can lead to the inclusion of spurious points in the data set. We developed a new method called iterative optimal assignment (IOA) to overcome these challenges in TRUS-fluoroscopy registration. By using the Hungarian method in an optimization framework, IOA computes a set of transformation parameters that yield the one-to-one correspondence with minimum cost. We have evaluated our registration method at varying noise levels, seed detection rates, and number of spurious points using data collected from 25 patients. We have found that IOA can perform registration with an average root mean square error of about 0.2 cm even when the seed detection rate is only 10%. We believe that IOA can offer a robust solution to seed-based TRUS-fluoroscopy registration, thus making intraoperative dosimetry possible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

PhytoPET, PhytoBeta and PhytoSPECT: Radioisotope Imaging Systems Being Developed for Plant Biology Research

The Radiation Detector and Imaging Group at Thomas Jefferson National Accelerator Facility (Jefferson Lab) is developing radioisotope imaging systems designed and constructed to facilitate plant biology studies at the Duke University Phytotron. The imaging systems utilize nuclear medicine imaging methodologies used in positron emission tomography (PET) and single photon emission computed tomography (SPECT) but designed specifically for plant biology. The range of plant shapes and the environmental conditions in plant growth chambers pose a technological challenge. Description: Jefferson Lab is collaborating with the Duke University Phytotron and the Triangle Universities Nuclear Laboratory (TUNL) in the construction and operation of PhytoPET and PhytoBeta (for direct beta particle detection) for plant and/or microbe imaging. The TUNL tandem Van de Graaff accelerator (maximum terminal voltage of 10 MV) has been used to generate 11C and 13N for plant biology research. The PhytoPET and PhytoBeta have been used with 11C as a 11CO2 tracer for plant ecophysiology imaging with corn, poplar, oak and barley utilizing technologies developed for nuclear physics research and nuclear medicine. The imaging detectors are based on position sensitive photomultiplier tubes coupled to scintillators. Additionally, the collaboration is investigating a methodology using single photon emitting radioisotope tracers for imaging the distribution of molecular compounds of interest in the rhizosphere, the interface between root and soil, without disturbing the root or soil habitat. Plans are underway to develop a single photon emission computed tomography (SPECT) system (PhytoSPECT) to image the bio-distribution of fungi in association with a host plant's roots. In addition to a description of the technology an overview will be given of the application of PhytoPET, PhytBeta and PhytoSPECT to plant biology research at Duke University. Conclusions: We have developed and used radioisotope imaging technologies based on PET and SPECT to visualize plant function in changing environments. There are many opportunities to provide radioisotope based imaging tools for plant ecophysiology imaging. Keywords: radioisotope detection, plant biology, carbon-11, accelerator produced isotopes

Weisenberger, Andrew↗

Imaging of molecular hydrogen and oxygen by single and two-photon fluorescence using laser and flashlamp sources

Two flow visualization techniques, i.e., simultaneous two-dimensional fluorescence imaging of H2 and O2 in a diffusion flame, and quasi-linear fluorescence imaging of O2, are presented. The first uses an injection-locked argon-fluoride excimer laser and a partial overlap of a two-photon ground state absorption in H2 with a single photon absorption from a vibrational level in O2. The second uses a simple, high-intensity ultraviolet flashlamp which provides a flux of photons in the 180-195 nm range, sufficient to produce a quasi-one-dimensional fluorescence image of hot/room temperature oxygen. Both techniques do not require that a seed material be introduced into the flow, they can image major flow constituents, and provide an instantaneous snapshot of the flow.

Diskin, Glenn S.↗

Conceptual Design of a Test Section for a Cryogenic Transfer Line Experiment

This project presents the development of a comprehensive computer-aided design (CAD) model for the Transfer Line test section, which is an upcoming test module for the Flow Boiling and Condensation Experiment (FBCE) aboard the International Space Station. The FBCE aims to serve as the primary platform to study two-phase flow in microgravity, and the Transfer Line module aims to utilize its existing hardware to study cryogenic chilldown; a critical component of cryogenic propellant transfer in space. The CAD model was created using SolidWorks software and includes the test section’s main components: a heat transfer line, a flow visualization line, insulation, high-speed visible imaging, and infrared imaging. The heat transfer line primarily consists of a stainless steel tube that will be heated via Joule heating. The flow visualization line consists of segmented Indium-Titanium-Oxide coated sapphire tubes, which allow for visualization of flow regimes by high-speed and infrared cameras, similar thermal properties as the stainless steel tube, and Joule heating via the ITO coating resistance. Polyether Ether Ketone was used to insulate and encapsulate the two sections. High-speed visible imaging and infrared imaging were also incorporated to view the propagation of fluid during inverted annular flow and map out the thermal profile of the ITO-coated sapphire tube. This model serves as the guiding concept design for the Transfer Line project and will assist the project team during future safety reviews and concept design reviews. Overall, this work is significant in two-phase flow research and offers a promising path towards an established facility for cryogenic transfer line research in microgravity.

Flow boiling↗