Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “grid storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Power Electronic Hardware-in-the-Loop (PE-HIL): Testing Individual Controllers in Large-Scale Power Electronics Systems

Large power electronics systems like multi-port autonomous reconfigurable solar power plant (MARS) are increasingly being researched upon to integrate emerging energy sources. MARS connects photovoltaic (PV) systems and energy storage systems (ESSs) to high-voltage direct current (HVdc) links/grids and high-voltage alternating current (ac) transmission grids. As these large power electronics systems incorporate complex hierarchical control systems that are close-by and communicate fast, the control systems require an unique power electronic hardware-in-the-loop (PE-HIL) real-time architecture to evaluate individual controllers. In this paper, a PE-HIL real-time architecture is proposed to evaluate one of the hundreds to thousands of digital signal processors (DSPs) that are a part of the complex hierarchical control system. The DSP connects to a central processing unit (CPU) and a field programmable gate array (FPGA) that form a part of the upper levels of the control system. The DSP is part of the lower level of the control system. The proposed PE-HIL architecture is tested and evaluated. Preliminary test results are presented to showcase the concept.

Debnath, Suman↗

Optimal Energy Dispatch Controller for Fuel Cell-Integrated Multi-Zone Building

Stationary fuel cells provide potential opportunities for energy savings when integrated with buildings. Through smart dispatch of both electrical power and heat generated by the fuel cells and managing the building loads, the buildings can achieve more efficient operation. In this paper, we develop an optimal energy dispatch controller to operate a fuel cell-integrated building. The controller leverages the inherent thermal storage and the dispatchable fuel cell to reduce its operating cost and to allow the building to participate in grid services. The proposed controller is implemented on two types of commercial buildings, a large office building and a large hotel, and the effectiveness of the controller is demonstrated through simulations. The results also indicate that the potential saving varies significantly with different system parameters, including season, fuel prices, and equipment sizing, which provide helpful insights for building operators and other stake holders.

39 EE - Hydrogen and Fuel Cell Technologies (EE-3F↗

Grid Value Propositions for Tidal Generation Resources - a Temporal Analysis

As the energy sector experiences a paradigm shift towards cleaner and greener generation sources, the need for evaluating the applicability of marine energy for grid-based applications has intensified. This is because marine energy (ocean, wave and tidal) may be utilized to provide unique benefits to electric grid operations, especially in conjunction with other established renewable technologies (such as wind and solar) or technologies like energy storage. In this work, we focus our attention on some specific characteristics of two types of marine energy resources i.e. tidal and ocean current based resources. Specifically, we perform a comprehensive temporal analysis using a suite of metrics on resource data to characterize the inherent predictability of the resource across various time scales of interest. We also investigate the correlation of tidal power generation profiles with energy demand and comment on the effectiveness of having such resources in the overall generation portfolio.

Bhattacharya, Saptarshi↗

Durability tests of a five-centimeter diameter ion thruster system.

A modified Hughes SIT-5 system is being tested for durability at the Lewis Research Center. As of Oct. 1, 1972, the thruster subsystem has logged over 8000 hours of operation. The initial 2023 hours were run with a translating screen thrust vector grid. The thruster is currently operating with an electrostatic type vector grid. Profiles and maps taken at widely separated intervals show that performance and operating characteristics have remained essentially constant. Overall efficiency is about 32 per cent and power to thrust ratio is 170 watts per millipound at a specific impulse of 2500 seconds. Telescopic examination of the vector grid shows some sputtering erosion due to charge exchange and direct impingement ions. An independent test of the propellant storage and cathode-isolator-vaporizer subsystem has demonstrated good reliability under simulated thruster operating conditions.

Nakanishi, S.↗

A rapid numerical solution to subsonic flow over planar and axisymmetric profiles at an angle of attack of 0 deg

A numerical solution is presented for the incompressible flow over thin planar and axisymmetric profiles at an angle of attack of 0 degrees. The method uses a finite-difference field solution to the governing equation with a Gauss-Seidel successive overrelaxation scheme. However, the use of a simple Cartesian grid system restricts this method to slender profiles. Results are presented for a cambered airfoil, airfoil in wall effect (two-dimensional flowthrough inlet), body of revolution, and flowthrough nacelle. A computer program is presented which can be used for any of the previously mentioned cases with simple input changes. Results for compressible flow are available with the use of the appropriate two-dimensional or axisymmetric compressibility corrections. Computational time for a typical field calculation of 3000 grid points and 200 cycles through the field is less than 1 minute with less than 50,000 octal storage on the Control Data Corporation 6600 computing system.

Mascitti, V. R.↗

Direct numerical simulation of sheared turbulent flow

The summer assignment to study sheared turbulent flow was divided into three phases which were: (1) literature survey, (2) computational familiarization, and (3) pilot computational studies. The governing equations of fluid dynamics or Navier-Stokes equations describe the velocity, pressure, and density as functions of position and time. In principle, when combined with conservation equations for mass, energy, and thermodynamic state of the fluid a determinate system could be obtained. In practice the Navier-Stokes equations have not been solved due to the nonlinear nature and complexity of these equations. Consequently, the importance of experiments in gaining insight for understanding the physics of the problem has been an ongoing process. Reasonable computer simulations of the problem have occured as the computational speed and storage of computers has evolved. The importance of the microstructure of the turbulence dictates the need for high resolution grids in extracting solutions which contain the physical mechanisms which are essential to a successful simulation. The recognized breakthrough occurred as a result of the pioneering work of Orzag and Patterson in which the Navier-Stokes equations were solved numerically utilizing a time saving toggling technique between physical and wave space, known as a spectral method. An equally analytically unsolvable problem, containing the same quasi-chaotic nature as turbulence, is known as the three body problem which was studied computationally as a first step this summer. This study was followed by computations of a two dimensional (2D) free shear layer.

Harris, Vascar G.↗

Building Battery Energy Storage System Performance Data into an Economic Assessment

Economic assessments of battery energy storage systems (BESSs) rely on optimal dispatch methods to capture temporal interdependency of BESS operations and coupling among different grid applications. Many existing BESS economic assessment studies are based on a simplified first-order scalar model using BESS nameplate numbers. Such a method cannot accurately capture varying capabilities and nonlinear dynamics of a BESS, leading to inaccurate assessment results. This paper presents a practical implementation of performance data into the economic assessment of the BESSs recently developed within the Snohomish Public Utility District system in Washington State. Extensive testing conducted over multiple seasons is used to assess the technical performance and develop high-fidelity models of the BESSs. A dynamic programming algorithm is proposed to optimally dispatch the BESSs and assess the potential benefits from stacked value streams. The proposed method can be adapted for the economic assessment of other BESSs with different applications.

Wu, Di↗

Working With the Hydropower Program in the U.S. Department of Energy’s Water Power Technologies Office

The Hydropower Program at the U.S. Department of Energy’s (DOE) Water Power Technologies Office (WPTO) supports research, development, demonstration, and commercial activities to: • Advance transformative, cost-effective, reliable, and environmentally sustainable hydropower and pumped storage hydropower technologies. • Better understand and capitalize on opportunities for these technologies to support the nation’s rapidly evolving grid. • Improve energy-water infrastructure and security.

hydropower, hydropower facts, hydropower statistic↗

A Graph-Net with Node Embeddings to Detect False Data Injection Attacks in Photovoltaic Systems

Distributed energy resources (DER) contribute to the operational stability of the larger power grid both at utility-scale as well as commercial and residential scales in aggregated forms. These DER in-turn are susceptible to increasing cyber threats. An adversary can plug into the same local network that a field photovoltaic (PV) system uses to interconnect its data loggers and inverters and manipulate certain measurements collected from the network or trick existing irradiance and inverter readings through false data injection attacks (FDIA). Control routines that rely on these measurements can propagate the false data, impacting critical decisions that result in a suboptimal operation or even cause intentional harm leading to inverter-tripping or unscheduled loads that need to be shed. To detect FDIA in PV systems, the paper introduces an attention-based graph neural network with node embeddings and applied it to a simple prototypical DC-coupled microgrid with PV, energy storage, and load. The algorithm shows a detection accuracy of up to 98.95%. The proposed FDIA detection technique will provide micro-grid operators with an effective method to safeguard their systems, guaranteeing the secure and reliable operation.

Parvez, Imtiaz [Utah Valley University]↗

Deadband Voltage Control and Power Buffering for Extreme Fast Charging Station

Voltage fluctuation is one of the most common challenges that electric vehicle charging station (EVCS) may introduce to the power grid. Local reactive power compensation (Q-compensation) capability of bi-directional electric vehicle (EV) chargers can mitigate the steady-state voltage violations caused by the EV charging itself or changes in the neighboring loads. Power buffering, using energy storage system (ESS), can be utilized to address the voltage transients (sags and swells) as a result of EV charging at the EVCS. To address PI controller’s ‘hunting’ issue, this paper proposes a Q-sign triggered deadband voltage control (V-control) method at the point of common coupling (PCC). In addition, to ensure the ramp rate of EV charging is within the allowable limits set forth by the grid code, a ramp rate control is proposed that uses the ESS as a ‘power buffer’. Lastly, different from most reported work in the literature where no explicit limit of the power electronic converters (PECs) is considered, this work considers a reasonable apparent power capacity limit of the PECs when achieving the V-control. This limit also affects the amount of active power that can be obtained from the grid, and subsequently may require ESS to function as ‘load sharing’ device to provide supplemental active power to satisfy EV load. A case study simulated in MATLAB (interfaced with PLECS) is presented to demonstrate the effectiveness of the proposed approaches for EVCS operation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cost-Effective Thermally Activated Building Systems to Support a Power Grid System With High Penetrations Of As-Available Renewable Energy Resources

With a goal to reduce the energy cost for building operation as well as to support renewable energy sources (RES) for the power grid reliability, quality, resilience, and dispatchability, this project developed and demonstrated a novel thermally activated building envelope system that integrates Phase Change Material (PCM)-based Thermal Energy Storage (TES) and the hydronic activation into the building envelope. The main objectives of this study are: 1) to design and laboraorty-test a novel thermally activated building envelope system that integrate PCM-based TES and the hydronic activation into building envelope, and 2) to exploit this new system to significantly reduce the energy cost of operating buildings and manage and support renewable energy sources (RES), e.g., solar and wind for the power grid reliability, quality, resilience, and dispatchability. To achieve the project objectives, a new low-cost, fire-retardant PCM packaging technology (CenoPCM) was developed specifically for high-volume building applications.

25 ENERGY STORAGE↗

Managing the techno-economic impacts of partial string failure in multistring energy storage systems

The role of energy storage systems (ESSs) is becoming increasingly important for today’s electric power systems. Unavailability of an ESS assigned to critical grid services may cause unwanted disruption of those services and hence, may have a significant techno-economic impact. Like any physical equipment, an ESS is vulnerable to various types of faults. Failure of one or more strings in a multistring ESS does not have to be the cause of shutting down the entire ESS. It can still operate with a partial number of strings and continue providing critical services to the grid, if there are no reliability or safety issues and is acceptable under applicable standards. However, it is important to make sure that the control strategies are adaptable to the changes in ESS capacity caused by failed strings. Also, depending on the previous operation and type of failure, the reallocation of duty cycle burden among available strings could be non-uniform. These complexities suggest that mitigation of the impact of partial failure in multistring ESSs is not trivial and needs careful consideration. This is the topic of this paper. The proposed work investigates the impact of partial failure of a large multistring ESS on the assigned service and develops strategies to adjust the ESS control duty cycles for reducing such impacts. In doing so, the paper proposes a novel two-stage framework that plans for the multistring failure using robust optimization theory and then adjusts in real-time using a rule-based algorithm, based on the real-time information on the power availability of the string. Illustrations provided in this work are based on frequency regulation use-case, which is a common application for many utility-scale ESSs. A 750 kilowatt (kW)/1500 kilowatt-hour (kWh) 3-string ESS is used for the demonstration in this work and the efficacy of the proposed method is demonstrated and compared against methods that do not incorporate string failure in their strategy. In particular, here we show that revenue loss of 93% can be incurred when partial string failure is not included in operation and planning. These losses in revenue are reduced by 60% with the proposed method.

25 ENERGY STORAGE↗

Technical Performance of Refractory Liners for Molten Chloride Salt Thermal Energy Storage Systems

A chloride-based molten-salt system that uses a ternary blend of MgCl2/KCl/NaCl is investigated to provide higher temperature thermal energy storage capability. Despite higher thermal stability, molten chlorides present several unique challenges, including the design of internal refractory-ceramic liners to prevent the corrosion and thermal stress of alloy tank shells. This work discusses issues and potential solutions related to containment of molten chloride salt, specifically the optimization of the refractory material at the molten salt interface (hot face). The down-selected hot face candidate limits permeation of salt through the material and forms a highly stable secondary surface phase in equilibrium with the molten salt. A mortar is created using the corrosion resistant hot face brick. Brick and mortar composite are subjected to mechanical stress/strain analysis, in order to calculate composite material properties and better inform thermomechanical models. The U.S. Department of Energy Generation 3 (DOE Gen3) program seeks to develop higher efficiency CSP plants that can provide cost-competitive, flexible power in the U.S. electric grid. The proposed Gen3 Liquid Pathway CSP plant closely resembles the configuration of current nitrate salt power towers with two-tank storage (Gen2). The differences between Gen2 and Gen3 include the types of compatible materials used in salt storage tank construction. Stainless steel loses strength at Gen3 temperatures, and although nickel superalloys would be capable of withstanding sustained high temperatures, these materials are prohibitively expensive at scale. Uninsulated tank shells also pose a significant risk as common steels are highly susceptible to chemical attack from molten chloride salt. To address these concerns, refractory-ceramic based containment materials are proposed to line the inside of the hot and cold storage tanks. In doing so, stainless or carbon steel shells may be used in construction depending on the level of insulation provided. The composition of the internal liner requires careful consideration to maximize the efficacy of multiple parameters including corrosion resistance, strength at operating temperature, durability, and cost. This is particularly true for the material at the interface with the salt, known as the "hot face", which is responsible for protecting the insulating layers between the tank shell and the hot face brick layer. The molten salt in this system is superheated over 300 °C above its freeze temperature. Therefore, unlike other industrial processes which use refractory-lined vessels, it is not expected that a freeze plane will develop in the hot face. Therefore, the hot face must be designed to withstand chemical corrosion and inhibit permeation of molten salt into the insulating layers. A down selection was performed to identify a hot face candidate best equipped to maintain thermal, mechanical, and chemical integrity when exposed to molten salt over extended periods of time. Long-duration chemical capability experiments were conducted with the down selected hot face refractory fully immersed in molten chloride salt for up to 3000 hours. The average salt penetration does not exceed 100 microns. When extrapolated to 20 and 30 years of continuous exposure, the expected salt penetration depth is approximately 2.0 mm and 2.9 mm, respectively. A magnesium-rich secondary phases develops at the salt/refractory interface. X-ray diffraction identifies the material as forsterite (Mg2SiO4), which is reported to form synthetically in molten chloride salt solutions. These results suggest the selected hot face will adequately inhibit salt permeation. While there is optimism that the hot face brick will inhibit salt permeation, mortar joints are typically the weakest point of a refractory brick liner. From a thermochemical perspective, differing thermal expansion coefficients may result in the mortar and brick to grow independent of each other, creating gaps through which molten salt can penetrate. To address this issue, NREL has developed an in-house mortar composed of the down selected hot face brick that has been shown to be compatible with the salt. Compressive stress/strain analyses have been performed on the brick/ mortar composites to generate stress/strain curves. Modulus of elasticity and Poisson's ratio of the composite may be calculated from the stress/strain curves, in order to provide more representative data to finite element mechanical models for accurate approximation of stress on the tank shell and the amount of thermal expansion expected within the tank liner.

41 EE - Solar Energy Technologies Office (EE-4S)↗

GMLC Survey of Distributed Energy Resource Interconnection and Interoperability Standards

This document reports on the Grid Modernization Laboratory Consortium effort to identify gaps in standards for the interconnection and interoperability of distributed energy resources (DERs). The project extended a 3-year period from 2017 to 2019. Under the work plan, the team identified standards and test procedures related to interconnection and interoperability, grouped under the broad headings of their primary applicable technology domain: automotive, responsive loads, photovoltaic inverters, inverter-based energy storage, machine-based DERs, and microgrids. The team then conducted a gap analysis by comparing the current standards to the expected future requirements needed for specific grid services. Overall, gaps could be any activity needed to harmonize requirements among standards development organizations, minimize conflicting requirements among technology domains, or streamline conformance test procedures.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid Value Investigation of Medium-Voltage Back-to-Back Converters: Preprint

This paper presents the work which investigates the value that the medium voltage back to back (MVB2B) converter can bring to the grid, through two potential applications: voltage regulation powered by the reactive power adjustment function, and the distributed energy resource (DER) adoption enhancement powered by the quantitative power transfer function. Two groups of distribution systems have been prepared for the value investigation, including IEEE 123-bus system for voltage regulation study and two utility provided realistic distribution systems for DER adoption enhancement study. The analysis results have demonstrated that the MVB2B converter can bring significant value to the grid through the two aforementioned applications. Particularly, with MVB2B converter transferring power between two feeders, a substantial amount of backfeeding solar power can be avoided, and the size of the energy storage which is used to store the extra solar power can be significantly reduced.

28 EE - Advanced Manufacturing Office (EE-5A)↗

The Best of Both Worlds: Combined Thermal and Battery Storage for Widespread Building Decarbonization

To meet 2050 decarbonization targets, widespread building electrification is a critical complement to clean power generation. Behind-the-meter storage (BTMS) (e.g., battery electric energy storage [EES] and thermal energy storage [TES]) integrated with buildings or building end uses to store and supply energy at optimal times can minimize burdens associated with operation, planning, and upgrades to the electrical grid sometimes triggered by building electrification. Such BTMS systems can serve the dual purpose of providing enhanced resilience at the building and grid level, and support the deployment of renewable generation needed for wide-scale decarbonization. While TES can cost-effectively shed and shift thermal loads, it cannot generally backup or shift non-thermal building end uses. EES, by contrast, is more expensive, but applicable to all end uses (i.e., thermal and electrical loads). Combined together, these storage systems can be traded off against one another to perform optimally in meeting demand flexibility, decarbonization goals, and energy resilience of the buildings at a lower total system cost. This paper proposes a framework to define BTMS benefits, provides four illustrative electrification scenarios using TES and EES, and discusses the combined TES/EES benefits with building energy modeling results. The paper also highlights potential barriers to adoption of BTMS and a path forward.

buildings↗

Long-duration Energy Storage Technology Analysis and Development

This project develops a new low-cost and flexible long-duration energy storage (LDES) technology based on simultaneous regeneration technology. In lieu of the technology development, the project team also conducts a complete cost analysis for LDES based on various currently available technologies, as well as grid economic and environmental benefits analysis for LDES. There are three tasks in this project: Task 1. Fe-H2 flow cell fabrication, testing, demonstration; Task 2. Dynamic modeling, simulation and control architecture of power system; Task 3. Cost and grid analysis.

25 ENERGY STORAGE↗

Battery Energy Storage System (BESS) Licensing and Permitting [Slides]

This presentation provides an overview of the licensing, permitting, and regulatory frameworks governing Battery Energy Storage Systems (BESS) across multiple international contexts. It outlines foundational permitting considerations - including safety standards, siting requirements, regulatory and environmental obligations, and interconnection processes - alongside typical pathways for installation, approval, and inspection. The presentation summarizes key technical standards such as NFPA 855 and IEEE guidelines, and emphasizes best practices for safe and effective deployment. A series of detailed case studies from South Africa, Chile, Mexico, Brazil, Costa Rica, Honduras, and the Dominican Republic illustrates how different countries structure approval authority, evaluate environmental impacts, and integrate BESS into national grid systems. The deck concludes with insights on emerging challenges, including evolving regulatory frameworks, financial viability, and the need for pricing mechanisms that accurately value storage services.

24 POWER TRANSMISSION AND DISTRIBUTION↗