Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “grid stability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Convergence results for pseudospectral approximations of hyperbolic systems by a penalty type boundary treatment

A new method of imposing boundary conditions in the pseudospectral approximation of hyperbolic systems of equations is proposed. It is suggested to collocate the equations, not only at the inner grid points, but also at the boundary points and use the boundary conditions as penalty terms. In the pseudo-spectral Legrendre method with the new boundary treatment, a stability analysis for the case of a constant coefficient hyperbolic system is presented and error estimates are derived.

Funaro, Daniele↗

Retention of Sputtered Molybdenum on Ion Engine Discharge Chamber Surfaces

Grit-blasted anode surfaces are commonly used in ion engines to ensure adherence of sputtered coatings. Next generation ion engines will require higher power levels, longer operating times, and thus there will likely be thicker sputtered coatings on their anode surfaces than observed to date on 2.3 kW-class xenon ion engines. The thickness of coatings on the anode of a 10 kW, 40-centimeter diameter thruster, for example, may be 22 micrometers or more after extended operation. Grit-blasted wire mesh, titanium, and aluminum coupons were coated with molybdenum at accelerated rates to establish coating stability after the deposition process and after thermal cycling tests. These accelerated deposition rates are roughly three orders of magnitude more rapid than the rates at which the screen grid is sputtered in a 2.3 kW-class, 30-centimeter diameter ion engine. Using both RF and DC sputtering processes, the molybdenum coating thicknesses ranged from 8 to 130 micrometers, and deposition rates from 1.8 micrometers per hour to 5.1 micrometers per hour. In all cases, the molybdenum coatings were stable after the deposition process, and there was no evidence of spalling of the coatings after 20 cycles from about -60 to +320 C. The stable, 130 micrometer molybdenum coating on wire mesh is 26 times thicker than the thickest coating found on the anode of a 2.3 kW, xenon ion engine that was tested for 8200 hr. Additionally, this coating on wire mesh coupon is estimated to be a factor of greater than 4 thicker than one would expect to obtain on the anode of the next generation ion engine which may have xenon throughputs as high as 550 kg.

Sovey, James S.↗

Model Validation for Propulsion - On the TFNS and LES Subgrid Models for a Bluff Body Stabilized Flame

This paper summarizes the reacting results of simulating a bluff body stabilized flame experiment of Volvo Validation Rig using a releasable edition of the National Combustion Code (NCC). The turbulence models selected to investigate the configuration are the sub-grid scaled kinetic energy coupled large eddy simulation (K-LES) and the time-filtered Navier-Stokes (TFNS) simulation. The turbulence chemistry interaction used is linear eddy mixing (LEM).

Flame↗

Development of Three-Dimensional Flow Code Package to Predict Performance and Stability of Aircraft with Leading Edge Ice Contamination

In the work reported herein, a simplified, uncoupled, zonal procedure is utilized to assess the capability of numerically simulating icing effects on a Boeing 727-200 aircraft. The computational approach combines potential flow plus boundary layer simulations by VSAERO for the un-iced aircraft forces and moments with Navier-Stokes simulations by NPARC for the incremental forces and moments due to iced components. These are compared with wind tunnel force and moment data, supplied by the Boeing Company, examining longitudinal flight characteristics. Grid refinement improved the local flow features over previously reported work with no appreciable difference in the incremental ice effect. The computed lift curve slope with and without empennage ice matches the experimental value to within 1%, and the zero lift angle agrees to within 0.2 of a degree. The computed slope of the un-iced and iced aircraft longitudinal stability curve is within about 2% of the test data. This work demonstrates the feasibility of a zonal method for the icing analysis of complete aircraft or isolated components within the linear angle of attack range. In fact, this zonal technique has allowed for the viscous analysis of a complete aircraft with ice which is currently not otherwise considered tractable.

Aircraft icing↗

Defining a Platform Approach and Market Participation: Data Driven Business Models for Solid State Transformer-Based Synthetic Inertia and Voltage Stability Controls (CRADA Final Report, Project 1, Mod 1)

The primary objective of this project is to determine the incremental value created with the medium voltage solid-state transformer (MV SST) technology to different stakeholders in view of the updated DER grid regulations. This includes studying the benefits of the MV SST technology in a range of use cases for EV and DER penetration including (1) “corridor charging” for EVs and (2) solar plus storage (FERC 2222). The potential customers of this technology include utilities for EV charging, DER installers who must meet utility interconnection requirements, balancing authorities, and DER aggregators. The traditional transformers on the grid could be a limiting factor for the EV-grid integration as the distribution transformers were not designed to handle the dynamic and fluctuating EV charging loads. Thus, the issues such as voltage fluctuations, increased losses and reduced efficiency [1] can negatively impact the grid operation. To address these challenges, transformers with flexibility and adaptability become imperative to meet the evolving energy demands. In this regard, the concept of Medium Voltage Solid-State Transformers.

14 SOLAR ENERGY↗

Using Cloud-to-Ground Lightning Climatologies to Initialize Gridded Lightning Threat Forecasts for East Central Florida

Each morning, the forecasters at the National Weather Service in Melbourn, FL (NWS MLB) produce an experimental cloud-to-ground (CG) lightning threat index map for their county warning area (CWA) that is posted to their web site (http://www.srh.weather.gov/mlb/ghwo/lightning.shtml) . Given the hazardous nature of lightning in central Florida, especially during the warm season months of May-September, these maps help users factor the threat of lightning, relative to their location, into their daily plans. The maps are color-coded in five levels from Very Low to Extreme, with threat level definitions based on the probability of lightning occurrence and the expected amount of CG activity. On a day in which thunderstorms are expected, there are typically two or more threat levels depicted spatially across the CWA. The locations of relative lightning threat maxima and minima often depend on the position and orientation of the low-level ridge axis, forecast propagation and interaction of sea/lake/outflow boundaries, expected evolution of moisture and stability fields, and other factors that can influence the spatial distribution of thunderstorms over the CWA. The lightning threat index maps are issued for the 24-hour period beginning at 1200 UTC (0700 AM EST) each day with a grid resolution of 5 km x 5 km. Product preparation is performed on the AWIPS Graphical Forecast Editor (GFE), which is the standard NWS platform for graphical editing. Currently, the forecasters create each map manually, starting with a blank map. To improve efficiency of the forecast process, NWS MLB requested that the Applied Meteorology Unit (AMU) create gridded warm season lightning climatologies that could be used as first-guess inputs to initialize lightning threat index maps. The gridded values requested included CG strike densities and frequency of occurrence stratified by synoptic-scale flow regime. The intent is to increase consistency between forecasters while enabling them to focus on the mesoscale detail of the forecast, ultimately benefiting the end-users of the product. Several studies took place at the Florida State University (FSU) and NWS Tallahassee (TAE) for which they created daily flow regimes using Florida 1200 UTC synoptic soundings and CG strike densities from National Lightning Detection Network (NLDN) data. The densities were created on a 2.5 km x 2.5 km grid for every hour of every day during the warm seasons in the years 1989-2004. The grids encompass an area that includes the entire state of Florida and adjacent Atlantic and Gulf of Mexico waters. Personnel at the two organizations provided this data and supporting software for the work performed by the AMU. The densities were first stratified by flow regime, then by time in 1-, 3-, 6-, 12-, and 24-hour increments while maintaining the 2.5 km x 2.5 km grid resolution. A CG frequency of occurrence was calculated for each stratification and grid box by counting the number of days with lightning and dividing by the total number of days in the data set. New CG strike densities were calculated for each stratification and grid box by summing the strike number values over all warm seasons, then normalized by dividing the summed values by the number of lightning days. This makes the densities conditional on whether lightning occurred. The frequency climatology values will be used by forecasters as proxy inputs for lightning prObability, while the density climatology values will be used for CG amount. In addition to the benefits outlined above, these climatologies will provide improved temporal and spatial resolution, expansion of the lightning threat area to include adjacent coastal waters, and potential to extend the forecast to include the day-2 period. This presentation will describe the lightning threat index map, discuss the work done to create the maps initialized with climatological guidance, and show examples of the climatological CG lightning densities and frequencies of occurren based on flow regime.

Lambert, Winnie↗

Opportunities of Aqueous Manganese-Based Batteries with Deposition and Stripping Chemistry

Rechargeable aqueous manganese-based batteries have been attracting significant attention owing to their advantages of low cost, high safety, and ease of manufacturing, which are promising attributes for grid-scale energy storage applications. However, most traditional manganese-based batteries with solid-state conversion and intercalation reactions suffer from low capacity and poor long-term cycling stability. The recent novel storage mechanism based on cathode Mn 2+ /MnO 2 deposition/stripping chemistry has fundamentally tackled these issues, enabling a new generation of manganese-based batteries with superior electrochemical performance. Here, the recent advances in aqueous manganese-based batteries with the Mn 2+ /MnO 2 deposition/stripping chemistry are reviewed. Furthermore, a summary of the development of manganese-based batteries with different storage mechanisms is provided and new opportunities for the emerging Mn 2+ /MnO 2 chemistry in the latest generation are highlighted. Then, the current understanding of the Mn 2+ /MnO 2 charge storage mechanism and its potential in manganese-based batteries for large-scale energy storage applications is presented. Moreover, insights into opportunities and future directions for manganese-based batteries with the Mn 2+ /MnO 2 chemistry are proposed.

25 ENERGY STORAGE↗

Near-Busbar Degradation of Screen-Printed Metallization in Silicon Photovoltaic Modules

We study photovoltaic (PV) module degradation after extended accelerated stress testing including 2000 hours of damp heat followed by a current-injection procedure meant to stabilize defects linked to light-induced degradation. In addition to de-stabilization/recovery of light-induced defects, we observe severe series resistance due to loss of contact between the Si cell and near-busbar screen-printed metallization (i.e. grid finger delamination). Using scanning electron microscopy and energy dispersive x-ray spectroscopy on cell fragments cored from the module, we show poor contact is caused by a gap between the screen-printed Ag metallization and Si due to missing glass frit.

degradation↗

Lattice Boltzmann Equation On a 2D Rectangular Grid

We construct a multi-relaxation lattice Boltzmann model on a two-dimensional rectangular grid. The model is partly inspired by a previous work of Koelman to construct a lattice BGK model on a two-dimensional rectangular grid. The linearized dispersion equation is analyzed to obtain the constraints on the isotropy of the transport coefficients and Galilean invariance for various wave propagations in the model. The linear stability of the model is also studied. The model is numerically tested for three cases: (a) a vortex moving with a constant velocity on a mesh periodic boundary conditions; (b) Poiseuille flow with an arbitras~y inclined angle with respect to the lattice orientation: and (c) a cylinder &symmetrically placed in a channel. The numerical results of these tests are compared with either analytic solutions or the results obtained by other methods. Satisfactory results are obtained for the numerical simulations.

Bouzidi, MHamed↗

High-Order Hyperbolic Residual-Distribution Schemes on Arbitrary Triangular Grids

In this paper, we construct high-order hyperbolic residual-distribution schemes for general advection-diffusion problems on arbitrary triangular grids. We demonstrate that the second-order accuracy of the hyperbolic schemes can be greatly improved by requiring the scheme to preserve exact quadratic solutions. We also show that the improved second-order scheme can be easily extended to third-order by further requiring the exactness for cubic solutions. We construct these schemes based on the LDA and the SUPG methodology formulated in the framework of the residual-distribution method. For both second- and third-order-schemes, we construct a fully implicit solver by the exact residual Jacobian of the second-order scheme, and demonstrate rapid convergence of 10-15 iterations to reduce the residuals by 10 orders of magnitude. We demonstrate also that these schemes can be constructed based on a separate treatment of the advective and diffusive terms, which paves the way for the construction of hyperbolic residual-distribution schemes for the compressible Navier-Stokes equations. Numerical results show that these schemes produce exceptionally accurate and smooth solution gradients on highly skewed and anisotropic triangular grids, including curved boundary problems, using linear elements. We also present Fourier analysis performed on the constructed linear system and show that an under-relaxation parameter is needed for stabilization of Gauss-Seidel relaxation.

Mazaheri, Alireza↗

A New Approach for a Wider Class of Entropy Split Methods for Compressible Gas Dynamics and MHD

The high order entropy split methods of Sjögreen & Yee [1, 2] by entropy splitting of the compressible Euler (inviscid) flux derivatives for a thermally-perfect gas are based on Harten’s entropy function [3, 4, 5]. Their derivation takes advantage of the homogeneity property of Euler flux, symmetrizable Euler flux derivatives and energy-norm stability in conjunction with high order classical spatial central, DRP (dispersion relation-preserving) [6, 7, 8] or Padé (compact) spatial discretizations [9] with summation-by-parts (SBP) operators [10]. Our entropy split methods have been proven entropy conserving and stable [1, 11, 12]. Our proofs do not rely on a two-point numerical flux, but rather only a linear difference operator is required to derive these methods. To extend the entropy split method for the MHD, we used the Godunov symmetrizable non-conservative MHD form [12, 13, 14]. These high order entropy split methods not only preserve certain physical properties of the chosen governing equations but are also known to either improve numerical stability, and/or minimize aliasing errors in long time integration of turbulent flow computations without the aid of added numerical dissipation. In our previous published work, extensive error norm comparison with grid refinement was performed to show the high accuracy performance of these methods. These studies also showed how well the entropy split methods conserve the entropy, momentum and mass, and preserve the kinetic energy for long time integration of the various flows [1, 2, 12, 13, 14]. The objective of the present work is to use a new approach to obtain a wider class of entropy split methods consisting of a two-point numerical flux portion and a non-conservative portion in such a way that the homogeneity property of the compressible Euler flux is not required. For high order classical spatial central, DRP (dispersion relation-preserving) or Padé (compact) spatial discretizations, this new approach can be proven to be entropy conservative with conservative spatial dsicretizations while at the same time allowing a wider class of symmetrizable inviscid flux derivatives. We also use this generalization to derive an entropy split scheme that is entropy conserving for the equations of MHD without the homogeneity property using the Godunov symmetrizable ideal MHD formulation [15].

High Order Physical Preserving Methods↗

Detecting and Analyzing Power System Disturbances in PMU Data with the Open-Source Archive Walker Tool

As the number of Phasor Measurement Units (PMUs) deployed in power systems increases, so do the archives of synchrophasor measurements stored by utilities. Significant value can be extracted from these archives by using them to support studies such as frequency response analysis, small-signal stability analysis, and power plant model validation. To better enable utilities to perform these studies, the open-source Archive Walker tool was developed. This tool examines PMU data for grid disturbances and periods of interest. Once identified, the data can be further analyzed inside Archive Walker or exported to specialty tools. In this paper, the various disturbance detectors available in Archive Walker are described, and its interactions with other openly-available tools are highlighted.

Follum, James D.↗

A Novel Power-Hardware-in-the-Loop Interface Method for Grid-forming Inverter Systems: Preprint

Power Hardware-in-the-Loop (PHIL) simulation of grid-forming (GFM) inverter systems facilitates the testing of drastic scenarios like on-grid to off-grid transition, islanded microgrid operation without stiff grid etc. To the authors best knowledge, most of studies in literature are focused on PHIL simulation for grid-following inverter systems and only few studies are focused on GFM inverters and those are challenging and problematic especially for high-power applications. In this article, a novel PHIL simulation platform is proposed that enables interfacing of high-power GFM inverter systems. It proposes the concept of a virtual GFM inverter as a part of the proposed PHIL interface for GFM inverter. This addition of virtual GFM inverter in the PHIL interface expands the conventional Ideal Transformer Model (ITM) method and enables it to overcome the issues of instability of existing ITM methods. In the validation stage, a PHIL experiment is conducted on a 3-phase 480 V, 125 kVA GFM inverter system with proposed interfacing method. The results corroborates the fact that the proposed PHIL simulation method performs well and stable for GFM inverter system.

grid-forming inverters↗

Study of Geometric Porosity on Static Stability and Drag Using Computational Fluid Dynamics for Rigid Parachute Shapes

This paper explores use of computational fluid dynamics to study the e↵ect of geometric porosity on static stability and drag for NASA's Multi-Purpose Crew Vehicle main parachute. Both of these aerodynamic characteristics are of interest to in parachute design, and computational methods promise designers the ability to perform detailed parametric studies and other design iterations with a level of control previously unobtainable using ground or flight testing. The approach presented here uses a canopy structural analysis code to define the inflated parachute shapes on which structured computational grids are generated. These grids are used by the computational fluid dynamics code OVERFLOW and are modeled as rigid, impermeable bodies for this analysis. Comparisons to Apollo drop test data is shown as preliminary validation of the technique. Results include several parametric sweeps through design variables in order to better understand the trade between static stability and drag. Finally, designs that maximize static stability with a minimal loss in drag are suggested for further study in subscale ground and flight testing.

Greathouse, James S.↗

Design and Stability Analysis of Control System in Multiport Autonomous Reconfigurable Solar Power Plants (MARS)

The Multiport Autonomous Reconfigurable Solar Power Plant (MARS) is an integrated photovoltaic (PV) power generation and energy storage system (ESS), that is designed to connect to both alternating current (AC) transmission grids and high-voltage direct current (HVDC) links. It is a three-phase plant consisting of numerous components with a complex hardware and hierarchical control architecture. This paper presents an approach to decouple the multivariable system of MARS using a recursive reduced-order and boundary layer system methodology. This approach enables efficient computation of the control parameters for the Ll, L2, and L3 controllers. To validate the effectiveness of the proposed control strategy, cyclic tests in accordance with pre-defined performance criteria using controller Hardware-in-the-Loop (cHIL) experiments are conducted. The results demonstrate that the MARS system operates consistently under steady-state conditions. Furthermore, the dynamic response of the MARS system to various grid events is analyzed, underlining the resilience of MARS in presence of faults or loss of generation within the connected WECC system.

Xia, Qian↗

Adaptive Protection and Validated Models to Enable Deployment of High Penetrations of Solar PV (PV-MOD)

The availability and validation of various PV models in commercial tools differ, with some models not yet thoroughly validated for advanced inverter functionalities and reliable performance under weak system conditions. Many existing models do not fully incorporate new inverter control functions, which can affect system stability. The increasing deployment of solar PV and other inverter-based resources (IBRs), including distributed energy resources (DERs), is influencing the reliable operation of protection schemes in distribution systems and microgrids. Emerging adaptive protection schemes (APS) offer new opportunities for protecting these systems during varying configurations and DER operating conditions, though their demonstration and validation remain limited. Adaptive protection schemes face similar challenges, as they are typically designed for specific configurations. There is a growing need for tools and methodologies to streamline the deployment of adaptive protection for safe and reliable DER integration. The project main objective was to develop and validate high-fidelity generic models of solar PV facilities for stability, protection, EMT, and QSTS analyses. This objective was achieved, and these models can now be integrated into commercial software tools, enabling utilities, vendors, and developers to study high-penetration PV systems more confidently. The project also demonstrated advanced applications of these models, including the design and deployment of adaptive protection schemes in high-penetration field applications and microgrids, supporting grid safety and reliability. Several milestones were reached by the end of the project. A sophisticated inverter test plan was developed, and inverters representative of the North American marketplace were selected. EPRI and NREL tested various inverters, conforming to IEEE standards. Improvements were made to existing generic models of IBR units, IBR plants, and aggregated feeders for various analyses. The first generic electromagnetic transient (EMT) model for a solar PV plant was developed, conforming to IEEE Std 2800™-2022 and validated against laboratory measurements of a 2.2 MVA large-scale battery energy storage system (BESS) inverter. That model was then used to produce reference responses illustrating examples of validated and verified IBR plant models that pass or fail tests for technical minimum capability and performance as specified in the IEEE standard. The developed, tested, and validated generic models can be used for transmission planning, stability assessments, expansion planning, and evaluating potential future IBR interconnection requirements. They can also support interconnection screens and conformity assessments of IBR plants, including solar PV. The project significantly contributed to the ongoing standardization and model-based representation and verification of IBR responses. The project further addressed challenges of common distribution protection schemes with increasing deployment of DER by developing, validating, and demonstrating adaptive protection schemes (APS) that can improve the reliable and safe integration of DER into distribution systems. New APS were designed using improved DER models for three common distribution systems: a radial feeder, a meshed network, and a microgrid. Modeling and hardware-in-the-loop (HIL) testing of the APS were conducted, successfully showing their effectiveness and selectivity. Proof-of-concept field demonstration was achieved for two APS, i.e., one on a radial feeder and another one in a microgrid. Field demonstration could not be achieved for the APS on a meshed network, primarily due apprehension of one utility partner and also due to limited access to the protective algorithms in the network protectors. Guidelines developed from the lessons learned in the project lay out the general process followed in the design, installation, and commissioning of APS for various distribution systems. Distribution utility partners’ apprehension about field demonstration of the new APS were addressed—with varying success—by taking a stepped risk-management approach of modeling of a wide range of sensitivities first, performing in-depth proof-of-concept testing in the laboratory including HIL next, and finally deliberately implementing and commissioning the actual protection equipment and algorithms into parts of—or in parallel operation to—the three real distribution systems. Future work should include pilot projects that further show the acceptable performance of the developed APS before these schemes be rolled out more widely. Inclusion of both utility and original equipment manufacturers (OEMs) in future projects could increase chances of successful field demonstration. Despite challenges in achieving the field demonstration goal of the project for all three APS, the research significantly contributed to the innovation of adaptive protection solutions for scalable and reliable DER integration into distribution systems. This project significantly enhances the understanding of the impact of using appropriate inverter models on distribution and transmission (T&D) systems. By addressing the limitations of existing generic models, the project introduces high-fidelity models for stability, protection, electromagnetic transient (EMT), and quasi-static time series (QSTS) analyses. These models, integrated into commercial software tools, enable utilities, vendors, and developers to confidently study high-penetration PV systems. The project also demonstrates advanced applications, including adaptive protection schemes (APS) for distribution systems and microgrids, ensuring grid safety and reliability. The technical effectiveness and economic feasibility of the methods are evident through the development and validation of sophisticated inverter test plans and the selection of representative inverters. Testing by EPRI and NREL on retail, commercial, and utility-scale inverters, conforming to IEEE standards, underscores the robustness of the models. Improvements to existing generic models for various analyses further enhance their validity and applicability. The project also identifies gaps in common distribution protection schemes and designed new APS using improved DER models, demonstrating their effectiveness through modeling and hardware-in-the-loop (HIL) testing. The project’s benefits to the public are manifold. By advancing the standardization and model-based representation of IBR response, it supports transmission planning, stability assessments, and future IBR interconnection requirements. The generic models can facilitate better communication between transmission planners and developers, supporting expected IBR plant capability and performance. Additionally, the development of APS for radial feeders, meshed networks, and microgrids supports the integration of distributed energy resources (DERs) into distribution systems, enhancing grid reliability and safety. The project’s emphasis on thorough testing and simplicity in design ensures practical and scalable solutions for DER integration.

14 SOLAR ENERGY↗