Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “energy efficient”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Electrochemically Engineered, Highly Energy-Efficient Conversion of Ethane to Ethylene and Hydrogen below 550 °C in a Protonic Ceramic Electrochemical Cell

Ethylene is one of the largest building blocks in the petrochemical industry, mainly produced by steam cracking of ethane derived from naphtha or shale gas at high temperatures (>800 °C). Despite its technical maturity and economic competitiveness, the thermal steam cracking of ethane is highly energy-intensive. In this work, an electrochemically engineered direct conversion process of ethane to produce hydrogen and ethylene using a planar protonic ceramic membrane reactor with a bi-functional three-dimensional catalytic electrode is reported, with a single-pass ethane conversion of 40% and ethylene yield of 26.7% at 550 °C. Compared with the industrial ethane steam cracking, this method saves process energy input by 45.1% and improves process energy efficiency by 50.6%, based on comprehensive process simulation using Aspen Plus software. Further, steam electrolysis treatment under the solid oxide electrolysis cell mode can regenerate the system’s catalytic performance and significantly alleviate catalytic degradation by 74%, demonstrating high techno-economic viability.

bi-functional electrode↗

Software Cuts Homebuilding Costs, Increases Energy Efficiency

To sort out the best combinations of technologies for a crewed mission to Mars, NASA Headquarters awarded grants to MIT's Department of Aeronautics and Astronautics to develop an algorithm-based software tool that highlights the most reliable and cost-effective options. Utilizing the software, Professor Edward Crawley founded Cambridge, Massachussetts-based Ekotrope, which helps homebuilders choose cost- and energy-efficient floor plans and materials.

Source record↗

Retrofitting Vegas: Implementing Energy Efficiency in Two Las Vegas Test Homes

In 2009, the state of Nevada received nearly forty million dollars in Neighborhood Stabilization Funds from the Department of Housing and Urban Development. The purpose of this funding was to stabilize communities that have suffered from foreclosures and abandonment. In an effort to provide guidance to local officials and maximize how effectively this NSP funding is utilized in retrofitting homes, CARB provided design specifications, energy modeling, and technical support for the Building America Retrofit Alliance (BARA) team and its local partners - Better Building Performance, Nevada Energy Star Partners Green Alliance, and Home Free Nevada - for two retrofit test homes. One home was to demonstrate a modest retrofit and the other a deep energy retrofit. Through this project, CARB has provided two robust solution packages for retrofitting homes built in this region between the 1980s and early 1990s without substantially inconveniencing the occupants. The two test homes, the Carmen and Sierra Hills, demonstrate how cost-effectively energy efficient upgrades can be implemented in the hot, dry climate of the Southwest. In addition, the homes were used as an educational experience for home performance professionals, building trades, remodelers, and the general public. In-field trainings on air-sealing, HVAC upgrades, and insulating were provided to local contractors during the retrofit and BARA documented these retrofits through a series of video presentations, beginning with a site survey and concluding with the finished remodel and test out.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Laboratory Testing of Portable Air Cleaner Products for Energy Efficiency and Clean Air Performance at Various Fan Settings [Slides]

This document contains the results of a product review and laboratory testing experiment of portable air cleaning devices (PACs). Thirty-four commercially available PACs were reviewed, and from those, 7 products were purchased and underwent AHAM AC-7 clean air delivery rate (CADR) testing. The following research questions were explored: 1) What is the relationship between clean air delivery rate (CADR) and energy across a range of products and what is the general decrement in CADR as a result of operating at lower fan speeds? 2) How might the multiple units at lower power compare to fewer, larger units at full power in terms of energy efficiency and total cost? 3) How do the measured CADR, power, and efficiency compare to the manufacturer specs? 4) Are there product attributes that can be identified that might contribute to better CADR/W performance?

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Efficient Computing R&D Roadmap Outline for Automated Vehicles

Automated vehicles (AV) hold great promise for improving safety, as well as reducing congestion and emissions. In order to make automated vehicles commercially viable, a reliable and highperformance vehicle-based computing platform that meets ever-increasing computational demands will be key. Given the state of existing digital computing technology, designers will face significant challenges in meeting the needs of highly automated vehicles without exceeding thermal constraints or consuming a large portion of the energy available on vehicles, thus reducing range between charges or refills. The accompanying increases in energy for AV use will place increased demand on energy production and distribution infrastructure, which also motivates increasing computational energy efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Chapter 22: Compressed Air Evaluation Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

Compressed-air systems are used widely throughout industry for many operations, including pneumatic tools, packaging and automation equipment, conveyors, and other industrial process operations. Compressed-air systems are defined as a group of subsystems composed of air compressors, air treatment equipment, controls, piping, pneumatic tools, pneumatically powered machinery, and process applications using compressed air. A compressed-air system has three primary functional subsystems: supply, distribution, and demand. Air compressors are the primary energy consumers in a compressed-air system and are the primary focus of this protocol. The two compressed-air energy efficiency measures specifically addressed in this protocol are: High-efficiency/variable speed drive (VSD) compressor replacing modulating, load/unload, or constant-speed compressor; and Compressed-air leak survey and repairs. This protocol provides direction on how to reliably verify savings from these two measures using a consistent approach for each.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Catalytic reactive separation system for energy-efficient production of cumene

The present invention relates to an atmospheric pressure, reactive separation column packed with a solid acid zeolite catalyst for producing cumene from the reaction of benzene with propylene. Use of this un-pressurized column, where simultaneous reaction and partial separation occur during cumene production, allow separation of un-reacted, excess benzene from other products as they form. This high-yielding, energy-efficient system allows for one-step processing of cumene, with reduced need for product purification. Reacting propylene and benzene in the presence of beta zeolite catalysts generated a selectivity greater than 85% for catalytic separation reactions at a reaction temperature of 115 degrees C and at ambient pressure. Simultaneously, up to 76% of un-reacted benzene was separated from the product; which could be recycled back to the reactor for re-use.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Energy-efficient multimodal mobility networks in transportation digital twins: Strategies and optimization

The study proposes a comprehensive Transportation Mobility (TransitMo) framework covering conceptual design, model formulation, optimization, simulation, and impact analysis of the transportation mobility system. TransitMo is composed of a transportation digital twin developed in Simulation of Urban MObility (SUMO) and an Intelligent Traffic Management and Control Center (ITMCC) that identifies the best ways to improve the movement of people within urban areas using various modes of transportation. This study encompasses advanced modeling techniques, algorithms, and strategic testing to optimize energy efficiency and mobility in a multimodal shared mobility network. TransitMo’s practical applications are exemplified through a city-scaled simulation network in Chattanooga, TN, employing demographic data to analyze historical traffic patterns and forecast future demands. Central to this methodology are three models: the User Preference Model (UP), the Energy Consumption Model (EC), and the System Optimization Model (SO). These models work in concert to iteratively devise the optimal travel incentives and minimize the total system cost in a real-time manner. In conclusion, test results verified that the proposed adaptive incentive program and optimized bus scheduling can improve network performance by increasing public transit ridership.

42 ENGINEERING↗

Energy-Efficient Systems Eliminate Icing Danger for UAVs

Ames Research Center engineer Leonard Haslim invented an anti-icing t echnology called an electroexpulsive separation system, which uses m echanical force to shatter potentially dangerous ice buildup on an ai rcraft surface. Temecula, California-based Ice Management Systems (no w known as IMS-ESS) licensed the technology from Ames and has discov ered a niche market for the lightweight, energy-efficient technology: unmanned aerial vehicles (UAVs). IMS-ESS systems now prevent damagi ng ice accumulation on military UAVs, allowing the vehicles to carry out crucial missions year round.

Source record↗

Climate benefits and building energy efficiency gains from improved roofing insulation in cold climates

The high thermal resistivity of polyisocyanurate insulation is attributed to its closed cell structure that is filled with low-thermal-conductivity blowing agent vapor. However, existing polyisocyanurate products exhibit a decrease in their thermal-resistance values at lower temperatures due to the condensation of the blowing agent vapor. Because use of insulation with higher thermal resistivity can lead to improved energy efficiency of commercial buildings, which results in lower operational greenhouse gas emissions, there is a clear need to address this reduced performance at lower temperatures through product innovation.

54 ENVIRONMENTAL SCIENCES↗

Improving chiller performance and energy efficiency in hydrogen station operation by tuning the auxiliary cooling

In a hydrogen station that operates with direct fueling through the use of a 700 bar boost compressor, the outlet hydrogen temperature can significantly increase, stressing the chiller system. Here, this paper evaluates improvements that can be made to the auxiliary cooling system integrated with the compressor. Both theoretical modeling and experiments were performed at Cal State LA Hydrogen Research and Fueling Facility. The findings suggest that adjusting the auxiliary closed-loop cooling system from 15 °C to 10 °C reduced the station energy consumption and decreased the demand on the station chiller that needed to provide –20 °C hydrogen at the hose. The overall energy consumption for a single fueling reduced by between 2.86 and 9.43% for the set of experiments conducted. After the temperature of the closed-loop cooling system was reduced by 5 °C, the boost compressor outlet temperature dropped from 46-50 °C–40 °C and consequently at the hose the hydrogen temperature declined by 3 °C. Results were scaled up with a forecast on the number of daily refueling events. With a low number of daily fuelings, the proposed set-up showed a minor influence on the overall station energy consumption. However, the benefits were more pronounced for a connector station with sales at 180 kg/day, where the energy efficiency improved by between 1.4 and 5.5%, and even more so for a higher capacity station at 360 kg/day, where the improvement was between 2.9 and 8%.

08 HYDROGEN↗

Effect of Viscosity of a Deep Eutectic Solvent on CO 2 Capture Performance in an Energy-Efficient Membrane Contactor-Based Process

Greenhouse gas contributions to climate change have driven intense interest in the separation of CO 2 from wet flue gas streams. Deep eutectic solvents (DESs) are an emerging class of highly selective CO 2 absorbents. A prototypical DES, reline, is a mixture of choline chloride and urea. Reline is a thermally stable, nontoxic, and biodegradable solvent with negligible volatility and is inexpensive. We demonstrate a scalable and energy-efficient hollow fiber membrane contactor (HFMC)-based process using a green solvent for CO 2 capture. This process uses reline in HFMC to provide close interfacial interactions and contact between DES and CO 2 . This approach overcomes the disadvantages associated with direct absorption in DES and could potentially be applied to a variety of solvent-based CO 2 capture methods. Commercial, low-cost polymer hollow fiber membranes were evaluated for the capture of CO 2 with reline. From a mixed gas containing N 2 and CO 2 , the DES-based HFMC separated CO 2 with a purity of 97 mol %. The effect of the viscosity of reline on the CO 2 capture performance was investigated by adding water to the reline. The addition of water to reline significantly reduced its viscosity, which led to a permeate flux of 170 mmol/(m 2 ·h) at 35 °C, 4 bar, and 60 wt % water in solvent, which was approximately 8 times higher than that of the pure reline in the membrane contactor system. In situ Fourier transform infrared spectroscopy and nuclear magnetic resonance (NMR) revealed that reline absorbs CO 2 by physical absorption without forming new chemical compounds and that CO 2 separation by reline occurs via the pressure swing mechanism. This research provides fundamental insights about green physical solvent-based separation processes and a pathway toward industrial deployment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Energy Efficient Large-Scale Storage of Liquid Hydrogen

World’s largest LH2storage tanks constructed in mid-1960s at NASA/KSC. These vacuum-perlite insulated tanks, still in service today, are 3,200 m3capacity (ea.). In 2018, construction began on an additional 4,700 m3LH2storage tank at LC-39B•NASA’s new Space Launch System (SLS) heavy lift rocket for Artemis program holds 2,033 m3of LH2in its 8.4-m diameter by 40-m height. Two new energy-efficient technologies are included: glass bubbles insulation system and an Integrated Refrigeration and Storage (IRAS) heat exchanger for passive + active thermal control:•Evacuated glass bubbles insulation system has been shown to reduce LH2boiloff by 46% versus perlite in field demonstrations. Controlled storage via IRAS, when fully implemented, will provide full control of ullage pressure, zero boiloff, and even production of densified LH22CEC-2021

cryogenics↗

Regency Centers Develops Leadership in Energy-Efficient Renovations

Regency Centers (Regency) partnered with the Department of Energy (DOE) to develop and implement solutions to retrofit existing buildings to reduce energy consumption by at least 30% versus requirements set by Standard 90.1-2004 of the American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE), the American National Standards Institute (ANSI), and the Illuminating Engineering Society of North America (IESNA) as part of DOE’s Commercial Building Partnerships (CBP) Program.

EEMs↗

Evaluation of the Energy-Efficiency of an Aerated Slurry-Infiltrated Mesh Building System with Biomass-Based Insulation

Experimental investigations and numerical analyses were conducted on the thermal attributes of a building system made with locally available structural and insulation materials. The structural material, which also offers some insulation qualities, is referred to as aerated slurry-infiltrated mesh. The insulation materials used in this building are based on biomass; the alternatives considered here include ground wood, shredded straw, and cellulose. Thermal conductivity tests were performed on aerated slurries of different bulk densities, and on the biomass-based insulation materials, some of which were prepared with different bulk densities. The competitive merits of the biomass-based indigenous insulation materials were assessed. The correlations between bulk density and thermal conductivity were evaluated and rationalized based on the prevalent mechanisms of heat transfer in different materials. The effects of temperature on the thermal conductivity of different biomass-based indigenous insulation materials were investigated. For wall insulation, a cost analysis was conducted in order to select the optimum insulation level. As a result, the thermal mass of the aerated slurry-infiltrated mesh building system was found to favor its energy-efficiency when compared with a similar wood building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Robust, Scalable Platform for the Electrochemical Conversion of CO 2 to Formate: Identifying Pathways to Higher Energy Efficiencies

This work demonstrated a robust, scalable cell architecture for electroreduction of CO 2 (CO 2 R). An up to 90% faradaic efficiency for the conversion of CO 2 R to formate at 500 mA/cm 2 was realized at a 25 cm2 gas diffusion electrode (GDE) with a carbon-supported SnO 2 electrocatalyst. Furthermore, a 1.27 mm thick catholyte was used between the bipolar membrane and cathode GDE, which could be further reduced to tens of micrometers upon refinement. The deconvolution of the potential drop from each individual component/process guides the pathways to higher energy efficiencies of CO 2 R at this platform. Significant changes in the agglomerate size and aspect ratio on the electrode before and after an 11 h test were revealed by nano-CT, suggesting reduced CO 2 accessibility from electrode degradation. The versatility of this CO 2 R testing platform enables the ability to assess materials, components, and interactions at scales more in line with future devices.

30 DIRECT ENERGY CONVERSION↗

Ageless Aluminum-Cerium-Based Alloys in High-Volume Die Casting for Improved Energy Efficiency

Strong chemical reactions between Al and Ce lead to the formation of intermetallics with exceptional thermal stability. The rapid formation of intermetallics directly from the liquid phase during solidification of Al-Ce alloys leads to an ultrafine microconstituent structure that effectively strengthens as-cast alloys without further microstructural optimization via thermal processing. Die casting is a high-volume manufacturing technology that accounts for greater than 40% of all cast Al products, whereas Ce is highly overproduced as a waste product of other rare earth element (REE) mining. Reducing heat treatments would stimulate significant improvements in manufacturing energy efficiency, exceeding (megatonnes/year) per large-scale heat-treatment line. In this study, multiple compositions were evaluated with wedge mold castings to test the sensitivity of alloys to the variable solidification rate inherent in high-pressure die casting. Once a suitable composition was determined, it was successfully demonstrated at 800 lbs/h in a 600-ton die caster, after which the as-die cast parts performed similarly to ubiquitous A380 in the same geometry without requiring heat treatment. Furthermore, this work demonstrates the compatibility of Al REE alloys with high-volume die-casting applications with minimal heat treatments.

36 MATERIALS SCIENCE↗