Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electronic noise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Controller for the Electronically Scanned Thinned Array Radiometer (ESTAR) instrument

A prototype controller for the ESTAR (electronically scanned thinned array radiometer) instrument has been designed and tested. It manages the operation of the digital data subsystem (DDS) and its communication with the Small Explorer data system (SEDS). Among the data processing tasks that it coordinates are FEM data acquisition, noise removal, phase alignment and correlation. Its control functions include instrument calibration and testing of two critical subsystems, the output data formatter and Walsh function generator. It is implemented in a Xilinx XC3064PC84-100 field programmable gate array (FPGA) and has a maximum clocking frequency of 10 MHz.

Zomberg, Brian G.↗

Detection of Chamber Conditioning by CF4 in the GEC Cell

During oxide etch processes, buildup of fluorocarbon residues on reactor sidewalks can cause to drift and will necessitate time for conditioning and cleaning of the reactor. Various measurements in CF4 and Ar plasmas are made in an attempt to identify a metric able to indicate the chamber condition. Mass spectrometry and a Langmuir probe shows that the buildup of fluorocarbon films on the reactor surface causes a decrease in plasma floating potential, plasma potential, and ion energy in argon plasmas. This change in floating potential is also observed in CF4 plasma operation, and occurs primarily during the first hour and a half of plasma operation. A slight rise in electron density is also observed in the argon plasmas. Because the change is seen in an argon plasma, it is indicative of altered physical, not chemical, plasma-surface interactions. Specifically, the insulating films deposited on metal surfaces alter the electromagnetic fields seen by the plasma, affecting various parameters including the floating potential and electron density. An impedance probe placed on the inductive coil shows a slight reduction in plasma impedance due to this rising electron density. The optical emission of several species, including CF, C2, atomic Si and atomic C, is also monitored for changes in density resulting from the buildup of film on the chamber wall. Changes in the optical emission spectrum are comparable to the noise levels in their measurement.

Cruden, Brett A.↗

Demonstration of the First 4H-SiC EUV Detector with Large Detection Area

Ultraviolet (UV) and Extreme Ultraviolet (EUV) detectors are very attractive in astronomy, photolithography and biochemical applications. For EUV applications, most of the semiconductor detectors based on PN or PIN structures suffer from the very short penetration depth. Most of the carries are absorbed at the surface and recombined there due to the high surface recombination before reach the depletion region, resulting very low quantum efficiency. On the other hand, for Schottky structures, the active region starts from the surface and carriers generated from the surface can be efficiently collected. 4H-Sic has a bandgap of 3.26eV and is immune to visible light background noise. Also, 4H-Sic detectors usually have very good radiation hardness and very low noise, which is very important for space applications where the signal is very weak. The E W photodiodes presented in this paper are based on Schottky structures. Platinum (Pt) and Nickel (Ni) are selected as the Schottky contact metals, which have the highest electron work functions (5.65eV and 5.15eV, respectively) among all the known metals on 4H-Sic.

Xin, Xiaobin↗

A (13)C NMR analysis of the effects of electron radiation on graphite/polyetherimide composites

Initial investigations have been made into the use of high resolution nuclear magnetic resonance (NMR) for the characterization of radiation effects in graphite and Kevlar fibers, polymers, and the fiber/matrix interface in graphite/polyetherimide composites. Sample preparation techniques were refined. Essential equipment has been procured. A new NMR probe was constructed to increase the proton signal-to-noise ratio. Problem areas have been identified and plans developed to resolve them.

Ferguson, Milton W.↗

Quantum-Based Molecular Dynamics Simulations Using Tensor Cores

Tensor cores, along with tensor processing units, represent a new form of hardware acceleration specifically designed for deep neural network calculations in artificial intelligence applications. Tensor cores provide extraordinary computational speed and energy efficiency but with the caveat that they were designed for tensor contractions (matrix–matrix multiplications) using only low-precision floating-point operations. Despite this perceived limitation, we demonstrate how tensor cores can be applied with high efficiency to the challenging and numerically sensitive problem of quantum-based Born–Oppenheimer molecular dynamics, which requires highly accurate electronic structure optimizations and conservative force evaluations. The interatomic forces are calculated on-the-fly from an electronic structure that is obtained from a generalized deep neural network, where the computational structure naturally takes advantage of the exceptional processing power of the tensor cores and allows for high performance in excess of 100 Tflops on a single Nvidia A100 GPU. Stable molecular dynamics trajectories are generated using the framework of extended Lagrangian Born–Oppenheimer molecular dynamics, which combines computational efficiency with long-term stability, even when using approximate charge relaxations and force evaluations that are limited in accuracy by the numerically noisy conditions caused by the low-precision tensor core floating-point operations. A canonical ensemble simulation scheme is also presented, where the additional numerical noise in the calculated forces is absorbed into a Langevin-like dynamics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluating a quantum-classical quantum Monte Carlo algorithm with Matchgate shadows

Solving the electronic structure problem of molecules and solids to high accuracy is a major challenge in quantum chemistry and condensed matter physics. The rapid emergence and development of quantum computers offer a promising route to systematically tackle this problem. Recent work by [Huggins et al ., Nature (London) 603 , 416 (2022)] proposed a hybrid quantum-classical quantum Monte Carlo (QC-QMC) algorithm using Clifford shadows to determine the ground state of a Fermionic Hamiltonian. This approach displayed inherent noise resilience and the potential for improved accuracy compared to its purely classical counterpart. Nevertheless, the use of Clifford shadows introduces an exponentially scaling postprocessing cost. In this work, we investigate an improved QC-QMC scheme utilizing the recently developed Matchgate shadows technique [Commun. Math. Phys. 404 , 629 (2023)], which removes the aforementioned exponential bottleneck. We observe from experiments on quantum hardware that the use of Matchgate shadows in QC-QMC is inherently noise robust. We show that this noise resilience has a more subtle origin than in the case of Clifford shadows. Nevertheless, we find that classical postprocessing, while asymptotically efficient, requires hours of runtime on thousands of classical CPUs for even the smallest chemical systems, presenting a major challenge to the scalability of the algorithm.

Monte Carlo methods↗

Statistical analysis of non-Maxwellian electron distribution functions measured with angularly resolved Thomson scattering

Angularly resolved Thomson scattering is a novel extension of Thomson scattering, enabling the measurement of the electron velocity distribution function over many orders of magnitude. Here, details of the theoretical basis of the technique and the instrument designed for this measurement are described. Angularly resolved Thomson-scattering data from several experiments are shown with descriptions of the corresponding distribution functions. A reduced model describing the distribution function is given and used to perform a Monte Carlo analysis of the uncertainty in the measurements. The electron density and temperature were determined to a precision of 12% and 21%, respectively, on average, while all other parameters defining the distribution function were generally determined to better than 20%. It was found that these uncertainties were primarily due to limited signal to noise and instrumental effects. Furthermore, measurements with this level of precision were sufficient to distinguish between Maxwellian and non-Maxwellian distribution functions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Radiation Testing for High-Resolution Radiation-Hardened Camera System (Final CRADA Report)

The nuclear energy industry needs higher-image quality and higher rad-hard vision systems for refueling and inspection operations that are required every 12-18 months for all operating commercial reactors. During refueling operations, the serial numbers of fuel assemblies need to be visually verified in a challenging high radiation environment with dose rates on the order of 1kGy/hr. at the top of the core (approximately 10 days after shutdown). Vega Wave Systems has developed and built a radiation hard vision system that: 1. has high radiation hardness, 2. demonstrated best in the industry image quality, 3. has small size and weight, and 4. does not suffer from radiation-induced noise. ANL-1060 (02/13/2023) The proprietary Enduray vision system from Vega Wave Systems, Inc. is designed to withstand more than 400x the radiation level of the Vidicon-based systems, currently the highest radiation tolerant system in use today. The Van De Graaff (VDG) electron accelerator at Argonne National Laboratory is ideally suited for testing of Enduray vision system. VDG provides a broad band (up to 3 MeV) x-ray source that reasonably approximates the energy and spectrum of the gamma radiation expected at the top of a nuclear core 10 days after shutdown (~1kGy/hr.), is easily controlled for variable tests, and will not activate the parts under radiation for ease of timely and close inspection and characterization of the system in case of operational issues.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Toward an image compression algorithm for the high-resolution electronic still camera

Taking pictures with a camera that uses a digital recording medium instead of film has the advantage of recording and transmitting images without the use of a darkroom or a courier. However, high-resolution images contain an enormous amount of information and strain data-storage systems. Image compression will allow multiple images to be stored in the High-Resolution Electronic Still Camera. The camera is under development at Johnson Space Center. Fidelity of the reproduced image and compression speed are of tantamount importance. Lossless compression algorithms are fast and faithfully reproduce the image, but their compression ratios will be unacceptably low due to noise in the front end of the camera. Future efforts will include exploring methods that will reduce the noise in the image and increase the compression ratio.

Nerheim, Rosalee↗

Cool and Quiet: Partnering to Enhance the Aerodynamic and Acoustic Performance of Installed Electronics Cooling Fans: A White Paper

Breathtaking images of distant planets. Spacewalks to repair a telescope in orbit. Footprints on the moon. The awesome is made possible by the mundane. Every achievement in space exploration has relied on solid, methodical advances in engineering. Space exploration fuels economic development like no other endeavor can. But which advances will make their way into our homes and businesses? And how long will it take? Answers to these questions are dependent upon industrial involvement in government sponsored research initiatives, market demands, and timing. Recognizing an opportunity is half the battle. This proposal describes the framework for a collaborative research program aimed at improving the aerodynamic and acoustic performance of electronics cooling fans. At its best, the program would involve NASA and academic researchers, as well as corporate researchers representing the Information Technology (IT) and fan manufacturing industries. The momentum of space exploration, the expertise resultant from the nation's substantial investment in turbofan noise reduction research, and the competitiveness of the IT industry are intended to be catalysts of innovation.

Koch, L. Danielle↗

Coronal Mass Ejections and Solar Radio Emissions

Coronal mass ejections (CMEs) have important connections to various types of radio emissions from the Sun. The persistent noise storm radiation (type I storm at metric wavelengths, type III storms at longer wavelengths) can be clearly interrupted by the occurrence of a CME in the active region that produces the storm. Sometimes the noise storm completely disappears and other times, it reappears in the active region. Long-lasting type III bursts are associated with CME eruption, thought to be due to the reconnection process taking place beneath the erupting CME. Type II bursts are indicative of electron acceleration in the CME-driven shocks and hence considered to be the direct response of the CME propagation in the corona and interplanetary medium. Finally type IV bursts indicate large-scale post-eruption arcades containing trapped electrons that produce radio emission. This paper summarizes some key results that connect CMEs to various types of radio emission and what we can learn about particle acceleration in the corona) and interplanetary medium. Particular emphasis will be placed on type If bursts because of their connection to interplanetary shocks detected in situ.

Gopalswamy, Nat↗

Wireless Inductive Power Device Suppresses Blade Vibrations

Vibration in turbomachinery can cause blade failures and leads to the use of heavier, thicker blades that result in lower aerodynamic efficiency and increased noise. Metal and/or composite fatigue in the blades of jet engines has resulted in blade destruction and loss of lives. Techniques for suppressing low-frequency blade vibration, such as gtuned circuit resistive dissipation of vibratory energy, h or simply "passive damping," can require electronics incorporating coils of unwieldy dimensions and adding unwanted weight to the rotor. Other approaches, using vibration-dampening devices or damping material, could add undesirable weight to the blades or hub, making them less efficient. A wireless inductive power device (WIPD) was designed, fabricated, and developed for use in the NASA Glenn's "Dynamic Spin Rig" (DSR) facility. The DSR is used to simulate the functionality of turbomachinery. The relatively small and lightweight device [10 lb (approx.=4.5 kg)] replaces the existing venerable and bulky slip-ring. The goal is the eventual integration of this technology into actual turbomachinery such as jet engines or electric power generators, wherein the device will facilitate the suppression of potentially destructive vibrations in fan blades. This technology obviates slip rings, which require cooling and can prove unreliable or be problematic over time. The WIPD consists of two parts: a remote element, which is positioned on the rotor and provides up to 100 W of electrical power to thin, lightweight piezoelectric patches strategically placed on/in fan blades; and a stationary base unit that wirelessly communicates with the remote unit. The base unit supplies inductive power, and also acts as an input and output corridor for wireless measurement, and active control command to the remote unit. Efficient engine operation necessitates minimal disturbance to the gas flow across the turbine blades in any effort to moderate blade vibration. This innovation makes it possible to moderate vibration on or in turbomachinery blades by providing 100 W of wireless electrical power and actuation control to thin, lightweight vibration-suppressing piezoelectric patches (eight actuation and eight sensor patches in this prototype, for a total of 16 channels) positioned strategically on the surface of, or within, titanium fan blades, or embedded in composite fan blades. This approach moves significantly closer to the ultimate integration of "active" vibration suppression technology into jet engines and other turbomachinery devices such as turbine electrical generators used in the power industry. The novel feature of this device is in its utilization of wireless technology to simultaneously sense and actively control vibration in rotating or stationary turbomachinery blades using piezoelectric patches. In the past, wireless technology was used solely for sensing and diagnostics. This technology, however, will accomplish much more, in terms of simultaneously sensing, suppressing blade vibration, and making it possible for detailed study of vibration impact in turbomachinery blades.

Morrison, Carlos R.↗

Online and Offline Data Quality Monitoring for the Mu2e Calorimeter

This thesis presents the design, implementation, and validation of a calorimeter Data Quality Monitoring (DQM) toolchain for the Mu2e experiment at Fermilab. Mu2e searches for charged lepton flavor violation via coherent muon-to-electron conversion in the field of an aluminum nucleus, $\mu^- Al \rightarrow e^-Al$, a process whose observation would constitute clear evidence of physics beyond the Standard Model. Achieving target sensitivity requires stringent control of detector performance and data integrity during acquisition, as subtle issues in readout configuration, data formatting, or electronics behavior can compromise reconstruction and bias downstream analyzes. To address these challenges, this work develops a multi-layer DQM approach spanning both raw data validation and reconstructed digi-level diagnostics. At the low level, a fragment analysis component performs word- and bit-field decoding of calorimeter readout blocks, enabling sanity checks of the expected structure and producing detailed error and integrity statistics useful for commissioning and troubleshooting. At the digi level, the CaloDigiDQM analyzer is implemented within the art framework and transforms each CaloDigiCollection into a structured hierarchy of ROOT histograms designed for fast drill-down diagnostics. The module generates coherent monitoring views at global, disk, board, and channel granularity, including occupancy, waveform-derived features (baseline, RMS, peak amplitude and position), and left-right sensor consistency metrics. Detector-aware channel-to-electronics mapping is performed through the conditions system (CaloDAQMap), ensuring that diagnostics remain aligned with hardware identifiers used in operations. For end-to-end testing without reliance on live DAQ data, a synthetic CaloDigi producer is developed to generate realistic waveforms with controlled noise and pulse shapes. The resulting system supports both offline ROOT-file production and online operation, including optional histogram streaming through otsdaq via ots::HistoSender. This toolchain provides a practical and scalable foundation for calorimeter commissioning and stable data collection, enabling early detection of anomalies and reducing operational risk for Mu2e.

Vakulenko, Mark [Drew U.] (ORCID:0009000276197818)↗

Enhancing hyperspectral EELS analysis of complex plasmonic nanostructures with pan-sharpening

Nanoscale hyperspectral techniques—such as electron energy loss spectroscopy (EELS)—are critical to understand the optical response in plasmonic nanostructures, but as systems become increasingly complex, the required sampling density and acquisition times become prohibitive for instrumental and specimen stability. As a result, there has been a recent push for new experimental methodologies that can provide comprehensive information about a complex system, while significantly reducing the duration of the experiment. In this work, we present a pan-sharpening approach to hyperspectral EELS analysis, where we acquire two datasets from the same region (one with high spatial resolution and one with high spectral fidelity) and combine them to achieve a single dataset with the beneficial properties of both. This work outlines a straightforward, reproducible pathway to reduced experiment times and higher signal-to-noise ratios, while retaining the relevant physical parameters of the plasmonic response, and is generally applicable to a wide range of spectroscopy modalities.

36 MATERIALS SCIENCE↗

Nuclear spin assisted magnetic field angle sensing

Abstract Quantum sensing exploits the strong sensitivity of quantum systems to measure small external signals. The nitrogen-vacancy (NV) center in diamond is one of the most promising platforms for real-world quantum sensing applications, predominantly used as a magnetometer. However, its magnetic field sensitivity vanishes when a bias magnetic field acts perpendicular to the NV axis. Here, we introduce a different sensing strategy assisted by the nitrogen nuclear spin that uses the entanglement between the electron and nuclear spins to restore the magnetic field sensitivity. This, in turn, allows us to detect small changes in the magnetic field angle relative to the NV axis. Furthermore, based on the same underlying principle, we show that the NV coupling strength to magnetic noise, and hence its coherence time, exhibits a strong asymmetric angle dependence. This allows us to uncover the directional properties of the local magnetic environment and to realize maximal decoupling from anisotropic noise.

Physics↗

Ideal Integrating Bolometer

We describe a new 'ideal integrator' bolometer as a prototype for a new generation of sensitive, flexible far-IR detectors suitable for use in large arrays. The combination of a non-dissipative sensor coupled with a fast heat switch provides breakthrough capabilities in both sensitivity and operation. The bolometer temperature varies linearly with the integrated infrared power incident on the detector, and may be sampled intermittently without loss of information between samples. The sample speed and consequent dynamic range depend only on the heat switch reset cycle and can be selected in software. Between samples, the device acts as an ideal integrator with noise significantly lower than resistive bolometers. Since there is no loss of information between samples, the device is well-suited for large arrays. A single SQUID readout could process an entire column of detectors, greatly reducing the complexity, power requirements, and cost of readout electronics for large pixel arrays.

Kogut, Alan↗

Ideal Integrating Bolometer

We describe a new "ideal integrator" bolometer as a prototype for a new generation of sensitive, flexible far-IR detectors suitable for use in large arrays. The combination of a non-dissipative sensor coupled with a fast heat switch provides breakthrough capabilities in both sensitivity and operation. The bolometer temperature varies linearly with the integrated infrared power incident on the detector, and may be sampled intermittently without loss of information between samples. The sample speed and consequent dynamic range depend only on the heat switch reset cycle and can be selected in software. Between samples, the device acts as an ideal integrator with noise significantly lower than resistive bolometers. Since there is no loss of information between samples, the device is well-suited for large arrays. A single SQUID readout could process an entire column of detectors, greatly reducing the complexity, power requirements, and cost of readout electronics for large pixel arrays.

Kogut, A.↗

Delta-Doped CCDs as Detector Arrays in Mass Spectrometers

In a conventional mass spectrometer, charged particles (ions) are dispersed through a magnetic sector onto an MCP at an output (focal) plane. In the MCP, the impinging charged particles excite electron cascades that afford signal gain. Electrons leaving the MCP can be read out by any of a variety of means; most commonly, they are post-accelerated onto a solid-state detector array, wherein the electron pulses are converted to photons, which, in turn, are converted to measurable electric-current pulses by photodetectors. Each step in the conversion from the impinging charged particles to the output 26 NASA Tech Briefs, February 2007 current pulses reduces spatial resolution and increases noise, thereby reducing the overall sensitivity and performance of the mass spectrometer. Hence, it would be preferable to make a direct measurement of the spatial distribution of charged particles impinging on the focal plane. The utility of delta-doped CCDs as detectors of charged particles was reported in two articles in NASA Tech Briefs, Vol. 22, No. 7 (July 1998): "Delta-Doped CCDs as Low-Energy-Particle Detectors" (NPO-20178) on page 48 and "Delta- Doped CCDs for Measuring Energies of Positive Ions" (NPO-20253) on page 50. In the present developmental miniature mass spectrometers, the above mentioned miniaturization and performance advantages contributed by the use of delta-doped CCDs are combined with the advantages afforded by the Mattauch-Herzog design. The Mattauch- Herzog design is a double-focusing spectrometer design involving an electric and a magnetic sector, where the ions of different masses are spatially separated along the focal plane of magnetic sector. A delta-doped CCD at the focal plane measures the signals of all the charged-particle species simultaneously at high sensitivity and high resolution, thereby nearly instantaneously providing a complete, high-quality mass spectrum. The simultaneous nature of the measurement of ions stands in contrast to that of a scanning mass spectrometer, in which abundances of different masses are measured at successive times.

Nikzad, Shouleh↗