Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “distribution system monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Ultrasonic Guided-Wave-Scan System Used to Characterize C-Enhanced Silicon Carbide Composite During Creep- Rupture Tests

Ceramic matrix composites (CMCs) are being developed for advanced aerospace propulsion applications in order to save weight, improve reuse capability, and increase performance. However, mechanical and environmental loads applied to CMCs can cause degradation in the form of discrete flaws and distributed microdamage that can play a significant role in reducing desirable physical properties. Categories of microdamage include fiber/matrix debonding (interface failure), matrix microcracking, fiber fracture and buckling, oxidation, and second-phase formation. Distributed microdamage in CMCs has proven difficult to characterize nondestructively because of the complex microstructure and macrostructure of these materials, and a recent study regarding the durability of a ceramic matrix composite discussed the requirement for improved nondestructive evaluation (NDE) methods for monitoring degradation in these materials.

Roth, Don J.↗

OpenSAMPL: An Open Source Library for Timing and Synchronization Measurements and Analytics

Today's power grid operators are implementing timing and synchronization solutions that provide resilience to Global Navigation Satellite System (GNSS) vulnerabilities. These vendor-specific solutions often come with additional software applications that are designed to monitor that vendor's synchronization performance data. However, resilient timing architectures often resulting in multi-vendor solutions, including approaches that blend terrestrial clocks with space-based subscription services. In such an environment, collecting, analyzing, and visualizing data from a variety of sources within a single platform was heretofore not possible. To address this need, the US Department of Energy's Center for Alternative Synchronization and Timing (CAST) developed OpenSAMPL, the Open Synchronized Analytics and Monitoring Platform, an open-source Python framework for processing, loading, and observing clock measurement data from distributed devices. OpenSAMPL enables the ingestion of diverse clock-probe sources into a scalable time-series database and applies robust analytics. OpenSAMPL currently supports two vendor data pipelines, and will be extended to more in the near future, enabling seamless monitoring of a variety of timing and synchronization devices in a common environment.

Grant, Josh [ORNL] (ORCID:0000000163475060)↗

Recent advances in radar remote sensing of forest

On a global scale, forests represent most of the terrestrial standing biomass (80 to 90 percent). Thus, natural and anthropogenic change in forest covers can have major impacts not only on local ecosystems but also on global hydrologic, climatic, and biogeochemical cycles that involve exchange of energy, water, carbon, and other elements between the earth and atmosphere. Quantitative information on the state and dynamics of forest ecosystems and their interactions with the global cycles appear necessary to understand how the earth works as a natural system. The information required includes the lateral and vertical distribution of forest cover, the estimates of standing biomass (woody and foliar volume), the phenological and environmental variations and disturbances (clearcutting, fires, flood), and the longer term variations following deforestation (regeneration, successional stages). To this end, seasonal, annual, and decadal information is necessary in order to separate the long term effects in the global ecosystem from short term seasonal and interannual variations. Optical remote sensing has been used until now to study the forest cover at local, regional, and global scales. Radar remote sensing, which provides recent SAR data from space on a regular basis, represents an unique means of consistently monitoring different time scales, at all latitudes and in any atmospheric conditions. Also, SAR data have shown the potential to detect several forest parameters that cannot be inferred from optical data. The differences--and complementarity--lie in the penetration capabilities of SAR data and their sensitivity to dielectric and geometric properties of the canopy volume, whereas optical data are sensitive to the chemical composition of the external foliar layer of the vegetation canopy.

Letoan, Thuy↗

Nondestructive Evaluation of Adhesively Bonded Joints by Acousto-Ultrasonic Technique and Acoustic Emission

Reliable applications of adhesively bonded joints require an effective nondestructive evaluation technique for their bond strength prediction. To properly evaluate factors affecting bond strength, effects of defects such as voids and disbonds on stress distribution in the overlap region must be understood. At the same time, in order to use acousto-ultrasonic (AU) technique to evaluate bond quality, the effect of these defects on dynamic response of single lap joints must be clear. The stress distribution in a single lap joint with and without defects (void or disbond) is analyzed. A bar-Theta parameter which contains adherend and adhesive thickness and properties is introduced. It is shown for bonded joints with bar-Theta greater than 10, that a symmetric void or disbond in the middle of overlap up to the 70 percent of overlap length has negligible effect on bond strength. In contrast frequency response analyses by a finite element technique showed that the dynamic response is affected significantly by the presence of voids or disbonds. These results have direct implication in the interpretations of AU results. Through transmission attenuation and a number of AU parameters for various specimens with and without defects are evaluated. It is found that although void and disbond have similar effects on bond strength (stress distribution), they have completely different effects on wave propagation characteristics. For steel-adhesive-steel specimens with voids, the attenuation changes are related to the bond strength. However, the attenuation changes for specimens with disbond are fairly constant over a disbond range. In order to incorporate the location of defects in AU parameters, a weighting function is introduced. Using an immersion system with focused transducers, a number of AU parameters are evaluated. It is found that by incorporating weighting functions in these parameters better sensitivities (AU parameters vs. bond strength) are achieved. Acoustic emission (AE) activities of steel-adhesive-steel specimens with bar-Theta equal to 3.4 are monitored. Two different formats of energy vs. time have resulted, each corresponding to the perfect specimens or the specimens with void or disbond. The relative acoustic energy and the number of events at failure are found to be a means for predicting the bond strength.

Nayeb-Hashemi, Hamid↗

Initial Investigation of the Angular Dependence of the NOAA-20 VIIRS Solar Diffuser BRDF Change Factor

The NOAA-20 (formerly the Joint Polar Satellite System-1) satellite was launched on November 18, 2017. One of the five scientific instruments aboard the NOAA-20 satellite (N20) is the Visible Infrared Imaging Radiometer Suite (VIIRS). The VIIRS scans the earth surface in 22 spectral bands, of which 14 are denoted as the reflective solar bands (RSBs) with design band central wavelengths from 412 to 2250 nm. The VIIRS regularly performs on-orbit radiometric calibration of its RSBs, primarily through observations of an onboard sunlit solar diffuser (SD). The on-orbit change of the SD bidirectional reflectance distribution function (BRDF) value, denoted as the H-factor, is determined by an onboard solar diffuser stability monitor (SDSM). We have shown that the H-factor for the SD on the VIIRS instrument on the Suomi National Polar-orbiting Partnership (SNPP) satellite is both incident and outgoing sunlight direction dependent. This angular dependence profoundly affects the on-orbit radiometric calibration process and results. Here, we give preliminary results for the angular dependence for the N20 VIIRS SD H-factor, and compare the dependence with that for the SNPP VIIRS.

radiometric calibration↗

Mid Infra-Red Laser Sensor for Continuous Sulfur Trioxide Monitoring to Improve Coal-Fired Power Plant Performance during Flexible Operations

During the course of this project, we performed exhaustive research and development of SO3/H2SO4 sensing technology for coal-fired power plant applications (Figure 1). The development culminated in a successful field campaign of a prototype continuous real-time H2SO4 monitor at a coal-fired power plant (TRL 6) accomplishing the primary goal of the project. The developed sensors utilize tunable laser absorption spectroscopy (TLAS) operating in the mid-infrared (Mid-IR) wavelength region, which is the so-called “molecular fingerprint” region. Systems operating in the Mid-IR have orders of magnitude more sensitivity than systems operating at shorter wavelengths, such as near-infrared (NIR). However, NIR systems are more widespread due to more mature supporting technology (e.g., fiber optics, optical components, etc.). In this project, we not only produced a specific Mid-IR sensor, we also advanced Mid-IR sensor technology in general through the development and demonstration of such supporting technology. In this project, we also developed proprietary broad tuning lasers enabling the ability to effectively measure SO3, H2SO4, H2O, and SO2. Different molecular species have unique spectral signatures that can be probed with lasers operating at different wavelengths. Standard TLAS uses relatively narrow wavelength tuning distributed feedback (DFB) lasers, which can typically only target a single species with narrow features, and are not appropriate for species with broad features, such as SO3 or H2SO4. In contrast, by developing unique, broad-tuning laser technology, we were able to measure these species, as well as SO2 and H2O simultaneously. Furthermore, to enable real-time analysis at a power plant, we modified a commercially available heated gas cell to operate in the Mid-IR wavelength range and fiber coupled the lasers to enable remote delivery of the beams. To generate reference data (library spectra), our collaborators at the University of California Irvine (UCI) developed a catalytic SO3 generation facility. It is worth mentioning that representative H2SO4 and SO3 Mid-IR spectra are not a part of any publicly available database and the data generated under this project is a valuable resource in and of itself. In addition, based on the UCI study we determined that detection of SO3 is complicated by the very strong SO2 absorption. For that reason, we concentrated on H2SO4 detection. Since SO3 and H2SO4 exist in a flue gas in a state of equilibrium, which depends on temperature and humidity, by measuring water concentration and controlling the temperature of the gas cell, we developed an approach to determine SO3 concentration from the H2SO4 measurement. During the development phase of the project, we performed three testing campaigns at our collaborator’s FERCo flue gas facility with conditions representative of the coal-fired power plant (~ 40ppm SO3, 1700ppm to 2800 ppm SO2, 10% water) with the exception of particulate matter. After three test campaigns at FERCo we performed field testing at Harrison Power Station. The final system was mounted on a duct and measured H2SO4, SO2 and water. The tests were highly successful with a demonstrated real-time H2SO4 precision of 1 ppm with a 1 second update. Our collaborators at EPRI conducted an industry survey and determined that there is a very high interest for the SO3/H2SO4 monitoring in the power generation industry as well as in heavy industries in general. Furthermore, work performed by OptoKnowledge beyond the scope of this project under a synergistic DOE SBIR determined another approach to SO3 detection. We applied for Phase II on this SBIR for development a of versatile SO3/H2SO4 sensor but were not selected. We are currently looking for another opportunity to leverage all the technological advancements produced by this project including but not limited to the flue gas facility at UCI, the hardware and software developed, and relationships with FERCo, EPRI CEMTEK, and Harrison Station.

01 COAL, LIGNITE, AND PEAT↗

Sandia National Laboratories Annual Site Environmental Report, 2019: New Mexico

Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the United States Department of Energy (DOE) National Nuclear Security Administration. The National Nuclear Security Administration’s Sandia Field Office administers the contract and oversees contractor operations at Sandia National Laboratories, New Mexico. Activities at the site support research and development programs with a wide variety of national security missions, resulting in technologies for nonproliferation, homeland security, energy and infrastructure, and defense systems and assessments. DOE and its management and operating contractor are committed to safeguarding the environment, assessing sustainability practices, and ensuring the validity and accuracy of the monitoring data presented in this Annual Site Environmental Report. This report summarizes the environmental protection and monitoring programs in place at Sandia National Laboratories, New Mexico, during calendar year 2019. Environmental topics include air quality, ecology, environmental restoration, oil storage, site sustainability, terrestrial surveillance, waste management, water quality, and implementation of the National Environmental Policy Act. This report is prepared in accordance with and as required by DOE O 231.1B, Admin Change 1, Environment, Safety, and Health Reporting, and has been approved for public distribution.

54 ENVIRONMENTAL SCIENCES↗

Partitioning of Radionuclides in Various Streams of the Mo-99 Purification Process

The Universal Neutron Irradiator (UNI) was designed to irradiate a small volume of uranium solution and to achieve high fission power without creating a large radionuclide (RN) inventory. The UNI system is equipped with a fully enclosed off-gas system with online hydrogen gas monitoring to prevent the production of an explosive atmosphere, as well as storage cylinders for capturing fission gases. It also includes a catalytic recombiner in the target capsule (to immediately recombine radiolytic hydrogen and oxygen gas in the system) and access ports for sampling the target solution and capsule headspace. In UNI Phase I experiments, 50 mL of uranyl sulfate solution was irradiated at 0.3–0.5 W/mL fission power using a tantalum target assembly to produce photoneutrons via irradiation with an electron beam. The purposes of the Phase I experiments were to test the efficacy of adding 200 ppm Fe 2+ to the target solution to prevent uranyl peroxide precipitation under representative irradiation conditions, and to monitor iodine speciation in the irradiated uranyl sulfate solution. The focus of the UNI Phase II experiments was to use an irradiated uranyl sulfate solution containing a mixture of fission products and monitor their distribution in various streams during the primary recovery column (titania-based column) that separates Mo-99 from uranium. Irradiations were designed to create sufficient activity for tracking their distribution in various processing streams using a combination of gamma counting and inductively coupled plasma mass spectrometry (ICP-MS) analyses. Obtained data will be used to better understand the composition of waste streams, accumulation of RN on the titania column, and identify what RNs accumulate in the uranyl sulfate solution. Furthermore, this knowledge will allow us to determine waste classifications for various streams produced during the Mo-99 purification process and develop an appropriate waste clean-up strategy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The HEAO-B Monitor Proportional Counter Instrument

The Monitor Proportional Counter Instrument for the HEAO-B X-ray Telescope satellite is designed to observe celestial X-ray sources in the range of 1 to 20 keV with intensities exceeding .0002 Crab. It provides both spectral and temporal data, to complement the data from the other HEAO-B instruments, to compare with observations from previous flights, as well as to allow detailed study of time variant X-ray phenomena. The basic detector is a large area proportional counter system, consisting of two counters, high voltage power supplies and preamplifiers, mounted behind a collimator with a 2/3 degree square field of view. The signal processing, power distribution and control electronics are contained in a separate unit, which includes circuitry to perform pulse height analysis, background rejection, time interval measurement, redundancy switching and control, housekeeping and telemetry interfacing.

Gaillardetz, R.↗

Variation of the urban NO2 concentration during a ground inversion situation

In February 1985 the NO2 concentration over Goeteborg, a major Swedish city, was monitored during two inversion situations. The differential absorption technique was employed and the results show the build-up of the concentration. In this experiment the laser beam was scanned horizontally over Goeteborg. The results were presented as maps over the NO2 concentration distribution. For security reasons the beam was not parallel to the ground, which gives a height gradient in some measurements. During the measurement period the NO2 concentration variation build-up from the morning to the afternoon was monitored. Great concentration variations were seen. Later the mixing below the inversion layer, resulting in a more uniform, high concentration was seen. The breakdown of the inversion when stronger winds start was also seen. Comparisons with a traditional point-measuring chemiluminiscence instrument and an optical method DOAS (Differential Optical Absorption Spectroscopy), were made. The results are discussed. Strong spatial concentration variations are shown by the lidar measurements. For a point-measuring system, the instrument must be very carefully placed since its location will strongly influence the values it gives.

Sunesson, A.↗

A Novel Technique for Performing Space Based Radiation Dosimetry Using DNA-Results from GRaDEx-I and the Design of GRaDEx-II

Because of the large amounts of cosmic radiation in the space environment relative to that on earth, the effects of radiation on the physiology of astronauts is of major concern. Doses of radiation which can cause acute or chronic biological effects are to be avoided, therefore determination of the amount of radiation exposure encountered during space flight and assessment of its impact on biological systems is critical. Quantifying the radiation dosage and damage to biological systems, especially to humans during repetitive high altitude flight and during long duration space flight is important for several reasons. Radiation can cause altered biosynthesis and long term genotoxicity resulting in cancer and birth defects etc. Radiation damage to biological systems depends in a complex way on incident radiation species and their energy spectra. Typically non-biological, i.e. film or electronic monitoring systems with narrow energy band sensitivity are used to perform dosimetry and then results are extrapolated to biological models. For this reason it may be desirable to perform radiation dosimetry by using biological molecules e.g. DNA or RNA strands as passive sensors. A lightweight genotoxicology experiment was constructed to determine the degree to which in vitro naked DNA extracted from tissues of a variety of vertebrate organisms is damaged by exposure to radiation in a space environment. The DNA is assayed by means of agarose gel electrophoresis to determine damage such as strand breakage caused by high momentum particles and photons, and base oxidation caused by free radicals. The length distribution of DNA fragments is directly correlated with the radiation dose. It is hoped that a low mass, low cost, passive biological system to determine dose response relationship (increase in strand breaks with increase in exposure) can be developed to perform radiation dosimetry in support of long duration space flight, and to predict negative effects on biological systems (e.g. astronauts and greenhouses) in space. The payload was flown in a 2.5 cubic foot Get Away Special (GAS) container through NASA's GAS program. It was subjected to the environment of the space shuttle cargo bay for the duration of the STS-91 mission (9 days). Results of the genotoxicology and radiation dosimetry experiment (GRaDEx-1) as well as the design of an improved follow on payload are presented.

Ritter, Joe↗

Diagnosability-Based Sensor Placement through Structural Model Decomposition

Systems health management, and in particular fault diagnosis, is important for ensuring safe, correct, and efficient operation of complex engineering systems. The performance of an online health monitoring system depends critically on the available sensors of the system. However, the set of selected sensors is subject to many constraints, such as cost and weight, and hence, these sensors must be selected judiciously. This paper presents an offline design-time sensor placement approach for complex systems. Our diagnosis method is built upon the analysis of model-based residuals, which are computed using structural model decomposition. Sensor placement in this framework manifests as a residual selection problem, and we aim to find the set of residuals that achieves single-fault diagnosability of the system, uses the minimum number of sensors, and corresponds to the best model decomposition for the best distribution of the diagnosis system. We present a set of algorithms for solving this problem and compare their performance in terms of computational complexity and optimality of solutions. We demonstrate the approach using a benchmark multi-tank system.

Daigle, Matthew↗

Gaps in global wildlife trade monitoring leave amphibians vulnerable

As the biodiversity crisis continues, we must redouble efforts to understand and curb pressures pushing species closer to extinction. One major driver is the unsustainable trade of wildlife. Trade in internationally regulated species gains the most research attention, but this only accounts for a minority of traded species and we risk failing to appreciate the scale and impacts of unregulated legal trade. Despite being legal, trade puts pressure on wild species via direct collection, introduced pathogens, and invasive species. Smaller species-rich vertebrates, such as reptiles, fish, and amphibians, may be particularly vulnerable to trading because of gaps in regulations, small distributions, and demand of novel species. Here, we combine data from five sources: online web searches in six languages, Convention on International Trade in Endangered Species (CITES) trade database, Law Enforcement Management Information System (LEMIS) trade inventory, IUCN assessments, and a recent literature review, to characterise the global trade in amphibians, and also map use by purpose including meat, pets, medicinal, and for research. We show that 1215 species are being traded (17% of amphibian species), almost three times previous recorded numbers, 345 are threatened, and 100 Data Deficient or unassessed. Traded species origin hotspots include South America, China, and Central Africa; sources indicate 42% of amphibians are taken from the wild. Newly described species can be rapidly traded (mean time lag of 6.5 years), including threatened and unassessed species. The scale and limited regulation of the amphibian trade, paired with the triptych of connected pressures (collection, pathogens, invasive species), warrants a re-examination of the wildlife trade status quo, application of the precautionary principle in regard to wildlife trade, and a renewed push to achieve global biodiversity goals.

Hughes, Alice C.↗

NASA's Fire Information for Resource Management System (FIRMS): Near Real-Time Global Fire Monitoring Using Data from MODIS and VIIRS

NASA's Fire Information for Resource Management System (FIRMS) provides near-real time active fire / hotspot products from MODIS and VIIRS to users in over 160 countries. The goal of FIRMS is to meet the needs of natural resource and protected area managers that face considerable challenges in obtaining timely satellite-derived information on fires burning within and around their management area. FIRMS has been reliably providing active fire / hotspot data in easy to use formats since its inception in 2006. Fire information is provided through a web map interface, email alerts, a web mapping service, and a range of downloadable files (SHP, CSV, KML and JSON). FIRMS data are used directly by end users and by brokers who take the data and add value to it before re-distributing it.FIRMS was initially developed by the University of Maryland in 2006; it was funded by the United Nations FAO and NASA's Applied sciences program under a NASA ROSES call. In 2012 FIRMS became integrated in to NASA's Land Atmosphere Near real-time Capability for EOS (LANCE); a virtual system that leverages NASAs existing science processing capabilities to deliver NRT data from ten instruments within 3 hours of satellite overpass. This presentation will describe the FIRMS system, provide an overview of the system, briefly describe some of the known applications and describe plans to further integrate the data in to NASA's Global Imagery Browse Services (GIBS) public mapping services and Worldview website.

active fire/hotspots↗

Quantitative and three-dimensional assessment of holdup material

Nuclear material deposited in equipment, transfer lines, and ventilation systems of a processing facility is usually referred to as holdup. Operators need to know the location and amount of holdup in their facility for radiation safety and material accountability. In this work, we propose to use an array of detectors co-axial to the inspected pipe to measure the holdup material. This method is implementable into an automated system capable of crawling on surfaces and pipes of various curvatures, which would enable faster, easier, and more accurate holdup safeguards measurements. We first demonstrated that the current holdup assay procedure could lead to a non-negligible bias in the estimate of special nuclear material mass, due to the simplified assumption of deposited geometry introduced by the Generalized Geometry Holdup (GGH) model. The new approach consists of imaging the inner holdup material by characterizing the detector array’s response and unfolding it from the measured light output. Our experimental proof of principle consists of three NaI(Tl) detectors surrounding an aluminum pipe containing two cesium-137 ( 137 Cs) sources. We derived the source distribution inside the pipe by first calculating the detector response matrix using a method adaptive to the surface geometry of the object containing the measured holdup material. Creating a matrix of the detector array’s measured counts, we then proceed to solve an inverse problem, resulting in an accurately located source position and activity distribution within the response matrix’s spatial resolution. Furthermore, we then developed a simulated model of the envisioned experimental setup, which accurately described both the activity and position of the source in 2D. Finally, we extended our model onto a discretized three-dimensional model of the system, encompassing 36 detectors. The model was simulated to measure the source distribution and activity of multiple sources in pipes of varied geometries, which could then be conveniently translated to a real-time holdup measurement protocol. For the 3D simulation of four different source geometries, the model accurately localized the source position in 3D, while the activity retained a maximum relative error of ±5.32%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cybersecurity Governance

Cybersecurity governance helps an organization detect, prevent, and respond to cyber incidents by establishing cybersecurity policies and procedures for use across the enterprise. As modern energy systems become increasingly reliant on smaller and decentralized generation sources-equipped with complex, data-driven communications-governance will be of growing importance for the continued protection of the electric grid. This presentation sheds light on the important aspects of cybersecurity governance, best practices to ensure a culture of cybersecurity, and approaches to frequent monitoring and assessment of an organization's cybersecurity posture.

business requirements↗

Confined-Pyrolysis as an Experimental Method for Hydrothermal Organic Synthesis

A closed pyrolysis system has been developed as a tool for studying the reactions of organic compounds under extreme hydrothermal conditions. Small high pressure stainless steel vessels in which the ratio of sediment or sample to water has been adjusted to eliminate the headspace at peak experimental conditions confines the organic components to the bulk solid matrix and eliminates the partitioning of the organic compounds away from the inorganic components during the experiment. Confined pyrolysis experiments were performed to simulate thermally driven catagenetic changes in sedimentary organic matter using a solids to water ratio of 3.4 to 1. The extent of alteration was measured by monitoring the steroid and triterpenoid biomarkers and polycyclic aromatic hydrocarbon distributions. These pyrolysis experiments duplicated the hydrothermal transformations observed in nature. Molecular probe experiments using alkadienes, alkenes and alkanes in H2O and D2O elucidated the isomerization and hydrogenation reactions of aliphatic and the competing oxidative reactions occurring under hydrothermal conditions. This confined pyrolysis technique is being applied to test experiments on organic synthesis of relevance to chemical evolution for the origin of life.

Leif, Roald N.↗

A Novel Technique for Performing Space Based Radiation Dosimetry Using DNA: Results from GRaDEx-I and the Design of GRaDEx-II

Because of the large amounts of cosmic radiation in the space environment relative to that on earth, the effects of radiation on the physiology of astronauts is of major concern. Doses of radiation which can cause acute or chronic biological effects are to be avoided, therefore determination of the amount of radiation exposure encountered during space flight and assessment of its impact on biological systems is critical. Quantifying the radiation dosage and damage to biological systems, especially to humans during repetitive high altitude flight and during long duration space flight is important for several reasons. Radiation can cause altered biosynthesis and long term genotoxicity resulting in cancer and birth defects, etc. Radiation damage to biological systems depends in a complex way on incident radiation species and their energy spectra. Typically non-biological, i.e. film or electronic monitoring systems with narrow energy band sensitivity are used to perform dosimetry and then results are extrapolated to biological models. For this reason it may be desirable to perform radiation dosimetry by using biological molecules e.g. DNA or RNA strands as passive sensors. A lightweight genotoxicology experiment was constructed to determine the degree to which in-vitro naked DNA extracted from tissues of a variety of vertebrate organisms is damaged by exposure to radiation in a space environment. The DNA is assayed by means of agarose gel electrophoresis to determine damage such as strand breakage caused by high momentum particles and photons, and base oxidation caused by free radicals. The length distribution of DNA fragments is directly correlated with the radiation dose. It is hoped that a low mass, low cost, passive biological system to determine dose-response relationship (increase in strand breaks with increase in exposure) can be developed to perform radiation dosimetry in support of long duration space flight, and to predict negative effects on biological systems (e.g. astronauts and greenhouses) in space. The payload was flown in a 2.5 cubic foot Get Away Special (GAS) container through NASA's GAS program. It was subjected to the environment of the space shuttle cargo bay for the duration of the STS-91 mission (9 days). Results of the genotoxicology and radiation dosimetry experiment (GRaDEx-I) as well as the design of an improved follow on payload are presented.

Ritter, Joe↗