Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “decision model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Evaluation of dual-weighted residual and machine learning error estimation for projection-based reduced-order models of steady partial differential equations

Projection-based reduced-order models (pROMs) show great promise as a means to accelerate many-query applications such as forward error propagation, solving inverse problems, and design optimization. In order to deploy pROMs in the context of high-consequence decision making, accurate error estimates are required to determine the region(s) of applicability in the parameter space. The following paper considers the dual-weighted residual (DWR) error estimate for pROMs and compares it to another promising pROM error estimate, machine learned error models (MLEM). Here, we show how DWR can be applied to ROMs and then evaluate DWR on two partial differential equations (PDEs): a two-dimensional linear convection–reaction–diffusion equation, and a three-dimensional static hyper-elastic beam. It is shown that DWR is able to estimate errors for pROMs extrapolating outside of their training set while MLEM is best suited for pROMs used to interpolate within the pROM training set.

42 ENGINEERING↗

Packages of Distributed Energy Technologies Demonstrating Demand Flexibility at Community Scale

The combination of increased electric load growth across all sectors, deferred electrical infrastructure investment, and other factors resulting in variable electric power supply, has created technical challenges to maintaining a resilient and reliable grid. Many federal, regional, and local efforts are in play to modernize the electric grid, including advancing building technologies and distributed energy resources (DERs) that are utilizing smarter controls to become responsive to both occupant and grid needs. This report reviews ten pilot projects demonstrating how groups of buildings combined with behind-the-meter (BTM) DERs such as electric vehicle (EV) charging, battery storage, flexible HVAC and domestic hot water systems, and photovoltaic systems can reliably and cost effectively provide grid services. Each of the ten pilot projects aim to deliver both energy efficiency and demand flexibility (DF) while supporting load growth. The ten demonstration teams are piloting flexible DER packages across diverse communities of residential and commercial buildings to address a variety of regional grid needs. The outcomes of these pilot projects will be used to inform future scaling through utility program development. This paper characterizes the ten teams, showcasing the decision-making process used by each group to develop their packages (Section 2), the grid services they plan to deliver (Section 3), the types of DER packages selected for deployment within building sectors (Section 4) and trends between building sector, DER types, and grid services In order to achieve community scale benefits, the pilot projects must utilize aggregated control mechanisms for coordinating buildings and DERs together. Several types of coordinated control architectures have evolved amongst the teams, influenced by use type, existing market conditions, and integration type. Three coordinated controls architectures have been characterized, highlighting their use cases, benefits, challenges, and tradeoffs in their design. These insights can aid utilities, control vendors, and developers in scaling community-level energy systems (Paul, 2024). Ultimately, the technology packages selected by the ten teams will be coordinated to provide power system services, also known as grid services. Insights from these demonstrations will be useful for grid operators, regulators, aggregators and other stakeholders as they look to deploy demand flexible resources as grid services in the future. The grid services that each team is targeting for demonstration are described in Section 3 and Section 4. Methods for evaluating the grid services have been described in the paper Metrics for Evaluating Grid Service Provision from Communities of Grid-interactive and Efficient Buildings and other DER (MacDonald, 2023). To identify technology packages for demonstration, Section 2 shows that project teams used a range of analysis approaches, including building energy modeling, AMI data analysis, cost-benefit frameworks, and utility pilot data. Some teams emphasized technical modeling to quantify grid impacts and demand reduction potential, while others prioritized economic evaluations, stakeholder input, or exploratory pilots to inform deployment decisions. This diversity reflects the need to tailor selection methods to project goals, available data, and organizational context. Section 5 discusses trends between the DER technologies deployed and the grid service provisions from each team. Residential buildings (multifamily and single family) lean towards technologies that enhance energy efficiency (e.g. weatherization upgrades, smart thermostats) and onsite power generation integration (e.g. solar PV). Commercial building demonstrations prioritize technologies that ensure operational reliability (e.g. battery storage) and centralized energy management systems and optimization solutions. Teams that are deploying controllable storage-based technologies are more likely to provide grid services that require a near real-time response. Teams incorporating load shifting technologies like smart thermostats with HEMs are likely to include energy markets participation and customer bill management offerings. Campus demonstrations are adopting diverse sets of DERs to emphasize renewable generation, paired with centralized control. This section also describes technologies that were considered during project planning but ultimately excluded from final deployment. These demonstrations reveal that effective DER package design should be tailored to building type, customer segment, and construction vintage. Multifamily buildings benefit from centralized HVAC upgrades and supervisory controls, while single-family homes are well-suited for individualized technologies like solar, storage, and smart home energy monitors. Commercial and campus settings prioritize EMIS integration and load optimization. New construction enables cost-effective integration of DER-ready infrastructure, whereas retrofits require deployments aligned with owner and tenant value streams. For utility program planners, early coordination with developers and building owners, paired with segmented and modular program offerings, can improve adoption, scalability, and grid impact.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Sensitivity of Wind Turbine Array Downstream Effects to the Parameterization Used in WRF

The Weather Research and Forecasting (WRF) Model has been extensively used for wind energy applications, and current releases include a scheme that can be applied to examine the effects of wind turbine arrays on the atmospheric flow and electricity generation from wind turbines. Herein we present a high-resolution simulation using two different wind farm parameterizations: 1) the “Fitch” parameterization that is included in WRF releases and 2) the recently developed Explicit Wake Parameterization (EWP) scheme. We compare the schemes using a single yearlong simulation for a domain centered on the highest density of current turbine deployments in the contiguous United States (Iowa). Pairwise analyses are applied to diagnose the downstream wake effects and impact of wind turbine arrays on near-surface climate conditions. On average, use of the EWP scheme results in small-magnitude wake effects within wind farm arrays and faster recovery of full WT array wakes. This in turn leads to smaller impacts on near-surface climate variables and reduced array–array interactions, which at a systemwide scale lead to summertime capacity factors (i.e., the electrical power produced relative to nameplate installed capacity) that are 2%–3% higher than those from the more commonly applied Fitch parameterization. It is currently not possible to make recommendations with regard to which wind farm parameterization exhibits higher fidelity or to draw inferences with regard to whether the relative performance may vary with prevailing climate conditions and/or wind turbine deployment configuration. However, the sensitivities documented herein to the wind farm parameterization are of sufficient magnitude to potentially influence wind turbine array siting decisions. Thus, our research findings imply high value in undertaking combined long-term high-fidelity observational studies in support of model validation and verification.

17 WIND ENERGY↗

Latent Space Dynamics Identification

LaSDI is a data-driven physical simulation software that forms a latent space for a given high-fidelity model and discovers a set of ordinary differential equations for the latent space dynamics. It allows a fast and accurate solution process, which is useful for multi-query decision making applications, such as design optimization and uncertainty quantification. The performance of the LaSDI framework is demonstrated on four different problems, i.e., 1D and 2D Burgers equations, nonlinear heat conduction, and radial advection problems. Both linear and nonlinear compression techniques, such as neural network and proper orthogonal decomposition, are used to form a latent space. A concept of local dynamics identification procedure is introduced to enable a parametric model, which enhances the accuracy level over a given parameter space.

Fries, William↗

Modeling backgrounds for the majorana demonstrator

The MAJORANA DEMONSTRATOR is a neutrinoless double-beta decay (0?ß ß ) experiment containing ~30 kg of p-type point contact germanium detectors enriched to 88% in 76Ge and ~14 kg of natural germanium detectors. The detectors are housed in two electroformed copper cryostats and surrounded by a graded passive shield with active muon veto. An extensive radioassay campaign was performed prior to installation to insure the use of ultra-clean materials. The DEMONSTRATOR achieved one of the lowest background rates in the region of the 0?ß ß Q-value, 15.7 ± 1.4 cts/(FWHM t y) from the low-background configuration spanning most of the 64.5 kg-yr active exposure. Nevertheless this background rate is a factor of five higher than the projected background rate. This discrepancy arises from an excess of events from the 232Th decay chain. Background model fits aim to understand this deviation from assay-based projections, potentially determine the source(s) of observed backgrounds, and allow a precision measurement of the two-neutrino double-beta decay half-life. The fits agree with earlier simulation studies, which indicate the origin of the 232Th excess is not from a near-detector component and have informed design decisions for the next-generation LEGEND experiment. Recent findings have narrowed the suspected locations for the excess activity, motivating a final simulation and assay campaign to complete the background model.

Haufe, Christopher R.↗

Enhanced Surgical Decision-Making Tools in Breast Cancer: Predicting 2-Year Postoperative Physical, Sexual, and Psychosocial Well-Being following Mastectomy and Breast Reconstruction (INSPiRED 004)

Background: We sought to predict clinically meaningful changes in physical, sexual, and psychosocial well-being for women undergoing cancer-related mastectomy and breast reconstruction 2 years after surgery using machine learning (ML) algorithms trained on clinical and patient-reported outcomes data. Patients and Methods: We used data from women undergoing mastectomy and reconstruction at 11 study sites in North America to develop three distinct ML models. We used data of ten sites to predict clinically meaningful improvement or worsening by comparing pre-surgical scores with 2 year follow-up data measured by validated Breast-Q domains. We employed ten-fold cross-validation to train and test the algorithms, and then externally validated them using the 11th site’s data. We considered area-under-the-receiver-operating-characteristics-curve (AUC) as the primary metric to evaluate performance. Results: Overall, between 1454 and 1538 patients completed 2 year follow-up with data for physical, sexual, and psychosocial well-being. In the hold-out validation set, our ML algorithms were able to predict clinically significant changes in physical well-being (chest and upper body) (worsened: AUC range 0.69–0.70; improved: AUC range 0.81–0.82), sexual well-being (worsened: AUC range 0.76–0.77; improved: AUC range 0.74–0.76), and psychosocial well-being (worsened: AUC range 0.64–0.66; improved: AUC range 0.66–0.66). Baseline patient-reported outcome (PRO) variables showed the largest influence on model predictions. Conclusions: Machine learning can predict long-term individual PROs of patients undergoing postmastectomy breast reconstruction with acceptable accuracy. This may better help patients and clinicians make informed decisions regarding expected long-term effect of treatment, facilitate patient-centered care, and ultimately improve postoperative health-related quality of life.

60 APPLIED LIFE SCIENCES↗

Evolution of Electric Sector Water Use Under Alternative Electricity Futures

Increasing competition for water resources in the United States could create future challenges for allocating and using thermal cooling water in the U.S. electric power sector. While thermal power plant retirements and the growth of wind and solar technologies can reduce national aggregate power sector cooling water use, local water constraints and growing demand for agricultural or municipal supply could create greater needs for higher-cost alternative water supplies such as groundwater or recycled wastewater. For some regions, these incentives could change future electricity planning and operational decisions. These relationships and impacts are studied here using the National Renewable Energy Laboratory (NREL) Regional Energy Deployment System (ReEDS), a national electric sector planning model that has recently been upgraded to include a highly detailed representation of thermal cooling water demand and supply. Thermal power technologies are differentiated by both cooling technology and water source type to track and constrain thermal cooling water use in a way that incorporates both physical and legal water considerations in the United States. This capability is exercised under a range of electricity sector futures with alternative technology costs, fuel prices, and water constraints to illustrate ways that U.S. electric sector water use could evolve under uncertain future electric sector drivers. In exploring changes to regional generation and transmission planning and operation, water requirements, and cost, we highlight the environmental and economic impacts of future power sector water decisions.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Searches for direct slepton production in the compressed-mass corridor in $\sqrt{\textrm{s}}$ = 13 TeV pp collisions with the ATLAS detector

This paper presents searches for the direct pair production of charged light-flavour sleptons, each decaying into a stable neutralino and an associated Standard Model lepton. The analyses focus on the challenging ``corridor'' region, where the mass difference, $Δm$, between the slepton ($\tilde{e}$ or $\tildeμ$) and the lightest neutralino ($\tildeχ^{0}_{1}$) is less or similar to the mass of the $W$ boson, $m(W)$, with the aim to close a persistent gap in sensitivity to models with $Δm \lesssim m(W)$. Events are required to contain a high-energy jet, significant missing transverse momentum, and two same-flavour opposite-sign leptons ($e$ or $μ$). The analysis uses $pp$ collision data at $\sqrt{s} = 13$ TeV recorded by the ATLAS detector, corresponding to an integrated luminosity of 140 fb$^{-1}$. Several kinematic selections are applied, including a set of boosted decision trees. These are each optimised for different $Δm$ to provide expected sensitivity for the first time across the full $Δm$ corridor. The results are generally consistent with the Standard Model, with the most significant deviations observed with a local significance of 2.0 $σ$ in the selectron search, and 2.4 $σ$ in the smuon search. While these deviations weaken the observed exclusion reach in some parts of the signal parameter space, the previously present sensitivity gap to this corridor is largely reduced. Constraints at the 95% confidence level are set on simplified models of selectron and smuon pair production, where selectrons (smuons) with masses up to 300 (350) GeV can be excluded for $Δm$ between 2 GeV and 100 GeV.

hadron-hadron scattering↗

Co-Simulation Model for Optimal Wind-Hydro Coordination Using Wind Farm Control Dynamics

The growing share of Variable Renewable Energy sources (VRES) in power systems presents challenges for regula- tors, grid operators and energy producers. The VRES’ operation has limited flexibility in their operations, as they are highly dependent on ambient environments. To address these challenges, decision-makers must consider multiple objectives, among these are revenue, power system services and mechanical load on wind turbines. Coordinated operation of power plants and different wind farm control strategies are examples of measures that can benefit these objectives. This study proposes a Multi-Objective Linear Programming (MOLP) model to simulate the optimum operation of wind and hydropower plants that share limited transmission capacity. Further, wind farm control dynamics are included to obtain realistic output power and accumulated damage. From this, a case study based on a relevant location in Norway is presented to analyze the improved effect of wind- hydro coordination and wind farm control in achieving the objectives of accumulated wind turbine damage and total revenue of the hybrid power system. In addition, the study considers the potential advantages of adding a variable-speed pump to the hydropower plant. The results demonstrate that by considering multiple objectives in the optimization, one may achieve better overall performance of the objectives. By utilizing the flexibility of hydro storage, the decision maker may adjust to obtain the most desired outcome. Moreover, the added flexibility of utilizing a pump for hydro storage shows great improvements for the combined revenue of the power plants and reduced curtailment of the wind farm. However, less impact is observed from using a variable speed pump compared to a fixed speed pump.

13 HYDRO ENERGY↗

Gaining Perspective on Unconventional Well Design Choices through Play-level Application of Machine Learning Modeling

The recent development of unconventional oil and gas (O&G) reservoirs has led to an abundant hydrocarbon supply, both domestically and globally. However, there is a continued push to develop new and innovative approaches to improve exploration and extraction efficiencies and overall well productivity moving forward. Substantial improvements in unconventional O&G development are expected through optimized well completion and stimulation strategies aimed at maximizing well productivity. Optimizing well designs will require tailoring to the distinctive geologic conditions present for any newly placed well. To better evaluate the impact of well design attributes and their associated interactions on productivity in a major unconventional play, multivariate machine learning-based models that use empirical datasets were developed. A gradient boosted regression tree (GBRT) algorithm was applied. GBRT has been narrowly investigated for O&G applications but enables straightforward parametric importance and influence evaluation, as well as assessment of parameter interaction effects. Models were trained on well design and locational parameters that serve as a proxy for variable geologic conditions to estimate two types of productivity indicator response variables strongly correlated to estimated ultimate recovery (EUR). The dataset utilized consists of over 7,000 well observations that cover the majority of the productive region of the Marcellus Shale. Model performance was evaluated and algorithm parameters tuned by analyzing the goodness-of-fit for simulated results against observed data in a cross-validation approach. Models were found capable of 73–79 percent prediction accuracy on held out testing data of gas equivalent production and can be used to inform future well design and placement decisions for increasing EUR per well and improving overall field-level recovery. Study results indicate that Marcellus well performance improves most with upscaling perforated interval lengths and water and proppant volumes per foot; but relative productivity improvements are spatially dependent across the play. Finally, optimal combinations of water and proppant on well performance were found to vary depending on well location, emphasizing the utility of data-driven models capable of broad application across a play of interest for informing tailored well design approaches prior to their field deployment.

04 OIL SHALES AND TAR SANDS↗

Inter-Domain Fusion for Enhanced Intrusion Detection in Power Systems: An Evidence Theoretic and Meta-Heuristic Approach

False alerts due to misconfigured or compromised intrusion detection systems (IDS) in industrial control system (ICS) networks can lead to severe economic and operational damage. However, research using deep learning to reduce false alerts often requires the physical and cyber sensor data to be trustworthy. Implicit trust is a major problem for artificial intelligence or machine learning (AI/ML) in cyber-physical system (CPS) security, because when these solutions are most urgently needed is also when they are most at risk (e.g., during an attack). To address this, the Inter-Domain Evidence theoretic Approach for Inference (IDEA-I) is proposed that reframes the detection problem as how to make good decisions given uncertainty. Specifically, an evidence theoretic approach leveraging Dempster–Shafer (DS) combination rules and their variants is proposed for reducing false alerts. A multi-hypothesis mass function model is designed that leverages probability scores obtained from supervised-learning classifiers. Using this model, a location-cum-domain-based fusion framework is proposed to evaluate the detector’s performance using disjunctive, conjunctive, and cautious conjunctive rules. The approach is demonstrated in a cyber-physical power system testbed, and the classifiers are trained with datasets from Man-In-The-Middle attack emulation in a large-scale synthetic electric grid. For evaluating the performance, we consider plausibility, belief, pignistic, and general Bayesian theorem-based metrics as decision functions. To improve the performance, a multi-objective-based genetic algorithm is proposed for feature selection considering the decision metrics as the fitness function. Finally, we present a software application to evaluate the DS fusion approaches with different parameters and architectures.

42 ENGINEERING↗

Multidisciplinary design optimization in Architecture, Engineering, and Construction: a detailed review and call for collaboration

The design of buildings has become a complex and multidisciplinary problem involving multiple conflicting objectives as architects and designers address competing technical, economic, environmental, and societal concerns. This has been driving research in Architecture, Engineering, and Construction (AEC) toward rigorous multidisciplinary decision-making frameworks that generate and evaluate numerous design alternatives using multi-objective optimization in concert with simulation and analysis models of varying fidelity and computational expense. While such frameworks are well known and widely employed in the aerospace and systems engineering domains, efforts by design professionals and researchers in the AEC field are scattered at best. In this paper, we provide a detailed review of recent developments in optimization frameworks in the AEC field and subsequently highlight how such developments are largely compartmentalized into separate domains such as structural, energy, daylighting, and other performance factors. Herein, we further discuss the technical challenges involved in concurrent coupled multidisciplinary design optimization (MDO) in the AEC field such as interoperability issues between Building Information Modeling (BIM) environments, analysis/simulation tools, and optimization frameworks. We conclude by outlining research needed for more unified modeling and simulation-based optimization frameworks to aid in complex and multidisciplinary building design processes. We also highlight the need for the identification and development of multi-fidelity simulation tools for use across multiple design phases. As such, this paper contributes a novel roadmap to leverage aerospace and systems engineering research in MDO into the field of AEC, along with a call for researchers in the MDO community to seek collaborations in AEC field.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A hybrid architecture for volt-var control in active distribution grids

Modern active distribution grids are characterized by the increasing penetration of distributed energy resources (DERs). The proper coordination and scheduling of a large numbers of these small-scale and spatially distributed DERs is necessary, and warrants the use of novel distributed approaches. In this paper, we propose a hybrid volt-var control architecture for the distribution grid, which leverages existing centralized and local approaches to planning, decision making, and control, and augments it with distributed optimization and distributed control for DER management. First, we propose a convex model to describe the power physics of distribution grids of meshed topology and unbalanced structure, based on current injection and McCormick Envelopes. Second, we employ the distributed proximal atomic coordination (PAC) algorithm to coordinate DERs to provide voltage support. We implement volt-var optimization by optimally coordinating DERs including PV smart inverters and demand response. We present results using the IEEE-34 bus network, using real data from a distribution feeder in Hawaii, to model load and PV generation. Different levels of DER penetration and objective functions are simulated. Finally, our results show the need for the coordination of DERs to improve voltage profiles, even in networks with existing voltage control devices. Further, we show the need for flexible reactive power capabilities to achieve desired grid performance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Navigating the Noise: Bringing Clarity to ML Parameterization Design With O $\boldsymbol{\mathcal{O}}$(100) Ensembles

Abstract Machine‐learning (ML) parameterizations of subgrid processes (here of turbulence, convection, and radiation) may one day replace conventional parameterizations by emulating high‐resolution physics without the cost of explicit simulation. However, uncertainty about the relationship between offline and online performance (i.e., when integrated with a large‐scale general circulation model) hinders their development. Much of this uncertainty stems from limited sampling of the noisy, emergent effects of upstream ML design decisions on downstream online hybrid simulation. Our work rectifies the sampling issue via the construction of a semi‐automated, end‐to‐end pipeline for size ensembles of hybrid simulations, revealing important nuances in how systematic reductions in offline error manifest in changes to online error and online stability. For example, removing dropout and switching from a Mean Squared Error to a Mean Absolute Error loss both reduce offline error, but they have opposite effects on online error and online stability. Other design decisions, like incorporating memory, converting moisture input from specific humidity to relative humidity, using batch normalization, and training on multiple climates do not come with any such compromises. Finally, we show that ensemble sizes of may be necessary to reliably detect causally relevant differences online. By enabling rapid online experimentation at scale, we can empirically settle debates regarding subgrid ML parameterization design that would have otherwise remained unresolved in the noise.

Lin, Jerry [Department of Earth System Sciences Un↗

Multi-model Hydroclimate Projections for the Alabama-Coosa-Tallapoosa River Basin in the Southeastern United States

Abstract This study uses a high-resolution, process-based modeling framework to assess the impacts of changing climate on water resources for the Alabama-Coosa-Tallapoosa River Basin in the southeastern United States. A 33-member ensemble of hydrologic projections was generated using 3 distributed hydrologic models (Precipitation-Runoff Modeling System, Variable Infiltration Capacity, and Distributed Hydrology Soil Vegetation Model) of different complexity. These hydrologic models were driven by dynamically downscaled and bias-corrected future climate simulations from 11 Coupled Model Intercomparison Project Phase 5 global climate models under Representative Concentration Pathway 8.5 emission scenario, with 40 years each in baseline (1966–2005) and future (2011–2050) periods. The hydroclimate response, in general, projects an increase in mean seasonal precipitation, runoff, and streamflow. The high and low flows are projected to increase and decrease, respectively, in general, suggesting increased likelihood of extreme rainfall events and intensification of the hydrologic cycle. The uncertainty associated with the ensemble hydroclimate response, analyzed through an analysis of variance technique, suggests that the choice of climate model is more critical than the choice of hydrologic model for the studied region. This study provides in-depth insights of hydroclimate response and associated uncertainties to support informed decisions by water resource managers.

54 ENVIRONMENTAL SCIENCES↗

Impact of High-Reactivity Advanced Test Reactor Experiments on Photon Heating in Nearby Experiment Locations

The Advanced Test Reactor’s (ATR’s) distinctive ability to provide a wide range of irradiation conditions is attractive for programs pursuing fuel qualification experiments. These potentially high-fuel-load experiments are a relatively new development and produce unexplored effects on nearby experiments. Here, this paper explores how photon heating of such an experiment may affect other nearby experiment programs, ultimately serving to better inform decisions regarding experiment design and risks to programmatic goals. The MC21 (Monte Carlo for the 21st Century) code is used to model and study how gamma heat generation rates and axial effects impact different ATR positions. The results reveal that the proximity of a given experiment’s position to the high-fuel-load one can significantly alter that experiment’s expected axial profile.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Accelerating data acquisition with FPGA-based edge machine learning: a case study with LCLS-II

New scientific experiments and instruments generate vast amounts of data that need to be transferred for storage or further processing, often overwhelming traditional systems. Edge machine learning (EdgeML) addresses this challenge by integrating machine learning (ML) algorithms with edge computing, enabling real-time data processing directly at the point of data generation. EdgeML is particularly beneficial for environments where immediate decisions are required, or where bandwidth and storage are limited. In this paper, we demonstrate a high-speed configurable ML model in a fully customizable EdgeML system using a field programmable gate array (FPGA). Our demonstration focuses on an angular array of electron spectrometers, referred to as the ‘CookieBox,’ developed for the Linac Coherent Light Source II project. The EdgeML system captures 51.2 Gbps from a 6.4 GS s −1 analog to digital converter and is designed to integrate data pre-processing and ML inside an FPGA. Our implementation achieves an inference latency of 0.2 µs for the ML model, and a total latency of 0.4 µs for the complete EdgeML system, which includes pre-processing, data transmission, digitization, and ML inference. The modular design of the system allows it to be adapted for other instrumentation applications requiring low-latency data processing.

97 MATHEMATICS AND COMPUTING↗

Detection and Diagnosis of Data Integrity Attacks in Solar Farms Based on Multilayer Long Short-Term Memory Network

Photovoltaic (PV) systems are becoming more vulnerable to cyber threats. In response to this emerging concern, developing cyber-secure power electronics converters has received increased attention from the IEEE Power Electronics Society that recently launched a cyber-physical-security initiative. Here this letter proposes a deep sequence learning based diagnosis solution for data integrity attacks on PV systems in smart grids, including dc–dc and dc–ac converters. The multilayer long short-term memory networks are used to leverage time-series electric waveform data from current and voltage sensors in PV systems. The proposed method has been evaluated in a PV smart grid benchmark model with extensive quantitative analysis. As a comparison, we have evaluated classic data-driven methods, including K-nearest neighbor, decision tree, support vector machine, artificial neural network, and convolutional neural network. Comparison results verify performances of the proposed method for detection and diagnosis of various data integrity attacks on PV systems.

42 ENGINEERING↗