Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cryogenics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

On 32-GHz cryogenically cooled HEMT low-noise amplifiers

The cryogenic noise temperature performance of a two-stage and a three-stage 32 GHz High Electron Mobility Transistor (HEMT) amplifier was evaluated. The amplifiers employ 0.25 micrometer conventional AlGaAs/GaAs HEMT devices, hybrid matching input and output microstrip circuits, and a cryogenically stable dc biasing network. The noise temperature measurements were performed in the frequency range of 31 to 33 GHz over a physical temperature range of 300 K down to 12 K. Across the measurement band, the amplifiers displayed a broadband response, and the noise temperature was observed to decrease by a factor of 10 in cooling from 300 K to 15 K. The lowest noise temperature measured for the two-stage amplifier at 32 GHz was 35 K with an associated gain of 16.5 dB, while the three-stage amplifier measured 39 K with an associated gain of 26 dB. It was further observed that both amplifiers were insensitive to light.

Bautista, J. J.↗

Test techniques: A survey paper on cryogenic tunnels, adaptive wall test sections, and magnetic suspension and balance systems

The ability to get good experimental data in wind tunnels is often compromised by things seemingly beyond our control. Inadequate Reynolds number, wall interference, and support interference are three of the major problems in wind tunnel testing. Techniques for solving these problems are available. Cryogenic wind tunnels solve the problem of low Reynolds number. Adaptive wall test sections can go a long way toward eliminating wall interference. A magnetic suspension and balance system (MSBS) completely eliminates support interference. Cryogenic tunnels, adaptive wall test sections, and MSBS are surveyed. A brief historical overview is given and the present state of development and application in each area is described.

Kilgore, Robert A.↗

Design of a flexure mount for optics in dynamic and cryogenic environments

The design of a flexure mount for a mirror operating in a cryogenic environment is presented. This structure represents a design effort recently submitted to NASA Ames for the support of the primary mirror of the Space Infrared Telescope Facility (SIRTF). The support structure must passively accommodate the differential thermal contraction between the glass mirror and the aluminium structure of the telescope during cryogenic cooldown. Further, it must support the one meter diameter, 116 kilogram (258 pound) primary mirror during a severe launch to orbit without exceeding the micro-yield of the material anywhere in the flexure mount. Procedures used to establish the maximum allowable radial stiffness of the flexural mount, based on the finite element program NASTRAN and the optical program FRINGE, are discussed. Early design concepts were evaluated using a parametric design program, and the development of that program is presented. Dynamic loading analyses performed with NASTRAN are discussed. Methods of combining modal responses resulting from a displacement response spectrum analysis are discussed, and a combination scheme called MRSS, modified root of sum of squares, is presented. Model combination schemes using MRSS, SRSS, and ABS are compared to the results of the modal frequency response analysis performed with NASTRAN.

Pollard, Lloyd Wayne↗

COLD-SAT: Cryogenic On-Orbit Liquid Depot-Storage, Acquisition and Transfer

NASA is entering an era of expanded space activity. Space-based transportation systems will carry cargo and humans from low earth orbit to geosynchronous orbit, to lunar bases, and to the Martian surface. Support of these future missions will require new, long lived, on-orbit systems using subcritical cryogens for propellants and life support systems. Such on-orbit systems present low gravity fluid management challenges of long term storage and efficient fluid transfer and supply techniques. Development of these cryogenic systems requires on-orbit experimentation to demonstrate the capability of performing these fluid management tasks and to obtain the engineering data base required to correlate analytical tools used for system design.

Source record↗

Surface tension confined liquid cryogen cooler

A cryogenic cooler is provided for use in craft such as launch, orbital, and space vehicles subject to substantial vibration, changes in orientation, and weightlessness. The cooler contains a small pore, large free volume, low density material to restrain a cryogen through surface tension effects during launch and zero-g operations and maintains instrumentation within the temperature range of 10 to 140 K. The cooler operation is completely passive, with no inherent vibration or power requirements.

Stephen H Castles↗

Cryogenic wind tunnel research - A global perspective

The development of cryogenic wind tunnels is reviewed and 13 cryogenic wind tunnels currently operating in England, France, Germany, Japan, and the U.S. are described. A table illustrating the characteristics of these tunnels is presented, including test gases, test section sizes, speed ranges, stagnation pressure and temperature, and running time. The research conducted using the various wind tunnels is outlined and the operation of each of the tunnels is considered.

Dress, D. A.↗

Cryogenic fluid management technology requirements for the Space Transfer Vehicle

An in-house study was performed to design a cryogenic Space Transfer Vehicle (STV) for the late 1990s that can evolve with the demanding mission requirements of the manned exploration initiatives. An assessment of cryogenic fluid management technology issues associated with the STV was performed to identify technology gaps and propose advanced development activities.

Cramer, John M.↗

X-ray metal film filters at cryogenic temperatures

Thin aluminum foil filters have been evaluated at cryogenic temperatures. The results of the test program, including cold cycling and vibration testing, indicate that these filters are fully successful at cryogenic temperatures and can provide the high X-ray transmittance and high background rejection required for the blocking filters which are being developed for the X-Ray Spectrometer, one of the focal plane instruments on the Advanced X-Ray Astrophysics Facility.

Keski-Kuha, Ritva A. M.↗

32-GHz cryogenically cooled HEMT low-noise amplifiers

The cryogenic noise temperature performance of a two-stage and a three-stage 32 GHz high electron mobility transistor (HEMT) amplifier was evaluated. The amplifiers employ 0.25 micrometer conventional AlGaAs/GaAs HEMT devices, hybrid matching input and output microstrip circuits, and a cryogenically stable dc biasing network. The noise temperature measurements were performed in the frequency range of 31 to 33 GHz over a physical temperature range of 300 K down to 12 K. Across the measurement band, the amplifiers displayed a broadband response, and the noise temperature was observed to decrease by a factor of 10 in cooling from 300 to 15 K. The lowest noise temperature measured for the two-stage amplifier at 32 GHz was 35 K with an associated gain of 16.5 dB, while the three-stage amplifier measured 39 K with an associated gain of 26 dB. It was further observed that both amplifiers were insensitive to light.

Duh, K. H. George↗

Visual-Inspection Probe For Cryogenic Chamber

Visual-inspection probe that resembles borescope enables observer at ambient temperature to view objects immersed in turbulent flow of liquid oxygen, liquid nitrogen, or other cryogenic fluid. Design of probe fairly conventional, except special consideration given to selection of materials and to thermal expansion to provide for expected range of operating temperatures. Penetrates wall of cryogenic chamber to provide view of interior. Similar probe illuminates scene. View displayed on video monitor.

Friend, Steve↗

Advanced Reusable Foam Cryogenic Insulation

Lightweight, reusable cryogenic containers reduce costs of operation of advanced hypersonic airplanes and space launch vehicles. Specimens demonstrated in temperature range of negative 420 to positive 400 degrees F (negative 251 to positive 204 degrees C). Prototype reusable cryogenic foam insulation developed. Consists of two discrete layers of closed-cell polymethacrylimide foam of density 6.9 lb/ft to the 3rd power (111 kg/m to the 3rd power) bonded together with epoxy adhesive. Additionally reinforced with 0.003-in. (0.08-mm)-thick layer of fiberglass cloth. Wrapped with precut and preformed vapor-barrier cover. Such containers useful on Earth in laboratories, factories, and transportation systems.

Taylor, Allan H.↗

Test techniques for cryogenic wind tunnels

Some of the testing techniques developed for transonic cryogenic tunnels are presented. Techniques are emphasized which required special development or were unique because of the opportunities offered by cryogenic operation. Measuring the static aerodynamic coefficients normally used to determine component efficiency is discussed. The first topic is testing of two dimensional airfoils at transonic Mach numbers and flight values of Reynolds number. Three dimensional tests of complete configurations and sidewall mounted wings are also described. Since flight Reynolds numbers are of interest, free transition must be allowed. A discussion is given of wind tunnel and model construction effects on transition location. Time dependent phenomena, fluid mechanics, and measurement techniques are examined. The time dependent, or unsteady, aerodynamic test techniques described include testing for flutter, buffet, and oscillating airfoil characteristics. In describing non-intrusive laser techniques, discussions are given regarding optical access, seeding, forward scatter lasers, two-spot lasers, and laser holography. Methods of detecting transition and separation are reported and a new type of skin friction balance is described.

Lawing, Pierce L.↗

Main results of CAST-10 airfoil tested in T2 cryogenic wind tunnel

The aim of this cooperative NASA/DFVLR/ONERA project was to examine the performance of the CAST-10 airfoil in the T2 cryogenic wind tunnel. Tests included general characteristics of the CAST-10 airfoil and fundamental studies on Reynold number effects. Good T2 cryogenic operation was observed. Improvements should be done for moisture elimination and for side wall boundary layer effects.

Blanchard, A.↗

Liquid Transfer Cryogenic Test Facility: Initial hydrogen and nitrogen no-vent fill data

The Liquid Transfer Cryogenic Test Facility is a versatile testbed for ground-based cryogenic fluid storage, handling, and transfer experimentation. The test rig contains two well instrumented tanks, and a third interchangeable tank, designed to accommodate liquid nitrogen or liquid hydrogen testing. The internal tank volumes are approx. 18, 5, and 1.2 cu. ft. Tank pressures can be varied from 2 to 30 psia. Preliminary no vent fill tests with nitrogen and hydrogen were successfully completed with the test rig. Initial results indicate that no vent fills of nitrogen above 90 percent full are achievable using this test configuration, in a 1-g environment, and with inlet liquid temperatures as high as 143 R, and an average tank wall temperature of nearly 300 R. This inlet temperature corresponds to a saturation pressure of 19 psia for nitrogen. Hydrogen proved considerably more difficult to transfer between tanks without venting. The highest temperature conditions resulting in a fill level greater than 90 percent were with an inlet liquid temperature of 34 R, and an estimated tank wall temperature of slightly more than 100 R. Saturation pressure for hydrogen at this inlet temperature is 10 psia. All preliminary no vent fill tests were performed with a top mounted full cone nozzle for liquid injection. The nozzle produces a 120 degree conical droplet spray at a differential pressure of 10 psi. Pressure in the receiving tank was held to less than 30 psia for all tests.

Moran, Matthew E.↗

Deformation and fracture of thin sheet aluminum-lithium alloys: The effect of cryogenic temperatures

The objective is to characterize the fracture behavior and to define the fracture mechanisms for new Al-Li-Cu alloys, with emphasis on the role of indium additions and cryogenic temperatures. Three alloys were investigated in rolled product form: 2090 baseline and 2090 + indium produced by Reynolds Metals, and commercial AA 2090-T81 produced by Alcoa. The experimental 2090 + In alloy exhibited increases in hardness and ultimate strength, but no change in tensile yield strength, compared to the baseline 2090 composition in the unstretched T6 condition. The reason for this behavior is not understood. Based on hardness and preliminary Kahn Tear fracture experiments, a nominally peak-aged condition was employed for detailed fracture studies. Crack initiation and growth fracture toughness were examined as a function of stress state and microstructure using J(delta a) methods applied to precracked compact tension specimens in the LT orientation. To date, J(delta a) experiments have been limited to 23 C. Alcoa 2090-T81 exhibited the highest toughness regardless of stress state. Fracture was accompanied by extensive delamination associated with high angle grain boundaries normal to the fatigue precrack surface and progressed microscopically by a transgranular shear mechanism. In contrast the two peak-aged Reynolds alloys had lower toughness and fracture was intersubgranular without substantial delamination. The influences of cryogenic temperature, microstructure, boundary precipitate structure, and deformation mode in governing the competing fracture mechanisms will be determined in future experiments. Results contribute to the development of predictive micromechanical models for fracture modes in Al-Li alloys, and to fracture resistant materials.

Wagner, John A.↗

Liquid-Vapor Equilibrium of Multicomponent Cryogenic Systems

Liquid-vapor and solid-vapor equilibria at low to moderate pressures and low temperatures are important in many solar system environments, including the surface and clouds of Titan, the clouds of Uranus and Neptune, and the surfaces of Mars and Triton. The familiar cases of ideal behavior are limiting cases of a general thermodynamic representation for the vapor pressure of each component in a homogeneous multicomponent system. The fundamental connections of laboratory measurements to thermodynamic models are through the Gibbs-Duhem relation and the Gibbs-Helmholtz relation. Using laboratory measurements of the total pressure, temperature, and compositions of the liquid and vapor phases at equilibrium, the values of these parameters can be determined. The resulting model for vapor-liquid equilibrium can then conveniently and accurately be used to calculate pressures, compositions, condensation altitudes, and their dependencies on changing climatic conditions. A specific system being investigated is CH4-C2H6-N2, at conditions relevant to Titan's surface and atmosphere. Discussed are: the modeling of existing data on CH4-N2, with applications to the composition of Titan's condensate clouds; some new measurements on the CH4-C2H6 binary, using a high-precision static/volumetric system, and on the C2H6-N2 binary, using the volumetric system and a sensitive cryogenic flow calorimeter; and describe a new cryogenic phase-equilibrium vessel with which we are beginning a detailed, systematic study of the three constituent binaries and the ternary CH4-C2H6-N2 system at temperatures ranging from 80 to 105 K and pressures from 0.1 to 7 bar.

Thompson, W. Reid↗

On-orbit low gravity cryogenic scientific investigations using the COLD-SAT Satellite

The Cryogenic On-Orbit Liquid Depot Storage, Acquisition and Transfer (COLD-SAT) Satellite is an experimental spacecraft designed to investigate the systems and technologies required for an efficient, effective, and reliable management of cryogenic fluids in reduced-gravity space environment. This paper defines the technology needs and the accompanying experimental three-month baseline mission of the COLD-SAT Satellite; describes the experiment subsystems, major features, and rationale for satisfying primary and secondary experimental requirements, using LH2 as the test fluid; and presents the conceptual design of the COLD-SAT spacecraft subsystems which support the on-orbit experiment.

Bailey, W. J.↗

Surface flow visualization in the cryogenic wind tunnel

The prospects are reviewed of a range of possible surface flow visualization methods for application to model testing in the large cryogenic wind tunnel. Desirable features are outlined, including the flow details which should be revealed by the various methods. The risks of model and tunnel contamination are discussed, also the coverage of the model surface to be expected, the advance planning and complexity of model design and tunnel equipment required by the visualization method, and the prospects of generating multiple flow images during one tunnel run. The techniques range from the untried to several on which already there is some experience in the cryogenic environment. Directions for further development are suggested.

Goodyer, M. J.↗