Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “count data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

PLANETARY CANDIDATES OBSERVED BY KEPLER. III. ANALYSIS OF THE FIRST 16 MONTHS OF DATA

New transiting planet candidates are identified in 16 months (2009 May-2010 September) of data from the Kepler spacecraft. Nearly 5000 periodic transit-like signals are vetted against astrophysical and instrumental false positives yielding 1108 viable new planet candidates, bringing the total count up to over 2300. Improved vetting metrics are employed, contributing to higher catalog reliability. Most notable is the noise-weighted robust averaging of multi-quarter photo-center offsets derived from difference image analysis that identifies likely background eclipsing binaries. Twenty-two months of photometry are used for the purpose of characterizing each of the candidates. Ephemerides (transit epoch, T {sub 0}, and orbital period, P) are tabulated as well as the products of light curve modeling: reduced radius (R {sub P}/R {sub *}), reduced semimajor axis (d/R {sub *}), and impact parameter (b). The largest fractional increases are seen for the smallest planet candidates (201% for candidates smaller than 2 R {sub Circled-Plus} compared to 53% for candidates larger than 2 R {sub Circled-Plus }) and those at longer orbital periods (124% for candidates outside of 50 day orbits versus 86% for candidates inside of 50 day orbits). The gains are larger than expected from increasing the observing window from 13 months (Quarters 1-5) to 16 months (Quarters 1-6) even in regions of parameter space where one would have expected the previous catalogs to be complete. Analyses of planet frequencies based on previous catalogs will be affected by such incompleteness. The fraction of all planet candidate host stars with multiple candidates has grown from 17% to 20%, and the paucity of short-period giant planets in multiple systems is still evident. The progression toward smaller planets at longer orbital periods with each new catalog release suggests that Earth-size planets in the habitable zone are forthcoming if, indeed, such planets are abundant.

79 ASTRONOMY AND ASTROPHYSICS↗

Investigating the uniformity of the excess gamma rays towards the galactic center region

We perform a composite likelihood analysis of subdivided regions within the central 26° × 20° of the Milky Way, with the aim of characterizing the spectrum of the gamma-ray galactic center excess in regions of varying galactocentric distance. Outside of the innermost few degrees, we find that the radial profile of the excess is background-model dependent and poorly constrained. The spectrum of the excess emission is observed to extend upwards of 10 GeV outside ∼5° in radius, but cuts off steeply between 10–20 GeV only in the innermost few degrees. If interpreted as a real feature of the excess, this radial variation in the spectrum has important implications for both astrophysical and dark matter interpretations of the galactic center excess. Single-component dark matter annihilation models face challenges in reproducing this variation; on the other hand, a population of unresolved millisecond pulsars contributing both prompt and secondary inverse Compton emission may be able to explain the spectrum as well as its spatial dependency. We show that the expected differences in the photon-count distributions of a smooth dark matter annihilation signal and an unresolved point source population are an order of magnitude smaller than the fluctuations in residuals after fitting the data, which implies that mismodeling is an important systematic effect in point source analyses aimed at resolving the gamma-ray excess.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurement of the t t ¯ production cross section in the τ + jets final state in p p collisions at s = 8 TeV using the ATLAS detector

A measurement of the inclusive p p → t $\bar{t}$ + X production cross section in the τ + jets final state using only the hadronic decays of the τ lepton is presented. The measurement is performed using 20.2 fb -1 of proton-proton collision data recorded at a center-of-mass energy of √ s = 8 TeV with the ATLAS detector at the Large Hadron Collider. The cross section is measured via a counting experiment by imposing a set of selection criteria on the identification and kinematic variables of the reconstructed particles and jets, and on event kinematic variables and characteristics. The production cross section is measured to be σ t $\bar{t}$ = 239 ± 29 pb , which is in agreement with the measurements in other final states and the theoretical predictions at this center-of-mass energy.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

10 Boron-film-based gas detectors at ESS

The development of detectors for the European Spallation Source is an important parallel element to the effort put into the design and construction of the neutron source and instruments. The 10Boron-film-based detector developments that started over a decade ago as basic detector concepts have now reached technical maturity after intense prototyping work and numerous testing campaigns. Several of the ESS beamlines that will soon enter the commissioning phase started welcoming the detector systems built with the 10 B-film converter technology. The real-size demonstrators evolved in the last 2–3 years into a diverse suite of gas proportional counters for use in diffraction, reflectometry and small-angle scattering studies in spite of the operational complexity posed by the requirements for large-area coverage, low material budget and robustness for operation in the high-flux and high-radiation environment of ESS. The detectors are now being shipped to ESS or undergoing the last performance and calibration tests before being handed over to the instrument teams for installation in the host beamlines. A common feature of these detector systems is the very large number of readout channels that they are instrumented with in order to fulfill the demanding requirements for sensitivity, spatial resolution and count-rate capability. Across all of the detector types that will operate at ESS, the integration, testing and commissioning of the read-out technologies and software tools for data reduction, calibration and analysis are the focus of the detector and integration teams. These will yield a wealth of knowledge about their operation as well as initial results on the in-situ performance, a very important asset to ensure rapid commissioning of the detectors when neutrons from the ESS source become available. In this paper we will give an overview of the 10 B-film-based detector technologies included in the ESS detector suite that are currently facing the transition from the production phase to installation and integration with the other beamline components, which comes with its own specific challenges of both organizational and technical nature.

47 OTHER INSTRUMENTATION↗

ON THE FERMI -GBM EVENT 0.4 s AFTER GW150914

In view of the recent report by Connaughton et al., we analyze continuous time-tagged event (TTE) data of Fermi -gamma-ray burst monitor (GBM) around the time of the gravitational-wave event GW 150914. We find that after proper accounting for low-count statistics, the GBM transient event at 0.4 s after GW 150914 is likely not due to an astrophysical source, but consistent with a background fluctuation, removing the tension between the INTEGRAL /ACS non-detection and GBM. Additionally, reanalysis of other short GRBs shows that without proper statistical modeling the fluence of faint events is over-predicted, as verified for some joint GBM–ACS detections of short GRBs. We detail the statistical procedure to correct these biases. As a result, faint short GRBs, verified by ACS detections, with significances in the broadband light curve even smaller than that of the GBM–GW150914 event are recovered as proper non-zero source, while the GBM–GW150914 event is consistent with zero fluence.

79 ASTRONOMY AND ASTROPHYSICS↗

Results from a multi-laboratory ocean metaproteomic intercomparison: effects of LC-MS acquisition and data analysis procedures

Metaproteomics is an increasingly popular methodology that provides information regarding the metabolic functions of specific microbial taxa and has potential for contributing to ocean ecology and biogeochemical studies. A blinded multi-laboratory intercomparison was conducted to assess comparability and reproducibility of taxonomic and functional results and their sensitivity to methodological variables. Euphotic zone samples from the Bermuda Atlantic Time-series Study (BATS) in the North Atlantic Ocean collected by in situ pumps and the autonomous underwater vehicle (AUV) Clio were distributed with a paired metagenome, and one-dimensional (1D) liquid chromatographic data-dependent acquisition mass spectrometry analysis was stipulated. Analysis of mass spectra from seven laboratories through a common bioinformatic pipeline identified a shared set of 1056 proteins from 1395 shared peptide constituents. Quantitative analyses showed good reproducibility: pairwise regressions of spectral counts between laboratories yielded R 2 values averaged 0.62±0.11, and a Sørensen similarity analysis of the top 1000 proteins revealed 70 %–80 % similarity between laboratory groups. Taxonomic and functional assignments showed good coherence between technical replicates and different laboratories. A bioinformatic intercomparison study, involving 10 laboratories using eight software packages, successfully identified thousands of peptides within the complex metaproteomic datasets, demonstrating the utility of these software tools for ocean metaproteomic research. Lessons learned and potential improvements in methods were described. Future efforts could examine reproducibility in deeper metaproteomes, examine accuracy in targeted absolute quantitation analyses, and develop standards for data output formats to improve data interoperability. Together, these results demonstrate the reproducibility of metaproteomic analyses and their suitability for microbial oceanography research, including integration into global-scale ocean surveys and ocean biogeochemical models.

59 BASIC BIOLOGICAL SCIENCES↗

The SRG/eROSITA All-Sky Survey: Constraints on the structure growth from cluster number counts

Recent advancements in methods used in wide-area surveys have demonstrated the reliability of the number density of galaxy clusters as a viable tool for precision cosmology. Beyond testing the current cosmological paradigm, cluster number counts can also be used to investigate the discrepancies currently affecting cosmological measurements. In particular, cosmological studies based on cosmic shear and other large-scale structure probes routinely find a value for the amplitude of the fluctuations in the universe S​ 8 = σ 8 (Ω m /0.3) 0.5 smaller than the one inferred from the primary cosmic microwave background. In this work, we investigate this tension by measuring structure evolution across cosmic time as probed by the number counts of massive halos with the first SRG/eROSITA All-Sky Survey cluster catalog in the western Galactic hemisphere, complemented with the overlapping Dark Energy Survey Year-3, Kilo-Degree Survey, and Hyper Suprime-Cam data for weak lensing mass calibration, by implementing two different parameterizations and a model-agnostic method. In the first model, we measured the cosmic linear growth index as γ = 1.19 ± 0.21, which is in tension with the standard value of γ = 0.55 but in good statistical agreement with other large-scale structure probes. The second model is a phenomenological scenario in which we rescale the linear matter power spectrum at low redshift to investigate a potential reduction of structure formation, and it provided similar results. Finally, in a third strategy, we considered a standard ΛCDM cosmology, but we separated the cluster catalog into five redshift bins, measuring the cosmological parameters in each and inferring the evolution of the structure formation, finding hints of a reduction. Interestingly, the S ​8 value inferred from the number counts of the cluster eRASS1 when we add a degree of freedom to the matter power spectrum recovers the value inferred by cosmic shear studies. The observed reduction in the growth rate or systematic uncertainties associated with various measurements may account for the discrepancy in the S 8 ​ values suggested between cosmic shear probes and eROSITA cluster number counts and Planck CMB measurements.

cosmological parameters↗

Evaluation of Graph Analytics Frameworks Using the GAP Benchmark Suite

The analysis of connected data is an increasingly important application in high-performance computing. Such analyses can reveal fraudulent patterns in financial transactions, optimize telecommunications networks, predict information flow in social networks, etc. However, the landscape of graph analytics is highly diverse. Graph algorithms stress processor architectures differently, and no one graph can represent all topologies. Consequently, no single approach or framework is expected to be optimal for all graph analytics problems. To help make sense of this diverse landscape, we evaluated four approaches to graph analytics: GraphBLAS, Galois, BGL17, GraphIt; and compare them against hand-tuned implementations that take advantage of hardware features on our test platform. Graph- BLAS formulates graph analytics as sparse linear algebra. Galois provides syntactic constructs for data parallelism over irregular data structures. BGL17 is a generic C++ template library for implementing graph algorithms. GraphIt provides a domain- specific language to describe and optimize graph algorithms. We use the GAP Benchmark Suite to establish baseline performance and guide the side-by-side evaluation of each framework. GAP consists of 30 tests: six graph analytics algorithms (breadth- first search, single-source shortest path, PageRank, betweenness centrality, connected components, and triangle counting) run on five graphs, each with different topological characteristics (e.g., high diameter, skewed degree distribution, high average degree). High-performance reference implementations are included for each benchmark algorithm. Because a graph can be loaded into memory a number of ways (e.g., flat file on disk, compressed sparse format, data frames, retrieved from SQL or NoSQL databases), our evaluation focused on computational performance rather than I/O. Our results show the relative strengths of each framework.

Graph algorithms, Benchmarking, shared-memory prog↗

Type A Verification Report for the High Flux Beam Reactor Stack and Grounds, Brookhaven National Laboratory, Upton, New York

The U.S. Department of Energy (DOE) Order 458.1 requires independent verification (IV) of DOE cleanup projects (DOE 2011). The Oak Ridge Institute for Science and Education (ORISE) has been designated as the responsible organization for IV of the High Flux Beam Reactor (HFBR) Stack and Grounds area at Brookhaven National Laboratory (BNL) in Upton, New York. The IV evaluation may consist of an in-process inspection with document and data reviews (Type A Verification) or a confirmatory survey of the site (Type B Verification). DOE and ORISE determined that a Type A verification of the documents and data for the HFBR Stack and Grounds: Survey Units (SU) 6, 7, and 8 was appropriate based on the initial survey unit classification, the walkover surveys, and the final analytical results provided by the Brookhaven Science Associates (BSA). The HFBR Stack and Grounds surveys began in June 2011 and were completed in September 2011. Survey activities by BSA included gamma walkover scans and sampling of the as-left soils in accordance with the BSA Work Procedure (BNL 2010a). The Field Sampling Plan - Stack and Remaining HFBR Outside Areas (FSP) stated that gamma walk-over surveys would be conducted with a bare sodium iodide (NaI) detector, and a collimated detector would be used to check areas with elevated count rates to locate the source of the high readings (BNL 2010b). BSA used the Mult- Agency Radiation Survey and Site Investigation Manual (MARSSIM) principles for determining the classifications of each survey unit. Therefore, SUs 6 and 7 were identified as Class 1 and SU 8 was deemed Class 2 (BNL 2010b). Gamma walkover surveys of SUs 6, 7, and 8 were completed using a 2X2 NaI detector coupled to a data-logger with a global positioning system (GPS). The 100% scan surveys conducted prior to the final status survey (FSS) sampling identified two general soil areas and two isolated soil locations with elevated radioactivity. The general areas of elevated activity identified were investigated further with a collimated NaI detector. The uncollimated average gamma count rate was less than 15,000 counts per minute (cpm) for the SU 6, 7, and 8 composite area (BNL 2011a). Elevated count rates were observed in portions of each survey unit. The general areas of elevated counts near the Building 801 ventilation and operations and the entry to the Stack were determined to be directly related to the radioactive processes in those structures. To compensate for this radioactive shine, a collimated or shielded detector was used to lower the background count rate (BNL 2011b and c). This allowed the surveyor(s) to distinguish between background and actual radioactive contamination. Collimated gamma survey count rates in these shine affected areas were below 9,000 cpm (BNL 2011a). The average background count rate of 7,500 cpm was reported by BSA for uncollimated NaI detectors (BNL 2011d). The average collimated background ranged from 4,500-6,500 cpm in the westernmost part of SU 8 and from 2,000-3,500 cpm in all other areas (BNL 2011e). Based on these data, no further investigations were necessary for these general areas. SU 8 was the only survey unit that exhibited verified elevated radioactivity levels. The first of two isolated locations of elevated radioactivity had an uncollimated direct measurement of 50,000 cpm with an area background of 7,500 cpm (BNL 2011f). The second small area exhibiting elevated radiation levels was identified at a depth of 6 inches from the surface. The maximum reported count rate of 28,000 cpm was observed during scanning (BNL 2011g). The affected areas were remediated, and the contaminated soils were placed in an intermodal container for disposal. BSA's post-remediation walkover surveys were expanded to include a 10-foot radius around the excavated locations, and it was determined that further investigation was not required for these areas (BNL 2011 f and g). The post-remediation soil samples were collected and analyzed with onsite gamma spectroscopy equipment. These samples were also included with the FSS samples that were analyzed at an offsite facility for the primary radionuclides of concern (ROCs) (i.e., cesium-137, strontium-90, and radium-226). Analysis included full spectrum gamma spectroscopy for all samples. Sr-90 analysis was completed on all samples from SUs 6 and 7. However Sr-90 was only completed on the cores, composites, field blank and duplicate samples in SU 8. Alpha spectroscopy as well as liquid scintillation performed for tritium, carbon-14, and nickel-63 concentrations were completed on the composite samples from SUs 6 and 7. Various cores, composites, and samples from the remediated areas of SU 8 received alpha spectroscopy as well as liquid scintillation analyses for tritium, carbon-14, and nickel-63 to determine respective ROC concentrations (BNL 2011 h, i, and j). BSA submitted the FSS data and analytical results to demonstrate that remediation efforts complied with the specified cleanup goal of less than or equal to 15 millirem per year (mrem/yr) above background to a resident in 50 years (BNL 2011a through j). ORISE has reviewed the project documentation and FSS data for the HFBR Stack and Grounds: SUs 6, 7, and 8. The highest concentrations of the primary ROCs reported were 5.92 picocuries per gram (pCi/g) for Cs-137 and 2.03 pCi/g for Sr-90, with both ROCs having the qualifier for the sample result as less than the minimum detectable activity (MDA). For Ra-226, the highest detected concentration from the FSS data provided was 0.682 pCi/g. Other potential secondary contaminants were below their respective MDAs. Therefore, ORISE is of the opinion that BSA has provided sufficient evidence to demonstrate compliance with the 15 mrem/yr cleanup objectives for the final status survey data provided.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Data-Driven Model Validation Across Dimensions

Data-driven model validation across dimensions in mathematical and computational biology assumptions are often made (e.g., symmetry) to reduce the problem from three spatial dimensions (3D) to two (2D). However, some experimental datasets, such as cell counts obtained via flow cytometry, represent the entire 3D biological object. For purpose of model calibration and validation, it is sometimes necessary to compare these biological datasets with model outputs. In this work, we propose a methodology for scaling 2D model outputs to compare with 3D experimental datasets, and we discuss the application of this methodology to two examples: agent-based models of granuloma formation and skeletal muscle tissue. The accuracy of the method is evaluated in artificially generated scenarios.

97 MATHEMATICS AND COMPUTING↗

INNOVATIONS IN THE ANALYSIS OF CHANDRA-ACIS OBSERVATIONS

As members of the instrument team for the Advanced CCD Imaging Spectrometer (ACIS) on NASA's Chandra X-ray Observatory and as Chandra General Observers, we have developed a wide variety of data analysis methods that we believe are useful to the Chandra community, and have constructed a significant body of publicly available software (the ACIS Extract package) addressing important ACIS data and science analysis tasks. This paper seeks to describe these data analysis methods for two purposes: to document the data analysis work performed in our own science projects and to help other ACIS observers judge whether these methods may be useful in their own projects (regardless of what tools and procedures they choose to implement those methods). The ACIS data analysis recommendations we offer here address much of the workflow in a typical ACIS project, including data preparation, point source detection via both wavelet decomposition and image reconstruction, masking point sources, identification of diffuse structures, event extraction for both point and diffuse sources, merging extractions from multiple observations, nonparametric broadband photometry, analysis of low-count spectra, and automation of these tasks. Many of the innovations presented here arise from several, often interwoven, complications that are found in many Chandra projects: large numbers of point sources (hundreds to several thousand), faint point sources, misaligned multiple observations of an astronomical field, point source crowding, and scientifically relevant diffuse emission.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Videos, photos, and AI-derived grain size data associated with “High-throughput AI Video Surveys Enable Reproducible Multiscale Sediment Size Mapping, with Implications for Hydrobiogeochemical Parameterization”

NOTE: The manuscript associated with this data package is currently in review. The data may be revised based on reviewer feedback. Upon manuscript acceptance, this data package will be updated with the final dataset and additional metadata. This data package is associated with the manuscript “High-throughput AI Video Surveys Enable Reproducible Multiscale Sediment Size Mapping, with Implications for Hydrobiogeochemical Parameterization” under review. This data package includes five data types: 1) raw photos and videos from drone survey and walking smartphone surveys; 2) images derived from raw videos; 3) manual labeling of reference scales; 4) metadata for all images and photo resolution derived from artificial intelligence (AI) models or manual labels, 5) grain size data obtained from AI models for all photos, 6) metadata and grain size data after quality control, 7) summaries of sample efficiency for all data, and 8) computational fluid dynamics (CFD) data used to support hydro-biogeochemical (HBGC) parameter estimation. Such data is used to 1) demonstrate significant improvements in accuracy, efficiency, and quality control for grain size data collection with the help of AI models, 2) study the spatial heterogeneity of grain size and observation reproducibility based on tens of thousands of data points generated by the AI models, and 3) evaluate the impacts of grain size heterogeneity on key HBGC parameters across sediment-to-reach and hourly-to-yearly scales. In particular, the data package contains 116 folders and 179696 files. The files include 41 videos in .mov format, 64047 photos in .jpg format, 13541 video-derived photos in .png format, 12747 segmentation mask data in .tif format, 12747 segmentation data in .json format, 24771 .csv files that with metadata and grain size for each individual photo as well as water depth and velocity data from CFD and observation, 51791 .txt files of raw AI predicted labels, and 11 flight record data in .srt format. The summary for all metadata and grain size statistics information is included in “Scales_V3_NG.csv” and “Statistics_V3_NG.csv”. The summary for data that pass data quality control (QC) level 0-2 is included in “QCStatistics_V3_NG.csv”. The QC level 0 represents photos whose photo resolution is positive, excluding photos that miss reference scale. The QC level 1 means reference scale circularity uncertainty is less than 5% for smartphone images while representing photo resolution is larger than 0.44 mm/pixel for drone images. The QC level 2 means excluding photos whose grain number is less than 100, a minimum number of grains recommended by classic literature. The summary for each video’s name, length, frame rates, survey area, grain number, survey efficiency, etc. can be found in “QCSummary_V3_NG.csv”. The summary for site name, GPS coordinates, and number of images at each site can be found in “SitesSummary_V3_*.csv” files. Overall computational efficiency summary is reported in Table 4 of accompanying manuscript. Additionally, the nitrate concentration data used in this work was downloaded from an existing dataset published on ESS-DIVE (Boat-Dragged Sensor Hanford Reach.csv; Conner A. et al., 2020). We thank the United States Forest Service, Washington Department of Fish and Wildlife, Washington Department of Natural Resources, Cowiche Canyon Conservatory, Port of Benton, and the Confederated Tribes and Bands of the Yakama Nation for access to field locations where the data were collected. We also thank the Yakama Nation Tribal Council and Yakama Nation Fisheries for working with us to facilitate data collection and optimization of data usage according to their values and worldview.

54 ENVIRONMENTAL SCIENCES↗

MONITORING SHORT-TERM COSMIC-RAY SPECTRAL VARIATIONS USING NEUTRON MONITOR TIME-DELAY MEASUREMENTS

Neutron monitors (NMs) are ground-based detectors of cosmic-ray showers that are widely used for high-precision monitoring of changes in the Galactic cosmic-ray (GCR) flux due to solar storms and solar wind variations. In the present work, we show that a single neutron monitor station can also monitor short-term changes in the GCR spectrum, avoiding the systematic uncertainties in comparing data from different stations, by means of NM time-delay histograms. Using data for 2007–2014 from the Princess Sirindhorn Neutron Monitor, a station at Doi Inthanon, Thailand, with the world’s highest vertical geomagnetic cutoff rigidity of 16.8 GV, we have developed an analysis of time-delay histograms that removes the chance coincidences that can dominate conventional measures of multiplicity. We infer the “leader fraction” L of neutron counts that do not follow a previous neutron count in the same counter from the same atmospheric secondary, which is inversely related to the actual multiplicity and increases for increasing GCR spectral index. After correction for atmospheric pressure and water vapor, we find that L indicates substantial short-term GCR spectral hardening during some but not all Forbush decreases in GCR flux due to solar storms. Such spectral data from Doi Inthanon provide information about cosmic-ray energies beyond the Earth’s maximum geomagnetic cutoff, extending the reach of the worldwide NM network and opening a new avenue in the study of short-term GCR decreases.

79 ASTRONOMY AND ASTROPHYSICS↗

Passive neutron coincidence counting with plastic scintillators for the characterization of radioactive waste drums

The quantification of radioactive material is essential in the fields of safeguards, criticality control of nuclear processes, dismantling of nuclear facilities and components, or radioactive waste characterization. The Nuclear Measurement Laboratory (LMN) of CEA is involved in the development of time-correlated neutron detection techniques using plastic scintillators. Usually, 3He proportional counters are used for passive neutron coincidence counting owing to their high thermal neutron capture efficiency and gamma insensitivity. However, the global {sup 3}He shortage in the past few years has made these detectors extremely expensive. In addition, contrary to {sup 3}He counters for which a few tens of microseconds are needed to thermalize fast neutrons, in view to maximize the {sup 3}He(n,p){sup 3}H capture cross section, plastic scintillators are based on elastic scattering and therefore the light signal is formed within a few nanoseconds, correlated pulses being detected within a few dozen- or hundred nanoseconds. This time span reflects fission particles time of flight, which allows reducing accordingly the duration of the coincidence gate and thus the rate of random coincidences, which may totally blind fission coincidences when using {sup 3}He counters in case of a high (α,n) reaction rate. However, plastic scintillators are very sensitive to gamma rays, requiring the use of a thick metallic shield to reduce the corresponding background. Cross talk between detectors is also a major issue, which consists on the detection of one particle by several detectors due to elastic or inelastic scattering, leading to true but undesired coincidences. Data analysis algorithms are tested to minimize cross-talk in simultaneously activated detectors. The distinction between useful fission coincidences and the correlated background due to cross-talk, (α,n) and induced (n,2n) or (n,n'γ) reactions, is achieved by measuring 3-fold coincidences. The performances of a passive neutron coincidence counting system for radioactive waste drums using plastic scintillators have been studied using the Monte Carlo radiation transport code MCNPX-PoliMi v2.0 coupled to data processing algorithms developed with ROOT data analysis software. In addition to the correlated background, accidental coincidences are taken into account in the simulation by randomly merging pulses from different calculations with fission and (α,n) sources. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

BICEP2. II. Experiment and three-year data set

We report on the design and performance of the BICEP2 instrument and on its three-year data set. BICEP2 was designed to measure the polarization of the cosmic microwave background (CMB) on angular scales of 1°-5°(ℓ = 40-200), near the expected peak of the B-mode polarization signature of primordial gravitational waves from cosmic inflation. Measuring B-modes requires dramatic improvements in sensitivity combined with exquisite control of systematics. The BICEP2 telescope observed from the South Pole with a 26 cm aperture and cold, on-axis, refractive optics. BICEP2 also adopted a new detector design in which beam-defining slot antenna arrays couple to transition-edge sensor (TES) bolometers, all fabricated on a common substrate. The antenna-coupled TES detectors supported scalable fabrication and multiplexed readout that allowed BICEP2 to achieve a high detector count of 500 bolometers at 150 GHz, giving unprecedented sensitivity to B-modes at degree angular scales. After optimization of detector and readout parameters, BICEP2 achieved an instrument noise-equivalent temperature of 15.8 μK√s. The full data set reached Stokes Q and U map depths of 87.2 nK in square-degree pixels (5.'2 μK) over an effective area of 384 deg{sup 2} within a 1000 deg{sup 2} field. These are the deepest CMB polarization maps at degree angular scales to date. The power spectrum analysis presented in a companion paper has resulted in a significant detection of B-mode polarization at degree scales.

79 ASTRONOMY AND ASTROPHYSICS↗

ASCR Workshop Position Paper: Challenges and Opportunities in High Energy Physics

High energy particle physics and cosmology concern themselves with estimating fundamental parameters of nature, such as the masses and interactions of fundamental particles like the Higgs boson and the rate of expansion of the universe. In doing so, they analyze exabyte-scale datasets, some of the largest in all of science, and face many challenges in subsequent data analysis. These challenges are shared between the two disciplines, but we focus on particle physics to highlight one specific domain. In particle physics, the standard method for estimating parameters involves performing Monte Carlo (MC) integration as a function of both parameters of interest and nuisance parameters using an expensive simulator, counting the number of observed collision events (i.i.d. samples) from an experiment in the corresponding integration domains, and forming a Poisson likelihood function. This likelihood function is then used in a Frequentist manner to construct a maximum likelihood point estimate (MLE) and confidence set for the parameters. To sufficiently populate the high-dimensional integration domains, simulators consume billions of CPU-hours annually and produce hundreds of petabytes of intermediate output data. Several techniques have been developed to: optimize definitions of the integration domains so as to be maximally sensitive to a particular subset of parameters, efficiently estimate the integrals, and build robust surrogate models by interpolating between integral evaluations at different parameter points. One can view this whole endeavor as classical Simulation-Based Inference (SBI).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Concentration Independent Calibration of β-γ Coincidence Detector Using 131mXe and 133Xe

Absolute efficiency calibration of radiometric detectors is frequently difficult and requires careful detector modeling and accurate knowledge of the radioactive source used. In the past we have calibrated the b-g coincidence detector of the Automated Radioxenon Sampler/Analyzer (ARSA) using a variety of sources and techniques which have proven to be less than desirable.[1] A superior technique has been developed that uses the conversion-electron (CE) and x-ray coincidence of 131mXe to provide a more accurate absolute gamma efficiency of the detector. The 131mXe is injected directly into the beta cell of the coincident counting system and no knowledge of absolute source strength is required. In addition, 133Xe is used to provide a second independent means to obtain the absolute efficiency calibration. These two data points provide the necessary information for calculating the detector efficiency and can be used in conjunction with other noble gas isotopes to completely characterize and calibrate the ARSA nuclear detector. In this paper we discuss the techniques and results that we have obtained.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Dual particle imaging using time-of-flight neutron classification

Fast-neutron imaging technology is well-suited for passive nuclear material monitoring, secondary inspection of flagged cargo, and wide-area search for lost neutron sources. However, imaging systems that use pulse shape discrimination for event classification require complex pulse waveform analysis. In this work, we evaluate time-of-flight (TOF) based particle classification as an alternative solution for fast-neutron imaging by classifying all events with a TOF above a maximum threshold as neutrons. We measured a Cf-252 source next to Cs-137 using a 12-bar organic-glass scintillator array. By varying the TOF thresholds for neutron identification, we demonstrate a clear trade-off between event yield and backprojection image fidelity, with stricter thresholds improving precision at the cost of statistics, TOF thresholded data generated an image that predicted the neutron source direction with 20% reduced mean central angle prediction error compared to a traditional pulse shape discrimination (PSD) method with comparable event count. Time-of-flight particle classification shows promise as an alternative to pulse shape discrimination systems for fast neutron imaging systems looking to minimize costs and size of electronics with comparable imaging quality. The sources used demonstrate that the method is effective in classifying measured neutrons in a measurement environment with 150 μCi Cs-137 and 1.6 × 10 6 n/s Cf-252 sources positioned at distances of 66 cm and 81 cm from the detector. Additionally, the method classifies low-energy neutron events that pulse shape discrimination removes, so a combination of both methods would result in a higher overall neutron event efficiency.

Heriot, William [Univ. of Michigan, Ann Arbor, MI ↗