DETECTION OF THERMAL EMISSION FROM A SUPER-EARTH

We report on the detection of infrared light from the super-Earth 55 Cnc e, based on four occultations obtained with Warm Spitzer at 4.5 {mu}m. Our data analysis consists of a two-part process. In a first step, we perform individual analyses of each data set and compare several baseline models to optimally account for the systematics affecting each light curve. We apply independent photometric correction techniques, including polynomial detrending and pixel mapping, that yield consistent results at the 1{sigma} level. In a second step, we perform a global Markov Chain Monte Carlo analysis, including all four data sets that yield an occultation depth of 131 {+-} 28 ppm, translating to a brightness temperature of 2360 {+-} 300 K in the IRAC 4.5 {mu}m channel. This occultation depth suggests a low Bond albedo coupled to an inefficient heat transport from the planetary day side to the night side, or else possibly that the 4.5 {mu}m observations probe atmospheric layers that are hotter than the maximum equilibrium temperature (i.e., a thermal inversion layer or a deep hot layer). The measured occultation phase and duration are consistent with a circular orbit and improves the 3{sigma} upper limit on 55 Cnc e's orbital eccentricity from 0.25 to 0.06.

79 ASTRONOMY AND ASTROPHYSICS↗

Metal Angle Correction in the Cylinder Test

Cylinder test data shows that the copper wall angle increases with time in a given shot and becomes much larger if the wall is at half-thickness. The true velocity is suggested to be that perpendicular to the wall, and this brings full and half-wall data in closer agreement. The previously published Gurneytype equation for calculating the detonation energy density at each relative volume is modified by the angle of the wall and the angle of the measuring probe. This provides a unique solution to the energy density that does not require empirical coefficients or standards. We derive the length of the cone perpendicular to the cylinder surface and we use this as a description of the constant relative volume, creating a unified model for the first time. As a standard for full-wall cylinders, we obtain relative volumes of 2.43, 4.50 and 7.12 at the scaled wall displacements of 6, 12.5 and 19 mm. For a full-wall copper cylinder at the three points, the wall angles average 10.0, 11.0 and 11.6 degrees. Besides Cylinder test data on copper, previously unpublished framing camera pictures also measure angles for eight different metals. The angles are a function of wall thickness and relative volume but of nothing else, including the type of metal. For modeling, our simulation code calculates the wall velocity as seen along a particular probe direction, as this is a more realistic comparison to measurements than a zone particle velocity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Metal Angle Correction in the Cylinder Test

Cylinder test data shows that the copper wall angle increases with time in a given shot and becomes much larger if the wall is at half-thickness. The true velocity is suggested to be that perpendicular to the wall, and this brings full and half-wall data in closer agreement. The previously published Gurneytype equation for calculating the detonation energy density at each relative volume is modified by the angle of the wall and the angle of the measuring probe. This provides a unique solution to the energy density that does not require empirical coefficients or standards. We derive the length of the cone perpendicular to the cylinder surface and we use this as a description of the constant relative volume, creating a unified model for the first time. As a standard for full-wall cylinders, we obtain relative volumes of 2.43, 4.50 and 7.12 at the scaled wall displacements of 6, 12.5 and 19 mm. For a full-wall copper cylinder at the three points, the wall angles average 10.0, 11.0 and 11.6 degrees. Besides Cylinder test data on copper, previously unpublished framing camera pictures also measure angles for eight different metals. The angles are a function of wall thickness and relative volume but of nothing else, including the type of metal. For modeling, our simulation code calculates the wall velocity as seen along a particular probe direction, as this is a more realistic comparison to measurements than a zone particle velocity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Aperture effects on the oxygen abundance determinations from CALIFA data

This paper aims to provide aperture corrections for emission lines in a sample of spiral galaxies from the Calar Alto Legacy Integral Field Area Survey (CALIFA) database. In particular, we explore the behavior of the log([O iii] λ5007/Hβ)/([N ii] λ6583/Hα) (O3N2) and log[N ii] λ6583/Hα (N2) flux ratios since they are closely connected to different empirical calibrations of the oxygen abundances in star-forming galaxies. We compute the median growth curves of Hα, Hα/Hβ, O3N2, and N2 up to 2.5R {sub 50} and 1.5 disk R{sub eff}. These distances cover most of the optical spatial extent of the CALIFA galaxies. The growth curves simulate the effect of observing galaxies through apertures of varying radii. We split these growth curves by morphological types and stellar masses to check if there is any dependence on these properties. The median growth curve of the Hα flux shows a monotonous increase with radius with no strong dependence on galaxy inclination, morphological type, and stellar mass. The median growth curve of the Hα/Hβ ratio monotonically decreases from the center toward larger radii, showing for small apertures a maximum value of ≈10% larger than the integrated one. It does not show any dependence on inclination, morphological type, and stellar mass. The median growth curve of N2 shows a similar behavior, decreasing from the center toward larger radii. No strong dependence is seen on the inclination, morphological type, and stellar mass. Finally, the median growth curve of O3N2 increases monotonically with radius, and it does not show dependence on the inclination. However, at small radii it shows systematically higher values for galaxies of earlier morphological types and for high stellar mass galaxies. Applying our aperture corrections to a sample of galaxies from the SDSS survey at 0.02 ≤ z ≤ 0.3 shows that the average difference between fiber-based and aperture-corrected oxygen abundances, for different galaxy stellar mass and redshift ranges, reaches typically to ≈11%, depending on the abundance calibration used. This average difference is found to be systematically biased, though still within the typical uncertainties of oxygen abundances derived from empirical calibrations. Caution must be exercised when using observations of galaxies for small radii (e.g., below 0.5 R{sub eff}) given the high dispersion shown around the median growth curves. Thus, the application of these median aperture corrections to derive abundances for individual galaxies is not recommended when their fluxes come from radii much smaller than either R {sub 50} or R{sub eff}.

79 ASTRONOMY AND ASTROPHYSICS↗

Natural inflation: consistency with cosmic microwave background observations of Planck and BICEP2

Natural inflation is a good fit to all cosmic microwave background (CMB) data and may be the correct description of an early inflationary expansion of the Universe. The large angular scale CMB polarization experiment BICEP2 has announced a major discovery, which can be explained as the gravitational wave signature of inflation, at a level that matches predictions by natural inflation models. The natural inflation (NI) potential is theoretically exceptionally well motivated in that it is naturally flat due to shift symmetries, and in the simplest version takes the form V(φ) = Λ{sup 4} [1 ± cos(Nφ/f)]. A tensor-to-scalar ratio r > 0.1 as seen by BICEP2 requires the height of any inflationary potential to be comparable to the scale of grand unification and the width to be comparable to the Planck scale. The Cosine Natural Inflation model agrees with all cosmic microwave background measurements as long as f ≥ m{sub Pl} (where m{sub Pl} = 1.22 × 10{sup 19} GeV) and Λ ∼ m{sub GUT} ∼ 10{sup 16} GeV. This paper also discusses other variants of the natural inflation scenario: we show that axion monodromy with potential V∝ φ{sup 2/3} is inconsistent with the BICEP2 limits at the 95% confidence level, and low-scale inflation is strongly ruled out. Linear potentials V ∝ φ are inconsistent with the BICEP2 limit at the 95% confidence level, but are marginally consistent with a joint Planck/BICEP2 limit at 95%. We discuss the pseudo-Nambu Goldstone model proposed by Kinney and Mahanthappa as a concrete realization of low-scale inflation. While the low-scale limit of the model is inconsistent with the data, the large-field limit of the model is marginally consistent with BICEP2. All of the models considered predict negligible running of the scalar spectral index, and would be ruled out by a detection of running.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-G-IeP3-05: Effects of Image Receptor Technology and Dose Reduction Software On Radiation Dose Estimates for Fluoroscopically-Guided Interventional (FGI) Procedures

Purpose: To investigate the effects of image receptor technology and dose reduction software on radiation dose estimates for most frequently performed fluoroscopically-guided interventional (FGI) procedures at a tertiary health care center. Methods: IRB approval was obtained for retrospective analysis of FGI procedures performed in the interventional radiology suites between January-2011 and December-2015. This included procedures performed using image-intensifier (II) based systems which were subsequently replaced, flat-panel-detector (FPD) based systems which were later upgraded with ClarityIQ dose reduction software (Philips Healthcare) and relatively new FPD system already equipped with ClarityIQ. Post procedure, technologists entered system-reported cumulative air kerma (CAK) and kerma-area product (KAP; only KAP for II based systems) in RIS; these values were analyzed. Data pre-processing included correcting typographical errors and cross-verifying CAK and KAP. The most frequent high and low dose FGI procedures were identified and corresponding CAK and KAP values were compared. Results: Out of 27,251 procedures within this time period, most frequent high and low dose procedures were chemo/immuno-embolization (n=1967) and abscess drainage (n=1821). Mean KAP for embolization and abscess drainage procedures were 260,657, 310,304 and 94,908 mGycm{sup 2}, and 14,497, 15,040 and 6307 mGycm{sup 2} using II-, FPD- and FPD with ClarityIQ- based systems, respectively. Statistically significant differences were observed in KAP values for embolization procedures with respect to different systems but for abscess drainage procedures significant differences were only noted between systems with FPD and FPD with ClarityIQ (p<0.05). Mean CAK reduced significantly from 823 to 308 mGy and from 43 to 21 mGy for embolization and abscess drainage procedures, respectively, in transitioning to FPD systems with ClarityIQ (p<0.05). Conclusion: While transitioning from II- to FPD- based systems was not associated with dose reduction for the most frequently performed FGI procedures, substantial dose reduction was noted with relatively newer systems and dose reduction software.

60 APPLIED LIFE SCIENCES↗

Investigation of practical initial attenuation image estimates in TOF-MLAA reconstruction for PET/MR

Purpose: Time-of-flight joint attenuation and activity positron emission tomography reconstruction requires additional calibration (scale factors) or constraints during or post-reconstruction to produce a quantitative μ-map. In this work, the impact of various initializations of the joint reconstruction was investigated, and the initial average mu-value (IAM) method was introduced such that the forward-projection of the initial μ-map is already very close to that of the reference μ-map, thus reducing/minimizing the offset (scale factor) during the early iterations of the joint reconstruction. Consequently, the accuracy and efficiency of unconstrained joint reconstruction such as time-of-flight maximum likelihood estimation of attenuation and activity (TOF-MLAA) can be improved by the proposed IAM method. Methods: 2D simulations of brain and chest were used to evaluate TOF-MLAA with various initial estimates which include the object filled with water uniformly (conventional initial estimate), bone uniformly, the average μ-value uniformly (IAM magnitude initialization method), and the perfect spatial μ-distribution but with a wrong magnitude (initialization in terms of distribution). 3D GATE simulation was also performed for the chest phantom under a typical clinical scanning condition, and the simulated data were reconstructed with a fully corrected list-mode TOF-MLAA algorithm with various initial estimates. The accuracy of the average μ-values within the brain, chest, and abdomen regions obtained from the MR derived μ-maps was also evaluated using computed tomography μ-maps as the gold-standard. Results: The estimated μ-map with the initialization in terms of magnitude (i.e., average μ-value) was observed to reach the reference more quickly and naturally as compared to all other cases. Both 2D and 3D GATE simulations produced similar results, and it was observed that the proposed IAM approach can produce quantitative μ-map/emission when the corrections for physical effects such as scatter and randoms were included. The average μ-value obtained from MR derived μ-map was accurate within 5% with corrections for bone, fat, and uniform lungs. Conclusions: The proposed IAM-TOF-MLAA can produce quantitative μ-map without any calibration provided that there are sufficient counts in the measured data. For low count data, noise reduction and additional regularization/rescaling techniques need to be applied and investigated. The average μ-value within the object is prior information which can be extracted from MR and patient database, and it is feasible to obtain accurate average μ-value using MR derived μ-map with corrections as demonstrated in this work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Relativistic Douglas–Kroll–Hess calculations of hyperfine interactions within first-principles multireference methods

A relativistic magnetic hyperfine interaction Hamiltonian based on the Douglas–Kroll–Hess (DKH) theory up to the second order is implemented within the ab initio multireference methods, including spin–orbit coupling in the Molcas/OpenMolcas package. This implementation is applied to calculate relativistic hyperfine coupling (HFC) parameters for atomic systems and diatomic radicals with valence s or d orbitals by systematically varying active space size in the restricted active space self-consistent field formalism with restricted active space state interaction for spin–orbit coupling. The DKH relativistic treatment of the hyperfine interaction reduces the Fermi contact contribution to the HFC due to the presence of kinetic factors that regularize the singularity of the Dirac delta function in the nonrelativistic Fermi contact operator. This effect is more prominent for heavier nuclei. As the active space size increases, the relativistic correction of the Fermi contact contribution converges well to the experimental data for light and moderately heavy nuclei. The relativistic correction, however, does not significantly affect the spin-dipole contribution to the hyperfine interaction. In addition to the atomic and molecular systems, the implementation is applied to calculate the relativistic HFC parameters for large trivalent and divalent Tb-based single-molecule magnets (SMMs), such as Tb(III)Pc2 and Tb(II)(CpiPr5)2 without ligand truncation using well-converged basis sets. In particular, for the divalent SMM, which has an unpaired valence 6s/5d hybrid orbital, the relativistic treatment of HFC is crucial for a proper description of the Fermi contact contribution. Even with the relativistic hyperfine Hamiltonian, the divalent SMM is shown to exhibit strong tunability of HFC via an external electric field (i.e., strong hyperfine Stark effect).

Chemistry↗

A nonlinear lag correction algorithm for a-Si flat-panel x-ray detectors

Purpose: Detector lag, or residual signal, in a-Si flat-panel (FP) detectors can cause significant shading artifacts in cone-beam computed tomography reconstructions. To date, most correction models have assumed a linear, time-invariant (LTI) model and correct lag by deconvolution with an impulse response function (IRF). However, the lag correction is sensitive to both the exposure intensity and the technique used for determining the IRF. Even when the LTI correction that produces the minimum error is found, residual artifact remains. A new non-LTI method was developed to take into account the IRF measurement technique and exposure dependencies. Methods: First, a multiexponential (N = 4) LTI model was implemented for lag correction. Next, a non-LTI lag correction, known as the nonlinear consistent stored charge (NLCSC) method, was developed based on the LTI multiexponential method. It differs from other nonlinear lag correction algorithms in that it maintains a consistent estimate of the amount of charge stored in the FP and it does not require intimate knowledge of the semiconductor parameters specific to the FP. For the NLCSC method, all coefficients of the IRF are functions of exposure intensity. Another nonlinear lag correction method that only used an intensity weighting of the IRF was also compared. The correction algorithms were applied to step-response projection data and CT acquisitions of a large pelvic phantom and an acrylic head phantom. The authors collected rising and falling edge step-response data on a Varian 4030CB a-Si FP detector operating in dynamic gain mode at 15 fps at nine incident exposures (2.0%-92% of the detector saturation exposure). For projection data, 1st and 50th frame lag were measured before and after correction. For the CT reconstructions, five pairs of ROIs were defined and the maximum and mean signal differences within a pair were calculated for the different exposures and step-response edge techniques. Results: The LTI corrections left residual 1st and 50th frame lag up to 1.4% and 0.48%, while the NLCSC lag correction reduced 1st and 50th frame residual lags to less than 0.29% and 0.0052%. For CT reconstructions, the NLCSC lag correction gave an average error of 11 HU for the pelvic phantom and 3 HU for the head phantom, compared to 14-19 HU and 2-11 HU for the LTI corrections and 15 HU and 9 HU for the intensity weighted non-LTI algorithm. The maximum ROI error was always smallest for the NLCSC correction. The NLCSC correction was also superior to the intensity weighting algorithm. Conclusions: The NLCSC lag algorithm corrected for the exposure dependence of lag, provided superior image improvement for the pelvic phantom reconstruction, and gave similar results to the best case LTI results for the head phantom. The blurred ring artifact that is left over in the LTI corrections was better removed by the NLCSC correction in all cases.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deeply Virtual Pseudoscalar Meson Production with CLAS

One of the primary goals of the CLAS12 program is to double the Q 2 range of the available data into a region where approached with lower twist corrections become more reliable. Since the extraction of GPDs from electroproduction data can be difficult, a detailed understanding of the reaction mechanism is essential before one can compare with theoretical calculations. It is not yet clear at what values of Q 2 the application of GPDs to meson electroproduction becomes valid.1–5 However, detailed measurements of observables may test model-independent features of the reaction mechanism.

43 PARTICLE ACCELERATORS↗

W+n-Jet Predictions With MC@NLO in Sherpa

Results for the production of W-bosons in conjunction with up to three jets including parton shower corrections are presented and compared to recent LHC data. These results consistently incorporate the full next-to leading order QCD corrections through the MC{at}NLO method, as implemented in the SHERPA event generator, with the virtual corrections obtained from the BLACKHAT library.

43 PARTICLE ACCELERATORS↗

GFMC calculations of electromagnetic moments and M1 transitions in A {<=} 9 nuclei

We present recent Green's function Monte Carlo calculations of magnetic moments and M1 transitions in A{<=} 9 nuclei, which include corrections arising from two-body meson-exchange electromagnetic currents. Two-body effects provide significant corrections to the calculated observables, bringing them in excellent agreement with the experimental data. In particular, we find that two body corrections are especially large in the A = 9, T = 3/2 systems, in which they account for up to ~ 20% (~ 40%) of the total predicted value for the {sup 9}Li ({sup 9}C) magnetic moment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The CJ12 parton distributions

Three new sets of next-to-leading order parton distribution functions (PDFs) are presented, determined by global fits to a wide variety of data for hard scattering processes. The analysis includes target mass and higher twist corrections needed for the description of deep-inelastic scattering data at large x and low Q^2, and nuclear corrections for deuterium targets. The PDF sets correspond to three different models for the nuclear effects, and provide a more realistic uncertainty range for the d quark PDF compared with previous fits. Applications to weak boson production at colliders are also discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Update on Production Chemistry of the Roosevelt Hot Springs Reservoir

Analyses of production fluids from the Roosevelt Hot Springs reservoir were acquired from well sampling campaigns in 2015 and 2016. The resulting data have been recalculated to reservoir conditions by correcting for effects of steam loss, and the values are compared to legacy data from earlier reports to quantify changes with time in response to fluid production. The reservoir composition is similar to that at the start of reservoir exploitation, having near neutral pH, total dissolved solids of 7000-10,000 mg/kg, and ionic ratios of Cl/HCO3 ~50-100, Cl/SO4 ~50-100, and Na/K ~4-5. Cation, gas and silica geothermometers indicate a range of equilibration temperatures between 240 and 300 °C, but quartz-silica values are most closely consistent with measured reservoir temperatures and well enthalpies. The largest change in fluid composition is observed in well 54-3. The fluid has evolved from being fed by a single phase liquid to a twophase mixture of steam and liquid due to pressure draw down. The fluid also shows a 25% increase in reservoir chloride and a ~20° C decrement of cooling related to mixing with injected brine. The other production wells also show increase in chloride and decrease in temperature, but these changes diminish in magnitude with distance from injection well 14-2. Stable isotope compositions indicate that the reservoir water is largely meteoric in origin, having been modified by hydrothermal waterrock interaction. The water has also become progressively enriched in isotopic values in response to steam loss and mixing of injectate. N2-Ar-He and helium isotope ratios indicate a deep magmatic source region that probably supplies the heat for the hydrothermal system, consistent with recent Quaternary volcanism in the Mineral Mountains.

Simmons, Stuart↗

Corrective Action Decision Document/Corrective Action Plan for Corrective Action Unit 547: Miscellaneous Contaminated Waste Sites, Nevada National Security Site, Nevada, Revision 0

The purpose of this CADD/CAP is to present the corrective action alternatives (CAAs) evaluated for CAU 547, provide justification for selection of the recommended alternative, and describe the plan for implementing the selected alternative. Corrective Action Unit 547 consists of the following three corrective action sites (CASs): (1) CAS 02-37-02, Gas Sampling Assembly; (2) CAS 03-99-19, Gas Sampling Assembly; and(3) CAS 09-99-06, Gas Sampling Assembly. The gas sampling assemblies consist of inactive process piping, equipment, and instrumentation that were left in place after completion of underground safety experiments. The purpose of these safety experiments was to confirm that a nuclear explosion would not occur in the case of an accidental detonation of the high-explosive component of the device. The gas sampling assemblies allowed for the direct sampling of the gases and particulates produced by the safety experiments. Corrective Action Site 02-37-02 is located in Area 2 of the Nevada National Security Site (NNSS) and is associated with the Mullet safety experiment conducted in emplacement borehole U2ag on October 17, 1963. Corrective Action Site 03-99-19 is located in Area 3 of the NNSS and is associated with the Tejon safety experiment conducted in emplacement borehole U3cg on May 17, 1963. Corrective Action Site 09-99-06 is located in Area 9 of the NNSS and is associated with the Player safety experiment conducted in emplacement borehole U9cc on August 27, 1964. The CAU 547 CASs were investigated in accordance with the data quality objectives (DQOs) developed by representatives of the Nevada Division of Environmental Protection (NDEP) and the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office. The DQO process was used to identify and define the type, amount, and quality of data needed to determine and implement appropriate corrective actions for CAU 547. Existing radiological survey data and historical knowledge of the CASs were sufficient to meet the DQOs and evaluate CAAs without additional investigation. As a result, further investigation of the CAU 547 CASs was not required. The following CAAs were identified for the gas sampling assemblies: (1) clean closure, (2) closure in place, (3) modified closure in place, (4) no further action (with administrative controls), and (5) no further action. Based on the CAAs evaluation, the recommended corrective action for the three CASs in CAU 547 is closure in place. This corrective action will involve construction of a soil cover on top of the gas sampling assembly components and establishment of use restrictions at each site. The closure in place alternative was selected as the best and most appropriate corrective action for the CASs at CAU 547 based on the following factors: (1) Provides long-term protection of human health and the environment; (2) Minimizes short-term risk to site workers in implementing corrective action; (3) Is easily implemented using existing technology; (4) Complies with regulatory requirements; (5) Fulfills FFACO requirements for site closure; (6) Does not generate transuranic waste requiring offsite disposal; (7) Is consistent with anticipated future land use of the areas (i.e., testing and support activities); and (8) Is consistent with other NNSS site closures where contamination was left in place.

54 ENVIRONMENTAL SCIENCES↗

Direct Photon Production at Next-to–Next-to-Leading Order

Here, we present the first calculation of direct photon production at next-to-next-to leading order (NNLO) accuracy in QCD. For this process, although the final state cuts mandate only the presence of a single electroweak boson, the underlying kinematics resembles that of a generic vector boson plus jet topology. In order to regulate the infrared singularities present at this order we use the $N$-jettiness slicing procedure, applied for the first time to a final state that at Born level includes colored partons but no required jet. We compare our predictions to ATLAS 8 TeV data and find that the inclusion of the NNLO terms in the perturbative expansion, supplemented by electroweak corrections, provides an excellent description of the data with greatly reduced theoretical uncertainties.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Bias Correction in Urban Building Energy Modeling for Chicago Using Machine Learning

Urban-scale building energy modeling (UBEM) holds promise for optimizing energy usage across extensive geographic regions. However, there is a recognized bias between simulated energy consumption and actual measured data. This study, based on building data from Chicago, delved into bias correction techniques for enhancing the accuracy of UBEM energy consumption estimates. Initially, the AutoBEM simulation yielded a normalized mean bias error (NMBE) of 1.1% and 51% of Coefficient of the Variation of the Root Mean Square Error (CVRMSE) after outlier exclusion. To address this, three bias correction methods were deployed: Average Mean Bias Error based bias correction, Quantile mapping bias correction, and Machine learning-based bias correction using Linear Regression and Random Forest models. Post-correction results exhibited marked improvement. The NMBE values were diminished to 0 for Average MBE-based, 0.36 for Quantile Mapping, and 0 for Machine Learning-based corrections. Concurrently, the CVRMSE values registered reductions from an original 51 to 50.8 for Quantile Mapping, and 38.56 for Machine Learning-based corrections, pointing towards the effectiveness of specific bias correction methods in refining the precision of UBEM energy predictions. Such accurate estimations are paramount for informed energy planning and urban policy-making.

Chowdhury, Shovan↗