Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cavity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Evaluating the Effect of Vane Trailing Edge Flow on Turbine Rim Sealing

Abstract Modern gas turbine development continues to move toward increased overall efficiency, driven in part by higher firing temperatures that point to a need for more cooling air to prevent catastrophic component failure. However, using additional cooling flow bled from the upstream compressor causes a corresponding detriment to overall efficiency. A primary candidate for cooling flow optimization is purge flow, which contributes to sealing the stator–rotor cavity and prevents ingestion of hot main gas path (MGP) flow into the wheelspace. Previous research has identified that the external main gas path flow physics play a significant role in driving rim seal ingestion. However, the potential impact of other cooling flow features on ingestion behavior, such as vane trailing edge (VTE) flow, is absent in the open literature. This paper presents experimental measurements of rim cavity cooling effectiveness collected from a one-stage turbine operating at engine-representative Reynolds and Mach numbers. Carbon dioxide (CO2) was used as a tracer gas in both the purge flow and vane trailing edge flow to investigate flow migration into and out of the wheelspace. Results show that the vane trailing edge flow does in fact migrate into the rim seal and that there is a superposition relationship between individual cooling flow contributions. Computational fluid dynamics (CFD) simulations using unsteady Reynolds-averaged Navier–Stokes (URANS) were used to confirm VTE flow ingestion into the rim seal cavity. Radial and circumferential traverse surveys were performed to quantify cooling flow radial migration through the main gas path with and without vane trailing edge flow. The surveys confirmed that vane trailing edge flow is entrained into the wheelspace as purge flow is reduced. Local CO2 measurements also confirmed the presence of VTE flow deep in the wheelspace cavity.

Engineering↗

Use of Multiple Tracer Gases to Quantify Vane Trailing Edge Flow Into Turbine Rim Seals

Abstract Overlapping features are commonly used as rim seals between stationary and rotating components in a turbine stage. These rim seals are used to prevent main gas path ingestion to the wheelspace cavity, which reduces the lifespan of critical engine components such as the turbine disk. In addition to the overlapping features, purge flow, diverted from the compressor, is injected into the rim cavity to act as an airflow sealing mechanism. Previous research identified that in addition to the purge flow in the rim cavity, cooling flow from the vane trailing edge (VTE) is ingested into the rim seal cavity carrying the potential to cool components in the wheelspace. These previous findings, however, were not able to distinctly separate purge from VTE cooling flows, which is the contribution of this paper based on uniquely using two different tracer gases. A one-stage test turbine operating at engine-relevant conditions and consisting of real engine hardware was used to validate and quantify the ingestion of the VTE flow by independently seeding the purge and VTE flows with two different tracer gases. Experimental results show the presence of VTE flow in the rim seal throughout all purge flowrates evaluated. Circumferential variation of VTE flow was also studied both experimentally and computationally using a computational fluid dynamics model. Results showed that ingested VTE flow can reduce the detrimental effect of hot gas ingestion particularly at higher purge flowrates.

Engineering↗

Intermolecular vibrational energy transfer enabled by microcavity strong light–matter coupling

Selective vibrational energy transfer between molecules in the liquid phase, a difficult process hampered by weak intermolecular forces, is achieved through polaritons formed by strong coupling between cavity photon modes and donor and acceptor molecules. Using pump-probe and two-dimensional infrared spectroscopy, we found that the excitation of the upper polariton, which is composed mostly of donors, can efficiently relax to the acceptors within ~5 picoseconds. The energy-transfer efficiency can be further enhanced by increasing the cavity lifetime, suggesting that the energy transfer is a polaritonic process. This vibrational energy-transfer pathway opens doors for applications in remote chemistry, sensing mechanisms, and vibrational polariton condensation.

Science & Technology - Other Topics↗

Ultrafast quantum photonics enabled by coupling plasmonic nanocavities to strongly radiative antennas

Quantum emitters coupled to plasmonic nanostructures can act as exceptionally bright sources of single photons, operating at room temperature. Plasmonic mode volumes supported by these nanostructures can be several orders of magnitude smaller than the cubic wavelength, which leads to dramatically enhanced light–matter interactions and drastically increased photon production rates. However, when increasing the light localization further, these deeply subwavelength modes may in turn hinder the fast outcoupling of photons into free space. Plasmonic hybrid nanostructures combining a highly confined cavity mode and a larger antenna mode circumvent this issue. We establish the fundamental limits for quantum emission enhancement in such systems and find that the best performance is achieved when the cavity and antenna modes differ significantly in size. We experimentally support this idea by photomodifying a nanopatch antenna deterministically assembled around a nanodiamond known to contain a single nitrogen–vacancy (NV) center. As a result, the cavity mode shrinks, further shortening the NV fluorescence lifetime and increasing the single-photon brightness. Our analytical and numerical simulation results provide intuitive insight into the operation of these emitter–cavity–antenna systems and show that this approach could lead to single-photon sources with emission rates up to hundreds of THz and efficiencies close to unity.

47 OTHER INSTRUMENTATION↗

Strain-concentration for fast, compact photonic modulation and non-volatile memory

A critical figure of merit (FoM) for electro-optic (EO) modulators is the transmission change per voltage, d T / d V . Conventional approaches in wave-guided modulators maximize d T / d V via a high EO coefficient or longer light-material interaction lengths but are ultimately limited by material losses and nonlinearities. Optical and RF resonances improve d T / d V at the cost of spectral non-uniformity, especially for high- Q optical cavity resonances. Here, we introduce an EO modulator based on piezo-strain-concentration of a photonic crystal cavity to address both trade-offs: (i) it eliminates the trade-off between d T / d V and waveguide loss—i.e., enhancement of the resonance tuning efficiency d v c / d V for the fixed EO coefficient, waveguide length, and cavity Q —and (ii) at high DC strains it exhibits a non-volatile (NV) cavity tuning Δ v c ,NV for passive memory and programming of multiple devices into resonance despite fabrication variations. The device is fabricated on a scalable silicon nitride-on-aluminum nitride platform. We measure d v c / d V =177±1MHz/V, corresponding to Δ v c =40±0.32GHz for a voltage spanning ±120V with an energy consumption of δ U /Δ v c =0.17nW/GHz. The modulation bandwidth is flat up to ω BW,3dB /2 π =3.2±0.07MHz for broadband DC-AC and 142±17MHz for resonant operation near a 2.8 GHz mechanical resonance. Optical extinction up to 25 dB is obtained via Fano-type interference. Strain-induced beam-buckling modes are programmable under a “read-write” protocol with a continuous, repeatable tuning range of 5±0.25GHz, allowing for storage and retrieval, which we quantify with mutual information of 2.4 bits and a maximum non-volatile excursion of 8 GHz. Using a full piezo-optical finite-element-model (FEM) we identify key design principles for optimizing strain-based modulators and chart a path towards achieving performance comparable to lithium niobate-based modulators and the study of high strain physics on-chip.

Wen, Y. Henry (ORCID:0009000685423628)↗

Overcoming the fundamental limit of quantum transduction via intraband entanglement

A quantum transducer converts an input signal to an output probe at a distant frequency band while maintaining the quantum information with high fidelity, which is crucial for quantum networking and distributed quantum sensing and computing. In terms of microwave–optical quantum transduction, the state-of-the-art quantum transducers suffer low transduction efficiency from weak nonlinear coupling, wherein increasing pump power to enhance efficiency inevitably leads to thermal noise from heating. Moreover, we reveal that the efficiency-bandwidth product of a cavity electro-optical or electro-optomechanical transducer is fundamentally limited by pump power and nonlinear coupling coefficient, irrespective of cavity engineering efforts. To overcome this fundamental limit, we propose to noiselessly boost the transduction efficiency by consuming intraband entanglement (e.g., microwave–microwave or optical–optical entanglement in the case of microwave–optical transduction). Via a squeezer–coupler–antisqueezer sandwich structure, the protocol enhances the transduction efficiency to unity in the ideal lossless case, given an arbitrarily weak pump and nonlinear coupling. In practical cavity systems, our entanglement-assisted protocol surpasses the non-assisted fundamental limit of the efficiency-bandwidth product and reduces the threshold cooperativity for positive quantum capacity by a factor proportional to two-mode squeezing gain. Given a fixed cooperativity, our approach increases the broadband quantum capacity by orders of magnitude. The entanglement-assisted advantage is robust to ancilla loss and cavity detuning.

Shi, Haowei [Southern California U.] (ORCID:000000↗

Built-in Thermionic Electron Source for an SRF Linacs

The design of a thermionic electron source connected directly to a superconducting cavity, the key part of an SRF gun, is described. The results of beam dynamics optimization are presented which allow lack of beam current intercepting in the superconducting cavity. The electron source concept is presented including the cathode-grid assembly, thermal insulation of the cathode from the cavity, and the gun resonator design. The cavity thermal load caused by the gun is analyzed including the static heat load, black body radiation, backward electron heating, etc.

43 PARTICLE ACCELERATORS↗

Beam Dynamics Study in a Dual Energy Storage Ring for Ion Beam Cooling

A dual energy storage ring designed for beam cooling consists of two closed rings with significantly different energies: the cooling and damping rings. These two rings are connected by an energy recovering superconducting RF structure that provides the necessary energy difference. In our design, the RF acceleration has a main linac and harmonic cavities both running at crest that at first accelerates the beam from low energy E_{L} to high energy E_{H} and then decelerates the beam from E_{H} to E_{L} in the next pass. The purpose of the harmonic cavities is to extend the bunch length in a dual energy storage ring as such a longer bunch length may be very useful in a cooling application. Besides these cavities, a bunching cavity running on zero-crossing phase is used outside of the common beamline to provide the necessary longitudinal focusing for the system. In this paper, we present a preliminary lattice design along with the fundamental beam dynamics study in such a dual energy storage ring.

Dhital, B.↗

Developments Towards FRIB Upgrade to 400 MeV/u for Heaviest Uranium Ions

High-Q₀ medium-velocity (beta opt = 0.6) 5-cell elliptical cavities for superconducting linacs are critical technology for advancing current and future projects such as the Proton Improvement Plan II linac and the proposed energy upgrade of Michigan State University’s Facility For Rare Isotope Beams linac, FRIB400. Previous work established the validity of the novel geometry of the FRIB400 prototype 644 MHz 5-cell elliptical β = 0.65 cavities for future high Q₀ development. In collaboration with FNAL, two leading-edge high-Q₀ recipes, N-doping and Mid-T baking, were tested in the 5-cell format. 2/0 N-doping + cold electropolishing was successful at achieving FRIB400 and PIP-II Q₀ requirements, achieving an unprecedented 3.8 x 10¹⁰ at 17.5 MV/m, satisfying the FRIB400 Q₀ requirements by 1.75 times in a low-gauss environment. Mid-T baking exceeded FRIB400 Q₀ requirements by 1.4 times, and benefitted from decreased residual resistance compared to the N-doped cavity test. Systematic ultrasonic thickness measurements in single-cell revealed bulk (150 microns) EP with the modified EP tool is consistent across the inner surfaces of the cavity walls.

43 PARTICLE ACCELERATORS↗

First SELAP Algorithm Operational Experience of the New LLRF 3.0 RF Control System

The JLAB LLRF 3.0 system has been developed and is replacing the 30-year-old LLRF systems in the CEBAF accelerator. The LLRF system builds upon 25 years of design and operational RF control experience (digital and analog), and our recent collaboration in the design of the LCLSII LLRF system. The new system also incorporates a cavity control algorithm using a fully functional phase and amplitude locked Self Exciting Loop (SELAP). The first system (controlling 8 cavities) was installed and commissioned in August of 2021. Since then the new LLRF system has been operating with cavity gradients up to 20 MV/m, and electron beam currents up to 350 uA. This paper discusses the operational experience of the LLRF 3.0 SELAP algorithm along with other software and firmware tools like cavity and klystron characterization and quench detection.

Plawski, T. E.↗

Performance of PIP-II high-beta 650 cryomodule after transatlantic shipping

After shipment to the Daresbury Lab and return to Fermilab, the prototype HB650 cryomodule underwent another phase of 2K RF testing to ascertain any performance issues that may have arisen from the transport of the cryomodule. While measurements taken at room temperature after the conclusion of shipment indicated that there were no negative impacts on cavity alignment, beamline vacuum, or cavity frequency, testing at 2K was required to validate other aspects such as tuner operation, cavity coupling, cryogenic system integrity, and cavity performance. Results of this latest round of limited 2K testing will be presented.

43 PARTICLE ACCELERATORS↗

Nb$^{3}$Sn Technology for Low-beta linacs

Nb3Sn is the most advanced potential successor for niobium in superconducting RF accelerator cavities. Nb3Sn has a significantly higher critical temperature (18.3 K) compared to that of niobium (9.2 K). This has a large effect on the BCS surface resistance, and therefore, on the dynamic RF losses at 4.5 K. The higher critical temperature allows two important changes for cavity and cryomodule design. First, the lower BCS losses allow the designer to use a higher frequency, translating to physically smaller cavities and cryomodules. Second, the low dynamic losses allow the use of stand-alone cryocoolers instead of complex helium refrigerators and distribution systems. Fabrication of a prototype 218 MHz cavity, test results, and continuing challenges are discussed.

43 PARTICLE ACCELERATORS↗

Simulations of field emitters and multipacting in PIP-II Single Spoke Resonator Type-2

It has been found in benchmark tests that some Single Spoke Resonator Type-2 (SSR2) cavities have early field emission onset as well as strong multipacting barriers. A longstanding hypothesis is that field-emitted electrons in the high electric field accelerating gap can migrate and ignite multipacting bands in the low electric field regions of the cavity periphery. In this study, we use simulation techniques to examine multipacting behavior in SSR2 cavities from electrons seeded in common field emitter locations. Additionally, we investigated seed locations for areas in SSR2 cavities which may have poor coverage during high pressure water rinsing and compared the multipacting behavior.

43 PARTICLE ACCELERATORS↗

Microphonics Studies at STC in Fermilab

The spoke test cryostat is used to qualify the 325 MHz single spoke resonators at Fermilab (FNAL). During these tests a large detuning on the cavity was observed. The data acquisition for continuous captures were based on measurements from the piezoelectric actuators. A com-parison of the cavity vibrations measured with RF signal from the cavity and piezoelectric actuator signals are shown. The effects of microphonics on the cavity are discussed.

43 PARTICLE ACCELERATORS↗

Studies on the Fundamental Mechanisms of Niobium Electropolishing

To improve the superconducting performance of niobium SRF cavities, electropolishing (EP) with a sulfuric and hydroflouric acid mixture is used. The chemistry of this reaction is complex due to the interactions between diffusion mechanisms, surface oxide structure, and multiple chemical species. Past studies on the EP process have produced a certain set of optimum parameters that have been used successfully for a long time. However, two recent developments have called the efficacy of the existing EP process into question. Since the introduction of nitrogen doping the surface quality of some cavities has been very poor. Also, EP performed at colder than standard temperatures leads to an increase in the cavity performance. To understand these questions, we perform a multivariate study on the EP process using niobium test samples electropolished at different temperatures and potentials. We find that electropolishing at lower potentials leads to rough surface features such as pitting and grain etching. Some of the surface features show similarities to features seen in niobium cavities. The effect of electropolishing temperature is not clear based on the results of this study.

43 PARTICLE ACCELERATORS↗

3rd harmonic magnetometry assessment of NbTiN-based SIS structures

In the quest for alternative superconducting materials to bring accelerator cavity performance beyond the bulk niobium (Nb) intrinsic limits, a promising concept proposes that superconductor-insulator-superconductor (SIS) thin film structures can delay magnetic flux penetration in accelerator cavities to higher fields [1]. NbTiN is a candidate superconductor for such structures. We have demonstrated high quality NbTiN and AlN deposited by reactive direct current magnetron sputtering (DCMS), both for individual layers and multilayers. Interface quality has been assessed for bi-layer stacks with various NbTiN and AlN thicknesses from 500 and 30 nm down to 3 and 1 nm. These SIS structures show continued sharp interfaces. The Hfp enhancement of the films was examined with 3rd harmonic magnetometry. The system was designed and built in an ongoing collaboration with CEA Saclay. It can measure 1? to 2? samples on a temperature controlled stage. This contribution presents the assessment of the first penetration field enhancement with 3rd harmonic magnetometry for standalone films and multilayer nanostructures.

Valente, Anne-Marie↗

Managing Sn-Supply to Tune Surface Characteristics of Vapor-Diffusion Coating of Nb₃Sn

Nb₃Sn promises better RF performance (Q and E_{acc}) than niobium at any given temperature because of superior superconducting properties. Nb₃Sn-coated SRF cavities are now produced routinely by growing a few microns thick Nb₃Sn films inside Nb cavities via the tin vapor diffusion technique. Sn evaporation and consumption during the growth process notably affect the quality of the coating. Aiming at favorable surface characteristics that could enhance the RF performance, many coatings were produced by varying Sn sources and temperature profiles. Coupon samples were examined using different material characterization techniques, and a selected few sets of coating parameters were used to coat 1.3 GHz single-cell cavities for RF testing. The Sn supply’s careful tuning is essential to manage the microstructure, roughness, and overall surface characteristics of the coating. We summarize the material analysis of witness samples and discuss the performance of several Nb₃Sn-coated single-cell cavities linked to Sn-source characteristics and observed Sn consumption during the film growth process.

Pudasaini, U.↗

Microphonics in the LCLS-II Superconducting Linac

The LCLS-II project has installed a new superconducting linac at SLAC that consists of 35 1.3 GHz cryomodules and 2 3.9 GHz cryomodules. The linac will provide a 4 GeV electron beam for generating soft and hard X-ray pulses. Cavity detuning induced by microphonics was a significant design challenge for the LCLS-II cryomodules. Cryomodules were produced that were within the detuning specification (10 Hz for 1.3 GHz cryomodules) on test stands. Here we present first measurements of the microphonics in the installed LCLS-II superconducting linac. Overall, the microphonics in the linac are manageable with 94% of cavities coming within the detune specification. Only two cavities are gradient limited due to microphonics. We identify a leaking cool down valve as the source of microphonics limiting those two cavities.

43 PARTICLE ACCELERATORS↗